CISCO-FABRIC-C12K-MIB

File: CISCO-FABRIC-C12K-MIB.mib (65919 bytes)

Imported modules

SNMPv2-SMI SNMPv2-TC SNMP-FRAMEWORK-MIB
SNMPv2-CONF ENTITY-MIB CISCO-TC
CISCO-SMI

Imported symbols

Counter32 Unsigned32 MODULE-IDENTITY
OBJECT-TYPE NOTIFICATION-TYPE TEXTUAL-CONVENTION
TruthValue SnmpAdminString MODULE-COMPLIANCE
NOTIFICATION-GROUP OBJECT-GROUP PhysicalIndex
entPhysicalIndex entPhysicalName EntPhysicalIndexOrZero
ciscoMgmt

Defined Types

CfcFabricConfigMode  
An enumerated value that provides the current bandwidth and redundancy configuration of the fabric. The c12000 can have the following fabric configurations based on the number of fabric cards present in the system. 1) Invalid configuration mode, this mode indicates that the current fabric mode is invalid, this may be due to insufficient number of CSC or SFC cards in the system. 2) Quarter bandwidth non-redundant mode, this mode indicates that the bandwidth supported per slot by the switch is 1/4 th of the full bandwidth and there is no redundancy for the fabric failure. 3) Quarter bandwidth redundant mode, this mode indicates that the bandwidth supported per slot by the switch is 1/4 th of the full bandwidth and there is redundancy for the fabric failure. 4) Full bandwidth non-redundant mode, this mode indicates that the full bandwidth is supported per slot by the switch and there is no redundancy for the fabric failure. 5) Full bandwidth redundant mode, this mode indicates that the full bandwidth is supported per slot by the switch and there is redundancy for the fabric failure. Quarter bandwidth modes are applicable only for the systems with pre-OC192 fabric cards.
TEXTUAL-CONVENTION    
  INTEGER invalidMode(1), quarterBwNonRedundant(2), quarterBwRedundant(3), fullBwNonRedundant(4), fullBwRedundant(5)  

CfcFabricFiaState  
Provides the current state of the FIA. active - FIA is currently active. halted - On reaching a test point for errors on FIA, the FIA will be moved to halted state. On clearance of the error state the FIA will be moved back to active state.
TEXTUAL-CONVENTION    
  INTEGER active(1), halted(2)  

CfcScaInterrupts  
Indicates different alarm conditions in the SCA. lossOfSync (0) -- Interrupt caused by a loss-of-sync detection by SCA. parityError (1) -- Interrupt caused by a request parity error detection by SCA. overflow (2) -- Interrupt caused by a request overflow detection.
TEXTUAL-CONVENTION    
  BITS lossOfSync(0), parityError(1), overflow(2)  

CfcSlotMask  
Each bit in this value is used to represent a module, where the bit position represents the slot number of the module. Ex: To represent a module which is in slot 1, the bit position 1 in the octet string is set.
TEXTUAL-CONVENTION    
  OCTET STRING Size(0..255)  

CfcGenericFabToFabEntry  
SEQUENCE    
  cfcGenericFabToFabState CfcFabricFiaState
  cfcGenericFabToFabGrantPEs Counter32
  cfcGenericFabToFabRequestPEs Counter32
  cfcGenericFabToFabCellFifoPEs Counter32

CfcGenericFabFrFabEntry  
SEQUENCE    
  cfcGenericFabFrFabState CfcFabricFiaState

CfcGenericFabFrFabSliEntry  
SEQUENCE    
  cfcGenericFabFrFabSliFabIndex PhysicalIndex
  cfcGenericFabFrFabSliLOSErrors Counter32
  cfcGenericFabFrFabSliCRCErrors Counter32
  cfcGenericFabFrFabSliLOSState INTEGER

CfcGenericScaEntry  
SEQUENCE    
  cfcGenericScaIdentifier SnmpAdminString
  cfcGenericScaIntrStatus CfcScaInterrupts
  cfcGenericScaIntrsEnabled CfcScaInterrupts
  cfcGenericScaConfig BITS
  cfcGenericScaPELog CfcSlotMask
  cfcGenericScaFifoOverflowLog CfcSlotMask
  cfcGenericScaLCsEnabled CfcSlotMask
  cfcGenericScaForcedBackPressure CfcSlotMask
  cfcGenericScaPreOc192LCsPresent CfcSlotMask
  cfcGenericScaOc192LCsPresent CfcSlotMask

CfcGenericXbarEntry  
SEQUENCE    
  cfcGenericXbarIdentifier SnmpAdminString

CfcPreOc192FabToFabEntry  
SEQUENCE    
  cfcPreOc192FabToFabScaLosts Counter32
  cfcPreOc192FabToFabUCFifoOvFlws Counter32
  cfcPreOc192FabToFabUCFifoUnFlws Counter32
  cfcPreOc192FabToFabMCFifoErrs Counter32
  cfcPreOc192FabToFabBmaPEs Counter32
  cfcPreOc192FabToFabBmaHskErrs Counter32
  cfcPreOc192FabToFabUniDestMCRqs Counter32
  cfcPreOc192FabToFabMultiDstUCRqs Counter32
  cfcPreOc192FabToFabEmptyDestRqs Counter32

CfcPreOc192FabFrFabEntry  
SEQUENCE    
  cfcPreOc192FabFrFabCellFifoPEs Counter32
  cfcPreOc192FabFrFabRedFifoPEs Counter32
  cfcPreOc192FabFrFabRedFifoOvflws Counter32
  cfcPreOc192FabFrFabCellDrops Counter32

CfcPreOc192ScaEntry  
SEQUENCE    
  cfcPreOc192ScaReSyncDelay Unsigned32
  cfcPreOc192ScaLOSLog CfcSlotMask

