CISCO-FASTHUB-MIB

File: CISCO-FASTHUB-MIB.mib (54701 bytes)

Imported modules

RFC1155-SMI RFC-1215 RFC-1212
CISCO-SMI RFC1213-MIB

Imported symbols

Counter TimeTicks IpAddress
TRAP-TYPE OBJECT-TYPE local
sysName DisplayString

Defined Types

VisualLEDMap  
OCTET STRING    

MrSupervisorLogEntry  
SEQUENCE    
  mrSupervisorLogIndex INTEGER
  mrSupervisorLogTime DisplayString
  mrSupervisorLogInfo DisplayString
  mrSupervisorLogRelativeTime TimeTicks

MrStackUnitEntry  
SEQUENCE    
  mrStackUnitIndex INTEGER
  mrStackUnitPresent INTEGER
  mrStackUnitFirstGroupIndex INTEGER
  mrStackUnitLastGroupIndex INTEGER
  mrStackUnitSupervisorPresent INTEGER
  mrStackUnitSupervisorMajorVersion INTEGER
  mrStackUnitSupervisorMinorVersion INTEGER
  mrStackUnitSupervisorBootstrapMajorVersion INTEGER
  mrStackUnitSupervisorBootstrapMinorVersion INTEGER
  mrStackUnitPOSTResult OCTET STRING
  mrStackUnitSupervisorIsPrimary INTEGER
  mrStackUnitExpansionModulePresent INTEGER
  mrStackUnitPortVisualIndicatorSelect INTEGER
  mrStackUnitBasePortVisualIndicatorGreenMap VisualLEDMap
  mrStackUnitBasePortVisualIndicatorAmberMap VisualLEDMap
  mrStackUnitExpansionPortVisualIndicatorGreenMap VisualLEDMap
  mrStackUnitExpansionPortVisualIndicatorAmberMap VisualLEDMap
  mrStackUnitActivityVisualIndicator INTEGER
  mrStackUnitCollisionVisualIndicator INTEGER
  mrStackUnitRPSStatus INTEGER
  mrStackUnitRPSVisualIndicator INTEGER
  mrStackUnitSerialNumber DisplayString

MrNetMgmtSetClientEntry  
SEQUENCE    
  mrNetMgmtSetClientIndex INTEGER
  mrNetMgmtSetClientName DisplayString
  mrNetMgmtSetClientStatus INTEGER

MrNetMgmtTrapClientEntry  
SEQUENCE    
  mrNetMgmtTrapClientIndex INTEGER
  mrNetMgmtTrapClientName DisplayString
  mrNetMgmtTrapClientComm DisplayString
  mrNetMgmtTrapClientStatus INTEGER

Defined Values

ciscoFastHubMIB 1.3.6.1.4.1.9.2.11
OBJECT IDENTIFIER    

ciscoFastHubMIBObjects 1.3.6.1.4.1.9.2.11.1
OBJECT IDENTIFIER    

mrStack 1.3.6.1.4.1.9.2.11.1.1
OBJECT IDENTIFIER    

mrSupervisorLog 1.3.6.1.4.1.9.2.11.1.2
OBJECT IDENTIFIER    

mrStackUnit 1.3.6.1.4.1.9.2.11.1.3
OBJECT IDENTIFIER    

mrNetMgmt 1.3.6.1.4.1.9.2.11.1.4
OBJECT IDENTIFIER    

mrUpgrade 1.3.6.1.4.1.9.2.11.1.5
OBJECT IDENTIFIER    

mrStackUnitCapacity 1.3.6.1.4.1.9.2.11.1.1.1
This object returns the maximum number of repeater units that can be stacked in the system and managed as one repeater.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

mrStackNumberOfUnitsPresent 1.3.6.1.4.1.9.2.11.1.1.2
This object returns the current number of repeater units in the stack.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

mrStackSelectPrimarySupervisorUnit 1.3.6.1.4.1.9.2.11.1.1.3
In a multi-unit FastHub stack with more than one Supervisor management module installed, this object selects which unit and hence, which Supervisor module, should have the primary management role. The value specified is a unit number that corresponds to an integer index into the mrStackUnitTable. Once a primary management unit has been chosen, the remaining management modules, if any, will automatically assume the standby role.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

