DVB-MGSIGNALCHARACTERISTICS-MIB

File: DVB-MGSIGNALCHARACTERISTICS-MIB.mib (44618 bytes)

Imported modules

DVB-MGTR101290-MIB SNMPv2-CONF SNMPv2-SMI
SNMPv2-TC

Imported symbols

PIDPlusOne FloatingPoint ServiceId
InputNumber RateStatus DeliverySystemType
Modulation OBJECT-GROUP MODULE-COMPLIANCE
NOTIFICATION-GROUP enterprises Unsigned32
OBJECT-TYPE MODULE-IDENTITY NOTIFICATION-TYPE
DateAndTime TruthValue TEXTUAL-CONVENTION

Defined Types

CASystemID  
Representation of CA_system_ID as found in a CA_descriptor. A value of -1 means that the CA_system_ID is unknown.
TEXTUAL-CONVENTION    
  INTEGER -1..65535  

EncryptionState  
Used to indicate whether a service or PID is encrypted or unencrypted. The value unknown means that the information is not available, for example because the instrument does not gather this information.
TEXTUAL-CONVENTION    
  INTEGER unencrypted(1), encrypted(2), unknown(3)  

GuardInterval  
Guard interval used in the DVB-T modulation scheme.
TEXTUAL-CONVENTION    
  INTEGER guard1over32(1), guard1over16(2), guard1over8(3), guard1over4(4)  

InnerCodeRate  
This is used to specify the inner (Viterbi) code rate of a transmission.
TEXTUAL-CONVENTION    
  INTEGER rateNone(1), rate1over2(2), rate2over3(3), rate3over4(4), rate5over6(5), rate7over8(6)  

NetworkID  
This represents a network_id or original_network_id as used in the SI tables. A value of -1 indicates that value is unknown.
TEXTUAL-CONVENTION    
  INTEGER -1..65535  

PID  
An object of type PID directly represents an MPEG-2 PID number
TEXTUAL-CONVENTION    
  INTEGER 0..8191  

ReadableString  
An octet string containing a human-readable string. This string may have originally been encoded as specified in EN 300 468 Annex A, but this is not a requirement. To maintain generality, the information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in RFC2279. Control codes are interpreted as specified in EN 300 468 Annex A, section A.1. The interpretation of other control codes is undefined. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character/code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding.
TEXTUAL-CONVENTION    
  OCTET STRING Size(0..255)  

TerrestrialTransmissionMode  
Used to inform whether a DVB-T transmission uses 2k or 8k mode.
TEXTUAL-CONVENTION    
  INTEGER carriers2k(1), carriers8k(2)  

StructureTrapControlEntry  
SEQUENCE    
  structureTrapControlInputNumber InputNumber
  structureTrapControlOID OBJECT IDENTIFIER
  structureTrapControlChangeTime DateAndTime
  structureTrapControlRateStatus RateStatus
  structureTrapControlPeriod Unsigned32

MgTSEntry  
SEQUENCE    
  mgTSInputNumber InputNumber
  mgTSId INTEGER
  mgTSOriginalNetworkID NetworkID
  mgTSNetworkID NetworkID
  mgTSNetworkName ReadableString

MgServiceEntry  
SEQUENCE    
  mgServiceInputNumber InputNumber
  mgServiceNumber ServiceId
  mgServiceType INTEGER
  mgServiceName ReadableString
  mgServiceProviderName ReadableString
  mgServicePMTPID PID
  mgServicePCRPID PID
  mgServiceCondAccess EncryptionState
  mgServiceEITComponentDescriptor ReadableString

MgPIDEntry  
SEQUENCE    
  mgPIDInputNumber InputNumber
  mgPIDServiceNumber ServiceId
  mgPIDNumber PIDPlusOne
  mgPIDType INTEGER
  mgPIDCondAccess EncryptionState

MgEMMEntry  
SEQUENCE    
  mgEMMInputNumber InputNumber
  mgEMMCaPID PIDPlusOne
  mgEMMCASystemID CASystemID

MgServiceECMEntry  
SEQUENCE    
  mgServiceECMInputNumber InputNumber
  mgServiceECMServiceNumber ServiceId
  mgServiceECMCaPID PIDPlusOne
  mgServiceECMCASystemID CASystemID

