CPQRACK-MIB

File: CPQRACK-MIB.mib (217330 bytes)

Imported modules

CPQHOST-MIB RFC1213-MIB RFC-1212
RFC-1215

Imported symbols

compaq DisplayString OBJECT-TYPE
sysName cpqHoTrapFlags TRAP-TYPE

Defined Types

CpqRackAssetEntry  
SEQUENCE    
  cpqRackAssetIndex INTEGER
  cpqRackName DisplayString
  cpqRackUid DisplayString
  cpqRackSerialNum DisplayString
  cpqRackTrapSequenceNum INTEGER
  cpqRackHeight INTEGER
  cpqRackWidth INTEGER
  cpqRackDepth INTEGER

CpqRackCommonEnclosureEntry  
SEQUENCE    
  cpqRackCommonEnclosureRack INTEGER
  cpqRackCommonEnclosureIndex INTEGER
  cpqRackCommonEnclosureModel DisplayString
  cpqRackCommonEnclosureAssetTag DisplayString
  cpqRackCommonEnclosurePartNumber DisplayString
  cpqRackCommonEnclosureSparePartNumber DisplayString
  cpqRackCommonEnclosureSerialNum DisplayString
  cpqRackCommonEnclosureFWRev DisplayString
  cpqRackCommonEnclosureName DisplayString
  cpqRackCommonEnclosureNeighborNamePrev DisplayString
  cpqRackCommonEnclosureNeighborNameNext DisplayString
  cpqRackCommonEnclosureHeight INTEGER
  cpqRackCommonEnclosureWidth INTEGER
  cpqRackCommonEnclosureDepth INTEGER
  cpqRackCommonEnclosureTrapSequenceNum INTEGER
  cpqRackCommonEnclosureCondition INTEGER
  cpqRackCommonEnclosureHasServerBlades INTEGER
  cpqRackCommonEnclosureHasPowerSupplies INTEGER
  cpqRackCommonEnclosureHasNetConnectors INTEGER
  cpqRackCommonEnclosureHasTempSensors INTEGER
  cpqRackCommonEnclosureHasFans INTEGER
  cpqRackCommonEnclosureHasFuses INTEGER
  cpqRackCommonEnclosureMgmtUID INTEGER
  cpqRackCommonEnclosureSerialNumPrev DisplayString
  cpqRackCommonEnclosureSerialNumNext DisplayString
  cpqRackCommonEnclosureAddress INTEGER
  cpqRackCommonEnclosureProductId DisplayString
  cpqRackCommonEnclosureProductIdPrev DisplayString
  cpqRackCommonEnclosureProductIdNext DisplayString
  cpqRackCommonEnclosureUUID DisplayString
  cpqRackCommonEnclosureUUIDPrev DisplayString
  cpqRackCommonEnclosureUUIDNext DisplayString
  cpqRackCommonEnclosureHasManagers INTEGER

CpqRackCommonEnclosureTempEntry  
SEQUENCE    
  cpqRackCommonEnclosureTempRack INTEGER
  cpqRackCommonEnclosureTempChassis INTEGER
  cpqRackCommonEnclosureTempSensorIndex INTEGER
  cpqRackCommonEnclosureTempSensorEnclosureName DisplayString
  cpqRackCommonEnclosureTempLocation DisplayString
  cpqRackCommonEnclosureTempCurrent INTEGER
  cpqRackCommonEnclosureTempThreshold INTEGER
  cpqRackCommonEnclosureTempCondition INTEGER
  cpqRackCommonEnclosureTempType INTEGER
  cpqRackCommonEnclosureTempSensorEnclosureSerialNum DisplayString

CpqRackCommonEnclosureFanEntry  
SEQUENCE    
  cpqRackCommonEnclosureFanRack INTEGER
  cpqRackCommonEnclosureFanChassis INTEGER
  cpqRackCommonEnclosureFanIndex INTEGER
  cpqRackCommonEnclosureFanEnclosureName DisplayString
  cpqRackCommonEnclosureFanLocation DisplayString
  cpqRackCommonEnclosureFanPartNumber DisplayString
  cpqRackCommonEnclosureFanSparePartNumber DisplayString
  cpqRackCommonEnclosureFanPresent INTEGER
  cpqRackCommonEnclosureFanRedundant INTEGER
  cpqRackCommonEnclosureFanRedundantGroupId INTEGER
  cpqRackCommonEnclosureFanCondition INTEGER
  cpqRackCommonEnclosureFanEnclosureSerialNum DisplayString

CpqRackCommonEnclosureFuseEntry  
SEQUENCE    
  cpqRackCommonEnclosureFuseRack INTEGER
  cpqRackCommonEnclosureFuseChassis INTEGER
  cpqRackCommonEnclosureFuseIndex INTEGER
  cpqRackCommonEnclosureFuseEnclosureName DisplayString
  cpqRackCommonEnclosureFuseLocation DisplayString
  cpqRackCommonEnclosureFusePresent INTEGER
  cpqRackCommonEnclosureFuseCondition INTEGER

CpqRackCommonEnclosureFruEntry  
SEQUENCE    
  cpqRackCommonEnclosureFruRack INTEGER
  cpqRackCommonEnclosureFruChassis INTEGER
  cpqRackCommonEnclosureFruIndex INTEGER
  cpqRackCommonEnclosureFruEnclosureName DisplayString
  cpqRackCommonEnclosureFruDescription DisplayString
  cpqRackCommonEnclosureFruLocation DisplayString
  cpqRackCommonEnclosureFruAssemblyPartNumber DisplayString
  cpqRackCommonEnclosureFruSparePartNumber DisplayString
  cpqRackCommonEnclosureFruAutoRev DisplayString
  cpqRackCommonEnclosureFruSerialNum DisplayString

CpqRackCommonEnclosureManagerEntry  
SEQUENCE    
  cpqRackCommonEnclosureManagerRack INTEGER
  cpqRackCommonEnclosureManagerChassis INTEGER
  cpqRackCommonEnclosureManagerIndex INTEGER
  cpqRackCommonEnclosureManagerEnclosureName DisplayString
  cpqRackCommonEnclosureManagerLocation DisplayString
  cpqRackCommonEnclosureManagerPartNumber DisplayString
  cpqRackCommonEnclosureManagerSparePartNumber DisplayString
  cpqRackCommonEnclosureManagerSerialNum DisplayString
  cpqRackCommonEnclosureManagerRole INTEGER
  cpqRackCommonEnclosureManagerPresent INTEGER
  cpqRackCommonEnclosureManagerRedundant INTEGER
  cpqRackCommonEnclosureManagerCondition INTEGER
  cpqRackCommonEnclosureManagerEnclosureSerialNum DisplayString
  cpqRackCommonEnclosureManagerUUID DisplayString
  cpqRackCommonEnclosureManagerFWRev DisplayString

CpqRackServerEnclosureEntry  
SEQUENCE    
  cpqRackServerEnclosureRack INTEGER
  cpqRackServerEnclosureIndex INTEGER
  cpqRackServerEnclosureName DisplayString
  cpqRackServerEnclosureMaxNumBlades INTEGER
  cpqRackServerEnclosureMaxNumBladesX INTEGER
  cpqRackServerEnclosureMaxNumBladesY INTEGER

CpqRackPowerEnclosureEntry  
SEQUENCE    
  cpqRackPowerEnclosureRack INTEGER
  cpqRackPowerEnclosureIndex INTEGER
  cpqRackPowerEnclosureName DisplayString
  cpqRackPowerEnclosureMgmtBoardSerialNum DisplayString
  cpqRackPowerEnclosureRedundant INTEGER
  cpqRackPowerEnclosureLoadBalanced INTEGER
  cpqRackPowerEnclosureInputPwrType INTEGER
  cpqRackPowerEnclosurePwrFeedMax INTEGER
  cpqRackPowerEnclosureCondition INTEGER
  cpqRackPowerEnclosureBladeAutopoweron INTEGER

CpqRackServerBladeEntry  
SEQUENCE    
  cpqRackServerBladeRack INTEGER
  cpqRackServerBladeChassis INTEGER
  cpqRackServerBladeIndex INTEGER
  cpqRackServerBladeName DisplayString
  cpqRackServerBladeEnclosureName DisplayString
  cpqRackServerBladePartNumber DisplayString
  cpqRackServerBladeSparePartNumber DisplayString
  cpqRackServerBladePosition INTEGER
  cpqRackServerBladeHeight INTEGER
  cpqRackServerBladeWidth INTEGER
  cpqRackServerBladeDepth INTEGER
  cpqRackServerBladePresent INTEGER
  cpqRackServerBladeHasFuses INTEGER
  cpqRackServerBladeEnclosureSerialNum DisplayString
  cpqRackServerBladeSlotsUsed INTEGER
  cpqRackServerBladeSerialNum DisplayString
  cpqRackServerBladeProductId DisplayString
  cpqRackServerBladeUid DisplayString
  cpqRackServerBladeSlotsUsedX INTEGER
  cpqRackServerBladeSlotsUsedY INTEGER
  cpqRackServerBladeStatus INTEGER
  cpqRackServerBladeFaultMajor INTEGER
  cpqRackServerBladeFaultMinor INTEGER
  cpqRackServerBladeFaultDiagnosticString DisplayString
  cpqRackServerBladePowered INTEGER
  cpqRackServerBladeUIDState INTEGER
  cpqRackServerBladeSystemBIOSRevision DisplayString
  cpqRackServerBladeSystemBIOSFlashingStatus INTEGER
  cpqRackServerBladeHasManagementDevice INTEGER
  cpqRackServerBladeManagementDeviceFirmwareRevision DisplayString
  cpqRackServerBladeManagementDeviceFirmwareFlashingStatus INTEGER
  cpqRackServerBladeDiagnosticAdaptorPresence INTEGER
  cpqRackServerBladeASREnabled INTEGER
  cpqRackServerBladeFrontIOBlankingModeStatus INTEGER
  cpqRackServerBladePOSTStatus INTEGER
  cpqRackServerBladePXEBootModeStatus INTEGER
  cpqRackServerBladePendingBootOrderChange INTEGER
  cpqRackServerBladeWattageMax INTEGER
  cpqRackServerBladeWattageAvg INTEGER
  cpqRackServerBladeWattageMin INTEGER

CpqRackServerNetworkingEntry  
SEQUENCE    
  cpqRackServerNetworkingRack INTEGER
  cpqRackServerNetworkingChassis INTEGER
  cpqRackServerNetworkingIndex INTEGER
  cpqRackServerNetworkingName DisplayString
  cpqRackServerNetworkingEnclosureName DisplayString
  cpqRackServerNetworkingEthernetInterfaces INTEGER
  cpqRackServerNetworkingEthernetMACAddress DisplayString

CpqRackServerTempSensorEntry  
SEQUENCE    
  cpqRackServerTempSensorRack INTEGER
  cpqRackServerTempSensorChassis INTEGER
  cpqRackServerTempSensorIndex INTEGER
  cpqRackServerTempSensorName DisplayString
  cpqRackServerTempSensorEnclosureName DisplayString
  cpqRackServerTempSensorCount INTEGER
  cpqRackServerTempSensorLocation DisplayString
  cpqRackServerTempSensorCurrent INTEGER
  cpqRackServerTempSensorThreshold INTEGER
  cpqRackServerTempSensorCondition INTEGER
  cpqRackServerTempSensorType INTEGER

