CHIPCOMMIB

File: CHIPCOMMIB.mib (564277 bytes)

Imported modules

RFC1155-SMI RFC-1212 RFC1213-MIB
RFC-1215

Imported symbols

enterprises IpAddress Counter
Gauge TimeTicks OBJECT-TYPE
DisplayString TRAP-TYPE

Defined Types

MacAddress  
OCTET STRING Size(6)    

OlAgentsEntry  
SEQUENCE    
  olAgentsSlotIndex INTEGER
  olAgentsStationAddr OCTET STRING
  olAgentsIpAddress IpAddress
  olAgentsMasterStatus INTEGER
  olAgentsMasterPriority INTEGER
  ocAgentsSubSlot INTEGER

OlEnvPSEntry  
SEQUENCE    
  olEnvPSIndex INTEGER
  olEnvPSAdminState INTEGER
  olEnvPSOperStatus INTEGER

OlEnvEntry  
SEQUENCE    
  olEnvType INTEGER
  olEnvStatus INTEGER

OlModEntry  
SEQUENCE    
  olModSlotIndex INTEGER
  olModType INTEGER
  olModClass INTEGER
  olModDescr DisplayString
  olModVersion DisplayString
  olModVendor INTEGER
  olModResetModule INTEGER
  olModConfigToDips INTEGER
  olModConfigured INTEGER
  olModNetwork INTEGER
  olModNetworkType INTEGER
  olModStatus INTEGER
  olModNumPorts INTEGER
  olModNumTrunks INTEGER

OlPortEntry  
SEQUENCE    
  olPortSlotIndex INTEGER
  olPortIndex INTEGER
  olPortType INTEGER
  olPortConnector INTEGER
  olPortStatus INTEGER
  olPortAdminState INTEGER
  olPortNetwork INTEGER
  olPortNetworkType INTEGER
  olPortAlertFilter INTEGER

OlTrunkEntry  
SEQUENCE    
  olTrunkSlotIndex INTEGER
  olTrunkIndex INTEGER
  olTrunkType INTEGER
  olTrunkConnector INTEGER
  olTrunkStatus INTEGER
  olTrunkAdminState INTEGER
  olTrunkWrapState INTEGER
  olTrunkNeighbor INTEGER

Ol50nnMCTLModEntry  
SEQUENCE    
  ol50nnMCTLModSlotIndex INTEGER
  ol50nnMCTLModTempStatus INTEGER

Ol51nnMMGTModEntry  
SEQUENCE    
  ol51nnMMGTModSlotIndex INTEGER
  ol51nnMMGTModMasterPriority INTEGER
  ol51nnMMGTModMasterStatus INTEGER
  ol51nnMMGTModStationAddr OCTET STRING

Ol51nnMMGTPortEntry  
SEQUENCE    
  ol51nnMMGTPortSlotIndex INTEGER
  ol51nnMMGTPortIndex INTEGER
  ol51nnMMGTIpAddress IpAddress

Ol51nnMFIBModEntry  
SEQUENCE    
  ol51nnMFIBModSlotIndex INTEGER
  ol51nnMFIBModDipNetwork INTEGER
  ol51nnMFIBModLLW INTEGER
  ol51nnMFIBModDipLLW INTEGER

Ol51nnMFIBPortEntry  
SEQUENCE    
  ol51nnMFIBPortSlotIndex INTEGER
  ol51nnMFIBPortIndex INTEGER
  ol51nnMFIBPortAdminState INTEGER
  ol51nnMFIBPortBuddySlot INTEGER
  ol51nnMFIBPortBuddyPort INTEGER
  ol51nnMFIBPortDipAdminState INTEGER

Ol51nnMUTPModEntry  
SEQUENCE    
  ol51nnMUTPModSlotIndex INTEGER
  ol51nnMUTPModDipNetwork INTEGER
  ol51nnMUTPModCrossover INTEGER
  ol51nnMUTPModDipCrossover INTEGER
  ol51nnMUTPModFFL INTEGER
  ol51nnMUTPModDipFFL INTEGER

Ol51nnMUTPPortEntry  
SEQUENCE    
  ol51nnMUTPPortSlotIndex INTEGER
  ol51nnMUTPPortIndex INTEGER
  ol51nnMUTPPortAdminState INTEGER
  ol51nnMUTPPortBuddySlot INTEGER
  ol51nnMUTPPortBuddyPort INTEGER
  ol51nnMUTPPortDipAdminState INTEGER
  ol51nnMUTPPortLinkInteg INTEGER
  ol51nnMUTPPortDipLinkInteg INTEGER
  ol51nnMUTPPortSquelch INTEGER
  ol51nnMUTPPortDipSquelch INTEGER

Ol51nnMTPModEntry  
SEQUENCE    
  ol51nnMTPModSlotIndex INTEGER
  ol51nnMTPModDipNetwork INTEGER
  ol51nnMTPModCrossover INTEGER
  ol51nnMTPModDipCrossover INTEGER

Ol51nnMTPPortEntry  
SEQUENCE    
  ol51nnMTPPortSlotIndex INTEGER
  ol51nnMTPPortIndex INTEGER
  ol51nnMTPPortAdminState INTEGER
  ol51nnMTPPortBuddySlot INTEGER
  ol51nnMTPPortBuddyPort INTEGER
  ol51nnMTPPortDipAdminState INTEGER
  ol51nnMTPPortLinkInteg INTEGER
  ol51nnMTPPortDipLinkInteg INTEGER
  ol51nnMTPPortSquelch INTEGER
  ol51nnMTPPortDipSquelch INTEGER

Ol51nnMBNCModEntry  
SEQUENCE    
  ol51nnMBNCModSlotIndex INTEGER
  ol51nnMBNCModDipNetwork INTEGER

Ol51nnMBNCPortEntry  
SEQUENCE    
  ol51nnMBNCPortSlotIndex INTEGER
  ol51nnMBNCPortIndex INTEGER
  ol51nnMBNCPortDipAdminState INTEGER
  ol51nnMBNCPortDipTermination INTEGER
  ol51nnMBNCPortDipGround INTEGER

Ol51nnBEEModEntry  
SEQUENCE    
  ol51nnBEEModSlotIndex INTEGER
  ol51nnBEEModStationAddr OCTET STRING
  ol51nnBEEModProtocols DisplayString

Ol51nnBEEPortEntry  
SEQUENCE    
  ol51nnBEEPortSlotIndex INTEGER
  ol51nnBEEPortIndex INTEGER
  ol51nnBEEPortIpAddress IpAddress
  ol51nnBEEPortDipNetwork INTEGER
  ol51nnBEEPortDefNetwork INTEGER

Ol51nnRESModEntry  
SEQUENCE    
  ol51nnRESModSlotIndex INTEGER
  ol51nnRESModStationAddr OCTET STRING
  ol51nnRESModProtocols DisplayString

Ol51nnRESPortEntry  
SEQUENCE    
  ol51nnRESPortSlotIndex INTEGER
  ol51nnRESPortIndex INTEGER
  ol51nnRESPortIpAddress IpAddress
  ol51nnRESPortDipNetwork INTEGER
  ol51nnRESPortDefNetwork INTEGER

Ol51nnREEModEntry  
SEQUENCE    
  ol51nnREEModSlotIndex INTEGER
  ol51nnREEModStationAddr OCTET STRING
  ol51nnREEModProtocols DisplayString

Ol51nnREEPortEntry  
SEQUENCE    
  ol51nnREEPortSlotIndex INTEGER
  ol51nnREEPortIndex INTEGER
  ol51nnREEPortIpAddress IpAddress
  ol51nnREEPortDipNetwork INTEGER
  ol51nnREEPortDefNetwork INTEGER

Ol51nnMAUIFModEntry  
SEQUENCE    
  ol51nnMAUIFModSlotIndex INTEGER

Ol51nnMAUIFPortEntry  
SEQUENCE    
  ol51nnMAUIFPortSlotIndex INTEGER
  ol51nnMAUIFPortIndex INTEGER
  ol51nnMAUIFPortAdminState INTEGER
  ol51nnMAUIFPortBuddySlot INTEGER
  ol51nnMAUIFPortBuddyPort INTEGER
  ol51nnMAUIFPortDipAdminState INTEGER
  ol51nnMAUIFPortDipNetwork INTEGER

Ol51nnMAUIMModEntry  
SEQUENCE    
  ol51nnMAUIMModSlotIndex INTEGER

Ol51nnMAUIMPortEntry  
SEQUENCE    
  ol51nnMAUIMPortSlotIndex INTEGER
  ol51nnMAUIMPortIndex INTEGER
  ol51nnMAUIMPortAdminState INTEGER
  ol51nnMAUIMPortBuddySlot INTEGER
  ol51nnMAUIMPortBuddyPort INTEGER
  ol51nnMAUIMPortDipAdminState INTEGER
  ol51nnMAUIMPortDipNetwork INTEGER
  ol51nnMAUIMPortSQETest INTEGER
  ol51nnMAUIMPortDipSQETest INTEGER
  ol51nnMAUIMPortCollision INTEGER
  ol51nnMAUIMPortDipCollision INTEGER
  ol51nnMAUIMPortHalfStep INTEGER
  ol51nnMAUIMPortDipHalfStep INTEGER

Ol5208MTPModEntry  
SEQUENCE    
  ol5208MTPModSlotIndex INTEGER
  ol5208MTPModBypsAdminState INTEGER
  ol5208MTPModBypsOperState INTEGER
  ol5208MTPModDipCableImp INTEGER

Ol5208MTPPortEntry  
SEQUENCE    
  ol5208MTPPortSlotIndex INTEGER
  ol5208MTPPortIndex INTEGER
  ol5208MTPPortDipAdminState INTEGER
  ol5208MTPPortStationType INTEGER

Ol5208MTPTrunkEntry  
SEQUENCE    
  ol5208MTPTrunkSlotIndex INTEGER
  ol5208MTPTrunkIndex INTEGER
  ol5208MTPTrunkDipAdminState INTEGER
  ol5208MTPTrunkCableMon INTEGER
  ol5208MTPTrunkDipCableMon INTEGER
  ol5208MTPTrunkNetMapState INTEGER
  ol5208MTPTrunkExtBcnRecovery INTEGER

Ol51nnMFPModEntry  
SEQUENCE    
  ol51nnMFPModSlotIndex INTEGER

Ol51nnMFPPortEntry  
SEQUENCE    
  ol51nnMFPPortSlotIndex INTEGER
  ol51nnMFPPortIndex INTEGER
  ol51nnMFPPortAdminState INTEGER
  ol51nnMFPPortBuddySlot INTEGER
  ol51nnMFPPortBuddyPort INTEGER
  ol51nnMFPPortDipAdminState INTEGER
  ol51nnMFPPortDipNetwork INTEGER
  ol51nnMFPPortLLW INTEGER
  ol51nnMFPPortDipLLW INTEGER
  ol51nnMFPPortHipwr INTEGER
  ol51nnMFPPortDipHipwr INTEGER

Ol51nnMFBPModEntry  
SEQUENCE    
  ol51nnMFBPModSlotIndex INTEGER

Ol51nnMFBPPortEntry  
SEQUENCE    
  ol51nnMFBPPortSlotIndex INTEGER
  ol51nnMFBPPortIndex INTEGER
  ol51nnMFBPPortAdminState INTEGER
  ol51nnMFBPPortBuddySlot INTEGER
  ol51nnMFBPPortBuddyPort INTEGER
  ol51nnMFBPPortDipAdminState INTEGER
  ol51nnMFBPPortDipNetwork INTEGER
  ol51nnMFBPPortLLW INTEGER
  ol51nnMFBPPortDipLLW INTEGER
  ol51nnMFBPPortHipwr INTEGER
  ol51nnMFBPPortDipHipwr INTEGER

Ol51nnMTPLModEntry  
SEQUENCE    
  ol51nnMTPLModSlotIndex INTEGER
  ol51nnMTPLModDipNetwork INTEGER

Ol51nnMTPLPortEntry  
SEQUENCE    
  ol51nnMTPLPortSlotIndex INTEGER
  ol51nnMTPLPortIndex INTEGER
  ol51nnMTPLPortAdminState INTEGER
  ol51nnMTPLPortBuddySlot INTEGER
  ol51nnMTPLPortBuddyPort INTEGER
  ol51nnMTPLPortDipAdminState INTEGER
  ol51nnMTPLPortLinkInteg INTEGER
  ol51nnMTPLPortDipLinkInteg INTEGER
  ol51nnMTPLPortSquelch INTEGER
  ol51nnMTPLPortJabber INTEGER
  ol51nnMTPLPortDipJabber INTEGER

Ol51nnMTPPLModEntry  
SEQUENCE    
  ol51nnMTPPLModSlotIndex INTEGER

Ol51nnMTPPLPortEntry  
SEQUENCE    
  ol51nnMTPPLPortSlotIndex INTEGER
  ol51nnMTPPLPortIndex INTEGER
  ol51nnMTPPLPortAdminState INTEGER
  ol51nnMTPPLPortBuddySlot INTEGER
  ol51nnMTPPLPortBuddyPort INTEGER
  ol51nnMTPPLPortDipAdminState INTEGER
  ol51nnMTPPLPortDipNetwork INTEGER
  ol51nnMTPPLPortLinkInteg INTEGER
  ol51nnMTPPLPortDipLinkInteg INTEGER
  ol51nnMTPPLPortSquelch INTEGER
  ol51nnMTPPLPortJabber INTEGER
  ol51nnMTPPLPortDipJabber INTEGER

Ol52nnMTPModEntry  
SEQUENCE    
  ol52nnMTPModSlotIndex INTEGER
  ol52nnMTPModRingSpeed INTEGER
  ol52nnMTPModDipRingSpeed INTEGER
  ol52nnMTPModCableImp INTEGER
  ol52nnMTPModDipCableImp INTEGER

Ol52nnMTPPortEntry  
SEQUENCE    
  ol52nnMTPPortSlotIndex INTEGER
  ol52nnMTPPortIndex INTEGER
  ol52nnMTPPortDipAdminState INTEGER
  ol52nnMTPPortStationType INTEGER

Ol52nnMTPTrunkEntry  
SEQUENCE    
  ol52nnMTPTrunkSlotIndex INTEGER
  ol52nnMTPTrunkIndex INTEGER
  ol52nnMTPTrunkDipAdminState INTEGER

Ol52nnMFRModEntry  
SEQUENCE    
  ol52nnMFRModSlotIndex INTEGER
  ol52nnMFRModRingSpeed INTEGER
  ol52nnMFRModDipRingSpeed INTEGER

Ol52nnMFRPortEntry  
SEQUENCE    
  ol52nnMFRPortSlotIndex INTEGER
  ol52nnMFRPortIndex INTEGER
  ol52nnMFRPortDipAdminState INTEGER
  ol52nnMFRPortCableImp INTEGER
  ol52nnMFRPortStationType INTEGER

Ol52nnMFRTrunkEntry  
SEQUENCE    
  ol52nnMFRTrunkSlotIndex INTEGER
  ol52nnMFRTrunkIndex INTEGER
  ol52nnMFRTrunkDipAdminState INTEGER
  ol52nnMFRTrunkCableMon INTEGER
  ol52nnMFRTrunkDipCableMon INTEGER
  ol52nnMFRTrunkCompMode INTEGER
  ol52nnMFRTrunkDipCompMode INTEGER
  ol52nnMFRTrunkNetMapState INTEGER
  ol52nnMFRTrunkExtBcnRecovery INTEGER
  ol52nnMFRTrunkBuddySlot INTEGER
  ol52nnMFRTrunkAdminState INTEGER

Ol51nnMTSModEntry  
SEQUENCE    
  ol51nnMTSModSlotIndex INTEGER
  ol51nnMTSModProtocols DisplayString
  ol51nnMTSModIpAddress IpAddress
  ol51nnMTSModTCPPort INTEGER
  ol51nnMTSModStationAddr OCTET STRING
  ol51nnMTSModDipNetwork INTEGER
  ol51nnMTSModCPURev DisplayString

Ol51nnMTSPortEntry  
SEQUENCE    
  ol51nnMTSPortSlotIndex INTEGER
  ol51nnMTSPortIndex INTEGER
  ol51nnMTSPortAdminState INTEGER
  ol51nnMTSPortOperState INTEGER

Ol51nnMFLModEntry  
SEQUENCE    
  ol51nnMFLModSlotIndex INTEGER
  ol51nnMFLModDipNetwork INTEGER

Ol51nnMFLPortEntry  
SEQUENCE    
  ol51nnMFLPortSlotIndex INTEGER
  ol51nnMFLPortIndex INTEGER
  ol51nnMFLPortAdminState INTEGER
  ol51nnMFLPortBuddySlot INTEGER
  ol51nnMFLPortBuddyPort INTEGER
  ol51nnMFLPortDipAdminState INTEGER

Ol50nnMRCTLModEntry  
SEQUENCE    
  ol50nnMRCTLModSlotIndex INTEGER
  ol50nnMRCTLModOperState INTEGER
  ol50nnMRCTLModClockStatus INTEGER
  ol50nnMRCTLModTempStatus INTEGER

Ol51nnMFBModEntry  
SEQUENCE    
  ol51nnMFBModSlotIndex INTEGER
  ol51nnMFBModDipNetwork INTEGER
  ol51nnMFBModLLW INTEGER
  ol51nnMFBModDipLLW INTEGER

Ol51nnMFBPortEntry  
SEQUENCE    
  ol51nnMFBPortSlotIndex INTEGER
  ol51nnMFBPortIndex INTEGER
  ol51nnMFBPortAdminState INTEGER
  ol51nnMFBPortBuddySlot INTEGER
  ol51nnMFBPortBuddyPort INTEGER
  ol51nnMFBPortDipAdminState INTEGER

Ol53nnMFBMICModEntry  
SEQUENCE    
  ol53nnMFBMICModSlotIndex INTEGER
  ol53nnMFBMICModDownStreamModule INTEGER
  ol53nnMFBMICModUpStreamModule INTEGER
  ol53nnMFBMICModDownStreamOperPath INTEGER
  ol53nnMFBMICModUpStreamOperPath INTEGER
  ol53nnMFBMICModRingInfo OCTET STRING

Ol53nnMFBMICPortEntry  
SEQUENCE    
  ol53nnMFBMICPortSlotIndex INTEGER
  ol53nnMFBMICPortIndex INTEGER
  ol53nnMFBMICPortConfig INTEGER
  ol53nnMFBMICPortPcmState INTEGER
  ol53nnMFBMICPortConnectState INTEGER
  ol53nnMFBMICPortNeighbor INTEGER
  ol53nnMFBMICPortRemoteMACIndicated INTEGER
  ol53nnMFBMICPortBSFlag INTEGER
  ol53nnMFBMICPortPCWithhold INTEGER
  ol53nnMFBMICPortLerCondition INTEGER

Ol53nnMFBMICTrunkEntry  
SEQUENCE    
  ol53nnMFBMICTrunkSlotIndex INTEGER
  ol53nnMFBMICTrunkIndex INTEGER

Ol53nnMFIBSTModEntry  
SEQUENCE    
  ol53nnMFIBSTModSlotIndex INTEGER
  ol53nnMFIBSTModDownStreamModule INTEGER
  ol53nnMFIBSTModUpStreamModule INTEGER
  ol53nnMFIBSTModDownStreamOperPath INTEGER
  ol53nnMFIBSTModUpStreamOperPath INTEGER
  ol53nnMFIBSTModRingInfo OCTET STRING

Ol53nnMFIBSTPortEntry  
SEQUENCE    
  ol53nnMFIBSTPortSlotIndex INTEGER
  ol53nnMFIBSTPortIndex INTEGER
  ol53nnMFIBSTPortConfig INTEGER
  ol53nnMFIBSTPortPcmState INTEGER
  ol53nnMFIBSTPortConnectState INTEGER
  ol53nnMFIBSTPortNeighbor INTEGER
  ol53nnMFIBSTPortRemoteMACIndicated INTEGER
  ol53nnMFIBSTPortBSFlag INTEGER
  ol53nnMFIBSTPortPCWithhold INTEGER
  ol53nnMFIBSTPortLerCondition INTEGER

Ol53nnMFIBSTTrunkEntry  
SEQUENCE    
  ol53nnMFIBSTTrunkSlotIndex INTEGER
  ol53nnMFIBSTTrunkIndex INTEGER

Ol53nnMSTPModEntry  
SEQUENCE    
  ol53nnMSTPModSlotIndex INTEGER
  ol53nnMSTPModDownStreamModule INTEGER
  ol53nnMSTPModUpStreamModule INTEGER
  ol53nnMSTPModDownStreamOperPath INTEGER
  ol53nnMSTPModUpStreamOperPath INTEGER
  ol53nnMSTPModRingInfo OCTET STRING

Ol53nnMSTPPortEntry  
SEQUENCE    
  ol53nnMSTPPortSlotIndex INTEGER
  ol53nnMSTPPortIndex INTEGER
  ol53nnMSTPPortConfig INTEGER
  ol53nnMSTPPortPcmState INTEGER
  ol53nnMSTPPortConnectState INTEGER
  ol53nnMSTPPortNeighbor INTEGER
  ol53nnMSTPPortRemoteMACIndicated INTEGER
  ol53nnMSTPPortBSFlag INTEGER
  ol53nnMSTPPortPCWithhold INTEGER
  ol53nnMSTPPortLerCondition INTEGER
  ol53nnMSTPPortPersonality INTEGER

Ol53nnMSTPTrunkEntry  
SEQUENCE    
  ol53nnMSTPTrunkSlotIndex INTEGER
  ol53nnMSTPTrunkIndex INTEGER

Ol53nnMTDDIModEntry  
SEQUENCE    
  ol53nnMTDDIModSlotIndex INTEGER
  ol53nnMTDDIModDownStreamModule INTEGER
  ol53nnMTDDIModUpStreamModule INTEGER
  ol53nnMTDDIModDownStreamOperPath INTEGER
  ol53nnMTDDIModUpStreamOperPath INTEGER
  ol53nnMTDDIModRingInfo OCTET STRING

Ol53nnMTDDIPortEntry  
SEQUENCE    
  ol53nnMTDDIPortSlotIndex INTEGER
  ol53nnMTDDIPortIndex INTEGER
  ol53nnMTDDIPortConfig INTEGER
  ol53nnMTDDIPortPcmState INTEGER
  ol53nnMTDDIPortConnectState INTEGER
  ol53nnMTDDIPortNeighbor INTEGER
  ol53nnMTDDIPortRemoteMACIndicated INTEGER
  ol53nnMTDDIPortBSFlag INTEGER
  ol53nnMTDDIPortPCWithhold INTEGER
  ol53nnMTDDIPortLerCondition INTEGER

Ol53nnMTDDITrunkEntry  
SEQUENCE    
  ol53nnMTDDITrunkSlotIndex INTEGER
  ol53nnMTDDITrunkIndex INTEGER

Ol51nnMTPCLModEntry  
SEQUENCE    
  ol51nnMTPCLModSlotIndex INTEGER
  ol51nnMTPCLModMonitorConn INTEGER
  ol51nnMTPCLModConn1Network INTEGER
  ol51nnMTPCLModConn2Network INTEGER
  ol51nnMTPCLModConn1DipNetwork INTEGER
  ol51nnMTPCLModConn2DipNetwork INTEGER
  ol51nnMTPCLModAutoPartition INTEGER

Ol51nnMTPCLPortEntry  
SEQUENCE    
  ol51nnMTPCLPortSlotIndex INTEGER
  ol51nnMTPCLPortIndex INTEGER
  ol51nnMTPCLPortAdminState INTEGER
  ol51nnMTPCLPortBuddySlot INTEGER
  ol51nnMTPCLPortBuddyPort INTEGER
  ol51nnMTPCLPortDipAdminState INTEGER
  ol51nnMTPCLPortLinkInteg INTEGER
  ol51nnMTPCLPortDipLinkInteg INTEGER

Ol52nnBTTModEntry  
SEQUENCE    
  ol52nnBTTModSlotIndex INTEGER
  ol52nnBTTModBridgeType INTEGER
  ol52nnBTTModSoftwareVersion DisplayString
  ol52nnBTTModSRBridgeNo INTEGER
  ol52nnBTTModNetworkStatus INTEGER

Ol52nnBTTPortEntry  
SEQUENCE    
  ol52nnBTTPortSlotIndex INTEGER
  ol52nnBTTPortIndex INTEGER
  ol52nnBTTPortConnector INTEGER
  ol52nnBTTPortSTAPState INTEGER
  ol52nnBTTPortIpAddress IpAddress
  ol52nnBTTPortMACAddress OCTET STRING
  ol52nnBTTPortThroughput Gauge
  ol52nnBTTPortForwarding Gauge
  ol52nnBTTPortSRRingNo INTEGER
  ol52nnBTTPortRingSpeed INTEGER

Ol52nnBTTTrunkEntry  
SEQUENCE    
  ol52nnBTTTrunkSlotIndex INTEGER
  ol52nnBTTTrunkIndex INTEGER

Ol52nnMMGTModEntry  
SEQUENCE    
  ol52nnMMGTModSlotIndex INTEGER
  ol52nnMMGTModMasterPriority INTEGER
  ol52nnMMGTModMasterStatus INTEGER
  ol52nnMMGTModStationAddr OCTET STRING
  ol52nnMMGTModRingSpeed INTEGER
  ol52nnMMGTModNetworkStatus INTEGER
  ol52nnMMGTModMasterNetwork INTEGER
  ol52nnMMGTModLocalMACAddress MacAddress
  ol52nnMMGTModMACAddressType INTEGER
  ol52nnMMGTModActiveMACAddress MacAddress

Ol52nnMMGTPortEntry  
SEQUENCE    
  ol52nnMMGTPortSlotIndex INTEGER
  ol52nnMMGTPortIndex INTEGER
  ol52nnMMGTPortIpAddress IpAddress

Ol52nnMMGTTrunkEntry  
SEQUENCE    
  ol52nnMMGTTrunkSlotIndex INTEGER
  ol52nnMMGTTrunkIndex INTEGER
  ol52nnMMGTTrunkCableMon INTEGER
  ol52nnMMGTTrunkNetMapState INTEGER
  ol52nnMMGTTrunkExtBcnRecovery INTEGER

Ol51nnIxModEntry  
SEQUENCE    
  ol51nnIxModSlotIndex INTEGER
  ol51nnIxModSwType INTEGER
  ol51nnIxModStationAddr OCTET STRING
  ol51nnIxModDipPromDefaults INTEGER
  ol51nnIxModProtocols DisplayString

Ol51nnIxPortEntry  
SEQUENCE    
  ol51nnIxPortSlotIndex INTEGER
  ol51nnIxPortIndex INTEGER
  ol51nnIxPortDipAdminState INTEGER
  ol51nnIxPortSTAPState INTEGER
  ol51nnIxPortIpAddress IpAddress
  ol51nnIxPortDipNetwork INTEGER
  ol51nnIxPortDefNetwork INTEGER

Ol53nnMMGTModEntry  
SEQUENCE    
  ol53nnMMGTModSlotIndex INTEGER
  ol53nnMMGTModMasterPriority INTEGER
  ol53nnMMGTModMasterStatus INTEGER
  ol53nnMMGTModStationAddr OCTET STRING
  ol53nnMMGTModIpAddress IpAddress
  ol53nnMMGTModDownStreamMAC OCTET STRING
  ol53nnMMGTModUpStreamMAC OCTET STRING
  ol53nnMMGTModfddiMACPath INTEGER
  ol53nnMMGTModDownStreamModule INTEGER
  ol53nnMMGTModUpStreamModule INTEGER
  ol53nnMMGTModDownStreamOperPath INTEGER
  ol53nnMMGTModUpStreamOperPath INTEGER
  ol53nnMMGTModRingInfo OCTET STRING

Ol53nnMMGTPortEntry  
SEQUENCE    
  ol53nnMMGTPortSlotIndex INTEGER
  ol53nnMMGTPortIndex INTEGER
  ol53nnMMGTPortConfig INTEGER
  ol53nnMMGTPortPcmState INTEGER
  ol53nnMMGTPortConnectState INTEGER
  ol53nnMMGTPortNeighbor INTEGER
  ol53nnMMGTPortRemoteMACIndicated INTEGER
  ol53nnMMGTPortBSFlag INTEGER
  ol53nnMMGTPortPCWithhold INTEGER
  ol53nnMMGTPortLerCondition INTEGER

Ol53nnMMGTTrunkEntry  
SEQUENCE    
  ol53nnMMGTTrunkSlotIndex INTEGER
  ol53nnMMGTTrunkIndex INTEGER

Ol50nnMHCTLModEntry  
SEQUENCE    
  ol50nnMHCTLModSlotIndex INTEGER
  ol50nnMHCTLModOperState INTEGER
  ol50nnMHCTLModClockStatus INTEGER
  ol50nnMHCTLModTempStatus INTEGER
  ol50nnMHCTLModPDBStatus INTEGER
  ol50nnMHCTLModDipCh1ActCol INTEGER
  ol50nnMHCTLModDipCh2ActCol INTEGER
  ol50nnMHCTLModDipCh3ActCol INTEGER

Ol50nnMRCLSModEntry  
SEQUENCE    
  ol50nnMRCLSModSlotIndex INTEGER
  ol50nnMRCLSModOperState INTEGER
  ol50nnMRCLSModClockStatus INTEGER
  ol50nnMRCLSModTempStatus INTEGER

Ol51nnMTPLSModEntry  
SEQUENCE    
  ol51nnMTPLSModSlotIndex INTEGER
  ol51nnMTPLSModDipNetwork INTEGER
  ol51nnMTPLSModAutoPartition INTEGER

Ol51nnMTPLSPortEntry  
SEQUENCE    
  ol51nnMTPLSPortSlotIndex INTEGER
  ol51nnMTPLSPortIndex INTEGER
  ol51nnMTPLSPortAdminState INTEGER
  ol51nnMTPLSPortDipAdminState INTEGER
  ol51nnMTPLSPortDipSecurity INTEGER
  ol51nnMTPLSPortBuddySlot INTEGER
  ol51nnMTPLSPortBuddyPort INTEGER
  ol51nnMTPLSPortLinkInteg INTEGER
  ol51nnMTPLSPortDipLinkInteg INTEGER

Oc61nnMTPLPortEntry  
SEQUENCE    
  oc61nnMTPLPortSlotIndex INTEGER
  oc61nnMTPLPortIndex INTEGER
  oc61nnMTPLPortAdminState INTEGER
  oc61nnMTPLPortBuddySlot INTEGER
  oc61nnMTPLPortBuddyPort INTEGER
  oc61nnMTPLPortDipNetwork INTEGER
  oc61nnMTPLPortLinkInteg INTEGER
  oc61nnMTPLPortAutoPolarity INTEGER

Oc61nnMTPLModEntry  
SEQUENCE    
  oc61nnMTPLModSlotIndex INTEGER
  oc61nnMTPLModSubSlotIndex INTEGER
  oc61nnMTPLModBootVersion DisplayString
  oc61nnMTPLModDipNVRam INTEGER

Oc61nnMCARModEntry  
SEQUENCE    
  oc61nnMCARModSlotIndex INTEGER
  oc61nnMCARModSubSlotIndex INTEGER
  oc61nnMCARModBootVersion DisplayString

Oc61nnMFBPPortEntry  
SEQUENCE    
  oc61nnMFBPPortSlotIndex INTEGER
  oc61nnMFBPPortIndex INTEGER
  oc61nnMFBPPortAdminState INTEGER
  oc61nnMFBPPortBuddySlot INTEGER
  oc61nnMFBPPortBuddyPort INTEGER
  oc61nnMFBPPortDipNetwork INTEGER
  oc61nnMFBPPortHipwr INTEGER