MgPIDECMEntry  
SEQUENCE    
  mgPIDECMInputNumber InputNumber
  mgPIDECMServiceNumber ServiceId
  mgPIDECMPID PIDPlusOne
  mgPIDECMCaPID PIDPlusOne
  mgPIDECMCASystemID CASystemID

MgNITDeliverySystemEntry  
SEQUENCE    
  mgNITDSInputNumber InputNumber
  mgNITDSSystemType DeliverySystemType
  mgNITDSFrequency FloatingPoint
  mgNITDSFecOuter INTEGER
  mgNITDSCableModulation INTEGER
  mgNITDSSymbolRate Unsigned32
  mgNITDSFecInner INTEGER
  mgNITDSOrbitalPosition FloatingPoint
  mgNITDSWestEastFlag INTEGER
  mgNITDSPolarization INTEGER
  mgNITDSSatelliteModulation INTEGER
  mgNITDSBandwidth INTEGER
  mgNITDSConstellation INTEGER
  mgNITDSHierarchyInformation INTEGER
  mgNITDSCodeRateHPStream INTEGER
  mgNITDSCodeRateLPStream INTEGER
  mgNITDSGuardInterval INTEGER
  mgNITDSTransmissionMode INTEGER
  mgNITDSOtherFrequencyFlag INTEGER

RfCharacteristicsTrapControlEntry  
SEQUENCE    
  rfCharacteristicsTrapControlInputNumber InputNumber
  rfCharacteristicsTrapControlOID OBJECT IDENTIFIER
  rfCharacteristicsTrapControlChangeTime DateAndTime
  rfCharacteristicsTrapControlRateStatus RateStatus
  rfCharacteristicsTrapControlPeriod Unsigned32

MgRFCharacteristicsEntry  
SEQUENCE    
  mgRFInputNumber InputNumber
  mgRFSystemType DeliverySystemType
  mgRFCentreFrequency FloatingPoint
  mgRFModulation Modulation
  mgRFFecInner InnerCodeRate
  mgRFFecInnerLP InnerCodeRate
  mgRFSymbolRate FloatingPoint
  mgRFBandwidth FloatingPoint
  mgRFTransmissionMode TerrestrialTransmissionMode
  mgRFIsHierarchical TruthValue
  mgRFGuardInterval GuardInterval

Defined Values

mgSignalCharacteristics 1.3.6.1.4.1.2696.3.3
DVB Measurement Group Signal Characteristics MIB module. This mgSignalCharacteristics module contains Transport Stream structure information and RF characteristics information to assist in interpreting measurements and tests, in particular those specified in TR 101 290.
MODULE-IDENTITY    

dvb 1.3.6.1.4.1.2696
OBJECT IDENTIFIER    

mg 1.3.6.1.4.1.2696.3
OBJECT IDENTIFIER    

mgSignalCharacteristicsObjects 1.3.6.1.4.1.2696.3.3.1
OBJECT IDENTIFIER    

mgTSStructure 1.3.6.1.4.1.2696.3.3.1.1
OBJECT IDENTIFIER    

mgTSStructureTrap 1.3.6.1.4.1.2696.3.3.1.1.1
OBJECT IDENTIFIER    

structureTrapPrefix 1.3.6.1.4.1.2696.3.3.1.1.1.0
OBJECT IDENTIFIER    

tsStructureChangeTrap 1.3.6.1.4.1.2696.3.3.1.1.1.0.1
Trap which is sent when any value within the mgTSStructure branch of this MIB changes. Transmission of the trap is subject to rate control through the structureTrapControlRateStatus object.
Status: current Access: read-only
NOTIFICATION-TYPE    

structureTrapControlTable 1.3.6.1.4.1.2696.3.3.1.1.1.1
Per-input table of values which control the generation of tsStructureChangeTrap traps.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    StructureTrapControlEntry

structureTrapControlEntry 1.3.6.1.4.1.2696.3.3.1.1.1.1.1
Row specification
Status: current Access: not-accessible
OBJECT-TYPE    
  StructureTrapControlEntry  

structureTrapControlInputNumber 1.3.6.1.4.1.2696.3.3.1.1.1.1.1.1
Transport Stream input to which the trap control objects apply.
Status: current Access: not-accessible
OBJECT-TYPE    
  InputNumber  

structureTrapControlOID 1.3.6.1.4.1.2696.3.3.1.1.1.1.1.2
This object holds the OID of the object within the mgTSStructure branch of the MIB whose change triggered the trap. It is present for the formal purpose of defining the variable bindings returned with the tsStructureChangeTrap. It is not accessible for normal reading.
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  OBJECT IDENTIFIER  

