CTMMIB

File: CTMMIB.mib (16993 bytes)

Imported modules

RFC1155-SMI RFC-1212 RFC-1215

Imported symbols

enterprises OBJECT-TYPE TRAP-TYPE

Defined Values

lastmilegear 1.3.6.1.4.1.25868
OBJECT IDENTIFIER    

mibObjects 1.3.6.1.4.1.25868.1
OBJECT IDENTIFIER    

version 1.3.6.1.4.1.25868.1.1
Version of Web GUI - Version of Web GUI Interface currently running on CTM
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

site 1.3.6.1.4.1.25868.1.2
Site Name - Site name as stored on CTM
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

lastIP 1.3.6.1.4.1.25868.1.3
Last IP Address Login - Last IP address captured at Login Attempt
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

lastTime 1.3.6.1.4.1.25868.1.4
Last Time Login - Last time of Login attempt
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

nSats 1.3.6.1.4.1.25868.1.5
Number Satellites in View - Number of Satellites in view of GPS Receiver Antenna being used for timing calculations
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

pwrP 1.3.6.1.4.1.25868.1.6
Master Primary Power - Master ?1? = Power OK, ?0? = Power Off or Low
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

pwrS 1.3.6.1.4.1.25868.1.7
Master Secondary Power - Master ?1? = Power OK, ?0? = Power Off or Low
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cbTrip 1.3.6.1.4.1.25868.1.8
Master Circuit Breaker Trip Bit Code - Master Breaker Tripped Code: 1=Port 1, 2=Port2, 4=Port 3, 8=Port4, 16=Port5, 32=Port6, 64=Port7, 128=Port8 Example: Code 5 means Port 3 and Port 1 Tripped
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

tempC 1.3.6.1.4.1.25868.1.9
Master Temperature
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

voltsM1 1.3.6.1.4.1.25868.1.10
Master Primary Power In Voltage - In Tenths of a Volt
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

voltsM2 1.3.6.1.4.1.25868.1.11
Master Secondary Power In Voltage - In Tenths of a Volt
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

portOnM 1.3.6.1.4.1.25868.1.12
Master Ports ON Enabled Status - Master ?1? =Sync Enabled, ?0? = Sync Off listed in order ?Port1?, ?Port2?, ?Port3?, ?Port4?, ?Port5?, ?Port6?, ?Port7?, ?Port8?
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

portSyncM 1.3.6.1.4.1.25868.1.13
Master Ports Sync Enabled Status - Master ?1? =Sync Enabled, ?0? = Sync Off listed in order ?Port1?, ?Port2?, ?Port3?, ?Port4?, ?Port5?, ?Port6?, ?Port7?, ?Port8?
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

portPwrM1 1.3.6.1.4.1.25868.1.14
Master Power Port 1 - (in tenths of a Watt) delivered on Port 1
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

portPwrM2 1.3.6.1.4.1.25868.1.15
Master Power Port 2 - (in tenths of a Watt) delivered on Port 2
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

portPwrM3 1.3.6.1.4.1.25868.1.16
Master Power Port 3 - (in tenths of a Watt) delivered on Port 3
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

portPwrM4 1.3.6.1.4.1.25868.1.17
Master Power Port 4 - (in tenths of a Watt) delivered on Port 4
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

portPwrM5 1.3.6.1.4.1.25868.1.18
Master Power Port 5 - (in tenths of a Watt) delivered on Port 5
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

portPwrM6 1.3.6.1.4.1.25868.1.19
Master Power Port 6 - (in tenths of a Watt) delivered on Port 6
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

portPwrM7 1.3.6.1.4.1.25868.1.20
Master Power Port 7 - (in tenths of a Watt) delivered on Port 7
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

portPwrM8 1.3.6.1.4.1.25868.1.21
Master Power Port 8 - (in tenths of a Watt) delivered on Port 8
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

modeReqM 1.3.6.1.4.1.25868.1.39
Master CTM2 Port Type Setting - Master ?00?=Type A (Canopy) ?10?=Type B (OFDM), ?01? = Type C (POE 802.3at), ?11? (POE 802.3at 4 Pair), ?100?=(POE 24V mode, CTM2 C Only) listed in order ?Port1?, ?Port2?, ?Port3?, ?Port4?, ?Port5?, ?Port6?, ?Port7?, ?Port8?
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

trpCntGM1 1.3.6.1.4.1.25868.1.45
Master Auto Restart Count Port 1 - Number of Times Auto Reset Feature has executed a Circuit Breaker Restart on Port 1
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

trpCntGM2 1.3.6.1.4.1.25868.1.46
Master Auto Restart Count Port 2 - Number of Times Auto Reset Feature has executed a Circuit Breaker Restart on Port 2
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