CpqRackPowerSupplyEntry  
SEQUENCE    
  cpqRackPowerSupplyRack INTEGER
  cpqRackPowerSupplyChassis INTEGER
  cpqRackPowerSupplyIndex INTEGER
  cpqRackPowerSupplyEnclosureName DisplayString
  cpqRackPowerSupplySerialNum DisplayString
  cpqRackPowerSupplyPartNumber DisplayString
  cpqRackPowerSupplySparePartNumber DisplayString
  cpqRackPowerSupplyFWRev DisplayString
  cpqRackPowerSupplyMaxPwrOutput INTEGER
  cpqRackPowerSupplyCurPwrOutput INTEGER
  cpqRackPowerSupplyPosition INTEGER
  cpqRackPowerSupplyIntakeTemp INTEGER
  cpqRackPowerSupplyExhaustTemp INTEGER
  cpqRackPowerSupplyStatus INTEGER
  cpqRackPowerSupplyInputLineStatus INTEGER
  cpqRackPowerSupplyPresent INTEGER
  cpqRackPowerSupplyCondition INTEGER
  cpqRackPowerSupplyEnclosureSerialNum DisplayString

CpqRackNetConnectorEntry  
SEQUENCE    
  cpqRackNetConnectorRack INTEGER
  cpqRackNetConnectorChassis INTEGER
  cpqRackNetConnectorIndex INTEGER
  cpqRackNetConnectorEnclosureName DisplayString
  cpqRackNetConnectorName DisplayString
  cpqRackNetConnectorModel DisplayString
  cpqRackNetConnectorSerialNum DisplayString
  cpqRackNetConnectorPartNumber DisplayString
  cpqRackNetConnectorSparePartNumber DisplayString
  cpqRackNetConnectorFWRev DisplayString
  cpqRackNetConnectorType INTEGER
  cpqRackNetConnectorLocation DisplayString
  cpqRackNetConnectorPresent INTEGER
  cpqRackNetConnectorHasFuses INTEGER
  cpqRackNetConnectorEnclosureSerialNum DisplayString
  cpqRackNetConnectorTechnologyType INTEGER
  cpqRackNetConnectorDeviceType INTEGER

Defined Values

cpqRackInfo 1.3.6.1.4.1.232.22
OBJECT IDENTIFIER    

cpqRackMibRev 1.3.6.1.4.1.232.22.1
OBJECT IDENTIFIER    

cpqRackComponent 1.3.6.1.4.1.232.22.2
OBJECT IDENTIFIER    

cpqRackSysObjID 1.3.6.1.4.1.232.22.3
OBJECT IDENTIFIER    

cpqRackInterface 1.3.6.1.4.1.232.22.2.1
OBJECT IDENTIFIER    

cpqRackAsset 1.3.6.1.4.1.232.22.2.2
OBJECT IDENTIFIER    

cpqRackEnclosure 1.3.6.1.4.1.232.22.2.3
OBJECT IDENTIFIER    

cpqRackServer 1.3.6.1.4.1.232.22.2.4
OBJECT IDENTIFIER    

cpqRackPower 1.3.6.1.4.1.232.22.2.5
OBJECT IDENTIFIER    

cpqRackNetwork 1.3.6.1.4.1.232.22.2.6
OBJECT IDENTIFIER    

cpqRackOsCommon 1.3.6.1.4.1.232.22.2.1.4
OBJECT IDENTIFIER    

cpqRackCommonEnclosure 1.3.6.1.4.1.232.22.2.3.1
OBJECT IDENTIFIER    

cpqRackServerEnclosure 1.3.6.1.4.1.232.22.2.3.2
OBJECT IDENTIFIER    

cpqRackPowerEnclosure 1.3.6.1.4.1.232.22.2.3.3
OBJECT IDENTIFIER    

cpqRackServerBlade 1.3.6.1.4.1.232.22.2.4.1
OBJECT IDENTIFIER    

cpqRackServerNetworking 1.3.6.1.4.1.232.22.2.4.2
OBJECT IDENTIFIER    

cpqRackServerTempSensor 1.3.6.1.4.1.232.22.2.4.3
OBJECT IDENTIFIER    

cpqRackPowerSupply 1.3.6.1.4.1.232.22.2.5.1
OBJECT IDENTIFIER    

cpqRackNetConnector 1.3.6.1.4.1.232.22.2.6.1
OBJECT IDENTIFIER    

cpqRackMibRevMajor 1.3.6.1.4.1.232.22.1.1
The major revision level of the MIB. A change in the major revision level represents a major change in the architecture of the MIB. A change in the major revision level may indicate a significant change in the information supported and/or the meaning of the supported information, correct interpretation of data may require a MIB document with the same major revision level.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..65535  

cpqRackMibRevMinor 1.3.6.1.4.1.232.22.1.2
The minor revision level of the MIB. A change in the minor revision level may represent some minor additional support, no changes to any pre-existing information has occurred.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..65535  

cpqRackMibCondition 1.3.6.1.4.1.232.22.1.3
The overall condition. This object represents the overall status of the rack information represented by this MIB.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(1), ok(2), degraded(3), failed(4)  

cpqRackOsCommonPollFreq 1.3.6.1.4.1.232.22.2.1.4.1
The Management Agent's polling frequency. The frequency, in seconds, at which the Agent requests information from the device driver. A frequency of zero (0) indicates that the Insight Agent retrieves the information upon request of a management station, it does not poll the device driver at a specific interval. If the poll frequency is zero (0) all attempts to write to this object will fail. If the poll frequency is non-zero, setting this value will change the polling frequency of the Insight Agent. Setting the poll frequency to zero (0) will always fail, an agent may also choose to fail any request to change the poll frequency to a value that would severely impact system performance.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..65535  

cpqRackAssetTable 1.3.6.1.4.1.232.22.2.2.1
A table of rack asset information.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    CpqRackAssetEntry

cpqRackAssetEntry 1.3.6.1.4.1.232.22.2.2.1.1
A rack asset description.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  CpqRackAssetEntry  

cpqRackAssetIndex 1.3.6.1.4.1.232.22.2.2.1.1.1
A number that uniquely specifies this rack table entry.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cpqRackName 1.3.6.1.4.1.232.22.2.2.1.1.2
The customer changeable identifier used to identify the entire rack. The string will be empty if the system does not report this function.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..64)  

cpqRackUid 1.3.6.1.4.1.232.22.2.2.1.1.3
The rack unique identifier. The string will be empty if the rack does not report the UID or if it could not be determined.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..64)  

cpqRackSerialNum 1.3.6.1.4.1.232.22.2.2.1.1.4
The rack serial number. The string will be empty if the rack does not report the serial number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..64)  

cpqRackTrapSequenceNum 1.3.6.1.4.1.232.22.2.2.1.1.5
The trap sequence number for rack traps. This is used by the management application trap processing. This will be -1 if the rack does not report the information or it could not be determined.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cpqRackHeight 1.3.6.1.4.1.232.22.2.2.1.1.6
The internal height dimension of the useable rack space expressed in millimeters. This will be -1 if the rack does not report the information or it could not be determined.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cpqRackWidth 1.3.6.1.4.1.232.22.2.2.1.1.7
The internal width dimension of the useable rack space expressed in millimeters. This will be -1 if the rack does not report the information or it could not be determined.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cpqRackDepth 1.3.6.1.4.1.232.22.2.2.1.1.8
The internal depth dimension of the useable rack space expressed in millimeters. This will be -1 if the rack does not report the information or it could not be determined.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cpqRackCommonEnclosureTable 1.3.6.1.4.1.232.22.2.3.1.1
A table of rack enclosure information.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    CpqRackCommonEnclosureEntry

cpqRackCommonEnclosureEntry 1.3.6.1.4.1.232.22.2.3.1.1.1
A rack enclosure description.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  CpqRackCommonEnclosureEntry  

cpqRackCommonEnclosureRack 1.3.6.1.4.1.232.22.2.3.1.1.1.1
A number that uniquely specifies this rack.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cpqRackCommonEnclosureIndex 1.3.6.1.4.1.232.22.2.3.1.1.1.2
A number that uniquely specifies this enclosure in the rack.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cpqRackCommonEnclosureModel 1.3.6.1.4.1.232.22.2.3.1.1.1.3
The model name of the enclosure. The string will be empty if the enclosure does not report the model information.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..64)  

cpqRackCommonEnclosureAssetTag 1.3.6.1.4.1.232.22.2.3.1.1.1.4
The customer changeable asset identifier of the enclosure. The string will be empty if the system does not report this function or if the asset tag has not been set.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..64)  

cpqRackCommonEnclosurePartNumber 1.3.6.1.4.1.232.22.2.3.1.1.1.5
The part number of the enclosure. The string will be empty if the enclosure does not report this function.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..64)  

cpqRackCommonEnclosureSparePartNumber 1.3.6.1.4.1.232.22.2.3.1.1.1.6
The spare part number of the enclosure. The string will be empty if the enclosure does not report this function.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..64)  

cpqRackCommonEnclosureSerialNum 1.3.6.1.4.1.232.22.2.3.1.1.1.7
The serial number of the enclosure. The string will be empty if the enclosure does not report the serial number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..64)  

cpqRackCommonEnclosureFWRev 1.3.6.1.4.1.232.22.2.3.1.1.1.8
The firmware revision of the enclosure. The string will be empty if the enclosure does not report the firmware revision or does not contain firmware.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..64)  

cpqRackCommonEnclosureName 1.3.6.1.4.1.232.22.2.3.1.1.1.9
The name of the enclosure. The string will be empty if the enclosure does not report the name or it could not be determined.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..64)  

cpqRackCommonEnclosureNeighborNamePrev 1.3.6.1.4.1.232.22.2.3.1.1.1.10
The name of the enclosure immediately preceding or above this enclosure. The string will be empty if the neighbor enclosure name could not be determined or there is no enclosure preceding this one.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..64)  

cpqRackCommonEnclosureNeighborNameNext 1.3.6.1.4.1.232.22.2.3.1.1.1.11
The name of the enclosure immediately following or below this enclosure. The string will be empty if the neighbor enclosure name could not be determined or there is no enclosure following this one.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..64)  

