CISCO-ENTITY-EXT-MIB

File: CISCO-ENTITY-EXT-MIB.mib (47953 bytes)

Imported modules

SNMPv2-SMI SNMPv2-CONF SNMPv2-TC
SNMP-FRAMEWORK-MIB ENTITY-MIB CISCO-TC
CISCO-SMI

Imported symbols

MODULE-IDENTITY OBJECT-TYPE Unsigned32
NOTIFICATION-TYPE MODULE-COMPLIANCE OBJECT-GROUP
NOTIFICATION-GROUP TEXTUAL-CONVENTION TruthValue
SnmpAdminString entPhysicalIndex entPhysicalEntry
entPhysicalDescr entPhysicalName entPhysicalContainedIn
Unsigned64 ciscoMgmt

Defined Types

ConfigRegisterValue  
TEXTUAL-CONVENTION    
  current STRING Size(2)

BootImageList  
TEXTUAL-CONVENTION    
  current STRING Size(0..255)

CeExtPhysicalProcessorEntry  
SEQUENCE    
  ceExtProcessorRam Unsigned32
  ceExtNVRAMSize Unsigned32
  ceExtNVRAMUsed Unsigned32
  ceExtProcessorRamOverflow Unsigned32
  ceExtHCProcessorRam Unsigned64

CeExtConfigRegEntry  
SEQUENCE    
  ceExtConfigRegister ConfigRegisterValue
  ceExtConfigRegNext ConfigRegisterValue
  ceExtSysBootImageList BootImageList
  ceExtKickstartImageList BootImageList

CeExtEntityLEDEntry  
SEQUENCE    
  ceExtEntityLEDType INTEGER
  ceExtEntityLEDColor INTEGER

CeExtEntPhysicalEntry  
SEQUENCE    
  ceEntPhysicalSecondSerialNum SnmpAdminString

CeExtUSBModemEntry  
SEQUENCE    
  ceExtUSBModemIMEI SnmpAdminString
  ceExtUSBModemIMSI SnmpAdminString
  ceExtUSBModemServiceProvider SnmpAdminString
  ceExtUSBModemSignalStrength SnmpAdminString

Defined Values

ciscoEntityExtMIB 1.3.6.1.4.1.9.9.195
This MIB is an extension of the ENTITY-MIB specified in RFC2737. This MIB module contains Cisco-defined extensions to the entityPhysicalTable to represent information related to entities of class module(entPhysicalClass = 'module') which have a Processor. A processor module is defined as a physical entity that has a CPU, RAM and NVRAM so that it can independently - load a bootable image - save configuration. This module is the entry point for external applications like SNMP Manager, CLI, FTP etc. Line card is an interface card with at least a Processor and RAM. This might be referred to as Service Module in some cisco products. A configuration register is a 16 bit software register. The configuration register is mainly used to check for instructions on where to find the Cisco Operating System software. Some other functions of configuration register are: - To select a boot source and default boot filename. - To enable or disable the Break function. - To control broadcast addresses. - To set the console terminal baud rate. - To load operating software from Flash memory. - To allow us to manually boot the system using the boot command at the bootstrap program prompt. Booting is the process of initializing the hardware and starting the Operating System.
MODULE-IDENTITY    

ciscoEntityExtMIBObjects 1.3.6.1.4.1.9.9.195.1
OBJECT IDENTIFIER    

ceExtPhysicalProcessorTable 1.3.6.1.4.1.9.9.195.1.1
The ceExtPhysicalProcessorTable extends the ENTITY-MIB entPhysicalTable for modules (Non FRUs(Field Replacable Units) or FRUs).
OBJECT-TYPE    
  SEQUENCE OF  
    CeExtPhysicalProcessorEntry

ceExtPhysicalProcessorEntry 1.3.6.1.4.1.9.9.195.1.1.1
A ceExtPhysicalProcessorTable entry extends a corresponding entPhysicalTable entry of class module(entPhysicalClass = 'module'). A processor module or line card which has a processor will have an entry in this table. A processor module or line card having multiple processors and is a SMP(Symmetric multi processor) system will have only one entry corresponding to all the processors since the resources defined below are shared. A processor module or line card having multiple processors and is not an SMP system would register the processors as separate entities. Entries are created by the agent at the system power-up or module insertion. Entries are removed when the module is reset or removed.
OBJECT-TYPE    
  CeExtPhysicalProcessorEntry  

