CpqSsDrvBoxEntry |
|
SEQUENCE |
|
|
|
|
cpqSsBoxCntlrIndex |
INTEGER |
|
|
cpqSsBoxBusIndex |
INTEGER |
|
|
cpqSsBoxType |
INTEGER |
|
|
cpqSsBoxModel |
DisplayString |
|
|
cpqSsBoxFWRev |
DisplayString |
|
|
cpqSsBoxVendor |
DisplayString |
|
|
cpqSsBoxFanStatus |
INTEGER |
|
|
cpqSsBoxCondition |
INTEGER |
|
|
cpqSsBoxTempStatus |
INTEGER |
|
|
cpqSsBoxSidePanelStatus |
INTEGER |
|
|
cpqSsBoxFltTolPwrSupplyStatus |
INTEGER |
|
|
cpqSsBoxBackPlaneVersion |
INTEGER |
|
|
cpqSsBoxTotalBays |
INTEGER |
|
|
cpqSsBoxPlacement |
INTEGER |
|
|
cpqSsBoxDuplexOption |
INTEGER |
|
|
cpqSsBoxBoardRevision |
INTEGER |
|
|
cpqSsBoxSerialNumber |
DisplayString |
|
|
cpqSsBoxCntlrHwLocation |
DisplayString |
|
|
cpqSsBoxBackplaneSpeed |
INTEGER |
|
|
cpqSsBoxConnectionType |
INTEGER |
|
|
cpqSsBoxHostConnector |
DisplayString |
|
|
cpqSsBoxBoxOnConnector |
INTEGER |
|
|
cpqSsBoxLocationString |
DisplayString |
|
|
cpqSsBoxInitiatorSasAddress |
DisplayString |
|
|
cpqSsBoxTargetSasAddress |
DisplayString |
|
|
cpqSsBoxLocalManageIpAddress |
DisplayString |
|
|
cpqSsBoxPartnerManageIpAddress |
DisplayString |
|
|
cpqSsBoxConnectionStatus |
INTEGER |
|
|
cpqSsBoxTargetBasedManagement |
INTEGER |
|
CpqSsChassisEntry |
|
SEQUENCE |
|
|
|
|
cpqSsChassisIndex |
INTEGER |
|
|
cpqSsChassisConnectionType |
INTEGER |
|
|
cpqSsChassisSerialNumber |
DisplayString |
|
|
cpqSsChassisName |
DisplayString |
|
|
cpqSsChassisSystemBoardSerNum |
DisplayString |
|
|
cpqSsChassisSystemBoardRev |
DisplayString |
|
|
cpqSsChassisPowerBoardSerNum |
DisplayString |
|
|
cpqSsChassisPowerBoardRev |
DisplayString |
|
|
cpqSsChassisScsiBoardSerNum |
DisplayString |
|
|
cpqSsChassisScsiBoardRev |
DisplayString |
|
|
cpqSsChassisOverallCondition |
INTEGER |
|
|
cpqSsChassisPowerSupplyCondition |
INTEGER |
|
|
cpqSsChassisFanCondition |
INTEGER |
|
|
cpqSsChassisTemperatureCondition |
INTEGER |
|
|
cpqSsChassisFcaCntlrCondition |
INTEGER |
|
|
cpqSsChassisFcaLogicalDriveCondition |
INTEGER |
|
|
cpqSsChassisFcaPhysDrvCondition |
INTEGER |
|
|
cpqSsChassisTime |
INTEGER |
|
|
cpqSsChassisModel |
INTEGER |
|
|
cpqSsChassisBackplaneCondition |
INTEGER |
|
|
cpqSsChassisFcaTapeDrvCondition |
INTEGER |
|
|
cpqSsChassisRsoStatus |
INTEGER |
|
|
cpqSsChassisRsoCondition |
INTEGER |
|
|
cpqSsChassisScsiIoModuleType |
INTEGER |
|
|
cpqSsChassisPreferredPathMode |
INTEGER |
|
|
cpqSsChassisProductId |
DisplayString |
|
CpqSsIoSlotEntry |
|
SEQUENCE |
|
|
|
|
cpqSsIoSlotChassisIndex |
INTEGER |
|
|
cpqSsIoSlotIndex |
INTEGER |
|
|
cpqSsIoSlotControllerType |
INTEGER |
|
CpqSsPowerSupplyEntry |
|
SEQUENCE |
|
|
|
|
cpqSsPowerSupplyChassisIndex |
