DELL-RAC-MIB

File: DELL-RAC-MIB.mib (157381 bytes)

Imported modules

RFC1155-SMI RFC-1212 RFC-1215
RFC1213-MIB

Imported symbols

enterprises TimeTicks OBJECT-TYPE
TRAP-TYPE DisplayString

Defined Types

DellString  
DisplayString Size(0..1023)    

DellRacType  
INTEGER other(1), unknown(2), dracIII(3), era(4), drac4(5), drac5(6), drac5MC(7), cmc(8), idrac(9), vrtxCMC(18), fx2CMC(19)    

DellStatus  
INTEGER other(1), unknown(2), ok(3), nonCritical(4), critical(5), nonRecoverable(6)    

DellPowerReading  
DisplayString Size(0..32)    

DellCMCPowerIndexRange  
INTEGER 1..1    

DellCMCPSUIndexRange  
INTEGER 1..6    

DellCMCPSUCapable  
INTEGER absent(1), none(2), basic(3)    

DellTemperatureReading  
INTEGER    

DellTimestamp  
DisplayString Size(26)    

DellCMCServerIndexRange  
INTEGER 1..32    

DellCMCServerCapable  
INTEGER absent(1), none(2), basic(3), off(4)    

DrsCMCPowerTableEntry  
SEQUENCE    
  drsChassisIndex DellCMCPowerIndexRange
  drsPotentialPower DellPowerReading
  drsIdlePower DellPowerReading
  drsMaxPowerSpecification DellPowerReading
  drsPowerSurplus DellPowerReading
  drsKWhCumulative DellPowerReading
  drsKWhCumulativeTime DellTimestamp
  drsWattsPeakUsage DellPowerReading
  drsWattsPeakTime DellTimestamp
  drsWattsMinUsage DellPowerReading
  drsWattsMinTime DellTimestamp
  drsWattsResetTime DellTimestamp
  drsWattsReading DellPowerReading
  drsAmpsReading DellPowerReading

DrsCMCPSUTableEntry  
SEQUENCE    
  drsPSUChassisIndex DellCMCPowerIndexRange
  drsPSUIndex DellCMCPSUIndexRange
  drsPSULocation DellString
  drsPSUMonitoringCapable DellCMCPSUCapable
  drsPSUVoltsReading DellPowerReading
  drsPSUAmpsReading DellPowerReading
  drsPSUWattsReading DellPowerReading

DrsCMCServerTableEntry  
SEQUENCE    
  drsServerIndex DellCMCServerIndexRange
  drsServerMonitoringCapable DellCMCServerCapable
  drsServerServiceTag DellString
  drsServerSlotName DellString
  drsServerSlotNumber DellString
  drsServerNodeID DellString

