CPQSTSYS-MIB

File: CPQSTSYS-MIB.mib (144170 bytes)

Imported modules

CPQHOST-MIB RFC1155-SMI RFC1213-MIB
RFC-1212 RFC-1215

Imported symbols

compaq Counter DisplayString
OBJECT-TYPE TRAP-TYPE sysName
cpqHoTrapFlags

Defined Types

CpqSsDrvBoxEntry  
SEQUENCE    
  cpqSsBoxCntlrIndex INTEGER
  cpqSsBoxBusIndex INTEGER
  cpqSsBoxType INTEGER
  cpqSsBoxModel DisplayString
  cpqSsBoxFWRev DisplayString
  cpqSsBoxVendor DisplayString
  cpqSsBoxFanStatus INTEGER
  cpqSsBoxCondition INTEGER
  cpqSsBoxTempStatus INTEGER
  cpqSsBoxSidePanelStatus INTEGER
  cpqSsBoxFltTolPwrSupplyStatus INTEGER
  cpqSsBoxBackPlaneVersion INTEGER
  cpqSsBoxTotalBays INTEGER
  cpqSsBoxPlacement INTEGER
  cpqSsBoxDuplexOption INTEGER
  cpqSsBoxBoardRevision INTEGER
  cpqSsBoxSerialNumber DisplayString
  cpqSsBoxCntlrHwLocation DisplayString
  cpqSsBoxBackplaneSpeed INTEGER
  cpqSsBoxConnectionType INTEGER
  cpqSsBoxHostConnector DisplayString
  cpqSsBoxBoxOnConnector INTEGER
  cpqSsBoxLocationString DisplayString
  cpqSsBoxInitiatorSasAddress DisplayString
  cpqSsBoxTargetSasAddress DisplayString
  cpqSsBoxLocalManageIpAddress DisplayString
  cpqSsBoxPartnerManageIpAddress DisplayString
  cpqSsBoxConnectionStatus INTEGER
  cpqSsBoxTargetBasedManagement INTEGER

CpqSsChassisEntry  
SEQUENCE    
  cpqSsChassisIndex INTEGER
  cpqSsChassisConnectionType INTEGER
  cpqSsChassisSerialNumber DisplayString
  cpqSsChassisName DisplayString
  cpqSsChassisSystemBoardSerNum DisplayString
  cpqSsChassisSystemBoardRev DisplayString
  cpqSsChassisPowerBoardSerNum DisplayString
  cpqSsChassisPowerBoardRev DisplayString
  cpqSsChassisScsiBoardSerNum DisplayString
  cpqSsChassisScsiBoardRev DisplayString
  cpqSsChassisOverallCondition INTEGER
  cpqSsChassisPowerSupplyCondition INTEGER
  cpqSsChassisFanCondition INTEGER
  cpqSsChassisTemperatureCondition INTEGER
  cpqSsChassisFcaCntlrCondition INTEGER
  cpqSsChassisFcaLogicalDriveCondition INTEGER
  cpqSsChassisFcaPhysDrvCondition INTEGER
  cpqSsChassisTime INTEGER
  cpqSsChassisModel INTEGER
  cpqSsChassisBackplaneCondition INTEGER
  cpqSsChassisFcaTapeDrvCondition INTEGER
  cpqSsChassisRsoStatus INTEGER
  cpqSsChassisRsoCondition INTEGER
  cpqSsChassisScsiIoModuleType INTEGER
  cpqSsChassisPreferredPathMode INTEGER
  cpqSsChassisProductId DisplayString

CpqSsIoSlotEntry  
SEQUENCE    
  cpqSsIoSlotChassisIndex INTEGER
  cpqSsIoSlotIndex INTEGER
  cpqSsIoSlotControllerType INTEGER

CpqSsPowerSupplyEntry  
SEQUENCE    
  cpqSsPowerSupplyChassisIndex INTEGER
  cpqSsPowerSupplyIndex INTEGER
  cpqSsPowerSupplyBay INTEGER
  cpqSsPowerSupplyStatus INTEGER
  cpqSsPowerSupplyUpsStatus INTEGER
  cpqSsPowerSupplyCondition INTEGER
  cpqSsPowerSupplySerialNumber DisplayString
  cpqSsPowerSupplyBoardRevision DisplayString
  cpqSsPowerSupplyFirmwareRevision DisplayString

CpqSsFanModuleEntry  
SEQUENCE    
  cpqSsFanModuleChassisIndex INTEGER
  cpqSsFanModuleIndex INTEGER
  cpqSsFanModuleStatus INTEGER
  cpqSsFanModuleCondition INTEGER
  cpqSsFanModuleLocation INTEGER
  cpqSsFanModuleSerialNumber DisplayString
  cpqSsFanModuleBoardRevision DisplayString

CpqSsTempSensorEntry  
SEQUENCE    
  cpqSsTempSensorChassisIndex INTEGER
  cpqSsTempSensorIndex INTEGER
  cpqSsTempSensorStatus INTEGER
  cpqSsTempSensorCondition INTEGER
  cpqSsTempSensorLocation INTEGER
  cpqSsTempSensorCurrentValue INTEGER
  cpqSsTempSensorLimitValue INTEGER
  cpqSsTempSensorHysteresisValue INTEGER

CpqSsBackplaneEntry  
SEQUENCE    
  cpqSsBackplaneChassisIndex INTEGER
  cpqSsBackplaneIndex INTEGER
  cpqSsBackplaneFWRev DisplayString
  cpqSsBackplaneDriveBays INTEGER
  cpqSsBackplaneDuplexOption INTEGER
  cpqSsBackplaneCondition INTEGER
  cpqSsBackplaneVersion INTEGER
  cpqSsBackplaneVendor DisplayString
  cpqSsBackplaneModel DisplayString
  cpqSsBackplaneFanStatus INTEGER
  cpqSsBackplaneTempStatus INTEGER
  cpqSsBackplaneFtpsStatus INTEGER
  cpqSsBackplaneSerialNumber DisplayString
  cpqSsBackplanePlacement INTEGER
  cpqSsBackplaneBoardRevision INTEGER
  cpqSsBackplaneSpeed INTEGER
  cpqSsBackplaneConnectionType INTEGER
  cpqSsBackplaneConnector DisplayString
  cpqSsBackplaneOnConnector INTEGER
  cpqSsBackplaneLocationString DisplayString

CpqSsFibreAttachmentEntry  
SEQUENCE    
  cpqSsFibreAttachmentIndex INTEGER
  cpqSsFibreAttachmentHostControllerIndex INTEGER
  cpqSsFibreAttachmentHostControllerPort INTEGER
  cpqSsFibreAttachmentDeviceType INTEGER
  cpqSsFibreAttachmentDeviceIndex INTEGER
  cpqSsFibreAttachmentDevicePort INTEGER

CpqSsScsiAttachmentEntry  
SEQUENCE    
  cpqSsScsiAttachmentIndex INTEGER
  cpqSsScsiAttachmentControllerIndex INTEGER
  cpqSsScsiAttachmentControllerPort INTEGER
  cpqSsScsiAttachmentControllerTarget INTEGER
  cpqSsScsiAttachmentControllerLun INTEGER
  cpqSsScsiAttachmentChassisIndex INTEGER
  cpqSsScsiAttachmentChassisIoSlot INTEGER
  cpqSsScsiAttachmentPathStatus INTEGER
  cpqSsScsiAttachmentPathCondition INTEGER

CpqSsDrvBoxPathEntry  
SEQUENCE    
  cpqSsDrvBoxPathCntlrIndex INTEGER
  cpqSsDrvBoxPathBoxIndex INTEGER
  cpqSsDrvBoxPathIndex INTEGER
  cpqSsDrvBoxPathStatus INTEGER
  cpqSsDrvBoxPathCurrentRole INTEGER
  cpqSsDrvBoxPathHostConnector DisplayString
  cpqSsDrvBoxPathBoxOnConnector INTEGER
  cpqSsDrvBoxPathLocationString DisplayString

CpqSsTrapLogEntry  
SEQUENCE    
  cpqSsTrapLogIndex INTEGER
  cpqSsTrapType INTEGER
  cpqSsTrapTime OCTET STRING

CpqSsRaidSystemEntry  
SEQUENCE    
  cpqSsRaidSystemIndex INTEGER
  cpqSsRaidSystemName DisplayString
  cpqSsRaidSystemStatus INTEGER
  cpqSsRaidSystemCondition INTEGER
  cpqSsRaidSystemCntlr1SerialNumber DisplayString
  cpqSsRaidSystemCntlr2SerialNumber DisplayString