CfcPreOc192XbarEntry  
SEQUENCE    
  cfcPreOc192XbarIntrStatus BITS
  cfcPreOc192XbarParityChkStatus TruthValue

CfcOc192FabToFabEntry  
SEQUENCE    
  cfcOc192FabToFabMccDataPEs Counter32
  cfcOc192FabToFabMccCmdPEs Counter32
  cfcOc192FabToFabBackPressurePEs Counter32
  cfcOc192FabToFabCellFifoOvFlws Counter32
  cfcOc192FabToFabCellFifoUnFlws Counter32
  cfcOc192FabToFabMccCmdSeqEndErrs Counter32
  cfcOc192FabToFabMccCmdSeqStrErrs Counter32

CfcOc192FabFrFabEntry  
SEQUENCE    
  cfcOc192FabFrFabPktLenErrs Counter32
  cfcOc192FabFrFabExtRamPEs Counter32
  cfcOc192FabFrFabPktLenPEs Counter32
  cfcOc192FabFrFabHdrSramPEs Counter32
  cfcOc192FabFrFabTxCtrlPEs Counter32
  cfcOc192FabFrFabHdrFifoOvFlws Counter32
  cfcOc192FabFrFabExtSramOvFlws Counter32
  cfcOc192FabFrFabFirstLastErrs Counter32
  cfcOc192FabFrFabSeqErrs Counter32

CfcOc192FabFrFabSliEntry  
SEQUENCE    
  cfcOc192FabFrFabSliSwitchIndex PhysicalIndex
  cfcOc192FabFrFabSliXorErrs Counter32
  cfcOc192FabFrFabSliCellDrops Counter32

CfcOc192FabFrFabStatEntry  
SEQUENCE    
  cfcOc192FabFrFabStatLCIndex PhysicalIndex
  cfcOc192FabFrFabStatUCHiPktDrops Counter32
  cfcOc192FabFrFabStatUCLoPktDrops Counter32
  cfcOc192FabFrFabStatMCHiPktDrops Counter32
  cfcOc192FabFrFabStatMCLoPktDrops Counter32

CfcOc192ScaEntry  
SEQUENCE    
  cfcOc192ScaRotationPeriod Unsigned32
  cfcOc192ScaDisableGrants CfcSlotMask

CfcOc192XbarEntry  
SEQUENCE    
  cfcOc192XbarCtrlLOSStatus BITS
  cfcOc192XbarCtrlCRCErr BITS

Defined Values

ciscoFabricC12kMIB 1.3.6.1.4.1.9.9.281
Cisco Fabric MIB module for c12000 series of routers. This MIB module is used for managing/tracking the c12000 fabric entities and fabric related configuration, status and statistics information. C12000 fabric architecture is based on NxN non-blocking crossbar switch fabric, where N stands for the maximum number of LCs that can be supported in the chassis (this includes the RP). The connections through the switch fabric is controlled by a scheduler (CSC), the CSC accepts transmission requests from line cards, issues grants to access the fabric, and provides a reference clock to all the cards in the system to synchronize data transfer across the crossbar. Some of the error status objects in the MIB are read-clear, that is the value of the object is cleared on a query of the object. Details about the various fabric related attributes specified in the MIB could be found at following link, http://www.cisco.com/warp/public/108/hwts_12000_22281.html Acronyms and terms used in the MIB module: GSR - Gigabit Switch Router. RP - Route Processor. LC - Line Card. SFC - Switch Fabric Card. CRC - Cyclic Redundancy Check. CSC - Clock Scheduler Card. CiscoCell - The unit of data that is exchanged between line cards through the switch fabric. FIA - Fabric Interface Asic, this Asic resides on the line card and is used to interface line card and switch fabric. ToFabFIA - Represents the ToFabric FIA, FIA which transmits data from the line card to the fabric. FrFabFIA - Represents the From Fabric FIA, FIA which receives data from the fabric. SCA - Scheduler Control Asic, this Asic resides on each CSC and is used to arbitrate among the line card requests to transmit CiscoCells through the switch fabric. Xbar - Crossbar Switch Asic, this Asic resides on each fabric card and provides the functionality of a crossbar switch. SLI - Serial Link interface block, this block resides on the FIA on the line cards and the Xbar and SCA on the switch fabric. The functionality of SLI is to interface the linecards and fabric cards. BMA - Buffer Manager Asic, this Asic is located on a Pre OC-192 linecard. It provides the packet buffering and buffer queue management. MCC - Memory Communication Controller Asic, this Asic is located on a OC-192 linecard and is an enhanced packet buffer Asic. MCC captures the data and control path information for packets destined to all line cards in the system. On the receive side MCC interfaces with the Rx Asic where the packets are looked up and sent to the MCC for buffering. On the transmit side it interfaces with the ToFabFIA where packets arrived from MCC will be segmented into CiscoCells before being sent across the fabric. CSAR - Cisco Cell Segmentation And Reassembly, The name of an FPGA used on the RP which handles traffic between the processor and switch fabric. Request - A signal sent by a FIA (on a line card) to the SCA (on Master CSC) requesting a switch connection to a output linecard as an intent to transmit CiscoCells across. Grant - A signal sent by the SCA to a FIA (on a line card) granting a switch connection which was requested by the FIA. SRAM - Static Random Access Memory. LOS - Loss Of Signal. FPGA - Field Programmable Gate Array.
MODULE-IDENTITY    