structureTrapControlChangeTime 1.3.6.1.4.1.2696.3.3.1.1.1.1.1.3
This indicates the time when the change which triggered the trap occurred. It is present for the formal purpose of defining the variable bindings returned with the tsStructureChangeTrap. It is not accessible for normal reading.
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DateAndTime  

structureTrapControlRateStatus 1.3.6.1.4.1.2696.3.3.1.1.1.1.1.4
This object is used for rate control of traps, preventing overload of the management network by transmission of an excessive number of traps. The value 'disabled' means that traps are never sent. The value 'enabled' means that a trap will be sent when triggered. When a trap is sent, the agent changes the value of this object to 'enabledThrottled'. In this state the agent will not send any more traps. The agent automatically changes the value back to 'enabled' when the time specified by trapControlPeriod expires. A management application may set the value to 'enabled' at any time, but must never set the value to 'enabledThrottled'.
Status: current Access: read-write
OBJECT-TYPE    
  RateStatus  

structureTrapControlPeriod 1.3.6.1.4.1.2696.3.3.1.1.1.1.1.5
The agent will ensure that the interval between sending traps is no shorter than this time period (unless overridden by the manager).
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 0..3600000  

structureTrapInput 1.3.6.1.4.1.2696.3.3.1.1.1.2
The Transport Stream input whose change triggered the current trap. This information can also be obtained by analysing the structureTrapControlOID, but structureTrapInput provides the information directly. This object is present for the formal purpose of defining the variable bindings returned with the tsStructureChangeTrap. It is not accessible for normal reading.
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  InputNumber  

mgTSTable 1.3.6.1.4.1.2696.3.3.1.1.2
PSI/SI information relating to the whole Transport Stream
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MgTSEntry

mgTSEntry 1.3.6.1.4.1.2696.3.3.1.1.2.1
Row specification
Status: current Access: not-accessible
OBJECT-TYPE    
  MgTSEntry  

mgTSInputNumber 1.3.6.1.4.1.2696.3.3.1.1.2.1.1
The physical input on which this Transport Stream appears
Status: current Access: not-accessible
OBJECT-TYPE    
  InputNumber  

mgTSId 1.3.6.1.4.1.2696.3.3.1.1.2.1.2
The transport_stream_id for this Transport Stream as read from the PAT. If the transport_stream_id is unknown, this object has the value -1.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER -1..65535  

mgTSOriginalNetworkID 1.3.6.1.4.1.2696.3.3.1.1.2.1.3
The original_network_id for this Transport Stream. This is found by reading the transport_stream_id from the PAT. This transport_stream_id is then located in the transport_stream_loop of the NIT (actual transport stream). The value of mgTSOriginalNetworkID is the original_network_id found in this instance of the loop.
Status: current Access: read-only
OBJECT-TYPE    
  NetworkID  

mgTSNetworkID 1.3.6.1.4.1.2696.3.3.1.1.2.1.4
The network_id for this Transport Stream as read from the NIT. This is found by reading the network_id in the NIT (actual_network)
Status: current Access: read-only
OBJECT-TYPE    
  NetworkID  

mgTSNetworkName 1.3.6.1.4.1.2696.3.3.1.1.2.1.5
network_name for this Transport Stream as read from the NIT. This is found by reading the network name descriptor in the NIT (actual_network). If the network_name is unknown, the value of this object is a zero length string.
Status: current Access: read-only
OBJECT-TYPE    
  ReadableString  

mgServiceTable 1.3.6.1.4.1.2696.3.3.1.1.3
PSI/SI information relating to each service within the Transport Stream. A service is included in the table if it is found in both the PAT and the PMT.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MgServiceEntry

mgServiceEntry 1.3.6.1.4.1.2696.3.3.1.1.3.1
Row specification
Status: current Access: not-accessible
OBJECT-TYPE    
  MgServiceEntry  

mgServiceInputNumber 1.3.6.1.4.1.2696.3.3.1.1.3.1.1
The physical input on which this Transport Stream appears
Status: current Access: not-accessible
OBJECT-TYPE    
  InputNumber  

mgServiceNumber 1.3.6.1.4.1.2696.3.3.1.1.3.1.2
The program_number/service_id to which the information in the rest of the row applies.
Status: current Access: not-accessible
OBJECT-TYPE    
  ServiceId  