mrStackPOSTSelect 1.3.6.1.4.1.9.2.11.1.1.4
normal(1), -- standard length test abbreviated(2) -- shortened test This object configures the type of Supervisor Power On Self Test FastHub will run upon power up. The normal(1) setting runs the lengthy and complete version of the self test. The abbreviated(2) setting shortens some of the RAM tests to reduce the start up time.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER normal(1), abbreviated(2)  

mrStackReset 1.3.6.1.4.1.9.2.11.1.1.5
reset(1) -- reset noReset(2), -- do nothing A write to this object with reset(1) causes a complete reset of the repeater hardware and the Supervisor but does not run the POST. All FastHub configuration parameters are retained and all network related statistics in the system are cleared. Setting this object to noReset(2) has no effect. FastHub will always return noReset(2) when this object is read.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER reset(1), noReset(2)  

mrStackDefaultReset 1.3.6.1.4.1.9.2.11.1.1.6
reset(1) -- reset noReset(2), -- do nothing A write to this object with reset(1) causes a complete reset of the repeater hardware and the Supervisor but does not run the POST. All FastHub configuration parameters revert to their default factory settings, and all network related statistics in the system are cleared. Setting this object to noReset(2) has no effect. FastHub will always return noReset(2) when this object is read.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER reset(1), noReset(2)  

mrStackClearStatistics 1.3.6.1.4.1.9.2.11.1.1.7
clear(1) -- clear interface statistics noClear(2), -- do nothing A write to this object with noClear(2) results in no action. A write of clear(1) will cause FastHub to reset all repeater statistics to zero. FastHub will also update the object rptrGroupLastOperStatusChange for all applicable repeater groups. This object always returns noClear(2) when read.
Status: obsolete Access: read-write
OBJECT-TYPE    
  INTEGER clear(1), noClear(2)  

mrStackShortJabberLoopCorrections 1.3.6.1.4.1.9.2.11.1.1.8
This object contains a count of the number of times a short event loop or jabber loop condition--caused by loopback cables--was detected and corrected.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

mrSupervisorLogTableClear 1.3.6.1.4.1.9.2.11.1.2.1
clear(1) -- clear current mrSupervisorLogTable noClear(2), -- do nothing A write to this object with noClear(2) results in no action. A write of clear(1) will clear all current entries in the mrSupervisorLogTable. A new entry will then be added to log this clear action. This object always return noClear(2) when read.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER clear(1), noClear(2)  

mrSupervisorLogTable 1.3.6.1.4.1.9.2.11.1.2.2
The mrSupervisorLogTable provides read access to the Supervisor log. Each table entry, identified by a unique index, holds one DisplayString object containing the logged information. The entire table can be retrieved one entry at a time using the get-next operation. The table can be cleared using the object sysConfigClearLogTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MrSupervisorLogEntry

mrSupervisorLogEntry 1.3.6.1.4.1.9.2.11.1.2.2.1
Supervisor Log entry.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  MrSupervisorLogEntry  

mrSupervisorLogIndex 1.3.6.1.4.1.9.2.11.1.2.2.1.1
A value identifying a unique entry in the mrSupervisorLogTable.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

mrSupervisorLogTime 1.3.6.1.4.1.9.2.11.1.2.2.1.2
Text string containing the date and time this log entry was created.
Status: obsolete Access: read-only
OBJECT-TYPE    
  DisplayString  

mrSupervisorLogInfo 1.3.6.1.4.1.9.2.11.1.2.2.1.3
A free formatted display string containing some descriptive text about a certain system state change.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

mrSupervisorLogRelativeTime 1.3.6.1.4.1.9.2.11.1.2.2.1.4
The value of sysUpTime when this log entry was created. A value of 0 indicates that the entry was logged before the last reset.
Status: mandatory Access: read-only
OBJECT-TYPE    
  TimeTicks  

mrStackUnitTable 1.3.6.1.4.1.9.2.11.1.3.1
The mrStackUnitTable provides configuration information about hot-insertable enclosures. Each table entry, identified by a unique index, describes one such enclosure (called unit).
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MrStackUnitEntry