cpqRackCommonEnclosureHeight 1.3.6.1.4.1.232.22.2.3.1.1.1.12
The height dimension of the rack space taken by the enclosure expressed in millimeters. This will be -1 if the rack does not report the information or it could not be determined.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cpqRackCommonEnclosureWidth 1.3.6.1.4.1.232.22.2.3.1.1.1.13
The width dimension of the rack space taken by the enclosure expressed in millimeters. This will be -1 if the rack does not report the information or it could not be determined.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cpqRackCommonEnclosureDepth 1.3.6.1.4.1.232.22.2.3.1.1.1.14
The depth dimension of the rack space taken by the enclosure expressed in millimeters. This will be -1 if the rack does not report the information or it could not be determined.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cpqRackCommonEnclosureTrapSequenceNum 1.3.6.1.4.1.232.22.2.3.1.1.1.15
The trap sequence number for the enclosure. This is used by the management application trap processing. This will be -1 if the rack does not report the information or it could not be determined.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cpqRackCommonEnclosureCondition 1.3.6.1.4.1.232.22.2.3.1.1.1.16
The overall condition of the enclosure. This is the aggregate of the temperature sensors, fans, and fuses within the enclosure. This value will be one of the following: other(1) No temperature sensors, fans, or fuses in the enclosure or the state could no be determined. ok(2) All temperature sensors, fans, and fuses are within the normal operating range. degraded(3) One or more temperature sensors, fans, or fuses are outside of the normal operating range. None are failed. failed(4) The temperature sensor exceeded the critical threshold value, a required fan has failed, or a fuse has been tripped. The system will automatically shutdown if the failed(4) condition results, so it is unlikely that this value will ever be returned by the agent.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(1), ok(2), degraded(3), failed(4)  

cpqRackCommonEnclosureHasServerBlades 1.3.6.1.4.1.232.22.2.3.1.1.1.17
The enclosure can contain server blades. This will be true(2) is the enclosure can house server blades. The cpqRackServerEnclosureTable will contain server enclosure specific information. Match the cpqRackCommonEnclosureSerialNum in this table to the serial number in the cpqRackServerEnclosureTable to get complete information on the server enclosure.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER false(1), true(2)  

cpqRackCommonEnclosureHasPowerSupplies 1.3.6.1.4.1.232.22.2.3.1.1.1.18
The enclosure can contain power supplies. This will be true(2) is the enclosure can house power supplies. The cpqRackEnclosurePowerTable will contain power enclosure specific information. Match the cpqRackCommonEnclosureSerialNum in this table to the serial number in the cpqRackEnclosurePowerTable to get complete information on the power enclosure.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER false(1), true(2)  

cpqRackCommonEnclosureHasNetConnectors 1.3.6.1.4.1.232.22.2.3.1.1.1.19
The enclosure contains network connectivity. This will be true(2) is the enclosure contains network connectivity. The cpqRackCommonEnclosureNetConnectorTable will contain network connectivity specific information. Match the cpqRackCommonEnclosureSerialNum in this table to the serial number in the cpqRackCommonEnclosureNetConnectorTable to get complete information on the network connector enclosure.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER false(1), true(2)  

cpqRackCommonEnclosureHasTempSensors 1.3.6.1.4.1.232.22.2.3.1.1.1.20
The enclosure contains temperature sensors. This will be true(2) is the enclosure contains temperature sensors. The cpqRackCommonEnclosureTempTable will contain temperature sensor specific information. Match the cpqRackCommonEnclosureSerialNum in this table to the serial number in the cpqRackCommonEnclosureTempTable to get complete information on the enclosure.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER false(1), true(2)  

cpqRackCommonEnclosureHasFans 1.3.6.1.4.1.232.22.2.3.1.1.1.21
The enclosure contains fans. This will be true(2) is the enclosure contains fans. The cpqRackCommonEnclosureFanTable will contain the fan specific information. Match the cpqRackCommonEnclosureSerialNum in this table to the serial number in the cpqRackCommonEnclosureFanTable to get complete information on the enclosure.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER false(1), true(2)  

cpqRackCommonEnclosureHasFuses 1.3.6.1.4.1.232.22.2.3.1.1.1.22
The enclosure contains fuses. This will be true(2) is the enclosure contains fuses. The cpqRackCommonEnclosureFuseTable will contain the fuse specific information. Match the cpqRackCommonEnclosureSerialNum in this table to the serial number in the cpqRackCommonEnclosureFuseTable to get complete information on the enclosure.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER false(1), true(2)  

cpqRackCommonEnclosureMgmtUID 1.3.6.1.4.1.232.22.2.3.1.1.1.23
The Unit Identifier LED. This value will be one of the following: other(1) The state of the LED could not be determined. Setting the LED state is not allowed. none(2) The LED is not present. Setting LED state is not allowed. ledOn(3) The LED is present and ON. The LED can be turned off by setting the cpqRackCommonEnclosureMgmtUID to ledOff(4). ledOff(4) The LED is present and OFF. The LED can be turned on by setting the cpqRackCommonEnclosureMgmtUID to ledOn(3).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER other(1), none(2), ledOn(3), ledOff(4)  

cpqRackCommonEnclosureSerialNumPrev 1.3.6.1.4.1.232.22.2.3.1.1.1.24
The serial number of the enclosure immediately preceding or above this enclosure. The string will be empty if the neighbor enclosure serial number could not be determined or there is no enclosure preceding this one.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..64)  

cpqRackCommonEnclosureSerialNumNext 1.3.6.1.4.1.232.22.2.3.1.1.1.25
The serial number of the enclosure immediately following or below this enclosure. The string will be empty if the neighbor enclosure serial number could not be determined or there is no enclosure following this one.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..64)  

cpqRackCommonEnclosureAddress 1.3.6.1.4.1.232.22.2.3.1.1.1.26
The unique address of the enclosure within the rack. This will be -1 if the rack does not report the information or it could not be determined.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cpqRackCommonEnclosureProductId 1.3.6.1.4.1.232.22.2.3.1.1.1.27
The product id string of the enclosure. The string will be empty if the enclosure does not report the product id string.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..64)  

cpqRackCommonEnclosureProductIdPrev 1.3.6.1.4.1.232.22.2.3.1.1.1.28
The product id string of the enclosure immediately preceding or above this enclosure. The string will be empty if the enclosure does not report the product id string.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..64)  

cpqRackCommonEnclosureProductIdNext 1.3.6.1.4.1.232.22.2.3.1.1.1.29
The product id string of the enclosure immediately following or below this enclosure. The string will be empty if the enclosure does not report the product id string.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..64)  

cpqRackCommonEnclosureUUID 1.3.6.1.4.1.232.22.2.3.1.1.1.30
The universal unique identifier string of the enclosure. The string will be empty if the enclosure does not report the UUID string.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..64)  

cpqRackCommonEnclosureUUIDPrev 1.3.6.1.4.1.232.22.2.3.1.1.1.31
The universal unique identifier string of the enclosure immediately preceding or above this enclosure. The string will be empty if the enclosure does not report the UUID string or if there is no preceding enclosure.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..64)  

cpqRackCommonEnclosureUUIDNext 1.3.6.1.4.1.232.22.2.3.1.1.1.32
The universal unique identifier string of the enclosure immediately following or below this enclosure. The string will be empty if the enclosure does not report the UUID string or if there is no following enclosure.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..64)  

cpqRackCommonEnclosureHasManagers 1.3.6.1.4.1.232.22.2.3.1.1.1.33
The enclosure contains managers. This will be true(2) is the enclosure contains managers. The cpqRackCommonEnclosureManagerTable will contain the manager specific information. Match the cpqRackCommonEnclosureSerialNum in this table to the serial number in the cpqRackCommonEnclosureManagerTable to get complete information on the enclosure.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER false(1), true(2)  

cpqRackCommonEnclosureTempTable 1.3.6.1.4.1.232.22.2.3.1.2
A table of rack enclosure temperature sensor information.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    CpqRackCommonEnclosureTempEntry

cpqRackCommonEnclosureTempEntry 1.3.6.1.4.1.232.22.2.3.1.2.1
A rack enclosure temperature sensor description.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  CpqRackCommonEnclosureTempEntry  

cpqRackCommonEnclosureTempRack 1.3.6.1.4.1.232.22.2.3.1.2.1.1
A number that uniquely specifies this rack.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cpqRackCommonEnclosureTempChassis 1.3.6.1.4.1.232.22.2.3.1.2.1.2
A number that uniquely specifies this enclosure in the rack.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cpqRackCommonEnclosureTempSensorIndex 1.3.6.1.4.1.232.22.2.3.1.2.1.3
A number that uniquely specifies this temperature sensor within this enclosure in the rack.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cpqRackCommonEnclosureTempSensorEnclosureName 1.3.6.1.4.1.232.22.2.3.1.2.1.4
The name of the enclosure. The string will be empty if the enclosure does not report the name or it could not be determined.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..64)  

cpqRackCommonEnclosureTempLocation 1.3.6.1.4.1.232.22.2.3.1.2.1.5
The location description of the temperature sensor within the enclosure. The string will be empty if the location could not be determined.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..64)  

cpqRackCommonEnclosureTempCurrent 1.3.6.1.4.1.232.22.2.3.1.2.1.6
This is the current temperature sensor reading in degrees celsius. If this value cannot be determined by software, then a value of -1 will be returned.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cpqRackCommonEnclosureTempThreshold 1.3.6.1.4.1.232.22.2.3.1.2.1.7
This is the threshold temperature sensor setting in degrees celsius. This is the temperature in which the sensor will be considered to be in a tripped state this causing some action to occur depending on the type of the sensor. The action of temperature sensor threshold will be indicated by the cpqRackCommonEnclosureTempType item. If the type is blowout(5), then the temperature sensor will cause the fans to speed up. If the type is caution(9), then the temperature sensor is in a degraded state. If the type is critical(15), then the enclosure will be considered as in a failed state. If this value cannot be determined by software, then a value of -1 will be returned.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cpqRackCommonEnclosureTempCondition 1.3.6.1.4.1.232.22.2.3.1.2.1.8
The Temperature sensor condition. This value will be one of the following: other(1) Temperature could not be determined. ok(2) The temperature sensor is within the normal operating range. degraded(3) The temperature sensor is outside of the normal operating range. failed(4) The temperature sensor detects a condition that could possibly damage the system. The system will automatically shutdown if the failed(4) condition results, so it is unlikely that this value will ever be returned by the agent.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(1), ok(2), degraded(3), failed(4)  

cpqRackCommonEnclosureTempType 1.3.6.1.4.1.232.22.2.3.1.2.1.9
This specifies the type of this instance of temperature sensor. This value will be one of the following: other(1) Temperature threshold type could not be determined. blowout(5) If a blowout(5) temperature sensor reaches its threshold, the fan or fans in the area of the temperature sensor will increase in speed in an attempt to reduce the temperature before a caution or critical threshold is reached. caution(9) If a caution(9) temperature sensor reaches its threshold, the cpqRackCommonEnclosureTempCondition will be set to degraded(3) and the system will either continue or shutdown depending on the user preferences. critical(15) If a critical(15) temperature sensor reaches its threshold, the cpqHeTemperatureCondition will be set to failed(4) and the system will shutdown.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(1), blowout(5), caution(9), critical(15)  

cpqRackCommonEnclosureTempSensorEnclosureSerialNum 1.3.6.1.4.1.232.22.2.3.1.2.1.10
The serial number of the enclosure containing this temperature sensor. The string will be empty if the enclosure does not report the serial number or it could not be determined.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..64)  

cpqRackCommonEnclosureFanTable 1.3.6.1.4.1.232.22.2.3.1.3
A table of rack enclosure fan information.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    CpqRackCommonEnclosureFanEntry

cpqRackCommonEnclosureFanEntry 1.3.6.1.4.1.232.22.2.3.1.3.1
A rack enclosure fan description.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  CpqRackCommonEnclosureFanEntry  