INTEGER |
|
|
cpqSsPowerSupplyIndex |
INTEGER |
|
|
cpqSsPowerSupplyBay |
INTEGER |
|
|
cpqSsPowerSupplyStatus |
INTEGER |
|
|
cpqSsPowerSupplyUpsStatus |
INTEGER |
|
|
cpqSsPowerSupplyCondition |
INTEGER |
|
|
cpqSsPowerSupplySerialNumber |
DisplayString |
|
|
cpqSsPowerSupplyBoardRevision |
DisplayString |
|
|
cpqSsPowerSupplyFirmwareRevision |
DisplayString |
|
CpqSsFanModuleEntry |
|
SEQUENCE |
|
|
|
|
cpqSsFanModuleChassisIndex |
INTEGER |
|
|
cpqSsFanModuleIndex |
INTEGER |
|
|
cpqSsFanModuleStatus |
INTEGER |
|
|
cpqSsFanModuleCondition |
INTEGER |
|
|
cpqSsFanModuleLocation |
INTEGER |
|
|
cpqSsFanModuleSerialNumber |
DisplayString |
|
|
cpqSsFanModuleBoardRevision |
DisplayString |
|
CpqSsTempSensorEntry |
|
SEQUENCE |
|
|
|
|
cpqSsTempSensorChassisIndex |
INTEGER |
|
|
cpqSsTempSensorIndex |
INTEGER |
|
|
cpqSsTempSensorStatus |
INTEGER |
|
|
cpqSsTempSensorCondition |
INTEGER |
|
|
cpqSsTempSensorLocation |
INTEGER |
|
|
cpqSsTempSensorCurrentValue |
INTEGER |
|
|
cpqSsTempSensorLimitValue |
INTEGER |
|
|
cpqSsTempSensorHysteresisValue |
INTEGER |
|
CpqSsBackplaneEntry |
|
SEQUENCE |
|
|
|
|
cpqSsBackplaneChassisIndex |
INTEGER |
|
|
cpqSsBackplaneIndex |
INTEGER |
|
|
cpqSsBackplaneFWRev |
DisplayString |
|
|
cpqSsBackplaneDriveBays |
INTEGER |
|
|
cpqSsBackplaneDuplexOption |
INTEGER |
|
|
cpqSsBackplaneCondition |
INTEGER |
|
|
cpqSsBackplaneVersion |
INTEGER |
|
|
cpqSsBackplaneVendor |
DisplayString |
|
|
cpqSsBackplaneModel |
DisplayString |
|
|
cpqSsBackplaneFanStatus |
INTEGER |
|
|
cpqSsBackplaneTempStatus |
INTEGER |
|
|
cpqSsBackplaneFtpsStatus |
INTEGER |
|
|
cpqSsBackplaneSerialNumber |
DisplayString |
|
|
cpqSsBackplanePlacement |
INTEGER |
|
|
cpqSsBackplaneBoardRevision |
INTEGER |
|
|
cpqSsBackplaneSpeed |
INTEGER |
|
|
cpqSsBackplaneConnectionType |
INTEGER |
|
|
cpqSsBackplaneConnector |
DisplayString |
|
|
cpqSsBackplaneOnConnector |
INTEGER |
|
|
cpqSsBackplaneLocationString |
DisplayString |
|
CpqSsFibreAttachmentEntry |
|
SEQUENCE |
|
|
|
|
cpqSsFibreAttachmentIndex |
INTEGER |
|
|
cpqSsFibreAttachmentHostControllerIndex |
INTEGER |
|
|
cpqSsFibreAttachmentHostControllerPort |
INTEGER |
|
|
cpqSsFibreAttachmentDeviceType |
INTEGER |
|
|
cpqSsFibreAttachmentDeviceIndex |
INTEGER |
|
|
cpqSsFibreAttachmentDevicePort |
INTEGER |
|
CpqSsScsiAttachmentEntry |
|
SEQUENCE |
|
|
|
|
cpqSsScsiAttachmentIndex |
INTEGER |
|
|
cpqSsScsiAttachmentControllerIndex |
INTEGER |
|
|
cpqSsScsiAttachmentControllerPort |
INTEGER |
|
|
cpqSsScsiAttachmentControllerTarget |
INTEGER |
|
|
cpqSsScsiAttachmentControllerLun |
INTEGER |
|
|
cpqSsScsiAttachmentChassisIndex |