Oc61nnMFBPModEntry  
SEQUENCE    
  oc61nnMFBPModSlotIndex INTEGER
  oc61nnMFBPModSubSlotIndex INTEGER
  oc61nnMFBPModBootVersion DisplayString
  oc61nnMFBPModDipNVRam INTEGER

Ol60nnMRCTLModEntry  
SEQUENCE    
  ol60nnMRCTLModSlotIndex INTEGER
  ol60nnMRCTLModOperState INTEGER
  ol60nnMRCTLModClockStatus INTEGER
  ol60nnMRCTLModTempStatus INTEGER

Oc60nnMRCTLModEntry  
SEQUENCE    
  oc60nnMRCTLModSlotIndex INTEGER
  oc60nnMRCTLModSubSlotIndex INTEGER
  oc60nnMRCTLModBootVersion DisplayString
  oc60nnMRCTLModOperState INTEGER
  oc60nnMRCTLModClockStatus INTEGER
  oc60nnMRCTLModTempStatus INTEGER
  oc60nnMRCTLModAtoDConverterStatus INTEGER
  oc60nnMRCTLModPS1Status INTEGER
  oc60nnMRCTLModPS2Status INTEGER
  oc60nnMRCTLModPS3Status INTEGER
  oc60nnMRCTLModPS4Status INTEGER

Oc61nnDMGTModEntry  
SEQUENCE    
  oc61nnDMGTModSlotIndex INTEGER
  oc61nnDMGTModSubSlotIndex INTEGER
  oc61nnDMGTModBootVersion DisplayString
  oc61nnDMGTModIpAddress IpAddress
  oc61nnDMGTModSubnetMask IpAddress
  oc61nnDMGTModDefaultGateway IpAddress
  oc61nnDMGTModStationAddr MacAddress
  oc61nnDMGTModInterfaceMode INTEGER
  oc61nnDMGTModRMONHostStatsMode INTEGER

Oc60nnMMGTModEntry  
SEQUENCE    
  oc60nnMMGTModSlotIndex INTEGER
  oc60nnMMGTModSubSlotIndex INTEGER
  oc60nnMMGTModBootVersion DisplayString
  oc60nnMMGTModMasterPriority INTEGER
  oc60nnMMGTModMasterStatus INTEGER
  oc60nnMMGTModHubSerial DisplayString

Ol52nnMECModEntry  
SEQUENCE    
  ol52nnMECModSlotIndex INTEGER
  ol52nnMECModSoftwareVersion DisplayString
  ol52nnMECModSystemStatusCode DisplayString
  ol52nnMECModRingSpeed INTEGER
  ol52nnMECModNetworkStatus INTEGER
  ol52nnMECModIpAddress IpAddress
  ol52nnMECModMACStationAddr OCTET STRING

Ol52nnMECPortEntry  
SEQUENCE    
  ol52nnMECPortSlotIndex INTEGER
  ol52nnMECPortIndex INTEGER

Ol52nnMECTrunkEntry  
SEQUENCE    
  ol52nnMECTrunkSlotIndex INTEGER
  ol52nnMECTrunkIndex INTEGER

Ol41nnHMTPModEntry  
SEQUENCE    
  ol41nnHMTPModSlotIndex INTEGER
  ol41nnHMTPModSerialNo DisplayString
  ol41nnHMTPModProtocols DisplayString
  ol41nnHMTPModIpAddress IpAddress

Ol41nnHMTPPortEntry  
SEQUENCE    
  ol41nnHMTPPortSlotIndex INTEGER
  ol41nnHMTPPortIndex INTEGER
  ol41nnHMTPPortReset INTEGER
  ol41nnHMTPPortLinkInteg INTEGER

Ol41nnHETPModEntry  
SEQUENCE    
  ol41nnHETPModSlotIndex INTEGER
  ol41nnHETPModSerialNo DisplayString

Ol41nnHETPPortEntry  
SEQUENCE    
  ol41nnHETPPortSlotIndex INTEGER
  ol41nnHETPPortIndex INTEGER
  ol41nnHETPPortReset INTEGER
  ol41nnHETPPortLinkInteg INTEGER

OlModSummaryEntry  
SEQUENCE    
  olModSummarySlotIndex INTEGER
  olModSummaryInfo OCTET STRING

OcModEntry  
SEQUENCE    
  ocModSlotIndex INTEGER
  ocModSubSlotIndex INTEGER
  ocModType INTEGER
  ocModClass INTEGER
  ocModDescr DisplayString
  ocModVersion DisplayString
  ocModVendor INTEGER
  ocModResetModule INTEGER
  ocModConfigToDips INTEGER
  ocModConfigured INTEGER
  ocModNetwork INTEGER
  ocModNetworkType INTEGER
  ocModStatus INTEGER
  ocModNumPorts INTEGER
  ocModNumTrunks INTEGER
  ocModNumSubSlots INTEGER

OlNetDPEntry  
SEQUENCE    
  olNetDPDataPath INTEGER
  olNetDPNetID INTEGER

OlNetSecurityMACEntry  
SEQUENCE    
  olNetSecurityMACSlotIndex INTEGER
  olNetSecurityMACPortIndex INTEGER
  olNetSecurityMACAddress MacAddress
  olNetSecurityMACMode INTEGER
  olNetSecurityMACStatus INTEGER

OlNetOlSecAddrEntry  
SEQUENCE    
  olNetOlSecAddrSlotIndex INTEGER
  olNetOlSecAddrPortIndex INTEGER
  olNetOlSecAddrAddress MacAddress
  olNetOlSecAddrStatus INTEGER

OlNetOlSecControlEntry  
SEQUENCE    
  olNetOlSecControlSlotIndex INTEGER
  olNetOlSecControlPortIndex INTEGER
  olNetOlSecControlMode INTEGER
  olNetOlSecControlSecType INTEGER
  olNetOlSecControlActOnIntr INTEGER
  olNetOlSecControlClearAddrs INTEGER
  olNetOlSecControlAutolearnMask INTEGER

OlNetOlSecLearnEntry  
SEQUENCE    
  olNetOlSecLearnSlotIndex INTEGER
  olNetOlSecLearnPortIndex INTEGER
  olNetOlSecLearnAddress MacAddress
  olNetOlSecLearnStatus INTEGER

OlNetOlSecIntruderEntry  
SEQUENCE    
  olNetOlSecIntruderChronIndex INTEGER
  olNetOlSecIntruderSlot INTEGER
  olNetOlSecIntruderPort INTEGER
  olNetOlSecIntruderAddress MacAddress
  olNetOlSecIntruderTimeSince TimeTicks
  olNetOlSecIntruderDisabled INTEGER

OlNetOlSecPortIntrEntry  
SEQUENCE    
  olNetOlSecPortIntrSlotIndex INTEGER
  olNetOlSecPortIntrPortIndex INTEGER
  olNetOlSecPortIntrChronIndex INTEGER
  olNetOlSecPortIntrAddress MacAddress
  olNetOlSecPortIntrTimeSince TimeTicks
  olNetOlSecPortIntrDisabled INTEGER

OlEnetStatsEntry  
SEQUENCE    
  olEnetStatsNetID INTEGER
  olEnetStatsFramesRcvdOks Counter
  olEnetStatsOctetsRcvdOks Counter
  olEnetStatsMcastRcvdOks Counter
  olEnetStatsBcastRcvdOks Counter
  olEnetStatsFrameTooLongs Counter
  olEnetStatsAlignmentErrors Counter
  olEnetStatsFCSErrors Counter
  olEnetStatsRunts Counter
  olEnetStatsLocalColls Counter
  olEnetStatsDropEvents Counter

OlEnetStatsModEntry  
SEQUENCE    
  olEnetStatsModNetID INTEGER
  olEnetStatsModSlotIndex INTEGER
  olEnetStatsModFramesRcvdOks Counter
  olEnetStatsModOctetsRcvdOks Counter
  olEnetStatsModMcastRcvdOks Counter
  olEnetStatsModBcastRcvdOks Counter
  olEnetStatsModFrameTooLongs Counter
  olEnetStatsModAlignmentErrors Counter
  olEnetStatsModFCSErrors Counter
  olEnetStatsModRunts Counter

OlEnetStatsPortEntry  
SEQUENCE    
  olEnetStatsPortNetID INTEGER
  olEnetStatsPortSlotIndex INTEGER
  olEnetStatsPortIndex INTEGER
  olEnetStatsPortFramesRcvdOks Counter
  olEnetStatsPortOctetsRcvdOks Counter
  olEnetStatsPortMcastRcvdOks Counter
  olEnetStatsPortBcastRcvdOks Counter
  olEnetStatsPortFrameTooLongs Counter
  olEnetStatsPortAlignmentErrors Counter
  olEnetStatsPortFCSErrors Counter
  olEnetStatsPortRunts Counter
  olEnetStatsPortSrcAddrChanges Counter
  olEnetStatsPortLastSrcAddr OCTET STRING Size(6)
  olEnetStatsPortLastErrAddr OCTET STRING Size(6)

OlEnetMapEntry  
SEQUENCE    
  olEnetMapNetID INTEGER
  olEnetMapAddress OCTET STRING
  olEnetMapSlotIndex INTEGER
  olEnetMapPortIndex INTEGER
  olEnetMapFrames Counter
  olEnetMapOctets Counter
  olEnetMapTime TimeTicks

ChipRptrRptrInfoEntry  
SEQUENCE    
  chipRptrRptrInfoSlotIndex INTEGER
  chipRptrRptrInfoNetID INTEGER
  chipRptrGroupCapacity INTEGER
  chipRptrOperStatus INTEGER
  chipRptrHealthText DisplayString
  chipRptrReset INTEGER
  chipRptrNonDisruptTest INTEGER
  chipRptrTotalPartitionedPorts Gauge

ChipRptrGroupEntry  
SEQUENCE    
  chipRptrGroupSlotIndex INTEGER
  chipRptrGroupNetID INTEGER
  chipRptrGroupIndex INTEGER
  chipRptrGroupDescr DisplayString
  chipRptrGroupObjectID OBJECT IDENTIFIER
  chipRptrGroupOperStatus INTEGER
  chipRptrGroupLastOperStatusChange TimeTicks
  chipRptrGroupPortCapacity INTEGER

ChipRptrPortEntry  
SEQUENCE    
  chipRptrPortSlotIndex INTEGER
  chipRptrPortNetID INTEGER
  chipRptrPortGroupIndex INTEGER
  chipRptrPortIndex INTEGER
  chipRptrPortAdminStatus INTEGER
  chipRptrPortAutoPartitionState INTEGER
  chipRptrPortOperStatus INTEGER

ChipRptrMonitorRptrEntry  
SEQUENCE    
  chipRptrMonitorSlotIndex INTEGER
  chipRptrMonitorNetID INTEGER
  chipRptrMonitorTransmitCollisions Counter

ChipRptrMonitorGroupEntry  
SEQUENCE    
  chipRptrMonitorGroupSlotIndex INTEGER
  chipRptrMonitorGroupNetID INTEGER
  chipRptrMonitorGroupIndex INTEGER
  chipRptrMonitorGroupTotalFrames Counter
  chipRptrMonitorGroupTotalOctets Counter
  chipRptrMonitorGroupTotalErrors Counter

ChipRptrMonitorPortEntry  
SEQUENCE    
  chipRptrMonitorPortSlotIndex INTEGER
  chipRptrMonitorPortNetID INTEGER
  chipRptrMonitorPortGroupIndex INTEGER
  chipRptrMonitorPortIndex INTEGER
  chipRptrMonitorPortReadableFrames Counter
  chipRptrMonitorPortReadableOctets Counter
  chipRptrMonitorPortFCSErrors Counter
  chipRptrMonitorPortAlignmentErrors Counter
  chipRptrMonitorPortFrameTooLongs Counter
  chipRptrMonitorPortShortEvents Counter
  chipRptrMonitorPortRunts Counter
  chipRptrMonitorPortCollisions Counter
  chipRptrMonitorPortLateEvents Counter
  chipRptrMonitorPortVeryLongEvents Counter
  chipRptrMonitorPortDataRateMismatches Counter
  chipRptrMonitorPortAutoPartitions Counter
  chipRptrMonitorPortTotalErrors Counter

ChipRptrAddrTrackEntry  
SEQUENCE    
  chipRptrAddrTrackSlotIndex INTEGER
  chipRptrAddrTrackGroupNetID INTEGER
  chipRptrAddrTrackGroupIndex INTEGER
  chipRptrAddrTrackPortIndex INTEGER
  chipRptrAddrTrackLastSourceAddress MacAddress
  chipRptrAddrTrackSourceAddrChanges Counter
  chipRptrAddrTrackNewLastSrcAddress OCTET STRING

OlTRnetStatsEntry  
SEQUENCE    
  olTRnetStatsNetID INTEGER
  olTRnetStatsLineErrors Counter
  olTRnetStatsBurstErrors Counter
  olTRnetStatsACErrors Counter
  olTRnetStatsLostFrameErrors Counter
  olTRnetStatsCongestionErrors Counter
  olTRnetStatsFrameCopiedErrors Counter
  olTRnetStatsTokenErrors Counter
  olTRnetStatsDuplicateAddresses Counter
  olTRnetStatsBeaconEvents Counter
  olTRnetStatsLastBeaconSender OCTET STRING
  olTRnetStatsLastBeaconNAUN OCTET STRING
  olTRnetStatsLastBeaconTime TimeTicks
  olTRnetStatsLastBeaconAction INTEGER
  olTRnetStatsTotalStations INTEGER
  olTRnetStatsConcStations INTEGER
  olTRnetStatsTotalPorts INTEGER
  olTRnetStatsEnabledPorts INTEGER
  olTRnetStatsActivePorts INTEGER

OlTRnetStatsStationEntry  
SEQUENCE    
  olTRnetStatsStationNetID INTEGER
  olTRnetStatsStationAddr OCTET STRING
  olTRnetStatsStationSlotIndex INTEGER
  olTRnetStatsStationPortIndex INTEGER
  olTRnetStatsStationNAUNAddress OCTET STRING
  olTRnetStatsStationLineErrors Counter
  olTRnetStatsStationBurstErrors Counter
  olTRnetStatsStationACErrors Counter
  olTRnetStatsStationLostFrameErrors Counter
  olTRnetStatsStationCongestionErrors Counter
  olTRnetStatsStationFrameCopiedErrors Counter
  olTRnetStatsStationTokenErrors Counter
  olTRnetStatsStationDuplicateAddresses Counter

OlTRnetStatsPortEntry  
SEQUENCE    
  olTRnetStatsPortSlotIndex INTEGER
  olTRnetStatsPortIndex INTEGER
  olTRnetStatsPortNetID INTEGER
  olTRnetStatsPortTotalStations INTEGER
  olTRnetStatsPortAddress OCTET STRING
  olTRnetStatsPortLineErrors Counter
  olTRnetStatsPortBurstErrors Counter
  olTRnetStatsPortACErrors Counter
  olTRnetStatsPortLostFrameErrors Counter
  olTRnetStatsPortCongestionErrors Counter
  olTRnetStatsPortFrameCopiedErrors Counter
  olTRnetStatsPortTokenErrors Counter
  olTRnetStatsPortDuplicateAddresses Counter

OlTRnetMapSummaryEntry  
SEQUENCE    
  olTRnetMapSummaryNetID INTEGER
  olTRnetMapSummaryIndex INTEGER
  olTRnetMapSummary32Stations OCTET STRING

OlTRTrafEntry  
SEQUENCE    
  olTRTrafNetID INTEGER
  olTRTrafTokenRotationTime INTEGER
  olTRTrafDropEvents Counter
  olTRTrafOctets Counter
  olTRTrafFrames Counter
  olTRTrafMacOctets Counter
  olTRTrafMacFrames Counter
  olTRTrafBroadcastFrames Counter
  olTRTrafMulticastFrames Counter
  olTRTrafFrames18to63Octets Counter
  olTRTrafFrames64to127Octets Counter
  olTRTrafFrames128to255Octets Counter
  olTRTrafFrames256to511Octets Counter
  olTRTrafFrames512to1023Octets Counter
  olTRTrafFrames1024to2047Octets Counter
  olTRTrafFrames2048to4095Octets Counter
  olTRTrafFrames4096to8191Octets Counter
  olTRTrafFrames8192to18000Octets Counter
  olTRTrafFramesGreaterThan18000Octets Counter

OlTRTrafControlEntry  
SEQUENCE    
  olTRTrafControlNetID INTEGER
  olTRTrafControlLogicalState INTEGER
  olTRTrafControlLogicalLock INTEGER
  olTRTrafControlClear INTEGER
  olTRTrafControlLastClearTime TimeTicks
  olTRTrafControlTotalStations INTEGER
  olTRTrafControlStationLastChangeTime TimeTicks
  olTRTrafControlPortTotalStations INTEGER
  olTRTrafControlPortLastChangeTime TimeTicks
  olTRTrafControlTopNMaxStations INTEGER
  olTRTrafControlTopNTotalStations INTEGER
  olTRTrafControlTopNLastChangeTime TimeTicks
  olTRTrafControlTopNInterval INTEGER

OlTRTrafStationEntry  
SEQUENCE    
  olTRTrafStationNetID INTEGER
  olTRTrafStationAddress MacAddress
  olTRTrafStationSlotIndex INTEGER
  olTRTrafStationPortIndex INTEGER
  olTRTrafStationInFrames Counter
  olTRTrafStationOutFrames Counter
  olTRTrafStationInOctets Counter
  olTRTrafStationOutOctets Counter
  olTRTrafStationOutErrors Counter
  olTRTrafStationOutBroadcastFrames Counter
  olTRTrafStationOutMulticastFrames Counter

OlTRTrafPortEntry  
SEQUENCE    
  olTRTrafPortSlotIndex INTEGER
  olTRTrafPortPortIndex INTEGER
  olTRTrafPortNetID INTEGER
  olTRTrafPortAddress MacAddress
  olTRTrafPortInFrames Counter
  olTRTrafPortOutFrames Counter
  olTRTrafPortInOctets Counter
  olTRTrafPortOutOctets Counter
  olTRTrafPortOutErrors Counter
  olTRTrafPortOutBroadcastFrames Counter
  olTRTrafPortOutMulticastFrames Counter

OlTRTrafTopNEntry  
SEQUENCE    
  olTRTrafTopNNetID INTEGER
  olTRTrafTopNStatistic INTEGER
  olTRTrafTopNIndex INTEGER
  olTRTrafTopNAddress MacAddress
  olTRTrafTopNSlotIndex INTEGER
  olTRTrafTopNPortIndex INTEGER
  olTRTrafTopNInFrames Counter
  olTRTrafTopNOutFrames Counter
  olTRTrafTopNInOctets Counter
  olTRTrafTopNOutOctets Counter
  olTRTrafTopNOutErrors Counter
  olTRTrafTopNOutBroadcastFrames Counter
  olTRTrafTopNOutMulticastFrames Counter

OlTRTrafTopNSummaryEntry  
SEQUENCE    
  olTRTrafTopNSummaryNetID INTEGER
  olTRTrafTopNSummaryStatistic INTEGER
  olTRTrafTopNSummaryIndex INTEGER
  olTRTrafTopNSummaryStations OCTET STRING

OlFDDIStatsModEntry  
SEQUENCE    
  olFDDIStatsModSlotIndex INTEGER
  olFDDIStatsModMgtRcvErrs Counter
  olFDDIStatsModMgtXmitErrs Counter
  olFDDIStatsModBackplaneErrs Counter
  olFDDIStatsModPllUnlockErrs Counter

OlFDDIStatsPortEntry  
SEQUENCE    
  olFDDIStatsPortSlotIndex INTEGER
  olFDDIStatsPortIndex INTEGER
  olFDDIStatsPortLCTFailCts Counter
  olFDDIStatsPortLerEstimate INTEGER
  olFDDIStatsPortLemRejectCts Counter
  olFDDIStatsPortLemCts Counter

OlFDDInetStatsEntry  
SEQUENCE    
  olFDDInetStatsNetID INTEGER
  olFDDInetStatsRingOpCounts Counter
  olFDDInetStatsFrameCounts Counter
  olFDDInetStatsErrorCounts Counter
  olFDDInetStatsLostCounts Counter
  olFDDInetStatsFrameErrorRatio INTEGER

OlGroupPortEntry  
SEQUENCE    
  olGroupPortSlotIndex INTEGER
  olGroupPortIndex INTEGER
  olGroupPortGroupID OCTET STRING

OlGroupSummaryEntry  
SEQUENCE    
  olGroupSummaryGroupID INTEGER
  olGroupSummaryIndex INTEGER
  olGroupSummaryPorts OCTET STRING

OlThreshEntry  
SEQUENCE    
  olThreshIndex INTEGER
  olThreshMode INTEGER
  olThreshDescription DisplayString
  olThreshObjectIdentifier OBJECT IDENTIFIER
  olThreshStatCategory INTEGER
  olThreshStatType INTEGER
  olThreshStatNetID INTEGER
  olThreshStatSlotIndex INTEGER
  olThreshStatPortIndex INTEGER
  olThreshStatStationAddr MacAddress
  olThreshInterval INTEGER
  olThreshCondition INTEGER
  olThreshValue INTEGER
  olThreshCurrentValue INTEGER
  olThreshStatus INTEGER
  olThreshTimeSinceLastTriggered TimeTicks
  olThreshActionType INTEGER
  olThreshActionData INTEGER
  olThreshActionPriority INTEGER

OcPowerOutputEntry  
SEQUENCE    
  ocPowerOutputType INTEGER
  ocPowerOutputVoltageLevel Gauge
  ocPowerOutputWattageCapacity Gauge
  ocPowerOutputWattageConsumed Gauge
  ocPowerOutputWattageAvailable Gauge
  ocPowerOutputUnmanagedWattageAlloc Gauge

OcPowerSlotEntry  
SEQUENCE    
  ocPowerSlotIndex INTEGER
  ocPowerSlotClass INTEGER
  ocPowerSlotAdminStatus INTEGER
  ocPowerSlotOperStatus INTEGER

OcInvModEntry  
SEQUENCE    
  ocInvModSlotIndex INTEGER
  ocInvModSubSlotIndex INTEGER
  ocInvModModel DisplayString
  ocInvModSerialNo DisplayString
  ocInvModHWVer DisplayString
  ocInvModSWVer DisplayString
  ocInvModSWBootVer DisplayString
  ocInvModMfr DisplayString
  ocInvModMfrDate DisplayString

OlPS2McaEntry  
SEQUENCE    
  olPS2McaIndex INTEGER
  olPS2McaDescription DisplayString
  olPS2McaSlotConnectPoint INTEGER
  olPS2McaPortConnectPoint INTEGER
  olPS2McaMacAddress OCTET STRING

OlPS2ApplEntry  
SEQUENCE    
  olPS2ApplIndex INTEGER
  olPS2ApplDescription DisplayString

ExpDot5Entry  
SEQUENCE    
  expDot5IfIndex INTEGER
  expDot5Commands INTEGER
  expDot5RingStatus INTEGER
  expDot5RingState INTEGER
  expDot5RingOpenStatus INTEGER
  expDot5RingSpeed INTEGER
  expDot5UpStream MacAddress
  expDot5ActMonParticipate INTEGER
  expDot5Functional MacAddress

ExpDot5StatsEntry  
SEQUENCE    
  expDot5StatsIfIndex INTEGER
  expDot5StatsLineErrors Counter
  expDot5StatsBurstErrors Counter
  expDot5StatsACErrors Counter
  expDot5StatsAbortTransErrors Counter
  expDot5StatsInternalErrors Counter
  expDot5StatsLostFrameErrors Counter
  expDot5StatsReceiveCongestions Counter
  expDot5StatsFrameCopiedErrors Counter
  expDot5StatsTokenErrors Counter
  expDot5StatsSoftErrors Counter
  expDot5StatsHardErrors Counter
  expDot5StatsSignalLoss Counter
  expDot5StatsTransmitBeacons Counter
  expDot5StatsRecoverys Counter
  expDot5StatsLobeWires Counter
  expDot5StatsRemoves Counter
  expDot5StatsSingles Counter
  expDot5StatsFreqErrors Counter

ExpDot5TimerEntry  
SEQUENCE    
  expDot5TimerIfIndex INTEGER
  expDot5TimerReturnRepeat INTEGER
  expDot5TimerHolding INTEGER
  expDot5TimerQueuePDU INTEGER
  expDot5TimerValidTransmit INTEGER
  expDot5TimerNoToken INTEGER
  expDot5TimerActiveMon INTEGER
  expDot5TimerStandbyMon INTEGER
  expDot5TimerErrorReport INTEGER
  expDot5TimerBeaconTransmit INTEGER
  expDot5TimerBeaconReceive INTEGER

ChipTTYEntry  
SEQUENCE    
  chipTTYIndex INTEGER
  chipTTYBaud INTEGER
  chipTTYParity INTEGER
  chipTTYStop INTEGER
  chipTTYData INTEGER
  chipTTYTimeout INTEGER
  chipTTYPrompt DisplayString
  chipTTYDTR INTEGER
  chipTTYTerminalType DisplayString

ChipAlertEntry  
SEQUENCE    
  chipAlertIndex INTEGER
  chipAlertMode INTEGER

Defined Values

chipcom 1.3.6.1.4.1.49
OBJECT IDENTIFIER    

chipmib02 1.3.6.1.4.1.49.2
OBJECT IDENTIFIER    

chipGen 1.3.6.1.4.1.49.2.1
OBJECT IDENTIFIER    

chipEcho 1.3.6.1.4.1.49.2.2
OBJECT IDENTIFIER    

chipProducts 1.3.6.1.4.1.49.2.3
OBJECT IDENTIFIER    

chipExperiment 1.3.6.1.4.1.49.2.4
OBJECT IDENTIFIER    

chipTTY 1.3.6.1.4.1.49.2.5
OBJECT IDENTIFIER    

chipTFTP 1.3.6.1.4.1.49.2.6
OBJECT IDENTIFIER    

chipDownload 1.3.6.1.4.1.49.2.7
OBJECT IDENTIFIER    

chipAlert 1.3.6.1.4.1.49.2.8
OBJECT IDENTIFIER    

chipBootP 1.3.6.1.4.1.49.2.11
OBJECT IDENTIFIER    

online 1.3.6.1.4.1.49.2.3.1
OBJECT IDENTIFIER    

oebm 1.3.6.1.4.1.49.2.3.2
OBJECT IDENTIFIER    

midnight 1.3.6.1.4.1.49.2.3.3
OBJECT IDENTIFIER    

workGroupHub 1.3.6.1.4.1.49.2.3.4
OBJECT IDENTIFIER    

emm 1.3.6.1.4.1.49.2.3.5
OBJECT IDENTIFIER    

chipBridge 1.3.6.1.4.1.49.2.3.6
OBJECT IDENTIFIER    

trmm 1.3.6.1.4.1.49.2.3.7
OBJECT IDENTIFIER    

fmm 1.3.6.1.4.1.49.2.3.8
OBJECT IDENTIFIER    

focus1 1.3.6.1.4.1.49.2.3.9
OBJECT IDENTIFIER    

oeim 1.3.6.1.4.1.49.2.3.10
OBJECT IDENTIFIER    

oncore 1.3.6.1.4.1.49.2.3.11
OBJECT IDENTIFIER    

dmm 1.3.6.1.4.1.49.2.3.12
OBJECT IDENTIFIER    

onsembleEthernet 1.3.6.1.4.1.49.2.3.13
OBJECT IDENTIFIER    

chipExpTokenRing 1.3.6.1.4.1.49.2.4.1
OBJECT IDENTIFIER    

dot1dBridge 1.3.6.1.4.1.49.2.4.14
OBJECT IDENTIFIER    

expDot5 1.3.6.1.4.1.49.2.4.1.1
OBJECT IDENTIFIER    

olAgents 1.3.6.1.4.1.49.2.3.1.1
OBJECT IDENTIFIER    

olConc 1.3.6.1.4.1.49.2.3.1.2
OBJECT IDENTIFIER    

olEnv 1.3.6.1.4.1.49.2.3.1.3
OBJECT IDENTIFIER    

olModules 1.3.6.1.4.1.49.2.3.1.4
OBJECT IDENTIFIER    

olNets 1.3.6.1.4.1.49.2.3.1.5
OBJECT IDENTIFIER    

olGroups 1.3.6.1.4.1.49.2.3.1.6
OBJECT IDENTIFIER    

olAlarm 1.3.6.1.4.1.49.2.3.1.7
OBJECT IDENTIFIER    

ocPower 1.3.6.1.4.1.49.2.3.1.8
OBJECT IDENTIFIER    

ocPowerControl 1.3.6.1.4.1.49.2.3.1.8.1
OBJECT IDENTIFIER    

ocInventory 1.3.6.1.4.1.49.2.3.1.9
OBJECT IDENTIFIER    

ocInvHub 1.3.6.1.4.1.49.2.3.1.9.1
OBJECT IDENTIFIER    

ocInvMods 1.3.6.1.4.1.49.2.3.1.9.2
OBJECT IDENTIFIER    

olPS2 1.3.6.1.4.1.49.2.3.1.11
OBJECT IDENTIFIER    

olSpecMods 1.3.6.1.4.1.49.2.3.1.4.4
OBJECT IDENTIFIER    

ol50nnMCTL 1.3.6.1.4.1.49.2.3.1.4.4.3
OBJECT IDENTIFIER    

ol51nnMMGT 1.3.6.1.4.1.49.2.3.1.4.4.4
OBJECT IDENTIFIER    

ol51nnMFIB 1.3.6.1.4.1.49.2.3.1.4.4.5
OBJECT IDENTIFIER    

ol51nnMUTP 1.3.6.1.4.1.49.2.3.1.4.4.6
OBJECT IDENTIFIER    

ol51nnMTP 1.3.6.1.4.1.49.2.3.1.4.4.7
OBJECT IDENTIFIER    

ol51nnMBNC 1.3.6.1.4.1.49.2.3.1.4.4.8
OBJECT IDENTIFIER    

ol51nnBEE 1.3.6.1.4.1.49.2.3.1.4.4.9
OBJECT IDENTIFIER    

ol51nnRES 1.3.6.1.4.1.49.2.3.1.4.4.10
OBJECT IDENTIFIER    

ol51nnREE 1.3.6.1.4.1.49.2.3.1.4.4.11
OBJECT IDENTIFIER    

ol51nnMAUIF 1.3.6.1.4.1.49.2.3.1.4.4.12
OBJECT IDENTIFIER    

ol51nnMAUIM 1.3.6.1.4.1.49.2.3.1.4.4.13
OBJECT IDENTIFIER    

ol5208MTP 1.3.6.1.4.1.49.2.3.1.4.4.14
OBJECT IDENTIFIER    

ol51nnMFP 1.3.6.1.4.1.49.2.3.1.4.4.15
OBJECT IDENTIFIER    

ol51nnMFBP 1.3.6.1.4.1.49.2.3.1.4.4.16
OBJECT IDENTIFIER    

ol51nnMTPL 1.3.6.1.4.1.49.2.3.1.4.4.17
OBJECT IDENTIFIER    

ol51nnMTPPL 1.3.6.1.4.1.49.2.3.1.4.4.18
OBJECT IDENTIFIER    

ol52nnMTP 1.3.6.1.4.1.49.2.3.1.4.4.19
OBJECT IDENTIFIER    

ol52nnMFR 1.3.6.1.4.1.49.2.3.1.4.4.20
OBJECT IDENTIFIER    

ol51nnMTS 1.3.6.1.4.1.49.2.3.1.4.4.21
OBJECT IDENTIFIER    

ol51nnMFL 1.3.6.1.4.1.49.2.3.1.4.4.22
OBJECT IDENTIFIER    

ol50nnMRCTL 1.3.6.1.4.1.49.2.3.1.4.4.23
OBJECT IDENTIFIER    

ol51nnMFB 1.3.6.1.4.1.49.2.3.1.4.4.24
OBJECT IDENTIFIER    

ol53nnMMGT 1.3.6.1.4.1.49.2.3.1.4.4.25
OBJECT IDENTIFIER    

ol53nnMFBMIC 1.3.6.1.4.1.49.2.3.1.4.4.26
OBJECT IDENTIFIER    

ol53nnMFIBST 1.3.6.1.4.1.49.2.3.1.4.4.27
OBJECT IDENTIFIER    

ol53nnMSTP 1.3.6.1.4.1.49.2.3.1.4.4.28
OBJECT IDENTIFIER    

ol51nnMTPCL 1.3.6.1.4.1.49.2.3.1.4.4.29
OBJECT IDENTIFIER    

ol52nnBTT 1.3.6.1.4.1.49.2.3.1.4.4.30
OBJECT IDENTIFIER    

ol51nnIx 1.3.6.1.4.1.49.2.3.1.4.4.31
OBJECT IDENTIFIER    

ol52nnMMGT 1.3.6.1.4.1.49.2.3.1.4.4.32
OBJECT IDENTIFIER    

ol50nnMHCTL 1.3.6.1.4.1.49.2.3.1.4.4.33
OBJECT IDENTIFIER    

oc61nnMCAR 1.3.6.1.4.1.49.2.3.1.4.4.35
OBJECT IDENTIFIER    

oc60nnMMGT 1.3.6.1.4.1.49.2.3.1.4.4.43
OBJECT IDENTIFIER    

oc61nnDMGT 1.3.6.1.4.1.49.2.3.1.4.4.45
OBJECT IDENTIFIER    

oc61nnMFBP 1.3.6.1.4.1.49.2.3.1.4.4.46
OBJECT IDENTIFIER    

oc61nnMTPL 1.3.6.1.4.1.49.2.3.1.4.4.47
OBJECT IDENTIFIER    

ol51nnMTPLS 1.3.6.1.4.1.49.2.3.1.4.4.48
OBJECT IDENTIFIER    

oc60nnMRCTL 1.3.6.1.4.1.49.2.3.1.4.4.50
OBJECT IDENTIFIER    

ol50nnMRCLS 1.3.6.1.4.1.49.2.3.1.4.4.51
OBJECT IDENTIFIER    

ol41nnHMTP 1.3.6.1.4.1.49.2.3.1.4.4.52
OBJECT IDENTIFIER    

ol41nnHETP 1.3.6.1.4.1.49.2.3.1.4.4.53
OBJECT IDENTIFIER    

ol52nnMEC 1.3.6.1.4.1.49.2.3.1.4.4.62
OBJECT IDENTIFIER    

ol53nnMTDDI 1.3.6.1.4.1.49.2.3.1.4.4.65
OBJECT IDENTIFIER    

olNet 1.3.6.1.4.1.49.2.3.1.5.1
OBJECT IDENTIFIER    

olEnet 1.3.6.1.4.1.49.2.3.1.5.2
OBJECT IDENTIFIER    

olTRnet 1.3.6.1.4.1.49.2.3.1.5.3
OBJECT IDENTIFIER    

olFDDInet 1.3.6.1.4.1.49.2.3.1.5.4
OBJECT IDENTIFIER    

hubSysGroup 1.3.6.1.4.1.49.2.3.4.1
OBJECT IDENTIFIER    

hardwareGroup 1.3.6.1.4.1.49.2.3.4.2
OBJECT IDENTIFIER    

softwareGroup 1.3.6.1.4.1.49.2.3.4.3
OBJECT IDENTIFIER    

hubGroup 1.3.6.1.4.1.49.2.3.4.4
OBJECT IDENTIFIER    

boardGroup 1.3.6.1.4.1.49.2.3.4.5
OBJECT IDENTIFIER    

portGroup 1.3.6.1.4.1.49.2.3.4.6
OBJECT IDENTIFIER    

alarmGroup 1.3.6.1.4.1.49.2.3.4.7
OBJECT IDENTIFIER    

olThresh 1.3.6.1.4.1.49.2.3.1.7.1
OBJECT IDENTIFIER    

olThreshControl 1.3.6.1.4.1.49.2.3.1.7.1.1
OBJECT IDENTIFIER    

chipGenProduct 1.3.6.1.4.1.49.2.1.1
The product type represented by this agent.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER product-5100M-MGT(1), product-5102B-EE(2), product-8383B(3), product-5112H-UTP(4), product-5300M-MGT(5), product-5200M-MGT(7), product-4112H-MTP(8), product-6100M-MGT(12)  

