CISCO-CAT6K-CROSSBAR-MIB
File:
CISCO-CAT6K-CROSSBAR-MIB.mib (108945 bytes)
Imported modules
Imported symbols
Defined Types
ChannelStatus |
|
Status of the Channel. |
TEXTUAL-CONVENTION |
|
|
|
|
INTEGER |
ok(1), syncError(2), heartbeatError(3), crcError(4), bufferError(5), timeoutError(6), unused(7) |
|
Cc6kxbarLcdBannerEntry |
|
SEQUENCE |
|
|
|
|
cc6kxbarLcdBannerIndex |
Unsigned32 |
|
|
cc6kxbarLcdBannerBanner |
DisplayString |
|
|
cc6kxbarLcdBannerMaxSize |
Unsigned32 |
|
Cc6kxbarModuleModeEntry |
|
SEQUENCE |
|
|
|
|
cc6kxbarModuleModeModule |
ModuleSlotNumber |
|
|
cc6kxbarModuleModeSwitchingMode |
INTEGER |
|
Cc6kxbarModuleChannelEntry |
|
SEQUENCE |
|
|
|
|
cc6kxbarModuleChannelModule |
ModuleSlotNumber |
|
|
cc6kxbarModuleChannelChannel |
FabricChannelNumber |
|
|
cc6kxbarModuleChannelModStatus |
ChannelStatus |
|
|
cc6kxbarModuleChannelFabStatus |
ChannelStatus |
|
|
cc6kxbarModuleChannelSpeed |
Gauge32 |
|
Cc6kxbarStatisticsEntry |
|
SEQUENCE |
|
|
|
|
cc6kxbarStatisticsModule |
ModuleSlotNumber |
|
|
cc6kxbarStatisticsChannel |
FabricChannelNumber |
|
|
cc6kxbarStatisticsInErrors |
Counter32 |
|
|
cc6kxbarStatisticsOutErrors |
Counter32 |
|
|
cc6kxbarStatisticsOutDropped |
Counter32 |
|
|
cc6kxbarStatisticsInUtil |
Percent |
|
|
cc6kxbarStatisticsOutUtil |
Percent |
|
|
cc6kxbarStatisticsPeakInUtil |
Percent |
|
|
cc6kxbarStatisticsPeakTmInUtil |
DateAndTime |
|
|
cc6kxbarStatisticsPeakOutUtil |
Percent |
|
|
cc6kxbarStatisticsPeakTmOutUtil |
DateAndTime |
|
|
cc6kxbarStatisticsLbusDrops |
Counter32 |
|
Cc6kxbarErrorEntry |
|
SEQUENCE |
|
|
|
|
cc6kxbarErrorModule |
ModuleSlotNumber |
|
|
cc6kxbarErrorChannel |
FabricChannelNumber |
|
|
cc6kxbarErrorModuleCrc |
Gauge32 |
|
|
cc6kxbarErrorModuleHbeat |
Gauge32 |
|
|
cc6kxbarErrorModuleSync |
Gauge32 |
|
|
cc6kxbarErrorModuleDDRSync |
Gauge32 |
|
|
cc6kxbarErrorChannelSync |
Gauge32 |
|
|
cc6kxbarErrorChannelBuffer |
Gauge32 |
|
|
cc6kxbarErrorChannelTimeout |
Gauge32 |
|
Cc6kxbarIntBusCRCErrEntry |
|
SEQUENCE |
|
|
|
|
cc6kxbarIntBusCRCErrExcdStatus |
TruthValue |
|
|
cc6kxbarIntBusCRCErrExcdCount |
Unsigned32 |
|
Cc6kxbarSysCapSwitchResEntry |
|
SEQUENCE |
|
|
|
|
cc6kxbarSysCapSwitchResSeries |
INTEGER |
|
|
cc6kxbarSysCapSwitchResCefMode |
INTEGER |
|
Cc6kxbarTMChUtilEntry |
|
SEQUENCE |
|
|
|
|
cc6kxbarTMChUtilModule |
ModuleSlotNumber |
|
|
cc6kxbarTMChUtilChannel |
FabricChannelNumber |
|
|
cc6kxbarTMChUtilDirection |
INTEGER |
|
|
cc6kxbarTMChUtilEnable |
TruthValue |
|
|
cc6kxbarTMChUtilInterval |
Unsigned32 |
|
|
cc6kxbarTMChUtilThreshold |
Percent |
|
|
cc6kxbarTMChUtilLogCount |
Counter32 |
|
|
cc6kxbarTMChUtilLastLogTime |
DateAndTime |
|
Defined Values
ciscoCat6kCrossbarMIB |
1.3.6.1.4.1.9.9.217 |
The Catalyst 6000 Crossbar MIB provides instrumentation for
configuration and operation of the crossbar switching fabric
module, and additional functionalities for switching bus
and internal bus, etc. |
MODULE-IDENTITY |
|
|
|
cc6kxbarFallbackMode |
1.3.6.1.4.1.9.9.217.1.1.1 |
cc6kxbarFallbackMode controls system fallback to bus-mode
after loss of switching fabric module.
'true' - When the last fabric card is removed
system will adjust the supervisor and
line cards switching mode automatically without
resetting the system. With this feature enabled,
the switch might lose traffic while it's
changing the switching mode.
'false' - All the ports in the system will be
disabled when the last fabric card is removed. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
TruthValue |
|
|
cc6kxbarBusOnlyModeAllowed |
1.3.6.1.4.1.9.9.217.1.1.2 |
Indicates whether bus mode is administratively enabled on
the device or not. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
TruthValue |
|
|
cc6kxbarTruncatedModeAllowed |
1.3.6.1.4.1.9.9.217.1.1.3 |
Indicates whether truncated mode is
administratively enabled on the device or not. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
TruthValue |
|
|
cc6kxbarMinFabricPresent |
1.3.6.1.4.1.9.9.217.1.1.4 |
This object indicates the minimum number
of switching fabric capable modules to be present in the
system, for any switching fabric capable module to be in
'crossbarmode' indicated by cc6kxbarModuleModeSwitchingMode,
when cc6kxbarTruncatedModeOper is 'false'. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
Unsigned32 |
|
|
cc6kxbarLcdBannerEntry |
1.3.6.1.4.1.9.9.217.1.1.5.1 |
An entry in cc6kxbarLcdBannerTable.
Entries are created by the agent based on the
size of the lcd banner. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
Cc6kxbarLcdBannerEntry |
|
|
cc6kxbarLcdBannerIndex |
1.3.6.1.4.1.9.9.217.1.1.5.1.1 |
Object which specifies a unique entry in the
table. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
Unsigned32 |
|
|
cc6kxbarLcdBannerBanner |
1.3.6.1.4.1.9.9.217.1.1.5.1.2 |
Message that would be displayed on the fabric card LCD.