ciscoFabricC12kMIBNotifs 1.3.6.1.4.1.9.9.281.0
OBJECT IDENTIFIER    

ciscoFabricC12kMIBObjects 1.3.6.1.4.1.9.9.281.1
OBJECT IDENTIFIER    

ciscoFabricC12kMIBConform 1.3.6.1.4.1.9.9.281.2
OBJECT IDENTIFIER    

cfcGeneric 1.3.6.1.4.1.9.9.281.1.1
OBJECT IDENTIFIER    

cfcGenericGlobal 1.3.6.1.4.1.9.9.281.1.1.1
OBJECT IDENTIFIER    

cfcGenericFab 1.3.6.1.4.1.9.9.281.1.1.2
OBJECT IDENTIFIER    

cfcGenericSca 1.3.6.1.4.1.9.9.281.1.1.3
OBJECT IDENTIFIER    

cfcGenericXbar 1.3.6.1.4.1.9.9.281.1.1.4
OBJECT IDENTIFIER    

cfcPreOc192 1.3.6.1.4.1.9.9.281.1.2
OBJECT IDENTIFIER    

cfcPreOc192Fab 1.3.6.1.4.1.9.9.281.1.2.1
OBJECT IDENTIFIER    

cfcPreOc192Sca 1.3.6.1.4.1.9.9.281.1.2.2
OBJECT IDENTIFIER    

cfcPreOc192Xbar 1.3.6.1.4.1.9.9.281.1.2.3
OBJECT IDENTIFIER    

cfcOc192 1.3.6.1.4.1.9.9.281.1.3
OBJECT IDENTIFIER    

cfcOc192Fab 1.3.6.1.4.1.9.9.281.1.3.1
OBJECT IDENTIFIER    

cfcOc192Sca 1.3.6.1.4.1.9.9.281.1.3.2
OBJECT IDENTIFIER    

cfcOc192Xbar 1.3.6.1.4.1.9.9.281.1.3.3
OBJECT IDENTIFIER    

cfcNotif 1.3.6.1.4.1.9.9.281.1.4
OBJECT IDENTIFIER    

cfcGenericGlobalFabConfigMode 1.3.6.1.4.1.9.9.281.1.1.1.1
This object gives the current bandwidth and redundancy configuration of fabric in the system.
Status: current Access: read-only
OBJECT-TYPE    
  CfcFabricConfigMode  

cfcGenericGlobalFabMasterSched 1.3.6.1.4.1.9.9.281.1.1.1.2
This object gives the entPhysicalIndex of the master scheduler fabric card in the system. If there is no master scheduler card then this object will return the value zero.
Status: current Access: read-only
OBJECT-TYPE    
  EntPhysicalIndexOrZero  

cfcGenericFabToFabTable 1.3.6.1.4.1.9.9.281.1.1.2.1
A table providing ToFabFIA statistics and information in the managed system.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    CfcGenericFabToFabEntry

cfcGenericFabToFabEntry 1.3.6.1.4.1.9.9.281.1.1.2.1.1
An entry providing various ToFabFIA statistics and information of the associated linecard identified by entPhysicalIndex.
Status: current Access: not-accessible
OBJECT-TYPE    
  CfcGenericFabToFabEntry  

cfcGenericFabToFabState 1.3.6.1.4.1.9.9.281.1.1.2.1.1.1
Indicates the current state of the ToFabFIA. active - ToFabFIA is currently active. On reaching a test point for the FIA errors, the ToFabFIA will be moved to halted state.
Status: current Access: read-only
OBJECT-TYPE    
  CfcFabricFiaState  

cfcGenericFabToFabGrantPEs 1.3.6.1.4.1.9.9.281.1.1.2.1.1.2
Count of parity errors detected by the ToFabFIA on the grant lines to SCA.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cfcGenericFabToFabRequestPEs 1.3.6.1.4.1.9.9.281.1.1.2.1.1.3
Count of parity errors detected by the ToFabFIA on the request lines to SCA. These errors are detected by the SCA and fed back to the ToFabFIA.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cfcGenericFabToFabCellFifoPEs 1.3.6.1.4.1.9.9.281.1.1.2.1.1.4
Count of cell parity errors detected by the ToFabFIA while dequeuing cells from the cell fifo.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cfcGenericFabFrFabTable 1.3.6.1.4.1.9.9.281.1.1.2.2
A table providing FrFabFIA information in the managed system.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    CfcGenericFabFrFabEntry

cfcGenericFabFrFabEntry 1.3.6.1.4.1.9.9.281.1.1.2.2.1
An entry providing FrFabFIA information of the associated linecard identified by entPhysicalIndex.
Status: current Access: not-accessible
OBJECT-TYPE    
  CfcGenericFabFrFabEntry  

cfcGenericFabFrFabState 1.3.6.1.4.1.9.9.281.1.1.2.2.1.1
Indicates the current state of the FrFabFIA. active - FrFabFIA is currently active. On reaching a test point for the FIA errors, the FrFabFIA will be moved to halted state
Status: current Access: read-only
OBJECT-TYPE    
  CfcFabricFiaState  

cfcGenericFabFrFabSliTable 1.3.6.1.4.1.9.9.281.1.1.2.3
A table providing per serial link information maintained by the FrFabFIA in the managed system.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    CfcGenericFabFrFabSliEntry

cfcGenericFabFrFabSliEntry 1.3.6.1.4.1.9.9.281.1.1.2.3.1
An entry providing per serial link information maintained by the FrFabFIA on an associated linecard.
Status: current Access: not-accessible
OBJECT-TYPE    
  CfcGenericFabFrFabSliEntry  

cfcGenericFabFrFabSliFabIndex 1.3.6.1.4.1.9.9.281.1.1.2.3.1.1
The entPhysicalIndex of the switch fabric cards (CSC/SFC) present in the monitored system.
Status: current Access: not-accessible
OBJECT-TYPE    
  PhysicalIndex  