cpqRackCommonEnclosureFanRack 1.3.6.1.4.1.232.22.2.3.1.3.1.1
A number that uniquely specifies this rack.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cpqRackCommonEnclosureFanChassis 1.3.6.1.4.1.232.22.2.3.1.3.1.2
A number that uniquely specifies this enclosure in the rack.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cpqRackCommonEnclosureFanIndex 1.3.6.1.4.1.232.22.2.3.1.3.1.3
A number that uniquely specifies this fan within this enclosure in the rack.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cpqRackCommonEnclosureFanEnclosureName 1.3.6.1.4.1.232.22.2.3.1.3.1.4
The name of the enclosure. The string will be empty if the enclosure does not report the name or it could not be determined.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..64)  

cpqRackCommonEnclosureFanLocation 1.3.6.1.4.1.232.22.2.3.1.3.1.5
The location description of the fan within the enclosure. The string will be empty if the location could not be determined.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..64)  

cpqRackCommonEnclosureFanPartNumber 1.3.6.1.4.1.232.22.2.3.1.3.1.6
The part number of the enclosure fan. The string will be empty if the part number could not be determined.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..64)  

cpqRackCommonEnclosureFanSparePartNumber 1.3.6.1.4.1.232.22.2.3.1.3.1.7
The spare part number of the enclosure fan. The string will be empty if the part number could not be determined.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..64)  

cpqRackCommonEnclosureFanPresent 1.3.6.1.4.1.232.22.2.3.1.3.1.8
This specifies if the fan described is present in the system.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(1), absent(2), present(3)  

cpqRackCommonEnclosureFanRedundant 1.3.6.1.4.1.232.22.2.3.1.3.1.9
This specifies if the fan is in a redundant configuration.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(1), notRedundant(2), redundant(3)  

cpqRackCommonEnclosureFanRedundantGroupId 1.3.6.1.4.1.232.22.2.3.1.3.1.10
This specifies the group number for redundant fans within this enclosure.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cpqRackCommonEnclosureFanCondition 1.3.6.1.4.1.232.22.2.3.1.3.1.11
The condition of the fan. This value will be one of the following: other(1) Fan status detection is not supported. ok(2) The fan is operating properly. degraded(2) A redundant fan is not operating properly. failed(4) A non-redundant fan is not operating properly.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(1), ok(2), degraded(3), failed(4)  

cpqRackCommonEnclosureFanEnclosureSerialNum 1.3.6.1.4.1.232.22.2.3.1.3.1.12
The serial number of the enclosure containing the fan. The string will be empty if the enclosure does not report the serial number or it could not be determined.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..64)  

cpqRackCommonEnclosureFuseTable 1.3.6.1.4.1.232.22.2.3.1.4
A table of rack enclosure fuse information.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    CpqRackCommonEnclosureFuseEntry

cpqRackCommonEnclosureFuseEntry 1.3.6.1.4.1.232.22.2.3.1.4.1
A rack enclosure fuse description.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  CpqRackCommonEnclosureFuseEntry  

cpqRackCommonEnclosureFuseRack 1.3.6.1.4.1.232.22.2.3.1.4.1.1
A number that uniquely specifies this rack.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cpqRackCommonEnclosureFuseChassis 1.3.6.1.4.1.232.22.2.3.1.4.1.2
A number that uniquely specifies this enclosure in the rack.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cpqRackCommonEnclosureFuseIndex 1.3.6.1.4.1.232.22.2.3.1.4.1.3
A number that uniquely specifies the fuse within this enclosure.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cpqRackCommonEnclosureFuseEnclosureName 1.3.6.1.4.1.232.22.2.3.1.4.1.4
The name of the enclosure. The string will be empty if the enclosure does not report the name or it could not be determined.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..64)  

cpqRackCommonEnclosureFuseLocation 1.3.6.1.4.1.232.22.2.3.1.4.1.5
The location description of the fuse within the enclosure. The string will be empty if the location could not be determined.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..64)  

cpqRackCommonEnclosureFusePresent 1.3.6.1.4.1.232.22.2.3.1.4.1.6
This specifies if the fuse described is present in the system.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(1), absent(2), present(3)  

cpqRackCommonEnclosureFuseCondition 1.3.6.1.4.1.232.22.2.3.1.4.1.7
The condition of the fuse. This value will be one of the following: other(1) Fuse status detection is not supported. ok(2) The fuse is operating properly. failed(4) A fuse has been tripped or is not operating properly.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(1), ok(2), failed(4)  

cpqRackCommonEnclosureFruTable 1.3.6.1.4.1.232.22.2.3.1.5
A table of rack enclosure field replaceable units information.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    CpqRackCommonEnclosureFruEntry

cpqRackCommonEnclosureFruEntry 1.3.6.1.4.1.232.22.2.3.1.5.1
A rack enclosure field replaceable unit description.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  CpqRackCommonEnclosureFruEntry  

cpqRackCommonEnclosureFruRack 1.3.6.1.4.1.232.22.2.3.1.5.1.1
A number that uniquely specifies this rack.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cpqRackCommonEnclosureFruChassis 1.3.6.1.4.1.232.22.2.3.1.5.1.2
A number that uniquely specifies this enclosure in the rack.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cpqRackCommonEnclosureFruIndex 1.3.6.1.4.1.232.22.2.3.1.5.1.3
A number that uniquely specifies the FRU within this enclosure.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cpqRackCommonEnclosureFruEnclosureName 1.3.6.1.4.1.232.22.2.3.1.5.1.4
The name of the enclosure. The string will be empty if the enclosure does not report the name or it could not be determined.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..64)  

cpqRackCommonEnclosureFruDescription 1.3.6.1.4.1.232.22.2.3.1.5.1.5
A description of the FRU component. The string will be empty if the enclosure does not report the description information.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..64)  

cpqRackCommonEnclosureFruLocation 1.3.6.1.4.1.232.22.2.3.1.5.1.6
The location description of the FRU within the enclosure. The string will be empty if the location could not be determined.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..64)  

cpqRackCommonEnclosureFruAssemblyPartNumber 1.3.6.1.4.1.232.22.2.3.1.5.1.7
The assembly part number of the FRU within the enclosure. The string will be empty if the enclosure does not report this information.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..64)  

cpqRackCommonEnclosureFruSparePartNumber 1.3.6.1.4.1.232.22.2.3.1.5.1.8
The spare part number of the FRU within the enclosure. The string will be empty if the enclosure does not report this information.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..64)  

cpqRackCommonEnclosureFruAutoRev 1.3.6.1.4.1.232.22.2.3.1.5.1.9
The auto revision number of the FRU within the enclosure. The string will be empty if the enclosure does not report this information.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..64)  

cpqRackCommonEnclosureFruSerialNum 1.3.6.1.4.1.232.22.2.3.1.5.1.10
The serial number of the FRU within the enclosure. The string will be empty if the enclosure does not report the serial number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..64)  

cpqRackCommonEnclosureManagerTable 1.3.6.1.4.1.232.22.2.3.1.6
A table of rack enclosure manager information.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    CpqRackCommonEnclosureManagerEntry

cpqRackCommonEnclosureManagerEntry 1.3.6.1.4.1.232.22.2.3.1.6.1
A rack enclosure manager description.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  CpqRackCommonEnclosureManagerEntry  

cpqRackCommonEnclosureManagerRack 1.3.6.1.4.1.232.22.2.3.1.6.1.1
A number that uniquely specifies this rack.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cpqRackCommonEnclosureManagerChassis 1.3.6.1.4.1.232.22.2.3.1.6.1.2
A number that uniquely specifies this enclosure in the rack.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cpqRackCommonEnclosureManagerIndex 1.3.6.1.4.1.232.22.2.3.1.6.1.3
A number that uniquely specifies this manager within this enclosure in the rack.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cpqRackCommonEnclosureManagerEnclosureName 1.3.6.1.4.1.232.22.2.3.1.6.1.4
The name of the enclosure. The string will be empty if the enclosure does not report the name or it could not be determined.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..64)  

cpqRackCommonEnclosureManagerLocation 1.3.6.1.4.1.232.22.2.3.1.6.1.5
The location description of the manager within the enclosure. The string will be empty if the location could not be determined.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..64)  

cpqRackCommonEnclosureManagerPartNumber 1.3.6.1.4.1.232.22.2.3.1.6.1.6
The part number of the enclosure manager. The string will be empty if the part number could not be determined.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..64)  

cpqRackCommonEnclosureManagerSparePartNumber 1.3.6.1.4.1.232.22.2.3.1.6.1.7
The spare part number of the enclosure manager. The string will be empty if the part number could not be determined.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..64)  

cpqRackCommonEnclosureManagerSerialNum 1.3.6.1.4.1.232.22.2.3.1.6.1.8
The serial number of the enclosure manager. The string will be empty if the enclosure does not report the serial number or it could not be determined.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..64)  

cpqRackCommonEnclosureManagerRole 1.3.6.1.4.1.232.22.2.3.1.6.1.9
This specifies the current role of the manager.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER standby(1), active(2)  

cpqRackCommonEnclosureManagerPresent 1.3.6.1.4.1.232.22.2.3.1.6.1.10
This specifies if the manager described is present in the system.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(1), absent(2), present(3)  

cpqRackCommonEnclosureManagerRedundant 1.3.6.1.4.1.232.22.2.3.1.6.1.11
This specifies if the manager is in a redundant configuration.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(1), notRedundant(2), redundant(3)  

cpqRackCommonEnclosureManagerCondition 1.3.6.1.4.1.232.22.2.3.1.6.1.12
The condition of the manager. This value will be one of the following: other(1) Manager status detection is not supported. ok(2) The manager is operating properly. degraded(2) A redundant manager is not operating properly. failed(4) A non-redundant manager is not operating properly.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(1), ok(2), degraded(3), failed(4)  

cpqRackCommonEnclosureManagerEnclosureSerialNum 1.3.6.1.4.1.232.22.2.3.1.6.1.13
The serial number of the enclosure containing the manager. The string will be empty if the enclosure does not report the serial number or it could not be determined.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..64)  

cpqRackCommonEnclosureManagerUUID 1.3.6.1.4.1.232.22.2.3.1.6.1.14
The universal unique identifier string of the manager. The string will be empty if the enclosure does not report the UUID string.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..64)  

cpqRackCommonEnclosureManagerFWRev 1.3.6.1.4.1.232.22.2.3.1.6.1.15
The firmware revision of the enclosure manager. The string will be empty if the enclosure does not report the firmware revision or does not contain firmware.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..64)  

cpqRackServerEnclosureTable 1.3.6.1.4.1.232.22.2.3.2.1
A table of rack enclosure information for servers.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    CpqRackServerEnclosureEntry

cpqRackServerEnclosureEntry 1.3.6.1.4.1.232.22.2.3.2.1.1
A server enclosure description.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  CpqRackServerEnclosureEntry  

cpqRackServerEnclosureRack 1.3.6.1.4.1.232.22.2.3.2.1.1.1
A number that uniquely specifies this rack.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cpqRackServerEnclosureIndex 1.3.6.1.4.1.232.22.2.3.2.1.1.2
A number that uniquely specifies this server enclosure in the rack.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cpqRackServerEnclosureName 1.3.6.1.4.1.232.22.2.3.2.1.1.3
The name of the server enclosure. The string will be empty if the enclosure does not report the name or it could not be determined.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..64)  