The size of cc6kxbarLcdBannerBanner should be less than
or equal to the cc6kxbarLcdBannerMaxSize value. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
cc6kxbarLcdBannerMaxSize |
1.3.6.1.4.1.9.9.217.1.1.5.1.3 |
Maximum size of the associated cc6kxbarLcdBannerBanner
object. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Unsigned32 |
|
|
cc6kxbarTruncatedModeOper |
1.3.6.1.4.1.9.9.217.1.1.6 |
Indicates if the truncated mode is
operationally enabled on the device or not.
'true' - With the fabric module present in the system,
cc6kxbarModuleModeSwitchingMode will be
'crossbarmode' for all the fabric capable
modules.
'false'- With the cc6kxbarMinFabricPresent fabric capable
modules and the fabric module present in the system,
cc6kxbarModuleModeSwitchingMode
will be 'crossbarmode' for fabric capable modules. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
TruthValue |
|
|
cc6kxbarDcefOnlyModeAllowed |
1.3.6.1.4.1.9.9.217.1.1.7 |
Indicates whether the dcef mode is enabled on the standby
supervisor or not.
'true' - Setting cc6kxbarDcefOnlyModeAllowed to 'true'
makes the cc6kxbarModuleModeSwitchingMode of
all the active modules to 'dcefmode'.
With the active fabric module present in the system,
with the switch being in stateful switchover mode,
with all the cards that has no distributed Cisco
Express forwarding switching support being
powered down and on some platforms with standby
supervisor ports being shutdown, changing
cc6kxbarDcefOnlyModeAllowed to 'true' will make the
standby supervisor module reloaded and booted up
as distributed forwarding module.
'false'- Setting cc6kxbarDcefOnlyModeAllowed to 'false'
makes the cc6kxbarModuleModeSwitchingMode of the
standby supervisor module to the default value.
Changing cc6kxbarDcefOnlyModeAllowed to 'false'
will make the standby supervisor reloaded and booted
up with the default cc6kxbarModuleModeSwitchingMode. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
TruthValue |
|
|
cc6kxbarForceBusMode |
1.3.6.1.4.1.9.9.217.1.1.8 |
Indicates whether some affected modules are forced to be in
'busmode' or not.
'true' - Setting cc6kxbarForceBusMode to 'true' makes the
cc6kxbarModuleModeSwitchingMode of all
the affected modules to 'busmode'. Changing the
cc6kxbarForceBusMode to 'true' will make all the
affected modules reloaded and booted up as
non fabric capable modules.
'false'- Setting cc6kxbarForceBusMode to 'false' makes the
cc6kxbarModuleModeSwitchingMode of all the affected
modules to the default value. Changing
cc6kxbarForceBusMode to 'false' will make all the
affected modules reloaded and booted up with the
default cc6kxbarModuleModeSwitchingMode. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
TruthValue |
|
|
cc6kxbarBusOnlyModeOper |
1.3.6.1.4.1.9.9.217.1.1.9 |
Indicates if the bus mode is operationally enabled on the
device or not.
'true' - Modules are allowed to run in 'busmode'.
'false' - None of the modules are allowed to run in 'busmode'
i.e., All the non-fabric capable modules will
be powered off. Absence of fabric module results
in all the fabric capable modules being powered
off. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
TruthValue |
|
|
cc6kxbarFabricActiveSlot |
1.3.6.1.4.1.9.9.217.1.2.1 |
cc6kxbarFabricActiveSlot indicates the slot number of the
active switching fabric module. A value of zero indicates
that the active switching fabric module is either powered
down or not present in the chassis. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
ModuleSlotNumber |
|
|
cc6kxbarFabricBackupSlot |
1.3.6.1.4.1.9.9.217.1.2.2 |
cc6kxbarFabricBackupSlot indicates the slot number of the
backup switching fabric module. A value of zero indicates
that the backup switching fabric module is either powered
down or not present in the chassis. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
ModuleSlotNumber |
|
|
cc6kxbarModuleModeEntry |
1.3.6.1.4.1.9.9.217.1.2.3.1 |
An entry in cc6kxbarModuleModeTable. The agent creates
an entry when a non switching fabric module
is inserted in the chassis.
The agent destroys an entry when a non switching fabric
module is power down or reset or removed from the chassis. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
Cc6kxbarModuleModeEntry |
|
|
cc6kxbarModuleModeSwitchingMode |
1.3.6.1.4.1.9.9.217.1.2.3.1.2 |
cc6kxbarModuleModeSwitchingMode indicates switching mode
of the cc6kxbarModuleModeModule.
'busmode' - Modules in this mode don't use fabric.
Backplane is used for both lookup and data
forwarding.
'crossbarmode' - Modules in this mode use backplane
for forwarding decision and fabric for data
forwarding
'dcefmode' - Modules in this mode use fabric for data
forwarding and local forwarding is enabled. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
busmode(1), crossbarmode(2), dcefmode(3) |
|
cc6kxbarModuleChannelTable |
1.3.6.1.4.1.9.9.217.1.2.4 |
cc6kxbarModuleChannelTable shows the operational status
of fabric channels. This table will be instantiated only when
cc6kxbarFabricActiveSlot has a valid value other than zero. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
SEQUENCE OF |
|
|
|
|
Cc6kxbarModuleChannelEntry |
|
cc6kxbarModuleChannelEntry |
1.3.6.1.4.1.9.9.217.1.2.4.1 |
An entry in cc6kxbarModuleChannelTable. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
Cc6kxbarModuleChannelEntry |
|
|
cc6kxbarModuleChannelSpeed |
1.3.6.1.4.1.9.9.217.1.2.4.1.5 |
The speed in mega bits per second of the
cc6kxbarModuleChannelChannel for cc6kxbarModuleChannelModule. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Gauge32 |
|
|
cc6kxbarStatisticsTable |
1.3.6.1.4.1.9.9.217.1.3.1 |
cc6kxbarStatisticsTable gives the
fabric channel counters and utilization
information. This table will be instantiated when
cc6kxbarFabricActiveSlot has a valid value other than
zero. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
SEQUENCE OF |
|
|
|
|
Cc6kxbarStatisticsEntry |
|
cc6kxbarStatisticsEntry |
1.3.6.1.4.1.9.9.217.1.3.1.1 |
An entry in cc6kxbarStatisticsTable. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
Cc6kxbarStatisticsEntry |
|
|
cc6kxbarStatisticsInErrors |
1.3.6.1.4.1.9.9.217.1.3.1.1.3 |
The total number of error packets received on
cc6kxbarStatisticsChannel for cc6kxbarStatisticsModule
since this entry was last initialized. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Counter32 |
|
|
cc6kxbarStatisticsOutErrors |
1.3.6.1.4.1.9.9.217.1.3.1.1.4 |
The total number of error packets transmitted on
cc6kxbarStatisticsModule through the
cc6kxbarStatisticsChannel since this entry was
last initialized. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Counter32 |
|
|
cc6kxbarStatisticsOutDropped |
1.3.6.1.4.1.9.9.217.1.3.1.1.5 |
The total number of dropped packets transmitted on the
cc6kxbarStatisticsChannel for cc6kxbarStatisticsModule
since this entry was last initialized. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Counter32 |
|
|
cc6kxbarStatisticsInUtil |
1.3.6.1.4.1.9.9.217.1.3.1.1.6 |
Input utilization of the cc6kxbarStatisticsChannel for
cc6kxbarStatisticsModule. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Percent |
|
|
cc6kxbarStatisticsOutUtil |
1.3.6.1.4.1.9.9.217.1.3.1.1.7 |
Output utilization of the cc6kxbarStatisticsChannel for
cc6kxbarStatisticsModule. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Percent |
|
|
cc6kxbarStatisticsPeakInUtil |
1.3.6.1.4.1.9.9.217.1.3.1.1.8 |
Indicates the peak value of cc6kxbarStatisticsInUtil of the
cc6kxbarStatisticsChannel for cc6kxbarStatisticsModule. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Percent |
|
|
cc6kxbarStatisticsPeakTmInUtil |
1.3.6.1.4.1.9.9.217.1.3.1.1.9 |
Indicates the time of most recent change in the corresponding
instance value of cc6kxbarStatisticsPeakInUtil.
