CISCO-SNA-LLC-MIB

File: CISCO-SNA-LLC-MIB.mib (107200 bytes)

Imported modules

SNMPv2-SMI SNMPv2-TC SNMPv2-CONF
RFC1213-MIB CISCO-SMI

Imported symbols

MODULE-IDENTITY OBJECT-TYPE NOTIFICATION-TYPE
Counter32 Integer32 TimeTicks
Gauge32 DisplayString RowStatus
TimeStamp MacAddress MODULE-COMPLIANCE
OBJECT-GROUP ifIndex ciscoExperiment

Defined Types

LlcPortAdminEntry  
SEQUENCE    
  llcPortVirtualIndex Integer32
  llcPortAdminName DisplayString
  llcPortAdminMaxSaps Gauge32
  llcPortAdminMaxCcs Gauge32
  llcPortAdminMaxPDUOctets Integer32
  llcPortAdminMaxUnackedIPDUsSend INTEGER
  llcPortAdminMaxUnackedIPDUsRcv INTEGER
  llcPortAdminMaxRetransmits Integer32
  llcPortAdminAckTimer TimeTicks
  llcPortAdminPbitTimer TimeTicks
  llcPortAdminRejTimer TimeTicks
  llcPortAdminBusyTimer TimeTicks
  llcPortAdminInactTimer TimeTicks
  llcPortAdminDelayAckCount Integer32
  llcPortAdminDelayAckTimer TimeTicks
  llcPortAdminNw Integer32

LlcPortOperEntry  
SEQUENCE    
  llcPortOperMacAddress MacAddress
  llcPortOperNumSaps Gauge32
  llcPortOperHiWaterNumSaps Gauge32
  llcPortOperSimRim INTEGER
  llcPortOperLastModifyTime TimeStamp

LlcPortStatsEntry  
SEQUENCE    
  llcPortStatsPDUsIn Counter32
  llcPortStatsPDUsOut Counter32
  llcPortStatsOctetsIn Counter32
  llcPortStatsOctetsOut Counter32
  llcPortStatsTESTCommandsIn Counter32
  llcPortStatsTESTResponsesOut Counter32
  llcPortStatsLocalBusies Counter32
  llcPortStatsUnknownSaps Counter32

LlcSapAdminEntry  
SEQUENCE    
  llcSapNumber INTEGER
  llcSapAdminMaxPDUOctets Integer32
  llcSapAdminMaxUnackedIPDUsSend INTEGER
  llcSapAdminMaxUnackedIPDUsRcv INTEGER
  llcSapAdminMaxRetransmits Integer32
  llcSapAdminAckTimer TimeTicks
  llcSapAdminPbitTimer TimeTicks
  llcSapAdminRejTimer TimeTicks
  llcSapAdminBusyTimer TimeTicks
  llcSapAdminInactTimer TimeTicks
  llcSapAdminDelayAckCount Integer32
  llcSapAdminDelayAckTimer TimeTicks
  llcSapAdminNw Integer32

LlcSapOperEntry  
SEQUENCE    
  llcSapOperStatus INTEGER
  llcSapOperNumCcs Integer32
  llcSapOperHiWaterNumCcs Gauge32
  llcSapOperLlc2Support INTEGER

LlcSapStatsEntry  
SEQUENCE    
  llcSapStatsLocalBusies Counter32
  llcSapStatsRemoteBusies Counter32
  llcSapStatsIFramesIn Counter32
  llcSapStatsIFramesOut Counter32
  llcSapStatsIOctetsIn Counter32
  llcSapStatsIOctetsOut Counter32
  llcSapStatsSFramesIn Counter32
  llcSapStatsSFramesOut Counter32
  llcSapStatsRetransmitsOut Counter32
  llcSapStatsREJsIn Counter32
  llcSapStatsREJsOut Counter32
  llcSapStatsWwCount Counter32
  llcSapStatsTESTCommandsIn Counter32
  llcSapStatsTESTCommandsOut Counter32
  llcSapStatsTESTResponsesIn Counter32
  llcSapStatsTESTResponsesOut Counter32
  llcSapStatsXIDCommandsIn Counter32
  llcSapStatsXIDCommandsOut Counter32
  llcSapStatsXIDResponsesIn Counter32
  llcSapStatsXIDResponsesOut Counter32
  llcSapStatsUIFramesIn Counter32
  llcSapStatsUIFramesOut Counter32
  llcSapStatsUIOctetsIn Counter32
  llcSapStatsUIOctetsOut Counter32
  llcSapStatsConnectOk Counter32
  llcSapStatsConnectFail Counter32
  llcSapStatsDisconnect Counter32
  llcSapStatsDisconnectFRMRSend Counter32
  llcSapStatsDisconnectFRMRRcv Counter32
  llcSapStatsDisconnectTimer Counter32
  llcSapStatsDMsInABM Counter32
  llcSapStatsSABMEsInABM Counter32

LlcCcAdminEntry  
SEQUENCE    
  llcCcRMac MacAddress
  llcCcRSap INTEGER
  llcCcAdminBounce INTEGER
  llcCcAdminMaxPDUOctets Integer32
  llcCcAdminMaxUnackedIPDUsSend INTEGER
  llcCcAdminMaxUnackedIPDUsRcv INTEGER
  llcCcAdminMaxRetransmits Integer32
  llcCcAdminAckTimer TimeTicks
  llcCcAdminPbitTimer TimeTicks
  llcCcAdminRejTimer TimeTicks
  llcCcAdminBusyTimer TimeTicks
  llcCcAdminInactTimer TimeTicks
  llcCcAdminDelayAckCount Integer32
  llcCcAdminDelayAckTimer TimeTicks
  llcCcAdminNw Integer32
  llcCcAdminRowStatus RowStatus

LlcCcOperEntry  
SEQUENCE    
  llcCcOperState INTEGER
  llcCcOperMaxIPDUOctetsSend Integer32
  llcCcOperMaxIPDUOctetsRcv Integer32
  llcCcOperMaxUnackedIPDUsSend INTEGER
  llcCcOperMaxUnackedIPDUsRcv INTEGER
  llcCcOperMaxRetransmits Integer32
  llcCcOperAckTimer TimeTicks
  llcCcOperPbitTimer TimeTicks
  llcCcOperRejTimer TimeTicks
  llcCcOperBusyTimer TimeTicks
  llcCcOperInactTimer TimeTicks
  llcCcOperDelayAckCount Integer32
  llcCcOperDelayAckTimer TimeTicks
  llcCcOperNw Integer32
  llcCcOperWw INTEGER
  llcCcOperCreateTime TimeStamp
  llcCcOperLastModifyTime TimeStamp
  llcCcOperLastFailTime TimeStamp
  llcCcOperLastFailCause INTEGER
  llcCcOperLastFailFRMRInfo OCTET STRING
  llcCcOperLastWwCause INTEGER

LlcCcStatsEntry  
SEQUENCE    
  llcCcStatsLocalBusies Counter32
  llcCcStatsRemoteBusies Counter32
  llcCcStatsIFramesIn Counter32
  llcCcStatsIFramesOut Counter32
  llcCcStatsIOctetsIn Counter32
  llcCcStatsIOctetsOut Counter32
  llcCcStatsSFramesIn Counter32
  llcCcStatsSFramesOut Counter32
  llcCcStatsRetransmitsOut Counter32
  llcCcStatsREJsIn Counter32
  llcCcStatsREJsOut Counter32
  llcCcStatsWwCount Counter32

