CHS-MIB

File: CHS-MIB.mib (41177 bytes)

Imported modules

RFC1155-SMI RFC1213-MIB RFC-1212

Imported symbols

enterprises experimental IpAddress
TimeTicks Gauge Counter
DisplayString OBJECT-TYPE

Defined Types

UchasSlotEntry  
SEQUENCE    
  uchasSlotIndex INTEGER
  uchasSlotModuleType OBJECT IDENTIFIER
  uchasSlotLastChange TimeTicks
  uchasSlotModuleDescr DisplayString
  uchasSlotModuleVersion DisplayString
  uchasSlotModuleSerialNumber DisplayString
  uchasSlotModuleProductCode DisplayString
  uchasSlotStatFeEna INTEGER
  uchasSlotFeKey DisplayString
  uchasSlotNacConfig OCTET STRING
  uchasSlotSwitchSettings INTEGER
  uchasSlotRamInstalled INTEGER
  uchasSlotFlashInstalled INTEGER

UchasEntityEntry  
SEQUENCE    
  uchasEntityIndex INTEGER
  uchasEntityObjectID OBJECT IDENTIFIER
  uchasEntityDescr DisplayString
  uchasEntityVersion DisplayString
  uchasEntityOperStatus INTEGER
  uchasEntityTimeStamp TimeTicks

UchasPowerSupplyEntry  
SEQUENCE    
  uchasPowerSupplyIndex INTEGER
  uchasPowerSupplyDescr DisplayString
  uchasPowerSupplyOperStatus INTEGER
  uchasPowerSupplyFailures Counter

UchasPowerSupplyOutEntry  
SEQUENCE    
  uchasPowerSupplyOutPSIndex INTEGER
  uchasPowerSupplyOutIndex INTEGER
  uchasPowerSupplyOutStatus INTEGER
  uchasPowerSupplyOutNominalVolt INTEGER
  uchasPowerSupplyOutOfferedVolt INTEGER
  uchasPowerSupplyOutWarnings Counter

UchasEnvironEntry  
SEQUENCE    
  uchasEnvironIndex INTEGER
  uchasEnvironSensor OBJECT IDENTIFIER
  uchasEnvironStatus INTEGER
  uchasEnvironWarnings Counter
  uchasEnvironFailures Counter

UchasCmdEntry  
SEQUENCE    
  uchasCmdSlotIndex INTEGER
  uchasCmdMgtStationId OCTET STRING
  uchasCmdReqId INTEGER
  uchasCmdFunction INTEGER
  uchasCmdForce INTEGER
  uchasCmdParam OCTET STRING
  uchasCmdResult INTEGER
  uchasCmdCode INTEGER

UchasArSlotEntry  
SEQUENCE    
  uchasArSlotIndex INTEGER
  uchasArModuleInserted OCTET STRING
  uchasArModuleReinit OCTET STRING
  uchasArModuleRemoved OCTET STRING
  uchasArModuleNonoper OCTET STRING
  uchasArModuleWatchdog OCTET STRING

UchasArTimerEntry  
SEQUENCE    
  uchasArTimerIndex INTEGER
  uchasArTimerEna INTEGER
  uchasArTimerStartDate DisplayString
  uchasArTimerStartTime DisplayString
  uchasArTimerStopDate DisplayString
  uchasArTimerStopTime DisplayString
  uchasArTimerInterval INTEGER
  uchasArTimerState INTEGER
  uchasArTimerTriggers Counter

Defined Values

usr 1.3.6.1.4.1.429
OBJECT IDENTIFIER    

nas 1.3.6.1.4.1.429.1
OBJECT IDENTIFIER    

chs 1.3.6.1.4.1.429.1.1
OBJECT IDENTIFIER    

uchasSlot 1.3.6.1.4.1.429.1.1.1
OBJECT IDENTIFIER    

uchasSlotTable 1.3.6.1.4.1.429.1.1.1.1
A table that contains information about the slots in the chassis. For those slots that do not contain a physical module, the table will contain a conceptual row with the type of physical module set to 'uchasSlotEmpty'.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    UchasSlotEntry

uchasSlotEntry 1.3.6.1.4.1.429.1.1.1.1.1
A list of information for each slot in the chassis. Conceptual rows may not be created or deleted with SNMP operations, but rather, the Proxy agent running in the Network Management Card will automatically create and delete rows as cards are inserted and removed.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  UchasSlotEntry  

uchasSlotIndex 1.3.6.1.4.1.429.1.1.1.1.1.1
The slot number for which this entry contains management information. NAC slots are numbered from 1 to 16. The Network Management Card (NMC) goes in slot 17. For simplicity's sake, the corresponding NIC slot numbers will be 21 through 37. Rows will not exist in this table for slots 18 through 20.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..37  

uchasSlotModuleType 1.3.6.1.4.1.429.1.1.1.1.1.2
The type of physical module contained in this slot of the chassis. A value of uchasSlotEmpty indicates an empty slot. A value of uchasSlotUnknown indicates that the type of module is unknown.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OBJECT IDENTIFIER  

uchasSlotLastChange 1.3.6.1.4.1.429.1.1.1.1.1.3
The value of MIB-II's sysUpTime (in the agent supporting this chassis MIB) at which a module was last inserted or removed from this slot. If no module has been inserted or removed from this slot since the last time the network management card was re-initialized, then this object has a zero value.
Status: mandatory Access: read-only
OBJECT-TYPE    
  TimeTicks  