Defined Values

dell 1.3.6.1.4.1.674
OBJECT IDENTIFIER    

server3 1.3.6.1.4.1.674.10892
OBJECT IDENTIFIER    

drsOutofBandGroup 1.3.6.1.4.1.674.10892.2
OBJECT IDENTIFIER    

drsInformationGroup 1.3.6.1.4.1.674.10892.2.1
OBJECT IDENTIFIER    

drsProductInfoGroup 1.3.6.1.4.1.674.10892.2.1.1
OBJECT IDENTIFIER    

drsFirmwareGroup 1.3.6.1.4.1.674.10892.2.1.2
OBJECT IDENTIFIER    

drsStatusGroup 1.3.6.1.4.1.674.10892.2.2
OBJECT IDENTIFIER    

drsChassisStatusGroup 1.3.6.1.4.1.674.10892.2.3
OBJECT IDENTIFIER    

drsStatusNowGroup 1.3.6.1.4.1.674.10892.2.3.1
OBJECT IDENTIFIER    

drsStatusPrevGroup 1.3.6.1.4.1.674.10892.2.3.2
OBJECT IDENTIFIER    

drsStatusChangeGroup 1.3.6.1.4.1.674.10892.2.3.3
OBJECT IDENTIFIER    

drsChassisPowerGroup 1.3.6.1.4.1.674.10892.2.4
OBJECT IDENTIFIER    

drsChassisServerGroup 1.3.6.1.4.1.674.10892.2.5
OBJECT IDENTIFIER    

drsCMCAlertGroup 1.3.6.1.4.1.674.10892.2.20
OBJECT IDENTIFIER    

drsChassisAlertVariables 1.3.6.1.4.1.674.10892.2.20.10
OBJECT IDENTIFIER    

drsCMCAlert2Group 1.3.6.1.4.1.674.10892.2.21
OBJECT IDENTIFIER    

drsChassisAlert2Variables 1.3.6.1.4.1.674.10892.2.21.10
OBJECT IDENTIFIER    

drsAlertGroup 1.3.6.1.4.1.674.10892.2.5000
OBJECT IDENTIFIER    

drsAlertVariables 1.3.6.1.4.1.674.10892.2.5000.10
OBJECT IDENTIFIER    

drsProductName 1.3.6.1.4.1.674.10892.2.1.1.1
0001.0001.0001 This attribute defines the product name of a chassis management controller.
OBJECT-TYPE    
  DellString  

drsProductShortName 1.3.6.1.4.1.674.10892.2.1.1.2
0001.0001.0002 This attribute defines the short product name of a chassis management controller.
OBJECT-TYPE    
  DellString  

drsProductDescription 1.3.6.1.4.1.674.10892.2.1.1.3
0001.0001.0003 This attribute defines the product description of a chassis management controller.
OBJECT-TYPE    
  DellString  

drsProductManufacturer 1.3.6.1.4.1.674.10892.2.1.1.4
0001.0001.0004 This attribute defines the product manufacturer of a chassis management controller.
OBJECT-TYPE    
  DellString  

drsProductVersion 1.3.6.1.4.1.674.10892.2.1.1.5
0001.0001.0005 This attribute defines the product version of a chassis management controller.
OBJECT-TYPE    
  DellString  

drsChassisServiceTag 1.3.6.1.4.1.674.10892.2.1.1.6
0001.0001.0007 This attribute defines the Service Tag of the chassis.
OBJECT-TYPE    
  DellString  

drsProductURL 1.3.6.1.4.1.674.10892.2.1.1.7
0001.0001.0006 This attribute defines the out-of-band UI URL of a chassis management controller.
OBJECT-TYPE    
  DellString  

drsProductChassisAssetTag 1.3.6.1.4.1.674.10892.2.1.1.8
0001.0001.0008 This attribute defines the Asset Tag of the chassis.
OBJECT-TYPE    
  DellString  

drsProductChassisLocation 1.3.6.1.4.1.674.10892.2.1.1.9
0001.0001.0009 This attribute defines the location of the chassis.
OBJECT-TYPE    
  DellString  

drsProductChassisName 1.3.6.1.4.1.674.10892.2.1.1.10
0001.0001.0010 This attribute defines the name of the chassis.
OBJECT-TYPE    
  DellString  

drsSystemServiceTag 1.3.6.1.4.1.674.10892.2.1.1.11
0001.0001.0011 This attribute defines the service tag of a system.
OBJECT-TYPE    
  DellString  

drsProductSystemAssetTag 1.3.6.1.4.1.674.10892.2.1.1.12
0001.0001.0012 This attribute defines the asset tag of a system.
OBJECT-TYPE    
  DellString  

drsProductSystemSlot 1.3.6.1.4.1.674.10892.2.1.1.13
0001.0001.0013 This attribute defines the slot number of a CMC.
OBJECT-TYPE    
  DellString  

drsProductType 1.3.6.1.4.1.674.10892.2.1.1.14
0001.0001.0014 This attribute defines type of a remote access card
OBJECT-TYPE    
  DellRacType  

drsProductChassisDataCenter 1.3.6.1.4.1.674.10892.2.1.1.15
0001.0001.0015 This attribute defines the Data Center locator of the chassis.
OBJECT-TYPE    
  DellString  

drsProductChassisAisle 1.3.6.1.4.1.674.10892.2.1.1.16
0001.0001.0016 This attribute defines the Aisle locator of the chassis.
OBJECT-TYPE    
  DellString  

drsProductChassisRack 1.3.6.1.4.1.674.10892.2.1.1.17
0001.0001.0017 This attribute defines the Rack locator of the chassis.
OBJECT-TYPE    
  DellString  