mrStackUnitEntry 1.3.6.1.4.1.9.2.11.1.3.1.1
Stack unit table entry.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  MrStackUnitEntry  

mrStackUnitIndex 1.3.6.1.4.1.9.2.11.1.3.1.1.1
A number identifying a unique FastHub unit. This number corresponds to the physical box unit number in the stack.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

mrStackUnitPresent 1.3.6.1.4.1.9.2.11.1.3.1.1.2
This object contains true(1) if the unit identified by mrStackUnitIndex is present in the stack. The object contains false(2) otherwise. Default value: false(2).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER true(1), false(2)  

mrStackUnitFirstGroupIndex 1.3.6.1.4.1.9.2.11.1.3.1.1.3
This object contains a value which corresponds to an RFC-1516 group index. It identifies the first of the one or more repeater groups present in this unit. All groups belonging to a same FastHub unit are indexed using consecutive integer values.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

mrStackUnitLastGroupIndex 1.3.6.1.4.1.9.2.11.1.3.1.1.4
This object contains a value which corresponds to an RFC-1516 group index. It identifies the last of the one or more repeater groups present in this unit. All groups belonging to a same FastHub unit are indexed using consecutive integer values.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

mrStackUnitSupervisorPresent 1.3.6.1.4.1.9.2.11.1.3.1.1.5
This object contains true(1) if a Supervisor module is installed in the unit. The object contains false(2) otherwise. Default value: false(2).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER true(1), false(2)  

mrStackUnitSupervisorMajorVersion 1.3.6.1.4.1.9.2.11.1.3.1.1.6
If a Supervisor module is installed in the unit, this object returns its major firmware version number. This object contains 0 if the unit does not have a Supervisor module installed. Default value: 0.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

mrStackUnitSupervisorMinorVersion 1.3.6.1.4.1.9.2.11.1.3.1.1.7
If a Supervisor module is installed in the unit, this object returns its minor firmware version number. This object contains 0 if the unit does not have a Supervisor module installed. Default value: 0.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

mrStackUnitSupervisorBootstrapMajorVersion 1.3.6.1.4.1.9.2.11.1.3.1.1.8
If a Supervisor module is installed in the unit, this object returns its major bootstrap version number. This object contains 0 if the unit does not have a Supervisor module installed. Default value: 0.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

mrStackUnitSupervisorBootstrapMinorVersion 1.3.6.1.4.1.9.2.11.1.3.1.1.9
If a Supervisor module is installed in the unit, this object returns its minor bootstrap version number. This object contains 0 if the unit does not have a Supervisor module installed. Default value: 0.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

mrStackUnitPOSTResult 1.3.6.1.4.1.9.2.11.1.3.1.1.10
A bit array where the presence of a particular bit indicates a failure of a particular Power On Self Test (POST). Each octet within the value of this object specifies a set of 8 POST tests, with the first octet specifying tests 1 through 8, the second octet specifying tests 9 through 16, etc. Within each octet, the most significant bit represents the lowest numbered test, and the least significant bit represents the highest numbered test. Thus, each test is represented by a single bit within the value of this object. If that bit has a value of '1' then that test has failed; the test has passed if its bit has a value of '0'. The defined POST tests are: Number POST Test ------ --------- 1 Supervisor RAM 2 EIA/TIA-232 console port 3 Ethernet address 4 Timer interrupt 5 Real time clock 6 Non-volatile RAM 7 Port loopback Default value: string of length 0.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

mrStackUnitSupervisorIsPrimary 1.3.6.1.4.1.9.2.11.1.3.1.1.11
true(1), -- unit contains the primary management module false(2) -- unit has no management module or contains -- a standby management module If the current unit has a management module installed (mrStackUnitSupervisorPresent is true), this object indicates whether the module is acting as the primary management Supervisor. If there is no management module present, this object will return the value false(2). Default value: false(2).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER true(1), false(2)  

mrStackUnitExpansionModulePresent 1.3.6.1.4.1.9.2.11.1.3.1.1.12
This object contains true(1) if an expansion module is installed in the unit. The object contains false(2) otherwise. Default value: false(2).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER true(1), false(2)  

