EATON-EPDU-MIB

File: EATON-EPDU-MIB.mib (81595 bytes)

Imported modules

SNMPv2-SMI SNMPv2-CONF SNMPv2-TC
EATON-OIDS

Imported symbols

OBJECT-TYPE NOTIFICATION-TYPE MODULE-IDENTITY
Counter32 Unsigned32 Integer32
NOTIFICATION-GROUP OBJECT-GROUP MODULE-COMPLIANCE
TEXTUAL-CONVENTION DateAndTime DisplayString
pduAgent

Defined Types

UnixTimeStamp  
Unix time stamp. Measured in seconds since January 1, 1970.
TEXTUAL-CONVENTION    
  Counter32  

UnitEntry  
SEQUENCE    
  strappingIndex Integer32
  productName OCTET STRING
  partNumber OCTET STRING
  serialNumber OCTET STRING
  firmwareVersion OCTET STRING
  unitName OCTET STRING
  lcdControl INTEGER
  clockValue DateAndTime
  temperatureScale INTEGER
  unitType INTEGER
  inputCount Integer32
  groupCount Integer32
  outletCount Integer32
  temperatureCount Integer32
  humidityCount Integer32
  contactCount Integer32
  communicationStatus INTEGER
  internalStatus INTEGER
  strappingStatus INTEGER
  userName OCTET STRING
  commInterface INTEGER

UnitControlEntry  
SEQUENCE    
  unitControlOffCmd Integer32
  unitControlOnCmd Integer32

InputEntry  
SEQUENCE    
  inputIndex Integer32
  inputType INTEGER
  inputFrequency Integer32
  inputFrequencyStatus INTEGER
  inputVoltageCount Integer32
  inputCurrentCount Integer32
  inputPowerCount Integer32
  inputPlugType INTEGER

InputVoltageEntry  
SEQUENCE    
  inputVoltageIndex Integer32
  inputVoltageMeasType INTEGER
  inputVoltage Integer32
  inputVoltageThStatus INTEGER
  inputVoltageThLowerWarning Integer32
  inputVoltageThLowerCritical Integer32
  inputVoltageThUpperWarning Integer32
  inputVoltageThUpperCritical Integer32

InputCurrentEntry  
SEQUENCE    
  inputCurrentIndex Integer32
  inputCurrentMeasType INTEGER
  inputCurrentCapacity Integer32
  inputCurrent Integer32
  inputCurrentThStatus INTEGER
  inputCurrentThLowerWarning Integer32
  inputCurrentThLowerCritical Integer32
  inputCurrentThUpperWarning Integer32
  inputCurrentThUpperCritical Integer32
  inputCurrentCrestFactor Integer32
  inputCurrentPercentLoad Integer32

InputPowerEntry  
SEQUENCE    
  inputPowerIndex Integer32
  inputPowerMeasType INTEGER
  inputVA Integer32
  inputWatts Integer32
  inputWh Unsigned32
  inputWhTimer UnixTimeStamp
  inputPowerFactor Integer32
  inputVAR Integer32

InputTotalPowerEntry  
SEQUENCE    
  inputTotalVA Integer32
  inputTotalWatts Integer32
  inputTotalWh Unsigned32
  inputTotalWhTimer UnixTimeStamp
  inputTotalPowerFactor Integer32
  inputTotalVAR Integer32

GroupEntry  
SEQUENCE    
  groupIndex Integer32
  groupID DisplayString
  groupName OCTET STRING
  groupType INTEGER
  groupBreakerStatus INTEGER
  groupChildCount Integer32

GroupChildEntry  
SEQUENCE    
  groupChildIndex Integer32
  groupChildType INTEGER
  groupChildOID OBJECT IDENTIFIER

GroupVoltageEntry  
SEQUENCE    
  groupVoltageMeasType INTEGER
  groupVoltage Integer32
  groupVoltageThStatus INTEGER
  groupVoltageThLowerWarning Integer32
  groupVoltageThLowerCritical Integer32
  groupVoltageThUpperWarning Integer32
  groupVoltageThUpperCritical Integer32

GroupCurrentEntry  
SEQUENCE    
  groupCurrentCapacity Integer32
  groupCurrent Integer32
  groupCurrentThStatus INTEGER
  groupCurrentThLowerWarning Integer32
  groupCurrentThLowerCritical Integer32
  groupCurrentThUpperWarning Integer32
  groupCurrentThUpperCritical Integer32
  groupCurrentCrestFactor Integer32
  groupCurrentPercentLoad Integer32

GroupPowerEntry  
SEQUENCE    
  groupVA Integer32
  groupWatts Integer32
  groupWh Unsigned32
  groupWhTimer UnixTimeStamp
  groupPowerFactor Integer32
  groupVAR Integer32

GroupControlEntry  
SEQUENCE    
  groupControlStatus INTEGER
  groupControlOffCmd Integer32
  groupControl0nCmd Integer32
  groupControlRebootCmd Integer32

OutletEntry  
SEQUENCE    
  outletIndex Integer32
  outletID DisplayString
  outletName OCTET STRING
  outletParentCount Integer32
  outletType INTEGER

OutletParentEntry  
SEQUENCE    
  outletParentIndex Integer32
  outletParentType INTEGER
  outletParentOID OBJECT IDENTIFIER

OutletVoltageEntry  
SEQUENCE    
  outletVoltage Integer32
  outletVoltageThStatus INTEGER
  outletVoltageThLowerWarning Integer32
  outletVoltageThLowerCritical Integer32
  outletVoltageThUpperWarning Integer32
  outletVoltageThUpperCritical Integer32

OutletCurrentEntry  
SEQUENCE    
  outletCurrentCapacity Integer32
  outletCurrent Integer32
  outletCurrentThStatus INTEGER
  outletCurrentThLowerWarning Integer32
  outletCurrentThLowerCritical Integer32
  outletCurrentThUpperWarning Integer32
  outletCurrentThUpperCritical Integer32
  outletCurrentCrestFactor Integer32
  outletCurrentPercentLoad Integer32

OutletPowerEntry  
SEQUENCE    
  outletVA Integer32
  outletWatts Integer32
  outletWh Unsigned32
  outletWhTimer UnixTimeStamp
  outletPowerFactor Integer32
  outletVAR Integer32

OutletControlEntry  
SEQUENCE    
  outletControlStatus INTEGER
  outletControlOffCmd Integer32
  outletControlOnCmd Integer32
  outletControlRebootCmd Integer32
  outletControlPowerOnState INTEGER
  outletControlSequenceDelay Integer32
  outletControlRebootOffTime Integer32
  outletControlSwitchable INTEGER
  outletControlShutoffDelay Integer32

TemperatureEntry  
SEQUENCE    
  temperatureIndex Integer32
  temperatureName OCTET STRING
  temperatureProbeStatus INTEGER
  temperatureValue Integer32
  temperatureThStatus INTEGER
  temperatureThLowerWarning Integer32
  temperatureThLowerCritical Integer32
  temperatureThUpperWarning Integer32
  temperatureThUpperCritical Integer32

HumidityEntry  
SEQUENCE    
  humidityIndex Integer32
  humidityName OCTET STRING
  humidityProbeStatus INTEGER
  humidityValue Integer32
  humidityThStatus INTEGER
  humidityThLowerWarning Integer32
  humidityThLowerCritical Integer32
  humidityThUpperWarning Integer32
  humidityThUpperCritical Integer32