Defined Values

ciscoSnaLlcMIB 1.3.6.1.4.1.9.10.8
This is the MIB module for objects used to manage LLC devices.
MODULE-IDENTITY    

ciscoSnaLlcMIBObjects 1.3.6.1.4.1.9.10.8.1
OBJECT IDENTIFIER    

llcPortGroup 1.3.6.1.4.1.9.10.8.1.1
OBJECT IDENTIFIER    

llcSapGroup 1.3.6.1.4.1.9.10.8.1.2
OBJECT IDENTIFIER    

llcCcGroup 1.3.6.1.4.1.9.10.8.1.3
OBJECT IDENTIFIER    

llcPortAdminTable 1.3.6.1.4.1.9.10.8.1.1.1
This table contains objects that can be changed to manage an LLC port. Changing one of these parameters may take effect in the operating port immediately or may wait until the interface is restarted depending on the details of the implementation.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    LlcPortAdminEntry

llcPortAdminEntry 1.3.6.1.4.1.9.10.8.1.1.1.1
A list of configured values for an LLC port.
Status: current Access: not-accessible
OBJECT-TYPE    
  LlcPortAdminEntry  

llcPortVirtualIndex 1.3.6.1.4.1.9.10.8.1.1.1.1.1
This value represents a virtual LLC port. It is assigned by the agent. This value is set to 0 by the agent for interfaces identified by the ifIndex value that do not support virtual interfaces.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 0..65535  

llcPortAdminName 1.3.6.1.4.1.9.10.8.1.1.1.1.2
An octet string that defines the virtual port to which this interface is assigned. Its value shall be unique within the administered system. It must contain only ASCII printable characters. A write operation shall not take effect until the port is cycled inactive.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(1..8)  

llcPortAdminMaxSaps 1.3.6.1.4.1.9.10.8.1.1.1.1.3
This parameter specifies the maximum number of SAPs that can be defined for this port.
Status: current Access: read-write
OBJECT-TYPE    
  Gauge32  

llcPortAdminMaxCcs 1.3.6.1.4.1.9.10.8.1.1.1.1.4
This parameter specifies the maximum number of connection components that can be administratively defined for this port.
Status: current Access: read-write
OBJECT-TYPE    
  Gauge32  

llcPortAdminMaxPDUOctets 1.3.6.1.4.1.9.10.8.1.1.1.1.5
This object denotes the default maximum I PDU size, in octets, that LLCs on this port may send to their remote LLC partners. This count is referred to as 'N1' in the IEEE 802.2 specification [5]. This port default value may be overridden by a non-zero SAP default value in the llcSapAdminMaxIPDUOctetsSend object or by a non-zero value in the llcCcAdminMaxIPDUOctetsSend object. At connection setup, the remote LLC may send, using an XID frame, the maximum I PDU size which it is prepared to receive. If so, an implementation may choose to override the administered maximum PDU size with the dynamically learned value and should reflect this in the llcCcOperMaxIPDUOctetsSend object for the connection component. The I PDU size includes all octets in a frame, excluding framing characters, the MAC header and link header.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

llcPortAdminMaxUnackedIPDUsSend 1.3.6.1.4.1.9.10.8.1.1.1.1.6
This object denotes the default maximum consecutive unacknowledged I PDU frames that LLCs on this port may send to their remote LLC partners. This count is referred to as 'k' in the IEEE 802.2 specification [5]. This port default value may be overridden by a non-zero SAP default value in the llcSapAdminMaxUnackedIPDUsSend object or by a non-zero value in the llcCcAdminMaxUnackedIPDUsSend object. At connection setup, the remote LLC may send, using an XID frame, the maximum number of unacknowledged I PDUs which it is prepared to receive. If so, an implementation may choose to override the administered maximum number of unacknowledged PDUs with the dynamically learned value and should reflect this in the llcCcOperMaxUnackedIPDUsSend object for the connection component.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 1..127  

llcPortAdminMaxUnackedIPDUsRcv 1.3.6.1.4.1.9.10.8.1.1.1.1.7
This object denotes the default maximum number of unacknowledged I PDUs that LLCs on this port can expect to receive from their remote LLC partners. This count is referred to as 'k' in the IEEE 802.2 specification [5]. This port default value may be overridden by a non-zero SAP default value in the llcSapAdminMaxUnackedIPDUsRcv object or by a non-zero value in the llcCcAdminMaxUnackedIPDUsRcvd object. At connection setup, an implementation may choose to send this value to the remote LLC, using an XID frame.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 1..127  

llcPortAdminMaxRetransmits 1.3.6.1.4.1.9.10.8.1.1.1.1.8
This object denotes the default value for the maximum number of times which LLCs on this port shall retry a PDU following the expiration of the acknowledgement timer, the P-bit timer or the reject timer. When these retries are exhausted, the link shall be declared inactive. This count is referred to as 'N2' in the IEEE 802.2 specification [5]. This port default value may be overridden by a non-zero SAP default value in the llcSapAdminMaxretransmits object or by a non-zero value in the llcCcAdminMaxRetransmits object.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

llcPortAdminAckTimer 1.3.6.1.4.1.9.10.8.1.1.1.1.9
This object denotes the default value for the time interval during which the LLCs on this port shall expect to receive either: 1) an acknowledgement to one or more outstanding I PDUs. or 2) a response PDU to an unnumbered command PDU. The expiration of this timer shall cause the unacknowledged frames to be retransmitted (up to N2 times). For Implementations that only use a single 'T1' Value (ref. IBM Token-Ring Network technical reference Chapter 11). This object will be used to control/read the value. This port default value may be overridden by a non-zero value in the llcSapAdminAckTimer object or by a non-zero value in the llcCcAdminAckTimer object.
Status: current Access: read-write
OBJECT-TYPE    
  TimeTicks  

llcPortAdminPbitTimer 1.3.6.1.4.1.9.10.8.1.1.1.1.10
This object denotes the default value for the time interval during which the LLCs on this port shall expect to receive a PDU with the F bit set to '1' in response to a Type 2 command with the P bit set to '1'. The expiration of this timer shall cause the command with the poll bit to be retransmitted (up to N2 times). This port default value may be overridden by a non-zero SAP default value in the llcSapAdminPbitTimer object or by a non-zero value in the llcCcAdminPbitTimer object.
Status: current Access: read-write
OBJECT-TYPE    
  TimeTicks  

llcPortAdminRejTimer 1.3.6.1.4.1.9.10.8.1.1.1.1.11
This object denotes the default value for the time interval during which the LLCs on this port shall expect to receive a reply to a REJ PDU. The expiration of this timer shall cause the REJ PDU to be retransmitted (up to N2 times). This port default value may be overridden by a non-zero SAP default value in the llcSapAdminRejTimer object or by a non-zero value in the llcCcAdminRejTimer object.
Status: current Access: read-write
OBJECT-TYPE    
  TimeTicks  

llcPortAdminBusyTimer 1.3.6.1.4.1.9.10.8.1.1.1.1.12
This object denotes the default value for the time interval during which the LLCs on this port shall expect to receive an indication that a busy condition at the remote LLC has cleared. The expiration of this timer shall cause the link to be declared inactive. This port default value may be overridden by a non-zero SAP default value in the llcSapAdminBusyTimer object or by a non-zero value in the llcCcAdminBusyTimer object.
Status: current Access: read-write
OBJECT-TYPE    
  TimeTicks  

llcPortAdminInactTimer 1.3.6.1.4.1.9.10.8.1.1.1.1.13
This object denotes the default value for the time interval during which the LLCs on this port shall expect to receive any PDU from the remote LLC. This function is not described in the IEEE 802.2 specification [5]. It is listed in the IBM Token-Ring Network Architecture [6] Reference as the Ti parameter and is widely implemented. The expiration of this timer shall cause the local LLC to send a PDU to the remote LLC with the P bit set to '1'. The value for llcPortAdminInactTimer must be much greater than the value for llcPortAdminDelayAckTimer. This port default value may be overridden by a non-zero SAP default value in the llcSapAdminInactTimer object or by a non-zero value in the llcCcAdminInactTimer object. Any value for this object less than or equal to the acknowledgement timer shall mean that the timer is not used.
Status: current Access: read-write
OBJECT-TYPE    
  TimeTicks  

llcPortAdminDelayAckCount 1.3.6.1.4.1.9.10.8.1.1.1.1.14
This object denotes the default value for the maximum number of consecutive I PDUs which the LLCs on this port shall receive during the interval defined by llcCcOperDelayTimertime without sending an immediate acknowledgement. This must be less than or equal to the value of llcCcOperMaxUnackIPDURcv. This function is not described in the IEEE 802.2 specification [5]. It is listed in the IBM Token-Ring Network Architecture Reference [6] as the N3 parameter and is widely implemented. This port default value may be overridden by a non-zero SAP default value in the llcSapAdminDelayAckCount object or by a non-zero value in the llcCcAdminDelayCount object. A value of one indicates that acknowledgments will be sent immediately and that the value of llcPortAdminDelayAckTimer shall be ignored.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