chipGenServiceDate 1.3.6.1.4.1.49.2.1.2
The date that the product was last serviced in the format yymmdd. If this date is unknown, the value of this object is '000000'.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(6)  

chipGenNetman 1.3.6.1.4.1.49.2.1.3
The IP (source) Address of the last authenticated SNMP PDU received by this entity before this request. An IP Address of 00.00.00.00 represents the default value.
Status: mandatory Access: read-only
OBJECT-TYPE    
  IpAddress  

chipGenDiagnostics 1.3.6.1.4.1.49.2.1.4
The result of this product's diagnostic test(s). If any test fails, this will have the failed(2) value. Note, many products do not operate after a diagnostic failure. In this case, no SNMP communication would be available.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER passed(1), failed(2)  

chipGenSerial 1.3.6.1.4.1.49.2.1.5
The serial number of this product.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(1..128)  

chipGenID 1.3.6.1.4.1.49.2.1.6
A unique ID used for grouping disparate agents together. For example, a concentrator may contain multiple agents. This ID is could be assigned by the management station to identify all of these agents as being contained in the same concentrator.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

chipGenVers 1.3.6.1.4.1.49.2.1.7
The version identifier(s) for this agent.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

chipGenAuthFailureAddr 1.3.6.1.4.1.49.2.1.8
The source IP Address of the last SNMP request that caused an authentication failure trap to be generated. This object is also included in the SNMP authenticationFailure trap.
Status: mandatory Access: read-only
OBJECT-TYPE    
  IpAddress  

chipGenTimeLastChanged 1.3.6.1.4.1.49.2.1.9
A snapshot of sysUpTime when the last trap was generated. This attribute can be used to save polling by a management station. If there have been no traps generated since the last poll, there is no need for the station to poll again.
Status: mandatory Access: read-only
OBJECT-TYPE    
  TimeTicks  

chipEchoStart 1.3.6.1.4.1.49.2.2.1
Setting chipEchoStart to startEcho(2) causes the device to begin an ICMP echo sequence using the parameters indicated by the rest of the chipEcho group.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER noEcho(1), startEcho(2)  

chipEchoAddr 1.3.6.1.4.1.49.2.2.2
The IP Address to which the device will ping. This object can only be set to valid unicast class A, class B, or class C addresses. The default IP Address is loopback (127.0.0.1).
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

chipEchoPattern 1.3.6.1.4.1.49.2.2.3
The actual pattern to be contained in the ICMP echo packet.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER zeroes(1), ones(2), mixed(3)  

chipEchoNumber 1.3.6.1.4.1.49.2.2.4
The number of ICMP echo packets (pings) to send.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..255  

chipEchoSize 1.3.6.1.4.1.49.2.2.5
The size of the ICMP echo packet (ping) to send when chipEchoStart is set. The valid range is between 64 and 1500 octets.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 64..1500  

chipEchoResponseCounts 1.3.6.1.4.1.49.2.2.6
The count of ICMP echo response packets received since the last PING was initiated.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

olAgentsMySlot 1.3.6.1.4.1.49.2.3.1.1.1
The slot id of this agent.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

olAgentsMasterReset 1.3.6.1.4.1.49.2.3.1.1.2
Resetting mastership causes a new mastership election to occur. The agent with the highest mastership priority will become the new master. If there is more than one agent with the highest priority, the selection between those agents will be arbritrary.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER noReset(1), reset(2)  

olAgentsTable 1.3.6.1.4.1.49.2.3.1.1.3
A table of agents in the concentrator as seen by this agent. A master will see all the agents; a slave will only see itself.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    OlAgentsEntry

olAgentsEntry 1.3.6.1.4.1.49.2.3.1.1.3.1
A profile of an agent within the concentrator.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  OlAgentsEntry  

olAgentsSlotIndex 1.3.6.1.4.1.49.2.3.1.1.3.1.1
The slot number that identifies the referenced agent.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

olAgentsStationAddr 1.3.6.1.4.1.49.2.3.1.1.3.1.2
The unique identifier for this agent. Often this is the value of ifPhysAddress for the first interface.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(6)  

olAgentsIpAddress 1.3.6.1.4.1.49.2.3.1.1.3.1.3
An IP Address that can be used to communicate to this agent. Note, this object's value may change as the agent switches to different sub-networks.
Status: mandatory Access: read-only
OBJECT-TYPE    
  IpAddress  

olAgentsMasterStatus 1.3.6.1.4.1.49.2.3.1.1.3.1.4
The mastership status of this agent.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER master(1), non-master(2), electing(3)  

olAgentsMasterPriority 1.3.6.1.4.1.49.2.3.1.1.3.1.5
The mastership priority of this agent. Ten is the highest and one is the lowest. Never means will not be able become master. Some agents do not have the capability to become master (the etherent to ethernet bridge, e.g.) and setting those agents to a value other than never(11) will generate an invalid value error. Priority is only used when an election occurs. Mastership is not pre-emptive; use the reset mastership command (olAgentsMasterReset).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER one(1), two(2), three(3), four(4), five(5), six(6), seven(7), eight(8), nine(9), ten(10), never(11)  

ocAgentsSubSlot 1.3.6.1.4.1.49.2.3.1.1.3.1.6
The subslot index for this agent. For agents not located in the ONcore system, this object will always return 1 for this object value.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

olConcType 1.3.6.1.4.1.49.2.3.1.2.1
This object identifies the type of concentrator represented by this agent.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hub-5017C(1), hub-5006C(2), hub-5006C-FT(3), hub-5006C-HC(4), hub-5006C-HC-FT(5), hub-6017C-A(6), hub-4112-HMTP(7), hub-5017C-LS(9)  

olConcReset 1.3.6.1.4.1.49.2.3.1.2.2
Setting this value to reset(2) causes this concentrator to reset.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER noReset(1), reset(2)  

olConcNumSlots 1.3.6.1.4.1.49.2.3.1.2.3
The number of slots in this concentrator. This value is the sum total of all payload slots plus any slots reserved for controller modules. For example, for an ONcore agent operating in a 17-slot ONcore hub, this object will have the value 19 (17 payload slots plus 2 controller slots). Similarly, if an ONline hub contains a hidden controller, then this object will have the value 7 (the hidden controller does not actually occupy a main slot in the 6-slot concentrator, but it will report itself as slot 7). Also, for an ONline agent operating in an ONcore hub, this object's value will not exceed 17.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

olConcProfile 1.3.6.1.4.1.49.2.3.1.2.4
A bit string where the least significant bit corresponds to slot 1. A '1' in the bit indicates that a module is present in that slot. The number of octets provided is based on the olConcNumSlots value divided by 8. Any extra bits (for example, bits 18-24 for 17 slots) are meaningless. For example, the string 0x01 0xFF 0xFF would represent a full 17 slot concentrator.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(1..3)  

olEnvTempStatus 1.3.6.1.4.1.49.2.3.1.3.1
The overall temperature status for this concentrator. This object's value is an aggregate of all the temperature probes in the concentrator, such that, when at least one probe reports extreme temperature, this object will have the value extremeTemp(2). This object will have the value warning(3) prior to reporting the value extremeTemp(2) as a means of warning of a possible hub overheat condition.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER okay(1), extremeTemp(2), warning(3)  

olEnvPSCapacity 1.3.6.1.4.1.49.2.3.1.3.2
The total capacity of power supplies for this concentrator.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

olEnvPSTable 1.3.6.1.4.1.49.2.3.1.3.3
A table that contains information about each potential power supply in the concentrator.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    OlEnvPSEntry

olEnvPSEntry 1.3.6.1.4.1.49.2.3.1.3.3.1
A list of information for each power supply in the concentrator.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  OlEnvPSEntry  

olEnvPSIndex 1.3.6.1.4.1.49.2.3.1.3.3.1.1
Identifies the power supply for which this entry contains power supply information. For systems with the primary and backup power supply (as opposed to the N+1 design), index 1 refers to the primary, and index 2 refers to the backup.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

olEnvPSAdminState 1.3.6.1.4.1.49.2.3.1.3.3.1.2
The current desired state of the power supply. A power supply in standby does not provide power to the concentrator. Note, in a Load Sharing Hub, this object is read only.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER activate(1), standby(2)  

olEnvPSOperStatus 1.3.6.1.4.1.49.2.3.1.3.3.1.3
The current operational state of the power supply. A power supply in standby does not provide power to the concentrator.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER active(1), standby(2), faulty(3), not-installed(4)  

olEnvFanStatus 1.3.6.1.4.1.49.2.3.1.3.4
The overall status of the fan(s). When fan operational status is known, this object's value is an aggregate of all fan status in the concentrator such that, when at least one fan unit is faulty, this object will have the value faulty(2).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER okay(1), faulty(2), not-installed(4), unknown(5)  

olEnvTable 1.3.6.1.4.1.49.2.3.1.3.5
A table that contains information about the concentrator environment.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    OlEnvEntry

olEnvEntry 1.3.6.1.4.1.49.2.3.1.3.5.1
A list of information for each monitored component in this concentrator.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  OlEnvEntry  

olEnvType 1.3.6.1.4.1.49.2.3.1.3.5.1.1
The type of hardware component monitored in this concentrator.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ls-pdb(1)  

olEnvStatus 1.3.6.1.4.1.49.2.3.1.3.5.1.2
The status of the monitored hardware component.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER okay(1), faulty(2)  

olModTable 1.3.6.1.4.1.49.2.3.1.4.1
A table that contains generic information about every module that is present within the concentrator. If the concentrator is the ONcore Hub, then only the motherboard is present in this table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    OlModEntry

olModEntry 1.3.6.1.4.1.49.2.3.1.4.1.1
A list of information for each module in the concentrator. If the concentrator is the ONcore Hub, then only the motherboard is present in this table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  OlModEntry  

olModSlotIndex 1.3.6.1.4.1.49.2.3.1.4.1.1.1
The unique slot number of this module. Its value ranges between 1 and olConcNumSlots and remains constant at least from one re-initialization of the entity's network management system to the next re-initialization.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

olModType 1.3.6.1.4.1.49.2.3.1.4.1.1.2
The unique type identifier for this module. This type is used to identify the branch in olSpecMods (see below). module-unmanageable(1) means that only the following objects are valid for this module: olModSlotIndex olModClass olModVersion olModVendor olModReset olModConfigToDips olModConfigured module-unknown(2) means that all the generic attributes are manageable, but there is no olSpecMods branch for this module as viewed by this agent.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER module-unmanageable(1), module-unknown(2), module-50nnM-CTL(3), module-51nnM-MGT(4), module-51nnM-FIB(5), module-51nnM-UTP(6), module-51nnM-TP(7), module-51nnM-BNC(8), module-51nnB-EE(9), module-51nnR-ES(10), module-51nnR-EE(11), module-51nnM-AUIF(12), module-51nnM-AUIM(13), module-5208M-TP(14), module-51nnM-FP(15), module-51nnM-FBP(16), module-51nnM-TPL(17), module-51nnM-TPPL(18), module-52nnM-TP(19), module-52nnM-FR(20), module-51nnM-TS(21), module-51nnM-FL(22), module-50nnM-RCTL(23), module-51nnM-FB(24), module-53nnM-MGT(25), module-53nnM-FBMIC(26), module-53nnM-FIBST(27), module-53nnM-STP(28), module-51nnM-TPCL(29), module-52nnB-TT(30), module-51nnI-x(31), module-52nnM-MGT(32), module-50nnM-HCTL(33), module-61nnM-CAR(35), module-60nnM-MGT(43), module-61nnD-MGT(45), module-61nnM-FBP(46), module-61nnM-TPL(47), module-51nnM-TPLS(48), module-60nnM-RCTL(50), module-50nnM-RCLS(51), module-41nnH-MTP(52), module-41nnH-ETP(53), module-52nnM-EC(62), module-53nnM-TDDI(65)  

olModClass 1.3.6.1.4.1.49.2.3.1.4.1.1.3
The class of this module. Generally speaking, this object indicates the kind of module. Specifically, the class identifier specifies the internal representation of the module's managed information base.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER controller(1), mgmt(2), ethernet-media(3), ethernet-interconnect(4), ethernet-portswitching-media(5), token-ring-media(6), terminal-server(7), fddi-media(8), token-ring-mgmt(9), ethernet-connswitching-media(10), token-ring-interconnect(11), fddi-mgmt(12), oncore-token-ring-media(13), ethernet-carrier(14), oncore-oem-specials(15), oncore-download(17), ethernet-media-extended(19), online-token-ring-mod-interconnect(20)  

olModDescr 1.3.6.1.4.1.49.2.3.1.4.1.1.4
A textual string containing information about the module.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(1..128)  

olModVersion 1.3.6.1.4.1.49.2.3.1.4.1.1.5
The software version number of this module.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(1..32)  

olModVendor 1.3.6.1.4.1.49.2.3.1.4.1.1.6
The actual manufacturer of this board.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER chipcom(1), cisco(2), pilkington(3), datability(5), ibm(6), raycom(7), retix(8), intellicom(9)  

olModResetModule 1.3.6.1.4.1.49.2.3.1.4.1.1.7
Setting this object to reset(2) causes this module to reset.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER noReset(1), reset(2)  

olModConfigToDips 1.3.6.1.4.1.49.2.3.1.4.1.1.8
Setting this object to configure(2) causes this module to configure based on the dip switch settings.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER noConfigure(1), configure(2)  

olModConfigured 1.3.6.1.4.1.49.2.3.1.4.1.1.9
This object indicates whether this module has already been configured. An unconfigured module is configured to a safe state where the network is isolated and the ports are disabled.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER notConfigured(1), configured(2)  

olModNetwork 1.3.6.1.4.1.49.2.3.1.4.1.1.10
The network that this module is attached to. If the value is other(1) or port-switching(3), setting this object to a different value will generate the invalidData error. If the value is port-switching(3), manage the networks via the olPortNetwork object. The value per-connector(20) is returned if the managed module is a per-connector switchable and the connectors are on different networks. The connector networks are managed by the objects defined in the olSpecMods branch specified for this module. Modules and ports on the same network intercommunicate. Setting the module to isolated(2) (or other isolated values), removes this module from the backplane. Setting this module to a value that is not the same protocol type will return an invalidData error. Setting this module to a value that it does not support will return an invalidData error.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER other(1), isolated(2), port-switching(3), front-panel(5), ethernet-1(6), ethernet-2(7), ethernet-3(8), token-ring-1(9), token-ring-2(10), token-ring-3(11), token-ring-4(12), token-ring-5(13), token-ring-6(14), token-ring-7(15), fddi-1(16), fddi-2(17), fddi-3(18), fddi-4(19), per-connector(20), isolated-1(21), isolated-2(22), isolated-3(23), isolated-4(24), isolated-5(25), isolated-6(26), isolated-7(27), isolated-8(28), isolated-9(29), isolated-10(30), isolated-11(31), ethernet-4(32), ethernet-5(33), ethernet-6(34), ethernet-7(35), ethernet-8(36)  

olModNetworkType 1.3.6.1.4.1.49.2.3.1.4.1.1.11
The network type of this module. port-switching(3) means that the network type differs depending on the port (like the router module). The network type reflects the valid values for olModNetwork.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(1), port-switching(3), ethernet(5), token-ring(6), fddi(7), serial(8)  

olModStatus 1.3.6.1.4.1.49.2.3.1.4.1.1.12
The module's status.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER okay(1), fatalError(10), booting(20), partial-failure(21)  

olModNumPorts 1.3.6.1.4.1.49.2.3.1.4.1.1.13
The number of ports on this module. Note, ports may be physical ports like 10BASE-T ports, or logical, like the bridge module ports.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

olModNumTrunks 1.3.6.1.4.1.49.2.3.1.4.1.1.14
The number of trunks on this module. Note, trunks are links that are, by definition, backbone connections. Examples of trunks are ring in and ring out ports for token ring, and the connections for rings to the backplane.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

olPortTable 1.3.6.1.4.1.49.2.3.1.4.2
A table that contains generic information about each port on each module present within the concentrator.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    OlPortEntry

olPortEntry 1.3.6.1.4.1.49.2.3.1.4.2.1
A list of information about each port in the concentrator.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  OlPortEntry  

olPortSlotIndex 1.3.6.1.4.1.49.2.3.1.4.2.1.1
The slot number of this port's module.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

olPortIndex 1.3.6.1.4.1.49.2.3.1.4.2.1.2
The port number of this port within this module.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

olPortType 1.3.6.1.4.1.49.2.3.1.4.2.1.3
The type of port. logical(1) is used to manage port resources that may not map directly to physical connections. The OEBM, for example, has two logical ports, although those two ports can be assigned to different combinations of four physical connections. media(2) refers to ports such as those on the 10BASE-T module.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER logical(1), media(2), virtual(5)  

olPortConnector 1.3.6.1.4.1.49.2.3.1.4.2.1.4
The connector type of this port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER backPlane(1), bnc(2), faui(3), maui(4), fiber(5), db-50(6), telco(7), rj45(8), rj45S(9), db-9(10), virtual(11), fddi-lc(12), fddi-st(13), fddi-mic(14), db-25(15), ethernet-sma(17), ethernet-fc(23), ethernet-st(24)  

olPortStatus 1.3.6.1.4.1.49.2.3.1.4.2.1.5
The status of this port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER okay(1), linkFailure(2), jabber(3), remoteLinkFailure(4), remoteJabber(5), invalidData(6), lowLight(7), fifoOverrun(8), fifoUnderrun(9), fatalError(10), partition(11), mjlp(12), noCable(13), noSquelch(14), noPhantom(15), okay-standby(19), off(22), connecting(23), backup-link(24), security-breach(25), unknownStatus(26), beacon(27), wireFault(28), macRemoved(29), notInserted(30), speedMismatch(31), attach3174Unknown(32), attach3174To8-3299(33), attach3174To32-3299(34), attach3174ToDirect(35), attach3174Unavailable(36), transientError(37)  

olPortAdminState 1.3.6.1.4.1.49.2.3.1.4.2.1.6
The desired state of this port. Setting a port to be redundant-primary(3) or redundant-backup requires that the buddy slot and buddy port also be set to valid values (see appropriate olSpecMods objects). If the values associated with the redundant buddys are not valid, a genError will be returned. If the port is already redundant, an invalid set may result in both ports being disabled.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2), redundant-primary(3), redundant-backup(4), redundant-rfs(5), local(6), remote(7), remote-diagnostics(8), unknown(9)  

olPortNetwork 1.3.6.1.4.1.49.2.3.1.4.2.1.7
The network that this port is attached to. If the value of olPortNetwork is per-module(4), then use the olModNetwork to manage this port. Setting olPortNetwork to a different value in this case will generate the invalidData error. Setting this port to a value that is not the same protocol type will return invalidData error. front-panel(5) is used for modules that have a logical port and a physical front connection. An example of this is the Eth2Eth Bridge module. Setting this port to a value that it does not support will generate an invalidData error.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER other(1), isolated(2), per-module(4), front-panel(5), ethernet-1(6), ethernet-2(7), ethernet-3(8), token-ring-1(9), token-ring-2(10), token-ring-3(11), token-ring-4(12), token-ring-5(13), token-ring-6(14), token-ring-7(15), fddi-1(16), fddi-2(17), fddi-3(18), fddi-4(19), per-connector(20), isolated-1(21), isolated-2(22), isolated-3(23), isolated-4(24), isolated-5(25), isolated-6(26), isolated-7(27), isolated-8(28), isolated-9(29), isolated-10(30), isolated-11(31), ethernet-4(32), ethernet-5(33), ethernet-6(34), ethernet-7(35), ethernet-8(36)  

olPortNetworkType 1.3.6.1.4.1.49.2.3.1.4.2.1.8
The network type of this port. The type reflects the valid values for olPortNetwork.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(1), ethernet(5), fddi(7), serial(8)  

olPortAlertFilter 1.3.6.1.4.1.49.2.3.1.4.2.1.9
Enabling this object for a port will allow the generation of port up (or port down) traps for port status transitions caused by end stations powering up (or down). Disabling this object will suppress the generation of port up (or port down) traps for a port. Note that this object is used in the trap generation decision only if chipAlertMode, an object in chipAlertTable, is set to filter(3). Some ports, such as integrated bridge or router ports do not support this feature. A getRequest on one of these types of ports will return a value of other(3), and a setRequest to enable(1) or disable(2) will return the invalidData object.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enable(1), disable(2), other(3)  

olTrunkTable 1.3.6.1.4.1.49.2.3.1.4.3
A table that contains generic information about each trunk on each module present within the concentrator.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    OlTrunkEntry

olTrunkEntry 1.3.6.1.4.1.49.2.3.1.4.3.1
A list of information about each trunk in the concentrator.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  OlTrunkEntry  

olTrunkSlotIndex 1.3.6.1.4.1.49.2.3.1.4.3.1.1
The slot number of this trunk's module.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

olTrunkIndex 1.3.6.1.4.1.49.2.3.1.4.3.1.2
The trunk number of this trunk.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

olTrunkType 1.3.6.1.4.1.49.2.3.1.4.3.1.3
The type of trunk. ringIn(3) and ringOut(4) refer to special trunks on the token ring protocol type modules.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(1), ringIn(3), ringOut(4), backplaneIn(6), backplaneOut(7)  

olTrunkConnector 1.3.6.1.4.1.49.2.3.1.4.3.1.4
The connector type of this trunk.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER backplane(1), fiber(5), rj45S(9)  

olTrunkStatus 1.3.6.1.4.1.49.2.3.1.4.3.1.5
The status of this trunk.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER okay(1), linkFailure(2), fatalError(10), noCable(13), noSquelch(14), lostLock(16), upstreamNeighborLost(17), invalidConfig(18), okay-standby(19), beacon(27), wireFault(28)  

olTrunkAdminState 1.3.6.1.4.1.49.2.3.1.4.3.1.6
The desired state of this trunk. Enabling a trunk allows the trunk to pass network traffic. This object may be used to configure fiber trunk redundancy. Setting a trunk to be redundant-primary(3) or redundant-backup(4) requires that the buddy slot be previously set to a valid value (see appropriate olSpecMods objects). If fiber trunk redundancy is already configured, setting this object to a redundant state will remove the previous configuration.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2), redundant-primary(3), redundant-backup(4)  

olTrunkWrapState 1.3.6.1.4.1.49.2.3.1.4.3.1.7
The wrap state of this trunk. A trunk can wrap in response to a network event such as a break in the cable.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER wrapped(1), unwrapped(2)  

olTrunkNeighbor 1.3.6.1.4.1.49.2.3.1.4.3.1.8
The upstream or downstream neighbor of the trunk.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER slot-1(1), slot-2(2), slot-3(3), slot-4(4), slot-5(5), slot-6(6), slot-7(7), slot-8(8), slot-9(9), slot-10(10), slot-11(11), slot-12(12), slot-13(13), slot-14(14), slot-15(15), slot-16(16), slot-17(17), external(256)  

ol50nnMCTLModTable 1.3.6.1.4.1.49.2.3.1.4.4.3.1
A table that contains information about each 50nnM-CTL in the concentrator. Note, current architecture will limit the number of instances to one per concentrator.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Ol50nnMCTLModEntry

ol50nnMCTLModEntry 1.3.6.1.4.1.49.2.3.1.4.4.3.1.1
A list of information for each 50nnM-CTL module in the concentrator.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Ol50nnMCTLModEntry  

ol50nnMCTLModSlotIndex 1.3.6.1.4.1.49.2.3.1.4.4.3.1.1.1
The slot number for this module.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ol50nnMCTLModTempStatus 1.3.6.1.4.1.49.2.3.1.4.4.3.1.1.2
The temperature as detected by the probes on this module.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER okay(1), extremeTemp(2)  

ol51nnMMGTModTable 1.3.6.1.4.1.49.2.3.1.4.4.4.1
A table that contains module information about each EMM module in the concentrator.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Ol51nnMMGTModEntry

ol51nnMMGTModEntry 1.3.6.1.4.1.49.2.3.1.4.4.4.1.1
A list of module information for a particular EMM module in the concentrator.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Ol51nnMMGTModEntry  

ol51nnMMGTModSlotIndex 1.3.6.1.4.1.49.2.3.1.4.4.4.1.1.1
The slot number of this module.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ol51nnMMGTModMasterPriority 1.3.6.1.4.1.49.2.3.1.4.4.4.1.1.2
The mastership priority of this agent. Ten is the highest and one is the lowest. Priority is only used when an election occurs. Mastership is not preemptive unless the reset mastership command is used.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER one(1), two(2), three(3), four(4), five(5), six(6), seven(7), eight(8), nine(9), ten(10)  

ol51nnMMGTModMasterStatus 1.3.6.1.4.1.49.2.3.1.4.4.4.1.1.3
The mastership status of this agent.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER master(1), non-master(2), electing(3)  

ol51nnMMGTModStationAddr 1.3.6.1.4.1.49.2.3.1.4.4.4.1.1.4
A 6 octet address that uniquely identifies this module. The station address is the mac address of port 1. Note that EMMs before v3.0 will have 00-00-00-00-00-00 as their station address.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(6)  

ol51nnMMGTPortTable 1.3.6.1.4.1.49.2.3.1.4.4.4.2
A table of information that contains port-specific information for each port on each 51nnM-MGT module.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Ol51nnMMGTPortEntry

ol51nnMMGTPortEntry 1.3.6.1.4.1.49.2.3.1.4.4.4.2.1
A list of information about a specific port on a 51nnM-MGT module.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Ol51nnMMGTPortEntry  

ol51nnMMGTPortSlotIndex 1.3.6.1.4.1.49.2.3.1.4.4.4.2.1.1
The slot number of this port's module.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ol51nnMMGTPortIndex 1.3.6.1.4.1.49.2.3.1.4.4.4.2.1.2
The port number of this port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ol51nnMMGTIpAddress 1.3.6.1.4.1.49.2.3.1.4.4.4.2.1.3
The IP Address associated with this port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  IpAddress  

ol51nnMFIBModTable 1.3.6.1.4.1.49.2.3.1.4.4.5.1
A table of module-specific information for each 51nnM-FIB module in the concentrator.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Ol51nnMFIBModEntry

ol51nnMFIBModEntry 1.3.6.1.4.1.49.2.3.1.4.4.5.1.1
A list of module-specific information associated with a particular 51nnM-FIB module in the concentrator.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Ol51nnMFIBModEntry  

ol51nnMFIBModSlotIndex 1.3.6.1.4.1.49.2.3.1.4.4.5.1.1.1
The slot number of this module.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ol51nnMFIBModDipNetwork 1.3.6.1.4.1.49.2.3.1.4.4.5.1.1.2
The network indicated by the module's dip switches.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER isolated(2), ethernet-1(6), ethernet-2(7), ethernet-3(8)  

ol51nnMFIBModLLW 1.3.6.1.4.1.49.2.3.1.4.4.5.1.1.3
The current state of this module's low light warning configuration. Enabling this feature causes the module to check for low light and to issue a warning if low light is present. Disabling low light has the advantage of faster redundancy switchover in the event of a port error.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

ol51nnMFIBModDipLLW 1.3.6.1.4.1.49.2.3.1.4.4.5.1.1.4
The low light warning configuration indicated by this module's dip switches.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