uchasSlotModuleDescr 1.3.6.1.4.1.429.1.1.1.1.1.4
A textual description of the module plugged into the slot.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..124)  

uchasSlotModuleVersion 1.3.6.1.4.1.429.1.1.1.1.1.5
A textual description of the version/revision level for this module's hardware.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..124)  

uchasSlotModuleSerialNumber 1.3.6.1.4.1.429.1.1.1.1.1.6
The serial number of the module present in the slot. If the slot is empty, this value will be a zero length string.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..31)  

uchasSlotModuleProductCode 1.3.6.1.4.1.429.1.1.1.1.1.7
The product code of the module present in the slot. For certain entries in the slot table the NMC will not be able to read product codes. In such cases the product code string will be NULL.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..8)  

uchasSlotStatFeEna 1.3.6.1.4.1.429.1.1.1.1.1.8
This object can be read to determine what options have been enabled in the NACs. It uses individual bits to represent the enable status of the features which are NAC specific.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER  

uchasSlotFeKey 1.3.6.1.4.1.429.1.1.1.1.1.9
This object sends the feature key to the appropriate NAC for enabling added cost features. When read, this object returns a null string.
Status: optional Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..22)  

uchasSlotNacConfig 1.3.6.1.4.1.429.1.1.1.1.1.10
This is a proprietary encoding of a module's view of the chassis NAC configuration as it is stored in the module. For modules not supporting chassis configuration storage, the values will be all 0.
Status: optional Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(0..160)  

uchasSlotSwitchSettings 1.3.6.1.4.1.429.1.1.1.1.1.11
This represents the DIP switch settings on the NAC. It is a bitmapped integer.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

uchasSlotRamInstalled 1.3.6.1.4.1.429.1.1.1.1.1.12
This represents the amount of DRAM memory installed on the NAC in Kbytes.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

uchasSlotFlashInstalled 1.3.6.1.4.1.429.1.1.1.1.1.13
This represents the amount of flash ROM memory installed on the NAC in Kbytes.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

uchasEntity 1.3.6.1.4.1.429.1.1.2
OBJECT IDENTIFIER    

uchasEntityTable 1.3.6.1.4.1.429.1.1.2.1
A table that contains information about the 'logical' networking devices (entities) in this chassis.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    UchasEntityEntry

uchasEntityEntry 1.3.6.1.4.1.429.1.1.2.1.1
Information concerning an entity in the chassis. Conceptual rows may not be created or deleted with SNMP operations, but rather, will be automatically created and deleted by the proxy agent running on the Network Management Card.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  UchasEntityEntry  

uchasEntityIndex 1.3.6.1.4.1.429.1.1.2.1.1.1
A unique index for the entity for which this entry contains information. For simplicity's sake, entity index values will be assigned according to the formula E=1000*S+I, where E is the entity index, S is the slot index, and I is the index of the entity on the specific card. For example, the third modem on a quad modem card that is in slot 5 has an entity index of 5003.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..65535  

uchasEntityObjectID 1.3.6.1.4.1.429.1.1.2.1.1.2
The specific type of entity. The value of this object is analogous to MIB-II's sysObjectID. In particular, it has the same value as would be returned if the MIB view identified by uchasIpAddress and uchasCommunity, were queried for sysObjectID.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OBJECT IDENTIFIER  

uchasEntityDescr 1.3.6.1.4.1.429.1.1.2.1.1.3
A textual description of the entity. The value of this object is analogous to MIB-II's sysDescr. In particular, it has the same value as would be returned if the MIB view identified by uchasIpAddress and uchasCommunity were queried for sysDescr.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..124)  

uchasEntityVersion 1.3.6.1.4.1.429.1.1.2.1.1.4
A textual description of the version/revision level for this entity's software.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..124)  

uchasEntityOperStatus 1.3.6.1.4.1.429.1.1.2.1.1.5
Provides operational status of the entity for which this row corresponds.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(1), outOfService(2), testing(3), operational(4), failed(5), loading(6)  

uchasEntityTimeStamp 1.3.6.1.4.1.429.1.1.2.1.1.6
The value of MIB-II's sysUpTime (in the NMC's proxy agent) at which this entity was last (re-)initialized.
Status: mandatory Access: read-only
OBJECT-TYPE    
  TimeTicks  

uchasConfig 1.3.6.1.4.1.429.1.1.3
OBJECT IDENTIFIER    

uchasType 1.3.6.1.4.1.429.1.1.3.1
An authoritative identification of the type of chassis. This object provides an easy and unambiguaous means for determining what kind of box is being managed.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OBJECT IDENTIFIER  

uchasDescr 1.3.6.1.4.1.429.1.1.3.2
A textual description of the specific chassis being managed.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..124)  

uchasDisplayName 1.3.6.1.4.1.429.1.1.3.3
A four digit name given to the chassis. The name will be displayed on the alpha-numeric display on the front panel of the Network Management Card in the given chassis.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..4)  

uchasPhysicalChanges 1.3.6.1.4.1.429.1.1.3.4
The number of physical changes that have occurred in the chassis since the agent was warm/cold started. This includes additions and removal of physical modules.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

