COM21-HCXTX-MIB

File: COM21-HCXTX-MIB.mib (20057 bytes)

Imported modules

SNMPv2-SMI SNMPv2-TC COM21-HCX-MIB
COM21-HCXALM-MIB

Imported symbols

MODULE-IDENTITY OBJECT-TYPE NOTIFICATION-TYPE
Integer32 IpAddress Gauge32
TimeTicks DisplayString MacAddress
com21 com21Hcx com21Traps
hcxAlmSeverity hcxEventLogTime

Defined Types

Gain  
INTEGER 0..255    

PrimServiceState  
INTEGER is(1), oos(2)    

Defined Values

com21HcxTx 1.3.6.1.4.1.1141.2.20
This is the Com21 ComController TX Unit Control MIB module. COM21 Part# 005-0025-00
MODULE-IDENTITY    

com21HcxDnstrmPortGroup 1.3.6.1.4.1.1141.2.21
OBJECT IDENTIFIER    

com21HcxDnstrmStatsGroup 1.3.6.1.4.1.1141.2.22
OBJECT IDENTIFIER    

com21HcxDnstrmUnitGroup 1.3.6.1.4.1.1141.2.23
OBJECT IDENTIFIER    

hcxDownstreamShelfId 1.3.6.1.4.1.1141.2.23.1
contains the associated shelf id.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 1..2  

hcxDownstreamSlotId 1.3.6.1.4.1.1141.2.23.2
contains downstream slot id.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hcxDownstreamHardwareVersion 1.3.6.1.4.1.1141.2.23.3
contains the hardware version of the TX card. An empty string if card not present.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(16)  

hcxDownstreamBootVersion 1.3.6.1.4.1.1141.2.23.4
contains the version of the TX card boot ROM. An empty string if card not present.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(16)  

hcxDnstreamUnitPrimServState 1.3.6.1.4.1.1141.2.23.5
contains primary service state of the Downstream Unit.
Status: current Access: read-only
OBJECT-TYPE    
  PrimServiceState  

hcxDnstrmUnitPrimStateChange 1.3.6.1.4.1.1141.4.60
Generated whenever a the hcxDnstreamUnitPrimServState changes in value. This an event with no clear condition. Only severity is WARNING.
Status: current Access: read-only
NOTIFICATION-TYPE    

hcxDnstreamUnitSecServState 1.3.6.1.4.1.1141.2.23.6
contains a string defining the secondary service states of the Downstream Unit. The substrings supported by the Downstream Unit shall be: TEST - in test, as set by hcxDnUnitConfigState, STBY - standby, again set by hcxDnUnitConfigState, MT - maintenance, set by hcxDnUnitConfigState, FAULT - hardware failure, UNEQ - unequipped.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(16)  

hcxDnstrmUnitSecStateChange 1.3.6.1.4.1.1141.4.61
Generated whenever a the hcxDnstreamUnitSecServState changes in value. This an event with no clear condition. Only severity is WARNING.
Status: current Access: read-only
NOTIFICATION-TYPE    

hcxDnUnitConfigState 1.3.6.1.4.1.1141.2.23.7
The Downstream Unit State is an active-value. Note that because we have only one port per card then this state change is exactly the same as hcxDnstrmPortState. Note that initially standby will be the same state as offline. Later this will change when TX redundancy is supported. offline is default.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER offline(2000), online(2001), test(2002), standby(2003)  

hcxDnUnitRestartAction 1.3.6.1.4.1.1141.2.23.8
The TX Unit Action is an active-value. The setting of this attibute to restart(2) causes the TX card to reset and download a new image.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER nil(1), restart(2)  

hcxDnDiagTestAction 1.3.6.1.4.1.1141.2.23.9
This attribute is used to invoke the internal TX diagnostic test. In order to activate this test, the card must be placed in the test state.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER nil(1), execute(2)  

hcxDnDiagTestComplete 1.3.6.1.4.1.1141.4.62
This notification is generated whenever the TX internal diagnostic tests are completed. This an event with no clear condition. Only severity is WARNING.
Status: current Access: read-write
NOTIFICATION-TYPE    

hcxDnDiagTestResult 1.3.6.1.4.1.1141.2.23.10
This attribute contains the result of the last TX diagnostic test. Details TBD.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER inprogress(1), success(2), failure(3), invalidState(4)  