ol51nnMFIBPortTable 1.3.6.1.4.1.49.2.3.1.4.4.5.2
A table of port-specific information for each port of each 51nnM-FIB module.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Ol51nnMFIBPortEntry

ol51nnMFIBPortEntry 1.3.6.1.4.1.49.2.3.1.4.4.5.2.1
A list of information about a specific port on a 51nnM-FIB module.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Ol51nnMFIBPortEntry  

ol51nnMFIBPortSlotIndex 1.3.6.1.4.1.49.2.3.1.4.4.5.2.1.1
The slot number of this port's module.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ol51nnMFIBPortIndex 1.3.6.1.4.1.49.2.3.1.4.4.5.2.1.2
The port number of this port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ol51nnMFIBPortAdminState 1.3.6.1.4.1.49.2.3.1.4.4.5.2.1.3
The desired state of this port. Setting this port to be redundant with invalid settings of buddy slot and buddy port will return the genError error.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2), redundant-primary(3), redundant-backup(4)  

ol51nnMFIBPortBuddySlot 1.3.6.1.4.1.49.2.3.1.4.4.5.2.1.4
The slot index of the redundant port's buddy. To set a port to be redundant, the buddy's slot and port must be set to valid values. The buddy is automatically set to be redundant to this port.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

ol51nnMFIBPortBuddyPort 1.3.6.1.4.1.49.2.3.1.4.4.5.2.1.5
The port index of the redundant port's buddy. To set a port to be redundant, the buddy's slot and port must be set to valid values. The buddy is automatically set to be redundant to this port.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

ol51nnMFIBPortDipAdminState 1.3.6.1.4.1.49.2.3.1.4.4.5.2.1.6
The state of this port as indicated by the port's dip switches.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2), redundant-primary(3), redundant-backup(4)  

ol51nnMUTPModTable 1.3.6.1.4.1.49.2.3.1.4.4.6.1
A list of module-specific information associated with a particular 51nnM-UTP module in the concentrator.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Ol51nnMUTPModEntry

ol51nnMUTPModEntry 1.3.6.1.4.1.49.2.3.1.4.4.6.1.1
A module entry containing objects that describe the module level for that particular module.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Ol51nnMUTPModEntry  

ol51nnMUTPModSlotIndex 1.3.6.1.4.1.49.2.3.1.4.4.6.1.1.1
The slot number of this module.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ol51nnMUTPModDipNetwork 1.3.6.1.4.1.49.2.3.1.4.4.6.1.1.2
The network indicated by the module's dip switches.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER isolated(2), ethernet-1(6), ethernet-2(7), ethernet-3(8)  

ol51nnMUTPModCrossover 1.3.6.1.4.1.49.2.3.1.4.4.6.1.1.3
The current state of this module's crossover configuration. Setting this object to uncrossed(2) allows the last port to be used to connect to another repeater. Often this feature is used to connect one 10BASE-T module to another.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER crossed(1), uncrossed(2)  

ol51nnMUTPModDipCrossover 1.3.6.1.4.1.49.2.3.1.4.4.6.1.1.4
The crossover configuration indicated by this module's dip switches.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER crossed(1), uncrossed(2)  

ol51nnMUTPModFFL 1.3.6.1.4.1.49.2.3.1.4.4.6.1.1.5
The number of bits to store in the repeater's fifo buffer. See the module user's guide for more information.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER eight-bits(1), seven-bits(2)  

ol51nnMUTPModDipFFL 1.3.6.1.4.1.49.2.3.1.4.4.6.1.1.6
The fifo fill level as indicated by this module's dip switches.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER eight-bits(1), seven-bits(2)  

ol51nnMUTPPortTable 1.3.6.1.4.1.49.2.3.1.4.4.6.2
A table of port-specific information for each port of this module type.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Ol51nnMUTPPortEntry

ol51nnMUTPPortEntry 1.3.6.1.4.1.49.2.3.1.4.4.6.2.1
A port entry containing objects that describe this port.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Ol51nnMUTPPortEntry  

ol51nnMUTPPortSlotIndex 1.3.6.1.4.1.49.2.3.1.4.4.6.2.1.1
The slot number of this port's module.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ol51nnMUTPPortIndex 1.3.6.1.4.1.49.2.3.1.4.4.6.2.1.2
The port number of this port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ol51nnMUTPPortAdminState 1.3.6.1.4.1.49.2.3.1.4.4.6.2.1.3
The desired state of this port. Setting this port to be redundant with invalid settings of buddy slot and buddy port will return the genError error.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2), redundant-primary(3), redundant-backup(4)  

ol51nnMUTPPortBuddySlot 1.3.6.1.4.1.49.2.3.1.4.4.6.2.1.4
The slot index of the redundant port's buddy. To set a port to be redundant, the buddy's slot and port must be set to valid values. The buddy is automatically set to be redundant to this port.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

ol51nnMUTPPortBuddyPort 1.3.6.1.4.1.49.2.3.1.4.4.6.2.1.5
The port index of the redundant port's buddy. To set a port to be redundant, the buddy's slot and port must be set to valid values. The buddy is automatically set to be redundant to this port.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

ol51nnMUTPPortDipAdminState 1.3.6.1.4.1.49.2.3.1.4.4.6.2.1.6
The state of this port as indicated by the port's dip switches.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

ol51nnMUTPPortLinkInteg 1.3.6.1.4.1.49.2.3.1.4.4.6.2.1.7
The port's link integrity configuration. Enabling link integrity configures the port to conform to the link integrity feature as specified by 10BASE-T.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

ol51nnMUTPPortDipLinkInteg 1.3.6.1.4.1.49.2.3.1.4.4.6.2.1.8
The link integrity configuration as indicated by this port's dip switches.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

ol51nnMUTPPortSquelch 1.3.6.1.4.1.49.2.3.1.4.4.6.2.1.9
The port's squelch configuration. See the module's user's guide for more information.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER normal(1), low(2)  

ol51nnMUTPPortDipSquelch 1.3.6.1.4.1.49.2.3.1.4.4.6.2.1.10
The port's squelch configuration as indicated by this port's dip switches.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER normal(1), low(2)  

ol51nnMTPModTable 1.3.6.1.4.1.49.2.3.1.4.4.7.1
A table of module-specific information for each 51nnM-TP module in the concentrator.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Ol51nnMTPModEntry

ol51nnMTPModEntry 1.3.6.1.4.1.49.2.3.1.4.4.7.1.1
A list of module-specific information about a specific 51nnM-TP module in the concentrator.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Ol51nnMTPModEntry  

ol51nnMTPModSlotIndex 1.3.6.1.4.1.49.2.3.1.4.4.7.1.1.1
The slot number of this module.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ol51nnMTPModDipNetwork 1.3.6.1.4.1.49.2.3.1.4.4.7.1.1.2
The network indicated by the module's dip switches.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER isolated(2), ethernet-1(6), ethernet-2(7), ethernet-3(8)  

ol51nnMTPModCrossover 1.3.6.1.4.1.49.2.3.1.4.4.7.1.1.3
The current state of this module's crossover configuration. Setting this object to uncrossed(2) allows the last port to be used to connect to another repeater. Often this feature is used to connect one 10BASE-T module to another.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER crossed(1), uncrossed(2)  

ol51nnMTPModDipCrossover 1.3.6.1.4.1.49.2.3.1.4.4.7.1.1.4
The crossover configuration indicated by this module's dip switches.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER crossed(1), uncrossed(2)  

ol51nnMTPPortTable 1.3.6.1.4.1.49.2.3.1.4.4.7.2
A table of port-specific information for each port of this module type.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Ol51nnMTPPortEntry

ol51nnMTPPortEntry 1.3.6.1.4.1.49.2.3.1.4.4.7.2.1
A port entry containing objects that describe this port.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Ol51nnMTPPortEntry  

ol51nnMTPPortSlotIndex 1.3.6.1.4.1.49.2.3.1.4.4.7.2.1.1
The slot number of this port's module.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ol51nnMTPPortIndex 1.3.6.1.4.1.49.2.3.1.4.4.7.2.1.2
The port number of this port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ol51nnMTPPortAdminState 1.3.6.1.4.1.49.2.3.1.4.4.7.2.1.3
The desired state of this port. Setting this port to be redundant with invalid settings of buddy slot and buddy port will return the genError error.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2), redundant-primary(3), redundant-backup(4)  

ol51nnMTPPortBuddySlot 1.3.6.1.4.1.49.2.3.1.4.4.7.2.1.4
The slot index of the redundant port's buddy. To set a port to be redundant, the buddy's slot and port must be set to valid values. The buddy is automatically set to be redundant to this port.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

ol51nnMTPPortBuddyPort 1.3.6.1.4.1.49.2.3.1.4.4.7.2.1.5
The port index of the redundant port's buddy. To set a port to be redundant, the buddy's slot and port must be set to valid values. The buddy is automatically set to be redundant to this port.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

ol51nnMTPPortDipAdminState 1.3.6.1.4.1.49.2.3.1.4.4.7.2.1.6
The state of this port as indicated by the port's dip switches.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

ol51nnMTPPortLinkInteg 1.3.6.1.4.1.49.2.3.1.4.4.7.2.1.7
The port's link integrity configuration. Enabling link integrity configures the port to conform to the link integrity feature as specified by 10BASE-T.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

ol51nnMTPPortDipLinkInteg 1.3.6.1.4.1.49.2.3.1.4.4.7.2.1.8
The link integrity configuration as indicated by this port's dip switches.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

ol51nnMTPPortSquelch 1.3.6.1.4.1.49.2.3.1.4.4.7.2.1.9
The port's squelch configuration. See the module's user's guide for more information.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER normal(1), low(2)  

ol51nnMTPPortDipSquelch 1.3.6.1.4.1.49.2.3.1.4.4.7.2.1.10
The port's squelch configuration as indicated by this port's dip switches.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER normal(1), low(2)  

ol51nnMBNCModTable 1.3.6.1.4.1.49.2.3.1.4.4.8.1
A list of module-specific information associated with a particular 51nnM-BNC module in the concentrator.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Ol51nnMBNCModEntry

ol51nnMBNCModEntry 1.3.6.1.4.1.49.2.3.1.4.4.8.1.1
A module entry containing objects that describe the module level for that particular module.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Ol51nnMBNCModEntry  

ol51nnMBNCModSlotIndex 1.3.6.1.4.1.49.2.3.1.4.4.8.1.1.1
The slot number of this module.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ol51nnMBNCModDipNetwork 1.3.6.1.4.1.49.2.3.1.4.4.8.1.1.2
The network indicated by the module's dip switches.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER isolated(2), ethernet-1(6), ethernet-2(7), ethernet-3(8)  

ol51nnMBNCPortTable 1.3.6.1.4.1.49.2.3.1.4.4.8.2
A table of port-specific information for each port of this module type.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Ol51nnMBNCPortEntry

ol51nnMBNCPortEntry 1.3.6.1.4.1.49.2.3.1.4.4.8.2.1
A port entry containing objects that describe this port.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Ol51nnMBNCPortEntry  

ol51nnMBNCPortSlotIndex 1.3.6.1.4.1.49.2.3.1.4.4.8.2.1.1
The slot number of this port's module.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ol51nnMBNCPortIndex 1.3.6.1.4.1.49.2.3.1.4.4.8.2.1.2
The port number of this port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ol51nnMBNCPortDipAdminState 1.3.6.1.4.1.49.2.3.1.4.4.8.2.1.3
The state of this port as indicated by the port's dip switches.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

ol51nnMBNCPortDipTermination 1.3.6.1.4.1.49.2.3.1.4.4.8.2.1.4
The state of this port's termination as indicated by the port's dip switches.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER terminated(1), not-terminated(2)  

ol51nnMBNCPortDipGround 1.3.6.1.4.1.49.2.3.1.4.4.8.2.1.5
The state of this port's ground as indicated by the port's dip switches.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER grounded(1), not-grounded(2)  

ol51nnBEEModTable 1.3.6.1.4.1.49.2.3.1.4.4.9.1
A table of module-specific information for each 51nnB-EE module in the concentrator.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Ol51nnBEEModEntry

ol51nnBEEModEntry 1.3.6.1.4.1.49.2.3.1.4.4.9.1.1
A list of module-specific information about a specific 51nnB-EE module in the concentrator.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Ol51nnBEEModEntry  

ol51nnBEEModSlotIndex 1.3.6.1.4.1.49.2.3.1.4.4.9.1.1.1
The slot number of this module.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ol51nnBEEModStationAddr 1.3.6.1.4.1.49.2.3.1.4.4.9.1.1.2
A 6 octet address that uniquely identifies this module. The station address is the mac address of port 1.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(6)  

ol51nnBEEModProtocols 1.3.6.1.4.1.49.2.3.1.4.4.9.1.1.3
A textual description of the protocols supported by this module
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

ol51nnBEEPortTable 1.3.6.1.4.1.49.2.3.1.4.4.9.2
A table of port-specific for each port of each 51nnB-EE module in the concentrator.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Ol51nnBEEPortEntry

ol51nnBEEPortEntry 1.3.6.1.4.1.49.2.3.1.4.4.9.2.1
A list of port-specific informatoin about a specific 51nnB-EE port in the concentrator.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Ol51nnBEEPortEntry  

ol51nnBEEPortSlotIndex 1.3.6.1.4.1.49.2.3.1.4.4.9.2.1.1
The slot number for this port's module.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ol51nnBEEPortIndex 1.3.6.1.4.1.49.2.3.1.4.4.9.2.1.2
The port number for this port within this slot.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ol51nnBEEPortIpAddress 1.3.6.1.4.1.49.2.3.1.4.4.9.2.1.3
The IP Address associated with this port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  IpAddress  

ol51nnBEEPortDipNetwork 1.3.6.1.4.1.49.2.3.1.4.4.9.2.1.4
The network for this port as specified by this port's dip switches.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER isolated(2), front-panel(5), ethernet-1(6), ethernet-2(7), ethernet-3(8)  

ol51nnBEEPortDefNetwork 1.3.6.1.4.1.49.2.3.1.4.4.9.2.1.5
The network for this port as specified by the OEBM's non-volatile storage.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER isolated(2), front-panel(5), ethernet-1(6), ethernet-2(7), ethernet-3(8)  

ol51nnRESModTable 1.3.6.1.4.1.49.2.3.1.4.4.10.1
A table of module-specific information for each 51nnR-ES module in the concentrator.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Ol51nnRESModEntry

ol51nnRESModEntry 1.3.6.1.4.1.49.2.3.1.4.4.10.1.1
A list of module-specific information about a specific 51nnR-ES module in the concentrator.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Ol51nnRESModEntry  

ol51nnRESModSlotIndex 1.3.6.1.4.1.49.2.3.1.4.4.10.1.1.1
The slot number of this module.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ol51nnRESModStationAddr 1.3.6.1.4.1.49.2.3.1.4.4.10.1.1.2
A 6 octet address that uniquely identifies this module. The station address is the mac address of port 1.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(6)  

ol51nnRESModProtocols 1.3.6.1.4.1.49.2.3.1.4.4.10.1.1.3
A textual description of the protocols supported by this module
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

ol51nnRESPortTable 1.3.6.1.4.1.49.2.3.1.4.4.10.2
A table of port-specific for each port of each 51nnR-ES module in the concentrator.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Ol51nnRESPortEntry

ol51nnRESPortEntry 1.3.6.1.4.1.49.2.3.1.4.4.10.2.1
A list of port-specific informatoin about a specific 51nnR-ES port in the concentrator.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Ol51nnRESPortEntry  

ol51nnRESPortSlotIndex 1.3.6.1.4.1.49.2.3.1.4.4.10.2.1.1
The slot number for this port's module.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ol51nnRESPortIndex 1.3.6.1.4.1.49.2.3.1.4.4.10.2.1.2
The port number for this port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ol51nnRESPortIpAddress 1.3.6.1.4.1.49.2.3.1.4.4.10.2.1.3
The IP Address associated with this port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  IpAddress  

ol51nnRESPortDipNetwork 1.3.6.1.4.1.49.2.3.1.4.4.10.2.1.4
The network for this port as specified by this port's dip switches.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER isolated(2), front-panel(5), ethernet-1(6), ethernet-2(7), ethernet-3(8)  

ol51nnRESPortDefNetwork 1.3.6.1.4.1.49.2.3.1.4.4.10.2.1.5
The network for this port as specified by the OERM's non-volatile storage.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER isolated(2), front-panel(5), ethernet-1(6), ethernet-2(7), ethernet-3(8)  

ol51nnREEModTable 1.3.6.1.4.1.49.2.3.1.4.4.11.1
A table of module-specific information for each 51nnR-EE module in the concentrator.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Ol51nnREEModEntry

ol51nnREEModEntry 1.3.6.1.4.1.49.2.3.1.4.4.11.1.1
A list of module-specific information about a specific 51nnR-EE module in the concentrator.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Ol51nnREEModEntry  

ol51nnREEModSlotIndex 1.3.6.1.4.1.49.2.3.1.4.4.11.1.1.1
The slot number of this module.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ol51nnREEModStationAddr 1.3.6.1.4.1.49.2.3.1.4.4.11.1.1.2
A 6 octet address that uniquely identifies this module. The station address is the mac address of port 1.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(6)  

ol51nnREEModProtocols 1.3.6.1.4.1.49.2.3.1.4.4.11.1.1.3
A textual description of the protocols supported by this module
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

ol51nnREEPortTable 1.3.6.1.4.1.49.2.3.1.4.4.11.2
A table of port-specific for each port of each 51nnR-EE module in the concentrator.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Ol51nnREEPortEntry

ol51nnREEPortEntry 1.3.6.1.4.1.49.2.3.1.4.4.11.2.1
A list of port-specific informatoin about a specific 51nnR-EE port in the concentrator.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Ol51nnREEPortEntry  

ol51nnREEPortSlotIndex 1.3.6.1.4.1.49.2.3.1.4.4.11.2.1.1
The slot number for this port's module.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ol51nnREEPortIndex 1.3.6.1.4.1.49.2.3.1.4.4.11.2.1.2
The port number of this port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ol51nnREEPortIpAddress 1.3.6.1.4.1.49.2.3.1.4.4.11.2.1.3
The IP Address associated with this port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  IpAddress  

ol51nnREEPortDipNetwork 1.3.6.1.4.1.49.2.3.1.4.4.11.2.1.4
The network for this port as specified by this port's dip switches.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER isolated(2), front-panel(5), ethernet-1(6), ethernet-2(7), ethernet-3(8)  

ol51nnREEPortDefNetwork 1.3.6.1.4.1.49.2.3.1.4.4.11.2.1.5
The network for this port as specified by the OERM's non-volatile storage.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER isolated(2), front-panel(5), ethernet-1(6), ethernet-2(7), ethernet-3(8)  

ol51nnMAUIFModTable 1.3.6.1.4.1.49.2.3.1.4.4.12.1
A list of module-specific information associated with a particular 51nnM-AUIF module in the concentrator.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Ol51nnMAUIFModEntry

ol51nnMAUIFModEntry 1.3.6.1.4.1.49.2.3.1.4.4.12.1.1
A list of module-specific information about a specific 51nnM-AUIF module in the concentrator.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Ol51nnMAUIFModEntry  

ol51nnMAUIFModSlotIndex 1.3.6.1.4.1.49.2.3.1.4.4.12.1.1.1
The slot number of this module.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ol51nnMAUIFPortTable 1.3.6.1.4.1.49.2.3.1.4.4.12.2
A table of port-specific information for each port of this module type.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Ol51nnMAUIFPortEntry

ol51nnMAUIFPortEntry 1.3.6.1.4.1.49.2.3.1.4.4.12.2.1
A list of module-specific information about a specific 51nnM-AUIF port in the concentrator.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Ol51nnMAUIFPortEntry  

ol51nnMAUIFPortSlotIndex 1.3.6.1.4.1.49.2.3.1.4.4.12.2.1.1
The slot number of this port's module.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ol51nnMAUIFPortIndex 1.3.6.1.4.1.49.2.3.1.4.4.12.2.1.2
The port number of this port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ol51nnMAUIFPortAdminState 1.3.6.1.4.1.49.2.3.1.4.4.12.2.1.3
The desired state of this port. Setting this port to be redundant with invalid settings of buddy slot and buddy port will return the genError error.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2), redundant-primary(3), redundant-backup(4)  

ol51nnMAUIFPortBuddySlot 1.3.6.1.4.1.49.2.3.1.4.4.12.2.1.4
The slot index of the redundant port's buddy. To set a port to be redundant, the buddy's slot and port must be set to valid values. The buddy is automatically set to be redundant to this port.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

ol51nnMAUIFPortBuddyPort 1.3.6.1.4.1.49.2.3.1.4.4.12.2.1.5
The port index of the redundant port's buddy. To set a port to be redundant, the buddy's slot and port must be set to valid values. The buddy is automatically set to be redundant to this port.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

ol51nnMAUIFPortDipAdminState 1.3.6.1.4.1.49.2.3.1.4.4.12.2.1.6
The state of this port as indicated by the port's dip switches.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2), redundant-primary(3), redundant-backup(4)  

ol51nnMAUIFPortDipNetwork 1.3.6.1.4.1.49.2.3.1.4.4.12.2.1.7
The network indicated by the port's dip switches.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER isolated(2), ethernet-1(6), ethernet-2(7), ethernet-3(8)  

ol51nnMAUIMModTable 1.3.6.1.4.1.49.2.3.1.4.4.13.1
A list of module-specific information associated with a particular 51nnM-AUIM module in the concentrator.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Ol51nnMAUIMModEntry

ol51nnMAUIMModEntry 1.3.6.1.4.1.49.2.3.1.4.4.13.1.1
A list of module-specific information about a specific 51nnM-AUIM module in the concentrator.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Ol51nnMAUIMModEntry  

ol51nnMAUIMModSlotIndex 1.3.6.1.4.1.49.2.3.1.4.4.13.1.1.1
The slot number of this module.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ol51nnMAUIMPortTable 1.3.6.1.4.1.49.2.3.1.4.4.13.2
A table of port-specific information for each port of this module type.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Ol51nnMAUIMPortEntry

ol51nnMAUIMPortEntry 1.3.6.1.4.1.49.2.3.1.4.4.13.2.1
A list of module-specific information about a specific 51nnM-AUIM port in the concentrator.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Ol51nnMAUIMPortEntry  

ol51nnMAUIMPortSlotIndex 1.3.6.1.4.1.49.2.3.1.4.4.13.2.1.1
The slot number of this port's module.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ol51nnMAUIMPortIndex 1.3.6.1.4.1.49.2.3.1.4.4.13.2.1.2
The port number of this port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ol51nnMAUIMPortAdminState 1.3.6.1.4.1.49.2.3.1.4.4.13.2.1.3
The desired state of this port. Setting this port to be redundant with invalid settings of buddy slot and buddy port will return the genError error.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2), redundant-primary(3), redundant-backup(4)  

ol51nnMAUIMPortBuddySlot 1.3.6.1.4.1.49.2.3.1.4.4.13.2.1.4
The slot index of the redundant port's buddy. To set a port to be redundant, the buddy's slot and port must be set to valid values. The buddy is automatically set to be redundant to this port.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

ol51nnMAUIMPortBuddyPort 1.3.6.1.4.1.49.2.3.1.4.4.13.2.1.5
The port index of the redundant port's buddy. To set a port to be redundant, the buddy's slot and port must be set to valid values. The buddy is automatically set to be redundant to this port.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

ol51nnMAUIMPortDipAdminState 1.3.6.1.4.1.49.2.3.1.4.4.13.2.1.6
The state of this port as indicated by the port's dip switches.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

ol51nnMAUIMPortDipNetwork 1.3.6.1.4.1.49.2.3.1.4.4.13.2.1.7
The network indicated by the port's dip switches.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER isolated(2), ethernet-1(6), ethernet-2(7), ethernet-3(8)  

ol51nnMAUIMPortSQETest 1.3.6.1.4.1.49.2.3.1.4.4.13.2.1.8
The current SQE test configuration for this port.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

ol51nnMAUIMPortDipSQETest 1.3.6.1.4.1.49.2.3.1.4.4.13.2.1.9
The SQE test configuration for this port as indicated by the port's dip switches.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

ol51nnMAUIMPortCollision 1.3.6.1.4.1.49.2.3.1.4.4.13.2.1.10
The current collision configuration for this port.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER normal(1), alternate(2)  

ol51nnMAUIMPortDipCollision 1.3.6.1.4.1.49.2.3.1.4.4.13.2.1.11
The collision configuration for this port as indicated by the port's dip switches.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER normal(1), alternate(2)  

ol51nnMAUIMPortHalfStep 1.3.6.1.4.1.49.2.3.1.4.4.13.2.1.12
The current step configuration for this port.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

ol51nnMAUIMPortDipHalfStep 1.3.6.1.4.1.49.2.3.1.4.4.13.2.1.13
The step configuration for this port as indicated by the port's dip switches.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

ol5208MTPModTable 1.3.6.1.4.1.49.2.3.1.4.4.14.1
A list of module-specific information associated with a particular 5208M-TP module in the concentrator.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Ol5208MTPModEntry

ol5208MTPModEntry 1.3.6.1.4.1.49.2.3.1.4.4.14.1.1
A description of the 5208M-TP module attributes.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Ol5208MTPModEntry  

ol5208MTPModSlotIndex 1.3.6.1.4.1.49.2.3.1.4.4.14.1.1.1
The slot number of this module.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ol5208MTPModBypsAdminState 1.3.6.1.4.1.49.2.3.1.4.4.14.1.1.2
The desired state of this module with respect to the ring. Setting this attribute to bypass(2) will cause this module to be removed from the ring that passes through the module's ring in and ring out ports.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER insert(1), bypass(2)  

ol5208MTPModBypsOperState 1.3.6.1.4.1.49.2.3.1.4.4.14.1.1.3
The operational state of this module with respect to the ring. If this attribute is equal to bypass(2), then the module has been removed from the ring that passes through the module's ring in and ring out ports.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER insert(1), bypass(2)  

ol5208MTPModDipCableImp 1.3.6.1.4.1.49.2.3.1.4.4.14.1.1.4
The setting of this module's port impedance matching, with 100 ohm corresponding to unshielded twisted pair cabling and 150 ohm corresponding to shielded twisted pair cabling. This setting is valid for all ports on this module.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ohm100(1), ohm150(2)  

ol5208MTPPortTable 1.3.6.1.4.1.49.2.3.1.4.4.14.2
A table of port-specific information for each port of this module type.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Ol5208MTPPortEntry

ol5208MTPPortEntry 1.3.6.1.4.1.49.2.3.1.4.4.14.2.1
A description of 5208M-TP port attributes.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Ol5208MTPPortEntry  

ol5208MTPPortSlotIndex 1.3.6.1.4.1.49.2.3.1.4.4.14.2.1.1
The slot number of this port's module.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ol5208MTPPortIndex 1.3.6.1.4.1.49.2.3.1.4.4.14.2.1.2
The port number of this port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ol5208MTPPortDipAdminState 1.3.6.1.4.1.49.2.3.1.4.4.14.2.1.3
The state of this port as indicated by the port's dip switches.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

ol5208MTPPortStationType 1.3.6.1.4.1.49.2.3.1.4.4.14.2.1.4
Determines whether the station connected to this port has a MAC address.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER mac-present(1), mac-not-present(2)  

ol5208MTPTrunkTable 1.3.6.1.4.1.49.2.3.1.4.4.14.3
A list of trunk-specific information about each trunk for this module type.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Ol5208MTPTrunkEntry

ol5208MTPTrunkEntry 1.3.6.1.4.1.49.2.3.1.4.4.14.3.1
A description of 5208M-TP trunk attributes.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Ol5208MTPTrunkEntry  

ol5208MTPTrunkSlotIndex 1.3.6.1.4.1.49.2.3.1.4.4.14.3.1.1
A unique value that identifies a particular module. Its value ranges between 1 and olModSlotNumber. The module identified by a particular value of this index is the same module as indentified by the same value of olTrunkSlotIndex.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ol5208MTPTrunkIndex 1.3.6.1.4.1.49.2.3.1.4.4.14.3.1.2
The trunk number for this trunk.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ol5208MTPTrunkDipAdminState 1.3.6.1.4.1.49.2.3.1.4.4.14.3.1.3
The state of this trunk as indicated by the trunk's dip switches.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

ol5208MTPTrunkCableMon 1.3.6.1.4.1.49.2.3.1.4.4.14.3.1.4
The cable monitor configuration for this trunk.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2), notApplicable(3)  

ol5208MTPTrunkDipCableMon 1.3.6.1.4.1.49.2.3.1.4.4.14.3.1.5
The cable monitor configuration as indicated by this trunk's dip switches.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2), notApplicable(3)  

ol5208MTPTrunkNetMapState 1.3.6.1.4.1.49.2.3.1.4.4.14.3.1.6
The map state of the copper ring-in trunk. This should be set to external for ring-in trunks which connect to external hubs. The mapping logic will not operate on trunks which are set to external. This prevents incorrect mapping which can occur when a module in one hub detects the mapping signal from another hub. This attribute only applies to copper ring-in trunks.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), internal(2), external(3)  

ol5208MTPTrunkExtBcnRecovery 1.3.6.1.4.1.49.2.3.1.4.4.14.3.1.7
Indicates whether the trunk is connected to a segment that will perform beacon recovery. This should be set to exists(1) for trunks which connect to hubs which perform beacon recovery. This attribute is used to determine the fault domain when resolving a beaconing condition. The beacon recovery process will resolve beaconing on trunks with this attribute set to nonExists(2) before trunks with the attribute set to exists(1) are resolved. For backplane trunks, setting to a value other than notApplicable will return invalidData error. The default value is nonExists(2).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER exists(1), nonExists(2), notApplicable(3)  

ol51nnMFPModTable 1.3.6.1.4.1.49.2.3.1.4.4.15.1
A list of module-specific information associated with a particular 51nnM-FP module in the concentrator.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Ol51nnMFPModEntry

ol51nnMFPModEntry 1.3.6.1.4.1.49.2.3.1.4.4.15.1.1
A list of module-specific information about a specific 51nnM-FP module in the concentrator.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Ol51nnMFPModEntry  

ol51nnMFPModSlotIndex 1.3.6.1.4.1.49.2.3.1.4.4.15.1.1.1
The slot number of this module.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ol51nnMFPPortTable 1.3.6.1.4.1.49.2.3.1.4.4.15.2
A table of port-specific information for each port of this module type.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Ol51nnMFPPortEntry

ol51nnMFPPortEntry 1.3.6.1.4.1.49.2.3.1.4.4.15.2.1
A list of module-specific information about a specific 51nnM-FP port in the concentrator.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Ol51nnMFPPortEntry  

ol51nnMFPPortSlotIndex 1.3.6.1.4.1.49.2.3.1.4.4.15.2.1.1
The slot number of this port's module.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ol51nnMFPPortIndex 1.3.6.1.4.1.49.2.3.1.4.4.15.2.1.2
The port number of this port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ol51nnMFPPortAdminState 1.3.6.1.4.1.49.2.3.1.4.4.15.2.1.3
The desired state of this port. Setting this port to be redundant with invalid settings of buddy slot and buddy port will return the genError error.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2), redundant-primary(3), redundant-backup(4)  

ol51nnMFPPortBuddySlot 1.3.6.1.4.1.49.2.3.1.4.4.15.2.1.4
The slot index of the redundant port's buddy. To set a port to be redundant, the buddy's slot and port must be set to valid values. The buddy is automatically set to be redundant to this port.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

