CISCO-MODULE-AUTO-SHUTDOWN-MIB

File: CISCO-MODULE-AUTO-SHUTDOWN-MIB.mib (12798 bytes)

Imported modules

SNMPv2-SMI SNMPv2-CONF SNMPv2-TC
SNMP-FRAMEWORK-MIB ENTITY-MIB CISCO-SMI

Imported symbols

MODULE-IDENTITY OBJECT-TYPE NOTIFICATION-TYPE
Gauge32 Unsigned32 MODULE-COMPLIANCE
OBJECT-GROUP NOTIFICATION-GROUP TruthValue
DateAndTime TEXTUAL-CONVENTION SnmpAdminString
entPhysicalIndex entPhysicalName entPhysicalModelName
ciscoMgmt

Defined Types

CiscoModuleAutoShutSysAction  
The type of system initiated action. Valid values are: other(1): none of the below. reset(2): reset the module. powerCycle(3): power cycle the module. powerDown(4): power down the module.
TEXTUAL-CONVENTION    
  INTEGER other(1), reset(2), powerCycle(3), powerDown(4)  

CmasModuleEntry  
SEQUENCE    
  cmasModuleEnable TruthValue
  cmasModuleNumResets Gauge32
  cmasModuleLastResetReason SnmpAdminString
  cmasModuleLastResetTime DateAndTime

Defined Values

ciscoModuleAutoShutdownMIB 1.3.6.1.4.1.9.9.386
The CISCO-MODULE-AUTO-SHUTDOWN-MIB is used to configure the module automatic shutdown feature. Modules will be reset by the system when they become faulty. The module auto shutdown feature will shutdown such faulty modules when the resets occur too often. Once the modules are shutdown by this feature, they will stay shutdown until the administrator manually brings them back up. This will prevent the system from constantly resetting the faulty modules. This MIB module also covers the system initiated action occuring on a module.
MODULE-IDENTITY    

cmasMIBNotifs 1.3.6.1.4.1.9.9.386.0
OBJECT IDENTIFIER    

cmasMIBObjects 1.3.6.1.4.1.9.9.386.1
OBJECT IDENTIFIER    

cmasMIBConformance 1.3.6.1.4.1.9.9.386.2
OBJECT IDENTIFIER    

cmasGlobal 1.3.6.1.4.1.9.9.386.1.1
OBJECT IDENTIFIER    

cmasNotifObjects 1.3.6.1.4.1.9.9.386.1.2
OBJECT IDENTIFIER    

cmasModule 1.3.6.1.4.1.9.9.386.1.3
OBJECT IDENTIFIER    

cmasModuleSysActionObjects 1.3.6.1.4.1.9.9.386.1.4
OBJECT IDENTIFIER    

cmasFrequency 1.3.6.1.4.1.9.9.386.1.1.1
This indicates the threshold of the number of times the system can reset a faulty module, within the period specified by 'cmasPeriod'. Once the number of these system initiated resets exceeds this threshold, the module auto shutdown feature will shut down the module.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32  

cmasPeriod 1.3.6.1.4.1.9.9.386.1.1.2
This indicates the period of time over which the number of system initiated module resets is monitored. In order for the module to be automatically shutdown, the number of times the system must reset the module has to exceed cmasFreqency times, in a span of cmasPeriod.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32  

cmasMIBEnableNotification 1.3.6.1.4.1.9.9.386.1.2.1
This object indicates whether the system produces the cmasModuleAutoShutdown notification.
Status: current Access: read-write
OBJECT-TYPE    
  TruthValue  

cmasModuleSysActionNotifEnable 1.3.6.1.4.1.9.9.386.1.2.2
This object indicates whether the system produces the cmasModuleSysActionNotif notification.
Status: current Access: read-write
OBJECT-TYPE    
  TruthValue  

cmasModuleTable 1.3.6.1.4.1.9.9.386.1.3.1
This table contains information regarding the module auto shutdown feature.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    CmasModuleEntry