INTEGER |
|
|
cpqSsScsiAttachmentChassisIoSlot |
INTEGER |
|
|
cpqSsScsiAttachmentPathStatus |
INTEGER |
|
|
cpqSsScsiAttachmentPathCondition |
INTEGER |
|
CpqSsDrvBoxPathEntry |
|
SEQUENCE |
|
|
|
|
cpqSsDrvBoxPathCntlrIndex |
INTEGER |
|
|
cpqSsDrvBoxPathBoxIndex |
INTEGER |
|
|
cpqSsDrvBoxPathIndex |
INTEGER |
|
|
cpqSsDrvBoxPathStatus |
INTEGER |
|
|
cpqSsDrvBoxPathCurrentRole |
INTEGER |
|
|
cpqSsDrvBoxPathHostConnector |
DisplayString |
|
|
cpqSsDrvBoxPathBoxOnConnector |
INTEGER |
|
|
cpqSsDrvBoxPathLocationString |
DisplayString |
|
CpqSsRaidSystemEntry |
|
SEQUENCE |
|
|
|
|
cpqSsRaidSystemIndex |
INTEGER |
|
|
cpqSsRaidSystemName |
DisplayString |
|
|
cpqSsRaidSystemStatus |
INTEGER |
|
|
cpqSsRaidSystemCondition |
INTEGER |
|
|
cpqSsRaidSystemCntlr1SerialNumber |
DisplayString |
|
|
cpqSsRaidSystemCntlr2SerialNumber |
DisplayString |
|
cpqSsChassisEntry |
1.3.6.1.4.1.232.8.2.2.1.1 |
Storage System Chassis Entry. |
Status: mandatory |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
CpqSsChassisEntry |
|
|
cpqSsChassisRsoStatus |
1.3.6.1.4.1.232.8.2.2.1.1.22 |
Storage System Chassis Recovery Server Option Status.
The following values are defined:
other(1)
The recovery server option status cannot be determined for
this storage system.
notSupported(2)
The recovery server option is not supported for this storage
system.
notConfigured(3)
The recovery server option is supported, but is not
configured on this storage system.
disabled(4)
The recovery server option is configured as primary, but
has been disabled by software.
daemonDownDisabled(5)
The recovery server option operating system daemon is no
longer running. The last status of RSO was disabled(4).
ok(6)
The recovery server option is configured as primary and
everything is working correctly.
daemonDownActive(7)
The recovery server option operating system daemon is no
longer running. The last status of RSO was ok(6).
noSecondary(8)
The recovery server option is configured as primary, but
communication with the standby server has not been established.
daemonDownNoSecondary(9)
The recovery server option operating system daemon is no
longer running. The last status of RSO was noSecondary(8).
linkDown(10)
The recovery server option is configured as primary, but
communication with the standby server has failed.
daemonDownLinkDown(11)
The recovery server option operating system daemon is no
longer running. The last status of RSO was linkDown(10).
secondaryRunningAuto(12)
The recovery server option is configured and the standby
server is running. The secondary server assumed control
after communication with the primary server failed.