cfcGenericFabFrFabSliLOSErrors 1.3.6.1.4.1.9.9.281.1.1.2.3.1.2
Count of LOS errors detected by the FrFabFIA on the serial link to the fabric card identified by cfcGenericFabFrFabSliFabIndex.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cfcGenericFabFrFabSliCRCErrors 1.3.6.1.4.1.9.9.281.1.1.2.3.1.3
Count of CRC errors detected by the FrFabFIA on the serial link to the fabric card identified by cfcGenericFabFrFabSliFabIndex.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cfcGenericFabFrFabSliLOSState 1.3.6.1.4.1.9.9.281.1.1.2.3.1.4
State of LOS detection as enabled on FrFabFIA (identified by entPhysicalIndex) for the serial link to the switch fabric card identified by cfcGenericFabFrFabSliFabIndex. Value is either, (1) losOff (2) losOn A losOff state normally indicates that the FrFabFIA has detected a state of persisting LOS on the serial link and has disabled LOS detection for that serial link.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER losOff(1), losOn(2)  

cfcGenericScaTable 1.3.6.1.4.1.9.9.281.1.1.3.1
A table providing SCA statistics and information in the managed system.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    CfcGenericScaEntry

cfcGenericScaEntry 1.3.6.1.4.1.9.9.281.1.1.3.1.1
An entry providing various statistics and information of SCA on an associated CSC identified by the respective entPhysicalIndex.
Status: current Access: not-accessible
OBJECT-TYPE    
  CfcGenericScaEntry  

cfcGenericScaIdentifier 1.3.6.1.4.1.9.9.281.1.1.3.1.1.1
The vendor-specific identifier string of SCA ASIC. This identifier generally includes the revision number and the manufacturing part number of SCA.
Status: current Access: read-only
OBJECT-TYPE    
  SnmpAdminString  

cfcGenericScaIntrStatus 1.3.6.1.4.1.9.9.281.1.1.3.1.1.2
Gives the status/occurrence of different alarm conditions in the SCA. This object is a read-clear object, that is the value of the object is cleared on every read.
Status: current Access: read-only
OBJECT-TYPE    
  CfcScaInterrupts  

cfcGenericScaIntrsEnabled 1.3.6.1.4.1.9.9.281.1.1.3.1.1.3
Gives the list of different alarm conditions enabled to be generated by the SCA.
Status: current Access: read-only
OBJECT-TYPE    
  CfcScaInterrupts  

cfcGenericScaConfig 1.3.6.1.4.1.9.9.281.1.1.3.1.1.4
Gives the current configuration of the SCA ASIC. quarterBandwidth (0) -- 1/4th of the full bandwidth is supported per slot by the switch. halfBandwidth (1) -- 1/2th of the full bandwidth is supported per slot by the switch. fullBandwidth (2) -- Full bandwidth is supported per slot by the switch. enableParity (3) -- Parity handling by SCA is enabled. priMcast (4) -- Priority of Multicast requests is greater then Unicast requests. priUnicast (5) -- Priority of Unicast requests is greater then Multicast requests. priAlternating (6) -- Alternate the priority between pri-mcast and pri-unicast modes every cell clock. earlyIntrOnLOS (7) -- Cause early interrupt on loss-of-sync error. noEarlyIntrOnLOS (8) -- Allow time to resync on loss-of-sync error. forceXbarParityXer (9) -- Force bad parity on xbar on every cell clock. forceGrantParityXer (10) -- Force bad partity on grant to every line card. unicastAcceptMode (11) -- Enable unicast accept pointer updating only on cell periods when Unicast has higher priority over multicast. forceXbarCrcOnCtlLink0 (12)-- Force CRC error on Xbar control link 0. forceXbarCrcOnCtlLink0 (13)-- Force CRC error on Xbar control link 1. forceXbarCrcOnCtlLink0 (14)-- Force CRC error on Xbar control link 2. forceXbarCrcOnCtlLink0 (15)-- Force CRC error on Xbar control link 3.
Status: current Access: read-only
OBJECT-TYPE    
  BITS quarterBandwidth(0), halfBandwidth(1), fullBandwidth(2), enableParity(3), priMcast(4), priUnicast(5), priAlternating(6), earlyIntrOnLOS(7), noEarlyIntrOnLOS(8), forceXbarParityXer(9), forceGrantParityXer(10), unicastAcceptMode(11), forceXbarCrcOnCtlLink0(12), forceXbarCrcOnCtlLink1(13), forceXbarCrcOnCtlLink2(14), forceXbarCrcOnCtlLink3(15)  

cfcGenericScaPELog 1.3.6.1.4.1.9.9.281.1.1.3.1.1.5
Indicates the modules which caused the parity error and resulted in an interrupt. The corresponding bit is set on occurrence of parity error for a module. This object is a read-clear object, that is the value of the object is cleared on every read.
Status: current Access: read-only
OBJECT-TYPE    
  CfcSlotMask  

cfcGenericScaFifoOverflowLog 1.3.6.1.4.1.9.9.281.1.1.3.1.1.6
Indicates the modules which caused an overflow at the request fifo and resulted in an interrupt. The corresponding bit is set on occurrence of fifo overflow for a module. This object is a read-clear object, that is the value of the object is cleared on every read.
Status: current Access: read-only
OBJECT-TYPE    
  CfcSlotMask  

cfcGenericScaLCsEnabled 1.3.6.1.4.1.9.9.281.1.1.3.1.1.7
Indicates the modules which are present and the SCA has been configured to start accepting requests from this module.
Status: current Access: read-only
OBJECT-TYPE    
  CfcSlotMask  

cfcGenericScaForcedBackPressure 1.3.6.1.4.1.9.9.281.1.1.3.1.1.8
Indicates the linecards which exerted backpressure. SCA will not grant Xbar connection to these linecards.
Status: current Access: read-only
OBJECT-TYPE    
  CfcSlotMask  

cfcGenericScaOc192LCsPresent 1.3.6.1.4.1.9.9.281.1.1.3.1.1.9
Indicates the OC192 linecards present in the monitored system. The corresponding bit is set for each linecard present, indicating the postion.
Status: current Access: read-only
OBJECT-TYPE    
  CfcSlotMask  

