CXModuleHardware-MIB

File: CXModuleHardware-MIB.mib (5026 bytes)

Imported modules

RFC1155-SMI RFC-1212 RFC1213-MIB
CXProduct-SMI

Imported symbols

TimeTicks OBJECT-TYPE DisplayString
cxModuleHardware Alias

Defined Values

cxModuleHwAlias 1.3.6.1.4.1.495.2.1.5.1.1
Determines the name the network administrator assigns to the CPU card. When you configure via the local console, this name is the command prompt. The setting of this object is dynamic. The system immediately implements the name you choose. Range of Values: From 1 to 32 alphanumeric characters. You can use any combination of lettersor numbers; however, you cannot use blank spaces. Use a dash or underscore as a delimiter. Default value: - CX900 architecture: CX900 - CX1000 architecture: CX1000 Configuration Changed: Operative
Status: mandatory Access: read-write
OBJECT-TYPE    
  Alias  

cxModuleHwRevAssemblyAndEco 1.3.6.1.4.1.495.2.1.5.1.2
Displays the hardware revision of the device. You cannot modify this object. It is a display that the software provides. Range of Values: 7 numeric bits Default Value: None
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cxModuleHwPhysSlot 1.3.6.1.4.1.495.2.1.5.1.3
Displays the number of the physical slot where the CPU card resides. You cannot modify this object. It is a display that the software provides. Note: THE CX 900 DOES NOT SUPPORT THIS OBJECT. Range of values: - CX900 architechture: Not supported - CX1000 architechture: From 1 to 16 Default value: None
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cxModuleHwCpuClockSpeed 1.3.6.1.4.1.495.2.1.5.1.4
Displays the CPU clock rate in Khz. You cannot modify this object. It is a display that the software provides. Range of Values: None. The value is hardcoded on the CPU. Default Value: 25000
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cxModuleHwLedsDisplay 1.3.6.1.4.1.495.2.1.5.1.5
Displays the status of the error LED. You cannot modify this object. It is a display that the software provides. Options: on: Error LED is on. off: Error LED is off. Default Value: None
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cxModuleHwFlashEpromSize 1.3.6.1.4.1.495.2.1.5.1.7
Dispays the size, in Kbytes, of the Flash EPROM. You cannot modify this object. It is a display that the software provides. Range of Values: A maximum of 4 digits from 1024 to 6144 Default Value: None
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cxModuleHwPrivateDramSize 1.3.6.1.4.1.495.2.1.5.1.8
Displays the size, in Kbytes, of the System DRAM. You cannot modify this object. It is a display that the software provides. Range of Values: A maximum of 5 digits from 512 to 33792 Default Value: None
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cxModuleHwSharedDramSize 1.3.6.1.4.1.495.2.1.5.1.9
Displays the size, in Kbytes, of the Data Buffer DRAM. You cannot modify this object. It is a display that the software provides. Range of Values: -A maximum of 5 digits from 512 to 33792 Default Value: None
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cxModuleHwUpTimeTicks 1.3.6.1.4.1.495.2.1.5.1.12
Displays the number of time ticks,in 10msec increments, since power up. You cannot modify this object. It is a display that the software provides. Range of Values: 0 to 4,294,967,295 Default Value: 0
Status: mandatory Access: read-only
OBJECT-TYPE    
  TimeTicks  

cxModuleHwResetTimeOut 1.3.6.1.4.1.495.2.1.5.1.13
Determines the length of delay, in seconds before next scheduled card reset. This type of reset saves the configuration before resetting. The setting of this object is dynamic. The system immediately begins reducing the value you enter. Range of Values: A maximum of 10 digits from 0 to 4,294,967,295 Default Value: 0 Configuration Changed: Operative
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

cxModuleHwSwVersion 1.3.6.1.4.1.495.2.1.5.1.14
Displays the textual string which identifies the software currently running on the device. You cannot modify this object. It is a display that the software provides.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

cxModuleHwNodeId 1.3.6.1.4.1.495.2.1.5.1.15
Identifies this system with an ID number. This parameter is used only for SKYDATA's connection management. Range of Values: 0 to 65,535 Default Value: None
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..65535