Defined Values

cpqSsStorageSys 1.3.6.1.4.1.232.8
OBJECT IDENTIFIER    

cpqSsMibRev 1.3.6.1.4.1.232.8.1
OBJECT IDENTIFIER    

cpqSsDrvBox 1.3.6.1.4.1.232.8.2
OBJECT IDENTIFIER    

cpqSsTrap 1.3.6.1.4.1.232.8.3
OBJECT IDENTIFIER    

cpqSsRaidSystem 1.3.6.1.4.1.232.8.4
OBJECT IDENTIFIER    

cpqSsBoxExtended 1.3.6.1.4.1.232.8.2.2
OBJECT IDENTIFIER    

cpqSsMibRevMajor 1.3.6.1.4.1.232.8.1.1
The Major Revision level. A change in the major revision level represents a major change in the architecture of the MIB. A change in the major revision level may indicate a significant change in the information supported and/or the meaning of the supported information, correct interpretation of data may require a MIB document with the same major revision level.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..65535  

cpqSsMibRevMinor 1.3.6.1.4.1.232.8.1.2
The Minor Revision level. A change in the minor revision level may represent some minor additional support; no changes to any pre-existing information has occurred.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..65535  

cpqSsMibCondition 1.3.6.1.4.1.232.8.1.3
The overall condition (status) of the system represented by this MIB.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(1), ok(2), degraded(3), failed(4)  

cpqSsDrvBoxTable 1.3.6.1.4.1.232.8.2.1
Drive Box Table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    CpqSsDrvBoxEntry

cpqSsDrvBoxEntry 1.3.6.1.4.1.232.8.2.1.1
Drive Box Entry.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  CpqSsDrvBoxEntry  

cpqSsBoxCntlrIndex 1.3.6.1.4.1.232.8.2.1.1.1
Drive Box Controller Index. The controller index indicates to which adapter card instance this table entry belongs.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cpqSsBoxBusIndex 1.3.6.1.4.1.232.8.2.1.1.2
Drive Box Bus Index. The bus index indicates to which bus instance on an adapter card this table entry belongs.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..255  

cpqSsBoxType 1.3.6.1.4.1.232.8.2.1.1.3
Drive Box Type. This is the type of drive box. The following types are defined: other(1) The agent does not recognize this drive storage system. proLiant(2) This is a ProLiant Storage System. proLiant2(3) This is a ProLiant-2 Storage System. proLiant2Internal(4) This is an internal ProLiant-2 Storage System that is found in some servers. proLiant2DuplexTop(5) This is the top portion of a ProLiant-2 Storage System that has dual SCSI busses which are duplexed. proLiant2DuplexBottom(6) This is the bottom portion of a ProLiant-2 Storage System that has dual SCSI busses which are duplexed. proLiant2InternalDuplexTop(7) This is the top portion of a ProLiant Server into which the internal SCSI busses are duplexed. proLiant2InternalDuplexBottom(8) This is the bottom portion of a ProLiant Server into which the internal SCSI busses are duplexed.
Status: deprecated Access: read-only
OBJECT-TYPE    
  INTEGER other(1), proLiant(2), proLiant2(3), proLiant2Internal(4), proLiant2DuplexTop(5), proLiant2DuplexBottom(6), proLiant2InternalDuplexTop(7), proLiant2InternalDuplexBottom(8)  

cpqSsBoxModel 1.3.6.1.4.1.232.8.2.1.1.4
Drive Box Model. This is a description of the drive box's model. This can be used for identification purposes.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..17)  

cpqSsBoxFWRev 1.3.6.1.4.1.232.8.2.1.1.5
Drive Box Firmware Revision. This is the revision level of the drive box. This can be used for identification purposes.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..8)  

cpqSsBoxVendor 1.3.6.1.4.1.232.8.2.1.1.6
Drive Box Vendor This is the drive box's vendor name. This can be used for identification purposes.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..9)  

cpqSsBoxFanStatus 1.3.6.1.4.1.232.8.2.1.1.7
Drive Box Fan Status. This is the current status of the fans in the drive box. This value will be one of the following: other(1) Fan monitoring is not supported by this system or it is not supported by the driver. ok(2) All fans are working normally. failed(3) One or more storage system fans have failed. The fan(s) should be replaced immediately to avoid hardware damage. noFan(4) This unit does not support fan monitoring. degraded(5) At least one storage system fan has failed, but there is still sufficient cooling capacity to allow the system to continue. The fan should be replaced.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(1), ok(2), failed(3), noFan(4), degraded(5)  

cpqSsBoxCondition 1.3.6.1.4.1.232.8.2.1.1.8
SCSI Drive Box Condition. This is the overall condition of the drive box. The following values are defined: other(1) The agent does not recognize the status. You may need to upgrade your software. ok(2) The storage system is operating normally. No user action is required. degraded(3) The storage system is degraded. You need to check the temperature status or power supply status of this storage system. Additionally, if the side panel for the storage system is removed, the air flow changes could result in improper cooling of the drives and affect the temperature status. failed(4) The storage system has failed.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(1), ok(2), degraded(3), failed(4)  

cpqSsBoxTempStatus 1.3.6.1.4.1.232.8.2.1.1.9
The temperature of the drive system. This value will be one of the following: other(1) Temperature monitoring is not supported by this system or it is not supported by the driver. ok(2) The temperature is within normal operating range. degraded(3) The temperature is outside of normal operating range. failed(4) The temperature could permanently damage the system. The storage system will automatically shutdown if this condition is detected. noTemp(5) This unit does not support temperature monitoring.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(1), ok(2), degraded(3), failed(4), noTemp(5)  

cpqSsBoxSidePanelStatus 1.3.6.1.4.1.232.8.2.1.1.10
Drive Box Side Panel Status. This value will be one of the following: other(1) The agent does not recognize the status. You may need to upgrade your software. sidePanelInPlace(2) The side panel is properly installed on the storage system. sidePanelRemoved(3) The side panel is not properly installed on the storage system. noSidePanelStatus(4) This unit does not support side panel status monitoring.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(1), sidePanelInPlace(2), sidePanelRemoved(3), noSidePanelStatus(4)  

cpqSsBoxFltTolPwrSupplyStatus 1.3.6.1.4.1.232.8.2.1.1.11
This value specifies the overall status of the fault tolerant power supply sub-system in a drive box. This value will be one of the following: other(1) The power supply status cannot be determined. ok(2) There are no detected power supply failures. degraded(3) One of the power supply units in a fault tolerant power supply has failed. failed(4) No failure conditions can currently be determined. noFltTolPower(5) This unit does not support fault tolerant power supply monitoring.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(1), ok(2), degraded(3), failed(4), noFltTolPower(5)  

cpqSsBoxBackPlaneVersion 1.3.6.1.4.1.232.8.2.1.1.12
Drive Box Back Plane Version. This is the version of the drive box back plane. The following types are defined: other(1) The agent does not recognize this drive storage system back plane. proLiant(2) This is a ProLiant Storage System. proLiant2(3) This is a ProLiant-2 Storage System. proLiant3(4) This is a ProLiant-3 Storage System. proLiant4(5) This is a 4th generation Proliant Storage System. proLiant5(6) This is a 5th generation ProLiant Storage System.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(1), proLiant(2), proLiant2(3), proLiant3(4), proLiant4(5), proLiant5(6)  

cpqSsBoxTotalBays 1.3.6.1.4.1.232.8.2.1.1.13
Drive Box Total Bays. This is the total number of bays in this storage system. If the value cannot be determined or does not apply, -1 is returned.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cpqSsBoxPlacement 1.3.6.1.4.1.232.8.2.1.1.14
Drive Box Placement. The following values are defined: other(1) The agent is unable to determine if this storage system is located internal or external to the system chassis. internal(2) The storage system is located in the system chassis. external(3) The storage system is located outside the system chassis in an expansion box.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(1), internal(2), external(3)  

cpqSsBoxDuplexOption 1.3.6.1.4.1.232.8.2.1.1.15
Drive Box Duplex Option. The following values are defined: other(1) The agent is unable to determine if this storage system is duplexed. notDuplexed(2) This storage system is not duplexed. duplexTop(3) This is the top portion of a duplexed storage system. duplexBottom(4) This is the bottom portion of a duplexed storage system.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(1), notDuplexed(2), duplexTop(3), duplexBottom(4)  

cpqSsBoxBoardRevision 1.3.6.1.4.1.232.8.2.1.1.16
Drive Box Board Revision. This is the board revision of this storage system backplane.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cpqSsBoxSerialNumber 1.3.6.1.4.1.232.8.2.1.1.17
Drive Box Serial Number. This is the drive box's serial number which is normally display on the front panel. This can be used for identification purposes. If the box's serial number cannot be determined, the agent will return a NULL string.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..24)  

cpqSsBoxCntlrHwLocation 1.3.6.1.4.1.232.8.2.1.1.18
A text description of the hardware location of the controller to which this box is attached. A NULL string indicates that the hardware location could not be determined or is irrelevant.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

cpqSsBoxBackplaneSpeed 1.3.6.1.4.1.232.8.2.1.1.19
Drive Box Backplane Speed. The following values are defined: other(1) The agent is unable to determine the backplane speed for this storage system. ultra3(2) This storage system is capable of Ultra3 speeds. ultra320(3) This storage system is capable of Ultra320 speeds.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(1), ultra3(2), ultra320(3)  

cpqSsBoxConnectionType 1.3.6.1.4.1.232.8.2.1.1.20
Drive Box Connection Type. The following values are defined: other(1) The agent is unable to determine the type of connection to this storage system. scsiAttached(2) This storage system is attached to the host via SCSI. sasAttached(3) This storage system is attached to the host via SAS.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(1), scsiAttached(2), sasAttached(3)  

cpqSsBoxHostConnector 1.3.6.1.4.1.232.8.2.1.1.21
Drive Box Host Connector. This is the host connector to which the drive box is attached. If the host connector cannot be determined, the agent will return a NULL string.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..4)  