ContactEntry  
SEQUENCE    
  contactIndex Integer32
  contactName OCTET STRING
  contactProbeStatus INTEGER
  contactState INTEGER

Defined Values

eatonEpdu 1.3.6.1.4.1.534.6.6.7
The MIB module for Eaton ePDUs (Enclosure Power Distribution Units).
MODULE-IDENTITY    

notifications 1.3.6.1.4.1.534.6.6.7.0
OBJECT IDENTIFIER    

units 1.3.6.1.4.1.534.6.6.7.1
OBJECT IDENTIFIER    

inputs 1.3.6.1.4.1.534.6.6.7.3
OBJECT IDENTIFIER    

groups 1.3.6.1.4.1.534.6.6.7.5
OBJECT IDENTIFIER    

outlets 1.3.6.1.4.1.534.6.6.7.6
OBJECT IDENTIFIER    

environmental 1.3.6.1.4.1.534.6.6.7.7
OBJECT IDENTIFIER    

conformance 1.3.6.1.4.1.534.6.6.7.25
OBJECT IDENTIFIER    

objectGroups 1.3.6.1.4.1.534.6.6.7.25.5
OBJECT IDENTIFIER    

notifyUserLogin 1.3.6.1.4.1.534.6.6.7.0.1
Sent whenever a user logs in.
Status: current Access: read-write
NOTIFICATION-TYPE    

notifyUserLogout 1.3.6.1.4.1.534.6.6.7.0.2
Sent whenever a user logs out.
Status: current Access: read-write
NOTIFICATION-TYPE    

notifyFailedLogin 1.3.6.1.4.1.534.6.6.7.0.3
Sent when someone attempts to log in and fails. On some models, may be sent after three failed login attempts.
Status: current Access: read-write
NOTIFICATION-TYPE    

notifyBootUp 1.3.6.1.4.1.534.6.6.7.0.4
Sent whenever an ePDU finishes booting up (hard or soft reboot).
Status: current Access: read-write
NOTIFICATION-TYPE    

notifyInputVoltageThStatus 1.3.6.1.4.1.534.6.6.7.0.11
Sent whenever an input voltage threshold status changes.
Status: current Access: read-write
NOTIFICATION-TYPE    

notifyInputCurrentThStatus 1.3.6.1.4.1.534.6.6.7.0.12
Sent whenever an input current threshold status changes.
Status: current Access: read-write
NOTIFICATION-TYPE    

notifyInputFrequencyStatus 1.3.6.1.4.1.534.6.6.7.0.13
Sent whenever the input frequency status changes.
Status: current Access: read-write
NOTIFICATION-TYPE    

notifyGroupVoltageThStatus 1.3.6.1.4.1.534.6.6.7.0.21
Sent whenever a group voltage threshold status changes.
Status: current Access: read-write
NOTIFICATION-TYPE    

notifyGroupCurrentThStatus 1.3.6.1.4.1.534.6.6.7.0.22
Sent whenever a group current threshold status changes.
Status: current Access: read-write
NOTIFICATION-TYPE    

notifyGroupBreakerStatus 1.3.6.1.4.1.534.6.6.7.0.23
Sent whenever a group status changes to indicate whether the circuit breaker is on or off.
Status: current Access: read-write
NOTIFICATION-TYPE    

notifyOutletVoltageThStatus 1.3.6.1.4.1.534.6.6.7.0.31
Sent whenever an outlet voltage threshold status changes.
Status: current Access: read-write
NOTIFICATION-TYPE    

notifyOutletCurrentThStatus 1.3.6.1.4.1.534.6.6.7.0.32
Sent whenever an outlet current threshold status changes.
Status: current Access: read-write
NOTIFICATION-TYPE    

notifyOutletControlStatus 1.3.6.1.4.1.534.6.6.7.0.33
Sent whenever an outlet state On / Off changes.
Status: current Access: read-write
NOTIFICATION-TYPE    

notifyTemperatureThStatus 1.3.6.1.4.1.534.6.6.7.0.41
Sent whenever a temperature threshold status changes.
Status: current Access: read-write
NOTIFICATION-TYPE    

notifyHumidityThStatus 1.3.6.1.4.1.534.6.6.7.0.42
Sent whenever a humidity threshold status changes.
Status: current Access: read-write
NOTIFICATION-TYPE    

notifyContactState 1.3.6.1.4.1.534.6.6.7.0.43
Sent whenever a contact sensor state changes.
Status: current Access: read-write
NOTIFICATION-TYPE    

notifyProbeStatus 1.3.6.1.4.1.534.6.6.7.0.44
Sent whenever the environment probe status changes.
Status: current Access: read-write
NOTIFICATION-TYPE    

notifyCommunicationStatus 1.3.6.1.4.1.534.6.6.7.0.51
Sent whenever the PDU communication status changes.
Status: current Access: read-write
NOTIFICATION-TYPE    

notifyInternalStatus 1.3.6.1.4.1.534.6.6.7.0.52
Sent whenever the PDU internal status changes.
Status: current Access: read-write
NOTIFICATION-TYPE    

notifyTest 1.3.6.1.4.1.534.6.6.7.0.53
Sent whenever the trap test feature is used by the communication card.
Status: current Access: read-write
NOTIFICATION-TYPE    

notifyStrappingStatus 1.3.6.1.4.1.534.6.6.7.0.54
Sent whenever the strapping communication status changes.
Status: current Access: read-write
NOTIFICATION-TYPE    

unitsPresent 1.3.6.1.4.1.534.6.6.7.1.1
Each unit is identified by a Strapping Index. This object returns a comma-delimited list of the Strapping Indexes of all units present in the strapping group. For example, if units 0, 1, 5, and 7 are present, this value will be '0,1,5,7'. For units that do not support strapping, a Strapping Index of '0' is assumed.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

unitTable 1.3.6.1.4.1.534.6.6.7.1.2
A list of units. In most cases this list will only contain one entry. However, some units have a 'strapping' feature which allow units to be daisy-chained together such that all of them can be accessed through the SNMP interface of the master. If strapping is enabled, the strapping indexes of the units that can be accessed will be listed in the unitsPresent object.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    UnitEntry

unitEntry 1.3.6.1.4.1.534.6.6.7.1.2.1
An entry for a PDU.
Status: current Access: not-accessible
OBJECT-TYPE    
  UnitEntry  

strappingIndex 1.3.6.1.4.1.534.6.6.7.1.2.1.1
For units that support 'strapping' functionality, this will be a unique value for each unit. If units do not support 'strapping', this will always be '0'.
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32 0..23  

productName 1.3.6.1.4.1.534.6.6.7.1.2.1.2
Name of the product.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(1..127)  

partNumber 1.3.6.1.4.1.534.6.6.7.1.2.1.3
Part number of the unit.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

serialNumber 1.3.6.1.4.1.534.6.6.7.1.2.1.4
Serial number of the unit.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

firmwareVersion 1.3.6.1.4.1.534.6.6.7.1.2.1.5
Firmware version.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