This object contains value 0x0000010100000000 when the
corresponding instance value of cc6kxbarStatisticsPeakInUtil
is '0'. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DateAndTime |
|
|
cc6kxbarStatisticsPeakOutUtil |
1.3.6.1.4.1.9.9.217.1.3.1.1.10 |
Indicates the peak value of cc6kxbarStatisticsOutUtil of the
cc6kxbarStatisticsChannel for cc6kxbarStatisticsModule. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Percent |
|
|
cc6kxbarStatisticsPeakTmOutUtil |
1.3.6.1.4.1.9.9.217.1.3.1.1.11 |
Indicates the time of most recent change in the corresponding
instance value of cc6kxbarStatisticsPeakOutUtil.
This object contains value 0x0000010100000000 when the
corresponding instance value of cc6kxbarStatisticsPeakOutUtil
is '0'. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DateAndTime |
|
|
cc6kxbarStatisticsLbusDrops |
1.3.6.1.4.1.9.9.217.1.3.1.1.12 |
This object indicates the number of packets that have been
deterministically dropped due to the threshold on the local
bus FIFO, errors and exception conditions. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Counter32 |
|
|
cc6kxbarErrorTable |
1.3.6.1.4.1.9.9.217.1.3.2 |
cc6kxbarErrorTable provides the fabric channel error
information. This table will be instantiated only when
cc6kxbarFabricActiveSlot has a valid value other than zero. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
SEQUENCE OF |
|
|
|
|
Cc6kxbarErrorEntry |
|
cc6kxbarErrorEntry |
1.3.6.1.4.1.9.9.217.1.3.2.1 |
An entry in cc6kxbarErrorTable for a specific fabric channel
on a specific module. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
Cc6kxbarErrorEntry |
|
|
cc6kxbarErrorModuleCrc |
1.3.6.1.4.1.9.9.217.1.3.2.1.3 |
Indicates the total number of CRC error packets for the
cc6kxbarErrorChannel of the cc6kxbarErrorModule. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Gauge32 |
|
|
cc6kxbarErrorModuleHbeat |
1.3.6.1.4.1.9.9.217.1.3.2.1.4 |
Indicates the total number of heartbeat misses detected
for the cc6kxbarErrorChannel of the cc6kxbarErrorModule. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Gauge32 |
|
|
cc6kxbarErrorModuleSync |
1.3.6.1.4.1.9.9.217.1.3.2.1.5 |
Indicates the total number of times cc6kxbarErrorModule could
not sync to the active switching fabric module. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Gauge32 |
|
|
cc6kxbarErrorModuleDDRSync |
1.3.6.1.4.1.9.9.217.1.3.2.1.6 |
Indicates the total number of DDR(Double Data Rate) channel
sync errors for the cc6kxbarErrorChannel of the
cc6kxbarErrorModule. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Gauge32 |
|
|
cc6kxbarErrorChannelSync |
1.3.6.1.4.1.9.9.217.1.3.2.1.7 |
Indicates the total number of sync errors received at
cc6kxbarErrorChannel. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Gauge32 |
|
|
cc6kxbarErrorChannelBuffer |
1.3.6.1.4.1.9.9.217.1.3.2.1.8 |
Indicates the total number of times the memory buffer for
cc6kxbarErrorChannel of the cc6kxbarErrorModule is full. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Gauge32 |
|
|
cc6kxbarErrorChannelTimeout |
1.3.6.1.4.1.9.9.217.1.3.2.1.9 |
Indicates the total number of timeouts for input from
the cc6kxbarErrorChannel of the cc6kxbarErrorModule. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Gauge32 |
|
|
cc6kxbarSwBusSwitchingStatus |
1.3.6.1.4.1.9.9.217.1.4.1 |
Indicates the current switching status of the
switching bus on the system.
normal -- the switching bus is under normal
packet switching operation.
stalled -- the switching bus has stopped packet
switching but is still attached to
the system, i.e., the switching bus
is stalled.
isolated -- the switching bus has stopped packet
switching and is detached from
the system, i.e., the switching bus
is isolated.
The object is only instantiated on systems which
support switching bus switching detection feature. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
normal(1), stalled(2), isolated(3) |
|
cc6kxbarSwBusFailureDuration |
1.3.6.1.4.1.9.9.217.1.4.2 |
Indicates the failure duration of the switching
bus since the switching bus has transitioned
out of the normal(1) state as monitored by
cc6kxbarSwBusSwitchingStatus. If the object
value of cc6kxbarSwBusSwitchingStatus is
normal(1), then the object value of
cc6kxbarSwBusFailureDuration should be zero.
The object is only instantiated on systems which
support switching bus switching detection feature. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Unsigned32 |
|
|
cc6kxbarSwBusNotifEnable |
1.3.6.1.4.1.9.9.217.1.4.3 |
Indicates whether or not the notification
cc6kxbarSwBusStatusChangeNotif should be generated
when there is change in the switching status of the
switching bus as monitored by
cc6kxbarSwBusSwitchingStatus.