cpqSsBoxBoxOnConnector 1.3.6.1.4.1.232.8.2.1.1.22
Drive Box, Box on Connector. The box on connector indicates which box instance this table entry belongs. The instances start at one and increment for each box attached to a connector. If the value cannot be determined or does not apply, -1 is returned.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cpqSsBoxLocationString 1.3.6.1.4.1.232.8.2.1.1.23
Drive Box Location String. This string describes the location of the drive box in relation to the controller to which it is attached. If the location string cannot be determined, the agent will return a NULL string.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

cpqSsBoxInitiatorSasAddress 1.3.6.1.4.1.232.8.2.1.1.24
Drive Box Initiator SAS Address String. This string describes the SAS address of the initiator connected to the drive box. If the drive box initiator SAS address string cannot be determined, the agent will return a NULL string.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..16)  

cpqSsBoxTargetSasAddress 1.3.6.1.4.1.232.8.2.1.1.25
Drive Box Target SAS Address String. This string describes the SAS address of the target (i.e. the drive box itself). If the drive box target SAS address string cannot be determined, the agent will return a NULL string.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..16)  

cpqSsBoxLocalManageIpAddress 1.3.6.1.4.1.232.8.2.1.1.26
Drive Box Local Management IP Address String. This string reports the management IP address for the storage box primary controller. If the drive box local management IP address string cannot be determined, the agent will return a NULL string.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..64)  

cpqSsBoxPartnerManageIpAddress 1.3.6.1.4.1.232.8.2.1.1.27
Drive Box Partner Management IP Address String. This string reports the management IP address for the storage box partner controller. If the drive box partner management IP address string cannot be determined, the agent will return a NULL string.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..64)  

cpqSsBoxConnectionStatus 1.3.6.1.4.1.232.8.2.1.1.28
Drive Box Connection Status. The following values are defined: other(1) The agent is unable to determine the storage system's connection status. notSupported(2) Reporting this storage system's connection status is not supported. connected(3) The storage system is connected. notConnected(4) The storage system is disconnected.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(1), notSupported(2), connected(3), notConnected(4)  

cpqSsBoxTargetBasedManagement 1.3.6.1.4.1.232.8.2.1.1.29
Drive Box Target Based Management. The following values are defined: other(1) The agent is unable to determine if this storage system supports target based management. tbmNotSupported(2) The storage system does not support target based management. tbmSupported(3) The storage system supports target based management.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(1), tbmNotSupported(2), tbmSupported(3)  

cpqSsChassisTable 1.3.6.1.4.1.232.8.2.2.1
Storage System Chassis Table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    CpqSsChassisEntry

cpqSsChassisEntry 1.3.6.1.4.1.232.8.2.2.1.1
Storage System Chassis Entry.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  CpqSsChassisEntry  

cpqSsChassisIndex 1.3.6.1.4.1.232.8.2.2.1.1.1
Storage System Chassis Index. The chassis index uniquely identifies a storage system chassis.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..65535  

cpqSsChassisConnectionType 1.3.6.1.4.1.232.8.2.2.1.1.2
Storage System Chassis Connection Type. The following values are defined: other(1) The agent is unable to determine the type of connection to this chassis. fibreAttached(2) This chassis is attached to the server via Fibre Channel. scsiAttached(3) This chassis is attached to the server via SCSI. iScsiAttached(4) This chassis is attached to the server via iSCSI. sasAttached(5) This chassis is attached to the server via SAS.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(1), fibreAttached(2), scsiAttached(3), iScsiAttached(4), sasAttached(5)  

cpqSsChassisSerialNumber 1.3.6.1.4.1.232.8.2.2.1.1.3
Storage System Chassis Serial Number. This is the storage system chassis's serial number which is normally displayed on the front panel. This can be used for identification purposes.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..32)  

cpqSsChassisName 1.3.6.1.4.1.232.8.2.2.1.1.4
Storage System Chassis Name. This is a user defined name for this storage system chassis.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..32)  

cpqSsChassisSystemBoardSerNum 1.3.6.1.4.1.232.8.2.2.1.1.5
Storage System Chassis System Controller Board Serial Number. This is the system controller board's serial number. This can be used for identification purposes.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..24)  

cpqSsChassisSystemBoardRev 1.3.6.1.4.1.232.8.2.2.1.1.6
Storage System Chassis System Controller Board Revision. This is the system controller board revision.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..8)  

cpqSsChassisPowerBoardSerNum 1.3.6.1.4.1.232.8.2.2.1.1.7
Storage System Chassis Power Backplane Board Serial Number. This is the power backplane board's serial number. This can be used for identification purposes.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..24)  

cpqSsChassisPowerBoardRev 1.3.6.1.4.1.232.8.2.2.1.1.8
Storage System Chassis Power Backplane Board Revision. This is the power backplane board revision.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..8)  

cpqSsChassisScsiBoardSerNum 1.3.6.1.4.1.232.8.2.2.1.1.9
Storage System Chassis SCSI Drive Backplane Board Serial Number. This is the SCSI drive backplane board's serial number. This can be used for identification purposes.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..24)  

cpqSsChassisScsiBoardRev 1.3.6.1.4.1.232.8.2.2.1.1.10
Storage System Chassis SCSI Drive Backplane Board Revision. This is the SCSI drive backplane board revision.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..8)  

cpqSsChassisOverallCondition 1.3.6.1.4.1.232.8.2.2.1.1.11
Storage System Chassis Overall Condition. This is the condition of the storage system chassis and all of its components. The following values are defined: other(1) The agent does not recognize the status. You may need to upgrade your software. ok(2) The storage system is operating normally. No user action is required. degraded(3) The storage system chassis is degraded. failed(4) The storage system chassis is failed.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(1), ok(2), degraded(3), failed(4)  

cpqSsChassisPowerSupplyCondition 1.3.6.1.4.1.232.8.2.2.1.1.12
Storage System Power Supply Condition. This is the aggregate condition of all power supplies in the storage system chassis. The following values are defined: other(1) The agent does not recognize the status. You may need to upgrade your software. ok(2) All power supplies are operating normally. degraded(3) At least one power supply is degraded or failed. failed(4) All power supplies are failed.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(1), ok(2), degraded(3), failed(4)  

cpqSsChassisFanCondition 1.3.6.1.4.1.232.8.2.2.1.1.13
Storage System Fan Condition. This is the aggregate condition of all fan modules in the storage system chassis. The following values are defined: other(1) The agent does not recognize the status. You may need to upgrade your software. ok(2) All fan modules are operating normally. degraded(3) At least one fan module is degraded. failed(4) At least one fan module is failed.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(1), ok(2), degraded(3), failed(4)  

cpqSsChassisTemperatureCondition 1.3.6.1.4.1.232.8.2.2.1.1.14
Storage System Temperature Condition. This is the aggregate condition of all the temperatur sensors in the storage system chassis. The following values are defined: other(1) The agent does not recognize the status. You may need to upgrade your software. ok(2) All temperature sensors are reading within normal limits. degraded(3) At least one temperature sensor is reading degraded. failed(4) At least one temperature sensor is reading failed.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(1), ok(2), degraded(3), failed(4)  

cpqSsChassisFcaCntlrCondition 1.3.6.1.4.1.232.8.2.2.1.1.15
Storage System Fibre Channel Array Controller Condition. This is the aggregate condition of all Fibre Channel Array controllers in the storage system chassis. The following values are defined: other(1) The condition cannot be determined or is not supported on this storage system. ok(2) All Fibre Channel Array Controllers are operating normally. degraded(3) At least one Fibre Channel Array Controller is degraded or failed. failed(4) All Fibre Channel Array Controllers are failed.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(1), ok(2), degraded(3), failed(4)  

cpqSsChassisFcaLogicalDriveCondition 1.3.6.1.4.1.232.8.2.2.1.1.16
Storage System Fibre Channel Array Logical Drive Condition. This is the aggregate condition of all Fibre Channel Array Logical Drives in this storage system chassis. The following values are defined: other(1) The condition cannot be determined or is not supported on this storage system. ok(2) All Fibre Channel Array Controllers Logical Drives are operating normally. degraded(3) At least one Fibre Channel Array Controller Logical Drive is degraded. failed(4) At least one Fibre Channel Array Controller Logical Drive is failed.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(1), ok(2), degraded(3), failed(4)  

cpqSsChassisFcaPhysDrvCondition 1.3.6.1.4.1.232.8.2.2.1.1.17
Storage System Fibre Channel Array Physical Drive Condition. This is the aggregate condition of all Fibre Channel Array Physical Drives in this storage system chassis. The following values are defined: other(1) The condition cannot be determined or is not supported on this storage system. ok(2) All Fibre Channel Array Controllers Physical Drives are operating normally. degraded(3) At least one Fibre Channel Array Controller Physical Drive is degraded. failed(4) At least one Fibre Channel Array Controller Physical Drive is failed.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(1), ok(2), degraded(3), failed(4)  