llcPortAdminDelayAckTimer 1.3.6.1.4.1.9.10.8.1.1.1.1.15
This object denotes the default value for the time interval during which the LLCs on this port shall delay acknowledgment of one or more I PDUs (up to the value of llcCcOperDelayAckCount). This function is not described in the IEEE 802.2 specification [5]. It is listed in the IBM Token-Ring Network Architecture Reference [6] as the T2 parameter and is widely implemented. The expiration of this timer shall cause the local LLC to acknowledge all unacknowledged I PDUs. This object is associated with the llcSapAdminDelayAckCount object and is only defined if that object has a value greater than one.
Status: current Access: read-write
OBJECT-TYPE    
  TimeTicks  

llcPortAdminNw 1.3.6.1.4.1.9.10.8.1.1.1.1.16
This object denotes the default value for the number of IPDUs that must be acknowledged before the working window size (Ww) can be incremented by 1 when the working window is not equal to the maximum transmit window size (TW). It controls the gradual incrementing of Ww in congestion situations. This function is not described in the IEEE 802.2 specification [5]. However, it is listed in the IBM Token-Ring Network Architecture Reference [6] as the Nw parameter and is widely implemented. This port default value may be overridden by a non-zero SAP default value in the llcSapAdminNw object.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

llcPortOperTable 1.3.6.1.4.1.9.10.8.1.1.2
This table contains current LLC port parameters. Many of these objects have corresponding objects in the llcPortAdminTable.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    LlcPortOperEntry

llcPortOperEntry 1.3.6.1.4.1.9.10.8.1.1.2.1
Currently set parameters for a specific LLC port.
Status: current Access: not-accessible
OBJECT-TYPE    
  LlcPortOperEntry  

llcPortOperMacAddress 1.3.6.1.4.1.9.10.8.1.1.2.1.1
This is the MAC Address for this local port.
Status: current Access: read-only
OBJECT-TYPE    
  MacAddress  

llcPortOperNumSaps 1.3.6.1.4.1.9.10.8.1.1.2.1.2
This object defines the number of SAPs on this port that are currently enabled. In other words, this object is a count of the number of instances of llcSapOperEntry that have a llcSapOperStatus value of 'active(2)'.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

llcPortOperHiWaterNumSaps 1.3.6.1.4.1.9.10.8.1.1.2.1.3
This object reflects the highest number of SAPs active on this Port simultaneously. In other words, this object is a count of the number of instances of llcSapOperEntry on this Port.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

llcPortOperSimRim 1.3.6.1.4.1.9.10.8.1.1.2.1.4
This object reflects support for transmission and receipt of SIM and RIM control frames for this port. SIM and RIM are not defined in the ANSI/IEEE 802.2 specification [5] nor in the IBM Token Ring Architecture Reference [6]. These control frames are used for the remote program load of IBM communications processors.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

llcPortOperLastModifyTime 1.3.6.1.4.1.9.10.8.1.1.2.1.5
This object describes the value of sysUpTime when this port definition was last modified. If the port has not been modified, then this value shall be zero.
Status: current Access: read-only
OBJECT-TYPE    
  TimeStamp  

llcPortStatsTable 1.3.6.1.4.1.9.10.8.1.1.3
Each entry in this table contains statistics for a specific LLC port.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    LlcPortStatsEntry

llcPortStatsEntry 1.3.6.1.4.1.9.10.8.1.1.3.1
A list of statistics for an LLC port.
Status: current Access: not-accessible
OBJECT-TYPE    
  LlcPortStatsEntry  

llcPortStatsPDUsIn 1.3.6.1.4.1.9.10.8.1.1.3.1.1
This object reflects the total number of PDUs that have been received on this port. This object is initialized to zero when the port is created.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

llcPortStatsPDUsOut 1.3.6.1.4.1.9.10.8.1.1.3.1.2
This object reflects the total number of PDUs that have been transmitted on this port. This object is initialized to zero when the port is created.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

llcPortStatsOctetsIn 1.3.6.1.4.1.9.10.8.1.1.3.1.3
This object reflects the total octets received on this port. This object is initialized to zero when the port is created.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

llcPortStatsOctetsOut 1.3.6.1.4.1.9.10.8.1.1.3.1.4
This object reflects the total octets transmitted on this port. This object is initialized to zero when the port is created.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

llcPortStatsTESTCommandsIn 1.3.6.1.4.1.9.10.8.1.1.3.1.5
This object reflects the total number of TEST commands received on this port.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

llcPortStatsTESTResponsesOut 1.3.6.1.4.1.9.10.8.1.1.3.1.6
This object reflects the total number of TEST responses transmitted on this port in response to TEST commands received.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

llcPortStatsLocalBusies 1.3.6.1.4.1.9.10.8.1.1.3.1.7
This object reflects the total number of times that the local connection components on this port have entered a busy state (RNR). This object is initialized to zero when the port is created.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

llcPortStatsUnknownSaps 1.3.6.1.4.1.9.10.8.1.1.3.1.8
This object reflects the total number of times that a connection attempt, from a remote LLC station, for an unknown SAP was detected on this port.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

llcSapAdminTable 1.3.6.1.4.1.9.10.8.1.2.1
This table contains objects that can be changed to manage a local SAP. Changing one of these parameters may take effect in the operating CC immediately or may wait until the interface is restarted depending on the details of the implementation.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    LlcSapAdminEntry

llcSapAdminEntry 1.3.6.1.4.1.9.10.8.1.2.1.1
A list of configured values for a local SAP.
Status: current Access: not-accessible
OBJECT-TYPE    
  LlcSapAdminEntry  

llcSapNumber 1.3.6.1.4.1.9.10.8.1.2.1.1.1
The address of this local SAP.
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 1..255  

llcSapAdminMaxPDUOctets 1.3.6.1.4.1.9.10.8.1.2.1.1.2
This object denotes the default maximum I PDU size, in octets, that LLCs on this SAP may send to their remote connection component partners. This count is referred to as 'N1' in the IEEE 802.2 specification [5]. A zero value for this object indicates that the port default, llcPortAdminMaxIPDUOctetsSend, shall be used as the SAP default. This SAP default value may be overridden by a non-zero value in the llcCcAdminMaxIPDUOctetsSend object. At connection setup, the remote LLC may send, using an XID frame, the maximum I PDU size which it is prepared to receive. If so, an implementation may choose to override the administered maximum PDU size with the dynamically learned value and should reflect this in the llcCcOperMaxIPDUOctetsSend object for the connection component. The I PDU size includes all octets in a frame, excluding framing characters, the MAC header and link header.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

llcSapAdminMaxUnackedIPDUsSend 1.3.6.1.4.1.9.10.8.1.2.1.1.3
This object denotes the default maximum consecutive unacknowledged I PDU frames that LLCs on this SAP may send to their remote LLC partners. This count is referred to as 'k' in the IEEE 802.2 specification [5]. A zero value for this object indicates that the port default, llcPortAdminMaxUnackedIPDUsSend, shall be used as the SAP default. This SAP default value may be overridden by a non-zero value in the llcCcAdminMaxUnackedIPDUsSend object. At connection setup, the remote LLC may send, using an XID frame, the maximum number of unacknowledged I PDUs which it is prepared to receive. If so, an implementation may choose to override the administered maximum number of unacknowledged PDUs with the dynamically learned value and should reflect this in the llcCcOperMaxUnackedIPDUsSend object for the connection component.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..127  