mgServiceType 1.3.6.1.4.1.2696.3.3.1.1.3.1.3
The service_type from the service_descriptor field in the SDT. A value of -1 indicates that the service_type is unknown.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER -1..255  

mgServiceName 1.3.6.1.4.1.2696.3.3.1.1.3.1.4
The service_name from the service_descriptor in the SDT. If this information is not available, the value of this object will be a zero length string.
Status: current Access: read-only
OBJECT-TYPE    
  ReadableString  

mgServiceProviderName 1.3.6.1.4.1.2696.3.3.1.1.3.1.5
The service_provider_name from the service_descriptor in the SDT. If this information is not available, the value of this object will be a zero length string.
Status: current Access: read-only
OBJECT-TYPE    
  ReadableString  

mgServicePMTPID 1.3.6.1.4.1.2696.3.3.1.1.3.1.6
The PMT PID for this service as read from the PAT
Status: current Access: read-only
OBJECT-TYPE    
  PID  

mgServicePCRPID 1.3.6.1.4.1.2696.3.3.1.1.3.1.7
The PCR PID for this service as read from the PMT
Status: current Access: read-only
OBJECT-TYPE    
  PID  

mgServiceCondAccess 1.3.6.1.4.1.2696.3.3.1.1.3.1.8
The encryption state of the service, derived from the free_CA_mode bit in the SDT
Status: current Access: read-only
OBJECT-TYPE    
  EncryptionState  

mgServiceEITComponentDescriptor 1.3.6.1.4.1.2696.3.3.1.1.3.1.9
This is a text description of the main elementary stream in the service as read from the component_descriptor in the EIT. If this information is not available, the value of this object will be a zero length string.
Status: current Access: read-only
OBJECT-TYPE    
  ReadableString  

mgPIDTable 1.3.6.1.4.1.2696.3.3.1.1.4
PSI/SI information relating to each PID in each service in the Transport Stream. A PID is included in the table if it listed as an elementary_PID in the PMT for the service.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MgPIDEntry

mgPIDEntry 1.3.6.1.4.1.2696.3.3.1.1.4.1
Row specification
Status: current Access: not-accessible
OBJECT-TYPE    
  MgPIDEntry  

mgPIDInputNumber 1.3.6.1.4.1.2696.3.3.1.1.4.1.1
The physical input on which this Transport Stream appears
Status: current Access: not-accessible
OBJECT-TYPE    
  InputNumber  

mgPIDServiceNumber 1.3.6.1.4.1.2696.3.3.1.1.4.1.2
The program_number/service_id to which the row information applies.
Status: current Access: not-accessible
OBJECT-TYPE    
  ServiceId  

mgPIDNumber 1.3.6.1.4.1.2696.3.3.1.1.4.1.3
The PID, included in the service identified by mgPIDServiceNumber, to which the information in the row applies.
Status: current Access: not-accessible
OBJECT-TYPE    
  PIDPlusOne  

mgPIDType 1.3.6.1.4.1.2696.3.3.1.1.4.1.4
The stream_type read from the PMT
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..255  

mgPIDCondAccess 1.3.6.1.4.1.2696.3.3.1.1.4.1.5
The encryption state of the PID. This is deduced from the values of the transport_scrambling_control field in the Transport Stream packet headers for this PID.
Status: current Access: read-only
OBJECT-TYPE    
  EncryptionState  

mgEMMTable 1.3.6.1.4.1.2696.3.3.1.1.5
This table identifies the PIDs occupied by EMMs
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MgEMMEntry

mgEMMEntry 1.3.6.1.4.1.2696.3.3.1.1.5.1
Row specification
Status: current Access: not-accessible
OBJECT-TYPE    
  MgEMMEntry  

mgEMMInputNumber 1.3.6.1.4.1.2696.3.3.1.1.5.1.1
The physical input on which this Transport Stream appears
Status: current Access: not-accessible
OBJECT-TYPE    
  InputNumber  

mgEMMCaPID 1.3.6.1.4.1.2696.3.3.1.1.5.1.2
The CA_PID from the CA_descriptor in the CAT plus one. This indicates the PID on which the EMM is found.
Status: current Access: not-accessible
OBJECT-TYPE    
  PIDPlusOne  