ol51nnMFPPortBuddyPort 1.3.6.1.4.1.49.2.3.1.4.4.15.2.1.5
The port index of the redundant port's buddy. To set a port to be redundant, the buddy's slot and port must be set to valid values. The buddy is automatically set to be redundant to this port.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

ol51nnMFPPortDipAdminState 1.3.6.1.4.1.49.2.3.1.4.4.15.2.1.6
The state of this port as indicated by the port's dip switches.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2), redundant-primary(3), redundant-backup(4)  

ol51nnMFPPortDipNetwork 1.3.6.1.4.1.49.2.3.1.4.4.15.2.1.7
The network indicated by the port's dip switches.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER isolated(2), ethernet-1(6), ethernet-2(7), ethernet-3(8)  

ol51nnMFPPortLLW 1.3.6.1.4.1.49.2.3.1.4.4.15.2.1.8
The current low light warning configuration for this port.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

ol51nnMFPPortDipLLW 1.3.6.1.4.1.49.2.3.1.4.4.15.2.1.9
The low light warning configuration indicated by this module's dip switches.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

ol51nnMFPPortHipwr 1.3.6.1.4.1.49.2.3.1.4.4.15.2.1.10
The current high power optic configuration for this port.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

ol51nnMFPPortDipHipwr 1.3.6.1.4.1.49.2.3.1.4.4.15.2.1.11
The high power optic configuration for this port as indicated by the port's dip switches.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

ol51nnMFBPModTable 1.3.6.1.4.1.49.2.3.1.4.4.16.1
A list of module-specific information associated with a particular 51nnM-FBP module in the concentrator.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Ol51nnMFBPModEntry

ol51nnMFBPModEntry 1.3.6.1.4.1.49.2.3.1.4.4.16.1.1
A list of module-specific information about a specific 51nnM-FBP module in the concentrator.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Ol51nnMFBPModEntry  

ol51nnMFBPModSlotIndex 1.3.6.1.4.1.49.2.3.1.4.4.16.1.1.1
The slot number of this module.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ol51nnMFBPPortTable 1.3.6.1.4.1.49.2.3.1.4.4.16.2
A table of port-specific information for each port of this module type.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Ol51nnMFBPPortEntry

ol51nnMFBPPortEntry 1.3.6.1.4.1.49.2.3.1.4.4.16.2.1
A list of module-specific information about a specific 51nnM-FBP port in the concentrator.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Ol51nnMFBPPortEntry  

ol51nnMFBPPortSlotIndex 1.3.6.1.4.1.49.2.3.1.4.4.16.2.1.1
The slot number of this port's module.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ol51nnMFBPPortIndex 1.3.6.1.4.1.49.2.3.1.4.4.16.2.1.2
The port number of this port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ol51nnMFBPPortAdminState 1.3.6.1.4.1.49.2.3.1.4.4.16.2.1.3
The desired state of this port. Setting this port to be redundant with invalid settings of buddy slot and buddy port will return the genError error.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2), redundant-primary(3), redundant-backup(4)  

ol51nnMFBPPortBuddySlot 1.3.6.1.4.1.49.2.3.1.4.4.16.2.1.4
The slot index of the redundant port's buddy. To set a port to be redundant, the buddy's slot and port must be set to valid values. The buddy is automatically set to be redundant to this port.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

ol51nnMFBPPortBuddyPort 1.3.6.1.4.1.49.2.3.1.4.4.16.2.1.5
The port index of the redundant port's buddy. To set a port to be redundant, the buddy's slot and port must be set to valid values. The buddy is automatically set to be redundant to this port.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

ol51nnMFBPPortDipAdminState 1.3.6.1.4.1.49.2.3.1.4.4.16.2.1.6
The state of this port as indicated by the port's dip switches.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2), redundant-primary(3), redundant-backup(4)  

ol51nnMFBPPortDipNetwork 1.3.6.1.4.1.49.2.3.1.4.4.16.2.1.7
The network indicated by the port's dip switches.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER isolated(2), ethernet-1(6), ethernet-2(7), ethernet-3(8)  

ol51nnMFBPPortLLW 1.3.6.1.4.1.49.2.3.1.4.4.16.2.1.8
The current low light warning configuration for this port.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

ol51nnMFBPPortDipLLW 1.3.6.1.4.1.49.2.3.1.4.4.16.2.1.9
The low light warning configuration indicated by this module's dip switches.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

ol51nnMFBPPortHipwr 1.3.6.1.4.1.49.2.3.1.4.4.16.2.1.10
The current high power optic configuration for this port.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

ol51nnMFBPPortDipHipwr 1.3.6.1.4.1.49.2.3.1.4.4.16.2.1.11
The high power optic configuration for this port as indicated by the port's dip switches.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

ol51nnMTPLModTable 1.3.6.1.4.1.49.2.3.1.4.4.17.1
A list of module-specific information associated with a particular 51nnM-TPL module in the concentrator.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Ol51nnMTPLModEntry

ol51nnMTPLModEntry 1.3.6.1.4.1.49.2.3.1.4.4.17.1.1
A list of module-specific information about a specific 51nnM-TPL module in the concentrator.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Ol51nnMTPLModEntry  

ol51nnMTPLModSlotIndex 1.3.6.1.4.1.49.2.3.1.4.4.17.1.1.1
The slot number of this module.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ol51nnMTPLModDipNetwork 1.3.6.1.4.1.49.2.3.1.4.4.17.1.1.2
The network indicated by the module's dip switches.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER isolated(2), ethernet-1(6), ethernet-2(7), ethernet-3(8)  

ol51nnMTPLPortTable 1.3.6.1.4.1.49.2.3.1.4.4.17.2
A table of port-specific information for each port of this module type.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Ol51nnMTPLPortEntry

ol51nnMTPLPortEntry 1.3.6.1.4.1.49.2.3.1.4.4.17.2.1
A list of module-specific information about a specific 51nnM-TPL port in the concentrator.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Ol51nnMTPLPortEntry  

ol51nnMTPLPortSlotIndex 1.3.6.1.4.1.49.2.3.1.4.4.17.2.1.1
The slot number of this port's module.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ol51nnMTPLPortIndex 1.3.6.1.4.1.49.2.3.1.4.4.17.2.1.2
The port number of this port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ol51nnMTPLPortAdminState 1.3.6.1.4.1.49.2.3.1.4.4.17.2.1.3
The desired state of this port. Setting this port to be redundant or for remote diagnostics with invalid settings of buddy slot and buddy port will return the genError error.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2), redundant-primary(3), redundant-backup(4), remote-diagnostics(8)  

ol51nnMTPLPortBuddySlot 1.3.6.1.4.1.49.2.3.1.4.4.17.2.1.4
The slot index of the redundant port's buddy. To set a port to be redundant, the buddy's slot and port must be set to valid values. The buddy is automatically set to be redundant to this port. If the port is configured for remote diagnostics, then this contains the slot index of the backup buddy port. To configure a port for remote diagnostics, the buddy's slot and port must be set to valid values.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

ol51nnMTPLPortBuddyPort 1.3.6.1.4.1.49.2.3.1.4.4.17.2.1.5
The port index of the redundant port's buddy. To set a port to be redundant, the buddy's slot and port must be set to valid values. The buddy is automatically set to be redundant to this port. If the port is configured for remote diagnostics, then this contains the port index of the backup buddy port. To configure a port for remote diagnostics, the buddy's slot and port must be set to valid values.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

ol51nnMTPLPortDipAdminState 1.3.6.1.4.1.49.2.3.1.4.4.17.2.1.6
The state of this port as indicated by the port's dip switches.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

ol51nnMTPLPortLinkInteg 1.3.6.1.4.1.49.2.3.1.4.4.17.2.1.7
The current link integrity configuration for this port.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

ol51nnMTPLPortDipLinkInteg 1.3.6.1.4.1.49.2.3.1.4.4.17.2.1.8
The link integrity configuration as indicated by this module's dip switches.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

ol51nnMTPLPortSquelch 1.3.6.1.4.1.49.2.3.1.4.4.17.2.1.9
The current squelch configuration for this port. See the module's user's guide for more information.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER normal(1), low(2)  

ol51nnMTPLPortJabber 1.3.6.1.4.1.49.2.3.1.4.4.17.2.1.10
The current receive jabber configuration for this port.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

ol51nnMTPLPortDipJabber 1.3.6.1.4.1.49.2.3.1.4.4.17.2.1.11
The receive jabber configuration as indicated by this module's dip switches.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

ol51nnMTPPLModTable 1.3.6.1.4.1.49.2.3.1.4.4.18.1
A list of module-specific information about a specific 51nnM-TPPL module in the concentrator.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Ol51nnMTPPLModEntry

ol51nnMTPPLModEntry 1.3.6.1.4.1.49.2.3.1.4.4.18.1.1
A list of module-specific information about a specific 51nnM-TPPL module in the concentrator.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Ol51nnMTPPLModEntry  

ol51nnMTPPLModSlotIndex 1.3.6.1.4.1.49.2.3.1.4.4.18.1.1.1
The slot number of this module.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ol51nnMTPPLPortTable 1.3.6.1.4.1.49.2.3.1.4.4.18.2
A table of port-specific information for each port of this module type.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Ol51nnMTPPLPortEntry

ol51nnMTPPLPortEntry 1.3.6.1.4.1.49.2.3.1.4.4.18.2.1
A list of module-specific information about a specific 51nnM-TPPL port in the concentrator.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Ol51nnMTPPLPortEntry  

ol51nnMTPPLPortSlotIndex 1.3.6.1.4.1.49.2.3.1.4.4.18.2.1.1
The slot number of this port's module.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ol51nnMTPPLPortIndex 1.3.6.1.4.1.49.2.3.1.4.4.18.2.1.2
The port number of this port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ol51nnMTPPLPortAdminState 1.3.6.1.4.1.49.2.3.1.4.4.18.2.1.3
The desired state of this port. Setting this port to be redundant or for remote diagnostics with invalid settings of buddy slot and buddy port will return the genError error.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2), redundant-primary(3), redundant-backup(4), remote-diagnostics(8)  

ol51nnMTPPLPortBuddySlot 1.3.6.1.4.1.49.2.3.1.4.4.18.2.1.4
The slot index of the redundant port's buddy. To set a port to be redundant, the buddy's slot and port must be set to valid values. The buddy is automatically set to be redundant to this port. If the port is configured for remote diagnostics, then this contains the slot index of the backup buddy port. To configure a port for remote diagnostics, the buddy's slot and port must be set to valid values.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

ol51nnMTPPLPortBuddyPort 1.3.6.1.4.1.49.2.3.1.4.4.18.2.1.5
The port index of the redundant port's buddy. To set a port to be redundant, the buddy's slot and port must be set to valid values. The buddy is automatically set to be redundant to this port. If the port is configured for remote diagnostics, then this contains the port index of the backup buddy port. To configure a port for remote diagnostics, the buddy's slot and port must be set to valid values.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

ol51nnMTPPLPortDipAdminState 1.3.6.1.4.1.49.2.3.1.4.4.18.2.1.6
The state of this port as indicated by the port's dip switches.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

ol51nnMTPPLPortDipNetwork 1.3.6.1.4.1.49.2.3.1.4.4.18.2.1.7
The network indicated by the port's dip switches.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER isolated(2), ethernet-1(6), ethernet-2(7), ethernet-3(8)  

ol51nnMTPPLPortLinkInteg 1.3.6.1.4.1.49.2.3.1.4.4.18.2.1.8
The current link integrity configuration for this port.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

ol51nnMTPPLPortDipLinkInteg 1.3.6.1.4.1.49.2.3.1.4.4.18.2.1.9
The link integrity configuration as indicated by this module's dip switches.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

ol51nnMTPPLPortSquelch 1.3.6.1.4.1.49.2.3.1.4.4.18.2.1.10
The current squelch configuration for this port. See the module's user's guide for more information.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER normal(1), low(2)  

ol51nnMTPPLPortJabber 1.3.6.1.4.1.49.2.3.1.4.4.18.2.1.11
The current receive jabber configuration for this port.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

ol51nnMTPPLPortDipJabber 1.3.6.1.4.1.49.2.3.1.4.4.18.2.1.12
The receive jabber configuration as indicated by this module's dip switches.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

ol52nnMTPModTable 1.3.6.1.4.1.49.2.3.1.4.4.19.1
A list of module-specific information about a specific 52nnM-TP module in the concentrator.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Ol52nnMTPModEntry

ol52nnMTPModEntry 1.3.6.1.4.1.49.2.3.1.4.4.19.1.1
A description of the 52nnM-TP module attributes.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Ol52nnMTPModEntry  

ol52nnMTPModSlotIndex 1.3.6.1.4.1.49.2.3.1.4.4.19.1.1.1
A unique value that identifies a particular module. Its value ranges between 1 and olModSlotNumber. The module identified by a particular value of this index is the same module as indentified by the same value of olModSlotIndex.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ol52nnMTPModRingSpeed 1.3.6.1.4.1.49.2.3.1.4.4.19.1.1.2
The ring's bandwidth.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER fourMegabit(1), sixteenMegabit(2)  

ol52nnMTPModDipRingSpeed 1.3.6.1.4.1.49.2.3.1.4.4.19.1.1.3
The dip switch setting for the ring's bandwidth.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER fourMegabit(1), sixteenMegabit(2)  

ol52nnMTPModCableImp 1.3.6.1.4.1.49.2.3.1.4.4.19.1.1.4
The setting of this module's port impedance matching, with 100 ohm corresponding to unshielded twisted pair cabling and 150 ohm corresponding to shielded twisted pair cabling. This setting is valid for all ports on this module.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER ohm100(1), ohm150(2)  

ol52nnMTPModDipCableImp 1.3.6.1.4.1.49.2.3.1.4.4.19.1.1.5
The dip switch setting for the module's port impedance matching.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ohm100(1), ohm150(2)  

ol52nnMTPPortTable 1.3.6.1.4.1.49.2.3.1.4.4.19.2
A table of port-specific information for each port of this module type.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Ol52nnMTPPortEntry

ol52nnMTPPortEntry 1.3.6.1.4.1.49.2.3.1.4.4.19.2.1
A description of 52nnM-TP port attributes.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Ol52nnMTPPortEntry  

ol52nnMTPPortSlotIndex 1.3.6.1.4.1.49.2.3.1.4.4.19.2.1.1
The slot number of this port's module.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ol52nnMTPPortIndex 1.3.6.1.4.1.49.2.3.1.4.4.19.2.1.2
The port number of this port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ol52nnMTPPortDipAdminState 1.3.6.1.4.1.49.2.3.1.4.4.19.2.1.3
The state of this port as indicated by the port's dip switches.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

ol52nnMTPPortStationType 1.3.6.1.4.1.49.2.3.1.4.4.19.2.1.4
Determines whether the station connected to this port has a MAC address.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER mac-present(1), mac-not-present(2)  

ol52nnMTPTrunkTable 1.3.6.1.4.1.49.2.3.1.4.4.19.3
A list of trunk-specific information about each trunk for this module type.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Ol52nnMTPTrunkEntry

ol52nnMTPTrunkEntry 1.3.6.1.4.1.49.2.3.1.4.4.19.3.1
A description of 52nnM-TP trunk attributes.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Ol52nnMTPTrunkEntry  

ol52nnMTPTrunkSlotIndex 1.3.6.1.4.1.49.2.3.1.4.4.19.3.1.1
A unique value that identifies a particular module. Its value ranges between 1 and olModSlotNumber. The module identified by a particular value of this index is the same module as indentified by the same value of olTrunkSlotIndex.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ol52nnMTPTrunkIndex 1.3.6.1.4.1.49.2.3.1.4.4.19.3.1.2
The trunk number for this trunk.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ol52nnMTPTrunkDipAdminState 1.3.6.1.4.1.49.2.3.1.4.4.19.3.1.3
The state of this trunk as indicated by the trunk's dip switches.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

ol52nnMFRModTable 1.3.6.1.4.1.49.2.3.1.4.4.20.1
A list of module-specific information about a specific 52nnM-FR module in the concentrator.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Ol52nnMFRModEntry

ol52nnMFRModEntry 1.3.6.1.4.1.49.2.3.1.4.4.20.1.1
A description of the 52nnM-FR module attributes.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Ol52nnMFRModEntry  

ol52nnMFRModSlotIndex 1.3.6.1.4.1.49.2.3.1.4.4.20.1.1.1
The slot number of this module.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ol52nnMFRModRingSpeed 1.3.6.1.4.1.49.2.3.1.4.4.20.1.1.2
The ring's bandwidth.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER fourMegabit(1), sixteenMegabit(2)  

ol52nnMFRModDipRingSpeed 1.3.6.1.4.1.49.2.3.1.4.4.20.1.1.3
The dip switch setting for the ring's bandwidth.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER fourMegabit(1), sixteenMegabit(2)  

ol52nnMFRPortTable 1.3.6.1.4.1.49.2.3.1.4.4.20.2
A table of port-specific information for each port of this module type.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Ol52nnMFRPortEntry

ol52nnMFRPortEntry 1.3.6.1.4.1.49.2.3.1.4.4.20.2.1
A description of 52nnM-FR port attributes.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Ol52nnMFRPortEntry  

ol52nnMFRPortSlotIndex 1.3.6.1.4.1.49.2.3.1.4.4.20.2.1.1
The slot number of this port's module.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ol52nnMFRPortIndex 1.3.6.1.4.1.49.2.3.1.4.4.20.2.1.2
The port number of this port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ol52nnMFRPortDipAdminState 1.3.6.1.4.1.49.2.3.1.4.4.20.2.1.3
The state of this port as indicated by the port's dip switches.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

ol52nnMFRPortCableImp 1.3.6.1.4.1.49.2.3.1.4.4.20.2.1.4
The setting of this port's impedance matching, with 100 ohm corresponding to unshielded twisted pair cabling and 150 ohm corresponding to shielded twisted pair cabling.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ohm100(1), ohm150(2)  

ol52nnMFRPortStationType 1.3.6.1.4.1.49.2.3.1.4.4.20.2.1.5
Determines whether the station connected to this port has a MAC address.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER mac-present(1), mac-not-present(2)  

ol52nnMFRTrunkTable 1.3.6.1.4.1.49.2.3.1.4.4.20.3
A list of trunk-specific information about each trunk for this module type.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Ol52nnMFRTrunkEntry

ol52nnMFRTrunkEntry 1.3.6.1.4.1.49.2.3.1.4.4.20.3.1
A description of 52nnM-FR trunk attributes.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Ol52nnMFRTrunkEntry  

ol52nnMFRTrunkSlotIndex 1.3.6.1.4.1.49.2.3.1.4.4.20.3.1.1
A unique value that identifies a particular module. Its value ranges between 1 and olModSlotNumber. The module identified by a particular value of this index is the same module as indentified by the same value of olTrunkSlotIndex.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ol52nnMFRTrunkIndex 1.3.6.1.4.1.49.2.3.1.4.4.20.3.1.2
The trunk number of this trunk.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ol52nnMFRTrunkDipAdminState 1.3.6.1.4.1.49.2.3.1.4.4.20.3.1.3
The state of this trunk as indicated by the trunk's dip switches.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

ol52nnMFRTrunkCableMon 1.3.6.1.4.1.49.2.3.1.4.4.20.3.1.4
The cable monitor configuration for this trunk. This does not apply to fiber trunks.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2), notApplicable(3)  

ol52nnMFRTrunkDipCableMon 1.3.6.1.4.1.49.2.3.1.4.4.20.3.1.5
The cable monitor configuration as indicated by this trunk's dip switches. This does not apply to fiber trunks.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2), notApplicable(3)  

ol52nnMFRTrunkCompMode 1.3.6.1.4.1.49.2.3.1.4.4.20.3.1.6
The compatibility mode for this trunk. This only applies to fiber trunks.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2), notApplicable(3)  

ol52nnMFRTrunkDipCompMode 1.3.6.1.4.1.49.2.3.1.4.4.20.3.1.7
The compatibility mode as indicated by this trunk's dip switches. This only applies to fiber trunks.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2), notApplicable(3)  

ol52nnMFRTrunkNetMapState 1.3.6.1.4.1.49.2.3.1.4.4.20.3.1.8
The map state of the copper ring-in trunk. This should be set to external for ring-in trunks which connect to external hubs. The mapping logic will not operate on trunks which are set to external. This prevents incorrect mapping which can occur when a module in one hub detects the mapping signal from another hub. This attribute only applies to copper ring-in trunks.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), internal(2), external(3)  

ol52nnMFRTrunkExtBcnRecovery 1.3.6.1.4.1.49.2.3.1.4.4.20.3.1.9
Indicates whether the trunk is connected to a segment that will perform beacon recovery. This should be set to exists(1) for trunks which connect to hubs which perform beacon recovery. This attribute is used to determine the fault domain when resolving a beaconing condition. The beacon recovery process will resolve beaconing on trunks with this attribute set to nonExists(2) before trunks with the attribute set to exists(1) are resolved. For backplane trunks, setting to a value other than notApplicable will return invalidData error. The default value is nonExists(2).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER exists(1), nonExists(2), notApplicable(3)  

ol52nnMFRTrunkBuddySlot 1.3.6.1.4.1.49.2.3.1.4.4.20.3.1.10
The slot index of the redundant trunk's buddy. To set a trunk to be redundant, the buddy's slot must be set to a valid value. This object is applicable to fiber trunks only. This value is only considered valid if the corresponding TrunkAdminState object for this trunk is configured for redundancy. Copper and backplane trunks will return invdata(6). If both the ring-in and ring-out trunks of a module are configured for redundancy, they must both be redundant to the same module. The buddy slot object for this slot is automatically set to this trunk.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

ol52nnMFRTrunkAdminState 1.3.6.1.4.1.49.2.3.1.4.4.20.3.1.11
The desired state of this trunk. Enabling a trunk allows the trunk to pass network traffic. This object may be used to configure fiber trunk redundancy. Setting a trunk to be redundant-primary(3) or redundant-backup(4) requires that the ol52nnMFRTrunkBuddySlot object be set to a valid value. If fiber trunk redundancy is already configured, setting this object to a redundant state will remove the previous configuration.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2), redundant-primary(3), redundant-standby(4)  

ol51nnMTSModTable 1.3.6.1.4.1.49.2.3.1.4.4.21.1
A table of module-specific information for each 51nnM-TS module in the concentrator.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Ol51nnMTSModEntry

ol51nnMTSModEntry 1.3.6.1.4.1.49.2.3.1.4.4.21.1.1
A list of module information for each 51nnM-TS module in the concentrator.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Ol51nnMTSModEntry  

ol51nnMTSModSlotIndex 1.3.6.1.4.1.49.2.3.1.4.4.21.1.1.1
The slot number of this module.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ol51nnMTSModProtocols 1.3.6.1.4.1.49.2.3.1.4.4.21.1.1.2
A textual description of the protocols supported by this module
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

ol51nnMTSModIpAddress 1.3.6.1.4.1.49.2.3.1.4.4.21.1.1.3
The IP Address of the terminal server.
Status: mandatory Access: read-only
OBJECT-TYPE    
  IpAddress  

ol51nnMTSModTCPPort 1.3.6.1.4.1.49.2.3.1.4.4.21.1.1.4
The TCP port number of the the terminal server's remote console port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ol51nnMTSModStationAddr 1.3.6.1.4.1.49.2.3.1.4.4.21.1.1.5
A 6 octet address that uniquely identifies this module. The station address is the mac address of the terminal server.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(6)  

ol51nnMTSModDipNetwork 1.3.6.1.4.1.49.2.3.1.4.4.21.1.1.6
The network indicated by the module's dip switches.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER isolated(2), ethernet-1(6), ethernet-2(7), ethernet-3(8)  

ol51nnMTSModCPURev 1.3.6.1.4.1.49.2.3.1.4.4.21.1.1.7
The terminal server's CPU revision.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(1..10)  

ol51nnMTSPortTable 1.3.6.1.4.1.49.2.3.1.4.4.21.2
A table of information that contains port-specific information for each port on each 51nnM-TS module.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Ol51nnMTSPortEntry

ol51nnMTSPortEntry 1.3.6.1.4.1.49.2.3.1.4.4.21.2.1
A list of information about a specific port on a 51nnM-TS module.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Ol51nnMTSPortEntry  

ol51nnMTSPortSlotIndex 1.3.6.1.4.1.49.2.3.1.4.4.21.2.1.1
The slot number for this port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ol51nnMTSPortIndex 1.3.6.1.4.1.49.2.3.1.4.4.21.2.1.2
The port number of this port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ol51nnMTSPortAdminState 1.3.6.1.4.1.49.2.3.1.4.4.21.2.1.3
The administrative state of this port.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2), local(6), remote(7)  

ol51nnMTSPortOperState 1.3.6.1.4.1.49.2.3.1.4.4.21.2.1.4
The operational mode of this port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER idle(1), local(2), connected(3)  

ol51nnMFLModTable 1.3.6.1.4.1.49.2.3.1.4.4.22.1
A table of module-specific information for each 51nnM-FL module in the concentrator.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Ol51nnMFLModEntry

ol51nnMFLModEntry 1.3.6.1.4.1.49.2.3.1.4.4.22.1.1
A list of module-specific information associated with a particular 51nnM-FL module in the concentrator.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Ol51nnMFLModEntry  

ol51nnMFLModSlotIndex 1.3.6.1.4.1.49.2.3.1.4.4.22.1.1.1
The slot number of this module.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ol51nnMFLModDipNetwork 1.3.6.1.4.1.49.2.3.1.4.4.22.1.1.2
The network indicated by the module's dip switches.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER isolated(2), ethernet-1(6), ethernet-2(7), ethernet-3(8)  

ol51nnMFLPortTable 1.3.6.1.4.1.49.2.3.1.4.4.22.2
A table of port-specific information for each port of each 51nnM-FL module.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Ol51nnMFLPortEntry

ol51nnMFLPortEntry 1.3.6.1.4.1.49.2.3.1.4.4.22.2.1
A list of information about a specific port on a 51nnM-FL module.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Ol51nnMFLPortEntry  

ol51nnMFLPortSlotIndex 1.3.6.1.4.1.49.2.3.1.4.4.22.2.1.1
A unique value that identifies a particular module. Its value ranges between 1 and olModSlotNumber. The module identified by a particular value of this index is the same module as indentified by the same value of olPortSlotIndex.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ol51nnMFLPortIndex 1.3.6.1.4.1.49.2.3.1.4.4.22.2.1.2
The port number of this port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ol51nnMFLPortAdminState 1.3.6.1.4.1.49.2.3.1.4.4.22.2.1.3
The desired state of this port. Setting this port to be redundant with invalid settings of buddy slot and buddy port will return invalidData error. Remote Failure Signaling (RFS), is set on connected module port to permit transmit error detection on local port. Port must be set to be RFS when connected port is set to be redundant
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2), redundant-primary(3), redundant-backup(4), redundant-rfs(5)  

ol51nnMFLPortBuddySlot 1.3.6.1.4.1.49.2.3.1.4.4.22.2.1.4
The slot index of the redundant port's buddy.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

ol51nnMFLPortBuddyPort 1.3.6.1.4.1.49.2.3.1.4.4.22.2.1.5
The port index of the redundant port's buddy.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

ol51nnMFLPortDipAdminState 1.3.6.1.4.1.49.2.3.1.4.4.22.2.1.6
The state of this port as indicated by the port's dip switches.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2), redundant-primary(3), redundant-backup(4), redundant-rfs(5)  

ol50nnMRCTLModTable 1.3.6.1.4.1.49.2.3.1.4.4.23.1
A table that contains information about each 50nnM-RCTL in the concentrator.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Ol50nnMRCTLModEntry

ol50nnMRCTLModEntry 1.3.6.1.4.1.49.2.3.1.4.4.23.1.1
A list of information for each 50nnM-RCTL module in the concentrator.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Ol50nnMRCTLModEntry  

ol50nnMRCTLModSlotIndex 1.3.6.1.4.1.49.2.3.1.4.4.23.1.1.1
The slot number for this module.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ol50nnMRCTLModOperState 1.3.6.1.4.1.49.2.3.1.4.4.23.1.1.2
The operational state of the 50nnM-RCTL module. Specifically, this is an indicator of whether the 50nnM-RCTL module is providing clock signals to the backplane. An active 50nnM-RCTL module provides clock signals to the backplane while a standby 50nnM-RCTL module does not. Note that only one 50nnM-RCTL module will be active at any given time; all other 50nnM-RCTL modules in the concentrator will be in standby mode.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER active(1), standby(2)  

ol50nnMRCTLModClockStatus 1.3.6.1.4.1.49.2.3.1.4.4.23.1.1.3
The current status of the on-board clocks on this module.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER okay(1), faulty(2)  

ol50nnMRCTLModTempStatus 1.3.6.1.4.1.49.2.3.1.4.4.23.1.1.4
The temperature as detected by the probe on this module.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER okay(1), extremeTemp(2)  

ol51nnMFBModTable 1.3.6.1.4.1.49.2.3.1.4.4.24.1
A list of module-specific information associated with a particular 51nnM-FB module in the concentrator.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Ol51nnMFBModEntry

ol51nnMFBModEntry 1.3.6.1.4.1.49.2.3.1.4.4.24.1.1
A list of module-specific information about a specific 51nnM-FB module in the concentrator.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Ol51nnMFBModEntry  

ol51nnMFBModSlotIndex 1.3.6.1.4.1.49.2.3.1.4.4.24.1.1.1
The slot number of this module.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ol51nnMFBModDipNetwork 1.3.6.1.4.1.49.2.3.1.4.4.24.1.1.2
The network indicated by the module's dip switches.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER isolated(2), ethernet-1(6), ethernet-2(7), ethernet-3(8)  

ol51nnMFBModLLW 1.3.6.1.4.1.49.2.3.1.4.4.24.1.1.3
The current state of this module's low light warning configuration. Enabling this feature causes the module to check for low light and to issue a warning if low light is present. Disabling low light has the advantage of faster redundancy switchover in the event of a port error.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

ol51nnMFBModDipLLW 1.3.6.1.4.1.49.2.3.1.4.4.24.1.1.4
The low light warning configuration indicated by this module's dip switches.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

ol51nnMFBPortTable 1.3.6.1.4.1.49.2.3.1.4.4.24.2
A table of port-specific information for each port of this module type.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Ol51nnMFBPortEntry

ol51nnMFBPortEntry 1.3.6.1.4.1.49.2.3.1.4.4.24.2.1
A list of module-specific information about a specific 51nnM-FB port in the concentrator.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Ol51nnMFBPortEntry  

ol51nnMFBPortSlotIndex 1.3.6.1.4.1.49.2.3.1.4.4.24.2.1.1
The slot number of this port's module.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ol51nnMFBPortIndex 1.3.6.1.4.1.49.2.3.1.4.4.24.2.1.2
The port number of this port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ol51nnMFBPortAdminState 1.3.6.1.4.1.49.2.3.1.4.4.24.2.1.3
The desired state of this port. Setting this port to be redundant with invalid settings of buddy slot and buddy port will return the genError error.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2), redundant-primary(3), redundant-backup(4)  

ol51nnMFBPortBuddySlot 1.3.6.1.4.1.49.2.3.1.4.4.24.2.1.4
The slot index of the redundant port's buddy. To set a port to be redundant, the buddy's slot and port must be set to valid values. The buddy is automatically set to be redundant to this port.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

ol51nnMFBPortBuddyPort 1.3.6.1.4.1.49.2.3.1.4.4.24.2.1.5
The port index of the redundant port's buddy. To set a port to be redundant, the buddy's slot and port must be set to valid values. The buddy is automatically set to be redundant to this port.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

ol51nnMFBPortDipAdminState 1.3.6.1.4.1.49.2.3.1.4.4.24.2.1.6
The state of this port as indicated by the port's dip switches.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