uchasFrontPanelLedStates 1.3.6.1.4.1.429.1.1.3.5
This object is a proprietarily encoded octet string that is used by USR's management console to retrieve the front panel LED states (attributes) from all of the devices installed in the chassis by getting a single object.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(0..255)  

uchasFrontPanelLedColor 1.3.6.1.4.1.429.1.1.3.6
This object is a proprietary encoded octet string used to get the color of every LED from all the devices in the chassis.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(0..255)  

uchasNicStates 1.3.6.1.4.1.429.1.1.3.7
This object is a proprietary encoded octet string used to get the status of every NIC in the chassis.
Status: optional Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(0..255)  

uchasPowerSupply 1.3.6.1.4.1.429.1.1.4
OBJECT IDENTIFIER    

uchasPowerSupplyTable 1.3.6.1.4.1.429.1.1.4.1
A list of power supply entries, one for each power supply in the chassis. This table is a dense table, so rows appear for all possible power supplies that could be present in the given chassis.
Status: optional Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    UchasPowerSupplyEntry

uchasPowerSupplyEntry 1.3.6.1.4.1.429.1.1.4.1.1
There is one entry in the power supply table for each possible power supply in the chassis.
Status: optional Access: not-accessible
OBJECT-TYPE    
  UchasPowerSupplyEntry  

uchasPowerSupplyIndex 1.3.6.1.4.1.429.1.1.4.1.1.1
An index value that uniquely identifies a power supply.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER  

uchasPowerSupplyDescr 1.3.6.1.4.1.429.1.1.4.1.1.2
A textual description of the power supply.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..124)  

uchasPowerSupplyOperStatus 1.3.6.1.4.1.429.1.1.4.1.1.3
Actual status of the power supply represented by this entry in the power supply table.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), bad(2), good(3), empty(4)  

uchasPowerSupplyFailures 1.3.6.1.4.1.429.1.1.4.1.1.4
The number of times that uchasPowerSupplyOperStatus has gone to bad(4).
Status: optional Access: read-only
OBJECT-TYPE    
  Counter  

uchasPowerSupplyOutTable 1.3.6.1.4.1.429.1.1.4.2
A list of power supply output entries, one for each output of each power supply in the chassis.
Status: optional Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    UchasPowerSupplyOutEntry

uchasPowerSupplyOutEntry 1.3.6.1.4.1.429.1.1.4.2.1
There is one row in this table for each power supply output for each power supply in the chassis.
Status: optional Access: not-accessible
OBJECT-TYPE    
  UchasPowerSupplyOutEntry  

uchasPowerSupplyOutPSIndex 1.3.6.1.4.1.429.1.1.4.2.1.1
An index which specifies the power supply to which this output relates. The value of this index corresponds directly to values of the index for the power supply table.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER  

uchasPowerSupplyOutIndex 1.3.6.1.4.1.429.1.1.4.2.1.2
An index that, together with uchasPowerSupplyOutPSIndex, uniquely defines an output for the specified power supply.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER  

uchasPowerSupplyOutStatus 1.3.6.1.4.1.429.1.1.4.2.1.3
Actual status of the supply output. One of unknown(1), warning(2), or good(3).
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), warning(2), good(3)  

uchasPowerSupplyOutNominalVolt 1.3.6.1.4.1.429.1.1.4.2.1.4
In hundredths of a volt, the voltage the output is supposed to supply, such as -5V, which would be represented by the value -500, or +12V, which would correspond to a value of +1200.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER  

uchasPowerSupplyOutOfferedVolt 1.3.6.1.4.1.429.1.1.4.2.1.5
In hundredths of a volt, the voltage actually offered by the output. If uchasPowerSupplyOutStatus is good(4), the value 0 means offered voltage is not available.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER  

uchasPowerSupplyOutWarnings 1.3.6.1.4.1.429.1.1.4.2.1.6
The number of times uchasPowerSupplyOutputStatus has gone to warning(3).
Status: optional Access: read-only
OBJECT-TYPE    
  Counter  

uchasEnviron 1.3.6.1.4.1.429.1.1.5
OBJECT IDENTIFIER    

uchasEnvironTable 1.3.6.1.4.1.429.1.1.5.1
A list of environmental entries, one for each environmental sensor in the chassis.
Status: optional Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    UchasEnvironEntry

uchasEnvironEntry 1.3.6.1.4.1.429.1.1.5.1.1
Values for an environmental sensor in the chassis.
Status: optional Access: not-accessible
OBJECT-TYPE    
  UchasEnvironEntry  

uchasEnvironIndex 1.3.6.1.4.1.429.1.1.5.1.1.1
A index that uniquely identifies an environmental sensor.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER  

uchasEnvironSensor 1.3.6.1.4.1.429.1.1.5.1.1.2
The identification of the type of environmental sensor to which this entry applies.
Status: optional Access: read-only
OBJECT-TYPE    
  OBJECT IDENTIFIER  

uchasEnvironStatus 1.3.6.1.4.1.429.1.1.5.1.1.3
Actual status indicated by the sensor.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), bad(2), warning(3), good(4)  

uchasEnvironWarnings 1.3.6.1.4.1.429.1.1.5.1.1.4
The number of times uchasEnvironStatus has gone to warning(3).
Status: optional Access: read-only
OBJECT-TYPE    
  Counter  

uchasEnvironFailures 1.3.6.1.4.1.429.1.1.5.1.1.5
The number of times uchasEnvironStatus has gone to bad(2).
Status: optional Access: read-only
OBJECT-TYPE    
  Counter  