The object is only instantiated on systems which
support switching bus switching detection feature. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
TruthValue |
|
|
cc6kxbarSwBusUtilization |
1.3.6.1.4.1.9.9.217.1.4.4 |
Indicates the percentage of bandwidth utilization
of the switching bus. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Percent |
|
|
cc6kxbarSwBusPeakUtilization |
1.3.6.1.4.1.9.9.217.1.4.5 |
Indicates the peak percentage value of bandwidth
utilization of the switching bus since the system
started. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Percent |
|
|
cc6kxbarSwBusPeakTimeUtil |
1.3.6.1.4.1.9.9.217.1.4.6 |
Indicates the time at which the peak percentage value
of bandwidth utilization of the switching bus value
occurred. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DateAndTime |
|
|
cc6kxbarIntBusNotifEnable |
1.3.6.1.4.1.9.9.217.1.5.1 |
Indicates whether the generation of a specified
notification for internal bus is enabled or not.
If a bit corresponding to a notification is set to
1, then that notification can be generated.
intBusCRCErrExcd -- the cc6kxbarIntBusCRCErrExcdNotif
notification.
intBusCRCErrRcvrd -- the cc6kxbarIntBusCRCErrRcvrdNotif
notification. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
BITS |
intBusCRCErrExcd(0), intBusCRCErrRcvrd(1) |
|
cc6kxbarIntBusCRCErrEntry |
1.3.6.1.4.1.9.9.217.1.5.2.1 |
An entry containing internal bus CRC error information
on a physical entity (such as a module). |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
Cc6kxbarIntBusCRCErrEntry |
|
|
cc6kxbarIntBusCRCErrExcdStatus |
1.3.6.1.4.1.9.9.217.1.5.2.1.1 |
Indicates whether the internal bus CRC error
on a physical entity is currently exceeding the fatal
threshold or not. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
TruthValue |
|
|
cc6kxbarIntBusCRCErrExcdCount |
1.3.6.1.4.1.9.9.217.1.5.2.1.2 |
Indicates the number of times the internal bus CRC
error on a physical entity has exceeded the fatal
threshold. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Unsigned32 |
|
|
cc6kxbarFlowCtrlNotifEnable |
1.3.6.1.4.1.9.9.217.1.6.1 |
Specifies whether the generation of a specified
notification for flow control feature is enabled or
not. If a bit corresponding to a notification is set
to one, then that notification can be generated.
busThreshExcd -- the cc6kxbarFlowCtrlBusThrExcdNotif
notification. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
BITS |
busThreshExcd(0) |
|
cc6kxbarFlowCtrlBusFIFOThrMode |
1.3.6.1.4.1.9.9.217.1.6.2 |
Specifies the mode configuration of the system bus
flow control FIFO threshold.
off -- the flow control FIFO threshold is set to the
original value defined by the system.
on -- the flow control FIFO threshold is set to the
lower value defined by the system.
auto -- the system starts monitoring the system bus
flow control FIFO threshold and will change the
flow control FIFO threshold from the original
value to the lower value when the system detects
the first occurrence of the threshold exceeding
on a physical entity (such as a module) over
the system allowed limit. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
off(1), on(2), auto(3) |
|
cc6kxbarFlowCtrlBusFIFOThrValue |
1.3.6.1.4.1.9.9.217.1.6.3 |
Indicates the current value of the system bus flow
control FIFO threshold, whether it is the original
value or the lower value. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
original(1), lower(2) |
|
cc6kxbarFlowCtrlBusFIFOTransTime |
1.3.6.1.4.1.9.9.217.1.6.4 |
Indicates the value of sysUpTime at the time
that the system bus flow control FIFO threshold
is transitioned to lower value when the object value
of cc6kxbarFlowCtrlBusFIFOThrValue is 'lower'. This
object will take on the value of zero when the object
value of cc6kxbarFlowCtrlBusFIFOThrValue is
'original'. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
TimeStamp |
|
|
cc6kxbarSysCapPfcOperMode |
1.3.6.1.4.1.9.9.217.1.7.1 |
Indicates the operating mode of the policy feature
card (PFC).
unknown -- unknown.
pfc3a -- Policy feature card 3A.
pfc3b -- Policy feature card 3B.
pfc3bxl -- Policy feature card 3B XL.
pfc3cst1 -- Policy feature card 3C ST1.
pfc3cxlst1 -- Policy feature card 3C XL ST1.
pfc3c -- Policy feature card 3C.
pfc3cxl -- Policy feature card 3C XL.
pfc4 -- Policy feature card 4.
pfc4xl -- Policy feature card 4 XL.
pfc4xxl -- Policy feature card 4 XXL.
pfc4lite -- Policy feature card 4 Lite. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
unknown(1), pfc3a(2), pfc3b(3), pfc3bxl(4), pfc3cst1(5), pfc3cxlst1(6), pfc3c(7), pfc3cxl(8), pfc4(9), pfc4xl(10), pfc4xxl(11), pfc4lite(12) |
|
cc6kxbarSysCapSwitchResTable |
1.3.6.1.4.1.9.9.217.1.7.2 |
A cc6kxbarSysCapSwitchResTable entry lists
the capacity information of the switching
resources for ENTITY-MIB entPhysicalTable entries
of manageable components with type entPhysicalClass
module(9). |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
SEQUENCE OF |
|
|
|
|
Cc6kxbarSysCapSwitchResEntry |
|
cc6kxbarSysCapSwitchResEntry |
1.3.6.1.4.1.9.9.217.1.7.2.1 |
A cc6kxbarSysCapSwitchResEntry entry lists
the capacity information of the switching
resources for ENTITY-MIB entPhysicalTable entries
of manageable components with type entPhysicalClass
module(9).
Entries are created by the agent at the system power-up
or module insertion.