ol53nnMFBMICModTable 1.3.6.1.4.1.49.2.3.1.4.4.26.1
A list of module attributes that apply to this model. To access an ol53nnMFBMICModTable entry, the ol53nnMFBMICModSlotIndex attribute is used.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Ol53nnMFBMICModEntry

ol53nnMFBMICModEntry 1.3.6.1.4.1.49.2.3.1.4.4.26.1.1
A list of module-specific information about a specific 53nnM-FBMIC module in the concentrator.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Ol53nnMFBMICModEntry  

ol53nnMFBMICModSlotIndex 1.3.6.1.4.1.49.2.3.1.4.4.26.1.1.1
A unique value that identifies a particular module. Its value ranges between 1 and olModSlotNumber. The module identified by a particular value of this index is the same module as indentified by the same value of olModSlotIndex.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ol53nnMFBMICModDownStreamModule 1.3.6.1.4.1.49.2.3.1.4.4.26.1.1.2
Down stream slot (transmit to)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..16  

ol53nnMFBMICModUpStreamModule 1.3.6.1.4.1.49.2.3.1.4.4.26.1.1.3
Up stream slot (receive from)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..16  

ol53nnMFBMICModDownStreamOperPath 1.3.6.1.4.1.49.2.3.1.4.4.26.1.1.4
Transmit DBA (debug only)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER isolated(2), fddi-path-1(24), fddi-path-2(25), fddi-path-3(26), fddi-path-4(27), fddi-path-5(28), fddi-path-6(29), fddi-path-7(30), fddi-path-8(31)  

ol53nnMFBMICModUpStreamOperPath 1.3.6.1.4.1.49.2.3.1.4.4.26.1.1.5
Receive DBA (debug only)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER isolated(2), fddi-path-1(24), fddi-path-2(25), fddi-path-3(26), fddi-path-4(27), fddi-path-5(28), fddi-path-6(29), fddi-path-7(30), fddi-path-8(31)  

ol53nnMFBMICModRingInfo 1.3.6.1.4.1.49.2.3.1.4.4.26.1.1.6
An array which is indexed by DBA number. Each element contains the slot number (1..16) which is assigned to transmit on this DBA. (debug only)
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(1..8)  

ol53nnMFBMICPortTable 1.3.6.1.4.1.49.2.3.1.4.4.26.2
A table of port-specific information for each port of this module type.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Ol53nnMFBMICPortEntry

ol53nnMFBMICPortEntry 1.3.6.1.4.1.49.2.3.1.4.4.26.2.1
A list of module-specific information about a specific 53nnM-FBMIC port in the concentrator.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Ol53nnMFBMICPortEntry  

ol53nnMFBMICPortSlotIndex 1.3.6.1.4.1.49.2.3.1.4.4.26.2.1.1
A unique value that identifies a particular module. Its value ranges between 1 and olModSlotNumber. The module identified by a particular value of this index is the same module as indentified by the same value of olPortSlotIndex.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ol53nnMFBMICPortIndex 1.3.6.1.4.1.49.2.3.1.4.4.26.2.1.2
A unique value that identifies a particular port within this module. Its value ranges between 1 and olModPortNumber. The module identified by a particular value of this index is the same module as indentified by the same value of olPortIndex.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ol53nnMFBMICPortConfig 1.3.6.1.4.1.49.2.3.1.4.4.26.2.1.3
Specifies the FDDI port type. If the port is on an FFM, the only allowed values are slave(3), and master(4). In addition, there can only be one active slave port on any concentrator FDDI network.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER slave(3), master(4)  

ol53nnMFBMICPortPcmState 1.3.6.1.4.1.49.2.3.1.4.4.26.2.1.4
(refer to ANSI SMT 9.6.2).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER pc0(1), pc1(2), pc2(3), pc3(4), pc4(5), pc5(6), pc6(7), pc7(8), pc8(9), pc9(10)  

ol53nnMFBMICPortConnectState 1.3.6.1.4.1.49.2.3.1.4.4.26.2.1.5
An indication of the connect state of this PORT. Basically, this gives a higher level view of the state of the connection by grouping PCM states and the PC-Withhold flag state. The supported values and their corresponding PCM states and PC-Withhold condition, when relevant, are: disabled: (PC0:Off, PC9:Maint) connecting: (PC1(Break) || PC3 (Connect) || PC4(next) || PC5 (Signal) || PC6(Join) || PC7 (Verify)) && (PC-Withhold = None) standby: (PC-Withhold != None) active: (PC2:Trace || PC8:Active)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER disabled(1), connecting(2), standby(3), active(4)  

ol53nnMFBMICPortNeighbor 1.3.6.1.4.1.49.2.3.1.4.4.26.2.1.6
The type (PC-Neighbor) of the remote PORT that is determined in PC-Signaling in R-Val (1,2) (refer to ANSI SMT 9.6.3.2).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER a(1), b(2), slave(3), master(4), unknown(5)  

ol53nnMFBMICPortRemoteMACIndicated 1.3.6.1.4.1.49.2.3.1.4.4.26.2.1.7
The indication, in PC-Signaling that the remote partner intends to place a MAC in the output token PATH of this PORT. Signaled as R-Val (9) (refer to ANSI SMT 9.6.3.2).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER true(1), false(2)  

ol53nnMFBMICPortBSFlag 1.3.6.1.4.1.49.2.3.1.4.4.26.2.1.8
The Break State, BS-Flag (refer to ANSI SMT 9.4.3.4).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER true(1), false(2)  

ol53nnMFBMICPortPCWithhold 1.3.6.1.4.1.49.2.3.1.4.4.26.2.1.9
PC-Withhold, (refer to ANSI SMT 9.4.1).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER none(1), m-m(2), other(3)  

ol53nnMFBMICPortLerCondition 1.3.6.1.4.1.49.2.3.1.4.4.26.2.1.10
This variable is set to true whenever LerEstimate is less than or equal to LerAlarm (the larger the number the smaller the value).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER bad(1), okay(2)  

ol53nnMFBMICTrunkTable 1.3.6.1.4.1.49.2.3.1.4.4.26.3
FDDI module specific trunk table variables. At present there are none.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Ol53nnMFBMICTrunkEntry

ol53nnMFBMICTrunkEntry 1.3.6.1.4.1.49.2.3.1.4.4.26.3.1
A description of 53nnM-FBMIC trunk attributes.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Ol53nnMFBMICTrunkEntry  

ol53nnMFBMICTrunkSlotIndex 1.3.6.1.4.1.49.2.3.1.4.4.26.3.1.1
A unique value that identifies a particular module. Its value ranges between 1 and olModSlotNumber. The module identified by a particular value of this index is the same module as indentified by the same value of olTrunkSlotIndex.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ol53nnMFBMICTrunkIndex 1.3.6.1.4.1.49.2.3.1.4.4.26.3.1.2
A unique value that identifies a particular trunk within this module. Its value ranges between 1 and olModTrunkNumber. The module identified by a particular value of this index is the same module as indentified by the same value of olTrunkIndex.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ol53nnMFIBSTModTable 1.3.6.1.4.1.49.2.3.1.4.4.27.1
A list of module attributes that apply to this model. To access an ol53nnMFIBSTModTable entry, the ol53nnMFIBSTModSlotIndex attribute is used.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Ol53nnMFIBSTModEntry

ol53nnMFIBSTModEntry 1.3.6.1.4.1.49.2.3.1.4.4.27.1.1
A list of module-specific information about a specific 53nnM-FIBST module in the concentrator.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Ol53nnMFIBSTModEntry  

ol53nnMFIBSTModSlotIndex 1.3.6.1.4.1.49.2.3.1.4.4.27.1.1.1
A unique value that identifies a particular module. Its value ranges between 1 and olModSlotNumber. The module identified by a particular value of this index is the same module as indentified by the same value of olModSlotIndex.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ol53nnMFIBSTModDownStreamModule 1.3.6.1.4.1.49.2.3.1.4.4.27.1.1.2
Down stream slot (transmit to)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..16  

ol53nnMFIBSTModUpStreamModule 1.3.6.1.4.1.49.2.3.1.4.4.27.1.1.3
Up stream slot (receive from)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..16  

ol53nnMFIBSTModDownStreamOperPath 1.3.6.1.4.1.49.2.3.1.4.4.27.1.1.4
Transmit DBA (debug only)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER isolated(2), fddi-path-1(24), fddi-path-2(25), fddi-path-3(26), fddi-path-4(27), fddi-path-5(28), fddi-path-6(29), fddi-path-7(30), fddi-path-8(31)  

ol53nnMFIBSTModUpStreamOperPath 1.3.6.1.4.1.49.2.3.1.4.4.27.1.1.5
Receive DBA (debug only)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER isolated(2), fddi-path-1(24), fddi-path-2(25), fddi-path-3(26), fddi-path-4(27), fddi-path-5(28), fddi-path-6(29), fddi-path-7(30), fddi-path-8(31)  

ol53nnMFIBSTModRingInfo 1.3.6.1.4.1.49.2.3.1.4.4.27.1.1.6
An array which is indexed by DBA number. Each element contains the slot number (1..16) which is assigned to transmit on this DBA. (debug only)
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(1..8)  

ol53nnMFIBSTPortTable 1.3.6.1.4.1.49.2.3.1.4.4.27.2
A table of port-specific information for each port of this module type.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Ol53nnMFIBSTPortEntry

ol53nnMFIBSTPortEntry 1.3.6.1.4.1.49.2.3.1.4.4.27.2.1
A list of module-specific information about a specific 53nnM-FIBST port in the concentrator.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Ol53nnMFIBSTPortEntry  

ol53nnMFIBSTPortSlotIndex 1.3.6.1.4.1.49.2.3.1.4.4.27.2.1.1
A unique value that identifies a particular module. Its value ranges between 1 and olModSlotNumber. The module identified by a particular value of this index is the same module as indentified by the same value of olPortSlotIndex.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ol53nnMFIBSTPortIndex 1.3.6.1.4.1.49.2.3.1.4.4.27.2.1.2
A unique value that identifies a particular port within this module. Its value ranges between 1 and olModPortNumber. The module identified by a particular value of this index is the same module as indentified by the same value of olPortIndex.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ol53nnMFIBSTPortConfig 1.3.6.1.4.1.49.2.3.1.4.4.27.2.1.3
Specifies the FDDI port type. If the port is on an FFM, the only allowed values are slave(3) and master(4). In addition, there can only be one active slave port on any concentrator FDDI network.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER slave(3), master(4)  

ol53nnMFIBSTPortPcmState 1.3.6.1.4.1.49.2.3.1.4.4.27.2.1.4
(refer to ANSI SMT 9.6.2).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER pc0(1), pc1(2), pc2(3), pc3(4), pc4(5), pc5(6), pc6(7), pc7(8), pc8(9), pc9(10)  

ol53nnMFIBSTPortConnectState 1.3.6.1.4.1.49.2.3.1.4.4.27.2.1.5
An indication of the connect state of this PORT. Basically, this gives a higher level view of the state of the connection by grouping PCM states and the PC-Withhold flag state. The supported values and their corresponding PCM states and PC-Withhold condition, when relevant, are: disabled: (PC0:Off, PC9:Maint) connecting: (PC1(Break) || PC3 (Connect) || PC4(next) || PC5 (Signal) || PC6(Join) || PC7 (Verify)) && (PC-Withhold = None) standby: (PC-Withhold != None) active: (PC2:Trace || PC8:Active)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER disabled(1), connecting(2), standby(3), active(4)  

ol53nnMFIBSTPortNeighbor 1.3.6.1.4.1.49.2.3.1.4.4.27.2.1.6
The type (PC-Neighbor) of the remote PORT that is determined in PC-Signaling in R-Val (1,2) (refer to ANSI SMT 9.6.3.2).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER a(1), b(2), slave(3), master(4), unknown(5)  

ol53nnMFIBSTPortRemoteMACIndicated 1.3.6.1.4.1.49.2.3.1.4.4.27.2.1.7
The indication, in PC-Signaling that the remote partner intends to place a MAC in the output token PATH of this PORT. Signaled as R-Val (9) (refer to ANSI SMT 9.6.3.2).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER true(1), false(2)  

ol53nnMFIBSTPortBSFlag 1.3.6.1.4.1.49.2.3.1.4.4.27.2.1.8
The Break State, BS-Flag (refer to ANSI SMT 9.4.3.4).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER true(1), false(2)  

ol53nnMFIBSTPortPCWithhold 1.3.6.1.4.1.49.2.3.1.4.4.27.2.1.9
PC-Withhold, (refer to ANSI SMT 9.4.1).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER none(1), m-m(2), other(3)  

ol53nnMFIBSTPortLerCondition 1.3.6.1.4.1.49.2.3.1.4.4.27.2.1.10
This variable is set to true whenever LerEstimate is less than or equal to LerAlarm (the larger the number the smaller the value).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER bad(1), okay(2)  

ol53nnMFIBSTTrunkTable 1.3.6.1.4.1.49.2.3.1.4.4.27.3
FDDI module specific trunk table variables. At present there are none.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Ol53nnMFIBSTTrunkEntry

ol53nnMFIBSTTrunkEntry 1.3.6.1.4.1.49.2.3.1.4.4.27.3.1
A description of 53nnM-FIBST trunk attributes.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Ol53nnMFIBSTTrunkEntry  

ol53nnMFIBSTTrunkSlotIndex 1.3.6.1.4.1.49.2.3.1.4.4.27.3.1.1
A unique value that identifies a particular module. Its value ranges between 1 and olModSlotNumber. The module identified by a particular value of this index is the same module as indentified by the same value of olTrunkSlotIndex.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ol53nnMFIBSTTrunkIndex 1.3.6.1.4.1.49.2.3.1.4.4.27.3.1.2
A unique value that identifies a particular trunk within this module. Its value ranges between 1 and olModTrunkNumber. The module identified by a particular value of this index is the same module as indentified by the same value of olTrunkIndex.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ol53nnMSTPModTable 1.3.6.1.4.1.49.2.3.1.4.4.28.1
A list of module attributes that apply to this model. To access an ol53nnMSTPModTable entry, the ol53nnMSTPModSlotIndex attribute is used.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Ol53nnMSTPModEntry

ol53nnMSTPModEntry 1.3.6.1.4.1.49.2.3.1.4.4.28.1.1
A list of module-specific information about a specific 53nnM-STP module in the concentrator.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Ol53nnMSTPModEntry  

ol53nnMSTPModSlotIndex 1.3.6.1.4.1.49.2.3.1.4.4.28.1.1.1
A unique value that identifies a particular module. Its value ranges between 1 and olModSlotNumber. The module identified by a particular value of this index is the same module as indentified by the same value of olModSlotIndex.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ol53nnMSTPModDownStreamModule 1.3.6.1.4.1.49.2.3.1.4.4.28.1.1.2
Down stream slot (transmit to)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..16  

ol53nnMSTPModUpStreamModule 1.3.6.1.4.1.49.2.3.1.4.4.28.1.1.3
Down stream slot (receive from)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..16  

ol53nnMSTPModDownStreamOperPath 1.3.6.1.4.1.49.2.3.1.4.4.28.1.1.4
transmit DBA (debug only)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER isolated(2), fddi-path-1(24), fddi-path-2(25), fddi-path-3(26), fddi-path-4(27), fddi-path-5(28), fddi-path-6(29), fddi-path-7(30), fddi-path-8(31)  

ol53nnMSTPModUpStreamOperPath 1.3.6.1.4.1.49.2.3.1.4.4.28.1.1.5
receive DBA (debug only)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER isolated(2), fddi-path-1(24), fddi-path-2(25), fddi-path-3(26), fddi-path-4(27), fddi-path-5(28), fddi-path-6(29), fddi-path-7(30), fddi-path-8(31)  

ol53nnMSTPModRingInfo 1.3.6.1.4.1.49.2.3.1.4.4.28.1.1.6
An array which is indexed by DBA number. Each element contains the slot number (1..16) which is assigned to transmit on this DBA. (debug only)
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(1..8)  

ol53nnMSTPPortTable 1.3.6.1.4.1.49.2.3.1.4.4.28.2
A table of port-specific information for each port of this module type.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Ol53nnMSTPPortEntry

ol53nnMSTPPortEntry 1.3.6.1.4.1.49.2.3.1.4.4.28.2.1
A list of module-specific information about a specific 53nnM-STP port in the concentrator.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Ol53nnMSTPPortEntry  

ol53nnMSTPPortSlotIndex 1.3.6.1.4.1.49.2.3.1.4.4.28.2.1.1
A unique value that identifies a particular module. Its value ranges between 1 and olModSlotNumber. The module identified by a particular value of this index is the same module as indentified by the same value of olPortSlotIndex.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ol53nnMSTPPortIndex 1.3.6.1.4.1.49.2.3.1.4.4.28.2.1.2
A unique value that identifies a particular port within this module. Its value ranges between 1 and olModPortNumber. The module identified by a particular value of this index is the same module as indentified by the same value of olPortIndex.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ol53nnMSTPPortConfig 1.3.6.1.4.1.49.2.3.1.4.4.28.2.1.3
Specifies the FDDI port type. If the port is on an FFM, the only allowed values are slave(3) and master(4). In addition, there can only be one active slave port on any concentrator FDDI network.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER slave(3), master(4)  

ol53nnMSTPPortPcmState 1.3.6.1.4.1.49.2.3.1.4.4.28.2.1.4
(refer to ANSI SMT 9.6.2).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER pc0(1), pc1(2), pc2(3), pc3(4), pc4(5), pc5(6), pc6(7), pc7(8), pc8(9), pc9(10)  

ol53nnMSTPPortConnectState 1.3.6.1.4.1.49.2.3.1.4.4.28.2.1.5
An indication of the connect state of this PORT. Basically, this gives a higher level view of the state of the connection by grouping PCM states and the PC-Withhold flag state. The supported values and their corresponding PCM states and PC-Withhold condition, when relevant, are: disabled: (PC0:Off, PC9:Maint) connecting: (PC1(Break) || PC3 (Connect) || PC4(next) || PC5 (Signal) || PC6(Join) || PC7 (Verify)) && (PC-Withhold = None) standby: (PC-Withhold != None) active: (PC2:Trace || PC8:Active)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER disabled(1), connecting(2), standby(3), active(4)  

ol53nnMSTPPortNeighbor 1.3.6.1.4.1.49.2.3.1.4.4.28.2.1.6
The type (PC-Neighbor) of the remote PORT that is determined in PC-Signaling in R-Val (1,2) (refer to ANSI SMT 9.6.3.2).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER a(1), b(2), slave(3), master(4), unknown(5)  

ol53nnMSTPPortRemoteMACIndicated 1.3.6.1.4.1.49.2.3.1.4.4.28.2.1.7
The indication, in PC-Signaling that the remote partner intends to place a MAC in the output token PATH of this PORT. Signaled as R-Val (9) (refer to ANSI SMT 9.6.3.2).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER true(1), false(2)  

ol53nnMSTPPortBSFlag 1.3.6.1.4.1.49.2.3.1.4.4.28.2.1.8
The Break State, BS-Flag (refer to ANSI SMT 9.4.3.4).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER true(1), false(2)  

ol53nnMSTPPortPCWithhold 1.3.6.1.4.1.49.2.3.1.4.4.28.2.1.9
PC-Withhold, (refer to ANSI SMT 9.4.1).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER none(1), m-m(2), other(3)  

ol53nnMSTPPortLerCondition 1.3.6.1.4.1.49.2.3.1.4.4.28.2.1.10
This variable is set to true whenever LerEstimate is less than or equal to LerAlarm (the larger the number the smaller the value).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER bad(1), okay(2)  

ol53nnMSTPPortPersonality 1.3.6.1.4.1.49.2.3.1.4.4.28.2.1.11
Specifies the physical signaling used by the port, the only valid values are sddi(3) and tpddi(4).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER sddi(1), tpddi(2)  

ol53nnMSTPTrunkTable 1.3.6.1.4.1.49.2.3.1.4.4.28.3
FDDI module specific trunk table variables. At present there are none.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Ol53nnMSTPTrunkEntry

ol53nnMSTPTrunkEntry 1.3.6.1.4.1.49.2.3.1.4.4.28.3.1
A description of 53nnM-STP trunk attributes.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Ol53nnMSTPTrunkEntry  

ol53nnMSTPTrunkSlotIndex 1.3.6.1.4.1.49.2.3.1.4.4.28.3.1.1
A unique value that identifies a particular module. Its value ranges between 1 and olModSlotNumber. The module identified by a particular value of this index is the same module as indentified by the same value of olTrunkSlotIndex.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ol53nnMSTPTrunkIndex 1.3.6.1.4.1.49.2.3.1.4.4.28.3.1.2
A unique value that identifies a particular trunk within this module. Its value ranges between 1 and olModTrunkNumber. The module identified by a particular value of this index is the same module as indentified by the same value of olTrunkIndex.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ol53nnMTDDIModTable 1.3.6.1.4.1.49.2.3.1.4.4.65.1
A list of module attributes that apply to this model. To access an ol53nnMTDDIModTable entry, the ol53nnMTDDIModSlotIndex attribute is used.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Ol53nnMTDDIModEntry

ol53nnMTDDIModEntry 1.3.6.1.4.1.49.2.3.1.4.4.65.1.1
A list of module-specific information about a specific 53nnM-TDDI module in the concentrator.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Ol53nnMTDDIModEntry  

ol53nnMTDDIModSlotIndex 1.3.6.1.4.1.49.2.3.1.4.4.65.1.1.1
A unique value that identifies a particular module. Its value ranges between 1 and olModSlotNumber. The module identified by a particular value of this index is the same module as indentified by the same value of olModSlotIndex.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ol53nnMTDDIModDownStreamModule 1.3.6.1.4.1.49.2.3.1.4.4.65.1.1.2
Down stream slot (transmit to)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..16  

ol53nnMTDDIModUpStreamModule 1.3.6.1.4.1.49.2.3.1.4.4.65.1.1.3
Down stream slot (receive from)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..16  

ol53nnMTDDIModDownStreamOperPath 1.3.6.1.4.1.49.2.3.1.4.4.65.1.1.4
transmit DBA (debug only)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER isolated(2), fddi-path-1(24), fddi-path-2(25), fddi-path-3(26), fddi-path-4(27), fddi-path-5(28), fddi-path-6(29), fddi-path-7(30), fddi-path-8(31)  

ol53nnMTDDIModUpStreamOperPath 1.3.6.1.4.1.49.2.3.1.4.4.65.1.1.5
receive DBA (debug only)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER isolated(2), fddi-path-1(24), fddi-path-2(25), fddi-path-3(26), fddi-path-4(27), fddi-path-5(28), fddi-path-6(29), fddi-path-7(30), fddi-path-8(31)  

ol53nnMTDDIModRingInfo 1.3.6.1.4.1.49.2.3.1.4.4.65.1.1.6
An array which is indexed by DBA number. Each element contains the slot number (1..16) which is assigned to transmit on this DBA. (debug only)
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(1..8)  

ol53nnMTDDIPortTable 1.3.6.1.4.1.49.2.3.1.4.4.65.2
A table of port-specific information for each port of this module type.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Ol53nnMTDDIPortEntry

ol53nnMTDDIPortEntry 1.3.6.1.4.1.49.2.3.1.4.4.65.2.1
A list of module-specific information about a specific 53nnM-TDDI port in the concentrator.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Ol53nnMTDDIPortEntry  

ol53nnMTDDIPortSlotIndex 1.3.6.1.4.1.49.2.3.1.4.4.65.2.1.1
A unique value that identifies a particular module. Its value ranges between 1 and olModSlotNumber. The module identified by a particular value of this index is the same module as indentified by the same value of olPortSlotIndex.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ol53nnMTDDIPortIndex 1.3.6.1.4.1.49.2.3.1.4.4.65.2.1.2
A unique value that identifies a particular port within this module. Its value ranges between 1 and olModPortNumber. The module identified by a particular value of this index is the same module as indentified by the same value of olPortIndex.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ol53nnMTDDIPortConfig 1.3.6.1.4.1.49.2.3.1.4.4.65.2.1.3
Specifies the FDDI port type. If the port is on an FFM, the only allowed values are slave(3) and master(4). In addition, there can only be one active slave port on any concentrator FDDI network.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER slave(3), master(4)  

ol53nnMTDDIPortPcmState 1.3.6.1.4.1.49.2.3.1.4.4.65.2.1.4
(refer to ANSI SMT 9.6.2).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER pc0(1), pc1(2), pc2(3), pc3(4), pc4(5), pc5(6), pc6(7), pc7(8), pc8(9), pc9(10)  

ol53nnMTDDIPortConnectState 1.3.6.1.4.1.49.2.3.1.4.4.65.2.1.5
An indication of the connect state of this PORT. Basically, this gives a higher level view of the state of the connection by grouping PCM states and the PC-Withhold flag state. The supported values and their corresponding PCM states and PC-Withhold condition, when relevant, are: disabled: (PC0:Off, PC9:Maint) connecting: (PC1(Break) || PC3 (Connect) || PC4(next) || PC5 (Signal) || PC6(Join) || PC7 (Verify)) && (PC-Withhold = None) standby: (PC-Withhold != None) active: (PC2:Trace || PC8:Active)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER disabled(1), connecting(2), standby(3), active(4)  

ol53nnMTDDIPortNeighbor 1.3.6.1.4.1.49.2.3.1.4.4.65.2.1.6
The type (PC-Neighbor) of the remote PORT that is determined in PC-Signaling in R-Val (1,2) (refer to ANSI SMT 9.6.3.2).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER a(1), b(2), slave(3), master(4), unknown(5)  

ol53nnMTDDIPortRemoteMACIndicated 1.3.6.1.4.1.49.2.3.1.4.4.65.2.1.7
The indication, in PC-Signaling that the remote partner intends to place a MAC in the output token PATH of this PORT. Signaled as R-Val (9) (refer to ANSI SMT 9.6.3.2).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER true(1), false(2)  

ol53nnMTDDIPortBSFlag 1.3.6.1.4.1.49.2.3.1.4.4.65.2.1.8
The Break State, BS-Flag (refer to ANSI SMT 9.4.3.4).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER true(1), false(2)  

ol53nnMTDDIPortPCWithhold 1.3.6.1.4.1.49.2.3.1.4.4.65.2.1.9
PC-Withhold, (refer to ANSI SMT 9.4.1).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER none(1), m-m(2), other(3)  

ol53nnMTDDIPortLerCondition 1.3.6.1.4.1.49.2.3.1.4.4.65.2.1.10
This variable is set to true whenever LerEstimate is less than or equal to LerAlarm (the larger the number the smaller the value).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER bad(1), okay(2)  

ol53nnMTDDITrunkTable 1.3.6.1.4.1.49.2.3.1.4.4.65.3
FDDI module specific trunk table variables. At present there are none.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Ol53nnMTDDITrunkEntry

ol53nnMTDDITrunkEntry 1.3.6.1.4.1.49.2.3.1.4.4.65.3.1
A description of 53nnM-TDDI trunk attributes.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Ol53nnMTDDITrunkEntry  

ol53nnMTDDITrunkSlotIndex 1.3.6.1.4.1.49.2.3.1.4.4.65.3.1.1
A unique value that identifies a particular module. Its value ranges between 1 and olModSlotNumber. The module identified by a particular value of this index is the same module as indentified by the same value of olTrunkSlotIndex.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ol53nnMTDDITrunkIndex 1.3.6.1.4.1.49.2.3.1.4.4.65.3.1.2
A unique value that identifies a particular trunk within this module. Its value ranges between 1 and olModTrunkNumber. The module identified by a particular value of this index is the same module as indentified by the same value of olTrunkIndex.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ol51nnMTPCLModTable 1.3.6.1.4.1.49.2.3.1.4.4.29.1
A list of module-specific information about a specific 51nnM-TPCL module in the concentrator.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Ol51nnMTPCLModEntry

ol51nnMTPCLModEntry 1.3.6.1.4.1.49.2.3.1.4.4.29.1.1
A list of module-specific information about a specific 51nnM-TPCL module in the concentrator.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Ol51nnMTPCLModEntry  

ol51nnMTPCLModSlotIndex 1.3.6.1.4.1.49.2.3.1.4.4.29.1.1.1
The slot number of this module.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ol51nnMTPCLModMonitorConn 1.3.6.1.4.1.49.2.3.1.4.4.29.1.1.2
When both connectors are on the same network: Setting this object to connector-1 allows the EMM to monitor the port statistics of port 1-12 on a per-port basis, and the port statistics of port 13-24 are summed and are reported through port 13. Setting this object to connector-2 allows the EMM to monitor the port statistics of port 12-24 on a per-port basis, and the port statistics of port 1-12 are summed and are reported through port 13. Note: when the 2 connectors are on different networks, setting this object to the value connector-1 or connector-2 will not have any effect. The port counters will be cleared whenever the value of this object is changed.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER connector-1(1), connector-2(2)  

ol51nnMTPCLModConn1Network 1.3.6.1.4.1.49.2.3.1.4.4.29.1.1.3
The network that this connector is attached to.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER ethernet-1(6), ethernet-2(7), ethernet-3(8), isolated-1(21), isolated-2(22)  

ol51nnMTPCLModConn2Network 1.3.6.1.4.1.49.2.3.1.4.4.29.1.1.4
The network that this connector is attached to.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER ethernet-1(6), ethernet-2(7), ethernet-3(8), isolated-1(21), isolated-2(22)  

ol51nnMTPCLModConn1DipNetwork 1.3.6.1.4.1.49.2.3.1.4.4.29.1.1.5
The network indicated by the connector dip switch.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ethernet-1(6), ethernet-2(7), ethernet-3(8), isolated-1(21), isolated-2(22)  

ol51nnMTPCLModConn2DipNetwork 1.3.6.1.4.1.49.2.3.1.4.4.29.1.1.6
The network indicated by the connector dip switch.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ethernet-1(6), ethernet-2(7), ethernet-3(8), isolated-1(21), isolated-2(22)  

ol51nnMTPCLModAutoPartition 1.3.6.1.4.1.49.2.3.1.4.4.29.1.1.7
This object holds the consecutive collision count limit value. The module goes into the auto-partition mode whenever the consecutive collision count exceeds the consecutive collision limit count.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER collisions-31(1), collisions-63(2), collisions-127(3), collisions-255(4)  

ol51nnMTPCLPortTable 1.3.6.1.4.1.49.2.3.1.4.4.29.2
A table of port-specific information for each port of this module type.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Ol51nnMTPCLPortEntry

ol51nnMTPCLPortEntry 1.3.6.1.4.1.49.2.3.1.4.4.29.2.1
A list of module-specific information about a specific 51nnM-TPCL port in the concentrator.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Ol51nnMTPCLPortEntry  

ol51nnMTPCLPortSlotIndex 1.3.6.1.4.1.49.2.3.1.4.4.29.2.1.1
The slot number of this port's module.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ol51nnMTPCLPortIndex 1.3.6.1.4.1.49.2.3.1.4.4.29.2.1.2
The port number of this port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ol51nnMTPCLPortAdminState 1.3.6.1.4.1.49.2.3.1.4.4.29.2.1.3
The desired state of this port. Setting this port to be redundant or for remote diagnostics with invalid settings of buddy slot and buddy port will return the genError error.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2), redundant-primary(3), redundant-backup(4), remote-diagnostics(8)  

ol51nnMTPCLPortBuddySlot 1.3.6.1.4.1.49.2.3.1.4.4.29.2.1.4
The slot index of the redundant port's buddy. To set a port to be redundant, the buddy's slot and port must be set to valid values. The buddy is automatically set to be redundant to this port. If the port is configured for remote diagnostics, then this contains the slot index of the backup buddy port. To configure a port for remote diagnostics, the buddy's slot and port must be set to valid values.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