drsProductChassisRackSlot 1.3.6.1.4.1.674.10892.2.1.1.18
0001.0001.0018 This attribute defines the Rack Slot locator of the chassis.
OBJECT-TYPE    
  DellString  

drsProductChassisModel 1.3.6.1.4.1.674.10892.2.1.1.19
0001.0001.0019 This attribute defines the Model of the chassis.
OBJECT-TYPE    
  DellString  

drsProductChassisExpressServiceCode 1.3.6.1.4.1.674.10892.2.1.1.20
0001.0001.0020 This attribute defines the Express Service Code of the chassis.
OBJECT-TYPE    
  DellString  

drsProductChassisSystemID 1.3.6.1.4.1.674.10892.2.1.1.21
0001.0001.0021 This attribute defines the System ID of the chassis.
OBJECT-TYPE    
  INTEGER  

drsProductChassisSize 1.3.6.1.4.1.674.10892.2.1.1.22
0001.0001.0022 This attribute defines the size of the chassis in rack units (U). A U is a standard unit of measure for the height of a rack or rack-mountable component.
OBJECT-TYPE    
  INTEGER  

drsFirmwareVersion 1.3.6.1.4.1.674.10892.2.1.2.1
0001.0002.0001 This attribute defines the firmware version of chassis management controller 1.
OBJECT-TYPE    
  DellString  

drsiKVMFirmwareVersion 1.3.6.1.4.1.674.10892.2.1.2.2
0001.0002.0002 This attribute defines the firmware version of the iKVM.
OBJECT-TYPE    
  DellString  

drsFirmwareVersion2 1.3.6.1.4.1.674.10892.2.1.2.3
0001.0002.0003 This attribute defines the firmware version of chassis management controller 2.
OBJECT-TYPE    
  DellString  

drsGlobalSystemStatus 1.3.6.1.4.1.674.10892.2.2.1
0002.0001.0001 This attribute defines the overall chassis status being monitored by the chassis management card.
OBJECT-TYPE    
  DellStatus  

drsGlobalCurrStatus 1.3.6.1.4.1.674.10892.2.3.1.1
0003.0001.0001 This attribute defines the overall chassis status being monitored by the chassis management card.
OBJECT-TYPE    
  DellStatus  

drsIOMCurrStatus 1.3.6.1.4.1.674.10892.2.3.1.2
0003.0001.0002 This attribute defines the IOM subsystem status being monitored by the chassis management card.
OBJECT-TYPE    
  DellStatus  

drsKVMCurrStatus 1.3.6.1.4.1.674.10892.2.3.1.3
0003.0001.0003 This attribute defines the iKVM subsystem health status being monitored by the chassis management card.
OBJECT-TYPE    
  DellStatus  

drsRedCurrStatus 1.3.6.1.4.1.674.10892.2.3.1.4
0003.0001.0004 This attribute defines the Redundancy status being monitored by the chassis management card.
OBJECT-TYPE    
  DellStatus  

drsPowerCurrStatus 1.3.6.1.4.1.674.10892.2.3.1.5
0003.0001.0005 This attribute defines the power subsystem health status being monitored by the chassis management card.
OBJECT-TYPE    
  DellStatus  

drsFanCurrStatus 1.3.6.1.4.1.674.10892.2.3.1.6
0003.0001.0006 This attribute defines the Fan subsystem health status being monitored by the chassis management card.
OBJECT-TYPE    
  DellStatus  

drsBladeCurrStatus 1.3.6.1.4.1.674.10892.2.3.1.7
0003.0001.0007 This attribute defines the Blade subsystem health status being monitored by the chassis management card.
OBJECT-TYPE    
  DellStatus  

drsTempCurrStatus 1.3.6.1.4.1.674.10892.2.3.1.8
0003.0001.0008 This attribute defines the Temp Sensor subsystem health status being monitored by the chassis management card.
OBJECT-TYPE    
  DellStatus  

drsCMCCurrStatus 1.3.6.1.4.1.674.10892.2.3.1.9
0003.0001.0009 This attribute defines the CMC health status being monitored by the chassis management card.
OBJECT-TYPE    
  DellStatus  

