CpeExtPsePortEntry |
|
SEQUENCE |
|
|
|
|
cpeExtPsePortEnable |
INTEGER |
|
|
cpeExtPsePortDiscoverMode |
INTEGER |
|
|
cpeExtPsePortDeviceDetected |
TruthValue |
|
|
cpeExtPsePortIeeePd |
TruthValue |
|
|
cpeExtPsePortAdditionalStatus |
BITS |
|
|
cpeExtPsePortPwrMax |
Unsigned32 |
|
|
cpeExtPsePortPwrAllocated |
Unsigned32 |
|
|
cpeExtPsePortPwrAvailable |
Unsigned32 |
|
|
cpeExtPsePortPwrConsumption |
Unsigned32 |
|
|
cpeExtPsePortMaxPwrDrawn |
Unsigned32 |
|
|
cpeExtPsePortEntPhyIndex |
EntPhysicalIndexOrZero |
|
|
cpeExtPsePortPolicingCapable |
TruthValue |
|
|
cpeExtPsePortPolicingEnable |
INTEGER |
|
|
cpeExtPsePortPolicingAction |
INTEGER |
|
|
cpeExtPsePortPwrManAlloc |
Unsigned32 |
|
|
cpeExtPsePortCapabilities |
BITS |
|
CpeExtMainPseEntry |
|
SEQUENCE |
|
|
|
|
cpeExtMainPseEntPhyIndex |
EntPhysicalIndexOrZero |
|
|
cpeExtMainPseDescr |
SnmpAdminString |
|
|
cpeExtMainPsePwrMonitorCapable |
TruthValue |
|
CpeExtPsePortLldpEntry |
|
SEQUENCE |
|
|
|
|
cpeExtPsePortLldpPwrType |
CpeExtLldpPwrType |
|
|
cpeExtPsePortLldpPdPwrType |
CpeExtLldpPwrType |
|
|
cpeExtPsePortLldpPwrSrc |
CpeExtLldpPwrSrc |
|
|
cpeExtPsePortLldpPdPwrSrc |
CpeExtLldpPwrSrc |
|
|
cpeExtPsePortLldpPwrPriority |
CpeExtPwrPriority |
|
|
cpeExtPsePortLldpPdPwrPriority |
CpeExtPwrPriority |
|
|
cpeExtPsePortLldpPwrReq |
Unsigned32 |
|
|
cpeExtPsePortLldpPdPwrReq |
Unsigned32 |
|
|
cpeExtPsePortLldpPwrAlloc |
Unsigned32 |
|
|
cpeExtPsePortLldpPdPwrAlloc |
Unsigned32 |
|
|
cpeExtPsePortLldpPwrClass |
CpeExtLldpPwrClassOrZero |
|
|
cpeExtPsePortLldpPdPwrClass |
CpeExtLldpPwrClassOrZero |
|
|
cpeExtPsePortLldpPdPwrSupport |
BITS |
|
|
cpeExtPsePortLldpPdPwrPairsOrZero |
INTEGER |
|
ciscoPowerEthernetExtMIB |
4.9.402 |
A MIB module for extending the POWER-ETHERNET-MIB
(RFC3621) to add objects which provide additional
management information about Power Sourcing Equipment
(PSE) not available in POWER-ETHERNET-MIB.
Glossary
Power Sourcing Equipment (PSE)
These are devices supplying electrical power to
other equipment. They are, for example, inline power
switches, inline power daughterboards and power patch
panels.
Powered Device (PD)
These are devices receiving their electrical power
supply from Power Sourcing Equipment. They are, for
example, IP telephones and wireless access points
or bridges. |
MODULE-IDENTITY |
|
|
|
cpeExtPsePortEntry |
4.9.402.1.2.1 |
A cpeExtPsePortEntry extends a corresponding
pethPsePortTable entry. This entry displays and
controls more characteristics of a power Ethernet
port on a PSE device. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
CpeExtPsePortEntry |
|
|
cpeExtPsePortEnable |
4.9.402.1.2.1.1 |
This object is an extension of the pethPsePortAdminEnable
object from RFC3621. It allows the user to be more specific
when enabling the PSE functions. The states, 'auto', 'static'
and 'limit' correspond to a value of 'true' for the
pethPsePortAdminEnable object. The state 'disable' corresponds
to a value of 'false' for the pethPsePortAdminEnable object.