unitName 1.3.6.1.4.1.534.6.6.7.1.2.1.6
Descriptive name for the unit.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(1..63)  

lcdControl 1.3.6.1.4.1.534.6.6.7.1.2.1.7
Control the local LCD.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(0), lcdScreenOff(1), lcdKeyLock(2), lcdScreenOffAndKeyLock(3)  

clockValue 1.3.6.1.4.1.534.6.6.7.1.2.1.8
Clock value. This could be from either a real-time clock (in which case it is likely writeable) or from a time server via NTP (probably read-only).
Status: current Access: read-write
OBJECT-TYPE    
  DateAndTime  

temperatureScale 1.3.6.1.4.1.534.6.6.7.1.2.1.9
Scale used to return temperature objects.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER celsius(0), fahrenheit(1)  

unitType 1.3.6.1.4.1.534.6.6.7.1.2.1.10
Technical capabilities of the PDU. Functionality is as follows: Monitored (MI) - input and usually section/group monitoring. Advanced Monitored (AM) - input, section/group, and outlet monitoring. Switched (SW) - input and section/group monitoring, outlet switching. Managed (MA) - input, section/group, and outlet monitoring plug outlet switching.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER unknown(0), switched(1), advancedMonitored(2), managed(3), monitored(4)  

inputCount 1.3.6.1.4.1.534.6.6.7.1.2.1.20
Number of inputs on this ePDU.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

groupCount 1.3.6.1.4.1.534.6.6.7.1.2.1.21
Number of groups on this ePDU. Groups include breakers, outlet sections, and user-defined groups.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

outletCount 1.3.6.1.4.1.534.6.6.7.1.2.1.22
Number of outlets on this ePDU.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

temperatureCount 1.3.6.1.4.1.534.6.6.7.1.2.1.23
Max number of temperature measurements on this ePDU.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

humidityCount 1.3.6.1.4.1.534.6.6.7.1.2.1.24
Max number of humidity measurements on this ePDU.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

contactCount 1.3.6.1.4.1.534.6.6.7.1.2.1.25
Max number of contact sensors on this ePDU.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

communicationStatus 1.3.6.1.4.1.534.6.6.7.1.2.1.30
Status of the internal communication with the PDU.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER good(0), communicationLost(1)  

internalStatus 1.3.6.1.4.1.534.6.6.7.1.2.1.31
Status of the internal failure inside the PDU.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER good(0), internalFailure(1)  

strappingStatus 1.3.6.1.4.1.534.6.6.7.1.2.1.32
Status of the external communication with a strapping unit.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER good(0), communicationLost(1)  

userName 1.3.6.1.4.1.534.6.6.7.1.2.1.40
Username used to log into the PDU.
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  OCTET STRING Size(0..31)  

commInterface 1.3.6.1.4.1.534.6.6.7.1.2.1.41
Communications interface used to log into the PDU.
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  INTEGER serial(0), usb(1), telnet(2), web(3), ftp(4), xml(5)  

unitControlTable 1.3.6.1.4.1.534.6.6.7.1.3
A list of units that have controllable outlets.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    UnitControlEntry

unitControlEntry 1.3.6.1.4.1.534.6.6.7.1.3.1
An entry for a PDU which has controllable outlets.
Status: current Access: not-accessible
OBJECT-TYPE    
  UnitControlEntry  

unitControlOffCmd 1.3.6.1.4.1.534.6.6.7.1.3.1.2
Unit-level outlet control command. Once the command is issued, outlets will turn Off. 0-n : Time in seconds until the outlet Sequence Off command is issued -1 : Cancel a pending unit-level Off command When read, returns -1 if no command is pending, or the current downcount in seconds of a pending command. Certain ePDUs (mainly those with part numbers beginning with IPV or IPC) do not support delayed control commands. These will respond with an error if a command value of > 0 is written to this object.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 -1..99999  

unitControlOnCmd 1.3.6.1.4.1.534.6.6.7.1.3.1.3
Unit-level outlet control command. Once the command is issued, outlets will turn On according to their outletControlSequenceDelay value. 0-n : Time in seconds until the outlet Sequence On command is issued -1 : Cancel a pending unit-level On command When read, returns -1 if no command is pending, or the current downcount in seconds of a pending command. Certain ePDUs (mainly those with part numbers beginning with IPV or IPC) do not support delayed control commands. These will respond with an error if a command value of > 0 is written to this object.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 -1..99999  

inputTable 1.3.6.1.4.1.534.6.6.7.3.1
List of inputs to the PDU.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    InputEntry

inputEntry 1.3.6.1.4.1.534.6.6.7.3.1.1
An entry for a particular input.
Status: current Access: not-accessible
OBJECT-TYPE    
  InputEntry  

inputIndex 1.3.6.1.4.1.534.6.6.7.3.1.1.1
A unique value for each input. Its value ranges from 1 to inputCount.
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32 1..2  

inputType 1.3.6.1.4.1.534.6.6.7.3.1.1.2
Type of input - single phase, split phase, three phase delta, or three phase wye.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER singlePhase(1), splitPhase(2), threePhaseDelta(3), threePhaseWye(4)  

inputFrequency 1.3.6.1.4.1.534.6.6.7.3.1.1.3
Units are 0.1 Hz; divide by ten to get Hz.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

inputFrequencyStatus 1.3.6.1.4.1.534.6.6.7.3.1.1.4
Status of the measured input frequency relative to the nominal frequency and the admitted tolerance.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER good(0), outOfRange(1)  

inputVoltageCount 1.3.6.1.4.1.534.6.6.7.3.1.1.5
Number of input voltage measurements on this ePDU.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

inputCurrentCount 1.3.6.1.4.1.534.6.6.7.3.1.1.6
Number of input current measurements on this ePDU.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

inputPowerCount 1.3.6.1.4.1.534.6.6.7.3.1.1.7
Number of rows in the inputPowerTable.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

inputPlugType 1.3.6.1.4.1.534.6.6.7.3.1.1.8
Identifies which plug is on the input.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER other1Phase(100), other2Phase(200), other3Phase(300), iecC14Inlet(101), iecC20Inlet(102), iec316P6(103), iec332P6(104), iec360P6(105), iecC14Plug(106), iecC20Plug(107), nema515(120), nemaL515(121), nema520(122), nemaL520(123), nema615(124), nemaL615(125), nemaL530(126), nema620(127), nemaL620(128), nemaL630(129), cs8265(130), french(150), schuko(151), uk(152), nemaL1420(201), nemaL1430(202), iec516P6(301), iec460P9(302), iec560P9(303), iec532P6(304), iec563P6(306), nemaL1520(320), nemaL2120(321), nemaL1530(322), nemaL2130(323), cs8365(324), nemaL2220(325), nemaL2230(326), bladeUps208V(350), bladeUps400V(351)  

inputVoltageTable 1.3.6.1.4.1.534.6.6.7.3.2
A list of input voltage measurements. The number of entries is given by inputVoltageCount.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    InputVoltageEntry

inputVoltageEntry 1.3.6.1.4.1.534.6.6.7.3.2.1
An entry for a particular input voltage measurement.
Status: current Access: not-accessible
OBJECT-TYPE    
  InputVoltageEntry  