drsChassisFrontPanelAmbientTemperature 1.3.6.1.4.1.674.10892.2.3.1.10
0003.0001.0010 This attribute defines the ambient temperature reading (in degrees Celsius) for the chassis front panel controller.
OBJECT-TYPE    
  DellTemperatureReading  

drsCMCAmbientTemperature 1.3.6.1.4.1.674.10892.2.3.1.11
0003.0001.0011 This attribute defines the ambient temperature reading (in degrees Celsius) for the chassis management card.
OBJECT-TYPE    
  DellTemperatureReading  

drsCMCProcessorTemperature 1.3.6.1.4.1.674.10892.2.3.1.12
0003.0001.0012 This attribute defines the temperature reading (in degrees Celsius) for the chassis management card processor.
OBJECT-TYPE    
  DellTemperatureReading  

drsGlobalPrevStatus 1.3.6.1.4.1.674.10892.2.3.2.1
0003.0002.0001 This attribute defines the previous chassis status recorded by the chassis management card.
OBJECT-TYPE    
  DellStatus  

drsIOMPrevStatus 1.3.6.1.4.1.674.10892.2.3.2.2
0003.0002.0002 This attribute defines the previous IOM subsystem status recorded by the chassis management card.
OBJECT-TYPE    
  DellStatus  

drsKVMPrevStatus 1.3.6.1.4.1.674.10892.2.3.2.3
0003.0002.0003 This attribute defines the previous iKVM subsystem health status recorded by the chassis management card.
OBJECT-TYPE    
  DellStatus  

drsRedPrevStatus 1.3.6.1.4.1.674.10892.2.3.2.4
0003.0002.0004 This attribute defines the previous Redundancy status recorded by the chassis management card.
OBJECT-TYPE    
  DellStatus  

drsPowerPrevStatus 1.3.6.1.4.1.674.10892.2.3.2.5
0003.0002.0005 This attribute defines the previous power subsystem health status recorded by the chassis management card.
OBJECT-TYPE    
  DellStatus  

drsFanPrevStatus 1.3.6.1.4.1.674.10892.2.3.2.6
0003.0002.0006 This attribute defines the previous Fan health status being monitored by the chassis management card.
OBJECT-TYPE    
  DellStatus  

drsBladePrevStatus 1.3.6.1.4.1.674.10892.2.3.2.7
0003.0002.0007 This attribute defines the previous Blade subsystem health status recorded by the chassis management card.
OBJECT-TYPE    
  DellStatus  

drsTempPrevStatus 1.3.6.1.4.1.674.10892.2.3.2.8
0003.0001.0008 This attribute defines the Temp Sensor health status being monitored by the chassis management card.
OBJECT-TYPE    
  DellStatus  

drsCMCPrevStatus 1.3.6.1.4.1.674.10892.2.3.2.9
0003.0001.0009 This attribute defines the CMC health status being monitored by the chassis management card.
OBJECT-TYPE    
  DellStatus  

drsGlobalChangeTime 1.3.6.1.4.1.674.10892.2.3.3.1
0003.0003.0001 This attribute defines the timestamp of the most recent global status change.
OBJECT-TYPE    
  TimeTicks  

drsIOMChangeTime 1.3.6.1.4.1.674.10892.2.3.3.2
0003.0003.0002 This attribute defines the timestamp of the most recent IOM status change.
OBJECT-TYPE    
  TimeTicks  

drsKVMChangeTime 1.3.6.1.4.1.674.10892.2.3.3.3
0003.0003.0003 This attribute defines the timestamp of the most recent iKVM status change.
OBJECT-TYPE    
  TimeTicks  

drsRedChangeTime 1.3.6.1.4.1.674.10892.2.3.3.4
0003.0003.0004 This attribute defines the timestamp of the most recent Redundancy status change.
OBJECT-TYPE    
  TimeTicks  

drsPowerChangeTime 1.3.6.1.4.1.674.10892.2.3.3.5
0003.0003.0005 This attribute defines the timestamp of the most recent power health status change.
OBJECT-TYPE    
  TimeTicks  