cfcGenericScaPreOc192LCsPresent 1.3.6.1.4.1.9.9.281.1.1.3.1.1.10
Indicates the Pre-OC192 linecards present in the monitored system. The corresponding bit is set for each linecard present, indicating the position.
Status: current Access: read-only
OBJECT-TYPE    
  CfcSlotMask  

cfcGenericXbarTable 1.3.6.1.4.1.9.9.281.1.1.4.1
A table providing Xbar information in the managed system.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    CfcGenericXbarEntry

cfcGenericXbarEntry 1.3.6.1.4.1.9.9.281.1.1.4.1.1
An entry providing Xbar information on an associated fabric card identified by entPhysicalIndex.
Status: current Access: not-accessible
OBJECT-TYPE    
  CfcGenericXbarEntry  

cfcGenericXbarIdentifier 1.3.6.1.4.1.9.9.281.1.1.4.1.1.1
The vendor-specific identifier string of Xbar ASIC. This identifier generally includes the revision number and the manufacturing part number of Xbar.
Status: current Access: read-only
OBJECT-TYPE    
  SnmpAdminString  

cfcPreOc192FabToFabTable 1.3.6.1.4.1.9.9.281.1.2.1.1
A table providing pre-OC192 ToFabFIA statistics and information in the managed system.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    CfcPreOc192FabToFabEntry

cfcPreOc192FabToFabEntry 1.3.6.1.4.1.9.9.281.1.2.1.1.1
An entry providing various statistics and counters of pre-OC192 ToFabFIA on an associated linecard identified by entPhysicalIndex.
Status: current Access: not-accessible
OBJECT-TYPE    
  CfcPreOc192FabToFabEntry  

cfcPreOc192FabToFabScaLosts 1.3.6.1.4.1.9.9.281.1.2.1.1.1.1
Indicates the number of times the ToFabFIA lost contact with SCA(scheduler controller Asic) on master CSC.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cfcPreOc192FabToFabUCFifoOvFlws 1.3.6.1.4.1.9.9.281.1.2.1.1.1.2
Count of unicast fifo overflow errors on the ToFabFIA. Problems between BMA/CSAR and the ToFabFIA may be one of the reasons for these errors.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cfcPreOc192FabToFabUCFifoUnFlws 1.3.6.1.4.1.9.9.281.1.2.1.1.1.3
Count of unicast fifo underflow errors on the ToFabFIA. These errors are caused by the SCA granting without actually getting a request from the ToFabFIA.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cfcPreOc192FabToFabMCFifoErrs 1.3.6.1.4.1.9.9.281.1.2.1.1.1.4
Count of multicast fifo overflow and underflow errors on the ToFabFIA. Problems between BMA/CSAR and the ToFabFIA may be one of the reasons for multicast fifo overflow errors. Underflow errors are caused by the SCA granting without actually getting a request from the ToFabFIA.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cfcPreOc192FabToFabBmaPEs 1.3.6.1.4.1.9.9.281.1.2.1.1.1.5
Count of parity errors on cells received from BMA by the ToFabFIA.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cfcPreOc192FabToFabBmaHskErrs 1.3.6.1.4.1.9.9.281.1.2.1.1.1.6
Count of handshake errors between the BMA/CSAR and the ToFabFIA.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cfcPreOc192FabToFabUniDestMCRqs 1.3.6.1.4.1.9.9.281.1.2.1.1.1.7
Count of requests with single destination in a multicast request detected by ToFabFIA. The FIA will send this cell to the destination.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cfcPreOc192FabToFabMultiDstUCRqs 1.3.6.1.4.1.9.9.281.1.2.1.1.1.8
Count of requests with multiple destinations in a unicast request detected by a ToFabFIA. The FIA will drop this cell.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cfcPreOc192FabToFabEmptyDestRqs 1.3.6.1.4.1.9.9.281.1.2.1.1.1.9
Count of requests with empty destination detected by ToFabFIA. The FIA will drop this cell.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cfcPreOc192FabFrFabTable 1.3.6.1.4.1.9.9.281.1.2.1.2
A table providing pre-OC192 FrFabFIA statistics and information in the managed system.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    CfcPreOc192FabFrFabEntry

cfcPreOc192FabFrFabEntry 1.3.6.1.4.1.9.9.281.1.2.1.2.1
An entry providing various statistics and information of pre-OC192 FrFabFIA on an associated linecard identified by entPhysicalIndex.
Status: current Access: not-accessible
OBJECT-TYPE    
  CfcPreOc192FabFrFabEntry  

cfcPreOc192FabFrFabCellFifoPEs 1.3.6.1.4.1.9.9.281.1.2.1.2.1.1
Count of cisco cell fifo parity errors detected by the FrFabFIA while dequeuing cells from the cell fifo.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cfcPreOc192FabFrFabRedFifoPEs 1.3.6.1.4.1.9.9.281.1.2.1.2.1.2
Count of redundant data fifo parity errors detected by the FrFabFIA.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cfcPreOc192FabFrFabRedFifoOvflws 1.3.6.1.4.1.9.9.281.1.2.1.2.1.3
Count of redundant data fifo overflow errors detected by the FrFabFIA. This is caused if the back pressure is broken (i.e. the FrFabFIA exerts back pressure and the SCA keeps giving more data to it).
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cfcPreOc192FabFrFabCellDrops 1.3.6.1.4.1.9.9.281.1.2.1.2.1.4
Count of number of cells dropped by the FrFabFIA. In case of non-redundant fabric configuration, cell drops can occur when a parity error is detected on one or more than one serial link. In case of redundant fabric configuration cell drops can occur when a cell gets corrupted on more than one serial link.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cfcPreOc192ScaTable 1.3.6.1.4.1.9.9.281.1.2.2.1
A table providing pre-OC192 SCA statistics and information in the managed system.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    CfcPreOc192ScaEntry