secondaryRunningUser(13)
The recovery server option is configured and the standby
server is running. A user forced the secondary server to
assume control.
evTimeoutError(14)
The recovery server option environment variable cannot be
accessed. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
other(1), notSupported(2), notConfigured(3), disabled(4), daemonDownDisabled(5), ok(6), daemonDownActive(7), noSecondary(8), daemonDownNoSecondary(9), linkDown(10), daemonDownLinkDown(11), secondaryRunningAuto(12), secondaryRunningUser(13), evTimeoutError(14) |
|
cpqSsIoSlotEntry |
1.3.6.1.4.1.232.8.2.2.2.1 |
Storage System I/O Slot Entry. |
Status: mandatory |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
CpqSsIoSlotEntry |
|
|
cpqSsPowerSupplyEntry |
1.3.6.1.4.1.232.8.2.2.3.1 |
Storage System Power Supply Entry. |
Status: mandatory |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
CpqSsPowerSupplyEntry |
|
|
cpqSsFanModuleEntry |
1.3.6.1.4.1.232.8.2.2.4.1 |
Storage System Fan Module Entry. |
Status: mandatory |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
CpqSsFanModuleEntry |
|
|
cpqSsTempSensorEntry |
1.3.6.1.4.1.232.8.2.2.5.1 |
Storage System Temperature Sensor Entry. |
Status: mandatory |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
CpqSsTempSensorEntry |
|
|
cpqSsBackplaneEntry |
1.3.6.1.4.1.232.8.2.2.6.1 |
Storage System SCSI Backplane Entry. |
Status: mandatory |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
CpqSsBackplaneEntry |
|
|
cpqSsBackplaneFanStatus |
1.3.6.1.4.1.232.8.2.2.6.1.10 |
Storage System Backplane Fan Status.
This is the current status of the fans in the storage system.
This value will be one of the following:
other(1)
The agent is unable to determine if this storage system has
fan monitoring.
notInstalled(2)
This unit does not support fan monitoring.
ok(3)
All fans are working normally.
degraded(4)
At least one storage system fan has failed, but there is still
sufficient cooling capacity to allow the system to continue.
The fan should be replaced.
failed(5)
One or more storage system fans have failed. The fan(s) should
be replaced immediately to avoid hardware damage.
notSupported(6)
The storage system does not support reporting fan status
through this backplane. The fan status is reported through the
first backplane on this storage system.
degraded-Fan1Failed(7)
Fan 1 has failed, but there is still sufficient cooling
capacity to allow the system to continue. The fan should be
replaced.
degraded-Fan2Failed(8)
Fan 2 has failed, but there is still sufficient cooling
capacity to allow the system to continue. The fan should be
replaced. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
other(1), notInstalled(2), ok(3), degraded(4), failed(5), notSupported(6), degraded-Fan1Failed(7), degraded-Fan2Failed(8) |
|
cpqSsFibreAttachmentEntry |
1.3.6.1.4.1.232.8.2.2.7.1 |
Storage System Fibre Attachment Entry. |
Status: mandatory |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
CpqSsFibreAttachmentEntry |
|
|
cpqSsScsiAttachmentEntry |
1.3.6.1.4.1.232.8.2.2.8.1 |
Storage System SCSI Attachment Entry. |
Status: mandatory |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
CpqSsScsiAttachmentEntry |
|
|
cpqSsDrvBoxPathEntry |
1.3.6.1.4.1.232.8.2.3.1 |
Drive Box Access Path Entry. |
Status: mandatory |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
CpqSsDrvBoxPathEntry |
|
|
cpqSsTrapLogEntry |
1.3.6.1.4.1.232.8.3.3.1 |
A description of a trap event. |
Status: deprecated |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
CpqSsTrapLogEntry |
|
|
cpqSsRaidSystemEntry |
1.3.6.1.4.1.232.8.4.1.1 |
RAID Storage System Entry. |
Status: mandatory |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
CpqSsRaidSystemEntry |
|
|