uchasKnownTypes 1.3.6.1.4.1.429.1.1.6
OBJECT IDENTIFIER    

uchasKnownChassis 1.3.6.1.4.1.429.1.1.6.1
OBJECT IDENTIFIER    

uchas17SlotChassis 1.3.6.1.4.1.429.1.1.6.1.1
OBJECT IDENTIFIER    

uchas7SlotChassis 1.3.6.1.4.1.429.1.1.6.1.2
OBJECT IDENTIFIER    

uchasKnownModules 1.3.6.1.4.1.429.1.1.6.2
OBJECT IDENTIFIER    

uchasSlotEmpty 1.3.6.1.4.1.429.1.1.6.2.1
OBJECT IDENTIFIER    

uchasSlotUnknown 1.3.6.1.4.1.429.1.1.6.2.2
OBJECT IDENTIFIER    

uchasNetwMgtCard 1.3.6.1.4.1.429.1.1.6.2.3
OBJECT IDENTIFIER    

uchasDualT1NAC 1.3.6.1.4.1.429.1.1.6.2.4
OBJECT IDENTIFIER    

uchasDualModemNAC 1.3.6.1.4.1.429.1.1.6.2.5
OBJECT IDENTIFIER    

uchasQuadModemNAC 1.3.6.1.4.1.429.1.1.6.2.6
OBJECT IDENTIFIER    

uchasTrGatewayNAC 1.3.6.1.4.1.429.1.1.6.2.7
OBJECT IDENTIFIER    

uchasX25GatewayNAC 1.3.6.1.4.1.429.1.1.6.2.8
OBJECT IDENTIFIER    

uchasDualV34ModemNAC 1.3.6.1.4.1.429.1.1.6.2.9
OBJECT IDENTIFIER    

uchasQuadV32DigitalModemNAC 1.3.6.1.4.1.429.1.1.6.2.10
OBJECT IDENTIFIER    

uchasQuadV32AnalogModemNAC 1.3.6.1.4.1.429.1.1.6.2.11
OBJECT IDENTIFIER    

uchasQuadV32DigAnlModemNAC 1.3.6.1.4.1.429.1.1.6.2.12
OBJECT IDENTIFIER    

uchasQuadV34DigModemNAC 1.3.6.1.4.1.429.1.1.6.2.13
OBJECT IDENTIFIER    

uchasQuadV34AnlModemNAC 1.3.6.1.4.1.429.1.1.6.2.14
OBJECT IDENTIFIER    

uchasQuadV34DigAnlModemNAC 1.3.6.1.4.1.429.1.1.6.2.15
OBJECT IDENTIFIER    

uchasSingleT1NAC 1.3.6.1.4.1.429.1.1.6.2.16
OBJECT IDENTIFIER    

uchasEthernetGatewayNAC 1.3.6.1.4.1.429.1.1.6.2.17
OBJECT IDENTIFIER    

uchasAccessServer 1.3.6.1.4.1.429.1.1.6.2.18
OBJECT IDENTIFIER    

uchas486TrGatewayNAC 1.3.6.1.4.1.429.1.1.6.2.19
OBJECT IDENTIFIER    

uchas486EthernetGatewayNAC 1.3.6.1.4.1.429.1.1.6.2.20
OBJECT IDENTIFIER    

uchasDualRS232NAC 1.3.6.1.4.1.429.1.1.6.2.22
OBJECT IDENTIFIER    

uchas486X25GatewayNAC 1.3.6.1.4.1.429.1.1.6.2.23
OBJECT IDENTIFIER    

uchasApplicationServerNAC 1.3.6.1.4.1.429.1.1.6.2.25
OBJECT IDENTIFIER    

uchasISDNGatewayNAC 1.3.6.1.4.1.429.1.1.6.2.26
OBJECT IDENTIFIER    

uchasISDNpriT1NAC 1.3.6.1.4.1.429.1.1.6.2.27
OBJECT IDENTIFIER    

uchasModemPoolManagmentNAC 1.3.6.1.4.1.429.1.1.6.2.29
OBJECT IDENTIFIER    

uchasModemPoolNetserverNAC 1.3.6.1.4.1.429.1.1.6.2.30
OBJECT IDENTIFIER    

uchasModemPoolV34ModemNAC 1.3.6.1.4.1.429.1.1.6.2.31
OBJECT IDENTIFIER    

uchasModemPoolISDNNAC 1.3.6.1.4.1.429.1.1.6.2.32
OBJECT IDENTIFIER    

uchasNTServerNAC 1.3.6.1.4.1.429.1.1.6.2.33
OBJECT IDENTIFIER    

uchasQuadV34AnalogG2NAC 1.3.6.1.4.1.429.1.1.6.2.34
OBJECT IDENTIFIER    

uchasQuadV34DigitalG2NAC 1.3.6.1.4.1.429.1.1.6.2.35
OBJECT IDENTIFIER    

uchasQuadV34DigAnlgG2NAC 1.3.6.1.4.1.429.1.1.6.2.36
OBJECT IDENTIFIER    

uchasNETServerFrameRelayNAC 1.3.6.1.4.1.429.1.1.6.2.37
OBJECT IDENTIFIER    

uchasNETServerTokenRingNAC 1.3.6.1.4.1.429.1.1.6.2.38
OBJECT IDENTIFIER    

uchasX2524ChannelNAC 1.3.6.1.4.1.429.1.1.6.2.39
OBJECT IDENTIFIER    

uchasDualT1NIC 1.3.6.1.4.1.429.1.1.6.2.1001
OBJECT IDENTIFIER    

uchasDualAlogMdmNIC 1.3.6.1.4.1.429.1.1.6.2.1002
OBJECT IDENTIFIER    

uchasQuadDgtlMdmNIC 1.3.6.1.4.1.429.1.1.6.2.1003
OBJECT IDENTIFIER    

uchasQuadAlogDgtlMdmNIC 1.3.6.1.4.1.429.1.1.6.2.1004
OBJECT IDENTIFIER    

uchasTokenRingNIC 1.3.6.1.4.1.429.1.1.6.2.1005
OBJECT IDENTIFIER    

uchasSingleT1NIC 1.3.6.1.4.1.429.1.1.6.2.1006
OBJECT IDENTIFIER    

uchasEthernetNIC 1.3.6.1.4.1.429.1.1.6.2.1007
OBJECT IDENTIFIER    

uchasShortHaulDualT1NIC 1.3.6.1.4.1.429.1.1.6.2.1008
OBJECT IDENTIFIER    

uchasDualAlogMgdIntlMdmNIC 1.3.6.1.4.1.429.1.1.6.2.1009