mrStackUnitPortVisualIndicatorSelect 1.3.6.1.4.1.9.2.11.1.3.1.1.13
portStatus(1), -- LED shows port link/activity unitNumber(2), -- LED shows unit number utilization(3) -- LED shows utilization This object reflects what is currently selected as the port visual indication mode. The portStatus(1) mode uses the visual LEDs to indicate port link and activity status. The unitNumber(2) mode shows the position of the unit in the stack (the unit number). The utilization(3) mode uses the port visual LEDs to display the repeater backplane bandwidth utilization. Default value: portStatus(1).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER portStatus(1), unitNumber(2), utilization(3)  

mrStackUnitBasePortVisualIndicatorGreenMap 1.3.6.1.4.1.9.2.11.1.3.1.1.14
The current value of the green visual LED map, representing link or activity, for ports on the unit's main board. Default value: string of length 0.
Status: mandatory Access: read-only
OBJECT-TYPE    
  VisualLEDMap  

mrStackUnitBasePortVisualIndicatorAmberMap 1.3.6.1.4.1.9.2.11.1.3.1.1.15
The current value of the amber visual LED map, representing disabled status, for ports on the unit's main board. Default value: string of length 0.
Status: mandatory Access: read-only
OBJECT-TYPE    
  VisualLEDMap  

mrStackUnitExpansionPortVisualIndicatorGreenMap 1.3.6.1.4.1.9.2.11.1.3.1.1.16
The current value of the green visual LED map, representing link or activity, for ports on the unit's expansion module. Default value: string of length 0.
Status: mandatory Access: read-only
OBJECT-TYPE    
  VisualLEDMap  

mrStackUnitExpansionPortVisualIndicatorAmberMap 1.3.6.1.4.1.9.2.11.1.3.1.1.17
The current value of the amber visual LED map, representing disabled status, for ports on the unit's expansion module. Default value: string of length 0.
Status: mandatory Access: read-only
OBJECT-TYPE    
  VisualLEDMap  

mrStackUnitActivityVisualIndicator 1.3.6.1.4.1.9.2.11.1.3.1.1.18
This object has the value true(1) when the unit activity visual LED is lit. Otherwise, it has the value false(2). Initial value: false(2).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER true(1), false(2)  

mrStackUnitCollisionVisualIndicator 1.3.6.1.4.1.9.2.11.1.3.1.1.19
This object has the value true(1) when the unit collision visual LED is lit. Otherwise, it has the value false(2). Initial value: false(2).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER true(1), false(2)  

mrStackUnitRPSStatus 1.3.6.1.4.1.9.2.11.1.3.1.1.20
notPresent(1), -- no RPS present connectedFunctional(2), -- both internal and RPS supplying power conectedNotFunctional(3), -- RPS connected but is down functionalPrimaryFailed(4) -- RPS is supplying power This object shows the status of the remote redundant power supply connected to the unit. This MIB object returns notPresent(1) when there is no RPS connected to the unit. This object returns connectedFunctional(2) if there is a RPS and both internal and RPS are supplying power to the unit. It returns connectedNotFunctional(3) if the RPS is connected but down. It returns functionalPrimaryFailed(4) if the internal power supply failed and RPS is supplying power to the unit. Default value: notPresent(1).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER notPresent(1), connectedFunctional(2), connectedNotFunctional(3), functionalPrimaryFailed(4)  

mrStackUnitRPSVisualIndicator 1.3.6.1.4.1.9.2.11.1.3.1.1.21
This object has one of the following values: off(1), -- no RPS present green(2), -- RPS healthy amber(3) -- RPS not healthy Initial value: off(1).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER off(1), green(2), amber(3)  

mrStackUnitSerialNumber 1.3.6.1.4.1.9.2.11.1.3.1.1.22
This object has the serial number of the unit.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

mrNetMgmtIpAddress 1.3.6.1.4.1.9.2.11.1.4.1
The FastHub Supervisor IP address. FastHub may automatically discover a value for this object using BOOTP, or DHCP. The object value is also duplicated in the MIB-II ipAddrTable. A write to this object will take effect immediately, replacing the previous address, if any. Default value: 0.0.0.0, or no address.
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