cpqSsChassisTime 1.3.6.1.4.1.232.8.2.2.1.1.18
Storage System Chassis Time. This is the storage system chassis's time in tenths of seconds. If the chassis time is not supported, the agent will return 0.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cpqSsChassisModel 1.3.6.1.4.1.232.8.2.2.1.1.19
Storage System Chassis Model. The following values are defined: other(1) The agent is unable to determine the model of this chassis. ra4x00(2) Compaq StorageWorks RAID Array 4000/4100. msa1000(3) Compaq StorageWorks Modular Smart Array 1000. smartArrayClusterStorage(4) HP StorageWorks Modular Smart Array 500 (Formerly Smart Array Cluster Storage). enterpriseModularArray(5) Compaq StorageWorks Enterprise/Modular RAID Array. enterpriseVirtualArray(6) Compaq StorageWorks Enterprise Virtual Array. msa500G2(7) HP StorageWorks Modular Smart Array 500 G2. msa20(8) HP StorageWorks Modular Smart Array 20. msa1500cs(9) HP StorageWorks Modular Smart Array 1500 CS. msa1510i(10) HP StorageWorks Modular Smart Array 1510i. Reserved(11) Reserved(12)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(1), ra4x00(2), msa1000(3), smartArrayClusterStorage(4), enterpriseModularArray(5), enterpriseVirtualArray(6), msa500G2(7), msa20(8), msa1500cs(9), msa1510i(10)  

cpqSsChassisBackplaneCondition 1.3.6.1.4.1.232.8.2.2.1.1.20
Storage System Backplane Condition. This is the aggregate condition of all the backplanes for the storage system chassis. The following values are defined: other(1) The agent does not recognize the status. You may need to upgrade your software. ok(2) All backplanes are operating normally. degraded(3) At least one storage system is degraded. failed(4) At least one storage system is failed.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(1), ok(2), degraded(3), failed(4)  

cpqSsChassisFcaTapeDrvCondition 1.3.6.1.4.1.232.8.2.2.1.1.21
Storage System Array Tape Drive Condition. This is the aggregate condition of all tape drives in this storage system chassis. The following values are defined: other(1) The condition cannot be determined or is not supported on this storage system. ok(2) All tape drives are operating normally. degraded(3) At least one tape drive is degraded. failed(4) At least one tape drive is failed.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(1), ok(2), degraded(3), failed(4)  

cpqSsChassisRsoStatus 1.3.6.1.4.1.232.8.2.2.1.1.22
Storage System Chassis Recovery Server Option Status. The following values are defined: other(1) The recovery server option status cannot be determined for this storage system. notSupported(2) The recovery server option is not supported for this storage system. notConfigured(3) The recovery server option is supported, but is not configured on this storage system. disabled(4) The recovery server option is configured as primary, but has been disabled by software. daemonDownDisabled(5) The recovery server option operating system daemon is no longer running. The last status of RSO was disabled(4). ok(6) The recovery server option is configured as primary and everything is working correctly. daemonDownActive(7) The recovery server option operating system daemon is no longer running. The last status of RSO was ok(6). noSecondary(8) The recovery server option is configured as primary, but communication with the standby server has not been established. daemonDownNoSecondary(9) The recovery server option operating system daemon is no longer running. The last status of RSO was noSecondary(8). linkDown(10) The recovery server option is configured as primary, but communication with the standby server has failed. daemonDownLinkDown(11) The recovery server option operating system daemon is no longer running. The last status of RSO was linkDown(10). secondaryRunningAuto(12) The recovery server option is configured and the standby server is running. The secondary server assumed control after communication with the primary server failed. secondaryRunningUser(13) The recovery server option is configured and the standby server is running. A user forced the secondary server to assume control. evTimeoutError(14) The recovery server option environment variable cannot be accessed.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(1), notSupported(2), notConfigured(3), disabled(4), daemonDownDisabled(5), ok(6), daemonDownActive(7), noSecondary(8), daemonDownNoSecondary(9), linkDown(10), daemonDownLinkDown(11), secondaryRunningAuto(12), secondaryRunningUser(13), evTimeoutError(14)  

cpqSsChassisRsoCondition 1.3.6.1.4.1.232.8.2.2.1.1.23
Storage System Chassis Recovery Server Option Condition. This is the condition of the recovery server option. The following values are defined: other(1) The agent does not recognize the status. You may need to upgrade your software. ok(2) The recovery server option is operating normally. No user action is required. degraded(3) The recovery server option is degraded. failed(4) The recovery server option is failed.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(1), ok(2), degraded(3), failed(4)  

cpqSsChassisScsiIoModuleType 1.3.6.1.4.1.232.8.2.2.1.1.24
Storage System Chassis SCSI I/O Module Type. The following values are defined: other(1) The agent does not recognize SCSI I/O module type. You may need to upgrade your software. io2port(2) A 2-Port Ultra3 SCSI I/O Module is installed. io4portUpgradeFirmware(3) A 4-Port Shared Storage Module for Smart Array Cluster Storage is installed, but the current controller firmware does not support it. Upgrade your controller firmware. io4port(4) A 4-Port Shared Storage Module for Smart Array Cluster Storage is installed. io2port320(5) A 2-Port Ultra320 SCSI I/O Module is installed. io4port320(6) A 4-Port Ultra320 SCSI I/O Module is installed. io1port320(7) A 1-Port Ultra320 SCSI I/O Module is installed.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(1), io2port(2), io4portUpgradeFirmware(3), io4port(4), io2port320(5), io4port320(6), io1port320(7)  

cpqSsChassisPreferredPathMode 1.3.6.1.4.1.232.8.2.2.1.1.25
Array Controller Preferred Path Mode. This is the storage system active/active preferred path mode. The following values are valid: other (1) Indicates that the agent does not recognize the preferred path mode of the storage system. You may need to upgrade the agent. notActiveActive (2) The storage system is not configured as active/active. automatic (3) The storage system automatically selects the preferred path for each logical drive based on host I/O patterns. manual (4) The preferred path for each logical drive is manually configured by the storage system administrator.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(1), notActiveActive(2), automatic(3), manual(4)  

cpqSsChassisProductId 1.3.6.1.4.1.232.8.2.2.1.1.26
Storage System Chassis Product Identifier. This is the storage system chassis's product identifier. This can be used for identification purposes. If the product identifier can not be determined, the agent will return a NULL string.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..32)  

cpqSsIoSlotTable 1.3.6.1.4.1.232.8.2.2.2
Storage System I/O Slot Table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    CpqSsIoSlotEntry

cpqSsIoSlotEntry 1.3.6.1.4.1.232.8.2.2.2.1
Storage System I/O Slot Entry.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  CpqSsIoSlotEntry  

cpqSsIoSlotChassisIndex 1.3.6.1.4.1.232.8.2.2.2.1.1
Storage System I/O Slot Chassis Index. The chassis index uniquely identifies a storage system chassis.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..65535  

cpqSsIoSlotIndex 1.3.6.1.4.1.232.8.2.2.2.1.2
Storage System I/O Slot Index. This index uniquely identifies a storage system I/O Slot.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cpqSsIoSlotControllerType 1.3.6.1.4.1.232.8.2.2.2.1.3
Storage System I/O Slot Controller Type. The following values are defined: other(1) The agent is unable to determine if anything is installed in this storage system I/O slot. notInstalled(2) Nothing is installed in this storage system I/O slot. unknownBoardInstalled(3) An unknown controller is installed in this storage system I/O slot. fibreArray(4) A Fibre Channel Array controller is installed in this storage system I/O slot. scsiArray(5) A SCSI Array controller is installed in this storage system I/O slot. noSlot(6) The slot does not exist on this chassis. iScsiArray(7) An iSCSI Array controller is installed in this storage system I/O slot. sasArray(8) A SAS Array controller is installed in this storage system I/O slot.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(1), notInstalled(2), unknownBoard(3), fibreArray(4), scsiArray(5), noSlot(6), iScsiArray(7), sasArray(8)  

cpqSsPowerSupplyTable 1.3.6.1.4.1.232.8.2.2.3
Storage System Power Supply Table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    CpqSsPowerSupplyEntry

cpqSsPowerSupplyEntry 1.3.6.1.4.1.232.8.2.2.3.1
Storage System Power Supply Entry.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  CpqSsPowerSupplyEntry  

cpqSsPowerSupplyChassisIndex 1.3.6.1.4.1.232.8.2.2.3.1.1
Storage System Power Supply Chassis Index. The chassis index uniquely identifies a storage system chassis.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..65535  

cpqSsPowerSupplyIndex 1.3.6.1.4.1.232.8.2.2.3.1.2
Storage System Power Supply Bay. This index uniquely identifies a power supply bay.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cpqSsPowerSupplyBay 1.3.6.1.4.1.232.8.2.2.3.1.3
Storage System Power Supply Bay. The following values are defined: other(1) The agent does not recognize the bay. You may need to upgrade your software. powerBay1(2) The power supply is installed in the first power supply bay. powerBay2(3) The power supply is installed in the second power supply bay. composite(4) The power supply information is a composite of all power supplies in the storage system.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(1), powerBay1(2), powerBay2(3), composite(4)  

cpqSsPowerSupplyStatus 1.3.6.1.4.1.232.8.2.2.3.1.4
Storage System Power Supply Status. The following values are defined: other(1) The agent is unable to determine if this storage system power supply bay is occupied. notInstalled(2) Nothing is installed in this power supply bay. ok(3) A power supply is installed and operating normally. failed(4) A power supply is installed and is no longer operating. Replace the power supply. degraded(5) For composite power supplies, this indicates that at least one power supply has failed or lost power.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(1), notInstalled(2), ok(3), failed(4), degraded(5)  