cfcPreOc192ScaEntry 1.3.6.1.4.1.9.9.281.1.2.2.1.1
An entry providing various statistics and information of pre-OC192 SCA on an associated CSC identified by entPhysicalIndex.
Status: current Access: not-accessible
OBJECT-TYPE    
  CfcPreOc192ScaEntry  

cfcPreOc192ScaReSyncDelay 1.3.6.1.4.1.9.9.281.1.2.2.1.1.1
The number of cell periods that the SCA will allow the serial links connected to a module and Xbar to be resynced, if a loss-of-sync has occurred on the corresponding module. The value '0' indicates that on occurrence of LOS, the sca will only log the LOS event and do the scheduling for that module as normal.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

cfcPreOc192ScaLOSLog 1.3.6.1.4.1.9.9.281.1.2.2.1.1.2
Indicates the LOS event occurrence on each linecard connected to this CSC. The corresponding bit is set on occurrence of LOS event on a line card. This object is a read-clear object, that is the value of the object is cleared on every read.
Status: current Access: read-only
OBJECT-TYPE    
  CfcSlotMask  

cfcPreOc192XbarTable 1.3.6.1.4.1.9.9.281.1.2.3.1
A table providing Pre-OC192 Xbar statistics and information in the managed system.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    CfcPreOc192XbarEntry

cfcPreOc192XbarEntry 1.3.6.1.4.1.9.9.281.1.2.3.1.1
An entry providing various statistics and information of Pre-OC192 Xbar on an associated fabric card identified by entPhysicalIndex.
Status: current Access: not-accessible
OBJECT-TYPE    
  CfcPreOc192XbarEntry  

cfcPreOc192XbarIntrStatus 1.3.6.1.4.1.9.9.281.1.2.3.1.1.1
Indicates the occurrence of different alarm conditions in Xbar. This object is a read-clear object, that is the value of the object is cleared on every read.
Status: current Access: read-only
OBJECT-TYPE    
  BITS frameLossOfSync(0), parityErrorFromSca(1)  

cfcPreOc192XbarParityChkStatus 1.3.6.1.4.1.9.9.281.1.2.3.1.1.2
Indicates the parity check state in control data received from SCA to the Xbar. true(1) indicates that the parity check is enabled. false(2) indicates that the parity check is disabled.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

cfcOc192FabToFabTable 1.3.6.1.4.1.9.9.281.1.3.1.1
A table providing OC192 ToFabFIA statistics and information in the managed system.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    CfcOc192FabToFabEntry

cfcOc192FabToFabEntry 1.3.6.1.4.1.9.9.281.1.3.1.1.1
An entry providing various statistics and information of OC192 ToFabFIA on an associated linecard identified by entPhysicalIndex.
Status: current Access: not-accessible
OBJECT-TYPE    
  CfcOc192FabToFabEntry  

cfcOc192FabToFabMccDataPEs 1.3.6.1.4.1.9.9.281.1.3.1.1.1.1
Count of the parity errors on data lines from MCC to ToFabFIA. This error would cause the ToFabFIA to halt.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cfcOc192FabToFabMccCmdPEs 1.3.6.1.4.1.9.9.281.1.3.1.1.1.2
Count of the parity errors on command lines from MCC to ToFabFIA. This error would cause the ToFabFIA to halt.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cfcOc192FabToFabBackPressurePEs 1.3.6.1.4.1.9.9.281.1.3.1.1.1.3
Count of the parity errors on back pressure line from FrFabFIA to ToFabFIA. This error would cause the ToFabFIA to halt.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cfcOc192FabToFabCellFifoOvFlws 1.3.6.1.4.1.9.9.281.1.3.1.1.1.4
Count of the cell fifo overflow errors detected by the ToFabFIA. This error would cause the ToFabFIA to halt.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cfcOc192FabToFabCellFifoUnFlws 1.3.6.1.4.1.9.9.281.1.3.1.1.1.5
Count of the cell fifo underflow errors detected by the ToFabFIA. This error would cause the ToFabFIA to halt.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cfcOc192FabToFabMccCmdSeqEndErrs 1.3.6.1.4.1.9.9.281.1.3.1.1.1.6
Count of the illegal sequence of command errors where a middle or start command followed by a start command is received from MCC.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cfcOc192FabToFabMccCmdSeqStrErrs 1.3.6.1.4.1.9.9.281.1.3.1.1.1.7
Count of the illegal sequence of command errors where an end command followed by an end or middle command is received from MCC.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cfcOc192FabFrFabTable 1.3.6.1.4.1.9.9.281.1.3.1.2
A table providing FrFabFIA statistics and information in the managed system.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    CfcOc192FabFrFabEntry

cfcOc192FabFrFabEntry 1.3.6.1.4.1.9.9.281.1.3.1.2.1
An entry providing various statistics and information of OC192 FrFabFIA on an associated linecard identified by entPhysicalIndex.
Status: current Access: not-accessible
OBJECT-TYPE    
  CfcOc192FabFrFabEntry  