Entries are deleted by the agent upon module removal. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
Cc6kxbarSysCapSwitchResEntry |
|
|
cc6kxbarSysCapSwitchResSeries |
1.3.6.1.4.1.9.9.217.1.7.2.1.1 |
Indicates the module series for traffic forwarding options.
unknown -- unknown.
supervisor -- supervisor module.
classic -- classic module.
fabric -- fabric module.
dcef720 -- dCEF720 module.
cef720 -- CEF720 module.
dcef256 -- dCEF256 module.
cef256 -- CEF256 module. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
unknown(1), supervisor(2), classic(3), fabric(4), dcef720(5), cef720(6), dcef256(7), cef256(8) |
|
cc6kxbarSysCapSwitchResCefMode |
1.3.6.1.4.1.9.9.217.1.7.2.1.2 |
Indicates the Cisco Express Forwarding (CEF) mode of
the module.
notApplicable -- not applicable for this module.
dcef -- distributed CEF.
cef -- CEF. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
notApplicable(1), dcef(2), cef(3) |
|
cc6kxbarErrRcvryThreshLink |
1.3.6.1.4.1.9.9.217.1.8.1 |
Specifies the threshold on fabric link errors occurring
in a channel for the fabric error recovery feature. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
Unsigned32 |
1..4294967295 |
|
cc6kxbarErrRcvryThreshPersLink |
1.3.6.1.4.1.9.9.217.1.8.2 |
Specifies the threshold on persistent fabric link errors
occurring in a channel for the fabric error recovery feature. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
Unsigned32 |
1..4294967295 |
|
cc6kxbarErrRcvrySwitchoverEnable |
1.3.6.1.4.1.9.9.217.1.8.3 |
Specifies whether the switchover to the standby fabric module
is enabled or not on the detection of excessive fabric link
errors occurring in a channel for the fabric error recovery
feature. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
TruthValue |
|
|
cc6kxbarErrRcvryPersLinkResync |
1.3.6.1.4.1.9.9.217.1.8.4 |
Specifies whether the system will resync the channel or not
on the detection of excessive persistent fabric link errors
in a channel for the fabric error recovery feature. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
TruthValue |
|
|
cc6kxbarErrRcvryChResyncCount |
1.3.6.1.4.1.9.9.217.1.8.5 |
Specifies the consecutive number of times of
channel resync within the time interval as specified
by cc6kxbarErrRcvryChResyncInterval, over which
the channel resync is considered as failure
for the fabric error recovery feature. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
Unsigned32 |
1..4294967295 |
|
cc6kxbarErrRcvryChResyncInterval |
1.3.6.1.4.1.9.9.217.1.8.6 |
Specifies the time interval for the consecutive
counting of channel resync for the fabric error
recovery feature. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
Unsigned32 |
1..4294967295 |
|
cc6kxbarTMSwBusUtilEnable |
1.3.6.1.4.1.9.9.217.1.9.1.1 |
Specifies whether the traffic monitor feature is
enabled on the switching bus or not. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
TruthValue |
|
|
cc6kxbarTMSwBusUtilInterval |
1.3.6.1.4.1.9.9.217.1.9.1.2 |
Specifies the interval at the end of which
the switching bus traffic utilization is compared
against cc6kxbarTMSwBusUtilThreshold. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
Unsigned32 |
1..4294967295 |
|
cc6kxbarTMSwBusUtilThreshold |
1.3.6.1.4.1.9.9.217.1.9.1.3 |
Specifies the threshold of the switching bus
traffic utilization. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
Percent |
|
|
cc6kxbarTMSwBusUtilLogCount |
1.3.6.1.4.1.9.9.217.1.9.1.4 |
Indicates the number of times the following
events are logged for the switching bus:
1. the switching bus traffic utilization has
risen above the configured threshold (as
specified by cc6kxbarTMSwBusUtilThreshold),
or has kept staying above the configured
threshold at a logging interval (as specified
by cc6kxbarTMSwBusUtilLogInterval).
2. the switching bus traffic utilization
has fallen below the configured threshold. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Counter32 |
|
|
cc6kxbarTMSwBusUtilLastLogTime |
1.3.6.1.4.1.9.9.217.1.9.1.5 |
Indicates the last logging time of the
events as counted in cc6kxbarTMSwBusUtilLogCount.
This object will contain 0-1-1,00:00:00.0 when
the value of cc6kxbarTMSwBusUtilLogCount is zero. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DateAndTime |
|
|
cc6kxbarTMSwBusUtilLogInterval |
1.3.6.1.4.1.9.9.217.1.9.1.6 |
Specifies the logging interval if the switching
bus traffic utilization keeps staying above the
cc6kxbarTMSwBusUtilThreshold. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
Unsigned32 |
1..4294967295 |
|
cc6kxbarTMSwBusUtilUtilization |
1.3.6.1.4.1.9.9.217.1.9.1.7 |
The switching bus traffic utilization included
in the notification currently being sent. |
Status: current |
Access: accessible-for-notify |
OBJECT-TYPE |
|
|
|
|
Percent |
|
|
cc6kxbarTMSwBusUtilNotifEnable |
1.3.6.1.4.1.9.9.217.1.9.1.8 |
Specifies whether the generation of
c6kxbarTMSwBusUtilAboveNotif and
c6kxbarTMSwBusUtilBelowNotif notifications
is enabled or not.
When this object is 'true', the generation of
cc6kxbarTMSwBusUtilAboveNotif and
c6kxbarTMSwBusUtilBelowNotif notifications is
enabled. When this object is 'false', the
generation of cc6kxbarTMSwBusUtilAboveNotif and
c6kxbarTMSwBusUtilBelowNotif notifications
is disabled. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
TruthValue |
|
|
cc6kxbarTMChUtilTable |
1.3.6.1.4.1.9.9.217.1.9.2.1 |
cc6kxbarTrafficMntrChUtilTable provides the
information on the traffic utilization of each
fabric channel associated with each module slot
for a given traffic direction in the chassis. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
SEQUENCE OF |
|
|
|
|
Cc6kxbarTMChUtilEntry |
|
cc6kxbarTMChUtilEntry |
1.3.6.1.4.1.9.9.217.1.9.2.1.1 |
An entry in cc6kxbarTMChUtilTable. Each traffic
direction for each fabric channel associated with
each module slot in the chassis will have an
entry in this table. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
Cc6kxbarTMChUtilEntry |
|
|
cc6kxbarTMChUtilChannel |
1.3.6.1.4.1.9.9.217.1.9.2.1.1.2 |
Indicates the fabric channel number associated with
the corresponding cc6kxbarTMChUtilModule. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
FabricChannelNumber |
|
|
cc6kxbarTMChUtilDirection |
1.3.6.1.4.1.9.9.217.1.9.2.1.1.3 |
Indicates the direction of traffic to be monitored. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
INTEGER |
ingress(1), egress(2) |
|
cc6kxbarTMChUtilEnable |
1.3.6.1.4.1.9.9.217.1.9.2.1.1.4 |
Specifies whether the traffic monitor feature is
enabled on a fabric channel for a given traffic
direction or not. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
TruthValue |
|
|
cc6kxbarTMChUtilInterval |
1.3.6.1.4.1.9.9.217.1.9.2.1.1.5 |
Specifies the interval at the end of which the
traffic utilization on a fabric channel for a
given traffic direction is compared against
its corresponding cc6kxbarTMChUtilThreshold. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
Unsigned32 |
1..4294967295 |
|
cc6kxbarTMChUtilThreshold |
1.3.6.1.4.1.9.9.217.1.9.2.1.1.6 |
Specifies the threshold of the traffic utilization
on a fabric channel for a given traffic direction. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
Percent |
|
|
cc6kxbarTMChUtilLogCount |
1.3.6.1.4.1.9.9.217.1.9.2.1.1.7 |
Indicates the number of times the following
events are logged on a fabric channel
for a given direction.