llcSapAdminMaxUnackedIPDUsRcv 1.3.6.1.4.1.9.10.8.1.2.1.1.4
This object denotes the default maximum number of unacknowledged I PDUs that LLCs on this SAP can expect to receive from their remote LLC partners. This count is referred to as 'k' in the IEEE 802.2 specification [5]. A zero value for this object indicates that the port default, llcPortAdminMaxUnackedIPDUsRcv, shall be used as the SAP default. This SAP default value may be overridden by a non-zero value in the llcCcAdminMaxUnackedIPDUsRcv object. At connection setup, an implementation may choose to send this value to the remote LLC, using an XID frame.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..127  

llcSapAdminMaxRetransmits 1.3.6.1.4.1.9.10.8.1.2.1.1.5
This object denotes the default value for the maximum number of times that LLCs on this SAP shall retry PDUs following the expiration of the acknowledgement timer, the P-bit timer or the reject timer. When these retries are exhausted, the link shall be declared inactive. This count is referred to as 'N2' in the IEEE 802.2 specification [5]. A zero value for this object indicates that the port default, llcPortAdminMaxRetransmits, shall be used as the SAP default. This SAP default value may be overridden by a non-zero value in the llcCcAdminMaxRetransmits.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

llcSapAdminAckTimer 1.3.6.1.4.1.9.10.8.1.2.1.1.6
This object denotes the default value for the time interval during which the LLCs on this SAP shall expect to receive either: 1) an acknowledgement to one or more outstanding I PDUs. or 2) a response PDU to an unnumbered command PDU. The expiration of this timer shall cause the frame unacknowledged frames to be retransmitted (up to N2 times). A zero value for this object indicates that the port default, llcPortAdminAckTimer, shall be used as the SAP default. This SAP default value may be overridden by a non-zero value in the llcCcAdminAckTimer.
Status: current Access: read-write
OBJECT-TYPE    
  TimeTicks  

llcSapAdminPbitTimer 1.3.6.1.4.1.9.10.8.1.2.1.1.7
This object denotes the default value for the time interval during which the LLCs on this port shall expect to receive a PDU with the F bit set to '1' in response to a Type 2 command with the P bit set to '1'. The expiration of this timer shall cause the REJ PDU to be retransmitted (up to N2 times). A zero value for this object indicates that the port default, llcPortAdminPbitTimer, shall be used as the SAP default. This SAP default value may be overridden by a non-zero value in the llcCcAdminPbitTimer.
Status: current Access: read-write
OBJECT-TYPE    
  TimeTicks  

llcSapAdminRejTimer 1.3.6.1.4.1.9.10.8.1.2.1.1.8
This object denotes the default value for the time interval during which the LLCs on this SAP shall expect to receive a reply to a REJ PDU. The expiration of this timer shall cause the REJ PDU to be retransmitted (up to N2 times). A zero value for this object indicates that the port default, llcPortAdminRejTimer, shall be used as the SAP default. This SAP default value may be overridden by a non-zero value in the llcCcAdminRejTimer.
Status: current Access: read-write
OBJECT-TYPE    
  TimeTicks  

llcSapAdminBusyTimer 1.3.6.1.4.1.9.10.8.1.2.1.1.9
This object denotes the default value for the time interval during which the LLCs on this SAP shall expect to receive an indication that a busy condition at the remote LLC has cleared. The expiration of this timer shall cause the link to be declared inactive. A zero value for this object indicates that the port default, llcPortAdminBusyTimer, shall be used as the SAP default. This SAP default value may be overridden by a non-zero value in the llcCcAdminBusyTimer.
Status: current Access: read-write
OBJECT-TYPE    
  TimeTicks  

llcSapAdminInactTimer 1.3.6.1.4.1.9.10.8.1.2.1.1.10
This object denotes the default value for the time interval during which the LLCs on this SAP shall expect to receive any PDU from the remote LLC. This function is not described in the IEEE 802.2 specification [5] but is widely implemented. The expiration of this timer shall cause the local LLC to send a PDU to the remote LLC with the P bit set to '1'. A zero value for this object indicates that the port default, llcPortAdminInactTimer, shall be used as the SAP default. This SAP default value may be overridden by a non-zero value in the llcCcAdminInactTimer. Any value for this object less than or equal to the acknowledgement timer shall mean that the timer is not used.
Status: current Access: read-write
OBJECT-TYPE    
  TimeTicks  

llcSapAdminDelayAckCount 1.3.6.1.4.1.9.10.8.1.2.1.1.11
This object denotes the default value for the maximum number of consecutive I PDUs which the LLCs on this SAP shall receive during the interval defined by llcCcOperDelayTimer without sending an immediate acknowledgement. This must be less than or equal to the value of llcCcOperMaxUnackIPDURcv. This function is not described in the IEEE 802.2 specification [5] but is widely implemented. A zero value for this object indicates that the port default, llcPortAdminDelayAck, shall be used as the SAP default. This SAP default value may be overridden by a non-zero value in the llcCcAdminDelayAckCount. A value of one indicates that acknowledgments will be sent immediately and that the value of llcSapAdminDelayAckTimer shall be ignored.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

llcSapAdminDelayAckTimer 1.3.6.1.4.1.9.10.8.1.2.1.1.12
This object denotes the default value for the time interval during which the LLCs on this SAP shall delay acknowledgment of one or more I PDUs (up to the value of llcCcOperDelayAckCount). This function is not described in the IEEE 802.2 specification [5]. It is listed in the IBM Token-Ring Network Architecture Reference [6] as the T2 parameter and is widely implemented. The expiration of this timer shall cause the local LLC to acknowledge all unacknowledged I PDUs. This object is associated with the llcSapAdminDelayAckCount object and is only defined if that object has a value greater than one.
Status: current Access: read-write
OBJECT-TYPE    
  TimeTicks  

llcSapAdminNw 1.3.6.1.4.1.9.10.8.1.2.1.1.13
This object denotes the default value for the number of IPDUs that must be acknowledged before the working window size (Ww) can be incremented by 1 when the working window is not equal to the maximum transmit window size (TW). It controls the gradual incrementing of Ww in congestion situations. This function is not described in the IEEE 802.2 specification [5]. However, it is listed in the IBM Token-Ring Network Architecture Reference [6] as the Nw parameter and is widely implemented. This SAP default value may be overridden by a non-zero Cc default value in the llcCcAdminNw object.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

llcSapOperTable 1.3.6.1.4.1.9.10.8.1.2.2
This table contains objects that reflect the current operational parameters of a local SAP.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    LlcSapOperEntry

llcSapOperEntry 1.3.6.1.4.1.9.10.8.1.2.2.1
A list of configured values for a local SAP.
Status: current Access: not-accessible
OBJECT-TYPE    
  LlcSapOperEntry  

llcSapOperStatus 1.3.6.1.4.1.9.10.8.1.2.2.1.1
This parameter describes the actual state of this local SAP.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER inactive(1), active(2)  

llcSapOperNumCcs 1.3.6.1.4.1.9.10.8.1.2.2.1.2
This object defines the number of connection components on this SAP that are currently in one of the 'connected' states. In other words, this object is a count of the number of instances of llcCcOperEntry that have a llcCcOperState value greater than or equal to 'normal(3)'.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

llcSapOperHiWaterNumCcs 1.3.6.1.4.1.9.10.8.1.2.2.1.3
This object reflects the highest number of connection components on this SAP simultaneously in one of the 'connected' states. In other words, this object is a count of the number of instances of llcCcOperEntry that have a llcCcOperState value greater than or equal to 'normal(3)' concurrently on this SAP.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

llcSapOperLlc2Support 1.3.6.1.4.1.9.10.8.1.2.2.1.4
This parameter describes whether or not the LLC implementation supports LLC2 connection components.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

llcSapStatsTable 1.3.6.1.4.1.9.10.8.1.2.3
This table contains objects that reflect the current operational parameters of a local SAP.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    LlcSapStatsEntry

llcSapStatsEntry 1.3.6.1.4.1.9.10.8.1.2.3.1
A list of configured values for a local SAP.
Status: current Access: not-accessible
OBJECT-TYPE    
  LlcSapStatsEntry  

llcSapStatsLocalBusies 1.3.6.1.4.1.9.10.8.1.2.3.1.1
This object reflects the total number of times that the local connection components on this SAP have entered a busy state (RNR). This object is initialized to zero when the SAP is created.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