cmasModuleEntry 1.3.6.1.4.1.9.9.386.1.3.1.1
This entry contains information about the module auto shutdown feature. Each entry represents whether the feature is enabled, the number of resets, the last reset reason and the last reset time. Each entry is applicable for the modules capable of this feature and are identified by 'entPhysicalIndex' with entPhysicalClass value 'module'.
Status: current Access: not-accessible
OBJECT-TYPE    
  CmasModuleEntry  

cmasModuleEnable 1.3.6.1.4.1.9.9.386.1.3.1.1.1
This object enables or disables the auto shutdown feature on a module. When the object is true(1), auto shutdown is enabled for that module. The feature will start monitoring system initiated module resets, and initiate a shutdown operation on the module if the number of resets, cmasModuleNumResets, exceeds the cmasFrequency within the previous cmasPeriod of time. When the object is false(2), auto shutdown is disabled for that module.
Status: current Access: read-write
OBJECT-TYPE    
  TruthValue  

cmasModuleNumResets 1.3.6.1.4.1.9.9.386.1.3.1.1.2
This indicates the number of system initiated module resets that have occurred. This does not include user initiated module resets.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

cmasModuleLastResetReason 1.3.6.1.4.1.9.9.386.1.3.1.1.3
This object identifies the reason for the last module reset initiated by the system. This object will contain a zero-length string if no such resets have occurred.
Status: current Access: read-only
OBJECT-TYPE    
  SnmpAdminString  

cmasModuleLastResetTime 1.3.6.1.4.1.9.9.386.1.3.1.1.4
This object corresponds to the date and time when the last system initiated module reset occurred. This object will contain 0-1-1,00:00:00:0 if no system initiated resets have occurred.
Status: current Access: read-only
OBJECT-TYPE    
  DateAndTime  

cmasModuleSysAction 1.3.6.1.4.1.9.9.386.1.4.1
This object identifies the system initiated action which is applied to a module.
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  CiscoModuleAutoShutSysAction  

cmasModuleSysActionReason 1.3.6.1.4.1.9.9.386.1.4.2
This object identifies the reason of system initiated action which is applied to a module.
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  SnmpAdminString  

cmasModuleAutoShutdown 1.3.6.1.4.1.9.9.386.0.1
This notification is generated when the module auto shutdown feature shuts down a module.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

cmasModuleSysActionNotif 1.3.6.1.4.1.9.9.386.0.2
This notification is generated when a system initiated action occurs on a module.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

cmasMIBCompliances 1.3.6.1.4.1.9.9.386.2.1
OBJECT IDENTIFIER    

cmasMIBGroups 1.3.6.1.4.1.9.9.386.2.2
OBJECT IDENTIFIER    

cmasMIBCompliance 1.3.6.1.4.1.9.9.386.2.1.1
The compliance statement for the CISCO-MODULE-AUTO-SHUTDOWN-MIB
Status: deprecated Access: accessible-for-notify
MODULE-COMPLIANCE    

cmasMIBCompliance2 1.3.6.1.4.1.9.9.386.2.1.2
The compliance statement for the CISCO-MODULE-AUTO-SHUTDOWN-MIB
Status: current Access: accessible-for-notify
MODULE-COMPLIANCE    

cmasModuleGroup 1.3.6.1.4.1.9.9.386.2.2.1
A collection of objects which are used to configure as well as show information regarding the module auto shutdown feature.
Status: current Access: accessible-for-notify
OBJECT-GROUP    

cmasNotificationEnableGroup 1.3.6.1.4.1.9.9.386.2.2.2
A collection of objects which are used to enable notifications.
Status: current Access: accessible-for-notify
OBJECT-GROUP    

cmasNotificationsGroup 1.3.6.1.4.1.9.9.386.2.2.3
A collection of notifications for the module auto shutdown feature.
Status: current Access: accessible-for-notify
NOTIFICATION-GROUP    

cmasModuleSysActionGroup 1.3.6.1.4.1.9.9.386.2.2.4
A collection of objects which are related with the notification cmasModuleSysActionNotif. They are either used to enable and disable this notification or included in this notification PDU.
Status: current Access: accessible-for-notify
OBJECT-GROUP    

cmasNotificationsGroup2 1.3.6.1.4.1.9.9.386.2.2.5
A collection of notifications for the system initiated module action feature.
Status: current Access: accessible-for-notify
NOTIFICATION-GROUP