OBJECT IDENTIFIER    

uchasX25NIC 1.3.6.1.4.1.429.1.1.6.2.1010
OBJECT IDENTIFIER    

uchasQuadAlogNonMgdMdmNIC 1.3.6.1.4.1.429.1.1.6.2.1011
OBJECT IDENTIFIER    

uchasQuadAlogMgdIntlMdmNIC 1.3.6.1.4.1.429.1.1.6.2.1012
OBJECT IDENTIFIER    

uchasQuadAlogNonMgdIntlMdmNIC 1.3.6.1.4.1.429.1.1.6.2.1013
OBJECT IDENTIFIER    

uchasQuadLsdLiMgdMdmNIC 1.3.6.1.4.1.429.1.1.6.2.1014
OBJECT IDENTIFIER    

uchasQuadLsdLiNonMgdMdmNIC 1.3.6.1.4.1.429.1.1.6.2.1015
OBJECT IDENTIFIER    

uchasQuadLsdLiMgdIntlMdmNIC 1.3.6.1.4.1.429.1.1.6.2.1016
OBJECT IDENTIFIER    

uchasQuadLsdLiNonMgdIntlMdmNIC 1.3.6.1.4.1.429.1.1.6.2.1017
OBJECT IDENTIFIER    

uchasHSEthernetWithV35NIC 1.3.6.1.4.1.429.1.1.6.2.1018
OBJECT IDENTIFIER    

uchasHSEthernetWithoutV35NIC 1.3.6.1.4.1.429.1.1.6.2.1019
OBJECT IDENTIFIER    

uchasDualHighSpeedV35NIC 1.3.6.1.4.1.429.1.1.6.2.1020
OBJECT IDENTIFIER    

uchasQuadV35RS232LowSpeedNIC 1.3.6.1.4.1.429.1.1.6.2.1021
OBJECT IDENTIFIER    

uchasDualE1NIC 1.3.6.1.4.1.429.1.1.6.2.1022
OBJECT IDENTIFIER    

uchasShortHaulDualE1NIC 1.3.6.1.4.1.429.1.1.6.2.1023
OBJECT IDENTIFIER    

uchasKnownEntities 1.3.6.1.4.1.429.1.1.6.3
OBJECT IDENTIFIER    

uchasNetwMgtEntity 1.3.6.1.4.1.429.1.1.6.3.1
OBJECT IDENTIFIER    

uchasDualT1Entity 1.3.6.1.4.1.429.1.1.6.3.2
OBJECT IDENTIFIER    

uchasDS1Entity 1.3.6.1.4.1.429.1.1.6.3.3
OBJECT IDENTIFIER    

uchasModemEntity 1.3.6.1.4.1.429.1.1.6.3.4
OBJECT IDENTIFIER    

uchasDualStandardModemEntity 1.3.6.1.4.1.429.1.1.6.3.5
OBJECT IDENTIFIER    

uchasHSTModemEntity 1.3.6.1.4.1.429.1.1.6.3.6
OBJECT IDENTIFIER    

uchasV32ModemEntity 1.3.6.1.4.1.429.1.1.6.3.7
OBJECT IDENTIFIER    

uchasTokenRingEntity 1.3.6.1.4.1.429.1.1.6.3.8
OBJECT IDENTIFIER    

uchasX25GatewayEntity 1.3.6.1.4.1.429.1.1.6.3.9
OBJECT IDENTIFIER    

uchasDualStandardV32TerboMdEnt 1.3.6.1.4.1.429.1.1.6.3.10
OBJECT IDENTIFIER    

uchasV32TerboModemEntity 1.3.6.1.4.1.429.1.1.6.3.11
OBJECT IDENTIFIER    

uchasV32TerboFaxModemEntity 1.3.6.1.4.1.429.1.1.6.3.12
OBJECT IDENTIFIER    

uchasDualStandardV34Modem 1.3.6.1.4.1.429.1.1.6.3.13
OBJECT IDENTIFIER    

uchasV34ModemEntity 1.3.6.1.4.1.429.1.1.6.3.14
OBJECT IDENTIFIER    

uchasV34FaxModemEntity 1.3.6.1.4.1.429.1.1.6.3.15
OBJECT IDENTIFIER    

uchasSingleT1Entity 1.3.6.1.4.1.429.1.1.6.3.16
OBJECT IDENTIFIER    

uchasEthernetGatewayEntity 1.3.6.1.4.1.429.1.1.6.3.17
OBJECT IDENTIFIER    

uchasX25GatewaySubnetEntity 1.3.6.1.4.1.429.1.1.6.3.18
OBJECT IDENTIFIER    

uchasTokenRingAccSrvrEntity 1.3.6.1.4.1.429.1.1.6.3.19
OBJECT IDENTIFIER    

uchasEthernetAccSrvrEntity 1.3.6.1.4.1.429.1.1.6.3.20
OBJECT IDENTIFIER    

uchasDualRS232Entity 1.3.6.1.4.1.429.1.1.6.3.22
OBJECT IDENTIFIER    

uchasEnetFRIsdnNetservrEntity 1.3.6.1.4.1.429.1.1.6.3.23
OBJECT IDENTIFIER    

uchasIsdnPriT1Entity 1.3.6.1.4.1.429.1.1.6.3.24
OBJECT IDENTIFIER    

uchasTknRngIsdnNetserverEntity 1.3.6.1.4.1.429.1.1.6.3.25
OBJECT IDENTIFIER    

uchasEnetNetserverEntity 1.3.6.1.4.1.429.1.1.6.3.26
OBJECT IDENTIFIER    

uchasIsdnPriE1Entity 1.3.6.1.4.1.429.1.1.6.3.27
OBJECT IDENTIFIER    

uchasAnalogMdmNicEntity 1.3.6.1.4.1.429.1.1.6.3.1001
OBJECT IDENTIFIER    

uchasWellKnownSensors 1.3.6.1.4.1.429.1.1.6.4
OBJECT IDENTIFIER    

uchasSensorOther 1.3.6.1.4.1.429.1.1.6.4.1
OBJECT IDENTIFIER    

uchasSensorTemperature 1.3.6.1.4.1.429.1.1.6.4.2
OBJECT IDENTIFIER    

uchasSensorFans 1.3.6.1.4.1.429.1.1.6.4.3
OBJECT IDENTIFIER    

uchasCmd 1.3.6.1.4.1.429.1.1.7
OBJECT IDENTIFIER    