mrNetMgmtIpSubnetMask 1.3.6.1.4.1.9.2.11.1.4.2
The FastHub Supervisor IP subnet mask. The firmware may automatically discover a value for this object using BOOTP, DHCP or RARP. The object value is also duplicated in the MIB-II ipAddrTable. A write to this object will take effect immediately, replacing the previous subnet mask, if any. Default value: 0.0.0.0, or no mask.
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

mrNetMgmtDefaultGateway 1.3.6.1.4.1.9.2.11.1.4.3
The IP address of a default gateway. A write to this object will take effect immediately, replacing the previous address, if any. Default value: 0.0.0.0, or no gateway address.
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

mrNetMgmtEnableAuthenTraps 1.3.6.1.4.1.9.2.11.1.4.4
enabled(1), -- trap generation is enabled disabled(2) -- trap generation is disabled Indicates whether the SNMP Agent is allowed to generate authenticationFailure traps. The value of this object overrides any configuration information; as such, it provides a means whereby all authenticationFailure traps may be disabled(2). This object manipulates the same value for the MIB-II snmpEnableAuthenTraps object instance. The value is duplicated here for convenience. Default value: enabled(1).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

mrNetMgmtEnableRIP 1.3.6.1.4.1.9.2.11.1.4.6
enabled(1), -- RIP listener is enabled disabled(2) -- RIP listener is disabled This object controls whether the FastHub Supervisor will run the Routing Information Protocol listener to automatically discover IP gateways. Default value: enabled(1).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

mrNetMgmtConsoleInactTime 1.3.6.1.4.1.9.2.11.1.4.7
The number of seconds (minimum of 30) of Management Console session inactivity to wait before ending the session. Once a session has ended, the user must resupply the Console password to regain access. A value of zero indicates no timeout. Default value: 0.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..65500  

mrNetMgmtConsolePasswordThreshold 1.3.6.1.4.1.9.2.11.1.4.8
The number of consecutive invalid password attempts allowed before the Management Console is shut down for a configured duration. A zero value permits unlimited attempts. Default value: 3.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..65500  

mrNetMgmtConsoleSilentTime 1.3.6.1.4.1.9.2.11.1.4.9
The number of minutes during which the Management Console will be unavailable after repeated failed attempts to log on. A zero value specifies no silent time. Default value: 0.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..65500  

mrNetMgmtModemInitString 1.3.6.1.4.1.9.2.11.1.4.10
A string of up to 48 characters used to configured a modem connected to the RS-232 port. Specify this string if the modem is not Hayes compatible. Only the initialization commands need to be specified (i.e., do not specify any modem prefix string such as the AT attention sequence, or any suffix such as the CR character). This string takes effect after every line hang-up. Default value: string of length 0.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..48)  

mrNetMgmtModemDialString 1.3.6.1.4.1.9.2.11.1.4.11
This string of up to 48 characters contains a phone number used to establish a modem connection with a remote site. Only the phone number needs be specified (i.e., do not specify any dial prefix string such as ATDT). Leave this string empty (the default value), if the dial-out capability is not desired. This string takes effect after every line hang-up. Default value: string of length 0.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..48)  

mrNetMgmtModemDialDelay 1.3.6.1.4.1.9.2.11.1.4.12
Specifies a delay in seconds between every dial-out failure. The value zero indicates an infinite delay (no retry after the first failure). Normally, FastHub will attempt a dial-out if the mrNetMgmtModemDialString object is non-empty. If the dial-out fails, and auto-answer has been disabled on this system, the firmware will retry the dial-out after this delay has passed. If auto-answer is enabled and the first dial-out attempt fails, the system will immediately go into auto-answer mode. Default value: 300.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..65500  

mrNetMgmtModemAutoAnswer 1.3.6.1.4.1.9.2.11.1.4.13
Specifies whether the system should be in auto-answer mode and only accepts incoming calls. Note that the system will always attempt a dial-out first if mrNetMgmtModemDialString is non-empty. Valid values are enabled(1) and disabled(2). Default value: enabled(1).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