cpqSsPowerSupplyUpsStatus 1.3.6.1.4.1.232.8.2.2.3.1.5
Storage System Power Supply Uninterruptible Power Supply (UPS) Status. The following values are defined: other(1) The agent is unable to determine if this power supply is attached to an Uninterruptible Power Supply (UPS). noUps(2) No UPS is attached to the power supply. ok(3) A UPS is attached to the power supply and is operating normally. powerFailed(4) A UPS is attached to the power supply and the AC power has failed. batteryLow(5) A UPS is attached to the power supply, the AC power has failed and the UPS battery is low.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(1), noUps(2), ok(3), powerFailed(4), batteryLow(5)  

cpqSsPowerSupplyCondition 1.3.6.1.4.1.232.8.2.2.3.1.6
Storage System Power Supply Condition. This is the condition of the storage system chassis and all of its components. The following values are defined: other(1) The agent does not recognize the status. You may need to upgrade your software. ok(2) The power supply is operating normally. No user action is required. degraded(3) The power supply is degraded. You need to check the power supply or its attached UPS for problems. failed(4) The power supply has failed.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(1), ok(2), degraded(3), failed(4)  

cpqSsPowerSupplySerialNumber 1.3.6.1.4.1.232.8.2.2.3.1.7
Storage System Power Supply Serial Number. This is the power supply's serial number. This can be used for identification purposes. If the serial number is not supported, the agent will return a NULL string.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..24)  

cpqSsPowerSupplyBoardRevision 1.3.6.1.4.1.232.8.2.2.3.1.8
Storage System Power Supply Board Revision. This is the power supply board revision. If the board revision is not supported, the agent will return a NULL string.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..8)  

cpqSsPowerSupplyFirmwareRevision 1.3.6.1.4.1.232.8.2.2.3.1.9
Storage System Power Supply Firmware Revision. This is the power supply firmware revision. If the firmware revision is not supported, the agent will return a NULL string.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..8)  

cpqSsFanModuleTable 1.3.6.1.4.1.232.8.2.2.4
Storage System Fan Module Table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    CpqSsFanModuleEntry

cpqSsFanModuleEntry 1.3.6.1.4.1.232.8.2.2.4.1
Storage System Fan Module Entry.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  CpqSsFanModuleEntry  

cpqSsFanModuleChassisIndex 1.3.6.1.4.1.232.8.2.2.4.1.1
Storage System Fan Module Chassis Index. The chassis index uniquely identifies a storage system chassis.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..65535  

cpqSsFanModuleIndex 1.3.6.1.4.1.232.8.2.2.4.1.2
Storage System Fan Module Index. This index uniquely identifies a storage system fan module.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cpqSsFanModuleStatus 1.3.6.1.4.1.232.8.2.2.4.1.3
Storage System Fan Module Status. The following values are defined: other(1) The agent is unable to determine if this storage system fan module is installed. notInstalled(3) The fan module is not installed. ok(2) The fan module is installed and operating normally. degraded(4) The fan module degraded. failed(5) The fan module is failed. Replace the fan module.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(1), notInstalled(2), ok(3), degraded(4), failed(5)  

cpqSsFanModuleCondition 1.3.6.1.4.1.232.8.2.2.4.1.4
Storage System Fan Module Condition. This is the condition of the storage system fan module. The following values are defined: other(1) The agent does not recognize the status. You may need to upgrade your software. ok(2) The fan module is operating normally. No user action is required. degraded(3) The fan module is degraded. You need to check the fan module for problems. failed(4) The fan module has failed. Replace the fan module.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(1), ok(2), degraded(3), failed(4)  

cpqSsFanModuleLocation 1.3.6.1.4.1.232.8.2.2.4.1.5
Storage System Fan Module Location. The following values are defined: other(1) The agent is unable to determine the location of this storage system fan module. fanBay(2) This fan module is installed in the first fan bay. composite(3) The fan information is a composite of all fans in the storage system. fanBay2(4) This fan module is installed in the second fan bay.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(1), fanBay(2), composite(3), fanBay2(4)  

cpqSsFanModuleSerialNumber 1.3.6.1.4.1.232.8.2.2.4.1.6
Storage System Fan Module Serial Number. This is the fan module's serial number. This can be used for identification purposes.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..24)  

cpqSsFanModuleBoardRevision 1.3.6.1.4.1.232.8.2.2.4.1.7
Storage System Fan Module Board Revision. This is the fan module board revision.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..8)  

cpqSsTempSensorTable 1.3.6.1.4.1.232.8.2.2.5
Storage System Temperature Sensor Table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    CpqSsTempSensorEntry

cpqSsTempSensorEntry 1.3.6.1.4.1.232.8.2.2.5.1
Storage System Temperature Sensor Entry.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  CpqSsTempSensorEntry  

cpqSsTempSensorChassisIndex 1.3.6.1.4.1.232.8.2.2.5.1.1
Storage System Temperature Sensor Chassis Index. The chassis index uniquely identifies a storage system chassis.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..65535  

cpqSsTempSensorIndex 1.3.6.1.4.1.232.8.2.2.5.1.2
Storage System Temperature Sensor Index. This index uniquely identifies a temperature sensor.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cpqSsTempSensorStatus 1.3.6.1.4.1.232.8.2.2.5.1.3
Storage System Temperature Sensor Status. The following values are defined: other(1) The agent is unable to determine if the storage system temperature sensor status. ok(2) The temperature is OK. degraded(3) The temperature is degraded. failed(4) The temperature is failed.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(1), ok(2), degraded(3), failed(4)  

cpqSsTempSensorCondition 1.3.6.1.4.1.232.8.2.2.5.1.4
Storage System Fan Module Condition. This is the condition of the storage system temperature sensor. The following values are defined: other(1) The agent does not recognize the status. You may need to upgrade your software. ok(2) The temperature is within normal operating range. No user action is required. degraded(3) The temperature is outside of normal operating range. failed(4) The temperature could permanently damage the system. The storage system will automatically shutdown if this condition is detected.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(1), ok(2), degraded(3), failed(4)  

cpqSsTempSensorLocation 1.3.6.1.4.1.232.8.2.2.5.1.5
Storage System Fan Module Location. The following values are defined: other(1) The agent is unable to determine the location of this storage system temperature sensor. fanBay(2) This temperature sensor is located on the fan module in the fan bay. backplane(3) This temperature is located on the SCSI drive backplane.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(1), fanBay(2), backplane(3)  

cpqSsTempSensorCurrentValue 1.3.6.1.4.1.232.8.2.2.5.1.6
Storage System Temperature Sensor Current Value. The current value of the temperature sensor in degrees Celsius.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cpqSsTempSensorLimitValue 1.3.6.1.4.1.232.8.2.2.5.1.7
Storage System Temperature Sensor Limit Value. The limit value of the temperature sensor in degrees Celsius.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cpqSsTempSensorHysteresisValue 1.3.6.1.4.1.232.8.2.2.5.1.8
Storage System Temperature Sensor Hysteresis Value. The hysteresis value of the temperature sensor in degrees Celsius.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cpqSsBackplaneTable 1.3.6.1.4.1.232.8.2.2.6
Storage System SCSI Backplane Table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    CpqSsBackplaneEntry

cpqSsBackplaneEntry 1.3.6.1.4.1.232.8.2.2.6.1
Storage System SCSI Backplane Entry.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  CpqSsBackplaneEntry  

cpqSsBackplaneChassisIndex 1.3.6.1.4.1.232.8.2.2.6.1.1
Storage System Backplane Chassis Index. The chassis index uniquely identifies a storage system chassis.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..65535  

cpqSsBackplaneIndex 1.3.6.1.4.1.232.8.2.2.6.1.2
Storage System Backplane Index. This index uniquely identifies a storage system backplane.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..255  

cpqSsBackplaneFWRev 1.3.6.1.4.1.232.8.2.2.6.1.3
Storage System Backplane Firmware Revision. This is the revision level of storage system backplane.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..8)  

cpqSsBackplaneDriveBays 1.3.6.1.4.1.232.8.2.2.6.1.4
Storage System Backplane Drive Bays. This is the number of bays on this storage system backplane.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..255  

cpqSsBackplaneDuplexOption 1.3.6.1.4.1.232.8.2.2.6.1.5
Storage System Backplane Duplex Option. The following values are defined: other (1) The agent is unable to determine if this storage system is duplexed. notDuplexed(2) This storage system is not duplexed. duplexTop(3) This is the top portion of a duplexed storage system. duplexBottom(4) This is the bottom portion of a duplexed storage system.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(1), notDuplexed(2), duplexTop(3), duplexBottom(4)  

cpqSsBackplaneCondition 1.3.6.1.4.1.232.8.2.2.6.1.6
Storage System Backplane Condition. This is the overall condition of the backplane. The following values are defined: other(1) The agent does not recognize the status. You may need to upgrade your software. ok(2) The storage system is operating normally. No user action is required. degraded(3) The storage system is degraded. You need to check the temperature status or power supply status of this storage system. failed(4) The storage system has failed.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(1), ok(2), degraded(3), failed(4)  