trpCntGM3 1.3.6.1.4.1.25868.1.47
Master Auto Restart Count Port 3 - Number of Times Auto Reset Feature has executed a Circuit Breaker Restart on Port 3
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

trpCntGM4 1.3.6.1.4.1.25868.1.48
Master Auto Restart Count Port 4 - Number of Times Auto Reset Feature has executed a Circuit Breaker Restart on Port 4
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

trpCntGM5 1.3.6.1.4.1.25868.1.49
Master Auto Restart Count Port 5 - Number of Times Auto Reset Feature has executed a Circuit Breaker Restart on Port 5
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

trpCntGM6 1.3.6.1.4.1.25868.1.50
Master Auto Restart Count Port 6 - Number of Times Auto Reset Feature has executed a Circuit Breaker Restart on Port 6
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

trpCntGM7 1.3.6.1.4.1.25868.1.51
Master Auto Restart Count Port 7 - Number of Times Auto Reset Feature has executed a Circuit Breaker Restart on Port 7
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

trpCntGM8 1.3.6.1.4.1.25868.1.52
Master Auto Restart Count Port 8 - Number of Times Auto Reset Feature has executed a Circuit Breaker Restart on Port 8
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

trpCntBM1 1.3.6.1.4.1.25868.1.53
Master Ckt Breaker Auto Restart Fail Count Port 1 - Number of Times Auto Reset Feature has failed to restart (after 7 tries) a Circuit Breaker on Port 1
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

trpCntBM2 1.3.6.1.4.1.25868.1.54
Master Ckt Breaker Auto Restart Fail Count Port 2 - Number of Times Auto Reset Feature has failed to restart (after 7 tries) a Circuit Breaker on Port 2
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

trpCntBM3 1.3.6.1.4.1.25868.1.55
Master Ckt Breaker Auto Restart Fail Count Port 3 - Number of Times Auto Reset Feature has failed to restart (after 7 tries) a Circuit Breaker on Port 3
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

trpCntBM4 1.3.6.1.4.1.25868.1.56
Master Ckt Breaker Auto Restart Fail Count Port 4 - Number of Times Auto Reset Feature has failed to restart (after 7 tries) a Circuit Breaker on Port 4
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

trpCntBM5 1.3.6.1.4.1.25868.1.57
Master Ckt Breaker Auto Restart Fail Count Port 5 - Number of Times Auto Reset Feature has failed to restart (after 7 tries) a Circuit Breaker on Port 5
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

trpCntBM6 1.3.6.1.4.1.25868.1.58
Master Ckt Breaker Auto Restart Fail Count Port 6 - Number of Times Auto Reset Feature has failed to restart (after 7 tries) a Circuit Breaker on Port 6
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

trpCntBM7 1.3.6.1.4.1.25868.1.59
Master Ckt Breaker Auto Restart Fail Count Port 7 - Number of Times Auto Reset Feature has failed to restart (after 7 tries) a Circuit Breaker on Port 7
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

trpCntBM8 1.3.6.1.4.1.25868.1.60
Master Ckt Breaker Auto Restart Fail Count Port 8 - Number of Times Auto Reset Feature has failed to restart (after 7 tries) a Circuit Breaker on Port 8
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

lostEthernetConnection 0
Lost Ethernet Connection
TRAP-TYPE    

masterPrimayPowerLost 1
Master Primary Power Lost
TRAP-TYPE    

masterSecondaryPowerLost 2
Master Secondary Power Lost
TRAP-TYPE    

gpsSignalLost 3
GPS Signal Lost
TRAP-TYPE    

masterTempatureError 4
Master Temperature Error
TRAP-TYPE    

masterCircuitBreakerTripCode 5
Master Circuit Breaker Trip Code - Master Breaker Tripped Code: 1=Port 1, 2=Port2, 4=Port 3, 8=Port4, 16=Port5, 32=Port6, 64=Port7, 128=Port8 Example: Code 5 means Port 3 and Port 1 Tripped
TRAP-TYPE    

loginFailedAttempt 6
Login Failed Attempt
TRAP-TYPE    

settingsChanged 7
CTM Settings Changed
TRAP-TYPE    

masterPrimaryPowerOK 10
Master Primary Power OK
TRAP-TYPE    

masterSecondaryPowerOK 20
Master Secondary Power OK
TRAP-TYPE    

gpsSignalOK 30
GPS Signal OK
TRAP-TYPE    

tempatureOK 40
Temperature OK
TRAP-TYPE    

circuitBreakersOK 50
Circuit Breakers OK
TRAP-TYPE    

masterAutoRestartCBCompletedOK 52
Master Auto Restart CB Completed OK
TRAP-TYPE    

loginOK 60
Login OK
TRAP-TYPE    

resetComplete 80
Reset Complete
TRAP-TYPE    

ethernetConnectionRestored 99
Ethernet Connection Restored
TRAP-TYPE