hcxDnTestStatusLed 1.3.6.1.4.1.1141.2.23.11
The TX Test Status LED is a read-only attribute which describes the condition of the TX Test Status light emitting diode located on the RX board. A value of on(1) indicates that a service effecting test is in progress and that the LED is illuminated. off if card not present.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER on(1), off(2)  

hcxDnTestStatusLedChange 1.3.6.1.4.1.1141.4.63
generated whenever there is a change in test LED status. This an event with no clear condition. Only severity is WARNING.
Status: current Access: read-only
NOTIFICATION-TYPE    

hcxDnFaultStatusLed 1.3.6.1.4.1.1141.2.23.12
The RX Fault Status LED is a read-only attribute which describes the condition of the TX Fault Status light emitting diode located on the TX board. A value of on(1) indicates that an fault condition has been detected (for which a trap will have been issued) and the LED is illuminated. off if card not present.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER on(1), off(2)  

hcxDnFaultStatusLedChange 1.3.6.1.4.1.1141.4.64
generated whenever there is a change in the Fault LED status. This an event with no clear condition. Only severity is WARNING.
Status: current Access: read-only
NOTIFICATION-TYPE    

hcxDnOperationFailure 1.3.6.1.4.1.1141.4.65
This notification is generated by the CC whenever a TX card fails to respond correctly to a request. This failure could indicate either a resource problem or software failure. Note that if a TX card failures to respond completely to a CC request, then a hcxInsertChange trap shall be generated. This is an event with no clear condition. Only severity is WARNING.
Status: current Access: read-only
NOTIFICATION-TYPE    

hcxDownstreamSerialNumber 1.3.6.1.4.1.1141.2.23.13
contains the serial number of the TX card. An empty string if card not present.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(16)  

hcxDownstreamPortId 1.3.6.1.4.1.1141.2.21.1
contains downstream port id. Initially at least, only 1 supported.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hcxXmitFrequency 1.3.6.1.4.1.1141.2.21.2
Contains the transmit frequency of the RF port in KHz. If this value is changed AFTER the acquisition of ComPorts then a corresponding change to the stuXmitFrequency attribute shall be broadcast to all the acquired ComPorts. Minimum step size is 200. i.e. 200000hz. Default is 0.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 88000..800000  

hcxXmitGain 1.3.6.1.4.1.1141.2.21.3
Transmit gain is used to specify the power level in the ComController transmitter. Default is 0.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 45..60  

hcxSynthLockLossDetected 1.3.6.1.4.1.1141.4.68
Default severity is MINOR.
Status: current Access: read-write
NOTIFICATION-TYPE    

hcxSynthLockLossClear 1.3.6.1.4.1.1141.4.69
Severity is CLEARED.
Status: current Access: read-write
NOTIFICATION-TYPE    

hcxLossOfFrameClkDetected 1.3.6.1.4.1.1141.4.70
Default severity is MINOR.
Status: current Access: read-write
NOTIFICATION-TYPE    

hcxLossOfFrameClkClear 1.3.6.1.4.1.1141.4.71
Severity is CLEARED.
Status: current Access: read-write
NOTIFICATION-TYPE    

hcxStatsCurrMinTxCells 1.3.6.1.4.1.1141.2.22.1
Represents the number of cells transmitted in the current 15 minute period.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

hcxStatsCurrMinTxNullCells 1.3.6.1.4.1.1141.2.22.2
Represents the number of null cells transmitted in the current 15 minute period.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

hcxStatsPrevMinTxCells 1.3.6.1.4.1.1141.2.22.3
Represents the number of cells transmitted in the previous 15 minute period.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

hcxStatsPrevMinTxNullCells 1.3.6.1.4.1.1141.2.22.4
Represents the number of null cells transmitted in the previous 15 minute period.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

hcxDownstreamUtil 1.3.6.1.4.1.1141.2.22.5
Represents the percentage of utilization on the downstream channel - the RF TX will stuff with null cells to match line rate. i.e. traffic cells/(traffic cells + null cells) * 100. This figure is updated every second.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

hcxStatsClearTxCurrStats 1.3.6.1.4.1.1141.2.22.6
This attribute is used to clear current TX statistics counters in this group. This operation is only possible if the hcxStatsControl attribute is set to wrapCurr.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER nil(1), clear(2)