inputVoltageIndex 1.3.6.1.4.1.534.6.6.7.3.2.1.1
A unique value for each input voltage measurement. Its value ranges from 1 to inputVoltageCount.
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32 1..3  

inputVoltageMeasType 1.3.6.1.4.1.534.6.6.7.3.2.1.2
Value indicates what input voltage is being measured in this table row - single phase voltage, phase 1 to neutral, phase 2 to neutral, phase 3 to neutral, phase 1 to phase 2, phase 2 to phase 3, or phase 3 to phase 1.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER singlePhase(1), phase1toN(2), phase2toN(3), phase3toN(4), phase1to2(5), phase2to3(6), phase3to1(7)  

inputVoltage 1.3.6.1.4.1.534.6.6.7.3.2.1.3
An input voltage measurement value. Units are millivolts.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

inputVoltageThStatus 1.3.6.1.4.1.534.6.6.7.3.2.1.4
Status of the measured input voltage relative to the configured thresholds.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER good(0), lowWarning(1), lowCritical(2), highWarning(3), highCritical(4)  

inputVoltageThLowerWarning 1.3.6.1.4.1.534.6.6.7.3.2.1.5
Lower warning threshold. Units are millivolts. A negative value indicates that this object is not available.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 -1..500000  

inputVoltageThLowerCritical 1.3.6.1.4.1.534.6.6.7.3.2.1.6
Lower critical threshold. Units are millivolts. A negative value indicates that this object is not available.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 -1..500000  

inputVoltageThUpperWarning 1.3.6.1.4.1.534.6.6.7.3.2.1.7
Upper warning threshold. Units are millivolts. A negative value indicates that this object is not available.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 -1..500000  

inputVoltageThUpperCritical 1.3.6.1.4.1.534.6.6.7.3.2.1.8
Upper critical threshold. Units are millivolts. A negative value indicates that this object is not available.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 -1..500000  

inputCurrentTable 1.3.6.1.4.1.534.6.6.7.3.3
A list of input current measurements. The number of entries is given by inputCurrentCount.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    InputCurrentEntry

inputCurrentEntry 1.3.6.1.4.1.534.6.6.7.3.3.1
An entry for a particular input current measurement.
Status: current Access: not-accessible
OBJECT-TYPE    
  InputCurrentEntry  

inputCurrentIndex 1.3.6.1.4.1.534.6.6.7.3.3.1.1
A unique value for each input current measurement. Its value ranges from 1 to inputCurrentCount.
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32 1..4  

inputCurrentMeasType 1.3.6.1.4.1.534.6.6.7.3.3.1.2
Which input wire is being measured in this table row - single phase, neutral, phase 1, phase 2, or phase 3.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER singlePhase(1), neutral(2), phase1(3), phase2(4), phase3(5)  

inputCurrentCapacity 1.3.6.1.4.1.534.6.6.7.3.3.1.3
Rated current capacity of the input. A negative value indicates that the hardware current capacity is unknown. Units are milliamps.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

inputCurrent 1.3.6.1.4.1.534.6.6.7.3.3.1.4
An input current measurement value. Units are milliamps.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

inputCurrentThStatus 1.3.6.1.4.1.534.6.6.7.3.3.1.5
Status of the measured input current relative to the configured thresholds.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER good(0), lowWarning(1), lowCritical(2), highWarning(3), highCritical(4)  

inputCurrentThLowerWarning 1.3.6.1.4.1.534.6.6.7.3.3.1.6
Lower warning threshold. Units are milliamps. A negative value indicates that this object is not available.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 -1..100000  

inputCurrentThLowerCritical 1.3.6.1.4.1.534.6.6.7.3.3.1.7
Lower critical threshold. Units are milliamps. A negative value indicates that this object is not available.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 -1..100000  

inputCurrentThUpperWarning 1.3.6.1.4.1.534.6.6.7.3.3.1.8
Upper warning threshold. Units are milliamps. A negative value indicates that this object is not available.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 -1..100000  

inputCurrentThUpperCritical 1.3.6.1.4.1.534.6.6.7.3.3.1.9
Upper critical threshold. Units are milliamps. A negative value indicates that this object is not available.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 -1..100000  

inputCurrentCrestFactor 1.3.6.1.4.1.534.6.6.7.3.3.1.10
Current crest factor. Units are in milli, for example a crest factor of 1.414 will be returned as 1414. A negative value indicates that this object is not available.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

inputCurrentPercentLoad 1.3.6.1.4.1.534.6.6.7.3.3.1.11
Current percent load, based on the rated current capacity. Units are percentage, for example 80% will be returned as 80. A negative value indicates that this object is not available.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

inputPowerTable 1.3.6.1.4.1.534.6.6.7.3.4
A list of input power measurements. The number of entries is given by inputPowerCount.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    InputPowerEntry

inputPowerEntry 1.3.6.1.4.1.534.6.6.7.3.4.1
An entry for an input power measurement.
Status: current Access: not-accessible
OBJECT-TYPE    
  InputPowerEntry  

inputPowerIndex 1.3.6.1.4.1.534.6.6.7.3.4.1.1
A unique value for each input power measurement. Its value ranges from 1 to inputPowerCount.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 1..12  

inputPowerMeasType 1.3.6.1.4.1.534.6.6.7.3.4.1.2
Value indicates what is being measured in this table row.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER unknown(0), phase1(1), phase2(2), phase3(3), total(4)  

inputVA 1.3.6.1.4.1.534.6.6.7.3.4.1.3
An input VA value. Units are VA. A negative value indicates that this object is not available.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

inputWatts 1.3.6.1.4.1.534.6.6.7.3.4.1.4
An input Watts value. Units are Watts. A negative value indicates that this object is not available.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

inputWh 1.3.6.1.4.1.534.6.6.7.3.4.1.5
Units are Watt-hours. This object is writable so that it can be reset to 0. When it is written to, the inputWhTimer will be reset updated as well.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 0..4294967295  

inputWhTimer 1.3.6.1.4.1.534.6.6.7.3.4.1.6
Timestamp of when input Watt-hours (inputWh) was last reset.
Status: current Access: read-only
OBJECT-TYPE    
  UnixTimeStamp  

inputPowerFactor 1.3.6.1.4.1.534.6.6.7.3.4.1.7
An input PF value. Units are in thousandths, for example a power factor of 0.958 would be returned as 958, and 0.92 would be returned as 920. A negative value indicates that this object is not available.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

inputVAR 1.3.6.1.4.1.534.6.6.7.3.4.1.8
An input VAR value. Units are VAR. A negative value indicates that this object is not available.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

inputTotalPowerTable 1.3.6.1.4.1.534.6.6.7.3.5
A list of total input power measurements.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    InputTotalPowerEntry

inputTotalPowerEntry 1.3.6.1.4.1.534.6.6.7.3.5.1
An entry for a total input power measurement.
Status: current Access: not-accessible
OBJECT-TYPE    
  InputTotalPowerEntry  

inputTotalVA 1.3.6.1.4.1.534.6.6.7.3.5.1.3
An input VA value. Units are VA. A negative value indicates that this object is not available.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

inputTotalWatts 1.3.6.1.4.1.534.6.6.7.3.5.1.4
An input Watts value. Units are Watts. A negative value indicates that this object is not available.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