llcSapStatsRemoteBusies 1.3.6.1.4.1.9.10.8.1.2.3.1.2
This object reflects the total number of times that the adjacent (i.e. remote) connection components on this SAP have entered a busy state (RNR). This object is initialized to zero when the SAP is created.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

llcSapStatsIFramesIn 1.3.6.1.4.1.9.10.8.1.2.3.1.3
This object reflects the total number of I-Frames that have been received by connection components on this SAP. This object is initialized to zero when the SAP is created.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

llcSapStatsIFramesOut 1.3.6.1.4.1.9.10.8.1.2.3.1.4
This object reflects the total number of I-Frames that have been transmitted by connection components on this SAP. This object is initialized to zero when the SAP is created.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

llcSapStatsIOctetsIn 1.3.6.1.4.1.9.10.8.1.2.3.1.5
This object reflects the total octets received from adjacent connection components on this SAP. This object covers the address, control, and information field of I-Frames only. This object is initialized to zero when the SAP is created.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

llcSapStatsIOctetsOut 1.3.6.1.4.1.9.10.8.1.2.3.1.6
This object reflects the total octets transmitted to adjacent connection components on this SAP. This object covers the address, control, and information field of I-Frames only. This object is initialized to zero when the SAP is created.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

llcSapStatsSFramesIn 1.3.6.1.4.1.9.10.8.1.2.3.1.7
This object reflects the total number of S-Frames that have been received by connection components on this SAP. This object is initialized to zero when the SAP is created. Note - the ratio of the number of I-Frames to S-Frames might serve as a measure of link efficiency and, for instance, could be used to tune the acknowledgement timer.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

llcSapStatsSFramesOut 1.3.6.1.4.1.9.10.8.1.2.3.1.8
This object reflects the total number of S-Frames that have been transmitted by connection components on this SAP. This object is initialized to zero when the SAP is created. Note - the ratio of the number of I-Frames to S-Frames might serve as a measure of link efficiency and, for instance, could be used to tune the acknowledgement timer.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

llcSapStatsRetransmitsOut 1.3.6.1.4.1.9.10.8.1.2.3.1.9
This object reflects the total number of I-Frames retransmitted by all local connection components on this SAP. This object is initialized to zero when the SAP is created.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

llcSapStatsREJsIn 1.3.6.1.4.1.9.10.8.1.2.3.1.10
This object reflects the total REJ frames received from all adjacent LLC connection components on this SAP since it was created.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

llcSapStatsREJsOut 1.3.6.1.4.1.9.10.8.1.2.3.1.11
This object reflects the total REJ frames transmitted to an adjacent LLC connection components on this SAP since it was created.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

llcSapStatsWwCount 1.3.6.1.4.1.9.10.8.1.2.3.1.12
This object reflects the total number of times, since this SAP was created, that the dynamic window algorithm has been invoked to reduce the value of Ww on any of the connection components of this SAP. This object is initialized to zero when the SAP is created. This function is not described in the IEEE 802.2 specification [5], but is widely implemented.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

llcSapStatsTESTCommandsIn 1.3.6.1.4.1.9.10.8.1.2.3.1.13
This object denotes the number of TEST commands this SAP has received and is a measure of the number of stations in the network trying to connect up. This object is initialized to zero when the SAP is created.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

llcSapStatsTESTCommandsOut 1.3.6.1.4.1.9.10.8.1.2.3.1.14
This object denotes the number of TEST commands this SAP has sent and is a measure of the number of other stations we are trying to connect to. This object is initialized to zero when the SAP is created.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

llcSapStatsTESTResponsesIn 1.3.6.1.4.1.9.10.8.1.2.3.1.15
This object denotes the number of TEST responses this SAP has received and is a measure of the number of stations in the network responding to TEST commands this SAP has sent. This object is initialized to zero when the SAP is created.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

llcSapStatsTESTResponsesOut 1.3.6.1.4.1.9.10.8.1.2.3.1.16
This object denotes the number of TEST responses this SAP has sent and is a measure of the number of other stations trying to connect to this SAP. This object is initialized to zero when the SAP is created.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

llcSapStatsXIDCommandsIn 1.3.6.1.4.1.9.10.8.1.2.3.1.17
This object denotes the number of XID commands this SAP has received and is a measure of the number of stations in the network trying to connect to this SAP. This object is a count of all XIDs, including SNA XID, IEEE XID, null XID, and non-activation XIDs. This object is initialized to zero when the SAP is created.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

llcSapStatsXIDCommandsOut 1.3.6.1.4.1.9.10.8.1.2.3.1.18
This object denotes the number of XID commands this SAP has sent and is a measure of the number of other stations this SAP is trying to connect to. This object is a count of all XIDs, including SNA XID, IEEE XID, null XID, and non-activation XIDs. This object is initialized to zero when the SAP is created.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

llcSapStatsXIDResponsesIn 1.3.6.1.4.1.9.10.8.1.2.3.1.19
This object denotes the number of XID responses this SAP has received and is a measure of the number of stations in the network responding to TEST commands this SAP has sent. This object is a count of all XIDs, including SNA XID, IEEE XID, null XID, and non-activation XIDs. This object is initialized to zero when the SAP is created.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

llcSapStatsXIDResponsesOut 1.3.6.1.4.1.9.10.8.1.2.3.1.20
This object denotes the number of XID responses this SAP has sent and is a measure of the number of other stations trying to connect to this SAP. This object is a count of all XIDs, including SNA XID, IEEE XID, null XID, and non-activation XIDs. This object is initialized to zero when the SAP is created.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

llcSapStatsUIFramesIn 1.3.6.1.4.1.9.10.8.1.2.3.1.21
This object reflects the total number of unnumbered information (UI) frames received on a local SAP.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

llcSapStatsUIFramesOut 1.3.6.1.4.1.9.10.8.1.2.3.1.22
This object reflects the total number of unnumbered information (UI) frames sent on a local SAP.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

llcSapStatsUIOctetsIn 1.3.6.1.4.1.9.10.8.1.2.3.1.23
This object reflects the total octets received from adjacent connection components on this SAP. This object covers the address, control, and information field of UI-Frames only. This object is initialized to zero when the SAP is created.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

llcSapStatsUIOctetsOut 1.3.6.1.4.1.9.10.8.1.2.3.1.24
This object reflects the total octets transmitted to adjacent connection components on this SAP. This object covers the address, control, and information field of UI-Frames only. This object is initialized to zero when the SAP is created.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

llcSapStatsConnectOk 1.3.6.1.4.1.9.10.8.1.2.3.1.25
This object reflects the total number of successful connections that have been established on this SAP since the SAP was created. A successful connection is indicated by a successful SABME/UA exchange.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

llcSapStatsConnectFail 1.3.6.1.4.1.9.10.8.1.2.3.1.26
This object reflects the total number of unsuccessful connections that have been attempted on this SAP since the SAP was created. An unsuccessful connection attempt is indicated by a SABME/DM exchange or a SABME/timeout.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

llcSapStatsDisconnect 1.3.6.1.4.1.9.10.8.1.2.3.1.27
This object reflects the total number of normal disconnections that have been performed on this SAP since the SAP was created. A normal disconnection is indicated by a successful DISC/UA exchange or merely a DISC sent or received.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

llcSapStatsDisconnectFRMRSend 1.3.6.1.4.1.9.10.8.1.2.3.1.28
This object reflects the total number of abnormal disconnections (resulting from a FRMR being sent) that have been performed on this SAP since the SAP was created.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

llcSapStatsDisconnectFRMRRcv 1.3.6.1.4.1.9.10.8.1.2.3.1.29
This object reflects the total number of abnormal disconnections (resulting from a FRMR being received) that have been performed on this SAP since the SAP was created.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

llcSapStatsDisconnectTimer 1.3.6.1.4.1.9.10.8.1.2.3.1.30
This object reflects the total number of abnormal disconnections (resulting from a timer expiration) that have been performed on this SAP since the SAP was created.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