cpqRackServerEnclosureMaxNumBlades 1.3.6.1.4.1.232.22.2.3.2.1.1.4
The maximum number of server blades the enclosure can contain. The string will be empty if the enclosure does not report the name or it could not be determined.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cpqRackServerEnclosureMaxNumBladesX 1.3.6.1.4.1.232.22.2.3.2.1.1.5
The maximum number of server blades in x-direction (from left to right) the enclosure can contain.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cpqRackServerEnclosureMaxNumBladesY 1.3.6.1.4.1.232.22.2.3.2.1.1.6
The maximum number of server blades in y-direction (from top to bottom) the enclosure can contain.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cpqRackPowerEnclosureTable 1.3.6.1.4.1.232.22.2.3.3.1
A table of rack power enclosure information.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    CpqRackPowerEnclosureEntry

cpqRackPowerEnclosureEntry 1.3.6.1.4.1.232.22.2.3.3.1.1
A rack power enclosure description.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  CpqRackPowerEnclosureEntry  

cpqRackPowerEnclosureRack 1.3.6.1.4.1.232.22.2.3.3.1.1.1
A number that uniquely specifies this rack.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cpqRackPowerEnclosureIndex 1.3.6.1.4.1.232.22.2.3.3.1.1.2
A number that uniquely specifies this power enclosure in the rack.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cpqRackPowerEnclosureName 1.3.6.1.4.1.232.22.2.3.3.1.1.3
The name of the power enclosure. The string will be empty if the enclosure does not report the name or it could not be determined.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..64)  

cpqRackPowerEnclosureMgmtBoardSerialNum 1.3.6.1.4.1.232.22.2.3.3.1.1.4
The serial number of the enclosure. The string will be empty if the enclosure does not report the serial number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..64)  

cpqRackPowerEnclosureRedundant 1.3.6.1.4.1.232.22.2.3.3.1.1.5
This indicates if the power supply enclosure is in a redundant state.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(1), notRedundant(2), redundant(3)  

cpqRackPowerEnclosureLoadBalanced 1.3.6.1.4.1.232.22.2.3.3.1.1.6
This indicates if the power supply enclosure is in a load balanced state.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(1), notLoadBalanced(2), loadBalanced(3)  

cpqRackPowerEnclosureInputPwrType 1.3.6.1.4.1.232.22.2.3.3.1.1.7
This indicates type of input facility power.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(1), singlePhase(2), threePhase(3), directCurrent(4)  

cpqRackPowerEnclosurePwrFeedMax 1.3.6.1.4.1.232.22.2.3.3.1.1.8
This is the maximum facility power in watts. The maximum facility power being fed to this power enclosure. The value will be -1 if the power enclosure does not report the value or if the value is not known.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cpqRackPowerEnclosureCondition 1.3.6.1.4.1.232.22.2.3.3.1.1.9
This indicates current condition of the power enclosure. other(1) The power enclosure condition could not be determined. ok(2) The power enclosure is operating normally. degraded(3) The power enclosure is in a degraded state. The power subsystem may not be load balanced or may have lost redundancy.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(1), ok(2), degraded(3)  

cpqRackPowerEnclosureBladeAutopoweron 1.3.6.1.4.1.232.22.2.3.3.1.1.10
This indicates current condition of the power enclosure. other(1) The blade auto power on feature could not be determined. disabled(2) The enclosure will not automatically power on a blade when inserted. enabled(3) The enclosure will automatically power on a blade when inserted.
Status: optional Access: read-write
OBJECT-TYPE    
  INTEGER other(1), disabled(2), enabled(3)  

cpqRackLastEAEEvent 1.3.6.1.4.1.232.22.2.3.2.2
Data for the last EAE event.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..512)  

cpqRackServerBladeTable 1.3.6.1.4.1.232.22.2.4.1.1
A table of rack server blade information.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    CpqRackServerBladeEntry

cpqRackServerBladeEntry 1.3.6.1.4.1.232.22.2.4.1.1.1
A rack server blade description.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  CpqRackServerBladeEntry  

cpqRackServerBladeRack 1.3.6.1.4.1.232.22.2.4.1.1.1.1
A number that uniquely specifies this rack.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cpqRackServerBladeChassis 1.3.6.1.4.1.232.22.2.4.1.1.1.2
A number that uniquely specifies this enclosure in the rack.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cpqRackServerBladeIndex 1.3.6.1.4.1.232.22.2.4.1.1.1.3
A number that uniquely specifies this server blade within the enclosure.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cpqRackServerBladeName 1.3.6.1.4.1.232.22.2.4.1.1.1.4
The name of the server blade. The string will be empty if it could not be determined.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..64)  

cpqRackServerBladeEnclosureName 1.3.6.1.4.1.232.22.2.4.1.1.1.5
The name of the enclosure which contains the blade. The string will be empty if the enclosure does not report the name or it could not be determined.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..64)  

cpqRackServerBladePartNumber 1.3.6.1.4.1.232.22.2.4.1.1.1.6
The part number of the server blade. The string will be empty if the part number could not be determined.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..64)  

cpqRackServerBladeSparePartNumber 1.3.6.1.4.1.232.22.2.4.1.1.1.7
The spare part number of the server blade. The string will be empty if the part number could not be determined.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..64)  

cpqRackServerBladePosition 1.3.6.1.4.1.232.22.2.4.1.1.1.8
The position or slot number of the server blade within the server enclosure. This will be -1 if the server enclosure does not report the information or it could not be determined.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cpqRackServerBladeHeight 1.3.6.1.4.1.232.22.2.4.1.1.1.9
The height dimension of the rack space taken by the server blade expressed in millimeters. This will be -1 if the rack does not report the information or it could not be determined.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cpqRackServerBladeWidth 1.3.6.1.4.1.232.22.2.4.1.1.1.10
The width dimension of the rack space taken by the server blade expressed in millimeters. This will be -1 if the rack does not report the information or it could not be determined.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cpqRackServerBladeDepth 1.3.6.1.4.1.232.22.2.4.1.1.1.11
The depth dimension of the rack space taken by the server blade expressed in millimeters. This will be -1 if the rack does not report the information or it could not be determined.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cpqRackServerBladePresent 1.3.6.1.4.1.232.22.2.4.1.1.1.12
This specifies if the server blade described is present in the enclosure.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(1), absent(2), present(3)  

cpqRackServerBladeHasFuses 1.3.6.1.4.1.232.22.2.4.1.1.1.13
The server blade contains fuses. This will be true(2) is the server blade contains fuses. The cpqRackCommonEnclosureFuseTable will contain the fuse specific information. Match the cpqRackServerBladeEnclosureSerialNum in this table to the serial number in the cpqRackCommonEnclosureFanTable to get complete information on the fuses.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER false(1), true(2)  

cpqRackServerBladeEnclosureSerialNum 1.3.6.1.4.1.232.22.2.4.1.1.1.14
The serial number of the enclosure which contains the blade. The string will be empty if the enclosure does not report the serial number or it could not be determined.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..64)  

cpqRackServerBladeSlotsUsed 1.3.6.1.4.1.232.22.2.4.1.1.1.15
The number of slot positions occupied by this server blade. This is used to indicate a server blade which may obscure an adjacent blade slot. This will be -1 if the rack does not report the information or it could not be determined.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cpqRackServerBladeSerialNum 1.3.6.1.4.1.232.22.2.4.1.1.1.16
The serial number of the server blade. The string will be empty if the system does not report the serial number function.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..64)  

cpqRackServerBladeProductId 1.3.6.1.4.1.232.22.2.4.1.1.1.17
The product id string of the server blade. The string will be empty if the system does not report the product id function.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..64)  

cpqRackServerBladeUid 1.3.6.1.4.1.232.22.2.4.1.1.1.18
The server blade unique identifier (UUID). The string will be empty if the blade does not report the UUID or if it could not be determined.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..64)  

cpqRackServerBladeSlotsUsedX 1.3.6.1.4.1.232.22.2.4.1.1.1.19
The number of slot positions in x-direction (from left to right) occupied by this server blade. This is used to indicate a server blade which may obscure an adjacent blade slot. This will be -1 if the rack does not report the information or it could not be determined.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cpqRackServerBladeSlotsUsedY 1.3.6.1.4.1.232.22.2.4.1.1.1.20
The number of slot positions in y-direction (from top to bottom) occupied by this server blade. This is used to indicate a server blade which may obscure an adjacent blade slot. This will be -1 if the rack does not report the information or it could not be determined.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cpqRackServerBladeStatus 1.3.6.1.4.1.232.22.2.4.1.1.1.21
The health status of the blade. This will be other(1) if the rack does not report the information or if it could not be determined.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER other(1), ok(2), degraded(3), failed(4)  

cpqRackServerBladeFaultMajor 1.3.6.1.4.1.232.22.2.4.1.1.1.22
The major fault code of the blade fault reported by the enclosure manager. This will be -1 if the rack does not report the information or if it could not be determined.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER  

cpqRackServerBladeFaultMinor 1.3.6.1.4.1.232.22.2.4.1.1.1.23
The minor fault code of the blade fault reported by the enclosure manager. This will be -1 if the rack does not report the information or if it could not be determined.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER  

cpqRackServerBladeFaultDiagnosticString 1.3.6.1.4.1.232.22.2.4.1.1.1.24
The server blade fault diagnostic string. This will contain a probable cause and potential diagnostic action to be taken to remedy the fault condition. The string will be empty if the blade does not report the diagnostic string or if it could not be determined.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..128)  

cpqRackServerBladePowered 1.3.6.1.4.1.232.22.2.4.1.1.1.25
The power state of the blade. This will be other(1) if the rack does not report the information or if it could not be determined.
Status: optional Access: read-write
OBJECT-TYPE    
  INTEGER other(1), on(2), off(3), powerStagedOff(4), reboot(5)  

cpqRackServerBladeUIDState 1.3.6.1.4.1.232.22.2.4.1.1.1.26
The Unit Identifier LED. This value will be one of the following: other(1) The state of the LED could not be determined. Setting the LED state is not allowed. none(2) The LED is not present. Setting LED state is not allowed. ledOn(3) The LED is present and ON. The LED can be turned off by setting the cpqRackServerBladeUIDState to ledOff(4). ledOff(4) The LED is present and OFF. The LED can be turned on by setting the cpqRackServerBladeUIDState to ledOn(3).
Status: optional Access: read-write
OBJECT-TYPE    
  INTEGER other(1), none(2), ledOn(3), ledOff(4)  

cpqRackServerBladeSystemBIOSRevision 1.3.6.1.4.1.232.22.2.4.1.1.1.27
The server blade system bios revision. The string will be empty if the blade does not report the system bios revision or if it could not be determined.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..64)  

cpqRackServerBladeSystemBIOSFlashingStatus 1.3.6.1.4.1.232.22.2.4.1.1.1.28
Blade server system BIOS flashing / flash mode status indication. This will be other(1) if the rack does not report the information or if it could not be determined.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER other(1), normal(2), flashing(3)  