uchasCmdTable 1.3.6.1.4.1.429.1.1.7.1
The Chassis Command table contains an entry for each of the NIC and NAC slots in the chassis. It provides a means through which to take specific actions on one or more devices in the chassis at a card level. Device specific commands are not included here, but rather in the specific MIB used to manage the device.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    UchasCmdEntry

uchasCmdEntry 1.3.6.1.4.1.429.1.1.7.1.1
There is one entry in this table for each row in uchasSlotTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  UchasCmdEntry  

uchasCmdSlotIndex 1.3.6.1.4.1.429.1.1.7.1.1.1
This index uniquely identifies the slot to which the command being written is to take place. Values of uchasCmdSlotIndex correspond to values used to index uchasSlotTable.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

uchasCmdMgtStationId 1.3.6.1.4.1.429.1.1.7.1.1.2
This object is a generic read-write variable that a Management Station (MS) can use to guarantee that the results from a given command are the results of a command issued by that specific MS. Each MS must SET a unique value to this object when doing commands and GET the value of this object together with uchasCmdReqId and uchasCmdResult to detect interference from other MSs.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(0..8)  

uchasCmdReqId 1.3.6.1.4.1.429.1.1.7.1.1.3
Ths object contains the value of the request-id field in the SNMP PDU which invoked the current or most recent command on the device in the specified slot of the chassis. If the request-id is unknown or undefined, this value contains the value zero.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

uchasCmdFunction 1.3.6.1.4.1.429.1.1.7.1.1.4
A control variable used to start and stop operator-initiated commands. A command is initiated by setting this object to a value other than noCommand(1). When the value noCommand(1) is written to this object, no action is taken, unless a command is in progress, in which case the command is aborted.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER noCommand(1), removeFromService(2), restoreToService(3), hardwareReset(4), softwareDownload(5)  

uchasCmdForce 1.3.6.1.4.1.429.1.1.7.1.1.5
In some cases, the devices in the chassis may be in a state such that certain commands could adversely affect connections or other device specific operations. In such cases, a command with uchasCmdForce set to noForce will result in a warning. If the operator elects to ignore such warnings, uchasCmdForce can be set to force in the command request and the command will be carried out regardless of its potentially hazzardous effects.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER force(1), noForce(2)  

uchasCmdParam 1.3.6.1.4.1.429.1.1.7.1.1.6
This object contains parameters that are specific to the particular command being issued. In some cases, there will be no additional parameters required.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(0..24)  

uchasCmdResult 1.3.6.1.4.1.429.1.1.7.1.1.7
This object contains the result of the most recently requested test, or the value none(1) if not commands have been requested since the last reset. Note that this facility provides no provision for saving the results of one command when starting another, as could be required if used by multiple managers concurrently.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER none(1), success(2), inProgress(3), notSupported(4), unAbleToRun(5), aborted(6), failed(7)  