cpqSsBackplaneVersion 1.3.6.1.4.1.232.8.2.2.6.1.7
Storage System Backplane Version. This is the version of the drive box back plane.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cpqSsBackplaneVendor 1.3.6.1.4.1.232.8.2.2.6.1.8
Storage System Backplane Vendor This is the storage box's vendor name. This can be used for identification purposes.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..9)  

cpqSsBackplaneModel 1.3.6.1.4.1.232.8.2.2.6.1.9
Storage System Backplane Model. This is a description of the storage system's model. This can be used for identification purposes.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..17)  

cpqSsBackplaneFanStatus 1.3.6.1.4.1.232.8.2.2.6.1.10
Storage System Backplane Fan Status. This is the current status of the fans in the storage system. This value will be one of the following: other(1) The agent is unable to determine if this storage system has fan monitoring. notInstalled(2) This unit does not support fan monitoring. ok(3) All fans are working normally. degraded(4) At least one storage system fan has failed, but there is still sufficient cooling capacity to allow the system to continue. The fan should be replaced. failed(5) One or more storage system fans have failed. The fan(s) should be replaced immediately to avoid hardware damage. notSupported(6) The storage system does not support reporting fan status through this backplane. The fan status is reported through the first backplane on this storage system. degraded-Fan1Failed(7) Fan 1 has failed, but there is still sufficient cooling capacity to allow the system to continue. The fan should be replaced. degraded-Fan2Failed(8) Fan 2 has failed, but there is still sufficient cooling capacity to allow the system to continue. The fan should be replaced.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(1), notInstalled(2), ok(3), degraded(4), failed(5), notSupported(6), degraded-Fan1Failed(7), degraded-Fan2Failed(8)  

cpqSsBackplaneTempStatus 1.3.6.1.4.1.232.8.2.2.6.1.11
Storage System Backplane Fan Status. This value will be one of the following: other(1) The agent is unable to determine if this storage system has temperature monitoring. noTemp(2) This unit does not support temperature monitoring. ok(3) The temperature is within normal operating range. degraded(4) The temperature is outside of normal operating range. failed(5) The temperature could permanently damage the system. notSupported(6) The storage system does not support reporting temperature status through this backplane. The temperature status is reported through the first backplane on this storage system.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(1), noTemp(2), ok(3), degraded(4), failed(5), notSupported(6)  

cpqSsBackplaneFtpsStatus 1.3.6.1.4.1.232.8.2.2.6.1.12
Storage System Backplane Fault Tolerant Power Supply Status. This value specifies the overall status of the redundant power supply in a drive box. This value will be one of the following: other(1) The agent is unable to determine if this storage system has redundant power supplies. noFltTolPower(2) This unit does not have a redundant supply. ok(3) There are no detected power supply failures. degraded(4) One of the power supply units has failed. failed(5) All of the power supplies have failed. A status of failed can not currently be determined. notSupported(6) The storage system does not support reporting fault tolerant power supply status through this backplane. The fault tolerant power supply status is reported through the first backplane on this storage system. noFltTolPower-Bay1Missing(7), This unit does not have a redundant supply. The power supply in bay 1 is missing. noFltTolPower-Bay2Missing(8) This unit does not have a redundant supply. The power supply in bay 2 is missing.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(1), noFltTolPower(2), ok(3), degraded(4), failed(5), notSupported(6), noFltTolPower-Bay1Missing(7), noFltTolPower-Bay2Missing(8)  

cpqSsBackplaneSerialNumber 1.3.6.1.4.1.232.8.2.2.6.1.13
Storage System Backplane Serial Number. This is the storage system backplane serial number which is normally displayed on the front bezel. This can be used for identification purposes.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..24)  

cpqSsBackplanePlacement 1.3.6.1.4.1.232.8.2.2.6.1.14
Storage System Backplane Placement. The following values are defined: other(1) The agent is unable to determine if this storage system is located internal or external to the system chassis. internal(2) The storage system is located in the system chassis. external(3) The storage system is located outside the system chassis in an expansion box.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(1), internal(2), external(3)  

cpqSsBackplaneBoardRevision 1.3.6.1.4.1.232.8.2.2.6.1.15
Storage System Backplane Board Revision. This is the board revision of this storage system backplane.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cpqSsBackplaneSpeed 1.3.6.1.4.1.232.8.2.2.6.1.16
Storage System Backplane Speed. The following values are defined: other(1) The agent is unable to determine the backplane speed for this storage system. ultra3(2) This storage system is capable of Ultra3 speeds. ultra320(3) This storage system is capable of Ultra320 speeds. sata(4) This storage system is capable of SATA speeds.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(1), ultra3(2), ultra320(3), sata(4)  

cpqSsBackplaneConnectionType 1.3.6.1.4.1.232.8.2.2.6.1.17
Backlane Box Connection Type. The following values are defined: other(1) The agent is unable to determine the type of connection to this backplane. scsiAttached(2) This backplane is attached to the host via SCSI. sasAttached(3) This backplane is attached to the host via SAS.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(1), scsiAttached(2), sasAttached(3)  

cpqSsBackplaneConnector 1.3.6.1.4.1.232.8.2.2.6.1.18
Backplane Connector. This is the connector to which the backplane is attached. If the backplane connector cannot be determined, the agent will return a NULL string.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..4)  

cpqSsBackplaneOnConnector 1.3.6.1.4.1.232.8.2.2.6.1.19
Backplane on Connector. The backplane on connector indicates to which backplane instance this table entry belongs. The instances start at one and increment for each backplane attached to a connector.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cpqSsBackplaneLocationString 1.3.6.1.4.1.232.8.2.2.6.1.20
Backplane Location String. This string describes the location of the backplane in relation to the controller to which it is attached. If the location string cannot be determined, the agent will return a NULL string.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

cpqSsFibreAttachmentTable 1.3.6.1.4.1.232.8.2.2.7
Storage System Fibre Attachment Table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    CpqSsFibreAttachmentEntry

cpqSsFibreAttachmentEntry 1.3.6.1.4.1.232.8.2.2.7.1
Storage System Fibre Attachment Entry.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  CpqSsFibreAttachmentEntry  

cpqSsFibreAttachmentIndex 1.3.6.1.4.1.232.8.2.2.7.1.1
Storage System Fibre Attachment Index. The index uniquely identifies a Fibre Attachment association entry.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cpqSsFibreAttachmentHostControllerIndex 1.3.6.1.4.1.232.8.2.2.7.1.2
Storage System Fibre Attachment Host Controller Index. The host controller index indicates which host controller is associated with this entry. This is equal to cpqFcaHostCntlrIndex, from the Fibre Channel Host Controller Table.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cpqSsFibreAttachmentHostControllerPort 1.3.6.1.4.1.232.8.2.2.7.1.3
Storage System Fibre Attachment Host Controller Port. This is the Fibre port number of the host controller. For each host controller, the port number starts at 1 and increments for each port. This is currently set to 1.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..255  

cpqSsFibreAttachmentDeviceType 1.3.6.1.4.1.232.8.2.2.7.1.4
Storage System Fibre Attachment Device Type. This is the type of device associated with this entry. The following values are defined: other(1) The agent is unable to determine if the type of this device. storageBox(2) The device is a Fibre attached storage system. tapeController(3) The device is a Fibre attached tape controller. fibreChannelSwitch(4) The device is a Fibre channel switch.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(1), storageBox(2), tapeController(3), fibreChannelSwitch(4)  

cpqSsFibreAttachmentDeviceIndex 1.3.6.1.4.1.232.8.2.2.7.1.5
Storage System Fibre Attachment Device Index. The is the index for the Fibre attached device. For a Fibre attached storage system, this is equal to cpqSsChassisIndex from the Storage System Chassis Table. For a Fibre attached tape controller, this is equal to cpqFcTapeCntlrIndex from the Fibre Channel Tape Controller Table. For a Fibre channel switch, this is equal to cpqFcSwitchIndex from the Fibre Channel Switch Table.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..65535  

cpqSsFibreAttachmentDevicePort 1.3.6.1.4.1.232.8.2.2.7.1.6
Storage System Fibre Attachment Device Port. This is the Fibre port on a device. For a Fibre attached storage system, this is equal to cpqFcaCntlrBoxIoSlot from the Fibre Channel Array Controller Table. For a Fibre attached tape controller, this is currently set to 1. For a Fibre channel switch, this is currently set to 1.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..255  

cpqSsScsiAttachmentTable 1.3.6.1.4.1.232.8.2.2.8
Storage System SCSI Attachment Table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    CpqSsScsiAttachmentEntry

cpqSsScsiAttachmentEntry 1.3.6.1.4.1.232.8.2.2.8.1
Storage System SCSI Attachment Entry.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  CpqSsScsiAttachmentEntry  

cpqSsScsiAttachmentIndex 1.3.6.1.4.1.232.8.2.2.8.1.1
Storage System SCSI Attachment Index. The index uniquely identifies a SCSI Attachment association entry.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cpqSsScsiAttachmentControllerIndex 1.3.6.1.4.1.232.8.2.2.8.1.2
Storage System SCSI Attachment Controller Index. The controller index indicates which internal array controller is associated with this entry. This is equal to cpqDaCntlrIndex, from the Array Controller Table.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..255  