1. the traffic utilization on a fabric channel
for a given traffic direction has risen above its
corresponding configured threshold (as specified
by cc6kxbarTMChUtilThreshold), or has kept
staying above the configured threshold at a
logging interval (as specified by
cc6kxbarTMChUtilLogInterval).
2. the traffic utilization on a fabric channel
for a given traffic direction has fallen below
its corresponding configured threshold. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Counter32 |
|
|
cc6kxbarTMChUtilLastLogTime |
1.3.6.1.4.1.9.9.217.1.9.2.1.1.8 |
Indicates the last logging time of the
events as counted in the corresponding
cc6kxbarTMChUtilLogCount on a fabric channel
for a given traffic direction.
This object will contain 0-1-1,00:00:00.0 when
the corresponding cc6kxbarTMChUtilLogCount is zero. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DateAndTime |
|
|
cc6kxbarTMChUtilLogInterval |
1.3.6.1.4.1.9.9.217.1.9.2.2 |
Specifies the logging interval if the traffic
utilization for a fabric channel on a given
traffic direction keeps staying above its
corresponding cc6kxbarTMChUtilThreshold. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
Unsigned32 |
1..4294967295 |
|
cc6kxbarTMChUtilUtilization |
1.3.6.1.4.1.9.9.217.1.9.2.3 |
The traffic utilization on a fabric channel
for a given traffic direction included in the
notification currently being sent. |
Status: current |
Access: accessible-for-notify |
OBJECT-TYPE |
|
|
|
|
Percent |
|
|
cc6kxbarTMChUtilNotifEnable |
1.3.6.1.4.1.9.9.217.1.9.2.4 |
Specifies whether the generation of
cc6kxbarTMChUtilAboveNotif and cc6kxbarTMChUtilBelowNotif
notifications is enabled or not.
When this object is 'true', the generation of
cc6kxbarTMChUtilAboveNotif and cc6kxbarTMChUtilBelowNotif
notifications is enabled. When this object is 'false',
the generation of cc6kxbarTMChUtilAboveNotif and
cc6kxbarTMChUtilBelowNotif notifications is disabled. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
TruthValue |
|
|
cc6kxbarSwBusStatusChangeNotif |
1.3.6.1.4.1.9.9.217.0.1 |
A cc6kxbarSwBusStatusChangeNotif notification
is sent by the device when there is change
in switching status of the switching bus as
monitored by cc6kxbarSwBusSwitchingStatus. |
Status: current |
Access: read-write |
NOTIFICATION-TYPE |
|
|
|
cc6kxbarIntBusCRCErrExcdNotif |
1.3.6.1.4.1.9.9.217.0.2 |
A cc6kxbarIntBusCRCThreshExcdNotif notification
is sent by the system when the system has
detected that the internal bus CRC error on
a physical entity (such as a module) as specified
by entPhysicalName has exceeded the fatal threshold. |
Status: current |
Access: read-write |
NOTIFICATION-TYPE |
|
|
|
cc6kxbarIntBusCRCErrRcvrdNotif |
1.3.6.1.4.1.9.9.217.0.3 |
A cc6kxbarIntBusCRCErrRcvrdNotif notification
is sent by the system when the system has
recovered as the internal bus CRC error on
a physical entity (such as a module) as
specified by entPhysicalName has fallen below
the normal threshold. |
Status: current |
Access: read-write |
NOTIFICATION-TYPE |
|
|
|
cc6kxbarFlowCtrlBusThrExcdNotif |
1.3.6.1.4.1.9.9.217.0.4 |
A cc6kxbarFlowCtrlBusThrExcdNotif notification
is sent by the system when the system detects the
first occurrence of the system bus flow control FIFO
threshold exceeding on a physical entity
(such as a module) over the system allowed limit
when the object value of
cc6kxbarFlowCtrlBusFIFOThrMode is 'auto'. |
Status: current |
Access: read-write |
NOTIFICATION-TYPE |
|
|
|
cc6kxbarTMSwBusUtilAboveNotif |
1.3.6.1.4.1.9.9.217.0.5 |
This notification is sent when the switching bus
traffic utilization has risen above the configured
threshold (as specified by
cc6kxbarTMSwBusUtilThreshold), or has kept staying
above the configured threshold at a logging interval
(as specified by cc6kxbarTMSwBusUtilLogInterval).
The varbind entPhysicalDescr specifies the physical
entity (such as chassis) for which the
cc6kxbarTMSwBusUtilAboveNotif is sent. |
Status: current |
Access: read-write |
NOTIFICATION-TYPE |
|
|
|
cc6kxbarTMSwBusUtilBelowNotif |
1.3.6.1.4.1.9.9.217.0.6 |
This notification is sent when the switching bus
traffic utilization has fallen below the configured
threshold (as specified by
cc6kxbarTMSwBusUtilThreshold). The varbind
entPhysicalDescr specifies the physical entity
(such as chassis) for which the
cc6kxbarTMSwBusUtilBelowNotif is sent. |
Status: current |
Access: read-write |
NOTIFICATION-TYPE |
|
|
|
cc6kxbarTMChUtilAboveNotif |
1.3.6.1.4.1.9.9.217.0.7 |
This notification is sent when the traffic
utilization on a fabric channel for a given
traffic direction has risen above its
corresponding configured threshold (as
specified by cc6kxbarTMChUtilThreshold), or has
kept staying above the configured threshold at a
logging interval (as specified by
cc6kxbarTMChUtilLogInterval). The varbind
entPhysicalDescr specifies the physical entity
(such as chassis) for which the
cc6kxbarTMChUtilAboveNotif is sent. |
Status: current |
Access: read-write |
NOTIFICATION-TYPE |
|
|
|
cc6kxbarTMChUtilBelowNotif |
1.3.6.1.4.1.9.9.217.0.8 |
This notification is sent when the traffic
utilization on a fabric channel for a given
traffic direction has fallen below its
corresponding configured threshold (as
specified by cc6kxbarTMChUtilThreshold). The
varbind entPhysicalDescr specifies the
physical entity (such as chassis) for which