uchasCmdCode 1.3.6.1.4.1.429.1.1.7.1.1.8
The value of this object upon command completion indicates a further description of what went wrong if the command was unsuccessful. This object is also used as an indication of the in progress status of the software download command.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noError(1), unable(2), unrecognizedCommand(6), slotEmpty(8), noResponse(12), connected(14), unsupportedCommand(20), nonManagedDevice(21), deviceDisabled(22), userInterfaceActive(58), badFlashRomID(61), badFlashVoltage(62), flashEraseError(63), eraseSequenceError(64), eraseExecutionError(65), receiveBufferOverflow(66), badAddressInData(67), badProgramVoltage(68), programmingDataError(69), programCodeError(70), invalidCodeError(71), romCrcBad(72), pendingSoftwareDownload(73), ramCrcBad(74), invalidRomId(75), sdlTrigger(76), downloadingSdlFile(77), crcTestingSdlFile(78), queryWorkSpaceSize(79), executeLoadedProgram(80), erasingFlash(81), downloadingNacFile(82), resetingNac(83), cardIdMismatch(84), cardIdUnknown(85), tftpTimeout(86), flashEraseTimeout(87), invalidFileHeader(88)  

uchasTrapEnable 1.3.6.1.4.1.429.1.1.8
OBJECT IDENTIFIER    

uchasModuleInsertedTrapEna 1.3.6.1.4.1.429.1.1.8.1
Enables the generation of a trap when a card is inserted into the chassis. This parameter is effective across all slots in the chassis.
Status: optional Access: read-write
OBJECT-TYPE    
  INTEGER enableTrap(1), disableAll(2), enableLog(3), enableAll(4)  

uchasModuleRemovedTrapEna 1.3.6.1.4.1.429.1.1.8.2
Enables the generation of a trap when a card is removed from the chassis. This parameter is effective across all slots in the chassis.
Status: optional Access: read-write
OBJECT-TYPE    
  INTEGER enableTrap(1), disableAll(2), enableLog(3), enableAll(4)  

uchasPSUWarningTrapEna 1.3.6.1.4.1.429.1.1.8.3
Enables the generation of a trap when a power supply enters a warning state, such as one or more output voltages being out of range. This parameter is effective across all PSUs in the chassis.
Status: optional Access: read-write
OBJECT-TYPE    
  INTEGER enableTrap(1), disableAll(2), enableLog(3), enableAll(4)  

uchasPSUFailureTrapEna 1.3.6.1.4.1.429.1.1.8.4
Enables the generation of a trap when a power supply fails and has been automatically shut down due to overvoltage, overcurrent, etc. This parameter is effective across all PSUs in the chassis.
Status: optional Access: read-write
OBJECT-TYPE    
  INTEGER enableTrap(1), disableAll(2), enableLog(3), enableAll(4)  

uchasTempWarningTrapEna 1.3.6.1.4.1.429.1.1.8.5
Enables the generation of a trap when the temperature in the chassis, as detected by the NMC, becomes excessive.
Status: optional Access: read-write
OBJECT-TYPE    
  INTEGER enableTrap(1), disableAll(2), enableLog(3), enableAll(4)  

uchasFanFailureTrapEna 1.3.6.1.4.1.429.1.1.8.6
Enables the generation of a trap when the fan in the chassis is not rotating with sufficient speed to cool the power supplies.
Status: optional Access: read-write
OBJECT-TYPE    
  INTEGER enableTrap(1), disableAll(2), enableLog(3), enableAll(4)  

uchasEntityWatchdogTrapEna 1.3.6.1.4.1.429.1.1.8.7
Enables the generation of a trap when a logical networking entity in the chassis undergoes a watchdog timeout event, indicating software failure.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enableTrap(1), disableAll(2), enableLog(3), enableAll(4)  

uchasEntityMgtBusFailTrapEna 1.3.6.1.4.1.429.1.1.8.8
Enables the generation of a trap when the SNMP proxy agent in the NMC is unable to communicate properly with a logical networking entity in the chassis.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enableTrap(1), disableAll(2), enableLog(3), enableAll(4)  

uchasAutoResponse 1.3.6.1.4.1.429.1.1.9
OBJECT IDENTIFIER    

uchasArPsuVoltOutOfRange 1.3.6.1.4.1.429.1.1.9.1
This script is triggered when the NMC detects that voltage levels, for at least one power supply on the mid plane, are outside the normal operating range.
Status: optional Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(0..20)  

uchasArPsuFailed 1.3.6.1.4.1.429.1.1.9.2
This script is triggered when the NMC detects an over-voltage or over-current condition present in the PSU.
Status: optional Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(0..20)  

uchasArFanFailed 1.3.6.1.4.1.429.1.1.9.3
This script is triggered when the fan speed becomes dangerously slow as to risk damage to inadequate cooling of the chassis.
Status: optional Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(0..20)  

uchasArHubTempOutOfRange 1.3.6.1.4.1.429.1.1.9.4
This script is triggered when the chassis temperature is outside the specified normal operating range.
Status: optional Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(0..20)  

uchasArTimer1 1.3.6.1.4.1.429.1.1.9.5
This script is triggered when the first general purpose timer expires.
Status: optional Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(0..20)  

uchasArTimer2 1.3.6.1.4.1.429.1.1.9.6
This script is triggered when the second general purpose timer expires.
Status: optional Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(0..20)  