drsFanChangeTime 1.3.6.1.4.1.674.10892.2.3.3.6
0003.0003.0006 This attribute defines the timestamp of the most recent Fan health status change.
OBJECT-TYPE    
  TimeTicks  

drsBladeChangeTime 1.3.6.1.4.1.674.10892.2.3.3.7
0003.0003.0007 This attribute defines the timestamp of the most recent Blade health status change.
OBJECT-TYPE    
  TimeTicks  

drsTempChangeTime 1.3.6.1.4.1.674.10892.2.3.3.8
0003.0003.0008 This attribute defines the timestamp of the most recent Temp Sensor health status change.
OBJECT-TYPE    
  TimeTicks  

drsCMCChangeTime 1.3.6.1.4.1.674.10892.2.3.3.9
0003.0003.0009 This attribute defines the timestamp of the most recent CMC health status change.
OBJECT-TYPE    
  TimeTicks  

drsCMCPowerTable 1.3.6.1.4.1.674.10892.2.4.1
0004.0001 This object defines the CMC power table.
OBJECT-TYPE    
  SEQUENCE OF  
    DrsCMCPowerTableEntry

drsCMCPowerTableEntry 1.3.6.1.4.1.674.10892.2.4.1.1
0004.0001.0001 This object defines the CMC power table entry.
OBJECT-TYPE    
  DrsCMCPowerTableEntry  

drsCMCPSUTable 1.3.6.1.4.1.674.10892.2.4.2
0004.0002 This object defines the CMC PSU table.
OBJECT-TYPE    
  SEQUENCE OF  
    DrsCMCPSUTableEntry

drsCMCPSUTableEntry 1.3.6.1.4.1.674.10892.2.4.2.1
0004.0002.0001 This object defines the CMC PSU table entry.
OBJECT-TYPE    
  DrsCMCPSUTableEntry  

drsChassisIndex 1.3.6.1.4.1.674.10892.2.4.1.1.1
0004.0001.0001.0001 This attribute defines the index (one-based) of the associated chassis.
OBJECT-TYPE    
  DellCMCPowerIndexRange  

drsPotentialPower 1.3.6.1.4.1.674.10892.2.4.1.1.2
0004.0001.0001.0002 This attribute defines the power (in Watts) required by the chassis infrastructure, plus the sum of the maximum power requirements for all currently powered-on servers.
OBJECT-TYPE    
  DellPowerReading  

drsIdlePower 1.3.6.1.4.1.674.10892.2.4.1.1.3
0004.0001.0001.0003 This attribute defines the power (in Watts) required by the chassis infrastructure, plus the sum of the minimum power requirements for all currently powered-on servers.
OBJECT-TYPE    
  DellPowerReading  

drsMaxPowerSpecification 1.3.6.1.4.1.674.10892.2.4.1.1.4
0004.0001.0001.0004 This attribute defines the power limit (in Watts) at which server throttling will take place.
OBJECT-TYPE    
  DellPowerReading  

drsPowerSurplus 1.3.6.1.4.1.674.10892.2.4.1.1.5
0004.0001.0001.0005 This attribute defines the power surplus (in Watts) remaining above the drsPotentialPower reading.
OBJECT-TYPE    
  DellPowerReading  

drsKWhCumulative 1.3.6.1.4.1.674.10892.2.4.1.1.6
0004.0001.0001.0006 This attribute defines the cumulative chassis power usage (in KWh) since last reset.
OBJECT-TYPE    
  DellPowerReading  

drsKWhCumulativeTime 1.3.6.1.4.1.674.10892.2.4.1.1.7
0004.0001.0001.0007 This attribute defines the timestamp of the most recent chassis power accumulator reset.
OBJECT-TYPE    
  DellTimestamp  

drsWattsPeakUsage 1.3.6.1.4.1.674.10892.2.4.1.1.8
0004.0001.0001.0008 This attribute defines the chassis peak power usage (in Watts) since last reset.
OBJECT-TYPE    
  DellPowerReading  

drsWattsPeakTime 1.3.6.1.4.1.674.10892.2.4.1.1.9
0004.0001.0001.0009 This attribute defines the timestamp of the most recent chassis peak power usage.
OBJECT-TYPE    
  DellTimestamp  