the cc6kxbarTMChUtilBelowNotif is sent. |
Status: current |
Access: read-write |
NOTIFICATION-TYPE |
|
|
|
cc6kxbarMIBCompliance |
1.3.6.1.4.1.9.9.217.3.1.2 |
The compliance statement for
the CISCO-CAT6K-CROSSBAR-MIB. |
Status: deprecated |
Access: read-write |
MODULE-COMPLIANCE |
|
|
|
cc6kxbarMIBComplianceVer1 |
1.3.6.1.4.1.9.9.217.3.1.3 |
The compliance statement for
the CISCO-CAT6K-CROSSBAR-MIB. |
Status: deprecated |
Access: read-write |
MODULE-COMPLIANCE |
|
|
|
cc6kxbarMIBComplianceVer2 |
1.3.6.1.4.1.9.9.217.3.1.4 |
The compliance statement for
the CISCO-CAT6K-CROSSBAR-MIB. |
Status: deprecated |
Access: read-write |
MODULE-COMPLIANCE |
|
|
|
cc6kxbarMIBComplianceVer3 |
1.3.6.1.4.1.9.9.217.3.1.5 |
The compliance statement for
the CISCO-CAT6K-CROSSBAR-MIB. |
Status: deprecated |
Access: read-write |
MODULE-COMPLIANCE |
|
|
|
cc6kxbarMIBComplianceVer4 |
1.3.6.1.4.1.9.9.217.3.1.6 |
The compliance statement for
the CISCO-CAT6K-CROSSBAR-MIB. |
Status: deprecated |
Access: read-write |
MODULE-COMPLIANCE |
|
|
|
cc6kxbarMIBComplianceVer5 |
1.3.6.1.4.1.9.9.217.3.1.7 |
The compliance statement for
the CISCO-CAT6K-CROSSBAR-MIB. |
Status: deprecated |
Access: read-write |
MODULE-COMPLIANCE |
|
|
|
cc6kxbarMIBComplianceVer6 |
1.3.6.1.4.1.9.9.217.3.1.8 |
The compliance statement for
the CISCO-CAT6K-CROSSBAR-MIB. |
Status: deprecated |
Access: read-write |
MODULE-COMPLIANCE |
|
|
|
cc6kxbarMIBComplianceVer7 |
1.3.6.1.4.1.9.9.217.3.1.9 |
The compliance statement for
the CISCO-CAT6K-CROSSBAR-MIB. |
Status: deprecated |
Access: read-write |
MODULE-COMPLIANCE |
|
|
|
cc6kxbarMIBComplianceVer8 |
1.3.6.1.4.1.9.9.217.3.1.10 |
The compliance statement for
the CISCO-CAT6K-CROSSBAR-MIB. |
Status: current |
Access: read-write |
MODULE-COMPLIANCE |
|
|
|
cc6kxbarModuleStatusGroup |
1.3.6.1.4.1.9.9.217.3.2.1 |
A collection of objects providing
configuration and operation of the crossbar
switching fabric module and switching capable
module.
cc6kxbarModuleStatusGroup object is superseded by cc6kxbarModuleStatusGroupVer1. |
Status: deprecated |
Access: read-write |
OBJECT-GROUP |
|
|
|
cc6kxbarChannelStatusGroup |
1.3.6.1.4.1.9.9.217.3.2.2 |
A collection of objects providing
status and configuration of the fabric channel. |
Status: current |
Access: read-write |
OBJECT-GROUP |
|
|
|
cc6kxbarChannelStatisticsGroup |
1.3.6.1.4.1.9.9.217.3.2.3 |
A collection of objects providing statistics for
the fabric channel.
cc6kxbarChannelStatisticsGroup object is superseded by cc6kxbarChannelStatisticsGroupVer1. |
Status: deprecated |
Access: read-write |
OBJECT-GROUP |
|
|
|
cc6kxbarFallbackGroup |
1.3.6.1.4.1.9.9.217.3.2.4 |
This object controls system fallback to bus-mode
after loss of switching fabric module. |
Status: current |
Access: read-write |
OBJECT-GROUP |
|
|
|
cc6kxbarBusOnlyAllowedGroup |
1.3.6.1.4.1.9.9.217.3.2.5 |
This object determines the value of
cc6kxbarModuleModeSwitchingMode of each module. |
Status: current |
Access: read-write |
OBJECT-GROUP |
|
|
|
cc6kxbarModuleStatusGroupVer1 |
1.3.6.1.4.1.9.9.217.3.2.6 |
A collection of objects providing
configuration and operation of the crossbar
switching fabric module and switching capable
module. |
Status: current |
Access: read-write |
OBJECT-GROUP |
|
|
|
cc6kxbarChannelStatisticsGroupVer1 |
1.3.6.1.4.1.9.9.217.3.2.7 |
A collection of objects providing statistics for
the fabric channel. |
Status: current |
Access: read-write |
OBJECT-GROUP |
|
|
|
cc6kxbarLcdBannerGroup |
1.3.6.1.4.1.9.9.217.3.2.8 |
A collection of objects providing configuration of
the lcd Banner of the fabric module. |
Status: current |
Access: read-write |
OBJECT-GROUP |
|
|
|
cc6kxbarChannelUtilGroup |
1.3.6.1.4.1.9.9.217.3.2.9 |
These object determines Input and Output Utilization of the
fabric channel. |
Status: current |
Access: read-write |
OBJECT-GROUP |
|
|
|
cc6kxbarChannelSpeedGroup |
1.3.6.1.4.1.9.9.217.3.2.10 |
A collection of objects providing the
speed of the fabric channel. |
Status: current |
Access: read-write |
OBJECT-GROUP |
|
|
|
cc6kxbarSwBusGroup |
1.3.6.1.4.1.9.9.217.3.2.11 |
A collection of objects for the switching bus switching
detection feature. |
Status: current |
Access: read-write |
OBJECT-GROUP |
|
|
|
cc6kxbarSwBusNotifGroup |
1.3.6.1.4.1.9.9.217.3.2.12 |
A collection of notifications for the switching
bus switching detection feature. |
Status: current |
Access: read-write |
NOTIFICATION-GROUP |
|
|
|
cc6kxbarTruncatedOperGroup |
1.3.6.1.4.1.9.9.217.3.2.13 |
A collection of objects providing the
operational truncated mode. |
Status: current |
Access: read-write |
OBJECT-GROUP |
|
|
|
cc6kxbarIntBusNotifControlGroup |
1.3.6.1.4.1.9.9.217.3.2.14 |
A collection of objects to control the notification
generation for internal bus. |
Status: current |
Access: read-write |
OBJECT-GROUP |
|
|
|
cc6kxbarIntBusCRCErrNotifGroup |
1.3.6.1.4.1.9.9.217.3.2.15 |
A collection of notifications for the
internal bus CRC error. |
Status: current |
Access: read-write |
NOTIFICATION-GROUP |
|
|
|
cc6kxbarIntBusCRCErrGroup |
1.3.6.1.4.1.9.9.217.3.2.16 |
A collection of objects to indicate the internal bus
CRC error information on a physical entity. |
Status: current |
Access: read-write |
OBJECT-GROUP |
|
|
|
cc6kxbarDcefOnlyModeAllowedGroup |
1.3.6.1.4.1.9.9.217.3.2.17 |