llcSapStatsDMsInABM 1.3.6.1.4.1.9.10.8.1.2.3.1.31
This object reflects the total number of Disconnect Mode responses that have been received for CCs in ABM mode on this SAP since the SAP was created.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

llcSapStatsSABMEsInABM 1.3.6.1.4.1.9.10.8.1.2.3.1.32
This object reflects the total number of SABMEs that have been received for CCs in already in ABM mode on this SAP since the SAP was created.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

llcCcAdminTable 1.3.6.1.4.1.9.10.8.1.3.1
This table contains objects that can be changed to manage an LLC connection component. Changing one of these parameters may take effect in the operating link immediately or may wait until the link is restarted depending on the details of the implementation. The entries in llcCcAdminTable can be created either by an agent or a management station. The management station can create an entry in llcCcAdminTable by setting the appropriate value in llcCcAdminRowStatus. Most of the objects in this read-create table have corresponding read-only objects in the llcCcOperTable that reflect the current operating value. The operating values may be different from these configured values if changed by XID negotiation or if a configured parameter was changed after the link was started.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    LlcCcAdminEntry

llcCcAdminEntry 1.3.6.1.4.1.9.10.8.1.3.1.1
A list of configured values for an LLC connection component.
Status: current Access: not-accessible
OBJECT-TYPE    
  LlcCcAdminEntry  

llcCcRMac 1.3.6.1.4.1.9.10.8.1.3.1.1.1
This value is the remote MAC address for this Connection Component. This value is provided by the SNMP agent.
Status: current Access: not-accessible
OBJECT-TYPE    
  MacAddress  

llcCcRSap 1.3.6.1.4.1.9.10.8.1.3.1.1.2
This value is the address of the remote SAP for this Connection Component. This value is provided by the SNMP agent.
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 1..255  

llcCcAdminBounce 1.3.6.1.4.1.9.10.8.1.3.1.1.3
This object controls the resetting of the connection component. Setting this value to yes(2) results in the connection component being reset, llcCcOperState transitioning to a value of aDm(1), and the value of llcCcAdminBounce being set back to no(1).
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

llcCcAdminMaxPDUOctets 1.3.6.1.4.1.9.10.8.1.3.1.1.4
This object denotes the maximum I PDU size, in octets, that this LLC SAP may send to its remote connection component partner. This count is referred to as 'N1' in the IEEE 802.2 specification [5]. This object contains an administrative value which will be applied the next time this connection is established. A zero value for this object indicates that the SAP default, llcSapAdminMaxIPDUOctetsSend, shall be used. At connection setup, the remote LLC may send, using an XID frame, the maximum I PDU size which it is prepared to receive. If so, an implementation may choose to override the administered maximum PDU size with the dynamically learned value and should reflect this in the llcCcOperMaxIPDUOctetsSend object for the connection component. The I PDU size includes all octets in a frame, excluding framing characters, the MAC header and link header.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32  

llcCcAdminMaxUnackedIPDUsSend 1.3.6.1.4.1.9.10.8.1.3.1.1.5
This object denotes the maximum consecutive unacknowledged I PDU frames that this LLC may send to its remote LLC partner. This count is referred to as 'k' in the IEEE 802.2 specification [5]. This object contains an administrative value which will be applied the next time this connection is established. A zero value for this object indicates that the SAP default, llcSapAdminMaxUnackedIPDUsSend, shall be used. At connection setup, the remote LLC may send, using an XID frame, the maximum number of unacknowledged I PDUs which it is prepared to receive. If so, an implementation may choose to override the administered maximum number of unacknowledged PDUs with the dynamically learned value and should reflect this in the llcCcOperMaxUnackedIPDUsSend object for the connection component.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER 0..127  

llcCcAdminMaxUnackedIPDUsRcv 1.3.6.1.4.1.9.10.8.1.3.1.1.6
This object denotes the maximum number of unacknowledged I PDUs that this LLC can expect to receive from its remote LLC partner. This count is referred to as 'k' in the IEEE 802.2 specification [5]. This object contains an administrative value which will be applied the next time this connection is established. A zero value for this object indicates that the SAP default, llcSapAdminMaxUnackedIPDUsRcv, shall be used. At connection setup, an implementation may choose to send this value to the remote LLC, using an XID frame.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER 0..127  

llcCcAdminMaxRetransmits 1.3.6.1.4.1.9.10.8.1.3.1.1.7
This object denotes the value for the maximum number of times that this LLC shall retry PDUs following the expiration of the acknowledgement timer, the P-bit timer or the reject timer. When these retries are exhausted, the link shall be declared inactive. This count is referred to as 'N2' in the IEEE 802.2 specification [5]. This object contains an administrative value which will be applied the next time this connection is established. A zero value for this object indicates that the SAP default, llcSapAdminMaxRetransmits, shall be used.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32  

llcCcAdminAckTimer 1.3.6.1.4.1.9.10.8.1.3.1.1.8
This object denotes the value for the time interval during which this LLC shall expect to receive either: 1) an acknowledgement to one or more outstanding I PDUs. or 2) a response PDU to an unnumbered command PDU. The expiration of this timer shall cause the frame unacknowledged frames to be retransmitted (up to N2 times). This object contains an administrative value which will be applied the next time this connection is established. A zero value for this object indicates that the SAP default, llcSapAdminAckTimer, shall be used.
Status: current Access: read-create
OBJECT-TYPE    
  TimeTicks  

llcCcAdminPbitTimer 1.3.6.1.4.1.9.10.8.1.3.1.1.9
This object denotes the value for the time interval during which this LLC shall expect to receive a PDU with the F bit set to '1' in response to a Type 2 command with the P bit set to '1'. The expiration of this timer shall cause the REJ PDU to be retransmitted (up to N2 times). This object contains an administrative value which will be applied the next time this connection is established. A zero value for this object indicates that the SAP default, llcSapAdminPbitTimer, shall be used.
Status: current Access: read-create
OBJECT-TYPE    
  TimeTicks  

llcCcAdminRejTimer 1.3.6.1.4.1.9.10.8.1.3.1.1.10
This object denotes the value for the time interval during which this LLC shall expect to receive a reply to a REJ PDU. The expiration of this timer shall cause the REJ PDU to be retransmitted (up to N2 times). This object contains an administrative value which will be applied the next time this connection is established. A zero value for this object indicates that the SAP default, llcSapAdminRejTimer, shall be used.
Status: current Access: read-create
OBJECT-TYPE    
  TimeTicks  

llcCcAdminBusyTimer 1.3.6.1.4.1.9.10.8.1.3.1.1.11
This object denotes the value for the time interval during which this LLC shall expect to receive an indication that a busy condition at the remote LLC has cleared. The expiration of this timer shall cause the link to be declared inactive. This object contains an administrative value which will be applied the next time this connection is established. A zero value for this object indicates that the SAP default, llcSapAdminBusyTimer, shall be used.
Status: current Access: read-create
OBJECT-TYPE    
  TimeTicks  

llcCcAdminInactTimer 1.3.6.1.4.1.9.10.8.1.3.1.1.12
This object denotes the value for the time interval during which this LLC shall expect to receive any PDU from the remote LLC. This function is not described in the IEEE 802.2 specification [5] but is widely implemented. The expiration of this timer shall cause the local LLC to send a PDU to the remote LLC with the P bit set to '1'. This object contains an administrative value which will be applied the next time this connection is established. A zero value for this object indicates that the SAP default, llcSapAdminInactTimer, shall be used. Any value for this object less than or equal to the acknowledgement timer shall mean that the timer is not used.
Status: current Access: read-create
OBJECT-TYPE    
  TimeTicks  

llcCcAdminDelayAckCount 1.3.6.1.4.1.9.10.8.1.3.1.1.13
This object denotes the value for the maximum number of consecutive I PDUs which this LLC shall receive during the interval defined by llcCcOperDelayTimer without sending an immediate acknowledgement. This must be less than or equal to the value of llcCcOperMaxUnackIPDURcv. This function is not described in the IEEE 802.2 specification [5] but is widely implemented. This object contains an administrative value which will be applied the next time this connection is established. A zero value for this object indicates that the SAP default, llcSapAdminDelayAck, shall be used. A value of one indicates that acknowledgments will be sent immediately and that the value of llcCcAdminDelayAckTimer shall be ignored.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32  