inputTotalWh 1.3.6.1.4.1.534.6.6.7.3.5.1.5
Units are Watt-hours. This object is writable so that it can be reset to 0. When it is written to, the inputWhTimer will be reset updated as well.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 0..4294967295  

inputTotalWhTimer 1.3.6.1.4.1.534.6.6.7.3.5.1.6
Timestamp of when input Watt-hours (inputWh) was last reset.
Status: current Access: read-only
OBJECT-TYPE    
  UnixTimeStamp  

inputTotalPowerFactor 1.3.6.1.4.1.534.6.6.7.3.5.1.7
An input PF value. Units are in thousandths, for example a power factor of 0.958 would be returned as 958, and 0.92 would be returned as 920. A negative value indicates that this object is not available.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

inputTotalVAR 1.3.6.1.4.1.534.6.6.7.3.5.1.8
An input VAR value. Units are VAR. A negative value indicates that this object is not available.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

groupTable 1.3.6.1.4.1.534.6.6.7.5.1
A list of groups. The number of entries is given by groupCount.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    GroupEntry

groupEntry 1.3.6.1.4.1.534.6.6.7.5.1.1
An entry for a particular group.
Status: current Access: not-accessible
OBJECT-TYPE    
  GroupEntry  

groupIndex 1.3.6.1.4.1.534.6.6.7.5.1.1.1
A unique value for each group. Its value ranges from 1 to groupCount.
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32 1..64  

groupID 1.3.6.1.4.1.534.6.6.7.5.1.1.2
Alphanumeric designator for the group. This value may be written on the face of the unit.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(2..4)  

groupName 1.3.6.1.4.1.534.6.6.7.5.1.1.3
A descriptive name for the group.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(1..31)  

groupType 1.3.6.1.4.1.534.6.6.7.5.1.1.4
The type of the group.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER unknown(0), breaker1pole(1), breaker2pole(2), breaker3pole(3), outletSection(4), userDefined(5)  

groupBreakerStatus 1.3.6.1.4.1.534.6.6.7.5.1.1.5
Only applicable to breaker-groups. Indicates whether a breaker is turned off or on.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER notApplicable(0), breakerOn(1), breakerOff(2)  

groupChildCount 1.3.6.1.4.1.534.6.6.7.5.1.1.6
Number of children for this group.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

groupChildTable 1.3.6.1.4.1.534.6.6.7.5.2
A list of children for this group. For example, this table will link to all of the outlets that are contained in a particular group.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    GroupChildEntry

groupChildEntry 1.3.6.1.4.1.534.6.6.7.5.2.1
An entry for a particular child.
Status: current Access: not-accessible
OBJECT-TYPE    
  GroupChildEntry  

groupChildIndex 1.3.6.1.4.1.534.6.6.7.5.2.1.1
A unique value for each child. Its value ranges from 1 to groupChildCount.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 1..32  

groupChildType 1.3.6.1.4.1.534.6.6.7.5.2.1.2
The type of the child.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER unknown(0), section(2), custom(3), outlet(4)  

groupChildOID 1.3.6.1.4.1.534.6.6.7.5.2.1.3
Object ID of a child object.
Status: current Access: read-only
OBJECT-TYPE    
  OBJECT IDENTIFIER  

groupVoltageTable 1.3.6.1.4.1.534.6.6.7.5.3
A list of group voltage measurements. There can be only one voltage measurement for each group.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    GroupVoltageEntry

groupVoltageEntry 1.3.6.1.4.1.534.6.6.7.5.3.1
An entry for a group voltage measurement.
Status: current Access: not-accessible
OBJECT-TYPE    
  GroupVoltageEntry  

groupVoltageMeasType 1.3.6.1.4.1.534.6.6.7.5.3.1.2
Value indicates what voltage is being measured in this table row.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER unknown(0), singlePhase(1), phase1toN(2), phase2toN(3), phase3toN(4), phase1to2(5), phase2to3(6), phase3to1(7)  

groupVoltage 1.3.6.1.4.1.534.6.6.7.5.3.1.3
Units are millivolts.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

groupVoltageThStatus 1.3.6.1.4.1.534.6.6.7.5.3.1.4
Status of the measured group voltage relative to the configured thresholds.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER good(0), lowWarning(1), lowCritical(2), highWarning(3), highCritical(4)  

groupVoltageThLowerWarning 1.3.6.1.4.1.534.6.6.7.5.3.1.5
Lower warning threshold. Units are millivolts. A negative value indicates that this object is not available.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 -1..500000  

groupVoltageThLowerCritical 1.3.6.1.4.1.534.6.6.7.5.3.1.6
Lower critical threshold. Units are millivolts. A negative value indicates that this object is not available.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 -1..500000  

groupVoltageThUpperWarning 1.3.6.1.4.1.534.6.6.7.5.3.1.7
Upper warning threshold. Units are millivolts. A negative value indicates that this object is not available.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 -1..500000  

groupVoltageThUpperCritical 1.3.6.1.4.1.534.6.6.7.5.3.1.8
Upper critical threshold. Units are millivolts. A negative value indicates that this object is not available.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 -1..500000  

groupCurrentTable 1.3.6.1.4.1.534.6.6.7.5.4
A list of group current measurements. There can be only one current measurement for each group.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    GroupCurrentEntry

groupCurrentEntry 1.3.6.1.4.1.534.6.6.7.5.4.1
An entry for a group current measurement.
Status: current Access: not-accessible
OBJECT-TYPE    
  GroupCurrentEntry  

groupCurrentCapacity 1.3.6.1.4.1.534.6.6.7.5.4.1.2
Rated current capacity of the group. Units are milliamps. A negative value indicates that the hardware current capacity is unknown (it will always be unknown for custom groups).
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

groupCurrent 1.3.6.1.4.1.534.6.6.7.5.4.1.3
A group current measurement value. Units are milliamps.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

groupCurrentThStatus 1.3.6.1.4.1.534.6.6.7.5.4.1.4
Status of the measured group current relative to the configured thresholds.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER good(0), lowWarning(1), lowCritical(2), highWarning(3), highCritical(4)  

groupCurrentThLowerWarning 1.3.6.1.4.1.534.6.6.7.5.4.1.5
Lower warning threshold. Units are milliamps. A negative value indicates that this object is not available.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 -1..100000  

groupCurrentThLowerCritical 1.3.6.1.4.1.534.6.6.7.5.4.1.6
Lower critical threshold. Units are milliamps. A negative value indicates that this object is not available.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 -1..100000  

groupCurrentThUpperWarning 1.3.6.1.4.1.534.6.6.7.5.4.1.7
Upper warning threshold. Units are milliamps. A negative value indicates that this object is not available.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 -1..100000  

groupCurrentThUpperCritical 1.3.6.1.4.1.534.6.6.7.5.4.1.8
Upper critical threshold. Units are milliamps. A negative value indicates that this object is not available.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 -1..100000  

groupCurrentCrestFactor 1.3.6.1.4.1.534.6.6.7.5.4.1.9
Current crest factor. Units are in milli, for example a crest factor of 1.414 will be returned as 1414. A negative value indicates that this object is not available.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