A collection of objects providing the configuration
and information about the dcef only mode feature. |
Status: current |
Access: read-write |
OBJECT-GROUP |
|
|
|
cc6kxbarForceBusModeGroup |
1.3.6.1.4.1.9.9.217.3.2.18 |
A collection of objects providing the configuration
and information about the force bus mode feature. |
Status: current |
Access: read-write |
OBJECT-GROUP |
|
|
|
cc6kxbarFlowCtrlNotifCtrlGroup |
1.3.6.1.4.1.9.9.217.3.2.19 |
A collection of objects to control the notification
generation for the system flow control feature. |
Status: current |
Access: read-write |
OBJECT-GROUP |
|
|
|
cc6kxbarFlowCtrlBusThreshGroup |
1.3.6.1.4.1.9.9.217.3.2.20 |
A collection of objects providing configuration
information about the system bus flow control FIFO
threshold. |
Status: current |
Access: read-write |
OBJECT-GROUP |
|
|
|
cc6kxbarFlowCtrlBusThrNotifGroup |
1.3.6.1.4.1.9.9.217.3.2.21 |
A collection of notifications for the system bus
flow control FIFO threshold exceeding. |
Status: current |
Access: read-write |
NOTIFICATION-GROUP |
|
|
|
cc6kxbarBusOnlyModeOperGroup |
1.3.6.1.4.1.9.9.217.3.2.22 |
A collection of objects providing the
operational bus mode. |
Status: current |
Access: read-write |
OBJECT-GROUP |
|
|
|
cc6kxbarSysCapPfcOperModeGroup |
1.3.6.1.4.1.9.9.217.3.2.23 |
A collection of objects providing the system
information of PFC operational mode. |
Status: current |
Access: read-write |
OBJECT-GROUP |
|
|
|
cc6kxbarSysCapSwitchResGroup |
1.3.6.1.4.1.9.9.217.3.2.24 |
A collection of objects providing the capacity
information of switching resources in the system. |
Status: current |
Access: read-write |
OBJECT-GROUP |
|
|
|
cc6kxbarChannelUtilGroup1 |
1.3.6.1.4.1.9.9.217.3.2.25 |
A collection of objects providing the information about peak
input and output utilization of a specific fabric channel on
a specific module. |
Status: current |
Access: read-write |
OBJECT-GROUP |
|
|
|
cc6kxbarSwBusGroup1 |
1.3.6.1.4.1.9.9.217.3.2.26 |
A collection of objects providing the information about
switching bus utilization. |
Status: current |
Access: read-write |
OBJECT-GROUP |
|
|
|
cc6kxbarErrorGroup |
1.3.6.1.4.1.9.9.217.3.2.27 |
A collection of objects providing error statistics for
a specific fabric channel on a specific module. |
Status: current |
Access: read-write |
OBJECT-GROUP |
|
|
|
cc6kxbarErrRcvryThresholdGroup |
1.3.6.1.4.1.9.9.217.3.2.28 |
A collection of objects providing the configuration
of thresholds on fabric link errors for the fabric
error recovery feature. |
Status: current |
Access: read-write |
OBJECT-GROUP |
|
|
|
cc6kxbarErrRcvrySwitchoverGroup |
1.3.6.1.4.1.9.9.217.3.2.29 |
A collection of objects providing the configuration
of fabric switchover on excessive fabric link errors
for the fabric error recovery feature. |
Status: current |
Access: read-write |
OBJECT-GROUP |
|
|
|
cc6kxbarErrRcvryPersLinkResGroup |
1.3.6.1.4.1.9.9.217.3.2.30 |
A collection of objects providing the configuration
of channel resync on excessive persistent fabric link
errors for the fabric error recovery feature. |
Status: current |
Access: read-write |
OBJECT-GROUP |
|
|
|
cc6kxbarErrRcvryChResyncGroup |
1.3.6.1.4.1.9.9.217.3.2.31 |
A collection of objects providing the configuration
for channel resync threshold for the fabric error
recovery feature. |
Status: current |
Access: read-write |
OBJECT-GROUP |
|
|
|
cc6kxbarTMSwBusUtilGroup |
1.3.6.1.4.1.9.9.217.3.2.32 |
A collection of objects providing configuration
information for traffic monitor feature on
the switching bus. |
Status: current |
Access: read-write |
OBJECT-GROUP |
|
|
|
cc6kxbarTMSwBusUtilNotifControlGroup |
1.3.6.1.4.1.9.9.217.3.2.33 |
A collection of objects to control the traffic monitor
notification generation on the switching bus. |
Status: current |
Access: read-write |
OBJECT-GROUP |
|
|
|
cc6kxbarTMSwBusUtilNotifObjectGroup |
1.3.6.1.4.1.9.9.217.3.2.34 |
A collection of objects included in the traffic monitor
notifications on the switching bus. |
Status: current |
Access: read-write |
OBJECT-GROUP |
|
|
|
cc6kxbarTMSwBusUtilNotifGroup |
1.3.6.1.4.1.9.9.217.3.2.35 |
A collection of traffic monitor notifications on the
switching bus. |
Status: current |
Access: read-write |
NOTIFICATION-GROUP |
|
|
|
cc6kxbarTMChUtilGroup |
1.3.6.1.4.1.9.9.217.3.2.36 |
A collection of objects providing the configuration
information for traffic monitor feature on fabric
channels. |
Status: current |
Access: read-write |
OBJECT-GROUP |
|
|
|
cc6kxbarTMChUtilNotifControlGroup |
1.3.6.1.4.1.9.9.217.3.2.37 |
A collection of objects to control the traffic monitor
notification generation on fabric channels. |
Status: current |
Access: read-write |
OBJECT-GROUP |
|
|
|
cc6kxbarTMChUtilNotifObjectGroup |
1.3.6.1.4.1.9.9.217.3.2.38 |
A collection of objects included in the traffic monitor
notifications on fabric channels. |
Status: current |
Access: read-write |
OBJECT-GROUP |
|
|
|
cc6kxbarTMChUtilNotifGroup |
1.3.6.1.4.1.9.9.217.3.2.39 |
A collection of traffic monitor notifications on
fabric channels. |
Status: current |
Access: read-write |
NOTIFICATION-GROUP |
|
|
|
cc6kxbarStatisticsLbusDropGroup |
1.3.6.1.4.1.9.9.217.3.2.40 |
A collection of objects providing information for
local bus drop packets statistics. |
Status: current |
Access: read-write |
OBJECT-GROUP |
|
|
|