mrNetMgmtDomainServer1IpAddress 1.3.6.1.4.1.9.2.11.1.4.14
The IP address of a Domain Name Server (DNS) which FastHub uses to resolve domain names to IP addresses. A set on this object takes effect the next time FastHub has to resolve a domain name. Default value: 0.0.0.0, or no address.
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

mrNetMgmtDomainServer2IpAddress 1.3.6.1.4.1.9.2.11.1.4.15
The IP address of a second Domain Name Server (DNS) which FastHub uses to resolve domain names to IP addresses. A set on this object takes effect the next time FastHub needs to resolve a domain name. Default value: 0.0.0.0, or no address.
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

mrNetMgmtDefaultSearchDomain 1.3.6.1.4.1.9.2.11.1.4.16
A string of up to 63 characters specifying a default domain search path. When FastHub needs to resolve a domain name that is not fully specified, it appends this default domain path to the name and continues the resolution attempt. Default value: string of length 0.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..63)  

mrNetMgmtSetClientTable 1.3.6.1.4.1.9.2.11.1.4.17
Table (4 entries) containing a list of names/IP addresses of workstations permitted to issue SET requests. Such a workstation is called a Set client. If this table is empty then any SET request with a matching SET community string is allowed. If at least one Set client is specified, then an incoming SET request must have its source IP address matched against an entry in this table before the SET is allowed.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MrNetMgmtSetClientEntry

mrNetMgmtSetClientEntry 1.3.6.1.4.1.9.2.11.1.4.17.1
A name/IP address of a manager station allowed to issue SET requests to this management agent.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  MrNetMgmtSetClientEntry  

mrNetMgmtSetClientIndex 1.3.6.1.4.1.9.2.11.1.4.17.1.1
Identifier of a particular table entry.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..4  

mrNetMgmtSetClientName 1.3.6.1.4.1.9.2.11.1.4.17.1.2
The Set Client's name or IP address. Default value: string of length 0.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString  

mrNetMgmtSetClientStatus 1.3.6.1.4.1.9.2.11.1.4.17.1.3
other(1) -- none of the following invalid(2) -- an invalid entry permanent(3) -- a valid entry that is in use Setting this object to the value invalid(2) has the effect of invalidating the corresponding entry. That is, it effectively disassociates the name/IP address identified with said entry from the table. It is an implementation- specific matter as to whether the agent removes an invalidated entry from the table. Accordingly, management stations must be prepared to receive tabular information from agents that corresponds to entries not currently in use. Default value: permanent(3).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER other(1), invalid(2), permanent(3)  

mrNetMgmtTrapClientTable 1.3.6.1.4.1.9.2.11.1.4.18
Table (4 entries) containing a list of Network Management Stations that are to receive traps generated by this Network Management Agent. Such an NMS is called a Trap client.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MrNetMgmtTrapClientEntry

mrNetMgmtTrapClientEntry 1.3.6.1.4.1.9.2.11.1.4.18.1
A destination address and community string to a particular trap client.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  MrNetMgmtTrapClientEntry  

mrNetMgmtTrapClientIndex 1.3.6.1.4.1.9.2.11.1.4.18.1.1
Identifier of a particular table entry.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..4  

mrNetMgmtTrapClientName 1.3.6.1.4.1.9.2.11.1.4.18.1.2
The Trap Client's name or IP address. Default value: string of length 0.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString  

mrNetMgmtTrapClientComm 1.3.6.1.4.1.9.2.11.1.4.18.1.3
The community string (up to 32 characters) used for traps sent to this Trap Client. Default value: string of length 0.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..32)  

mrNetMgmtTrapClientStatus 1.3.6.1.4.1.9.2.11.1.4.18.1.4
other(1) -- none of the following invalid(2) -- an invalid entry permanent(3) -- a valid entry that is in use Setting this object to the value invalid(2) has the effect of invalidating the corresponding entry. That is, it effectively disassociates the name/community string identified with said entry from the table. It is an implementation-specific matter as to whether the agent removes an invalidated entry from the table. Accordingly, management stations must be prepared to receive tabular information from agents that corresponds to entries not currently in use. Default value: permanent(3).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER other(1), invalid(2), permanent(3)  