mgEMMCASystemID 1.3.6.1.4.1.2696.3.3.1.1.5.1.3
The CA_system_ID from the CA_descriptor in the CAT
Status: current Access: read-only
OBJECT-TYPE    
  CASystemID  

mgServiceECMTable 1.3.6.1.4.1.2696.3.3.1.1.6
This table identifies the PIDs occupied by ECMs relating to a whole service. This information is found in the first descriptor loop of a TS_program_map_section.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MgServiceECMEntry

mgServiceECMEntry 1.3.6.1.4.1.2696.3.3.1.1.6.1
Row specification
Status: current Access: not-accessible
OBJECT-TYPE    
  MgServiceECMEntry  

mgServiceECMInputNumber 1.3.6.1.4.1.2696.3.3.1.1.6.1.1
The physical input on which this Transport Stream appears
Status: current Access: not-accessible
OBJECT-TYPE    
  InputNumber  

mgServiceECMServiceNumber 1.3.6.1.4.1.2696.3.3.1.1.6.1.2
The program_number/service_id to which the information in the row applies.
Status: current Access: not-accessible
OBJECT-TYPE    
  ServiceId  

mgServiceECMCaPID 1.3.6.1.4.1.2696.3.3.1.1.6.1.3
The CA_PID from the CA_descriptor in the PMT plus one. This indicates the PID on which the ECM is found.
Status: current Access: not-accessible
OBJECT-TYPE    
  PIDPlusOne  

mgServiceECMCASystemID 1.3.6.1.4.1.2696.3.3.1.1.6.1.4
The CA_system_ID from the CA_descriptor in the PMT
Status: current Access: read-only
OBJECT-TYPE    
  CASystemID  

mgPIDECMTable 1.3.6.1.4.1.2696.3.3.1.1.7
This table identifies the PIDs occupied by ECMs related to a single elementary stream. This information is found in the elementary stream specific descriptor loop of a TS_program_map_section.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MgPIDECMEntry

mgPIDECMEntry 1.3.6.1.4.1.2696.3.3.1.1.7.1
Row specification
Status: current Access: not-accessible
OBJECT-TYPE    
  MgPIDECMEntry  

mgPIDECMInputNumber 1.3.6.1.4.1.2696.3.3.1.1.7.1.1
The physical input on which this Transport Stream appears
Status: current Access: not-accessible
OBJECT-TYPE    
  InputNumber  

mgPIDECMServiceNumber 1.3.6.1.4.1.2696.3.3.1.1.7.1.2
The program_number/service_id to which the information in the row applies.
Status: current Access: not-accessible
OBJECT-TYPE    
  ServiceId  

mgPIDECMPID 1.3.6.1.4.1.2696.3.3.1.1.7.1.3
The elementary stream PID which is unscrambled by this ECM.
Status: current Access: not-accessible
OBJECT-TYPE    
  PIDPlusOne  

mgPIDECMCaPID 1.3.6.1.4.1.2696.3.3.1.1.7.1.4
The CA_PID from the CA_descriptor in the PMT plus one. This indicates the PID on which the ECM is found.
Status: current Access: not-accessible
OBJECT-TYPE    
  PIDPlusOne  

mgPIDECMCASystemID 1.3.6.1.4.1.2696.3.3.1.1.7.1.5
The CA_system_ID from the CA_descriptor in the PMT
Status: current Access: read-only
OBJECT-TYPE    
  CASystemID  

mgNITDeliverySystemTable 1.3.6.1.4.1.2696.3.3.1.1.8
Delivery system information for this Transport Stream read from the delivery system descriptors in the NIT. This information is found by reading the transport_stream_id from the PAT. This transport_stream_id is then located in the transport_stream_loop of the NIT (actual_network). The delivery system descriptor found in this instance of the loop is analysed to obtain the values in this table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MgNITDeliverySystemEntry

mgNITDeliverySystemEntry 1.3.6.1.4.1.2696.3.3.1.1.8.1
Row specification
Status: current Access: not-accessible
OBJECT-TYPE    
  MgNITDeliverySystemEntry  

mgNITDSInputNumber 1.3.6.1.4.1.2696.3.3.1.1.8.1.1
The physical input on which this Transport Stream appears
Status: current Access: not-accessible
OBJECT-TYPE    
  InputNumber  