groupCurrentPercentLoad 1.3.6.1.4.1.534.6.6.7.5.4.1.10
Current percent load, based on the rated current capacity. Units are percentage, for example 80% will be returned as 80. A negative value indicates that this object is not available.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

groupPowerTable 1.3.6.1.4.1.534.6.6.7.5.5
A list of group power measurements. There can be only one power measurement for each group.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    GroupPowerEntry

groupPowerEntry 1.3.6.1.4.1.534.6.6.7.5.5.1
An entry for a group power measurement.
Status: current Access: not-accessible
OBJECT-TYPE    
  GroupPowerEntry  

groupVA 1.3.6.1.4.1.534.6.6.7.5.5.1.2
A group VA value. Units are VA. A negative value indicates that this object is not available.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

groupWatts 1.3.6.1.4.1.534.6.6.7.5.5.1.3
A group Watts value. Units are Watts. A negative value indicates that this object is not available.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

groupWh 1.3.6.1.4.1.534.6.6.7.5.5.1.4
Units are Watt-hours. This object is writable so that it can be reset to 0. When it is written to, the inputWhTotalTimer will be reset to 0 as well.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 0..4294967295  

groupWhTimer 1.3.6.1.4.1.534.6.6.7.5.5.1.5
Timestamp of when group Watt-hours (groupWh) was last reset.
Status: current Access: read-only
OBJECT-TYPE    
  UnixTimeStamp  

groupPowerFactor 1.3.6.1.4.1.534.6.6.7.5.5.1.6
A group PF value. Units are in thousandths, for example a power factor of 0.958 would be returned as 958, and 0.92 would be returned as 920. A negative value indicates that this object is not available.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

groupVAR 1.3.6.1.4.1.534.6.6.7.5.5.1.7
A group VAR value. Units are VAR. A negative value indicates that this object is not available.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

groupControlTable 1.3.6.1.4.1.534.6.6.7.5.6
A list of controllable groups.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    GroupControlEntry

groupControlEntry 1.3.6.1.4.1.534.6.6.7.5.6.1
An entry for a controllable group.
Status: current Access: not-accessible
OBJECT-TYPE    
  GroupControlEntry  

groupControlStatus 1.3.6.1.4.1.534.6.6.7.5.6.1.2
Current state of a controlled group. A value of 'mixed' means that that the outlets within the group have differing states.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER off(0), on(1), rebooting(2), mixed(3)  

groupControlOffCmd 1.3.6.1.4.1.534.6.6.7.5.6.1.3
Group-level outlet control command. Once the command is issued, the outlets in the group will turn Off immediately. 0-n : Time in seconds until the group command is issued -1 : Cancel a pending group-level Off command When read, returns -1 if no command is pending, or the current downcount in seconds of a pending command. Certain ePDUs (mainly those with part numbers beginning with IPV or IPC) do not support delayed control commands. These will respond with an error if a command value of > 0 is written to this object.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 -1..99999  

groupControl0nCmd 1.3.6.1.4.1.534.6.6.7.5.6.1.4
Group-level outlet control command. Once the command is issued, the outlets in the group will turn On immediately. 0-n : Time in seconds until the group command is issued -1 : Cancel a pending group-level On command When read, returns -1 if no command is pending, or the current downcount in seconds of a pending command. Certain ePDUs (mainly those with part numbers beginning with IPV or IPC) do not support delayed control commands. These will respond with an error if a command value of > 0 is written to this object.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 -1..99999  

groupControlRebootCmd 1.3.6.1.4.1.534.6.6.7.5.6.1.5
Group-level outlet control command. For outlets that are On prior to the Reboot command, they will switch Off immediately when the command is issued, remain Off for outletControlRebootOffTime seconds, and then turn back On. For outlets that are Off prior to the Reboot command, they will turn On after a delay of outletControlRebootOffTime seconds from when the command is issued. 0-n : Time in seconds until the Reboot command is issued -1 : Cancel a pending group-level Reboot command When read, returns -1 if no command is pending, or the current downcount in seconds of a pending command. Certain ePDUs (mainly those with part numbers beginning with IPV or IPC) do not support delayed control commands. These will respond with an error if a command value of > 0 is written to this object.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 -1..0  

outletTable 1.3.6.1.4.1.534.6.6.7.6.1
A list of outlets. The number of entries is given by outletCount.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    OutletEntry

outletEntry 1.3.6.1.4.1.534.6.6.7.6.1.1
An entry for a particular outlet.
Status: current Access: not-accessible
OBJECT-TYPE    
  OutletEntry  

outletIndex 1.3.6.1.4.1.534.6.6.7.6.1.1.1
A unique value for each outlet. its value ranges from 1 to outletCount.
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32 1..64  

outletID 1.3.6.1.4.1.534.6.6.7.6.1.1.2
Alphanumeric designator for the outlet.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(2..4)  

outletName 1.3.6.1.4.1.534.6.6.7.6.1.1.3
A descriptive name for the outlet.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(1..31)  

outletParentCount 1.3.6.1.4.1.534.6.6.7.6.1.1.4
Number of parents for this outlet.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

outletType 1.3.6.1.4.1.534.6.6.7.6.1.1.5
The physical type of outlet.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER unknown(0), iecC13(1), iecC19(2), uk(10), french(11), schuko(12), nema515(20), nema51520(21), nema520(22), nemaL520(23), nemaL530(24), nema615(25), nema620(26), nemaL620(27), nemaL630(28), nemaL715(29), rf203p277(30)  

outletParentTable 1.3.6.1.4.1.534.6.6.7.6.2
A list of parents for this outlet. For example, this table will link to all of the groups that have this outlet as a child.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    OutletParentEntry

outletParentEntry 1.3.6.1.4.1.534.6.6.7.6.2.1
An entry for a particular parent.
Status: current Access: not-accessible
OBJECT-TYPE    
  OutletParentEntry  

outletParentIndex 1.3.6.1.4.1.534.6.6.7.6.2.1.1
A unique value for each parent. Its value ranges from 1 to outletParentCount.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 1..32  

outletParentType 1.3.6.1.4.1.534.6.6.7.6.2.1.2
The type of the parent.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER unknown(0), breaker(1), section(2), custom(3)  

outletParentOID 1.3.6.1.4.1.534.6.6.7.6.2.1.3
Object ID of a parent object.
Status: current Access: read-only
OBJECT-TYPE    
  OBJECT IDENTIFIER  

outletVoltageTable 1.3.6.1.4.1.534.6.6.7.6.3
A list of outlet voltage measurements.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    OutletVoltageEntry

outletVoltageEntry 1.3.6.1.4.1.534.6.6.7.6.3.1
An entry for an outlet voltage measurement.
Status: current Access: not-accessible
OBJECT-TYPE    
  OutletVoltageEntry  

outletVoltage 1.3.6.1.4.1.534.6.6.7.6.3.1.2
Units are millivolts.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

outletVoltageThStatus 1.3.6.1.4.1.534.6.6.7.6.3.1.3
Status of the measured outlet voltage relative to the configured thresholds.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER good(0), lowWarning(1), lowCritical(2), highWarning(3), highCritical(4)  

outletVoltageThLowerWarning 1.3.6.1.4.1.534.6.6.7.6.3.1.4
Lower warning threshold. Units are millivolts. A negative value indicates that this object is not available.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 -1..500000  