drsWattsMinUsage 1.3.6.1.4.1.674.10892.2.4.1.1.10
0004.0001.0001.0010 This attribute defines the chassis mimimum power usage (in Watts) since last reset.
OBJECT-TYPE    
  DellPowerReading  

drsWattsMinTime 1.3.6.1.4.1.674.10892.2.4.1.1.11
0004.0001.0001.0011 This attribute defines the timestamp of the most recent chassis minimum power usage.
OBJECT-TYPE    
  DellTimestamp  

drsWattsResetTime 1.3.6.1.4.1.674.10892.2.4.1.1.12
0004.0001.0001.0012 This attribute defines the timestamp of the most recent reset of the chassis min/peak Watts readings.
OBJECT-TYPE    
  DellTimestamp  

drsWattsReading 1.3.6.1.4.1.674.10892.2.4.1.1.13
0004.0001.0001.0013 This attribute defines the instantaneous chassis power usage (in Watts).
OBJECT-TYPE    
  DellPowerReading  

drsAmpsReading 1.3.6.1.4.1.674.10892.2.4.1.1.14
0004.0001.0001.0014 This attribute defines the instantaneous chassis current usage (in Watts).
OBJECT-TYPE    
  DellPowerReading  

drsPSUChassisIndex 1.3.6.1.4.1.674.10892.2.4.2.1.1
0004.0002.0001.0001 This attribute defines the index (one-based) of the associated chassis.
OBJECT-TYPE    
  DellCMCPowerIndexRange  

drsPSUIndex 1.3.6.1.4.1.674.10892.2.4.2.1.2
0004.0002.0001.0002 This attribute defines the index (one-based) of the associated CMC PSU.
OBJECT-TYPE    
  DellCMCPSUIndexRange  

drsPSULocation 1.3.6.1.4.1.674.10892.2.4.2.1.3
0004.0002.0001.0003 This attribute defines the location of the CMC PSU.
OBJECT-TYPE    
  DellString  

drsPSUMonitoringCapable 1.3.6.1.4.1.674.10892.2.4.2.1.4
0004.0002.0001.0004 This attribute defines the PSU Monitoring capabilities, or the absence of a PSU in this location.
OBJECT-TYPE    
  DellCMCPSUCapable  

drsPSUVoltsReading 1.3.6.1.4.1.674.10892.2.4.2.1.5
0004.0002.0001.0005 This attribute defines the instantaneous PSU Voltage reading.
OBJECT-TYPE    
  DellPowerReading  

drsPSUAmpsReading 1.3.6.1.4.1.674.10892.2.4.2.1.6
0004.0002.0001.0006 This attribute defines the instantaneous PSU Current reading.
OBJECT-TYPE    
  DellPowerReading  

drsPSUWattsReading 1.3.6.1.4.1.674.10892.2.4.2.1.7
0004.0002.0001.0007 This attribute defines the instantaneous PSU Wattage reading.
OBJECT-TYPE    
  DellPowerReading  

drsCMCServerTable 1.3.6.1.4.1.674.10892.2.5.1
0005.0001 This object defines the CMC server table.
OBJECT-TYPE    
  SEQUENCE OF  
    DrsCMCServerTableEntry

drsCMCServerTableEntry 1.3.6.1.4.1.674.10892.2.5.1.1
0005.0001.0001 This object defines the CMC server table entry.
OBJECT-TYPE    
  DrsCMCServerTableEntry  

drsServerIndex 1.3.6.1.4.1.674.10892.2.5.1.1.1
0005.0001.0001.0001 This attribute defines the index (one-based) of the associated CMC server.
OBJECT-TYPE    
  DellCMCServerIndexRange  

drsServerMonitoringCapable 1.3.6.1.4.1.674.10892.2.5.1.1.2
0005.0001.0001.0002 This attribute defines the server monitoring capabilities, or the absence of a server in this location.
OBJECT-TYPE    
  DellCMCServerCapable  

drsServerServiceTag 1.3.6.1.4.1.674.10892.2.5.1.1.3
0005.0001.0001.0003 This attribute defines the Service Tag of the CMC server.
OBJECT-TYPE    
  DellString  