ol51nnMTPCLPortBuddyPort 1.3.6.1.4.1.49.2.3.1.4.4.29.2.1.5
The port index of the redundant port's buddy. To set a port to be redundant, the buddy's slot and port must be set to valid values. The buddy is automatically set to be redundant to this port. If the port is configured for remote diagnostics, then this contains the port index of the backup buddy port. To configure a port for remote diagnostics, the buddy's slot and port must be set to valid values.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

ol51nnMTPCLPortDipAdminState 1.3.6.1.4.1.49.2.3.1.4.4.29.2.1.6
The state of this port as indicated by the port's dip switches.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

ol51nnMTPCLPortLinkInteg 1.3.6.1.4.1.49.2.3.1.4.4.29.2.1.7
The current link integrity configuration for this port.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

ol51nnMTPCLPortDipLinkInteg 1.3.6.1.4.1.49.2.3.1.4.4.29.2.1.8
The link integrity configuration as indicated by this dip switch.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

ol52nnBTTModTable 1.3.6.1.4.1.49.2.3.1.4.4.30.1
A table of module-specific information for each 52nnB-TT module in the concentrator.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Ol52nnBTTModEntry

ol52nnBTTModEntry 1.3.6.1.4.1.49.2.3.1.4.4.30.1.1
A list of module-specific information about a specific 52nnB-TT module in the concentrator.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Ol52nnBTTModEntry  

ol52nnBTTModSlotIndex 1.3.6.1.4.1.49.2.3.1.4.4.30.1.1.1
The slot number of this module.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ol52nnBTTModBridgeType 1.3.6.1.4.1.49.2.3.1.4.4.30.1.1.2
Whether the bridge is a source-routing bridge or a source-routing-transparent bridge.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER bridge-type-sr(1), bridge-type-srt(2)  

ol52nnBTTModSoftwareVersion 1.3.6.1.4.1.49.2.3.1.4.4.30.1.1.3
The version number of the software loaded into the module's flash chips.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(1..10)  

ol52nnBTTModSRBridgeNo 1.3.6.1.4.1.49.2.3.1.4.4.30.1.1.4
The module's source routing bridge number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ol52nnBTTModNetworkStatus 1.3.6.1.4.1.49.2.3.1.4.4.30.1.1.5
The status of the ring containing this module.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER okay(1), closed(2), beaconing(3)  

ol52nnBTTPortTable 1.3.6.1.4.1.49.2.3.1.4.4.30.2
A table of port-specific for each port of each 52nnB-TT module i the concentrator.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Ol52nnBTTPortEntry

ol52nnBTTPortEntry 1.3.6.1.4.1.49.2.3.1.4.4.30.2.1
A list of port-specific information about a specific 52nnB-TT port in the concentrator.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Ol52nnBTTPortEntry  

ol52nnBTTPortSlotIndex 1.3.6.1.4.1.49.2.3.1.4.4.30.2.1.1
The slot number for this port's module.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ol52nnBTTPortIndex 1.3.6.1.4.1.49.2.3.1.4.4.30.2.1.2
The port number for this port within this slot.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ol52nnBTTPortConnector 1.3.6.1.4.1.49.2.3.1.4.4.30.2.1.3
The port connector. Notice that setting port connector available only for the front pannel port.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER backPlane(1), rj45(8), db-9(10)  

ol52nnBTTPortSTAPState 1.3.6.1.4.1.49.2.3.1.4.4.30.2.1.4
The port connector. Notice that setting port connector available only for the front pannel port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER disabled(1), blocking(2), listening(3), learning(4), forwarding(5), off(6)  

ol52nnBTTPortIpAddress 1.3.6.1.4.1.49.2.3.1.4.4.30.2.1.5
The IP address associated with this port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  IpAddress  

ol52nnBTTPortMACAddress 1.3.6.1.4.1.49.2.3.1.4.4.30.2.1.6
A 6 octet address that uniquely identifies this port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(6)  

ol52nnBTTPortThroughput 1.3.6.1.4.1.49.2.3.1.4.4.30.2.1.7
Port throughput measured in Kbytes per second.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

ol52nnBTTPortForwarding 1.3.6.1.4.1.49.2.3.1.4.4.30.2.1.8
Port forwarding rate measured in frames per second.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

ol52nnBTTPortSRRingNo 1.3.6.1.4.1.49.2.3.1.4.4.30.2.1.9
The port's source routing ring number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ol52nnBTTPortRingSpeed 1.3.6.1.4.1.49.2.3.1.4.4.30.2.1.10
The ring's bandwidth.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER fourMegabit(1), sixteenMegabit(2)  

ol52nnBTTTrunkTable 1.3.6.1.4.1.49.2.3.1.4.4.30.3
A table that contains trunk-specific information for each trunk on each 52nnB-TT in the concentrator.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Ol52nnBTTTrunkEntry

ol52nnBTTTrunkEntry 1.3.6.1.4.1.49.2.3.1.4.4.30.3.1
A list of information about a specific Trunk on a 52nnB-TT module in the concentrator.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Ol52nnBTTTrunkEntry  

ol52nnBTTTrunkSlotIndex 1.3.6.1.4.1.49.2.3.1.4.4.30.3.1.1
The slot number of this module. Its value ranges between 1 and olConcNumSlots.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ol52nnBTTTrunkIndex 1.3.6.1.4.1.49.2.3.1.4.4.30.3.1.2
The trunk number of this module. Its value ranges between 1 and olModNumTrunks.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ol52nnMMGTModTable 1.3.6.1.4.1.49.2.3.1.4.4.32.1
A table that contains module information about each 52nnM-MGT in the concentrator.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Ol52nnMMGTModEntry

ol52nnMMGTModEntry 1.3.6.1.4.1.49.2.3.1.4.4.32.1.1
A list of module information for each 52nnM-MGT in the concentrator.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Ol52nnMMGTModEntry  

ol52nnMMGTModSlotIndex 1.3.6.1.4.1.49.2.3.1.4.4.32.1.1.1
The slot number of this module. Its value ranges between 1 and olConcNumSlots.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ol52nnMMGTModMasterPriority 1.3.6.1.4.1.49.2.3.1.4.4.32.1.1.2
The mastership priority of this agent. Ten is the highest and one is the lowest. Priority is only used when an election occurs. Mastership is not preemptive unless the reset mastership command is used.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER one(1), two(2), three(3), four(4), five(5), six(6), seven(7), eight(8), nine(9), ten(10)  

ol52nnMMGTModMasterStatus 1.3.6.1.4.1.49.2.3.1.4.4.32.1.1.3
The mastership status of this agent.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER master(1), non-master(2), electing(3)  

ol52nnMMGTModStationAddr 1.3.6.1.4.1.49.2.3.1.4.4.32.1.1.4
A 6 octet address that uniquely identifies this module. The station address is the MAC address of port 1.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

ol52nnMMGTModRingSpeed 1.3.6.1.4.1.49.2.3.1.4.4.32.1.1.5
The ring's bandwidth.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER fourMegabit(1), sixteenMegabit(2)  

ol52nnMMGTModNetworkStatus 1.3.6.1.4.1.49.2.3.1.4.4.32.1.1.6
The status of the ring containing this module.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER okay(1), closed(2), beaconing(3)  

ol52nnMMGTModMasterNetwork 1.3.6.1.4.1.49.2.3.1.4.4.32.1.1.7
The network that this module should assign itself to upon becoming master if the module was previously a slave. no-change(25) indicates that the module should not change its current network assignment.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER isolated(2), token-ring-1(9), token-ring-2(10), token-ring-3(11), token-ring-4(12), token-ring-5(13), token-ring-6(14), token-ring-7(15), no-change(25)  

ol52nnMMGTModLocalMACAddress 1.3.6.1.4.1.49.2.3.1.4.4.32.1.1.8
A MAC address with the locally administered bit set to one. Setting this value to an invalid address will return invalidData error. An invalid address is a value with the locally administered bit set to zero, or a value of all ones.
Status: mandatory Access: read-write
OBJECT-TYPE    
  MacAddress  

ol52nnMMGTModMACAddressType 1.3.6.1.4.1.49.2.3.1.4.4.32.1.1.9
The desired MAC address for this agent. burned-in(1) indicates that the factory setting as defined in ol52nnMMGTModStationAddr should be used. locally-administered(2) indicates that the MAC address set in ol52nnMMGTModLocalMACAddress should be used. This change will take effect following a reset of the agent. The actual MAC address in use is defined in ol52nnMMGTModActiveMACAddress. Setting this value to use an invalid MAC address (for example, all zeros) will return invalidData error.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER burned-in(1), locally-administered(2)  

ol52nnMMGTModActiveMACAddress 1.3.6.1.4.1.49.2.3.1.4.4.32.1.1.10
A actual MAC address that is being used by this agent. This is the MAC address of port 1.
Status: mandatory Access: read-only
OBJECT-TYPE    
  MacAddress  

ol52nnMMGTPortTable 1.3.6.1.4.1.49.2.3.1.4.4.32.2
A table that contains port-specific information for each port on each 52nnM-MGT in the concentrator.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Ol52nnMMGTPortEntry

ol52nnMMGTPortEntry 1.3.6.1.4.1.49.2.3.1.4.4.32.2.1
A list of information about a specific port on a 52nnM-MGT module in the concentrator.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Ol52nnMMGTPortEntry  

ol52nnMMGTPortSlotIndex 1.3.6.1.4.1.49.2.3.1.4.4.32.2.1.1
The slot number of this port's module.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ol52nnMMGTPortIndex 1.3.6.1.4.1.49.2.3.1.4.4.32.2.1.2
The port number of this port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ol52nnMMGTPortIpAddress 1.3.6.1.4.1.49.2.3.1.4.4.32.2.1.3
The IP address associated with this port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  IpAddress  

ol52nnMMGTTrunkTable 1.3.6.1.4.1.49.2.3.1.4.4.32.3
A table that contains trunk-specific information for each trunk on each 52nnM-MGT in the concentrator.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Ol52nnMMGTTrunkEntry

ol52nnMMGTTrunkEntry 1.3.6.1.4.1.49.2.3.1.4.4.32.3.1
A list of information about a specific Trunk on a 52nnM-MGT module in the concentrator.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Ol52nnMMGTTrunkEntry  

ol52nnMMGTTrunkSlotIndex 1.3.6.1.4.1.49.2.3.1.4.4.32.3.1.1
The slot number of this module. Its value ranges between 1 and olConcNumSlots.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ol52nnMMGTTrunkIndex 1.3.6.1.4.1.49.2.3.1.4.4.32.3.1.2
The slot number of this module. Its value ranges between 1 and olModNumTrunks.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ol52nnMMGTTrunkCableMon 1.3.6.1.4.1.49.2.3.1.4.4.32.3.1.3
The cable monitor configuration for this trunk.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enable(1), disable(2), notApplicable(3)  

ol52nnMMGTTrunkNetMapState 1.3.6.1.4.1.49.2.3.1.4.4.32.3.1.4
The map state of the copper ring-in trunk. This should be set to external for ring-in trunks which connect to external hubs. The mapping logic will not operate on trunks which are set to external. This prevents incorrect mapping which can occur when a module in one hub detects the mapping signal from another hub. This attribute only applies to copper ring-in trunks.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), internal(2), external(3)  

ol52nnMMGTTrunkExtBcnRecovery 1.3.6.1.4.1.49.2.3.1.4.4.32.3.1.5
Indicates whether the trunk is connected to a segment that will perform beacon recovery. This should be set to exists(1) for trunks which connect to hubs which perform beacon recovery. This attribute is used to determine the fault domain when resolving a beaconing condition. The beacon recovery process will resolve beaconing on trunks with this attribute set to nonExists(2) before trunks with the attribute set to exists(1) are resolved. For backplane trunks, setting to a value other than notApplicable will return invalidData error. The default value is nonExists(2).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER exists(1), nonExists(2), notApplicable(3)  

ol51nnIxModTable 1.3.6.1.4.1.49.2.3.1.4.4.31.1
A table of module-specific information for each 51nnI-x module in the concentrator.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Ol51nnIxModEntry

ol51nnIxModEntry 1.3.6.1.4.1.49.2.3.1.4.4.31.1.1
A list of module-specific information about a specific 51nnI-x module in the concentrator.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Ol51nnIxModEntry  

ol51nnIxModSlotIndex 1.3.6.1.4.1.49.2.3.1.4.4.31.1.1.1
The slot number of this module.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ol51nnIxModSwType 1.3.6.1.4.1.49.2.3.1.4.4.31.1.1.2
The software currently loaded and executing has the module operating as a Bridge, Switch or Router.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER bridge(1), switch(2), router(3)  

ol51nnIxModStationAddr 1.3.6.1.4.1.49.2.3.1.4.4.31.1.1.3
A 6 octet address that uniquely identifies this module. The station address is the mac address of port 1.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(6)  

ol51nnIxModDipPromDefaults 1.3.6.1.4.1.49.2.3.1.4.4.31.1.1.4
The current module configuration with respect to default PROM values as specified by dip switches.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER true(1), false(2)  

ol51nnIxModProtocols 1.3.6.1.4.1.49.2.3.1.4.4.31.1.1.5
A textual description of the protocols supported by this module
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

ol51nnIxPortTable 1.3.6.1.4.1.49.2.3.1.4.4.31.2
A table of port-specific information for each port of each 51nnI-x module in the concentrator.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Ol51nnIxPortEntry

ol51nnIxPortEntry 1.3.6.1.4.1.49.2.3.1.4.4.31.2.1
A list of port-specific information about a specific 51nnI-x port in the concentrator.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Ol51nnIxPortEntry  

ol51nnIxPortSlotIndex 1.3.6.1.4.1.49.2.3.1.4.4.31.2.1.1
The slot number for this port's module.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ol51nnIxPortIndex 1.3.6.1.4.1.49.2.3.1.4.4.31.2.1.2
The port number for this port within this slot.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ol51nnIxPortDipAdminState 1.3.6.1.4.1.49.2.3.1.4.4.31.2.1.3
The state of this port as indicated by the port's dip switches.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

ol51nnIxPortSTAPState 1.3.6.1.4.1.49.2.3.1.4.4.31.2.1.4
The current IEEE 802.1d Spanning Tree Algorithm and Protocol state (STAP) of this port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER disabled(1), blocking(2), listening(3), learning(4), forwarding(5), off(6), unknown(7)  

ol51nnIxPortIpAddress 1.3.6.1.4.1.49.2.3.1.4.4.31.2.1.5
The IP Address associated with this port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  IpAddress  

ol51nnIxPortDipNetwork 1.3.6.1.4.1.49.2.3.1.4.4.31.2.1.6
The network for this port as specified by this port's dip switches.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER isolated(2), front-panel(5), ethernet-1(6), ethernet-2(7), ethernet-3(8)  

ol51nnIxPortDefNetwork 1.3.6.1.4.1.49.2.3.1.4.4.31.2.1.7
The network for this port as specified by the OEIM's non-volatile storage.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER isolated(2), front-panel(5), ethernet-1(6), ethernet-2(7), ethernet-3(8)  

ol53nnMMGTModTable 1.3.6.1.4.1.49.2.3.1.4.4.25.1
A list of module attributes that apply to this model. To access an ol53nnMMGTModTable entry, the ol53nnMMGTModSlotIndex attribute is used.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Ol53nnMMGTModEntry

ol53nnMMGTModEntry 1.3.6.1.4.1.49.2.3.1.4.4.25.1.1
A list of module-specific information about a specific 53nnM-MGT module in the concentrator.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Ol53nnMMGTModEntry  

ol53nnMMGTModSlotIndex 1.3.6.1.4.1.49.2.3.1.4.4.25.1.1.1
A unique value that identifies a particular module. Its value ranges between 1 and olModSlotNumber. The module identified by a particular value of this index is the same module as indentified by the same value of olModSlotIndex.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ol53nnMMGTModMasterPriority 1.3.6.1.4.1.49.2.3.1.4.4.25.1.1.2
The mastership priority of this agent. Ten is the highest and one is the lowest. Priority is only used when an election occurs. Mastership is not preemptive unless the reset mastership command is used.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER one(1), two(2), three(3), four(4), five(5), six(6), seven(7), eight(8), nine(9), ten(10)  

ol53nnMMGTModMasterStatus 1.3.6.1.4.1.49.2.3.1.4.4.25.1.1.3
The mastership status of this agent.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER master(1), non-master(2), electing(3)  

ol53nnMMGTModStationAddr 1.3.6.1.4.1.49.2.3.1.4.4.25.1.1.4
A 6 octet address that uniquely identifies this module. The station address is the MAC address of port 1.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(6)  

ol53nnMMGTModIpAddress 1.3.6.1.4.1.49.2.3.1.4.4.25.1.1.5
The IP address associated with this module.
Status: mandatory Access: read-only
OBJECT-TYPE    
  IpAddress  

ol53nnMMGTModDownStreamMAC 1.3.6.1.4.1.49.2.3.1.4.4.25.1.1.6
Down stream MAC
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(6)  

ol53nnMMGTModUpStreamMAC 1.3.6.1.4.1.49.2.3.1.4.4.25.1.1.7
Up stream MAC
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(6)  

ol53nnMMGTModfddiMACPath 1.3.6.1.4.1.49.2.3.1.4.4.25.1.1.8
The FDDI path which should be inserted into the MAC
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER primary(1), secondary(2)  

ol53nnMMGTModDownStreamModule 1.3.6.1.4.1.49.2.3.1.4.4.25.1.1.9
Down stream slot (transmit to)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..16  

ol53nnMMGTModUpStreamModule 1.3.6.1.4.1.49.2.3.1.4.4.25.1.1.10
Up stream slot (receive from)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..16  

ol53nnMMGTModDownStreamOperPath 1.3.6.1.4.1.49.2.3.1.4.4.25.1.1.11
Transmit DBA (debug only)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER isolated(2), fddi-path-1(24), fddi-path-2(25), fddi-path-3(26), fddi-path-4(27), fddi-path-5(28), fddi-path-6(29), fddi-path-7(30), fddi-path-8(31)  

ol53nnMMGTModUpStreamOperPath 1.3.6.1.4.1.49.2.3.1.4.4.25.1.1.12
Receive DBA (debug only)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER isolated(2), fddi-path-1(24), fddi-path-2(25), fddi-path-3(26), fddi-path-4(27), fddi-path-5(28), fddi-path-6(29), fddi-path-7(30), fddi-path-8(31)  

ol53nnMMGTModRingInfo 1.3.6.1.4.1.49.2.3.1.4.4.25.1.1.13
An array which is indexed by DBA number. Each element contains the slot number (1..16) which is assigned to transmit on this DBA. (debug only)
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(1..8)  

ol53nnMMGTPortTable 1.3.6.1.4.1.49.2.3.1.4.4.25.2
A table of port-specific information for each port of this module type.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Ol53nnMMGTPortEntry

ol53nnMMGTPortEntry 1.3.6.1.4.1.49.2.3.1.4.4.25.2.1
A list of module-specific information about a specific 53nnM-MGT port in the concentrator.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Ol53nnMMGTPortEntry  

ol53nnMMGTPortSlotIndex 1.3.6.1.4.1.49.2.3.1.4.4.25.2.1.1
A unique value that identifies a particular module. Its value ranges between 1 and olModSlotNumber. The module identified by a particular value of this index is the same module as indentified by the same value of olPortSlotIndex.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ol53nnMMGTPortIndex 1.3.6.1.4.1.49.2.3.1.4.4.25.2.1.2
A unique value that identifies a particular port within this module. Its value ranges between 1 and olModPortNumber. The module identified by a particular value of this index is the same module as indentified by the same value of olPortIndex.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ol53nnMMGTPortConfig 1.3.6.1.4.1.49.2.3.1.4.4.25.2.1.3
Specifies the FDDI port type (a or b).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER a(1), b(2)  

ol53nnMMGTPortPcmState 1.3.6.1.4.1.49.2.3.1.4.4.25.2.1.4
(refer to ANSI SMT 9.6.2).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER pc0(1), pc1(2), pc2(3), pc3(4), pc4(5), pc5(6), pc6(7), pc7(8), pc8(9), pc9(10)  

ol53nnMMGTPortConnectState 1.3.6.1.4.1.49.2.3.1.4.4.25.2.1.5
An indication of the connect state of this PORT. Basically, this gives a higher level view of the state of the connection by grouping PCM states and the PC-Withhold flag state. The supported values and their corresponding PCM states and PC-Withhold condition, when relevant, are: disabled: (PC0:Off, PC9:Maint) connecting: (PC1(Break) || PC3 (Connect) || PC4(next) || PC5 (Signal) || PC6(Join) || PC7 (Verify)) && (PC-Withhold = None) standby: (PC-Withhold != None) active: (PC2:Trace || PC8:Active)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER disabled(1), connecting(2), standby(3), active(4)  

ol53nnMMGTPortNeighbor 1.3.6.1.4.1.49.2.3.1.4.4.25.2.1.6
The type (PC-Neighbor) of the remote PORT that is determined in PC-Signaling in R-Val (1,2) (refer to ANSI SMT 9.6.3.2).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER a(1), b(2), slave(3), master(4), unknown(5)  

ol53nnMMGTPortRemoteMACIndicated 1.3.6.1.4.1.49.2.3.1.4.4.25.2.1.7
The indication, in PC-Signaling that the remote partner intends to place a MAC in the output token PATH of this PORT. Signaled as R-Val (9) (refer to ANSI SMT 9.6.3.2).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER true(1), false(2)  

ol53nnMMGTPortBSFlag 1.3.6.1.4.1.49.2.3.1.4.4.25.2.1.8
The Break State, BS-Flag (refer to ANSI SMT 9.4.3.4).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER true(1), false(2)  

ol53nnMMGTPortPCWithhold 1.3.6.1.4.1.49.2.3.1.4.4.25.2.1.9
PC-Withhold, (refer to ANSI SMT 9.4.1).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER none(1), m-m(2), other(3)  

ol53nnMMGTPortLerCondition 1.3.6.1.4.1.49.2.3.1.4.4.25.2.1.10
This variable is set to true whenever LerEstimate is less than or equal to LerAlarm (the larger the number the smaller the value).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER bad(1), okay(2)  

ol53nnMMGTTrunkTable 1.3.6.1.4.1.49.2.3.1.4.4.25.3
FDDI module specific trunk table variables. At present there are none.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Ol53nnMMGTTrunkEntry

ol53nnMMGTTrunkEntry 1.3.6.1.4.1.49.2.3.1.4.4.25.3.1
A description of 53nnM-MGT trunk attributes.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Ol53nnMMGTTrunkEntry  

ol53nnMMGTTrunkSlotIndex 1.3.6.1.4.1.49.2.3.1.4.4.25.3.1.1
A unique value that identifies a particular module. Its value ranges between 1 and olModSlotNumber. The module identified by a particular value of this index is the same module as indentified by the same value of olTrunkSlotIndex.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ol53nnMMGTTrunkIndex 1.3.6.1.4.1.49.2.3.1.4.4.25.3.1.2
A unique value that identifies a particular trunk within this module. Its value ranges between 1 and olModTrunkNumber. The module identified by a particular value of this index is the same module as indentified by the same value of olTrunkIndex.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ol50nnMHCTLModTable 1.3.6.1.4.1.49.2.3.1.4.4.33.1
A table that contains information about each 50nnM-HCTL in the concentrator.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Ol50nnMHCTLModEntry

ol50nnMHCTLModEntry 1.3.6.1.4.1.49.2.3.1.4.4.33.1.1
A list of information for each 50nnM-HCTL module in the concentrator.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Ol50nnMHCTLModEntry  

ol50nnMHCTLModSlotIndex 1.3.6.1.4.1.49.2.3.1.4.4.33.1.1.1
The slot number for this module. The value should be 7.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ol50nnMHCTLModOperState 1.3.6.1.4.1.49.2.3.1.4.4.33.1.1.2
The operational state of the 50nnM-HCTL module. Specifically, this is an indicator of whether the 50nnM-HCTL module is providing clock signals to the backplane. An active 50nnM-HCTL module provides clock signals to the backplane while a standby 50nnM-HCTL module does not. Note that only one 50nnM-HCTL module will be active at any given time; all other 50nnM-HCTL/ 50nnM-RCTL modules in the concentrator will be in standby mode.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER active(1), standby(2)  

ol50nnMHCTLModClockStatus 1.3.6.1.4.1.49.2.3.1.4.4.33.1.1.3
The current status of the on-board clocks on this module.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER okay(1), faulty(2)  

ol50nnMHCTLModTempStatus 1.3.6.1.4.1.49.2.3.1.4.4.33.1.1.4
The temperature as detected by the probe on this module.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER okay(1), extremeTemp(2)  

ol50nnMHCTLModPDBStatus 1.3.6.1.4.1.49.2.3.1.4.4.33.1.1.5
Indicates whether this 6-slot concentrator contains a power distribution board that supports powersupply redundancy.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER present(1), notPresent(2)  

ol50nnMHCTLModDipCh1ActCol 1.3.6.1.4.1.49.2.3.1.4.4.33.1.1.6
The Ethernet channel 1 activity/collision LED configuration as indicated by this module's dip switches.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

ol50nnMHCTLModDipCh2ActCol 1.3.6.1.4.1.49.2.3.1.4.4.33.1.1.7
The Ethernet channel 2 activity/collision LED configuration as indicated by this module's dip switches.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

ol50nnMHCTLModDipCh3ActCol 1.3.6.1.4.1.49.2.3.1.4.4.33.1.1.8
The Ethernet channel 3 activity/collision LED configuration as indicated by this module's dip switches.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

ol50nnMRCLSModTable 1.3.6.1.4.1.49.2.3.1.4.4.51.1
A table that contains information about each Redundant Controller in the concentrator.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Ol50nnMRCLSModEntry

ol50nnMRCLSModEntry 1.3.6.1.4.1.49.2.3.1.4.4.51.1.1
A list of information for each Load Sharing Redundant controller module in the concentrator.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Ol50nnMRCLSModEntry  

ol50nnMRCLSModSlotIndex 1.3.6.1.4.1.49.2.3.1.4.4.51.1.1.1
The slot number for this module.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ol50nnMRCLSModOperState 1.3.6.1.4.1.49.2.3.1.4.4.51.1.1.2
The operational state of the Load Sharing Redudant Controller module. Specifically, this is an indicator of whether the Load Sharing Redudant Controller module is providing clock signals to the backplane. An active Load Sharing Redudant Controller module provides clock signals to the backplane while a standby Load Sharing Redudant Controller module does not. Note that only one Load Sharing Redudant Controller module will be active at any given time; all other Load Sharing Redudant Controller modules in the concentrator will be in standby mode.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER active(1), standby(2)  

ol50nnMRCLSModClockStatus 1.3.6.1.4.1.49.2.3.1.4.4.51.1.1.3
The current status of the on-board clocks on this module.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER okay(1), faulty(2)  

ol50nnMRCLSModTempStatus 1.3.6.1.4.1.49.2.3.1.4.4.51.1.1.4
The temperature as detected by the probe on this module.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER okay(1), extremeTemp(2)  

ol51nnMTPLSModTable 1.3.6.1.4.1.49.2.3.1.4.4.48.1
A list of module-specific information about a specific 51nnM-TPLS module in the concentrator.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Ol51nnMTPLSModEntry

ol51nnMTPLSModEntry 1.3.6.1.4.1.49.2.3.1.4.4.48.1.1
A list of module-specific information about a specific 51nnM-TPLS module in the concentrator.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Ol51nnMTPLSModEntry  

ol51nnMTPLSModSlotIndex 1.3.6.1.4.1.49.2.3.1.4.4.48.1.1.1
The slot number of this module.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ol51nnMTPLSModDipNetwork 1.3.6.1.4.1.49.2.3.1.4.4.48.1.1.2
The network indicated by the module's dip switches.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER isolated(2), ethernet-1(6), ethernet-2(7), ethernet-3(8)  

ol51nnMTPLSModAutoPartition 1.3.6.1.4.1.49.2.3.1.4.4.48.1.1.3
This object holds the consecutive collision count limit value. The module goes into the auto-partition mode whenever the consecutive collision count exceeds this limit.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER collisions-31(1), collisions-63(2), collisions-127(3), collisions-255(4)  

ol51nnMTPLSPortTable 1.3.6.1.4.1.49.2.3.1.4.4.48.2
A table of port-specific information for each port of this module type.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Ol51nnMTPLSPortEntry

ol51nnMTPLSPortEntry 1.3.6.1.4.1.49.2.3.1.4.4.48.2.1
A list of module-specific information about a specific 51nnM-TPLS port in the concentrator.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Ol51nnMTPLSPortEntry  

ol51nnMTPLSPortSlotIndex 1.3.6.1.4.1.49.2.3.1.4.4.48.2.1.1
The slot number of this port's module.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ol51nnMTPLSPortIndex 1.3.6.1.4.1.49.2.3.1.4.4.48.2.1.2
The port number of this port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ol51nnMTPLSPortAdminState 1.3.6.1.4.1.49.2.3.1.4.4.48.2.1.3
The desired state of this port. Setting this port to be redundant or for remote diagnostics with invalid settings of buddy slot and buddy port will return the genError error.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2), redundant-primary(3), redundant-backup(4), remote-diagnostics(8)  

ol51nnMTPLSPortDipAdminState 1.3.6.1.4.1.49.2.3.1.4.4.48.2.1.4
The admin state of this port as indicated by the dip switches. i.e. This object indicates whether the port will initialize to enabled or disabled when the module configures itself from dips.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

ol51nnMTPLSPortDipSecurity 1.3.6.1.4.1.49.2.3.1.4.4.48.2.1.5
The security state of this port as indicated by the dip switches. i.e. This object indicates whether the port's security state will initialize to enabled (full security) or disabled (no security) when the module configures itself from dips.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

ol51nnMTPLSPortBuddySlot 1.3.6.1.4.1.49.2.3.1.4.4.48.2.1.6
The slot index of the redundant port's buddy. To set a port to be redundant, the buddy's slot and port must be set to valid values. The buddy is automatically set to be redundant to this port. If the port is configured for remote diagnostics, then this contains the slot index of the backup buddy port. To configure a port for remote diagnostics, the buddy's slot and port must be set to valid values.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

ol51nnMTPLSPortBuddyPort 1.3.6.1.4.1.49.2.3.1.4.4.48.2.1.7
The port index of the redundant port's buddy. To set a port to be redundant, the buddy's slot and port must be set to valid values. The buddy is automatically set to be redundant to this port. If the port is configured for remote diagnostics, then this contains the port index of the backup buddy port. To configure a port for remote diagnostics, the buddy's slot and port must be set to valid values.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

ol51nnMTPLSPortLinkInteg 1.3.6.1.4.1.49.2.3.1.4.4.48.2.1.8
The current link integrity configuration for this port.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

ol51nnMTPLSPortDipLinkInteg 1.3.6.1.4.1.49.2.3.1.4.4.48.2.1.9
The link integrity configuration as indicated by this module's dip switches.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

oc61nnMTPLPortTable 1.3.6.1.4.1.49.2.3.1.4.4.47.2
A table of port-specific information for each port of this module type.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Oc61nnMTPLPortEntry

oc61nnMTPLPortEntry 1.3.6.1.4.1.49.2.3.1.4.4.47.2.1
A list of module-specific information about a specific 61nnM-TPL port in the concentrator.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Oc61nnMTPLPortEntry  

oc61nnMTPLPortSlotIndex 1.3.6.1.4.1.49.2.3.1.4.4.47.2.1.1
The slot number of this port's module.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