ceExtProcessorRam 1.3.6.1.4.1.9.9.195.1.1.1.1
Total number of bytes of RAM available on the Processor.
OBJECT-TYPE    
  Unsigned32  

ceExtNVRAMSize 1.3.6.1.4.1.9.9.195.1.1.1.2
Total number of bytes of NVRAM in the entity. A value of 0 for this object means the entity does not support NVRAM or NVRAM information is not available.
OBJECT-TYPE    
  Unsigned32  

ceExtNVRAMUsed 1.3.6.1.4.1.9.9.195.1.1.1.3
Number of bytes of NVRAM in use. This object is irrelevant if ceExtNVRAMSize is 0.
OBJECT-TYPE    
  Unsigned32  

ceExtProcessorRamOverflow 1.3.6.1.4.1.9.9.195.1.1.1.4
This object represents the upper 32-bit of ceExtProcessorRam. This object needs to be supported only if the available RAM bytes exceeds 32-bit, otherwise this object value would be set to 0.
OBJECT-TYPE    
  Unsigned32  

ceExtHCProcessorRam 1.3.6.1.4.1.9.9.195.1.1.1.5
This object represents the total number of bytes of RAM available on the Processor. This object is a 64-bit version of ceExtProcessorRam.
OBJECT-TYPE    
  Unsigned64  

ceExtConfigRegTable 1.3.6.1.4.1.9.9.195.1.2
The ceExtConfigRegTable extends the ENTITY-MIB entPhysicalTable.
OBJECT-TYPE    
  SEQUENCE OF  
    CeExtConfigRegEntry

ceExtConfigRegEntry 1.3.6.1.4.1.9.9.195.1.2.1
A ceExtConfigRegTable entry extends a corresponding entPhysicalTable entry of class module which has a configuration register. Entries are created by the agent at the system power-up or module insertion. Entries are removed when the module is reset or removed.
OBJECT-TYPE    
  CeExtConfigRegEntry  

ceExtConfigRegister 1.3.6.1.4.1.9.9.195.1.2.1.1
The value of configuration register with which the processor module booted.
OBJECT-TYPE    
  ConfigRegisterValue  

ceExtConfigRegNext 1.3.6.1.4.1.9.9.195.1.2.1.2
The value of configuration register in the processor module at next reboot. Just after the reboot this has the same value as ceExtConfigRegister.
OBJECT-TYPE    
  ConfigRegisterValue  

ceExtSysBootImageList 1.3.6.1.4.1.9.9.195.1.2.1.3
The list of system boot images which can be used for booting.
OBJECT-TYPE    
  BootImageList  

ceExtKickstartImageList 1.3.6.1.4.1.9.9.195.1.2.1.4
The list of system kickstart images which can be used for booting.
OBJECT-TYPE    
  BootImageList  

ceExtEntityLEDTable 1.3.6.1.4.1.9.9.195.1.3
A table containing information of LED on an entity.
OBJECT-TYPE    
  SEQUENCE OF  
    CeExtEntityLEDEntry

ceExtEntityLEDEntry 1.3.6.1.4.1.9.9.195.1.3.1
An entry (conceptual row) in the ceExtEntityLEDTable, containing information about an LED on an entity, identified by entPhysicalIndex.
OBJECT-TYPE    
  CeExtEntityLEDEntry  

ceExtEntityLEDType 1.3.6.1.4.1.9.9.195.1.3.1.1
The type of LED on this entity. 'status' - indicates the entity status. 'system' - indicates the overall system status. 'active' - the redundancy status of a module, for e.g. supervisor module. 'power' - indicates sufficient power availability for all modules. 'battery'- indicates the battery status.
OBJECT-TYPE    
  INTEGER status(1), system(2), active(3), power(4), battery(5)  