cpqRackServerBladeHasManagementDevice 1.3.6.1.4.1.232.22.2.4.1.1.1.29
The blade server contains one or more management devices. This will be true(2) if the blade server contains managers and false (1) if not or if it can't be detected.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER false(1), true(2)  

cpqRackServerBladeManagementDeviceFirmwareRevision 1.3.6.1.4.1.232.22.2.4.1.1.1.30
The server blade management device firwmware revision. The string will be empty if the blade does not report the management device firwmware revision or if it could not be determined.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..64)  

cpqRackServerBladeManagementDeviceFirmwareFlashingStatus 1.3.6.1.4.1.232.22.2.4.1.1.1.31
Blade server management device firwmware flashing / flash mode status indication. This will be other(1) if the rack does not report this information or if it could not be determined.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER other(1), normal(2), flashing(3)  

cpqRackServerBladeDiagnosticAdaptorPresence 1.3.6.1.4.1.232.22.2.4.1.1.1.32
This specifies if a blade diagnostic adaptor is currently plugged into the system.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER other(1), absent(2), present(3)  

cpqRackServerBladeASREnabled 1.3.6.1.4.1.232.22.2.4.1.1.1.33
Indicates whether the target blade server has Automatic Service Recovery feature enabled. This will be true(2) if the blade server has this feature eanbled and false (1) if not or if it can't be detected.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER false(1), true(2)  

cpqRackServerBladeFrontIOBlankingModeStatus 1.3.6.1.4.1.232.22.2.4.1.1.1.34
Indicates whether the target blade server has the front IO ports blanking feature enabled. This will be Active(3) if the blade server has this feature eanbled, Inactive (2) if not, or Unknown(1) if it can't be determined.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), inactive(2), active(3)  

cpqRackServerBladePOSTStatus 1.3.6.1.4.1.232.22.2.4.1.1.1.35
Blade server power-on self test (POST) status. This value will be one of the following: other(1) The state of the blade POST could not be determined. started(2) Blade has started Power-on-self-test (POST) process. completed(3) Blade has finished Power-on-self-test (POST) process. failed(4) Blade has failed to complete Power-on-self-test (POST) process and halted. This will be other(1) if the rack does not report this information or if it could not be determined.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER other(1), started(2), completed(3), failed(4)  

cpqRackServerBladePXEBootModeStatus 1.3.6.1.4.1.232.22.2.4.1.1.1.36
Indicates whether the target blade server is in PXE boot mode. This will be Active(3) if the blade server has this feature enbled, Inactive (2) if not, or Unknown(1) if it can't be determined.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), inactive(2), active(3)  

cpqRackServerBladePendingBootOrderChange 1.3.6.1.4.1.232.22.2.4.1.1.1.37
Blade server pending boot order setting change state. This value will be one of the following: other(1) - Unknown or cannot be determined none(2) - No Changes firstPXE(3) - Boot To Pre-Boot eXecution (PXE) First firstHDD(4) - First Boot To Local HD firstRBSU(5) - First Boot To ROM Based Setup Utility oncePXE(6) - Boot To Pre-Boot eXecution (PXE) Once onceHDD(7) - Boot To Local HD Once onceRBSU(8) - Boot To ROM Based Setup Utility Once alwaysPXE(9) - Always Boot To Pre-Boot eXecution (PXE) alwaysHDD(10) - Always Boot To Local HD alwaysRBSU(11) - Always Boot To ROM Based Setup Utility This will be other(1) if the rack does not report this information or if it could not be determined.
Status: optional Access: read-write
OBJECT-TYPE    
  INTEGER other(1), none(2), firstPXE(3), firstHDD(4), firstRBSU(5), oncePXE(6), onceHDD(7), onceRBSU(8), alwaysPXE(9), alwaysHDD(10), alwaysRBSU(11)  

cpqRackServerBladeWattageMax 1.3.6.1.4.1.232.22.2.4.1.1.1.38
Maximum wattage the server has consumed during this power cycle.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER  

cpqRackServerBladeWattageAvg 1.3.6.1.4.1.232.22.2.4.1.1.1.39
Average wattage the server is consuming, averaged over a period defined by the product.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER  

cpqRackServerBladeWattageMin 1.3.6.1.4.1.232.22.2.4.1.1.1.40
Minimum wattage the server has consumed, computed from a period defined by the product. Value will be 0 if not supported, but other wattage values are supported.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER  

cpqRackServerNetworkingTable 1.3.6.1.4.1.232.22.2.4.2.1
A table of rack server networking information.
Status: optional Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    CpqRackServerNetworkingEntry

cpqRackServerNetworkingEntry 1.3.6.1.4.1.232.22.2.4.2.1.1
A rack server networking description.
Status: optional Access: not-accessible
OBJECT-TYPE    
  CpqRackServerNetworkingEntry  

cpqRackServerNetworkingRack 1.3.6.1.4.1.232.22.2.4.2.1.1.1
A number that uniquely specifies this rack.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER  

cpqRackServerNetworkingChassis 1.3.6.1.4.1.232.22.2.4.2.1.1.2
A number that uniquely specifies this enclosure in the rack.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cpqRackServerNetworkingIndex 1.3.6.1.4.1.232.22.2.4.2.1.1.3
A number that uniquely specifies this server within the enclosure.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER  

cpqRackServerNetworkingName 1.3.6.1.4.1.232.22.2.4.2.1.1.4
The name of the server. The string will be empty if it could not be determined.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..64)  

cpqRackServerNetworkingEnclosureName 1.3.6.1.4.1.232.22.2.4.2.1.1.5
The name of the enclosure which contains the server. The string will be empty if the enclosure does not report the name or if it could not be determined.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..64)  

cpqRackServerNetworkingEthernetInterfaces 1.3.6.1.4.1.232.22.2.4.2.1.1.6
A number that specifies the amount of Ethernet network interfaces in the server.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER  

cpqRackServerNetworkingEthernetMACAddress 1.3.6.1.4.1.232.22.2.4.2.1.1.7
The MAC address for the Ethernet NIC populated in the server. The string will be empty if it could not be determined.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..64)  

cpqRackServerTempSensorTable 1.3.6.1.4.1.232.22.2.4.3.1
A table of rack server temperature sensor information.
Status: optional Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    CpqRackServerTempSensorEntry

cpqRackServerTempSensorEntry 1.3.6.1.4.1.232.22.2.4.3.1.1
A rack server temperature sensor description.
Status: optional Access: not-accessible
OBJECT-TYPE    
  CpqRackServerTempSensorEntry  

cpqRackServerTempSensorRack 1.3.6.1.4.1.232.22.2.4.3.1.1.1
A number that uniquely specifies this rack.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER  

cpqRackServerTempSensorChassis 1.3.6.1.4.1.232.22.2.4.3.1.1.2
A number that uniquely specifies this enclosure in the rack.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER  

cpqRackServerTempSensorIndex 1.3.6.1.4.1.232.22.2.4.3.1.1.3
A number that uniquely specifies this server within the enclosure.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER  

cpqRackServerTempSensorName 1.3.6.1.4.1.232.22.2.4.3.1.1.4
The name of the server. The string will be empty if it could not be determined.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..64)  

cpqRackServerTempSensorEnclosureName 1.3.6.1.4.1.232.22.2.4.3.1.1.5
The name of the enclosure which contains the server. The string will be empty if the enclosure does not report the name or if it could not be determined.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..64)  

cpqRackServerTempSensorCount 1.3.6.1.4.1.232.22.2.4.3.1.1.6
A number that specifies the amount of temperature sensors in the server.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER  

cpqRackServerTempSensorLocation 1.3.6.1.4.1.232.22.2.4.3.1.1.7
The location description of the temperature sensor within the blade server. The string will be empty if it could not be determined.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..64)  

cpqRackServerTempSensorCurrent 1.3.6.1.4.1.232.22.2.4.3.1.1.8
This is the current temperature sensor reading in degrees celsius. If this value cannot be determined by software, then a value of -1 will be returned.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER  

cpqRackServerTempSensorThreshold 1.3.6.1.4.1.232.22.2.4.3.1.1.9
This is the threshold temperature sensor setting in degrees celsius. This is the temperature in which the sensor will be considered to be in a tripped state this causing some action to occur depending on the type of the sensor. The action of temperature sensor threshold will be indicated by the cpqRackServerTempSensorType item. If the type is blowout(5), then the temperature sensor will cause the fans to speed up. If the type is caution(9), then the temperature sensor is in a degraded state. If the type is critical(15), then the enclosure will be considered as in a failed state. If this value cannot be determined by software, then a value of -1 will be returned.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER  

cpqRackServerTempSensorCondition 1.3.6.1.4.1.232.22.2.4.3.1.1.10
The Temperature sensor condition. This value will be one of the following: other(1) Temperature could not be determined. ok(2) The temperature sensor is within the normal operating range. degraded(3) The temperature sensor is outside of the normal operating range. failed(4) The temperature sensor detects a condition that could possibly overheat the system. The system will automatically shutdown if the failed(4) condition results, so it is unlikely that this value will ever be returned by the agent.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER other(1), ok(2), degraded(3), failed(4)  

cpqRackServerTempSensorType 1.3.6.1.4.1.232.22.2.4.3.1.1.11
This specifies the type of this instance of temperature sensor. This value will be one of the following: other(1) Temperature threshold type could not be determined. blowout(5) If a blowout(5) temperature sensor reaches its threshold, the fan or fans in the area of the temperature sensor will increase in speed in an attempt to reduce the temperature before a caution or critical threshold is reached. caution(9) If a caution(9) temperature sensor reaches its threshold, the cpqRackServerTempSensorCondition will be set to degraded(3) and the system will either continue or shutdown depending on the local blade server policy settings. critical(15) If a critical(15) temperature sensor reaches its threshold, cpqRackServerTempSensorCondition will be set to failed(4) and the blade server will shutdown.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER other(1), blowout(5), caution(9), critical(15)  

cpqRackPowerSupplyTable 1.3.6.1.4.1.232.22.2.5.1.1
A table of rack power supply information.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    CpqRackPowerSupplyEntry

cpqRackPowerSupplyEntry 1.3.6.1.4.1.232.22.2.5.1.1.1
A rack power supply description.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  CpqRackPowerSupplyEntry  

cpqRackPowerSupplyRack 1.3.6.1.4.1.232.22.2.5.1.1.1.1
A number that uniquely specifies this rack.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cpqRackPowerSupplyChassis 1.3.6.1.4.1.232.22.2.5.1.1.1.2
A number that uniquely specifies this power enclosure in the rack.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cpqRackPowerSupplyIndex 1.3.6.1.4.1.232.22.2.5.1.1.1.3
A number that uniquely specifies this power supply in the enclosure.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cpqRackPowerSupplyEnclosureName 1.3.6.1.4.1.232.22.2.5.1.1.1.4
The name of the power supply enclosure in which this power supply resides. The string will be empty if the enclosure does not report the name or it could not be determined.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..64)  

cpqRackPowerSupplySerialNum 1.3.6.1.4.1.232.22.2.5.1.1.1.5
The serial number of the power supply. The string will be empty if the power supply does not report the serial number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..64)  