cpqSsScsiAttachmentControllerPort 1.3.6.1.4.1.232.8.2.2.8.1.3
Storage System SCSI Attachment Controller Port. The controller port indicates which SCSI port of an internal controller is associated with this entry.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..255  

cpqSsScsiAttachmentControllerTarget 1.3.6.1.4.1.232.8.2.2.8.1.4
Storage System SCSI Attachment Controller Target. The controller target indicates which SCSI target is associated with this entry.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..255  

cpqSsScsiAttachmentControllerLun 1.3.6.1.4.1.232.8.2.2.8.1.5
Storage System SCSI Attachment Controller Lun. The controller Lun indicates which SCSI Lun is associated with this entry.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..255  

cpqSsScsiAttachmentChassisIndex 1.3.6.1.4.1.232.8.2.2.8.1.6
Storage System SCSI Attachment Chassis Index. The is the index for the SCSI attached storage system. This is equal to cpqSsChassisIndex from the Storage System Chassis Table.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..65535  

cpqSsScsiAttachmentChassisIoSlot 1.3.6.1.4.1.232.8.2.2.8.1.7
Storage System SCSI Attachment Chassis I/O Slot. This is the I/O slot in the SCSI attached storage system. This is equal to cpqFcaCntlrBoxIoSlot from the Fibre Channel Array Controller Table.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..255  

cpqSsScsiAttachmentPathStatus 1.3.6.1.4.1.232.8.2.2.8.1.8
Storage System SCSI Attachment Path Status. This is the status of this path to the chassis. The following values are defined: other(1) The agent does not recognize the status. You may need to upgrade your software. ok(2) The path is operating normally. offline(3) The path is offline.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(1), ok(2), offline(3)  

cpqSsScsiAttachmentPathCondition 1.3.6.1.4.1.232.8.2.2.8.1.9
Storage System SCSI Attachment Path Condition. This is the condition of this path to the chassis.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(1), ok(2), degraded(3), failed(4)  

cpqSsDrvBoxPathTable 1.3.6.1.4.1.232.8.2.3
Drive Box Access Path Table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    CpqSsDrvBoxPathEntry

cpqSsDrvBoxPathEntry 1.3.6.1.4.1.232.8.2.3.1
Drive Box Access Path Entry.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  CpqSsDrvBoxPathEntry  

cpqSsDrvBoxPathCntlrIndex 1.3.6.1.4.1.232.8.2.3.1.1
Drive Box Access Path Controller Index. The controller index indicates to which adapter card instance this table entry belongs.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cpqSsDrvBoxPathBoxIndex 1.3.6.1.4.1.232.8.2.3.1.2
Drive Box Access Path Box Index. The box index indicates to which box instance on an adapter card this table entry belongs. The value of this index is the same as cpqSsDrvBoxBusIndex used under the drive box table.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cpqSsDrvBoxPathIndex 1.3.6.1.4.1.232.8.2.3.1.3
Drive Box Access Path Index. This path index keeps track of multiple instances of access paths from a controller to a storage box. This number, along with the cpqSsDrvBoxPathCntlrIndex and cpqSsDrvBoxPathDrvIndex uniquely identify a specific storage box access path
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cpqSsDrvBoxPathStatus 1.3.6.1.4.1.232.8.2.3.1.4
Drive Box Access Path Status. This shows the status of the drive box access path. The following values are valid: Other (1) Indicates that the instrument agent can not determine the status of this access path. OK (2) Indicates the access path is functioning properly. Link Down (3) Indicates that the controller can no longer access the drive box through this path.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(1), ok(2), linkDown(3)  

cpqSsDrvBoxPathCurrentRole 1.3.6.1.4.1.232.8.2.3.1.5
Drive Box Access Path Current Role. This shows the current role of drive box acess path. The following values are valid: Other (1) Indicates that the instrument agent does not recognize the role of this access path. Active (2) Indicates that this path is currently the default active I/O path to access the drive box from the controller. Alternate (3) Indicates that this path is currently the alternate I/O path to access the physical drive from the controller.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(1), active(2), alternate(3)  

cpqSsDrvBoxPathHostConnector 1.3.6.1.4.1.232.8.2.3.1.6
Drive Box Access Path Host Connector. This is the host connector to which the access path is ultimately attached. If the host connector cannot be determined, the agent will return a NULL string.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..4)  

cpqSsDrvBoxPathBoxOnConnector 1.3.6.1.4.1.232.8.2.3.1.7
Drive Box Access Path Box on Connector. The box on connector indicates to which box instance this access path belongs.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cpqSsDrvBoxPathLocationString 1.3.6.1.4.1.232.8.2.3.1.8
Drive Box Access Path Location String. This string describes drive box access path in relation to the controller to which it is attached. If the location string cannot be determined, the agent will return a NULL string.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

cpqSsTrapPkts 1.3.6.1.4.1.232.8.3.1
The total number of trap packets issued by the enterprise since the instrument agent was loaded.
Status: deprecated Access: read-only
OBJECT-TYPE    
  Counter  

cpqSsTrapLogMaxSize 1.3.6.1.4.1.232.8.3.2
The maximum number of entries that will currently be kept in the trap log. If the maximum size has been reached and a new trap occurs the oldest trap will be removed.
Status: deprecated Access: read-only
OBJECT-TYPE    
  INTEGER 0..2147483647  

cpqSsTrapLogTable 1.3.6.1.4.1.232.8.3.3
An ordered list of trap log entries (conceptually a queue). The trap log entries will be kept in the order in which they were generated with the most recent trap at index 1 and the oldest trap entry at index trapLogMaxSize. If the maximum number size has been reached and a new trap occurs the oldest trap will be removed when the new trap is added so the trapMaxLogSize is not exceeded.
Status: deprecated Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    CpqSsTrapLogEntry

cpqSsTrapLogEntry 1.3.6.1.4.1.232.8.3.3.1
A description of a trap event.
Status: deprecated Access: not-accessible
OBJECT-TYPE    
  CpqSsTrapLogEntry  

cpqSsTrapLogIndex 1.3.6.1.4.1.232.8.3.3.1.1
The value of this object uniquely identifies this trapLogEntry at this time. The most recent trap will have an index of 1 and the oldest trap will have an index of trapLogMaxSize. Because of the queue-like nature of the trapLog this particular trap event's index will change as new traps are issued.
Status: deprecated Access: read-only
OBJECT-TYPE    
  INTEGER 0..2147483647  

cpqSsTrapType 1.3.6.1.4.1.232.8.3.3.1.2
The type of the trap event that this entry describes. This number refers to an entry in a list of traps enumerating the possible traps the agent may issue.
Status: deprecated Access: read-only
OBJECT-TYPE    
  INTEGER cpqSsFanStatusChange(1), cpqSs2FanStatusChange(8001), cpqSsTempFailed(8002), cpqSsTempDegraded(8003), cpqSsTempOk(8004), cpqSsSidePanelInPlace(8005), cpqSsSidePanelRemoved(8006)  

cpqSsTrapTime 1.3.6.1.4.1.232.8.3.3.1.3
The time of the trap event that this entry describes. The time is given in year (first octet), month, day of month, hour, minute, second (last octet) order. Each octet gives the value in BCD.
Status: deprecated Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(6)  

cpqSsRaidSystemTable 1.3.6.1.4.1.232.8.4.1
RAID Storage System Table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    CpqSsRaidSystemEntry

cpqSsRaidSystemEntry 1.3.6.1.4.1.232.8.4.1.1
RAID Storage System Entry.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  CpqSsRaidSystemEntry  

cpqSsRaidSystemIndex 1.3.6.1.4.1.232.8.4.1.1.1
RAID Storage System Index. The RAID Storage System index indicates to which storage system instance this table entry belongs.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..255  

cpqSsRaidSystemName 1.3.6.1.4.1.232.8.4.1.1.2
RAID Storage System Name. This is a description of the RAID Storage System's name. This can be used for identification purposes.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

cpqSsRaidSystemStatus 1.3.6.1.4.1.232.8.4.1.1.3
RAID Storage System Status. This is the current status of the RAID Storage System. This value will be one of the following: other(1) Indicates that the agent does not recognize the state of the RAID Storage System. You may need to upgrade the agent. agentNotRunning(2) Indicates that the Storage Work agent is not running. You need to restart the Storage Work agent. good(3) Indicates that the system is operating properly. warning(4) At least one component of the system failed. communicationLoss(5) The RAID Storage System has a cable or communication problem. Please check all cable connects to the host server.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(1), agentNotRunning(2), good(3), warning(4), communicationLoss(5)  

cpqSsRaidSystemCondition 1.3.6.1.4.1.232.8.4.1.1.4
RAID Storage System Condition. This is the overall condition of the storage system. The following values are defined: other(1) The agent does not recognize the status. You may need to upgrade your software. ok(2) The storage system is operating normally. No user action is required. degraded(3) The storage system is degraded. At least one component of the storage system failed. failed(4) The storage system has failed.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(1), ok(2), degraded(3), failed(4)  

cpqSsRaidSystemCntlr1SerialNumber 1.3.6.1.4.1.232.8.4.1.1.5
RAID Storage System Controller 1 Serial Number. This is the controller number 1's serial number which is normally display on the front panel. This can be used for identification purposes.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..24)  