ceExtEntityLEDColor 1.3.6.1.4.1.9.9.195.1.3.1.2
The color of the LED.
OBJECT-TYPE    
  INTEGER off(1), green(2), amber(3), red(4)  

ceExtEntPhysicalTable 1.3.6.1.4.1.9.9.195.1.4
This table contains additional information about a particular physical entity. This table augments the 'entPhysicalTable' of the ENTITY-MIB.
OBJECT-TYPE    
  SEQUENCE OF  
    CeExtEntPhysicalEntry

ceExtEntPhysicalEntry 1.3.6.1.4.1.9.9.195.1.4.1
An entry (conceptual row) in the 'ceExtEntPhysicalTable', containing additional information about a physical entity, identified by 'entPhysicalIndex'.
OBJECT-TYPE    
  CeExtEntPhysicalEntry  

ceEntPhysicalSecondSerialNum 1.3.6.1.4.1.9.9.195.1.4.1.1
This object represents the vendor-specific second serial number string for the physical entity. The first serial number string of the physical entity is represented in the value of corresponding instance of the 'entPhysicalSerialNum' object. On the first instantiation of an physical entity, the value of this object is the correct vendor-assigned second serial number, if this information is available to the agent. If the second serial number is unknown or non-existent, then the value of this object will be a zero-length string instead. Note that implementations which can correctly identify the second serial numbers of all installed physical entities do not need to provide write access to this object. Agents which cannot provide non-volatile storage for the second serial number strings are not required to implement write access for this object. Not every physical component will have a serial number, or even need one. Physical entities for which the associated value of the entPhysicalIsFRU object is equal to 'false(2)' (e.g., the repeater ports within a repeater module), do not need their own unique serial number. An agent does not have to provide write access for such entities, and may return a zero-length string. If write access is implemented for an instance of 'ceEntPhysicalSecondSerialNum', and a value is written into the instance, the agent must retain the supplied value in the 'ceEntPhysicalSecondSerialNum' instance associated with the same physical entity for as long as that entity remains instantiated. This includes instantiations across all re- initializations/reboots of the network management system, including those which result in a change of the physical entity's entPhysicalIndex value.
OBJECT-TYPE    
  SnmpAdminString Size(0..32)  

ceExtNotificationControlObjects 1.3.6.1.4.1.9.9.195.1.5
OBJECT IDENTIFIER    

ceExtEntDoorNotifEnable 1.3.6.1.4.1.9.9.195.1.5.1
This object controls the generation of ceExtEntDoorCloseNotif and ceExtEntDoorOpenNotif notifications as follows: 'true(1)' - the generation of ceExtEntDoorCloseNotif and ceExtEntDoorOpenNotif notifications are enabled. 'false(2)' - the generation of ceExtEntDoorCloseNotif and ceExtEntDoorOpenNotif notifications are disabled.
OBJECT-TYPE    
  TruthValue  

ceExtEntBreakOutPortNotifEnable 1.3.6.1.4.1.9.9.195.1.5.2
This object controls the generation of ceExtBreakOutPortInserted and ceExtBreakOutPortRemoved as follows: 'true(1)' - the generation of ceExtBreakOutPortInserted and ceExtBreakOutPortRemoved notifications is enabled. 'false(2)' - the generation of ceExtBreakOutPortInserted and ceExtBreakOutPortRemoved notifications is disabled.
OBJECT-TYPE    
  TruthValue  

ceExtEntUsbModemNotifEnable 1.3.6.1.4.1.9.9.195.1.5.3
This object controls the generation of ceExtUSBModemPlugInNotif and ceExtUSBModemPlugOutNotif as follows: 'true(1)' - the generation of ceExtUSBModemPlugInNotif and ceExtUSBModemPlugOutNotif notifications is enabled. 'false(2)' - the generation of ceExtUSBModemPlugOutNotif and ceExtUSBModemPlugOutNotif notifications is disabled.
OBJECT-TYPE    
  TruthValue  

ceExtUSBModemTable 1.3.6.1.4.1.9.9.195.1.6
A table containing information of USB MODEMs on an entity.
OBJECT-TYPE    
  SEQUENCE OF  
    CeExtUSBModemEntry