llcCcAdminDelayAckTimer 1.3.6.1.4.1.9.10.8.1.3.1.1.14
This object denotes the value for the time interval during which this LLC shall delay acknowledgment of one or more I PDUs (up to the value of llcCcOperDelayAckCount). This function is not described in the IEEE 802.2 specification [5]. It is listed in the IBM Token-Ring Network Architecture Reference [6] as the T2 parameter and is widely implemented. The expiration of this timer shall cause the local LLC to acknowledge all unacknowledged I PDUs. This object contains an administrative value which will be applied the next time this connection is established. This object is associated with the llcCcAdminDelayAckCount object and is only defined if that object has a value greater than one.
Status: current Access: read-create
OBJECT-TYPE    
  TimeTicks  

llcCcAdminNw 1.3.6.1.4.1.9.10.8.1.3.1.1.15
This object denotes the value for the number of IPDUs that must be acknowledged before the working window size (Ww) can be incremented by 1 when the working window is not equal to the maximum transmit window size (TW). It controls the gradual incrementing of Ww in congestion situations. This function is not described in the IEEE 802.2 specification [5]. However, it is listed in the IBM Token-Ring Network Architecture Reference [6] as the Nw parameter and is widely implemented.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32  

llcCcAdminRowStatus 1.3.6.1.4.1.9.10.8.1.3.1.1.16
This object is used by a management station to create or delete the row entry in llcCcAdminTable following the RowStatus textual convention. Upon successful creation of the row, an agent automatically creates a corresponding entry in the llcCcOperTable with llcCcOperState equal to 'aDM (1)'.
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

llcCcOperTable 1.3.6.1.4.1.9.10.8.1.3.2
This table contains current LLC link parameters. Many of these objects have corresponding objects in the llcCcAdminTable.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    LlcCcOperEntry

llcCcOperEntry 1.3.6.1.4.1.9.10.8.1.3.2.1
A list of status and control values for an LLC connection component.
Status: current Access: not-accessible
OBJECT-TYPE    
  LlcCcOperEntry  

llcCcOperState 1.3.6.1.4.1.9.10.8.1.3.2.1.1
This object describes the operational state of the LLC connection. If the connection component is disabled, llcCcOperState will transition to aDM(1). If the connection component is enabled, llcCcOperState will transition to normal(3).
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER aDM(1), setup(2), normal(3), busy(4), reject(5), await(6), awaitBusy(7), awaitReject(8), dConn(9), reset(10), error(11), conn(12), resetCheck(13), resetWait(14)  

llcCcOperMaxIPDUOctetsSend 1.3.6.1.4.1.9.10.8.1.3.2.1.2
This object denotes the maximum I PDU size, in octets, that this LLC SAP may send to its remote connection component partner. This count is referred to as 'N1' in the IEEE 802.2 specification [5]. At connection setup, the remote LLC may send, using an XID frame, the maximum I PDU size which it is prepared to receive. If so, an implementation may choose to override the administered maximum PDU size with the dynamically learned value and should reflect that in this object. The I PDU size includes all octets in a frame, excluding framing characters, the MAC header and link header.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

llcCcOperMaxIPDUOctetsRcv 1.3.6.1.4.1.9.10.8.1.3.2.1.3
This object denotes the maximum I PDU size, in octets, that this LLC can expect to receive from its remote LLC partner. This count is referred to as 'N1' in the IEEE 802.2 specification [5] The I PDU size includes all octets in a frame with the exception of the framing characters, the MAC header and the link header.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

llcCcOperMaxUnackedIPDUsSend 1.3.6.1.4.1.9.10.8.1.3.2.1.4
This object denotes the maximum consecutive unacknowledged I PDU frames that this LLC may send to its remote LLC partner. This count is referred to as 'k' in the IEEE 802.2 specification [5]. At connection setup, the remote LLC may send, using an XID frame, the maximum number of unacknowledged I PDUs which it is prepared to receive. If so, an implementation may choose to override the administered maximum number of unacknowledged PDUs with the dynamically learned value and should reflect that in this object.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 1..127  

llcCcOperMaxUnackedIPDUsRcv 1.3.6.1.4.1.9.10.8.1.3.2.1.5
This object denotes the maximum number of unacknowledged I PDUs that this LLC can expect to receive from its remote LLC partner. This count is referred to as 'k' in the IEEE 802.2 specification [5].
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 1..127  

llcCcOperMaxRetransmits 1.3.6.1.4.1.9.10.8.1.3.2.1.6
This object denotes the value for the maximum number of times that this LLC shall retry PDUs following the expiration of the acknowledgement timer, the P-bit timer or the reject timer. When these retries are exhausted, the link shall be declared inactive. This count is referred to as 'N2' in the IEEE 802.2 specification [5].
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

llcCcOperAckTimer 1.3.6.1.4.1.9.10.8.1.3.2.1.7
This object denotes the value for the time interval during which this LLC shall expect to receive either: 1) an acknowledgement to one or more outstanding I PDUs. or 2) a response PDU to an unnumbered command PDU. The expiration of this timer shall cause the frame unacknowledged frames to be retransmitted (up to N2 times).
Status: current Access: read-only
OBJECT-TYPE    
  TimeTicks  

llcCcOperPbitTimer 1.3.6.1.4.1.9.10.8.1.3.2.1.8
This object denotes the value for the time interval during which this LLC shall expect to receive a PDU with the F bit set to '1' in response to a Type 2 command with the P bit set to '1'. The expiration of this timer shall cause the REJ PDU to be retransmitted (up to N2 times).
Status: current Access: read-only
OBJECT-TYPE    
  TimeTicks  

llcCcOperRejTimer 1.3.6.1.4.1.9.10.8.1.3.2.1.9
This object denotes the value for the time interval during which this LLC shall expect to receive a reply to a REJ PDU. The expiration of this timer shall cause the REJ PDU to be retransmitted (up to N2 times).
Status: current Access: read-only
OBJECT-TYPE    
  TimeTicks  

llcCcOperBusyTimer 1.3.6.1.4.1.9.10.8.1.3.2.1.10
This object denotes the value for the time interval during which this LLC shall expect to receive an indication that a busy condition at the remote LLC has cleared. The expiration of this timer shall cause the link to be declared inactive.
Status: current Access: read-only
OBJECT-TYPE    
  TimeTicks  

llcCcOperInactTimer 1.3.6.1.4.1.9.10.8.1.3.2.1.11
This object denotes the value for the time interval during which this LLC shall expect to receive any PDU from the remote LLC. This function is not described in the IEEE 802.2 specification [5] but is widely implemented. The expiration of this timer shall cause the local LLC to send a PDU to the remote LLC with the P bit set to '1'. Any value for this object less than or equal to the acknowledgement timer shall mean that the timer is not used.
Status: current Access: read-only
OBJECT-TYPE    
  TimeTicks  

llcCcOperDelayAckCount 1.3.6.1.4.1.9.10.8.1.3.2.1.12
This object denotes the value for the maximum number of consecutive I PDUs which this LLC shall receive during the interval defined by llcCcOperDelayTimer without sending an immediate acknowledgement. This must be less than or equal to the value of llcCcOperMaxUnackIPDURcv. This function is not described in the IEEE 802.2 specification [5] but is widely implemented. A value of one indicates that acknowledgments will be sent immediately and that the value of llcCcOperDelayAckTimer should be ignored.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

llcCcOperDelayAckTimer 1.3.6.1.4.1.9.10.8.1.3.2.1.13
This object denotes the value for the time interval during which this LLC shall delay acknowledgment of one or more I PDUs (up to the value of llcCcOperDelayAckCount). This function is not described in the IEEE 802.2 specification [5] but is widely implemented. The expiration of this timer shall cause the local LLC to acknowledge all unacknowledged I PDUs. This object is associated with the llcCcOperDelayAckCount object and only has meaning if that object has a value greater than one.
Status: current Access: read-only
OBJECT-TYPE    
  TimeTicks  