mgNITDSSystemType 1.3.6.1.4.1.2696.3.3.1.1.8.1.2
Which delivery system is in use. The value of this object determines which other objects in this table row have valid values. If this object has the value 'unknown' none of the other objects in this table row have valid values.
Status: current Access: read-only
OBJECT-TYPE    
  DeliverySystemType  

mgNITDSFrequency 1.3.6.1.4.1.2696.3.3.1.1.8.1.3
The frequency or centre_frequency for the transmission expressed in MHz Valid for: cable, satellite, terrestrial
Status: current Access: read-only
OBJECT-TYPE    
  FloatingPoint  

mgNITDSFecOuter 1.3.6.1.4.1.2696.3.3.1.1.8.1.4
The Outer Forward Error Correction Code, values as specified for the cable_delivery_system_descriptor. Valid for: cable
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..15  

mgNITDSCableModulation 1.3.6.1.4.1.2696.3.3.1.1.8.1.5
Modulation scheme, values as specified for the cable_delivery_system_descriptor Valid for: cable
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..255  

mgNITDSSymbolRate 1.3.6.1.4.1.2696.3.3.1.1.8.1.6
The symbol rate in symbols per second Valid for: cable, satellite
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

mgNITDSFecInner 1.3.6.1.4.1.2696.3.3.1.1.8.1.7
The inner FEC scheme, values as specified for the cable_delivery_system_descriptor Valid for: cable, satellite
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..15  

mgNITDSOrbitalPosition 1.3.6.1.4.1.2696.3.3.1.1.8.1.8
The orbital position in degrees Valid for: satellite
Status: current Access: read-only
OBJECT-TYPE    
  FloatingPoint  

mgNITDSWestEastFlag 1.3.6.1.4.1.2696.3.3.1.1.8.1.9
Orbital position direction: east (1) or west (0). Valid for: satellite
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER west(0), east(1)  

mgNITDSPolarization 1.3.6.1.4.1.2696.3.3.1.1.8.1.10
Polarization, values as specified for the satellite_delivery_system_descriptor Valid for: satellite
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..3  

mgNITDSSatelliteModulation 1.3.6.1.4.1.2696.3.3.1.1.8.1.11
Modulation scheme, values as specified for the satellite_delivery_system_descriptor Valid for: satellite
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..31  

mgNITDSBandwidth 1.3.6.1.4.1.2696.3.3.1.1.8.1.12
The bandwidth, values as specified for the terrestrial_delivery_system_descriptor Valid for: terrestrial
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..7  

mgNITDSConstellation 1.3.6.1.4.1.2696.3.3.1.1.8.1.13
The modulation constellation: values as specified for the terrestrial_delivery_system_descriptor Valid for: terrestrial
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..3  

mgNITDSHierarchyInformation 1.3.6.1.4.1.2696.3.3.1.1.8.1.14
Hierarchy Information: values as specified for the terrestrial_delivery_system_descriptor Valid for: terrestrial
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..7  

mgNITDSCodeRateHPStream 1.3.6.1.4.1.2696.3.3.1.1.8.1.15
The code rate for the high priority stream: values as specified for the terrestrial_delivery_system_descriptor Valid for: terrestrial
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..7  

mgNITDSCodeRateLPStream 1.3.6.1.4.1.2696.3.3.1.1.8.1.16
The code rate for low priority stream: values as specified for the terrestrial_delivery_system_descriptor Valid for: terrestrial
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..7  

mgNITDSGuardInterval 1.3.6.1.4.1.2696.3.3.1.1.8.1.17
The guard_interval: values as specified for the terrestrial_delivery_system_descriptor Valid for: terrestrial
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..3  

mgNITDSTransmissionMode 1.3.6.1.4.1.2696.3.3.1.1.8.1.18
The transmission_mode: values as specified for the terrestrial_delivery_system_descriptor Valid for: terrestrial
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..3  

mgNITDSOtherFrequencyFlag 1.3.6.1.4.1.2696.3.3.1.1.8.1.19
other_frequency_flag: values as specified for the terrestrial_delivery_system_descriptor Valid for: terrestrial
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..1  