outletVoltageThLowerCritical 1.3.6.1.4.1.534.6.6.7.6.3.1.5
Lower critical threshold. Units are millivolts. A negative value indicates that this object is not available.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 -1..500000  

outletVoltageThUpperWarning 1.3.6.1.4.1.534.6.6.7.6.3.1.6
Upper warning threshold. Units are millivolts. A negative value indicates that this object is not available.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 -1..500000  

outletVoltageThUpperCritical 1.3.6.1.4.1.534.6.6.7.6.3.1.7
Upper critical threshold. Units are millivolts. A negative value indicates that this object is not available.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 -1..500000  

outletCurrentTable 1.3.6.1.4.1.534.6.6.7.6.4
A list of outlet current measurements.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    OutletCurrentEntry

outletCurrentEntry 1.3.6.1.4.1.534.6.6.7.6.4.1
An entry for an outlet current measurement.
Status: current Access: not-accessible
OBJECT-TYPE    
  OutletCurrentEntry  

outletCurrentCapacity 1.3.6.1.4.1.534.6.6.7.6.4.1.2
Rated current capacity of the outlet. Units are milliamps. A negative value indicates that the hardware current capacity is unknown.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

outletCurrent 1.3.6.1.4.1.534.6.6.7.6.4.1.3
An outlet current measurement value. Units are milliamps.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

outletCurrentThStatus 1.3.6.1.4.1.534.6.6.7.6.4.1.4
Status of the measured outlet current relative to the configured thresholds.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER good(0), lowWarning(1), lowCritical(2), highWarning(3), highCritical(4)  

outletCurrentThLowerWarning 1.3.6.1.4.1.534.6.6.7.6.4.1.5
Lower warning threshold. Units are milliamps. A negative value indicates that this object is not available.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 -1..100000  

outletCurrentThLowerCritical 1.3.6.1.4.1.534.6.6.7.6.4.1.6
Lower critical threshold. Units are milliamps. A negative value indicates that this object is not available.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 -1..100000  

outletCurrentThUpperWarning 1.3.6.1.4.1.534.6.6.7.6.4.1.7
Upper warning threshold. Units are milliamps. A negative value indicates that this object is not available.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 -1..100000  

outletCurrentThUpperCritical 1.3.6.1.4.1.534.6.6.7.6.4.1.8
Upper critical threshold. Units are milliamps. A negative value indicates that this object is not available.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 -1..100000  

outletCurrentCrestFactor 1.3.6.1.4.1.534.6.6.7.6.4.1.9
Current crest factor. Units are in milli, for example a crest factor of 1.414 will be returned as 1414. A negative value indicates that this object is not available.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

outletCurrentPercentLoad 1.3.6.1.4.1.534.6.6.7.6.4.1.10
Current percent load, based on the rated current capacity. Units are percentage, for example 80% will be returned as 80. A negative value indicates that this object is not available.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

outletPowerTable 1.3.6.1.4.1.534.6.6.7.6.5
A list of outlet power measurements.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    OutletPowerEntry

outletPowerEntry 1.3.6.1.4.1.534.6.6.7.6.5.1
An entry for an outlet power measurement.
Status: current Access: not-accessible
OBJECT-TYPE    
  OutletPowerEntry  

outletVA 1.3.6.1.4.1.534.6.6.7.6.5.1.2
An outlet VA value. Units are VA. A negative value indicates that this object is not available.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

outletWatts 1.3.6.1.4.1.534.6.6.7.6.5.1.3
An outlet Watts value. Units are Watts. A negative value indicates that this object is not available.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

outletWh 1.3.6.1.4.1.534.6.6.7.6.5.1.4
Units are Watt-hours. This object is writable so that it can be reset to 0. When it is written to, the inputWhTotalTimer will be reset to 0 as well.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 0..4294967295  

outletWhTimer 1.3.6.1.4.1.534.6.6.7.6.5.1.5
Timestamp of when outlet Watt-hours (outletWh) was last reset.
Status: current Access: read-only
OBJECT-TYPE    
  UnixTimeStamp  

outletPowerFactor 1.3.6.1.4.1.534.6.6.7.6.5.1.6
An outlet PF value. Units are in thousandths, for example a power factor of 0.958 would be returned as 958, and 0.92 would be returned as 920. A negative value indicates that this object is not available.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

outletVAR 1.3.6.1.4.1.534.6.6.7.6.5.1.7
An outlet VAR value. Units are VAR. A negative value indicates that this object is not available.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

outletControlTable 1.3.6.1.4.1.534.6.6.7.6.6
A list of controllable outlets.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    OutletControlEntry

outletControlEntry 1.3.6.1.4.1.534.6.6.7.6.6.1
An entry for a controllable outlet.
Status: current Access: not-accessible
OBJECT-TYPE    
  OutletControlEntry  

outletControlStatus 1.3.6.1.4.1.534.6.6.7.6.6.1.2
Current state of a controlled outlet.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER off(0), on(1), pendingOff(2), pendingOn(3)  

outletControlOffCmd 1.3.6.1.4.1.534.6.6.7.6.6.1.3
Outlet control command. Once the command is issued, the outlet will turn Off immediately. 0-n : Time in seconds until the outlet command is issued -1 : Cancel a pending outlet Off command When read, returns -1 if no command is pending, or the current downcount in seconds of a pending command. Certain ePDUs (mainly those with part numbers beginning with IPV or IPC) do not support delayed control commands. These will respond with an error if a command value of > 0 is written to this object.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 -1..99999  

outletControlOnCmd 1.3.6.1.4.1.534.6.6.7.6.6.1.4
Outlet control command. Once the command is issued, the outlet will turn On immediately. 0-n : Time in seconds until the outlet command is issued -1 : Cancel a pending outlet On command When read, returns -1 if no command is pending, or the current downcount in seconds of a pending command. Certain ePDUs (mainly those with part numbers beginning with IPV or IPC) do not support delayed control commands. These will respond with an error if a command value of > 0 is written to this object.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 -1..99999  

outletControlRebootCmd 1.3.6.1.4.1.534.6.6.7.6.6.1.5
Outlet control command. For outlets that are On prior to this Reboot command, they will switch Off immediately when the command is issued, remain Off for outletControlRebootOffTime seconds, and then turn back On. For outlets that are Off prior to the Reboot command, they will turn On after a delay of outletControlRebootOffTime seconds from when the command is issued. 0-n : Time in seconds until the Reboot command is issued -1 : Cancel a pending outlet Reboot command When read, returns -1 if no command is pending, or the current downcount in seconds of a pending command. Certain ePDUs (mainly those with part numbers beginning with IPV or IPC) do not support delayed control commands. These will respond with an error if a command value of > 0 is written to this object.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 -1..99999  

outletControlPowerOnState 1.3.6.1.4.1.534.6.6.7.6.6.1.6
Determines the outlet state when power is applied to the unit. 0 : not restart at device startup 1 : should sequence back ON in line with outletControlSequenceTime 2 : should take the state the outlet had when power was lost. If the state was ON, should sequence back ON in line with outletControlSequenceTime.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER off(0), on(1), lastState(2)  