cfcOc192FabFrFabPktLenErrs 1.3.6.1.4.1.9.9.281.1.3.1.2.1.1
Count of the packets (after reassembly from Cisco cells) which exceed the maximum permitted packet length of FrFabFIA. These packets will be dropped.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cfcOc192FabFrFabExtRamPEs 1.3.6.1.4.1.9.9.281.1.3.1.2.1.2
Count of the parity errors detected in FrFabFIA's external SRAM.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cfcOc192FabFrFabPktLenPEs 1.3.6.1.4.1.9.9.281.1.3.1.2.1.3
Count of the parity errors detected in payload packet length field of the FrFabFIA's Payload Header SRAM.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cfcOc192FabFrFabHdrSramPEs 1.3.6.1.4.1.9.9.281.1.3.1.2.1.4
Count of the parity errors detected in payload header field of the FrFabFIA's Payload Header SRAM.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cfcOc192FabFrFabTxCtrlPEs 1.3.6.1.4.1.9.9.281.1.3.1.2.1.5
Count of the parity errors detected on the Tx control bits of FrFabFIA.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cfcOc192FabFrFabHdrFifoOvFlws 1.3.6.1.4.1.9.9.281.1.3.1.2.1.6
Count of the overflow errors in the FrFabFIA's reassembly fifos in the on-chip payload header SRAM.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cfcOc192FabFrFabExtSramOvFlws 1.3.6.1.4.1.9.9.281.1.3.1.2.1.7
Count of the overflow errors in the FrFabFIA's reassembly external SRAM's payload fifos.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cfcOc192FabFrFabFirstLastErrs 1.3.6.1.4.1.9.9.281.1.3.1.2.1.8
Count of the First-Last errors detected by FrFabFIA's. If a first cell is received for a reassembly fifo, while an earlier packet in the same reassembly fifo is still waiting for its last cell, then it is called a First-Last Error.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cfcOc192FabFrFabSeqErrs 1.3.6.1.4.1.9.9.281.1.3.1.2.1.9
Count of the sequence errors detected by FrFabFIA in the cells received for reassembly. If a cell is received whose sequence number is not an unit increment from the previous cell of the same packet then it is a sequence error.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cfcOc192FabFrFabSliTable 1.3.6.1.4.1.9.9.281.1.3.1.3
A table providing per serial link information maintained by the OC192 FrFabFIA in the managed system.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    CfcOc192FabFrFabSliEntry

cfcOc192FabFrFabSliEntry 1.3.6.1.4.1.9.9.281.1.3.1.3.1
An entry providing per serial link information maintained by the OC192 FrFabFIA on an associated linecard identified by entPhysicalIndex.
Status: current Access: not-accessible
OBJECT-TYPE    
  CfcOc192FabFrFabSliEntry  

cfcOc192FabFrFabSliSwitchIndex 1.3.6.1.4.1.9.9.281.1.3.1.3.1.1
The entPhysicalIndex of the switch fabric cards (CSC/SFC) present in the monitored system.
Status: current Access: not-accessible
OBJECT-TYPE    
  PhysicalIndex  

cfcOc192FabFrFabSliXorErrs 1.3.6.1.4.1.9.9.281.1.3.1.3.1.2
Count of the XOR check errors detected by FrFabFIA reassembly. The data paths are horizontally XORed and the result is expected to match the contents of the redundant path else it is counted as XOR error, this error applies only in redundant mode of fabric.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cfcOc192FabFrFabSliCellDrops 1.3.6.1.4.1.9.9.281.1.3.1.3.1.3
Count of the total cells dropped by the FrFabFIA from the fabric card due to uncorrectable errors. Uncorrectable errors are the errors other than CRC, LOS, Horizontal XOR and idle cell which cannot be corrected.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cfcOc192FabFrFabStatTable 1.3.6.1.4.1.9.9.281.1.3.1.4
A table providing per module statistics information maintained by the OC192 FrFabFIA in the managed system.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    CfcOc192FabFrFabStatEntry

cfcOc192FabFrFabStatEntry 1.3.6.1.4.1.9.9.281.1.3.1.4.1
An entry providing per module statistics information maintained by the OC192 FrFabFIA on an associated linecard identified by entPhysicalIndex.
Status: current Access: not-accessible
OBJECT-TYPE    
  CfcOc192FabFrFabStatEntry  

cfcOc192FabFrFabStatLCIndex 1.3.6.1.4.1.9.9.281.1.3.1.4.1.1
The entPhysicalIndex of the Line card present in the monitored system.
Status: current Access: not-accessible
OBJECT-TYPE    
  PhysicalIndex  

cfcOc192FabFrFabStatUCHiPktDrops 1.3.6.1.4.1.9.9.281.1.3.1.4.1.2
Count of Unicast high priority packets dropped, from source module indicated by cfcOc192FabFrFabStatLCIndex.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cfcOc192FabFrFabStatUCLoPktDrops 1.3.6.1.4.1.9.9.281.1.3.1.4.1.3
Count of Unicast low priority packets dropped, from source module indicated by cfcOc192FabFrFabStatLCIndex.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cfcOc192FabFrFabStatMCHiPktDrops 1.3.6.1.4.1.9.9.281.1.3.1.4.1.4
Count of Multicast high priority packets dropped, from source module indicated by cfcOc192FabFrFabStatLCIndex.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cfcOc192FabFrFabStatMCLoPktDrops 1.3.6.1.4.1.9.9.281.1.3.1.4.1.5
Count of Multicast low priority packets dropped, from source module indicated by cfcOc192FabFrFabStatLCIndex.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cfcOc192ScaTable 1.3.6.1.4.1.9.9.281.1.3.2.1
A table providing OC192 SCA statistics and information in the managed system.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    CfcOc192ScaEntry

cfcOc192ScaEntry 1.3.6.1.4.1.9.9.281.1.3.2.1.1
An entry providing various statistics and information of OC192 SCA on an associated CSC identified by entPhysicalIndex.
Status: current Access: not-accessible
OBJECT-TYPE    
  CfcOc192ScaEntry  

cfcOc192ScaRotationPeriod 1.3.6.1.4.1.9.9.281.1.3.2.1.1.1
Determines the period of rotating the priority between Unicast and Multicast, in cell periods, when the SCA is configured with alternating priority mode. For example, if the value of this object is 63 then the priority will change every 64 cell periods, if the value is 0 then the priority will change every cell period.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

cfcOc192ScaDisableGrants 1.3.6.1.4.1.9.9.281.1.3.2.1.1.2
Indicates the disable of grants by SCA to any requests coming from a specific module. The corresponding bit is set for each module.
Status: current Access: read-only
OBJECT-TYPE    
  CfcSlotMask  

cfcOc192XbarTable 1.3.6.1.4.1.9.9.281.1.3.3.1
A table providing OC192 Xbar statistics and information in the managed system.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    CfcOc192XbarEntry