Setting this value to 'auto' enables Powered Device discovery
on the interface and the amount of power allocated depends on
the Powered Device discovered. If pethPsePortAdminEnable was
'false' prior to this set operation, then it will become
'true'.
Setting this value to 'static' will also enable Powered
Device discovery. However, this is different from 'auto'
in that the amount of power is pre-allocated based on the
configuration on the Power Sourcing Equipment. If
pethPsePortAdminEnable was 'false' prior to this set
operation, then it will become 'true'.
Setting this value to 'limit' enables Powered Device
discovery on the interface. The amount of power allocated
depends on the Powered Device discovered and the value
of cpeExtPsePortPwrMax. The lower value will be used.
If pethPsePortAdminEnable was 'false' prior to this set
operation, then it will become 'true'.
Setting this value to 'disable' disables the PSE functions.
The pethPsePortAdminEnable object will adopt the value of
'false' if it was 'true' prior to this set operation. When
setting the pethPsePortAdminEnable object to 'false' this
object cpeExtPsePortEnable will adopt the value of 'disable'.
If cpeExtPsePortPolicingCapable of the PSE port, or
cpeExtMainPsePwrMonitorCapable of the PSE port's
main group, has the value of 'false', this object
can only be set to 'auto', 'static' or 'disable'.
Otherwise, this object can be set to 'auto', 'static',
'limit' or 'disable'. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
auto(1), static(2), limit(3), disable(4) |
|
cpeExtMainPseTable |
4.9.402.1.3 |
This table contains the additional information for the
main PSE group in pethMainPseTable. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
SEQUENCE OF |
|
|
|
|
CpeExtMainPseEntry |
|
cpeExtMainPseEntry |
4.9.402.1.3.1 |
A cpeExtMainPseEntry contains information about
a particular pethMainPseGroupIndex. An entry is
created by the agent when a main PSE group is added
to the pethMainPseTable. An entry is deleted by the
agent when a main PSE group is removed from the
pethMainPseTable. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
CpeExtMainPseEntry |
|
|
cpeExtMainPseEntPhyIndex |
4.9.402.1.3.1.1 |
The entPhysicalIndex value that uniquely identifies the
main PSE group. If the main PSE group does not have a
corresponding physical entry in entPhysicalTable or if
the entPhysicalTable is not supported by the management
system, then this object has the value of zero. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
EntPhysicalIndexOrZero |
|
|
cpeExtMainPseDescr |
4.9.402.1.3.1.2 |
A textual string containing information about the Power
Source Equipment (PSE) group. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
SnmpAdminString |
|
|
cpeExtMainPsePwrMonitorCapable |
4.9.402.1.3.1.3 |
This object indicates if the given group is capable of
monitoring the power consumption of the interfaces that
belong to the group. The value 'true' means that the
group is capable. The value 'false' means that the group
in not capable. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
TruthValue |
|
|
cpeExtPdStatsEntry |
4.9.402.1.4.2.1 |
A cpeExtPdStatsEntry contains the statistics
information about a particular power classification
defined in cpeExtPdStatsIndex. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
CpeExtPdStatsEntry |
|
|
cpeExtPsePortLldpEntry |
4.9.402.1.7.1 |
A cpeExtPsePortLldpEntry entry contains the LLDP
based 802.3at DLL power classification characteristics for
a particular PSE and the PD attached to it.
A PSE has its entry here when all of the following conditions
are satisfied:
- The LLDP power classification is globally enabled.
- It has a PD attached.
- LLDP is the operational power negotiation protocol between
the PSE and the PD attached. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
CpeExtPsePortLldpEntry |
|
|
cpeExtMainPseGroup |
4.9.402.2.2.4 |
This is a collection of objects which provide
additional information for the PSE group.
cpeExtMainPseGroup object is superseded by cpeExtMainPseGroup2,
and cpeExtPseGrpPwrGroup. |
Status: deprecated |
Access: read-only |
OBJECT-GROUP |
|
|
|
cpeExtMainPseGroup2 |
4.9.402.2.2.8 |
This is a collection of objects which provide
additional information to identify the PSE group. |
Status: current |
Access: read-only |
OBJECT-GROUP |
|
|
|