cpqRackPowerSupplyPartNumber 1.3.6.1.4.1.232.22.2.5.1.1.1.6
The part number of the power supply. The string will be empty if the power supply does not report this function.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..64)  

cpqRackPowerSupplySparePartNumber 1.3.6.1.4.1.232.22.2.5.1.1.1.7
The spare part number of the power supply. The string will be empty if the power supply does not report this function.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..64)  

cpqRackPowerSupplyFWRev 1.3.6.1.4.1.232.22.2.5.1.1.1.8
The firmware revision of the power supply. The string will be empty if the power supply does not report the firmware revision.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..64)  

cpqRackPowerSupplyMaxPwrOutput 1.3.6.1.4.1.232.22.2.5.1.1.1.9
The maximum power output of the power supply in watts. The value will be -1 if the power supply does not report the value.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cpqRackPowerSupplyCurPwrOutput 1.3.6.1.4.1.232.22.2.5.1.1.1.10
The current power output of the power supply in watts. The value will be -1 if the power supply does not report the value.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cpqRackPowerSupplyPosition 1.3.6.1.4.1.232.22.2.5.1.1.1.11
The position of the power supply within the power enclosure. This will be -1 if the power enclosure does not report the power supply information or it could not be determined.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cpqRackPowerSupplyIntakeTemp 1.3.6.1.4.1.232.22.2.5.1.1.1.12
The current air temperature at the intake of the power supply in degrees celsius. The value will be -1 if the power supply does not report the value.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cpqRackPowerSupplyExhaustTemp 1.3.6.1.4.1.232.22.2.5.1.1.1.13
The current air temperature at the exhaust of the power supply in degrees celsius. The value will be -1 if the power supply does not report the value.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cpqRackPowerSupplyStatus 1.3.6.1.4.1.232.22.2.5.1.1.1.14
The status of the power supply.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noError(1), generalFailure(2), bistFailure(3), fanFailure(4), tempFailure(5), interlockOpen(6), epromFailed(7), vrefFailed(8), dacFailed(9), ramTestFailed(10), voltageChannelFailed(11), orringdiodeFailed(12), brownOut(13), giveupOnStartup(14), nvramInvalid(15), calibrationTableInvalid(16)  

cpqRackPowerSupplyInputLineStatus 1.3.6.1.4.1.232.22.2.5.1.1.1.15
The status of line input power.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noError(1), lineOverVoltage(2), lineUnderVoltage(3), lineHit(4), brownOut(5), linePowerLoss(6)  

cpqRackPowerSupplyPresent 1.3.6.1.4.1.232.22.2.5.1.1.1.16
This specifies if the power supply described is present in the enclosure.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(1), absent(2), present(3)  

cpqRackPowerSupplyCondition 1.3.6.1.4.1.232.22.2.5.1.1.1.17
The condition of the power supply. This value will be one of the following: other(1) The status could not be determined or not present. ok(2) The power supply is operating normally. degraded(3) A temperature sensor, fan or other power supply component is outside of normal operating range. failed(4) A power supply component detects a condition that could possibly damage the system.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(1), ok(2), degraded(3), failed(4)  

cpqRackPowerSupplyEnclosureSerialNum 1.3.6.1.4.1.232.22.2.5.1.1.1.18
The serial number of the power supply enclosure in which this power supply resides. The string will be empty if the enclosure does not report the serial number or it could not be determined.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..64)  

cpqRackNetConnectorTable 1.3.6.1.4.1.232.22.2.6.1.1
A table of rack network connector information.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    CpqRackNetConnectorEntry

cpqRackNetConnectorEntry 1.3.6.1.4.1.232.22.2.6.1.1.1
A rack network connector description.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  CpqRackNetConnectorEntry  

cpqRackNetConnectorRack 1.3.6.1.4.1.232.22.2.6.1.1.1.1
A number that uniquely specifies this rack.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cpqRackNetConnectorChassis 1.3.6.1.4.1.232.22.2.6.1.1.1.2
A number that uniquely specifies this server enclosure in the rack.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cpqRackNetConnectorIndex 1.3.6.1.4.1.232.22.2.6.1.1.1.3
A number that uniquely specifies this network connector in the rack.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cpqRackNetConnectorEnclosureName 1.3.6.1.4.1.232.22.2.6.1.1.1.4
The name of the network connector enclosure. The string will be empty if the enclosure does not report the name or it could not be determined.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..64)  

cpqRackNetConnectorName 1.3.6.1.4.1.232.22.2.6.1.1.1.5
The name of the network connector. The string will be empty if the network connector does not report the name or it could not be determined.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..64)  

cpqRackNetConnectorModel 1.3.6.1.4.1.232.22.2.6.1.1.1.6
The model name of the network connector. The string will be empty if the network connector does not report the model information.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..64)  

cpqRackNetConnectorSerialNum 1.3.6.1.4.1.232.22.2.6.1.1.1.7
The serial number of the network connector. The string will be empty if the network connector does not report the serial number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..64)  

cpqRackNetConnectorPartNumber 1.3.6.1.4.1.232.22.2.6.1.1.1.8
The part number of the network connector. The string will be empty if the enclosure does not report this function.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..64)  

cpqRackNetConnectorSparePartNumber 1.3.6.1.4.1.232.22.2.6.1.1.1.9
The spare part number of the network connector. The string will be empty if the enclosure does not report this function.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..64)  

cpqRackNetConnectorFWRev 1.3.6.1.4.1.232.22.2.6.1.1.1.10
The firmware revision of the network connector. The string will be empty if the network connector does not report the firmware revision.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..64)  

cpqRackNetConnectorType 1.3.6.1.4.1.232.22.2.6.1.1.1.11
The type of network connector within the enclosure.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(1), passive(2), active(3)  

cpqRackNetConnectorLocation 1.3.6.1.4.1.232.22.2.6.1.1.1.12
The location of the network connector within the enclosure.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..64)  

cpqRackNetConnectorPresent 1.3.6.1.4.1.232.22.2.6.1.1.1.13
This specifies if the network connector described is present in the enclosure.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(1), absent(2), present(3)  

cpqRackNetConnectorHasFuses 1.3.6.1.4.1.232.22.2.6.1.1.1.14
The network connector contains fuses. This will be true(2) is the network connector contains fuses. The cpqRackCommonEnclosureFuseTable will contain the fuse specific information. Match the cpqRackNetworkEnclosureSerialNum in this table to the serial number in the cpqRackCommonEnclosureFusTable to get complete information on the fuses.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER false(1), true(2)  

cpqRackNetConnectorEnclosureSerialNum 1.3.6.1.4.1.232.22.2.6.1.1.1.15
The serial number of the enclosure containing the network connector. The string will be empty if the enclosure does not report the serial number or it could not be determined.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..64)  

cpqRackNetConnectorTechnologyType 1.3.6.1.4.1.232.22.2.6.1.1.1.16
The type of network connector within the enclosure.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(1), passive(2), active(3)  

cpqRackNetConnectorDeviceType 1.3.6.1.4.1.232.22.2.6.1.1.1.17
The type of interrconnect in the enclosure. This will be -1 if it is not reported or can not be deteremined.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noconnect(1), network(2), fibrechannel(3), sas(4), inifiband(5), pciexpress(6)  

cpqRackSystemObjectIdentification 1.3.6.1.4.1.232.22.3.1
The hardware identification string. The string will reported by the rack firmware.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..64)  

cpqRackNameChanged 22001
Rack name has changed. This trap signifies that an agent or utility has changed the name of the rack. Each of the server blades in each of the enclosure within the rack will be updated to reflect the new rack name. It may take several minutes for the rack name change to be propagated throughout the entire rack. User Action: None.
TRAP-TYPE    

cpqRackEnclosureNameChanged 22002
The enclosure name has changed. This trap signifies that an agent or utility has changed the name of an enclosure within the rack. Each of the components within the rack will be updated to reflect the new enclosure name. It may take several minutes for the enclosure name change to be propagated throughout the entire enclosure. User Action: None.
TRAP-TYPE    

cpqRackEnclosureRemoved 22003
The enclosure has been removed. This trap signifies that an enclosure has been removed from the rack. User Action: None.
TRAP-TYPE    

cpqRackEnclosureInserted 22004
The enclosure has been inserted. This trap signifies that an enclosure has been inserted into the rack. User Action: None.
TRAP-TYPE    

cpqRackEnclosureTempFailed 22005
The enclosure temperature status has been set to failed. This trap signifies that a enclosure temperature sensor has been tripped indicating an overheat condition. User Action: Shutdown the enclosure and possibly the rack as soon as possible. Insure all fans are working properly and that air flow in the rack has not been blocked.
TRAP-TYPE    

cpqRackEnclosureTempDegraded 22006
The enclosure temperature status has been set to degraded. This trap signifies that an enclosure temperature sensor has been tripped indicating a possible overheat condition. User Action: Shutdown the enclosure and possibly the rack as soon as possible. Insure all fans are working properly and that air flow in the rack has not been blocked.
TRAP-TYPE    

cpqRackEnclosureTempOk 22007
The enclosure temperature status has been set to ok. This trap signifies that an enclosure temperature sensor has returned to normal. User Action: None.
TRAP-TYPE    

cpqRackEnclosureFanFailed 22008
The enclosure fan status has been set to failed. This trap signifies that an enclosure fan has failed and no other fans in the redundant fan group are operating. This may result in overheating of the enclosure. User Action: Replace the fan as soon as possible.
TRAP-TYPE    

cpqRackEnclosureFanDegraded 22009
The enclosure fan status has been set to degraded. This trap signifies that an enclosure fan has failed but other fans in the redundant fan group are still operating. This may result in overheating of the enclosure. User Action: Replace the fan as soon as possible.
TRAP-TYPE    

cpqRackEnclosureFanOk 22010
The enclosure fan status has been set to ok. This trap signifies that an enclosure fan has returned to normal operation. User Action: None.
TRAP-TYPE    

cpqRackEnclosureFanRemoved 22011
The enclosure fan has been removed. User Action: None.
TRAP-TYPE    

cpqRackEnclosureFanInserted 22012
The enclosure fan has been inserted. User Action: None.
TRAP-TYPE    

cpqRackPowerSupplyFailed 22013
The power supply status has been set to failed. This trap signifies that a power supply has failed. User Action: Replace the power supply as soon as possible.
TRAP-TYPE    

cpqRackPowerSupplyDegraded 22014
The power supply status has been set to degraded. This trap signifies that a power supply has degraded. User Action: Replace the power supply as soon as possible.
TRAP-TYPE    

cpqRackPowerSupplyOk 22015
The power supply status has been set to ok. This trap signifies that a power supply has returned to normal operation. User Action: None.
TRAP-TYPE    

cpqRackPowerSupplyRemoved 22016
The power supply has been removed. User Action: None.
TRAP-TYPE    

cpqRackPowerSupplyInserted 22017
The power supply has been inserted. User Action: None.
TRAP-TYPE    

cpqRackPowerSubsystemNotRedundant 22018
The rack power subsystem is no longer in a redundant state. User Action: Replace any failed power supplies as soon as possible to return the system to a redundant state.
TRAP-TYPE    