cfcOc192XbarEntry 1.3.6.1.4.1.9.9.281.1.3.3.1.1
An entry providing various statistics and information of OC192 Xbar on an associated fabric card identified by entPhysicalIndex.
Status: current Access: not-accessible
OBJECT-TYPE    
  CfcOc192XbarEntry  

cfcOc192XbarCtrlLOSStatus 1.3.6.1.4.1.9.9.281.1.3.3.1.1.1
Indicates the occurrence of LOS errors on the control path of Xbar. frameLosErr (0) -- Frame LOS error. sliErrorOnControlLink0 (1) -- LOS detected on SLI control link 0. sliErrorOnControlLink1 (2) -- LOS detected on SLI control link 1. sliErrorOnControlLink2 (3) -- LOS detected on SLI control link 2. sliErrorOnControlLink3 (4) -- LOS detected on SLI control link 3. This object is a read-clear object, that is the value of the object is cleared on every read.
Status: current Access: read-only
OBJECT-TYPE    
  BITS frameLosErr(0), sliErrorOnControlLink0(1), sliErrorOnControlLink1(2), sliErrorOnControlLink2(3), sliErrorOnControlLink3(4)  

cfcOc192XbarCtrlCRCErr 1.3.6.1.4.1.9.9.281.1.3.3.1.1.2
Indicates the occurrence of CRC error on any of the four control links. This object is a read-clear object, that is the value of the object is cleared on every read.
Status: current Access: read-only
OBJECT-TYPE    
  BITS ctlCrcErrorLink0(0), ctlCrcErrorLink1(1), ctlCrcErrorLink2(2), ctlCrcErrorLink3(3)  

cfcNotifEnable 1.3.6.1.4.1.9.9.281.1.4.1
This variable indicates whether the system produces the notifications defined in the MIB. A false value will prevent the notifications in the MIB from being generated by the system.
Status: current Access: read-write
OBJECT-TYPE    
  TruthValue  

ciscoFabricC12kMIBFabMasterSchCh 1.3.6.1.4.1.9.9.281.0.1
This notification is generated when master scheduler on the system changes. It typically indicates the switchover of the scheduler card. cfcGenericGlobalFabMasterSched represents the entPhysicalIndex of the new master scheduler card, while entPhysicalName represents the entity physical name of the card. The case of all scheduler cards going down would be represented by a value 0 for the cfcGenericGlobalFabMasterSched and noSuchInstance for the entPhysicalName.
Status: current Access: read-write
NOTIFICATION-TYPE    

ciscoFabricC12kMIBCompliances 1.3.6.1.4.1.9.9.281.2.1
OBJECT IDENTIFIER    

ciscoFabricC12kMIBGroups 1.3.6.1.4.1.9.9.281.2.2
OBJECT IDENTIFIER    

ciscoFabricC12kMIBCompliance 1.3.6.1.4.1.9.9.281.2.1.1
The compliance statement for entities which implement the CISCO-FABRIC-C12K-MIB.
Status: current Access: read-write
MODULE-COMPLIANCE    

ciscoFabricC12kGlobalGroup 1.3.6.1.4.1.9.9.281.2.2.1
A collection of Global fabric configuration objects.
Status: current Access: read-write
OBJECT-GROUP    

ciscoFabricC12kFiaGroup 1.3.6.1.4.1.9.9.281.2.2.2
A collection of generic FIA status and statistics objects.
Status: current Access: read-write
OBJECT-GROUP    

ciscoFabricC12kScaGroup 1.3.6.1.4.1.9.9.281.2.2.3
A collection of generic SCA status objects.
Status: current Access: read-write
OBJECT-GROUP    

ciscoFabricC12kXbarGroup 1.3.6.1.4.1.9.9.281.2.2.4
A collection of generic Xbar status objects.
Status: current Access: read-write
OBJECT-GROUP    

ciscoFabricC12kPreOc192FiaGroup 1.3.6.1.4.1.9.9.281.2.2.5
A collection of pre-OC192 FIA status and statistics objects.
Status: current Access: read-write
OBJECT-GROUP    

ciscoFabricC12kPreOc192ScaGroup 1.3.6.1.4.1.9.9.281.2.2.6
A collection of Pre-OC192 SCA status objects.
Status: current Access: read-write
OBJECT-GROUP    

ciscoFabricC12kPreOc192XbarGroup 1.3.6.1.4.1.9.9.281.2.2.7
A collection of Pre-Oc192 Xbar status objects.
Status: current Access: read-write
OBJECT-GROUP    

ciscoFabricC12kOc192FiaGroup 1.3.6.1.4.1.9.9.281.2.2.8
A collection of OC192 FIA status and statistics objects.
Status: current Access: read-write
OBJECT-GROUP    

ciscoFabricC12kOc192LCGroup 1.3.6.1.4.1.9.9.281.2.2.9
A collection of OC192 linecard generic objects.
Status: current Access: read-write
OBJECT-GROUP    

ciscoFabricC12kOc192ScaGroup 1.3.6.1.4.1.9.9.281.2.2.10
A collection of OC192 SCA status objects.
Status: current Access: read-write
OBJECT-GROUP    

ciscoFabricC12kOc192XbarGroup 1.3.6.1.4.1.9.9.281.2.2.11
A collection of OC192 Xbar status objects.
Status: current Access: read-write
OBJECT-GROUP    

ciscoFabricC12kNotifEnableGroup 1.3.6.1.4.1.9.9.281.2.2.12
The collection of objects which are used to control generation of notification.
Status: current Access: read-write
OBJECT-GROUP    

ciscoFabricC12kNotifGroup 1.3.6.1.4.1.9.9.281.2.2.13
A collection of notifications generated by the devices supporting this MIB.
Status: current Access: read-write
NOTIFICATION-GROUP