cpqSsRaidSystemCntlr2SerialNumber 1.3.6.1.4.1.232.8.4.1.1.6
RAID Storage System Controller 2 Serial Number. This is the controller number 2's serial number which is normally display on the front panel. This can be used for identification purposes.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..24)  

cpqSsFanStatusChange 1
Storage System fan status change. The agent has detected a change in the Fan Status of a storage system. The variable cpqSsBoxFanStatus indicates the current fan status.
TRAP-TYPE    

cpqSs2FanStatusChange 8001
Storage System fan status change. The agent has detected a change in the Fan Status of a storage system. The variable cpqSsBoxFanStatus indicates the current fan status.
TRAP-TYPE    

cpqSsTempFailed 8002
Storage System temperature failure. The agent has detected that a temperature status has been set to failed. The storage system will be shutdown.
TRAP-TYPE    

cpqSsTempDegraded 8003
Storage System temperature degraded. The agent has detected a temperature status that has been set to degraded. The storage system's temperature is outside of the normal operating range.
TRAP-TYPE    

cpqSsTempOk 8004
Storage System temperature ok. The temperature status has been set to OK. The storage system's temperature has returned to normal operating range. It may be reactivated by the administrator.
TRAP-TYPE    

cpqSsSidePanelInPlace 8005
Storage System side panel is in place. The side panel status has been set to in place. The storage system's side panel has returned to a properly installed state.
TRAP-TYPE    

cpqSsSidePanelRemoved 8006
Storage System side panel is removed. The side panel status has been set to removed. The storage system's side panel is not in a properly installed state. This situation may result in improper cooling of the drives in the storage system due to air flow changes caused by the missing side panel.
TRAP-TYPE    

cpqSsPwrSupplyDegraded 8007
A storage system power supply status has been set to degraded.
TRAP-TYPE    

cpqSs3FanStatusChange 8008
Storage System fan status change. The agent has detected a change in the Fan Status of a storage system. The variable cpqSsBoxFanStatus indicates the current fan status. User Action: If the fan status is degraded or failed, replace any failed fans.
TRAP-TYPE    

cpqSs3TempFailed 8009
Storage System temperature failure. The agent has detected that a temperature status has been set to failed. The storage system will be shutdown. User Action: Shutdown the storage system as soon as possible. Insure that the storage system environment is being cooled properly and that no components are overheated.
TRAP-TYPE    

cpqSs3TempDegraded 8010
Storage System temperature degraded. The agent has detected a temperature status that has been set to degraded. The storage system's temperature is outside of the normal operating range. User Action: Shutdown the storage system as soon as possible. Insure that the storage system environment is being cooled properly and that no components are overheated.
TRAP-TYPE    

cpqSs3TempOk 8011
Storage System temperature ok. The temperature status has been set to OK. The storage system's temperature has returned to normal operating range. It may be reactivated by the administrator. User Action: None.
TRAP-TYPE    

cpqSs3SidePanelInPlace 8012
Storage System side panel is in place. The side panel status has been set to in place. The storage system's side panel has returned to a properly installed state. User Action: None.
TRAP-TYPE    

cpqSs3SidePanelRemoved 8013
Storage System side panel is removed. The side panel status has been set to removed. The storage system's side panel is not in a properly installed state. This situation may result in improper cooling of the drives in the storage system due to air flow changes caused by the missing side panel. User Action: Replace the storage system side panel.
TRAP-TYPE    

cpqSs3PwrSupplyDegraded 8014
A storage system power supply status has been set to degraded.
TRAP-TYPE    

cpqSs4PwrSupplyDegraded 8015
A storage system power supply status has been set to degraded. User Action: Take action to restore power or replace any failed storage system power supply.
TRAP-TYPE    

cpqSsExFanStatusChange 8016
Storage system fan status change. The agent has detected a change in the Fan Module Status of a storage system. The variable cpqSsFanModuleStatus indicates the current fan status. User Action: If the fan status is degraded or failed, replace any failed fans.
TRAP-TYPE    

cpqSsExPowerSupplyStatusChange 8017
Storage system power supply status change. The agent has detected a change in the power supply status of a storage system. The variable cpqSsPowerSupplyStatus indicates the current status. User Action: If the power supply status is failed, take action to restore power or replace the failed power supply.
TRAP-TYPE    

cpqSsExPowerSupplyUpsStatusChange 8018
Storage system power supply UPS status change. The agent has detected a change status of a UPS attached to a storage system power supply. The variable cpqSsPowerSupplyUpsStatus indicates the current status. User Action: If the UPS status is powerFailed(4) or batteryLow(5), take action to restore power to the UPS.
TRAP-TYPE    

cpqSsExTempSensorStatusChange 8019
Storage system temperature sensor status change. The agent has detected a change in the status of a storage system temperature sensor. The variable cpqSsTempSensorStatus indicates the current status. User Action: If the temperature status is degraded or failed, shutdown the storage system as soon as possible. Insure that the storage system environment is being cooled properly and that no components are overheated.
TRAP-TYPE    

cpqSsEx2FanStatusChange 8020
Storage system fan status change. The agent has detected a change in the fan module status of a storage system. The variable cpqSsFanModuleStatus indicates the current fan status. User Action: If the fan status is degraded or failed, replace any failed fans.
TRAP-TYPE    

cpqSsEx2PowerSupplyStatusChange 8021
Storage system power supply status change. The agent has detected a change in the power supply status of a storage system. The variable cpqSsPowerSupplyStatus indicates the current status. User Action: If the power supply status is failed, take action to restore power or replace the failed power supply.
TRAP-TYPE    

cpqSsExBackplaneFanStatusChange 8022
Storage system fan status change. The agent has detected a change in the fan status of a storage system. The variable cpqSsBackplaneFanStatus indicates the current fan status. User Action: If the fan status is degraded or failed, replace any failed fans.
TRAP-TYPE    

cpqSsExBackplaneTempStatusChange 8023
Storage system temperature status change. The agent has detected a change in the status of the temperature in a storage system. The variable cpqSsBackplaneTempStatus indicates the current status. User Action: If the temperature status is degraded or failed, shutdown the storage system as soon as possible. Insure that the storage system environment is being cooled properly and that no components are overheated.
TRAP-TYPE    

cpqSsExBackplanePowerSupplyStatusChange 8024
Storage system power supply status change. The agent has detected a change in the power supply status of a storage system. The variable cpqSsBackplaneFtpsStatus indicates the current status. User Action: If the power supply status is degraded, take action to restore power or replace the failed power supply.
TRAP-TYPE    

cpqSsExRecoveryServerStatusChange 8025
Storage system recovery server option status change. The agent has detected a change in the recovery server option status of a storage system. The variable cpqSsChassisRsoStatus indicates the current status. User Action: If the RSO status is noSecondary(6) or linkDown(7), insure the secondary server is operational and all cables are connected properly. If the RSO status is secondaryRunningAuto(8) or secondaryRunningUser(9), examine the the primary server for failed components.
TRAP-TYPE    

cpqSs5FanStatusChange 8026
Storage System fan status change. The agent has detected a change in the Fan Status of a storage system. The variable cpqSsBoxFanStatus indicates the current fan status. User Action: If the fan status is degraded or failed, replace any failed fans.
TRAP-TYPE    

cpqSs5TempStatusChange 8027
Storage System temperature status change. The agent has detected a change in the temperature status of a storage system. The variable cpqSsBoxTempStatus indicates the current temperature status. User Action: If the temperature status is degraded or failed, shutdown the storage system as soon as possible. Insure that the storage system environment is being cooled properly and that no components are overheated.
TRAP-TYPE    

cpqSs5PwrSupplyStatusChange 8028
Storage system power supply status change. The agent has detected a change in the power supply status of a storage system. The variable cpqSsBoxFltTolPwrSupplyStatus indicates the current power supply status. User Action: If the power supply status is degraded, take action to restore power or replace the failed power supply.
TRAP-TYPE    

cpqSs6FanStatusChange 8029
Storage System fan status change. The agent has detected a change in the Fan Status of a storage system. The variable cpqSsBoxFanStatus indicates the current fan status. User Action: If the fan status is degraded or failed, replace any failed fans.
TRAP-TYPE    

cpqSs6TempStatusChange 8030
Storage System temperature status change. The agent has detected a change in the temperature status of a storage system. The variable cpqSsBoxTempStatus indicates the current temperature status. User Action: If the temperature status is degraded or failed, shutdown the storage system as soon as possible. Insure that the storage system environment is being cooled properly and that no components are overheated.
TRAP-TYPE    

cpqSs6PwrSupplyStatusChange 8031
Storage system power supply status change. The agent has detected a change in the power supply status of a storage system. The variable cpqSsBoxFltTolPwrSupplyStatus indicates the current power supply status. User Action: If the power supply status is degraded, take action to restore power or replace the failed power supply.
TRAP-TYPE    

cpqSsConnectionStatusChange 8032
Storage system connection status change. The agent has detected a change in the connection status of a storage system. The variable cpqSSboxConnectionStatus indicates the current connection status. User Action: If the connection status is disconnected, take action to restore the connection between the HBA and the storage system
TRAP-TYPE