drsServerSlotName 1.3.6.1.4.1.674.10892.2.5.1.1.4
0005.0001.0001.0004 This attribute defines the Slot Name of the CMC server.
OBJECT-TYPE    
  DellString  

drsServerSlotNumber 1.3.6.1.4.1.674.10892.2.5.1.1.5
0005.0001.0001.0005 This attribute defines the Chassis Slot Number of the CMC server.
OBJECT-TYPE    
  DellString  

drsServerNodeID 1.3.6.1.4.1.674.10892.2.5.1.1.6
0005.0001.0001.0006 This attribute defines the Node ID of the CMC server. The Node ID provides a unique identifier for the server.
OBJECT-TYPE    
  DellString  

drsCASubSystem 1.3.6.1.4.1.674.10892.2.20.10.1
0020.0010.0001 This attribute defines the Sub-System Name of the CMC Alert
OBJECT-TYPE    
  DellString  

drsCASSCurrStatus 1.3.6.1.4.1.674.10892.2.20.10.2
0020.0010.0002 This attribute defines the Current Status of the Alerting Sub-System
OBJECT-TYPE    
  DellStatus  

drsCASSPrevStatus 1.3.6.1.4.1.674.10892.2.20.10.3
0020.0010.0003 This attribute defines the Previous Status of the Alerting Sub-System
OBJECT-TYPE    
  DellStatus  

drsCASSChangeTime 1.3.6.1.4.1.674.10892.2.20.10.4
0020.0010.0004 This attribute defines the Timestamp of Most Recent Change of the Alerting Sub-System
OBJECT-TYPE    
  TimeTicks  

drsCAMessage 1.3.6.1.4.1.674.10892.2.20.10.5
0020.0010.0005 This attribute defines the CSSD message of the CMC Alert
OBJECT-TYPE    
  DellString  

drsCA2MessageID 1.3.6.1.4.1.674.10892.2.21.10.1
Message ID of the alert.
OBJECT-TYPE    
  DisplayString Size(0..8)  

drsCA2Message 1.3.6.1.4.1.674.10892.2.21.10.2
Message describing the alert.
OBJECT-TYPE    
  DellString  

drsCA2MessageArgs 1.3.6.1.4.1.674.10892.2.21.10.3
Concatenated set of strings representing any message arguments that were used to construct the alert message. Each message argument string is enclosed in double quotes, and there is a comma after the ending double quote of each message argument string, except the last one. Any double quotes found within a message argument string were preprocessed and changed to single quotes.
OBJECT-TYPE    
  DellString  

drsCA2AlertStatus 1.3.6.1.4.1.674.10892.2.21.10.4
Status of the alert.
OBJECT-TYPE    
  DellStatus  

drsCA2FQDD 1.3.6.1.4.1.674.10892.2.21.10.5
Fully qualified device descriptor of device causing the alert.
OBJECT-TYPE    
  DisplayString Size(0..512)  

drsAlertSystem 1.3.6.1.4.1.674.10892.2.5000.10.1
5000.0010.0001 Name of the system generating the alert.
OBJECT-TYPE    
  STRING Size(0..255)  

drsAlertTableIndexOID 1.3.6.1.4.1.674.10892.2.5000.10.2
5000.0010.0002 0.0
OBJECT-TYPE    
  OBJECT IDENTIFIER  

drsAlertMessage 1.3.6.1.4.1.674.10892.2.5000.10.3
5000.0010.0003 Message describing the alert.
OBJECT-TYPE    
  STRING Size(0..1024)  

drsAlertCurrentStatus 1.3.6.1.4.1.674.10892.2.5000.10.4
5000.0010.0004 Current status of object causing the alert.
OBJECT-TYPE    
  DellStatus  

drsAlertPreviousStatus 1.3.6.1.4.1.674.10892.2.5000.10.5
5000.0010.0005 Previous status of object causing the alert.
OBJECT-TYPE    
  DellStatus  

drsAlertData 1.3.6.1.4.1.674.10892.2.5000.10.6
5000.0010.0006 Alert data.
OBJECT-TYPE    
  STRING Size(0..1024)