cpqRackPowerSubsystemLineVoltageProblem 22019
The rack power supply detected an input line voltage problem. User Action: Check the power input for the power supply or replace any failed power supplies as soon as possible.
TRAP-TYPE    

cpqRackPowerSubsystemOverloadCondition 22020
The rack power subsystem overload condition. User Action: Replace any failed power supplies as soon as possible to return the system to a redundant state.
TRAP-TYPE    

cpqRackPowerShedAutoShutdown 22021
Server shutdown due to power shedding. The server blade was shutdown due to a lack of power. User Action: Check power connections or add power supplies.
TRAP-TYPE    

cpqRackServerPowerOnFailedNotRedundant 22022
Server power on prevented to preserve redundancy. There is not enough power to power on the server blade and maintain redundancy for the other blades in the enclosure. User Action: Check power connections or add power supplies.
TRAP-TYPE    

cpqRackServerPowerOnFailedNotEnoughPower 22023
Inadequate power to power on. There is not enough power to power on the server blade. User Action: Check power connections or add power supplies.
TRAP-TYPE    

cpqRackServerPowerOnFailedEnclosureNotFound 22024
Inadequate power to power on. There is not enough power to power on the server blade. The server enclosure micro-controller was not found. User Action: Check server enclosure connections or add power supplies.
TRAP-TYPE    

cpqRackServerPowerOnFailedPowerChassisNotFound 22025
Inadequate power to power on. There is not enough power to power on the server blade. The power enclosure micro-controller was not found. User Action: Check power enclosure connections or add power supplies.
TRAP-TYPE    

cpqRackServerPowerOnManualOverride 22026
Server power on via manual override. The server blade was powered on by a manual override. User Action: None.
TRAP-TYPE    

cpqRackFuseOpen 22027
Fuse open. The fuse has been tripped. User Action: Check enclosure and / or blade power connections and reset the fuse.
TRAP-TYPE    

cpqRackServerBladeRemoved 22028
Server blade removed. The server blade has been removed from the enclosure. User Action: None.
TRAP-TYPE    

cpqRackServerBladeInserted 22029
Server blade inserted. The server blade has been inserted into the enclosure. User Action: None.
TRAP-TYPE    

cpqRackPowerChassisNotLoadBalanced 22030
Power subsystem not load balanced. The power subsystem is out of balance for this power enclosure. User Action: Check the power enclosure and power supplies. Replace any failed or degraded power supplies. Add additional power supplies if needed.
TRAP-TYPE    

cpqRackPowerChassisDcPowerProblem 22031
Power subsystem DC power problem. There is a power subsystem DC power problem for this power enclosure. User Action: Check the power enclosure and power supplies. Replace any failed or degraded power supplies.
TRAP-TYPE    

cpqRackPowerChassisAcFacilityPowerExceeded 22032
Power subsystem AC facility input power exceeded. There is a power subsystem Power subsystem AC facility input power exceeded for this power enclosure. User Action: Check the power enclosure and power supplies. Replace any failed or degraded power supplies.
TRAP-TYPE    

cpqRackPowerUnknownPowerConsumption 22033
Unknown power consumption. There is an unknown power consumer drawing power. User Action: Check the power enclosure and power supplies. Replace any failed or degraded power supplies.
TRAP-TYPE    

cpqRackPowerChassisLoadBalancingWireMissing 22034
Power subsystem load balancing wire missing. The power subsystem load balancing wire missing. User Action: Connect the load balancing wire.
TRAP-TYPE    

cpqRackPowerChassisTooManyPowerChassis 22035
Power subsystem has too may power enclosures. The maximum number of power enclosures has been exceeded. User Action: Remove the extra power enclosure.
TRAP-TYPE    

cpqRackPowerChassisConfigError 22036
Power subsystem improperly configured. The power subsystem has been improperly configured. User Action: Check the cabling of the power enclosure.
TRAP-TYPE    

cpqRackEnclosureManagerDegraded 22037
The Onboard Administrator or other management processor status has been set to degraded. This trap signifies that either an Onboard Administrator has failed but the other Onboard Administrator is still operating, or one or more management processors is in a non-optimal operating state. User Action: For C-Class enclosures, replace the Onboard Administrator as soon as possible. For all others please refer to product documenation for possible corrective actions
TRAP-TYPE    

cpqRackEnclosureManagerOk 22038
The Onboard Administrator or other management processor's status has been set to ok. This trap signifies that an Onboard Administrator or other management processor has returned to normal operation. User Action: None.
TRAP-TYPE    

cpqRackEnclosureManagerRemoved 22039
The Onboard Administrator has been removed. User Action: None.
TRAP-TYPE    

cpqRackEnclosureManagerInserted 22040
The Onboard Administrator or other management processor has been inserted. User Action: None.
TRAP-TYPE    

cpqRackManagerPrimaryRole 22041
The Onboard Administrator or other management processor has taken the role of primary. User Action: None.
TRAP-TYPE    

cpqRackServerBladeEKeyingFailed 22042
The server blade e-keying has failed. This trap signifies that a server blade e-keying has failed and there is a port mapping problem between a server mezz card and the interconnect. User Action: Reconfigure server blade mezz cards.
TRAP-TYPE    

cpqRackServerBladeEKeyingOK 22043
The server blade e-keying is ok. This trap signifies that a server blade e-keying has returned to normal operation. User Action: None.
TRAP-TYPE    

cpqRackNetConnectorRemoved 22044
Interconnect removed. The interconnect has been removed from the enclosure. User Action: None.
TRAP-TYPE    

cpqRackNetConnectorInserted 22045
Interconnect inserted. The interconnect has been inserted into the enclosure. User Action: None.
TRAP-TYPE    

cpqRackNetConnectorFailed 22046
The interconnect status has been set to failed. This trap signifies that a interconnect has failed. User Action: Replace the interconnect as soon as possible.
TRAP-TYPE    

cpqRackNetConnectorDegraded 22047
The interconnect status has been set to degraded. This trap signifies that a interconnect has degraded. User Action: Replace the interconnect as soon as possible.
TRAP-TYPE    

cpqRackNetConnectorOk 22048
The interconnect status has been set to ok. This trap signifies that a interconnect has returned to normal operation. User Action: None.
TRAP-TYPE    

cpqRackServerBladeToLowPower 22049
The server blade requested to low power. User Action: None.
TRAP-TYPE    

cpqRackServerBladeRemoved2 22050
Server blade removed. The server blade has been removed from the enclosure. User Action: None.
TRAP-TYPE    

cpqRackServerBladeInserted2 22051
Server blade inserted. The server blade has been inserted into the enclosure. User Action: None.
TRAP-TYPE    

cpqRackServerBladeStatusRepaired 22052
Server blade repaired. The server blade status has changed to OK. User Action: None.
TRAP-TYPE    

cpqRackServerBladeStatusDegraded 22053
Server blade health status Degraded. The server blade health status has changed to Degraded. User Action: Check blade server and enclosure SYSLOG.
TRAP-TYPE    

cpqRackServerBladeStatusCritical 22054
Server blade health status Critical. The server blade health status has changed to Critical. User Action: Check blade server and enclosure SYSLOG.
TRAP-TYPE    

cpqRackServerBladeGrpCapTimeout 22055
The server blade is not responding to the group capper. The server blade is not responding to capping requests from the enclosure group capper User Action: Reset the iLO management processor.
TRAP-TYPE    

cpqRackServerBladeUnexpectedShutdown 22056
Server blade shutdown unexpectadly. An unexpected shutdown event has occurred for this server blade. User Action: Check blade server and enclosure SYSLOG.
TRAP-TYPE    

cpqRackServerBladeMangementControllerFirmwareUpdating 22057
Server blade's management controller firmware updating. This server blade's management controller has started updating it's firmware. User Action: None.
TRAP-TYPE    

cpqRackServerBladeMangementControllerFirmwareUpdateComplete 22058
Server blade's management controller firmware update has completed. This server blade's management controller has finished updating it's firmware. User Action: None.
TRAP-TYPE    

cpqRackServerBladeSystemBIOSFirmwareUpdating 22059
Server blade's system BIOS firmware updating. This server blade's system BIOS has started updating. User Action: None.
TRAP-TYPE    

cpqRackServerBladeSystemBIOSFirmwareUpdateCompleted 22060
Server blade's system BIOS firmware update complete. This server blade's system BIOS has completed updating. User Action: None.
TRAP-TYPE    

cpqRackServerBladeFrontIOBlankingActive 22061
Server blade has disabled front IO ports. Front IO blanking status has changed to active for this server blade. User Action: None.
TRAP-TYPE    

cpqRackServerBladeRemoteFrontIOBlankingInactive 22062
Server blade has front IO blanking mode now inactive. Front IO blanking status has changed to inactive for this server blade. User Action: None.
TRAP-TYPE    

cpqRackServerBladeDiagnosticAdaptorInserted 22063
Server blade diagnostic adaptor inserted. Blade diagnostic adaptor status has changed to inserted for this server blade. User Action: None.
TRAP-TYPE    

cpqRackServerBladeDiagnosticAdaptorRemoved 22064
Server blade diagnostic adaptor removed. Blade diagnostic adaptor status has changed to removed for this server blade. User Action: None.
TRAP-TYPE    

cpqRackServerBladeEnteredPXEBootMode 22065
Server blade has entered PXE Boot Mode. Server blade Pre-Boot-eXecution (PXE) Mode started. User Action: None.
TRAP-TYPE    

cpqRackServerBladeExitedPXEBootMode 22066
Server blade has exited PXE Boot Mode. Server blade Pre-Boot-eXecution (PXE) Mode exited. User Action: None.
TRAP-TYPE    

cpqRackServerBladeWarmReset 22067
Server blade has been warm reset. Server blade has experienced a warm reset. User Action: None.
TRAP-TYPE    

cpqRackServerBladePOSTCompleted 22068
Server blade system BIOS POST complete. Server blade has completed system BIOS Power-On-Self-Test (POST). User Action: None.
TRAP-TYPE    

cpqRackServerBladePoweredOn 22069
Server blade has powered on. User Action: None.
TRAP-TYPE    

cpqRackServerBladePoweredOff 22070
Server blade has powered off. User Action: None.
TRAP-TYPE    

cpqRackInformationalEAETrap 22071
EAE Informational trap
TRAP-TYPE    

cpqRackMinorEAETrap 22072
EAE Minor trap
TRAP-TYPE    

cpqRackMajorEAETrap 22073
EAE Major trap
TRAP-TYPE    

cpqRackCriticalEAETrap 22074
EAE Critical trap
TRAP-TYPE    

cpqRackPowerMinorEAETrap 22075
FlexFabric Cmdr Power Subsystem Minor trap. User Action: For FlexFabric Cmdr, please refer to product documentation for possible corrective actions.
TRAP-TYPE    

cpqRackPowerMajorEAETrap 22076
FlexFabric Cmdr Power Subsystem Major trap. User Action: For FlexFabric Cmdr, please refer to product documentation for possible corrective actions.
TRAP-TYPE    

cpqRackPowerCriticalEAETrap 22077
FlexFabric Cmdr Power Subsystem Critical trap. User Action: For FlexFabric Cmdr, please refer to product documentation for possible corrective actions.
TRAP-TYPE