outletControlSequenceDelay 1.3.6.1.4.1.534.6.6.7.6.6.1.7
Time delay in seconds from when a Global Sequence On command is issued to when the command is executed on this outlet. This delay is also used as a power-on delay. Set to -1 to exclude this outlet from Global Sequence On commands.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 -1..99999  

outletControlRebootOffTime 1.3.6.1.4.1.534.6.6.7.6.6.1.8
Time delay in seconds that the outlet should remain in the Off state when executing a Reboot command.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 1..99999  

outletControlSwitchable 1.3.6.1.4.1.534.6.6.7.6.6.1.9
Determines the outlet capability to be controlled On/Off from the communication channels. 1 : control On/Off enabled 2 : control On/Off disabled.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER switchable(1), notSwitchable(2)  

outletControlShutoffDelay 1.3.6.1.4.1.534.6.6.7.6.6.1.10
Time delay in seconds that could be taken in account before shutting of the outlet. An application which need to shutoff properly an outlet will read this parameter first then write it to the command outletControlOffCmd.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 -1..99999  

temperatureTable 1.3.6.1.4.1.534.6.6.7.7.1
A list of temperature probe measurements. The number of entries is given by temperatureCount.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    TemperatureEntry

temperatureEntry 1.3.6.1.4.1.534.6.6.7.7.1.1
An entry for a temperature measurement.
Status: current Access: not-accessible
OBJECT-TYPE    
  TemperatureEntry  

temperatureIndex 1.3.6.1.4.1.534.6.6.7.7.1.1.1
A unique value for each temperature probe measurement. Its value ranges from 1 to temperatureCount.
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32 1..2  

temperatureName 1.3.6.1.4.1.534.6.6.7.7.1.1.2
A descriptive name for the temperature probe.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(1..31)  

temperatureProbeStatus 1.3.6.1.4.1.534.6.6.7.7.1.1.3
Indicates whether a probe is connected or not.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER bad(-1), disconnected(0), connected(1)  

temperatureValue 1.3.6.1.4.1.534.6.6.7.7.1.1.4
Units are in tenths of a degree according to the scale specified by temperatureScale (either Fahrenheit or Celsius). Divide by ten to get degrees.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

temperatureThStatus 1.3.6.1.4.1.534.6.6.7.7.1.1.5
Status of the measured temperature relative to the configured thresholds.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER good(0), lowWarning(1), lowCritical(2), highWarning(3), highCritical(4)  

temperatureThLowerWarning 1.3.6.1.4.1.534.6.6.7.7.1.1.6
Lower warning threshold. Units are tenths of a degree. A negative value indicates that this object is not available.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 -1..150000  

temperatureThLowerCritical 1.3.6.1.4.1.534.6.6.7.7.1.1.7
Lower critical threshold. Units are tenths of a degree. A negative value indicates that this object is not available.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 -1..150000  

temperatureThUpperWarning 1.3.6.1.4.1.534.6.6.7.7.1.1.8
Upper warning threshold. Units are tenths of a degree. A negative value indicates that this object is not available.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 -1..150000  

temperatureThUpperCritical 1.3.6.1.4.1.534.6.6.7.7.1.1.9
Upper critical threshold. Units are tenths of a degree. A negative value indicates that this object is not available.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 -1..150000  

humidityTable 1.3.6.1.4.1.534.6.6.7.7.2
A list of humidity probe measurements. The number of entries is given by humidityCount.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    HumidityEntry

humidityEntry 1.3.6.1.4.1.534.6.6.7.7.2.1
An entry for a humidity measurement.
Status: current Access: not-accessible
OBJECT-TYPE    
  HumidityEntry  

humidityIndex 1.3.6.1.4.1.534.6.6.7.7.2.1.1
A unique value for each humidity probe measurement. Its value ranges from 1 to humidityCount.
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32 1..2  

humidityName 1.3.6.1.4.1.534.6.6.7.7.2.1.2
A descriptive name for the humidity probe.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(1..31)  

humidityProbeStatus 1.3.6.1.4.1.534.6.6.7.7.2.1.3
Indicates whether a probe is connected or not.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER bad(-1), disconnected(0), connected(1)  

humidityValue 1.3.6.1.4.1.534.6.6.7.7.2.1.4
Units are tenths of a percent relative humidity. Divide the value by 10 to get %RH.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

humidityThStatus 1.3.6.1.4.1.534.6.6.7.7.2.1.5
Status of the measured humidity relative to the configured thresholds.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER good(0), lowWarning(1), lowCritical(2), highWarning(3), highCritical(4)  

humidityThLowerWarning 1.3.6.1.4.1.534.6.6.7.7.2.1.6
Lower warning threshold. Units are 0.1 %RH. A negative value indicates that this object is not available.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 -1..1000  

humidityThLowerCritical 1.3.6.1.4.1.534.6.6.7.7.2.1.7
Lower critical threshold. Units are 0.1 %RH. A negative value indicates that this object is not available.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 -1..1000  

humidityThUpperWarning 1.3.6.1.4.1.534.6.6.7.7.2.1.8
Upper warning threshold. Units are 0.1 %RH. A negative value indicates that this object is not available.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 -1..1000  

humidityThUpperCritical 1.3.6.1.4.1.534.6.6.7.7.2.1.9
Upper critical threshold. Units are 0.1 %RH. A negative value indicates that this object is not available.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 -1..1000  

contactTable 1.3.6.1.4.1.534.6.6.7.7.3
A list of contact sensors. The number of entries is given by contactCount.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ContactEntry

contactEntry 1.3.6.1.4.1.534.6.6.7.7.3.1
An entry for a contact sensor
Status: current Access: not-accessible
OBJECT-TYPE    
  ContactEntry  

contactIndex 1.3.6.1.4.1.534.6.6.7.7.3.1.1
A unique value for each contact sensor. Its value ranges from 1 to contactCount.
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32 1..3  

contactName 1.3.6.1.4.1.534.6.6.7.7.3.1.2
A descriptive name for the contact sensor.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(1..31)  

contactProbeStatus 1.3.6.1.4.1.534.6.6.7.7.3.1.3
Indicates whether a probe is connected or not. Will not be returned if the contact sensor is internal to the ePDU, in that case only contactState should be read.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER bad(-1), disconnected(0), connected(1)  

contactState 1.3.6.1.4.1.534.6.6.7.7.3.1.4
The state of the contact sensor.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER contactBad(-1), contactOpen(0), contactClosed(1)  

eatonEpduCompliances 1.3.6.1.4.1.534.6.6.7.25.1
The requirements for conforming to the ePDU MIB.
Status: current Access: read-only
MODULE-COMPLIANCE    

epduRequiredGroup 1.3.6.1.4.1.534.6.6.7.25.5.1
Minimal objects are required to conform to this MIB.
Status: current Access: read-only
OBJECT-GROUP    

epduOptionalGroup 1.3.6.1.4.1.534.6.6.7.25.5.2
Most objects in this MIB are optional.
Status: current Access: read-only
OBJECT-GROUP    

epduNotifyGroup 1.3.6.1.4.1.534.6.6.7.25.5.3
These notifications will be supported depending on the features of the ePDU. Check the web interface for options to turn these notifications on/off. If an option is not listed, then the ePDU likely does not support that notification.
Status: current Access: read-only
NOTIFICATION-GROUP