mgRFCharacteristics 1.3.6.1.4.1.2696.3.3.1.2
OBJECT IDENTIFIER    

mgRFCharacteristicsTrap 1.3.6.1.4.1.2696.3.3.1.2.1
OBJECT IDENTIFIER    

rfTrapPrefix 1.3.6.1.4.1.2696.3.3.1.2.1.0
OBJECT IDENTIFIER    

rfCharacteristicsChangeTrap 1.3.6.1.4.1.2696.3.3.1.2.1.0.1
Trap which is sent when a value in the mgRFCharacteristics part of the MIB changes substantially. Transmission of the trap is subject to rate control through the rfCharacteristicsTrapControlRateStatus object.
Status: current Access: read-only
NOTIFICATION-TYPE    

rfCharacteristicsTrapControlTable 1.3.6.1.4.1.2696.3.3.1.2.1.1
Per-input table of values which control the generation of rfCharacteristicsChangeTrap traps.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    RfCharacteristicsTrapControlEntry

rfCharacteristicsTrapControlEntry 1.3.6.1.4.1.2696.3.3.1.2.1.1.1
Row specification
Status: current Access: not-accessible
OBJECT-TYPE    
  RfCharacteristicsTrapControlEntry  

rfCharacteristicsTrapControlInputNumber 1.3.6.1.4.1.2696.3.3.1.2.1.1.1.1
Transport Stream on which an RF value has changed, triggering the transmission of the trap.
Status: current Access: not-accessible
OBJECT-TYPE    
  InputNumber  

rfCharacteristicsTrapControlOID 1.3.6.1.4.1.2696.3.3.1.2.1.1.1.2
This object holds the OID of the object within the rfCharacteristics branch of the MIB whose change triggered the trap. It is present for the formal purpose of defining the variable bindings returned with the rfCharacteristicsChangeTrap. It is not accessible for normal reading. Note that this may not be the only value which has changed; managers need to poll to obtain all the new values that they need.
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  OBJECT IDENTIFIER  

rfCharacteristicsTrapControlChangeTime 1.3.6.1.4.1.2696.3.3.1.2.1.1.1.3
This indicates the time when the change which triggered the trap occurred. It is present for the formal purpose of defining the variable bindings returned with the rfCharacteristicsChangeTrap. It is not accessible for normal reading.
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DateAndTime  

rfCharacteristicsTrapControlRateStatus 1.3.6.1.4.1.2696.3.3.1.2.1.1.1.4
This object is used for rate control of traps, preventing overload of the management network by transmission of an excessive number of traps. The value 'disabled' means that traps are never sent. The value 'enabled' means that a trap will be sent when triggered. When a trap is sent, the agent changes the value of this object to 'enabledThrottled'. In this state the agent will not send any more traps. The agent automatically changes the value back to 'enabled' when the time specified by trapControlPeriod expires. A management application may set the value to 'enabled' at any time, but must never set the value to 'enabledThrottled'.
Status: current Access: read-write
OBJECT-TYPE    
  RateStatus  

rfCharacteristicsTrapControlPeriod 1.3.6.1.4.1.2696.3.3.1.2.1.1.1.5
The agent will ensure that the interval between sending traps is no shorter than this time period (unless overridden by the manager).
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 0..3600000  

rfCharacteristicsTrapInput 1.3.6.1.4.1.2696.3.3.1.2.1.2
The Transport Stream input whose change triggered the current trap. This information can also be obtained by analysing the rfCharacteristicsTrapOID, but rfCharacteristicsTrapInput provides the information directly. This object is present for the formal purpose of defining the variable bindings returned with the traps. It is not accessible for normal reading.
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  InputNumber  

mgRFCharacteristicsTable 1.3.6.1.4.1.2696.3.3.1.2.2
The RF characteristics of the input signal. These values represent the measuring instrument's 'best effort' to determine them.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MgRFCharacteristicsEntry

mgRFCharacteristicsEntry 1.3.6.1.4.1.2696.3.3.1.2.2.1
Row specification
Status: current Access: not-accessible
OBJECT-TYPE    
  MgRFCharacteristicsEntry  

mgRFInputNumber 1.3.6.1.4.1.2696.3.3.1.2.2.1.1
The physical input on which these RF characteristics are found
Status: current Access: not-accessible
OBJECT-TYPE    
  InputNumber  

mgRFSystemType 1.3.6.1.4.1.2696.3.3.1.2.2.1.2
Which delivery system is in use: cable, satellite or terrestrial. The value of this object determines which other objects in this table have valid values.
Status: current Access: read-only
OBJECT-TYPE    
  DeliverySystemType  