mrUpgradeFlashSize 1.3.6.1.4.1.9.2.11.1.5.1
The size in kilobytes of FLASH memory installed in the system. For example: 128 equals 131072 bytes (128 times 1024 bytes). Default value: 1024 (one megabyte).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

mrUpgradeLastUpgradeTime 1.3.6.1.4.1.9.2.11.1.5.2
A string containing the date and time of the last upgrade of the primary Supervisor firmware. The string is in net ASCII and conforms exactly to one of the following format: 'Wed Dec 27 15:19:15 1995' Default value: string of length 0.
Status: obsolete Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

mrUpgradeLastUpgradeSource 1.3.6.1.4.1.9.2.11.1.5.3
The name or IP address of the TFTP node which last sent a Supervisor firmware image to upgrade the FLASH memory contents. If the last upgrade was from the RS-232 console, this object would contain 'console port' or 'diagnostic console port'. Default value: string of length 0.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

mrUpgradeLastUpgradeStatus 1.3.6.1.4.1.9.2.11.1.5.4
Indicates the status of the last upgrade. The object can have one of the following values: none(1), -- no upgrade has been done inProgress(2), -- upgrade still in progress success(3), -- last upgrade was successful failure(4) -- last upgrade failed Default value: none(1).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER none(1), inProgress(2), success(3), failure(4)  

mrUpgradeTFTPServerAddress 1.3.6.1.4.1.9.2.11.1.5.5
This object names the TFTP server from which a firmware file can be downloaded using the built-in TFTP protocol. This is the in-band system-directed upgrade method. The download may be initiated by setting the mrUpgradeTFTPInitiate to upgrade(1), or via an out-of-band management action. If the first non-blank character in mrUpgradeTFTPServerAddress is a NetASCII numeral, the name is assumed to be an IP address. Otherwise, the name is assumed to be a fully qualified Domain Name Server name, and the DNS protocol will be used to resolve it to an IP address. Default value: string of length 0.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString  

mrUpgradeTFTPLoadFilename 1.3.6.1.4.1.9.2.11.1.5.6
The name of the file containing a firmware upgrade image on the host whose address is given by mrUpgradeTFTPServerAddress. Default value: string of length 0.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..80)  

mrUpgradeTFTPInitiate 1.3.6.1.4.1.9.2.11.1.5.7
upgrade(1), -- no action noUpgrade(2) -- initiate an upgrade Setting this object to noUpgrade(2) results in no action. When set to upgrade(1), FastHub will attempt to download a firmware file whose name is given by mrUpgradeTFTPLoadFilename, from the server whose address is given by mrUpgradeTFTPServerAddress. Both mrUpgradeTFTPServerAddress and mrUpgradeTFTPLoadFilename must be non-empty for the upgrade to proceed. The object always returns noUpgrade(2) when read. Default value: noUpgrade(2).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER upgrade(1), noUpgrade(2)  

mrUpgradeTFTPAccept 1.3.6.1.4.1.9.2.11.1.5.8
enabled(1), -- accept TFTP upgrade request disabled(2) -- do not accept TFTP upgrade request When set to disabled(2), FastHub will refuse TFTP write requests from workstations. When enabled(1), a user at a workstations may send a firmware file using the TFTP protocol to upgrade the current primary Supervisor firmware. This is the in-band workstation-directed upgrade method. Default value: enabled(1).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

logonIntruder 0
A user is repeatedly trying to log on to the Management Console using an invalid password. The number of attempts exceeds the preset limit given in mrNetMgmtConsolePasswordThreshold. Depending on how the object mrNetMgmtConsoleSilentTime is configured, FastHub may shut down the Management Console following the generation of this trap.
TRAP-TYPE    

hubStackDiagnostic 1
FastHub issues this trap when its Power On Self Test (POST) code does not pass all tests. Some failures are catastrophic and may prevent the generation of this trap.
TRAP-TYPE    

rpsFailed 2
A redundant power source is connected to FastHub but a failure exists in the power system.
TRAP-TYPE    

ipAddressChange 3
The ipAddressChange trap is issued when the FastHub Supervisor is unable to complete its DHCPDISCOVER/ DHCPREQUEST process, or when it fails to extend the lease for the current address, or when it accepts an address change from the user.
TRAP-TYPE