llcCcOperNw 1.3.6.1.4.1.9.10.8.1.3.2.1.14
This object denotes the value for the number of IPDUs that must be acknowledged before the working window size (Ww) can be incremented by 1 when the working window is not equal to the maximum transmit window size (TW). It controls the gradual incrementing of Ww in congestion situations. This function is not described in the IEEE 802.2 specification [5], but is widely implemented.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

llcCcOperWw 1.3.6.1.4.1.9.10.8.1.3.2.1.15
Maximum number of sequentially numbered IPDUs that the connection component may have outstanding (unacknowledged) at any given time. Ww is initialized to the value of llcCcOperMaxUnackedIPDUsSend when the link is established. When the dynamic window algorithm is invoked, Ww varies from 1 up to llcCcOperMaxUnackedIPDUsSend. Each time the llcCcOperWw value is decreased, the reason is recorded in llcCcOperLastWwCause, and llcCcStatWwCount is incremented by 1. This function is not described in the IEEE 802.2 specification [5], but is widely implemented.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 1..127  

llcCcOperCreateTime 1.3.6.1.4.1.9.10.8.1.3.2.1.16
This object describes the value of sysUpTime when this connection was created.
Status: current Access: read-only
OBJECT-TYPE    
  TimeStamp  

llcCcOperLastModifyTime 1.3.6.1.4.1.9.10.8.1.3.2.1.17
This object describes the value of sysUpTime the last time this connection component was modified. If the connection has not been modified, then this value shall be zero.
Status: current Access: read-only
OBJECT-TYPE    
  TimeStamp  

llcCcOperLastFailTime 1.3.6.1.4.1.9.10.8.1.3.2.1.18
This object describes the value of sysUpTime when this LLC connection component last failed. If the connection component has not failed, then this value shall be zero.
Status: current Access: read-only
OBJECT-TYPE    
  TimeStamp  

llcCcOperLastFailCause 1.3.6.1.4.1.9.10.8.1.3.2.1.19
This enumerated object reflects the cause of the last failure of this LLC connection component. If the connection component has not failed, then this object will have a value of undefined(1).
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER undefined(1), rxFRMR(2), txFRMR(3), discReceived(4), discSent(5), retriesExpired(6), forcedShutdown(7)  

llcCcOperLastFailFRMRInfo 1.3.6.1.4.1.9.10.8.1.3.2.1.20
This object reflects the information field of the FRMR frame if the last failure for this LLC connection component was as a result of an invalid frame. Otherwise, this field has no meaning.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(3)  

llcCcOperLastWwCause 1.3.6.1.4.1.9.10.8.1.3.2.1.21
This object indicates the reason that the llcCcOperWw was reduced the last time this occurred.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER neverInvoked(1), lostData(2), macLayerCongestion(3), other(4)  

llcCcStatsTable 1.3.6.1.4.1.9.10.8.1.3.3
Each entry in this table contains statistics for a specific LLC connection component.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    LlcCcStatsEntry

llcCcStatsEntry 1.3.6.1.4.1.9.10.8.1.3.3.1
A list of statistics for an LLC connection component.
Status: current Access: not-accessible
OBJECT-TYPE    
  LlcCcStatsEntry  

llcCcStatsLocalBusies 1.3.6.1.4.1.9.10.8.1.3.3.1.1
This object reflects the total number of times that the local connection component has entered a busy state (RNR). This object is initialized to zero when the connection component is created.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

llcCcStatsRemoteBusies 1.3.6.1.4.1.9.10.8.1.3.3.1.2
This object reflects the total number of times that the adjacent (i.e. remote) connection component has entered a busy state (RNR). This object is initialized to zero when the connection component is created.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

llcCcStatsIFramesIn 1.3.6.1.4.1.9.10.8.1.3.3.1.3
This object reflects the total number of I-Frames that have been received by the connection component. This object is initialized to zero when the connection component is created.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

llcCcStatsIFramesOut 1.3.6.1.4.1.9.10.8.1.3.3.1.4
This object reflects the total number of I-Frames that have been transmitted by this connection component. This object is initialized to zero when the connection component is created.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

llcCcStatsIOctetsIn 1.3.6.1.4.1.9.10.8.1.3.3.1.5
This object reflects the total octets received from the adjacent connection component. This object covers the address, control, and information field of I-Frames only. This object is initialized to zero when the connection component is created.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

llcCcStatsIOctetsOut 1.3.6.1.4.1.9.10.8.1.3.3.1.6
This object reflects the total octets transmitted to the adjacent connection component. This object covers the address, control, and information field of I-Frames only. This object is initialized to zero when the connection component is created.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

llcCcStatsSFramesIn 1.3.6.1.4.1.9.10.8.1.3.3.1.7
This object reflects the total number of S-Frames that have been received by this connection component. This object is initialized to zero when the connection component is created. Note - the ratio of the number of I-Frames to S-Frames might serve as a measure of link efficiency and, for instance, could be used to tune the acknowledgement timer.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

llcCcStatsSFramesOut 1.3.6.1.4.1.9.10.8.1.3.3.1.8
This object reflects the total number of S-Frames that have been transmitted by this connection component. This object is initialized to zero when the connection component is created. Note - the ratio of the number of I-Frames to S-Frames might serve as a measure of link efficiency and, for instance, could be used to tune the acknowledgement timer.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

llcCcStatsRetransmitsOut 1.3.6.1.4.1.9.10.8.1.3.3.1.9
This object reflects the total number of I-Frames retransmitted the local connection component. This object is initialized to zero when the connection component is created.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

llcCcStatsREJsIn 1.3.6.1.4.1.9.10.8.1.3.3.1.10
This object reflects the total REJ frames received from an adjacent LLC connection component since connection component startup.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

llcCcStatsREJsOut 1.3.6.1.4.1.9.10.8.1.3.3.1.11
This object reflects the total REJ frames transmitted to an adjacent LLC connection component since connection component startup.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

llcCcStatsWwCount 1.3.6.1.4.1.9.10.8.1.3.3.1.12
This object reflects the total number of times, since connection component startup, that the dynamic window algorithm has been invoked to reduce the value of Ww. At connection component startupm this object must be initialized to zero. This function is not described in the IEEE 802.2 specification [5], but is widely implemented.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

snaLlcMIBNotificationPrefix 1.3.6.1.4.1.9.10.8.2
OBJECT IDENTIFIER    

snaLlcMIBNotifications 1.3.6.1.4.1.9.10.8.2.0
OBJECT IDENTIFIER    

llcCcStatusChange 1.3.6.1.4.1.9.10.8.2.0.1
This trap indicates that the state of an LLC connection component has transitioned to normal(3) or aDM(1).
Status: current Access: read-only
NOTIFICATION-TYPE    

snaLlcMIBConformance 1.3.6.1.4.1.9.10.8.3
OBJECT IDENTIFIER    

snaLlcMIBCompliances 1.3.6.1.4.1.9.10.8.3.1
OBJECT IDENTIFIER    

snaLlcMIBGroups 1.3.6.1.4.1.9.10.8.3.2
OBJECT IDENTIFIER    

llcCoreCompliance 1.3.6.1.4.1.9.10.8.3.1.1
The core compliance statement for all LLC nodes.
Status: current Access: read-only
MODULE-COMPLIANCE    

llcCorePortGroup 1.3.6.1.4.1.9.10.8.3.2.1
The llcCorePortGroup defines objects which are common to the LLC Port of all compliant connections.
Status: current Access: read-only
OBJECT-GROUP    

llcCoreSapGroup 1.3.6.1.4.1.9.10.8.3.2.2
The llcCoreSapGroup defines objects which are common to the LLC SAP of all compliant connections.
Status: current Access: read-only
OBJECT-GROUP    

llcCoreCcGroup 1.3.6.1.4.1.9.10.8.3.2.3
The llcCoreCcGroup defines objects which are common to the LLC CC of all compliant connections.
Status: current Access: read-only
OBJECT-GROUP