ceExtUSBModemEntry 1.3.6.1.4.1.9.9.195.1.6.1
An entry (conceptual row) in the ceExtUSBModemTable, containing information about an USB MODEM on an entity, identified by entPhysicalIndex.
OBJECT-TYPE    
  CeExtUSBModemEntry  

ceExtUSBModemIMEI 1.3.6.1.4.1.9.9.195.1.6.1.1
The International Mobile Equipment Identifier (IMEI) of the USB-MODEM
OBJECT-TYPE    
  SnmpAdminString Size(0..64)  

ceExtUSBModemIMSI 1.3.6.1.4.1.9.9.195.1.6.1.2
The International Mobile Subscriber Identifier(IMSI) - for a GSM USB MODEM.
OBJECT-TYPE    
  SnmpAdminString Size(0..64)  

ceExtUSBModemServiceProvider 1.3.6.1.4.1.9.9.195.1.6.1.3
The Service Provider name for a USB MODEM.
OBJECT-TYPE    
  SnmpAdminString Size(0..64)  

ceExtUSBModemSignalStrength 1.3.6.1.4.1.9.9.195.1.6.1.4
The signal strength of the USB MODEM.
OBJECT-TYPE    
  SnmpAdminString Size(0..64)  

ceExtMIBNotificationPrefix 1.3.6.1.4.1.9.9.195.2
OBJECT IDENTIFIER    

ciscoEntityExtMIBNotifications 1.3.6.1.4.1.9.9.195.2.0
OBJECT IDENTIFIER    

ceExtEntDoorCloseNotif 1.3.6.1.4.1.9.9.195.2.0.1
A ceExtEntDoorCloseNotif is generated if the door of an entity has been closed.
NOTIFICATION-TYPE    

ceExtEntDoorOpenNotif 1.3.6.1.4.1.9.9.195.2.0.2
A ceExtEntDoorOpenNotif is generated if the door of an entity has been opened.
NOTIFICATION-TYPE    

ceExtBreakOutPortInserted 1.3.6.1.4.1.9.9.195.2.0.3
The ceExtBreakOutPortInserted notification indicates that a Breakout port was inserted. The varbind for this notification indicates the entPhysicalIndex of the inserted Breakout port, and the entPhysicalIndex of the BreakOut Port module that contains this port.
NOTIFICATION-TYPE    

ceExtBreakOutPortRemoved 1.3.6.1.4.1.9.9.195.2.0.4
The ceExtBreakOutPortRemoved notification indicates that a Breakout Port was removed. The varbind for this notification indicates the entPhysicalIndex of the removed Breakout port, and the entPhysicalIndex of the BreakOut Port module that contains this port.
NOTIFICATION-TYPE    

ceExtUSBModemPlugInNotif 1.3.6.1.4.1.9.9.195.2.0.5
The ceExtUSBModemPlugInNotif notification indicates that a USB MODEM was inserted. The varbind for this notification indicates the entPhysicalDescr of the inserted USB MODEM, and the entPhysicalIndex of the USB MODEM's container.
NOTIFICATION-TYPE    

ceExtUSBModemPlugOutNotif 1.3.6.1.4.1.9.9.195.2.0.6
The ceExtUSBModemPlugOutNotif notification indicates that a USB MODEM was removed. The varbind for this notification indicates the entPhysicalDescr of the removed USB MODEM, and the entPhysicalIndex of the USB MODEM's container.
NOTIFICATION-TYPE    

ciscoEntityExtMIBConformance 1.3.6.1.4.1.9.9.195.3
OBJECT IDENTIFIER    

ciscoEntityExtMIBCompliances 1.3.6.1.4.1.9.9.195.3.1
OBJECT IDENTIFIER    

ciscoEntityExtMIBGroups 1.3.6.1.4.1.9.9.195.3.2
OBJECT IDENTIFIER    

ciscoEntityExtMIBCompliance 1.3.6.1.4.1.9.9.195.3.1.1
This group is an optional group containing an object which provides information about the system boot images.
MODULE-COMPLIANCE    

ciscoEntityExtMIBComplianceRev1 1.3.6.1.4.1.9.9.195.3.1.2
This group is an optional group containing an object which provides information about the system boot images.
MODULE-COMPLIANCE    