mgRFCentreFrequency 1.3.6.1.4.1.2696.3.3.1.2.2.1.3
This is the centre frequency to which the measuring equipment is tuned. This frequency is the actual input frequency to the measuring equipment, which may be at an intermediate frequency (IF) rather than the final RF. Valid for: cable, satellite, terrestrial
Status: current Access: read-only
OBJECT-TYPE    
  FloatingPoint  

mgRFModulation 1.3.6.1.4.1.2696.3.3.1.2.2.1.4
The modulation scheme in use Valid for: cable, satellite, terrestrial
Status: current Access: read-only
OBJECT-TYPE    
  Modulation  

mgRFFecInner 1.3.6.1.4.1.2696.3.3.1.2.2.1.5
Inner Forward Error Correction scheme (also referred to as code rate). In the case of a hierarchical terrestrial transmission, this is the inner code rate for the high priority stream. Valid for: satellite, terrestrial
Status: current Access: read-only
OBJECT-TYPE    
  InnerCodeRate  

mgRFFecInnerLP 1.3.6.1.4.1.2696.3.3.1.2.2.1.6
Inner Forward Error Correction scheme (also referred to as code rate). This is the code rate for the low priority stream in a hierarchical terrestrial transmission. Valid for: terrestrial
Status: current Access: read-only
OBJECT-TYPE    
  InnerCodeRate  

mgRFSymbolRate 1.3.6.1.4.1.2696.3.3.1.2.2.1.7
Indicates the symbol rate of the transmission. Valid for: cable, satellite
Status: current Access: read-only
OBJECT-TYPE    
  FloatingPoint  

mgRFBandwidth 1.3.6.1.4.1.2696.3.3.1.2.2.1.8
Bandwidth of the signal. Normally this will be equivalent to the channel spacing. Valid for: terrestrial
Status: current Access: read-only
OBJECT-TYPE    
  FloatingPoint  

mgRFTransmissionMode 1.3.6.1.4.1.2696.3.3.1.2.2.1.9
Whether there are 2k or 8k carriers in the OFDM modulation scheme. Valid for: terrestrial
Status: current Access: read-only
OBJECT-TYPE    
  TerrestrialTransmissionMode  

mgRFIsHierarchical 1.3.6.1.4.1.2696.3.3.1.2.2.1.10
Whether the transmission is hierarchical Valid for: terrestrial
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

mgRFGuardInterval 1.3.6.1.4.1.2696.3.3.1.2.2.1.11
The guard interval in use Valid for: terrestrial
Status: current Access: read-only
OBJECT-TYPE    
  GuardInterval  

mgSignalCharacteristicsConformance 1.3.6.1.4.1.2696.3.3.2
OBJECT IDENTIFIER    

mgSignalCharacteristicsCompliances 1.3.6.1.4.1.2696.3.3.2.1
OBJECT IDENTIFIER    

mgSCTransportStreamCompliance 1.3.6.1.4.1.2696.3.3.2.1.1
An implementation which provides all the information in the mgTSStructure part of the MIB and implements the tsStructureChangeTrap can claim this conformance.
Status: current Access: read-only
MODULE-COMPLIANCE    

mgSCRadioFrequencyCompliance 1.3.6.1.4.1.2696.3.3.2.1.2
An implementation which provides all the information in the mgRFCharacteristics part of the MIB and implements the rfCharacteristicsChangeTrap can claim this conformance.
Status: current Access: read-only
MODULE-COMPLIANCE    

mgSignalCharacteristicsGroups 1.3.6.1.4.1.2696.3.3.2.3
OBJECT IDENTIFIER    

mgSCTransportStreamGroup 1.3.6.1.4.1.2696.3.3.2.3.1
This group contains all the objects in the mgTSStructure part of the MIB.
Status: current Access: read-only
OBJECT-GROUP    

mgSCRadioFrequencyGroup 1.3.6.1.4.1.2696.3.3.2.3.2
This group contains all the objects in the mgRFCharacteristics part of the MIB
Status: current Access: read-only
OBJECT-GROUP    

mgSCTransportStreamTrapGroup 1.3.6.1.4.1.2696.3.3.2.3.3
Contains tsStructureChangeTrap
Status: current Access: read-only
NOTIFICATION-GROUP    

mgSCRadioFrequencyTrapGroup 1.3.6.1.4.1.2696.3.3.2.3.4
Contains rfCharacteristicsChangeTrap
Status: current Access: read-only
NOTIFICATION-GROUP