uchasArTimer3 1.3.6.1.4.1.429.1.1.9.7
This script is triggered when the third general purpose timer expires.
Status: optional Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(0..20)  

uchasArTimer4 1.3.6.1.4.1.429.1.1.9.8
This script is triggered when the fourth general purpose timer expires.
Status: optional Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(0..20)  

uchasArSlotTable 1.3.6.1.4.1.429.1.1.9.9
A table that contains auto response scripts, in the chassis, that act on a particular slot.
Status: optional Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    UchasArSlotEntry

uchasArSlotEntry 1.3.6.1.4.1.429.1.1.9.9.1
A list of auto response scripts, in the chassis, that act on a slot.
Status: optional Access: not-accessible
OBJECT-TYPE    
  UchasArSlotEntry  

uchasArSlotIndex 1.3.6.1.4.1.429.1.1.9.9.1.1
The slot number for which this entry contains an auto response script. NAC slots are numbered from 1 to 16. The Network Management Card (NMC) goes into slot 17. To keep things simple, the corresponding NIC slot numbers are from 21 to 37. Rows for slots 18 to 20 do not exist.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER 1..37  

uchasArModuleInserted 1.3.6.1.4.1.429.1.1.9.9.1.2
This script is triggered when a module is inserted in the chassis.
Status: optional Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(0..20)  

uchasArModuleReinit 1.3.6.1.4.1.429.1.1.9.9.1.3
This script is triggered when the following occur: chassis power transitions from off to on; a module is inserted in the chassis; software download has just been completed to a module; a module is restored to service; or a module is reset (hardware).
Status: optional Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(0..20)  

uchasArModuleRemoved 1.3.6.1.4.1.429.1.1.9.9.1.4
This script is triggered when a module is physically removed from the chassis.
Status: optional Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(0..20)  

uchasArModuleNonoper 1.3.6.1.4.1.429.1.1.9.9.1.5
This script is triggered when the following occur: software download to a module has just been started; a module is removed from service; or a module has failed (i.e. all entities on that module have failed).
Status: optional Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(0..20)  

uchasArModuleWatchdog 1.3.6.1.4.1.429.1.1.9.9.1.6
This script is triggered when one or more module entities experience a watchdog time-out.
Status: optional Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(0..20)  

uchasArTimers 1.3.6.1.4.1.429.1.1.10
OBJECT IDENTIFIER    

uchasArTimerTable 1.3.6.1.4.1.429.1.1.10.1
A table that contains general purpose global timer parameters. These timers act on an entire chassis.
Status: optional Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    UchasArTimerEntry

uchasArTimerEntry 1.3.6.1.4.1.429.1.1.10.1.1
A list of parameters for general purpose global timers.
Status: optional Access: not-accessible
OBJECT-TYPE    
  UchasArTimerEntry  

uchasArTimerIndex 1.3.6.1.4.1.429.1.1.10.1.1.1
The number of general purpose global timers.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER 1..4  

uchasArTimerEna 1.3.6.1.4.1.429.1.1.10.1.1.2
Enable or disable the specified global timer.
Status: optional Access: read-write
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

uchasArTimerStartDate 1.3.6.1.4.1.429.1.1.10.1.1.3
This object determines the date on which the timer becomes active. This date is compared against the system date, time and time zone defined in management entity. Default=01/01/95
Status: optional Access: read-write
OBJECT-TYPE    
  DisplayString Size(5..8)  

uchasArTimerStartTime 1.3.6.1.4.1.429.1.1.10.1.1.4
This object determines the time on which the timer becomes active. This time is compared against the system date, time and time zone defined in management entity. Default=00:00:00
Status: optional Access: read-write
OBJECT-TYPE    
  DisplayString Size(5..8)  

uchasArTimerStopDate 1.3.6.1.4.1.429.1.1.10.1.1.5
This object specifies the date on which this timer becomes passive. This date is compared against the system date, time and time zone defined in management entity. The timer will not be active if the timer stop date and time is less than system date and time. Default = 01/01/95
Status: optional Access: read-write
OBJECT-TYPE    
  DisplayString Size(5..8)  

uchasArTimerStopTime 1.3.6.1.4.1.429.1.1.10.1.1.6
This object specifies the time on which this timer becomes passive. This time is compared against the system date, time and time zone defined in management entity. The timer will not be active if the timer stop date and time is less than system date and time. Default = 00:00:00
Status: optional Access: read-write
OBJECT-TYPE    
  DisplayString Size(5..8)  

uchasArTimerInterval 1.3.6.1.4.1.429.1.1.10.1.1.7
The interval in seconds between each timer firing. The firings will happen at each interval after the timer starts until the date/time specified if the following 2 conditions are met. First, TimerInterval must be less than or equal to the timer active period. Second, The start date/time is less than the stop date/time. The timer will fire only once at stop date/time if a zero value has been assigned to this object. Default = 0. Max 259000 sec = 30 days.
Status: optional Access: read-write
OBJECT-TYPE    
  INTEGER 0..2678400  

uchasArTimerState 1.3.6.1.4.1.429.1.1.10.1.1.8
This object indicates the current state of the global timer.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER init(1), passive(2), active(3)  

uchasArTimerTriggers 1.3.6.1.4.1.429.1.1.10.1.1.9
This object indicates the number of times that a global timer has triggered since the last system boot time.
Status: optional Access: read-only
OBJECT-TYPE    
  Counter