ciscoEntityExtMIBComplianceRev2 1.3.6.1.4.1.9.9.195.3.1.3
This group is an optional group containing an object which provides additional information about the physical entity.
MODULE-COMPLIANCE    

ciscoEntityExtMIBComplianceRev3 1.3.6.1.4.1.9.9.195.3.1.4
This group is an optional group for the physical entities which support 32-bit operating system.
MODULE-COMPLIANCE    

ciscoEntityExtMIBComplianceRev4 1.3.6.1.4.1.9.9.195.3.1.5
Write access is not required.
MODULE-COMPLIANCE    

ciscoEntityExtMIBComplianceRev5 1.3.6.1.4.1.9.9.195.3.1.6
Write access is not required.
MODULE-COMPLIANCE    

ciscoEntityExtMIBComplianceRev6 1.3.6.1.4.1.9.9.195.3.1.7
Write access is not required.
MODULE-COMPLIANCE    

ceExtPhysicalProcessorGroup 1.3.6.1.4.1.9.9.195.3.2.1
The collection of objects which give information about the Processor RAM and NVRAM.
OBJECT-GROUP    

ciscoEntityExtConfigRegGroup 1.3.6.1.4.1.9.9.195.3.2.2
The collection of objects which give information about configuration register. Implementation of this group is optional.
OBJECT-GROUP    

ceExtSysBootImageListGroup 1.3.6.1.4.1.9.9.195.3.2.3
A group containing an object providing information about the system boot images. Implementation of this group is optional.
OBJECT-GROUP    

ciscoEntityExtLEDGroup 1.3.6.1.4.1.9.9.195.3.2.4
A collection of objects for giving led information.
OBJECT-GROUP    

ceExtSysBootImageListGroupRev1 1.3.6.1.4.1.9.9.195.3.2.5
A group containing an object providing information about the system boot images. Implementation of this group is optional.
OBJECT-GROUP    

ciscoExtEntityPhysicalGroup 1.3.6.1.4.1.9.9.195.3.2.6
The collection of objects for providing additional information about the physical entity. Implementation of this group is optional.
OBJECT-GROUP    

ceExtPhyProcessorOverflowGroup 1.3.6.1.4.1.9.9.195.3.2.7
The collection of Overflow (upper 32-bit) objects which provides information about physical processor, when the entity runs on 64-bit Operating System (OS). This group is optional for the entities which run on 32-bit OS.
OBJECT-GROUP    

ceExtPhyProcessorHCGroup 1.3.6.1.4.1.9.9.195.3.2.8
The collection of High Capacity (HC) objects which provides information about physical processor, when the entity runs on 64-bit Operating System (OS). This group is optional for the entities which run on 32-bit OS.
OBJECT-GROUP    

ceExtEntDoorNotifGroup 1.3.6.1.4.1.9.9.195.3.2.9
A collection of objects providing the notification information for door entitites.
NOTIFICATION-GROUP    

ceExtEntDoorNotifControlGroup 1.3.6.1.4.1.9.9.195.3.2.10
A collection of objects providing control for entity door notifications.
OBJECT-GROUP    

ceExtBreakOutPortNotifGroup 1.3.6.1.4.1.9.9.195.3.2.11
A collection of objects providing the notification information for supporting Breakout port feature.
NOTIFICATION-GROUP    

ceExtBreakOutPortNotifControlGroup 1.3.6.1.4.1.9.9.195.3.2.12
A collection of objects providing control for Breakout Port notifications.
OBJECT-GROUP    

ceExtUSBModemGroup 1.3.6.1.4.1.9.9.195.3.2.13
A collection of objects for giving USB MODEM config information.
OBJECT-GROUP    

ceExtUsbModemNotificationsGroup 1.3.6.1.4.1.9.9.195.3.2.14
A collection of notifications for USB MODEM removal and insertion.
NOTIFICATION-GROUP    

ceExtUsbModemNotifControlGroup 1.3.6.1.4.1.9.9.195.3.2.15
A collection of objects providing control for USB MODEM notifications.
OBJECT-GROUP