oc61nnMTPLPortIndex 1.3.6.1.4.1.49.2.3.1.4.4.47.2.1.2
The port number of this port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

oc61nnMTPLPortAdminState 1.3.6.1.4.1.49.2.3.1.4.4.47.2.1.3
The desired state of this port. Setting this port to be redundant or for remote diagnostics with invalid settings of buddy slot and buddy port will return the genError error.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2), redundant-primary(3), redundant-backup(4), remote-diagnostics(8)  

oc61nnMTPLPortBuddySlot 1.3.6.1.4.1.49.2.3.1.4.4.47.2.1.4
The slot index of the redundant port's buddy. To set a port to be redundant, the buddy's slot and port must be set to valid values. The buddy is automatically set to be redundant to this port. If the port is configured for remote diagnostics, then this contains the slot index of the backup buddy port. To configure a port for remote diagnostics, the buddy's slot and port must be set to valid values.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

oc61nnMTPLPortBuddyPort 1.3.6.1.4.1.49.2.3.1.4.4.47.2.1.5
The port index of the redundant port's buddy. To set a port to be redundant, the buddy's slot and port must be set to valid values. The buddy is automatically set to be redundant to this port. If the port is configured for remote diagnostics, then this contains the port index of the backup buddy port. To configure a port for remote diagnostics, the buddy's slot and port must be set to valid values.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

oc61nnMTPLPortDipNetwork 1.3.6.1.4.1.49.2.3.1.4.4.47.2.1.6
The network indicated by the port's dip switches.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ethernet-1(6), ethernet-2(7), ethernet-3(8), isolated-1(21), ethernet-4(32), ethernet-5(33), ethernet-6(34), ethernet-7(35), ethernet-8(36)  

oc61nnMTPLPortLinkInteg 1.3.6.1.4.1.49.2.3.1.4.4.47.2.1.7
The current link integrity configuration for this port. Setting this object to enabled(1) makes it conform to the 10BASE-T link integrity standard. Setting this object to disabled(2) makes it compatible with the older pre 10BASE-T module.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

oc61nnMTPLPortAutoPolarity 1.3.6.1.4.1.49.2.3.1.4.4.47.2.1.8
The current auto polarity configuration for this port. Setting this object to enabled(1) causes the module to switch the port polarity automatically when the port polarity is reverted.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

oc61nnMTPLModTable 1.3.6.1.4.1.49.2.3.1.4.4.47.6
A list of module-specific information about a specific 61nnM-TPL module in the concentrator.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Oc61nnMTPLModEntry

oc61nnMTPLModEntry 1.3.6.1.4.1.49.2.3.1.4.4.47.6.1
A list of module-specific information about a specific 61nnM-TPL module in the concentrator.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Oc61nnMTPLModEntry  

oc61nnMTPLModSlotIndex 1.3.6.1.4.1.49.2.3.1.4.4.47.6.1.1
The slot number of this module.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

oc61nnMTPLModSubSlotIndex 1.3.6.1.4.1.49.2.3.1.4.4.47.6.1.2
The subslot number of this module.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

oc61nnMTPLModBootVersion 1.3.6.1.4.1.49.2.3.1.4.4.47.6.1.3
The software boot eprom version of this module.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(1..32)  

oc61nnMTPLModDipNVRam 1.3.6.1.4.1.49.2.3.1.4.4.47.6.1.4
The Non-Volatile RAM dip switch setting for this module. Enabling this switch will cause the module to be configured according to the configurations that were saved in the non-volatile storage after the module reset.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

oc61nnMCARModTable 1.3.6.1.4.1.49.2.3.1.4.4.35.6
A list of module-specific information associated with a particular 61nnM-CAR module in the concentrator.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Oc61nnMCARModEntry

oc61nnMCARModEntry 1.3.6.1.4.1.49.2.3.1.4.4.35.6.1
A list of module-specific information about a specific 61nnM-CAR module in the concentrator.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Oc61nnMCARModEntry  

oc61nnMCARModSlotIndex 1.3.6.1.4.1.49.2.3.1.4.4.35.6.1.1
The slot number of this module.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

oc61nnMCARModSubSlotIndex 1.3.6.1.4.1.49.2.3.1.4.4.35.6.1.2
The subslot number of this module.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

oc61nnMCARModBootVersion 1.3.6.1.4.1.49.2.3.1.4.4.35.6.1.3
The software boot eprom version of this module.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(1..32)  

oc61nnMFBPPortTable 1.3.6.1.4.1.49.2.3.1.4.4.46.2
A table of port-specific information for each port of this module type.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Oc61nnMFBPPortEntry

oc61nnMFBPPortEntry 1.3.6.1.4.1.49.2.3.1.4.4.46.2.1
A list of port specific information about this module's ports.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Oc61nnMFBPPortEntry  

oc61nnMFBPPortSlotIndex 1.3.6.1.4.1.49.2.3.1.4.4.46.2.1.1
The slot number of the module assocaited with this port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

oc61nnMFBPPortIndex 1.3.6.1.4.1.49.2.3.1.4.4.46.2.1.2
The port number with respect to the module it resides on.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

oc61nnMFBPPortAdminState 1.3.6.1.4.1.49.2.3.1.4.4.46.2.1.3
The desired state of this port. Setting this port to redundant-primary or redundant-backup with invalid buddy slot or buddy port will result in an error.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2), redundant-primary(3), redundant-backup(4)  

oc61nnMFBPPortBuddySlot 1.3.6.1.4.1.49.2.3.1.4.4.46.2.1.4
The slot index of the redundant port's buddy port.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

oc61nnMFBPPortBuddyPort 1.3.6.1.4.1.49.2.3.1.4.4.46.2.1.5
The port index of the redundant port's buddy. Valid ports are those ports which are not redundant. The buddy port admin state will be set to redundant.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

oc61nnMFBPPortDipNetwork 1.3.6.1.4.1.49.2.3.1.4.4.46.2.1.6
The network indicated by the port's dip switches.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ethernet-1(6), ethernet-2(7), ethernet-3(8), isolated-1(21), ethernet-4(32), ethernet-5(33), ethernet-6(34), ethernet-7(35), ethernet-8(36)  

oc61nnMFBPPortHipwr 1.3.6.1.4.1.49.2.3.1.4.4.46.2.1.7
The current port high power optics mode. Setting this variable to enable(1), will enable the port to drive up to 4K meter fiber cable.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

oc61nnMFBPModTable 1.3.6.1.4.1.49.2.3.1.4.4.46.6
A list of module specific information about this module.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Oc61nnMFBPModEntry

oc61nnMFBPModEntry 1.3.6.1.4.1.49.2.3.1.4.4.46.6.1
Values to describe module specific inormation.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Oc61nnMFBPModEntry  

oc61nnMFBPModSlotIndex 1.3.6.1.4.1.49.2.3.1.4.4.46.6.1.1
The slot index of this module.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

oc61nnMFBPModSubSlotIndex 1.3.6.1.4.1.49.2.3.1.4.4.46.6.1.2
The subslot index of this module. (e.g. mother boards have subslot index equals to one.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

oc61nnMFBPModBootVersion 1.3.6.1.4.1.49.2.3.1.4.4.46.6.1.3
The software boot eprom version of this module.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(1..32)  

oc61nnMFBPModDipNVRam 1.3.6.1.4.1.49.2.3.1.4.4.46.6.1.4
The Non-Volatile RAM dip switch setting for this module. Setting this object to enable(1) will cause the module to be configured according to the configuration which was saved in the non-volatile storage.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

ol60nnMRCTLModTable 1.3.6.1.4.1.49.2.3.1.4.4.50.1
A table that contains information about the Controller in the concentrator.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Ol60nnMRCTLModEntry

ol60nnMRCTLModEntry 1.3.6.1.4.1.49.2.3.1.4.4.50.1.1
A list of information for the Controller module in the concentrator.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Ol60nnMRCTLModEntry  

ol60nnMRCTLModSlotIndex 1.3.6.1.4.1.49.2.3.1.4.4.50.1.1.1
The slot number for this module. Note that this module will always be in slot 17.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ol60nnMRCTLModOperState 1.3.6.1.4.1.49.2.3.1.4.4.50.1.1.2
The operational state of the Controller module. Specifically, this is an indicator of whether the Controller module is providing clock signals to the backplane. An active Controller module provides clock signals to the backplane while a standby Controller module does not. Note that only the active Controller is visible to an ONline agent; hence, this object will have the value active(1).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER active(1), standby(2)  

ol60nnMRCTLModClockStatus 1.3.6.1.4.1.49.2.3.1.4.4.50.1.1.3
The current status of the on-board clocks on this module.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER okay(1), faulty(2)  

ol60nnMRCTLModTempStatus 1.3.6.1.4.1.49.2.3.1.4.4.50.1.1.4
The overall temperature status for this concentrator as detected by this module. This object's value is an aggregate of all temperature probes located within this concentrator as sensed by this module. Hence, when at least one probe in the concentrator reports an extreme temperature, then this object will have the value extremeTemp(2).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER okay(1), extremeTemp(2)  

oc60nnMRCTLModTable 1.3.6.1.4.1.49.2.3.1.4.4.50.6
A table that contains information about the Controller in the concentrator.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Oc60nnMRCTLModEntry

oc60nnMRCTLModEntry 1.3.6.1.4.1.49.2.3.1.4.4.50.6.1
A list of information for the Controller module in the concentrator.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Oc60nnMRCTLModEntry  

oc60nnMRCTLModSlotIndex 1.3.6.1.4.1.49.2.3.1.4.4.50.6.1.1
The slot number for this module.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

oc60nnMRCTLModSubSlotIndex 1.3.6.1.4.1.49.2.3.1.4.4.50.6.1.2
The subslot number for this module.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

oc60nnMRCTLModBootVersion 1.3.6.1.4.1.49.2.3.1.4.4.50.6.1.3
The software boot eprom version of this module.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(1..32)  

oc60nnMRCTLModOperState 1.3.6.1.4.1.49.2.3.1.4.4.50.6.1.4
The operational state of the Controller module. Specifically, this is an indicator of whether the Controller module is providing clock signals to the backplane. An active Controller module provides clock signals to the backplane while a standby Controller module does not.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER active(1), standby(2)  

oc60nnMRCTLModClockStatus 1.3.6.1.4.1.49.2.3.1.4.4.50.6.1.5
The current status of the on-board clocks on this module.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER okay(1), faulty(2)  

oc60nnMRCTLModTempStatus 1.3.6.1.4.1.49.2.3.1.4.4.50.6.1.6
The overall temperature status for the concentrator as detected by this module. This object's value is an aggregate of all the temperature probes located within this concentrator as sensed by this module. Hence, when at least one probe in the concentrator reports an extreme temperature, then this object will have the value extremeTemp(2).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER okay(1), extremeTemp(2)  

oc60nnMRCTLModAtoDConverterStatus 1.3.6.1.4.1.49.2.3.1.4.4.50.6.1.7
The current status of the on-board A/D converter. Typically, when this object has a value of faulty(2), it is because the value obtained from the A/D converter internal test channel is out of tolerance from what is specified by the manufacturer.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER okay(1), faulty(2)  

oc60nnMRCTLModPS1Status 1.3.6.1.4.1.49.2.3.1.4.4.50.6.1.8
The current status of powersupply 1.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER active(1), faulty(3), not-installed(4)  

oc60nnMRCTLModPS2Status 1.3.6.1.4.1.49.2.3.1.4.4.50.6.1.9
The current status of powersupply 2.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER active(1), faulty(3), not-installed(4)  

oc60nnMRCTLModPS3Status 1.3.6.1.4.1.49.2.3.1.4.4.50.6.1.10
The current status of powersupply 3.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER active(1), faulty(3), not-installed(4)  

oc60nnMRCTLModPS4Status 1.3.6.1.4.1.49.2.3.1.4.4.50.6.1.11
The current status of powersupply 4.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER active(1), faulty(3), not-installed(4)  

oc61nnDMGTModTable 1.3.6.1.4.1.49.2.3.1.4.4.45.6
A table that contains information about Ethernet Network Monitor Cards in the ONcore Hub.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Oc61nnDMGTModEntry

oc61nnDMGTModEntry 1.3.6.1.4.1.49.2.3.1.4.4.45.6.1
A list of information for an Ethernet Network Monitor Card in the ONcore Hub.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Oc61nnDMGTModEntry  

oc61nnDMGTModSlotIndex 1.3.6.1.4.1.49.2.3.1.4.4.45.6.1.1
The slot number of this card.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

oc61nnDMGTModSubSlotIndex 1.3.6.1.4.1.49.2.3.1.4.4.45.6.1.2
The subslot number of this card.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

oc61nnDMGTModBootVersion 1.3.6.1.4.1.49.2.3.1.4.4.45.6.1.3
The software boot eprom version of this module.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(1..32)  

oc61nnDMGTModIpAddress 1.3.6.1.4.1.49.2.3.1.4.4.45.6.1.4
The current IP address of this card and the associated interface.
Status: mandatory Access: read-only
OBJECT-TYPE    
  IpAddress  

oc61nnDMGTModSubnetMask 1.3.6.1.4.1.49.2.3.1.4.4.45.6.1.5
The current subnet mask of this card and the associated interface.
Status: mandatory Access: read-only
OBJECT-TYPE    
  IpAddress  

oc61nnDMGTModDefaultGateway 1.3.6.1.4.1.49.2.3.1.4.4.45.6.1.6
The current default gateway of this card and the associated interface. Note that a value of 0.0.0.0 indicates that this interface is not con- configured to be used with a default gateway.
Status: mandatory Access: read-only
OBJECT-TYPE    
  IpAddress  

oc61nnDMGTModStationAddr 1.3.6.1.4.1.49.2.3.1.4.4.45.6.1.7
A 6 octet address that uniquely identifies this card. Note that an address of 00-00-00-00-00-00 is invalid and the module has failed.
Status: mandatory Access: read-only
OBJECT-TYPE    
  MacAddress  

oc61nnDMGTModInterfaceMode 1.3.6.1.4.1.49.2.3.1.4.4.45.6.1.8
The desired connectvity mode of this card. When this attribute is set to enabled(1) and the card is set to a network, it will forward messages to and from the master Distributed Management Module. If this attribute is set to disabled(2), the card may still collect statistics but not forward messages to and from the Distributed Management Module. If this attribute is set to standby(3), the card will not collect statistics or forward messages to/from the Distributed Management Module.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2), standby(3)  

oc61nnDMGTModRMONHostStatsMode 1.3.6.1.4.1.49.2.3.1.4.4.45.6.1.9
The desired RMON host staticstics mode of this card. When this attribute is set to enabled, the card will gather RMON host table statistics. Note that when this attribute is enabled, the accuracy of all statistics may be impaired during peak loads.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

oc60nnMMGTModTable 1.3.6.1.4.1.49.2.3.1.4.4.43.6
A table that contains module information about each 60nnM-MGT module in the concentrator.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Oc60nnMMGTModEntry

oc60nnMMGTModEntry 1.3.6.1.4.1.49.2.3.1.4.4.43.6.1
A list of module information for each 60nnM-MGT module in the concentrator.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Oc60nnMMGTModEntry  

oc60nnMMGTModSlotIndex 1.3.6.1.4.1.49.2.3.1.4.4.43.6.1.1
The slot number of this module.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

oc60nnMMGTModSubSlotIndex 1.3.6.1.4.1.49.2.3.1.4.4.43.6.1.2
The subslot number of this module.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

oc60nnMMGTModBootVersion 1.3.6.1.4.1.49.2.3.1.4.4.43.6.1.3
The software boot eprom version of this module.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(1..32)  

oc60nnMMGTModMasterPriority 1.3.6.1.4.1.49.2.3.1.4.4.43.6.1.4
The mastership priority of this agent. Ten is the highest and one is the lowest. Priority is only used when an election occurs. Mastership is not preemptive unless the reset mastership command is used.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER one(1), two(2), three(3), four(4), five(5), six(6), seven(7), eight(8), nine(9), ten(10)  

oc60nnMMGTModMasterStatus 1.3.6.1.4.1.49.2.3.1.4.4.43.6.1.5
The mastership status of this agent.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER master(1), non-master(2), electing(3)  

oc60nnMMGTModHubSerial 1.3.6.1.4.1.49.2.3.1.4.4.43.6.1.6
The Hub serial number mastership is presiding over. Zero length string for slaves.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

ol52nnMECModTable 1.3.6.1.4.1.49.2.3.1.4.4.62.1
A list of module-specific information associated with a particular 52nnM-EC module in the concentrator.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Ol52nnMECModEntry

ol52nnMECModEntry 1.3.6.1.4.1.49.2.3.1.4.4.62.1.1
A description of the 52nnM-EC module attributes.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Ol52nnMECModEntry  

ol52nnMECModSlotIndex 1.3.6.1.4.1.49.2.3.1.4.4.62.1.1.1
The slot number of this module.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ol52nnMECModSoftwareVersion 1.3.6.1.4.1.49.2.3.1.4.4.62.1.1.2
The version number of the software.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(1..10)  

ol52nnMECModSystemStatusCode 1.3.6.1.4.1.49.2.3.1.4.4.62.1.1.3
A 43 octet indication of the current applicable IBM 3174 System Status Code. For more information consult the 52nnM-EC reference manual.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(43)  

ol52nnMECModRingSpeed 1.3.6.1.4.1.49.2.3.1.4.4.62.1.1.4
The ring's bandwidth in Mega-bits per second.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER fourMegabit(1), sixteenMegabit(2)  

ol52nnMECModNetworkStatus 1.3.6.1.4.1.49.2.3.1.4.4.62.1.1.5
The status of the ring containing this module.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER okay(1), closed(2), beaconing(3)  

ol52nnMECModIpAddress 1.3.6.1.4.1.49.2.3.1.4.4.62.1.1.6
The IP Address of this module.
Status: mandatory Access: read-only
OBJECT-TYPE    
  IpAddress  

ol52nnMECModMACStationAddr 1.3.6.1.4.1.49.2.3.1.4.4.62.1.1.7
A 6 octet address that uniquely identifies the MAC address of this module.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

ol52nnMECPortTable 1.3.6.1.4.1.49.2.3.1.4.4.62.2
A table of port-specific information for each port of this module type.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Ol52nnMECPortEntry

ol52nnMECPortEntry 1.3.6.1.4.1.49.2.3.1.4.4.62.2.1
A description of this module's port attributes.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Ol52nnMECPortEntry  

ol52nnMECPortSlotIndex 1.3.6.1.4.1.49.2.3.1.4.4.62.2.1.1
The slot number of this port's module.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ol52nnMECPortIndex 1.3.6.1.4.1.49.2.3.1.4.4.62.2.1.2
The port number of this port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ol52nnMECTrunkTable 1.3.6.1.4.1.49.2.3.1.4.4.62.3
A list of trunk-specific information about each trunk for this module type.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Ol52nnMECTrunkEntry

ol52nnMECTrunkEntry 1.3.6.1.4.1.49.2.3.1.4.4.62.3.1
A description of 52nnM-EC trunk attributes.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Ol52nnMECTrunkEntry  

ol52nnMECTrunkSlotIndex 1.3.6.1.4.1.49.2.3.1.4.4.62.3.1.1
A unique value that identifies a particular module. Its value ranges between 1 and olModSlotNumber. The module identified by a particular value of this index is the same module as indentified by the same value of olTrunkSlotIndex.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ol52nnMECTrunkIndex 1.3.6.1.4.1.49.2.3.1.4.4.62.3.1.2
The trunk number for this trunk.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ol41nnHMTPModTable 1.3.6.1.4.1.49.2.3.1.4.4.52.1
A list of module-specific information associated with a particular ol41nnHMTP or ol41nnHMTP-FL module.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Ol41nnHMTPModEntry

ol41nnHMTPModEntry 1.3.6.1.4.1.49.2.3.1.4.4.52.1.1
A module entry containing objects that describe the module level for that particular module.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Ol41nnHMTPModEntry  

ol41nnHMTPModSlotIndex 1.3.6.1.4.1.49.2.3.1.4.4.52.1.1.1
The slot number of this module.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ol41nnHMTPModSerialNo 1.3.6.1.4.1.49.2.3.1.4.4.52.1.1.2
The serial number of this module, as entered by the user through the Management interface.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

ol41nnHMTPModProtocols 1.3.6.1.4.1.49.2.3.1.4.4.52.1.1.3
A list of the various protocols supported by the module's agent.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

ol41nnHMTPModIpAddress 1.3.6.1.4.1.49.2.3.1.4.4.52.1.1.4
The IP Address of this module.
Status: mandatory Access: read-only
OBJECT-TYPE    
  IpAddress  

ol41nnHMTPPortTable 1.3.6.1.4.1.49.2.3.1.4.4.52.2
A table of port-specific information for each port of this module type.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Ol41nnHMTPPortEntry

ol41nnHMTPPortEntry 1.3.6.1.4.1.49.2.3.1.4.4.52.2.1
A port entry containing objects that describe this port.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Ol41nnHMTPPortEntry  

ol41nnHMTPPortSlotIndex 1.3.6.1.4.1.49.2.3.1.4.4.52.2.1.1
The slot (stack) number of this port's module.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ol41nnHMTPPortIndex 1.3.6.1.4.1.49.2.3.1.4.4.52.2.1.2
The port number of this port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ol41nnHMTPPortReset 1.3.6.1.4.1.49.2.3.1.4.4.52.2.1.3
Used to reset the port's '802.3 state machine', which will re-enable a disabled port and/or reconnect a partitioned port.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER noReset(1), reset(2)  

ol41nnHMTPPortLinkInteg 1.3.6.1.4.1.49.2.3.1.4.4.52.2.1.4
The port's (good) link integrity configuration. Enabling link integrity configures the port to conform to the link integrity feature as specified by 10BASE-T. Applicable only to 10BASE-T ports.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2), notApplicable(3)  

ol41nnHETPModTable 1.3.6.1.4.1.49.2.3.1.4.4.53.1
A list of module-specific information associated with a particular ol41nnHETP module.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Ol41nnHETPModEntry

ol41nnHETPModEntry 1.3.6.1.4.1.49.2.3.1.4.4.53.1.1
A module entry containing objects that describe the module level for that particular module.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Ol41nnHETPModEntry  

ol41nnHETPModSlotIndex 1.3.6.1.4.1.49.2.3.1.4.4.53.1.1.1
The slot number of this module.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ol41nnHETPModSerialNo 1.3.6.1.4.1.49.2.3.1.4.4.53.1.1.2
The serial number of this module, as entered by the user through the Management interface.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

ol41nnHETPPortTable 1.3.6.1.4.1.49.2.3.1.4.4.53.2
A table of port-specific information for each port of this module type.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Ol41nnHETPPortEntry

ol41nnHETPPortEntry 1.3.6.1.4.1.49.2.3.1.4.4.53.2.1
A port entry containing objects that describe this port.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Ol41nnHETPPortEntry  

ol41nnHETPPortSlotIndex 1.3.6.1.4.1.49.2.3.1.4.4.53.2.1.1
The slot (stack) number of this port's module.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ol41nnHETPPortIndex 1.3.6.1.4.1.49.2.3.1.4.4.53.2.1.2
The port number of this port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ol41nnHETPPortReset 1.3.6.1.4.1.49.2.3.1.4.4.53.2.1.3
Used to reset the port's '802.3 state machine', which will re-enable a disabled port and/or reconnect a partitioned port.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER ready(1), reset(2)  

ol41nnHETPPortLinkInteg 1.3.6.1.4.1.49.2.3.1.4.4.53.2.1.4
The port's (good) link integrity configuration. Enabling link integrity configures the port to conform to the link integrity feature as specified by 10BASE-T.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

olModSummaryTable 1.3.6.1.4.1.49.2.3.1.4.5
A table of condensed module information.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    OlModSummaryEntry

olModSummaryEntry 1.3.6.1.4.1.49.2.3.1.4.5.1
A summary of all the generic and value added information associated with this module.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  OlModSummaryEntry  

olModSummarySlotIndex 1.3.6.1.4.1.49.2.3.1.4.5.1.1
The slot number of this module that this summary pertains to.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

olModSummaryInfo 1.3.6.1.4.1.49.2.3.1.4.5.1.2
A summary of all information relating to this module in condensed format. The condensed format is only as large as needed to hence the largest value which usually is one octet. The TCP port for the terminal server, however, uses 4 octets. The summary consists of a header, a module portion, a port portion, and a trunk portion. Each portion consists of generic information and module specific information. For example, the module information consists of the olModTable entry for this slot and the olSpecMods module table information for this module type for this slot. --------------------------------------------------- The header consists of the following octets: Version of structure : 1 Number of octets in generic module Number of octets in specific module Number of octets in generic port Number of octets in specific port Number of octets in generic trunk Number of octets in specific trunk The format of the data portion is as follows: Some of the olModTable: olModType olModClass olModDescr olModVersion olModNetwork olModNetworkType olModStatus olModNumPorts olModNumTrunks olSpecMods module table (for this module) Not including slot number. For each port: Some of the olPortTable: olPortType olPortConnector olPortStatus olPortAdminState olPortNetwork olPortNetworkType olPortAlertFilter olSpecMods port table (for this port's module) Not including slot and port number. For each trunk: Some of the olTrunkTable: olTrunkType olTrunkConnector olTrunkStatus olTrunkAdminState olTrunkWrapState olTrunkNeighbor olSpecMods trunk table (for this trunk's module) Not including slot and trunk number. --------------------------------------------------- Version 2 of the summary structure: Version 2 is returned only when there is a possibility of multiple modules per slot. This is a function of the platform (concentrator). The ONcore platform is an example of this. ONline modules in the ONcore platform will still be represented by version 1 structure. Version 2 is an array of version 1 structures, Version: 2 Maximum number of v1 structures = 8. Number of v1 structures to follow => max of 8. Reserved octet = 0. 2 octets each describing the length of v1 summaries: Number of octets in summary #1. Number of octets in summary #2. Number of octets in summary #3. Number of octets in summary #4. Number of octets in summary #5. Number of octets in summary #6. Number of octets in summary #7. Number of octets in summary #8. Array of Version 1 structures. For example, there are 3 modules in slot 5, in subslot locations 1, 3 and 8. Byte Description ---- ----------- 1 Version = 2 2 Max number of v1 structures (8) 3 Number of v1 structures (3) 4 Reserved (0) 5&6 Number of bytes N(1) 7&8 Number of bytes N(2) = 0 9&10 Number of bytes N(3) 11&12 Number of bytes N(4) = 0 13&14 Number of bytes N(4) = 0 15&16 Number of bytes N(4) = 0 17&18 Number of bytes N(4) = 0 19&20 Number of bytes N(4) 21 to Version 1 summary for module in sslot 1 21 + N(1) 21 + N(1) to Version 1 summary for module in sslot 3 (21 + N(1)) + N(3) (21 + N(1)) + N(3) to Version 1 summary for module in sslot 8 ((21 + N(1)) + N(3)) + N(8) 21 to 21 + N(1) Version 1 summary for module in sslot 1 ---------------------------------------------------- In all of the above, the index for all of these tables is condensed out of the summary.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(0..512)  

ocModTable 1.3.6.1.4.1.49.2.3.1.4.6
A table that contains generic information about every module that is present within the concentrator.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    OcModEntry

ocModEntry 1.3.6.1.4.1.49.2.3.1.4.6.1
A list of information for each module in the concentrator.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  OcModEntry  

ocModSlotIndex 1.3.6.1.4.1.49.2.3.1.4.6.1.1
The unique slot number of this module. Its value ranges between 1 and olConcNumSlots and remains constant at least from one re-initialization of the entity's network management system to the next re-initialization.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ocModSubSlotIndex 1.3.6.1.4.1.49.2.3.1.4.6.1.2
The unique subslot number of this module. Its value ranges between 1 and the value of ocModNumSubSlots for the mother board in this slot (ocModNumSubSlots..1), and it remains constant between re-initializations of the mother board. The mother board is ALWAYS the first subslot index in any particular slot. Not all subslots must be occupied, and an empty subslot will not return an instance.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ocModType 1.3.6.1.4.1.49.2.3.1.4.6.1.3
The unique type identifier for this module. This type is used to identify the branch in olSpecMods (see below). module-unmanageable(1) means that only the following objects are valid for this module: ocModSlotIndex ocModClass ocModVersion ocModVendor ocModReset ocModConfigToDips ocModConfigured module-unknown(2) means that all the generic attributes are manageable, but there is no olSpecMods branch for this module as viewed by this agent.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER module-unmanageable(1), module-unknown(2), module-50nnM-CTL(3), module-51nnM-MGT(4), module-51nnM-FIB(5), module-51nnM-UTP(6), module-51nnM-TP(7), module-51nnM-BNC(8), module-51nnB-EE(9), module-51nnR-ES(10), module-51nnR-EE(11), module-51nnM-AUIF(12), module-51nnM-AUIM(13), module-5208M-TP(14), module-51nnM-FP(15), module-51nnM-FBP(16), module-51nnM-TPL(17), module-51nnM-TPPL(18), module-52nnM-TP(19), module-52nnM-FR(20), module-51nnM-TS(21), module-51nnM-FL(22), module-50nnM-RCTL(23), module-51nnM-FB(24), module-53nnM-MGT(25), module-53nnM-FBMIC(26), module-53nnM-FIBST(27), module-53nnM-STP(28), module-51nnM-TPCL(29), module-52nnB-TT(30), module-51nnI-x(31), module-52nnM-MGT(32), module-50nnM-HCTL(33), module-61nnM-CAR(35), module-60nnM-MGT(43), module-61nnD-MGT(45), module-61nnM-FBP(46), module-61nnM-TPL(47), module-51nnM-TPLS(48), module-60nnM-RCTL(50), module-50nnM-RCLS(51), module-41nnH-MTP(52), module-41nnH-ETP(53), module-52nnM-EC(62), module-53nnM-TDDI(65)  

ocModClass 1.3.6.1.4.1.49.2.3.1.4.6.1.4
The class of this module. The class defines the internal data structure used to manage this module.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER controller(1), mgmt(2), ethernet-media(3), ethernet-interconnect(4), ethernet-portswitching-media(5), token-ring-media(6), terminal-server(7), fddi-media(8), token-ring-mgmt(9), ethernet-connswitching-media(10), token-ring-interconnect(11), fddi-mgmt(12), oncore-token-ring-media(13), ethernet-carrier(14), oncore-oem-specials(15), network-monitor(16), oncore-download(17), ethernet-media-extended(19), online-token-ring-mod-interconnect(20)  

ocModDescr 1.3.6.1.4.1.49.2.3.1.4.6.1.5
A textual string containing information about the module.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(1..128)  

ocModVersion 1.3.6.1.4.1.49.2.3.1.4.6.1.6
The software version number of this module.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(1..32)  

ocModVendor 1.3.6.1.4.1.49.2.3.1.4.6.1.7
The vendor of this module.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER chipcom(1), cisco(2), pilkington(3), datability(5), ibm(6), raycom(7), retix(8), intellicom(9)  

ocModResetModule 1.3.6.1.4.1.49.2.3.1.4.6.1.8
Setting this object to reset(2) causes this module to reset.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER noReset(1), reset(2)  

ocModConfigToDips 1.3.6.1.4.1.49.2.3.1.4.6.1.9
Setting this object to configure(2) causes this module to configure based on the dip switch settings. Note, if the NV dip switch (if applicable) is set to configure from NV, then the module will retrieve its configuration from the on-board non-volatile storage.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER noConfigure(1), configure(2)  

ocModConfigured 1.3.6.1.4.1.49.2.3.1.4.6.1.10
This object indicates whether this module has already been configured. An unconfigured module is configured to a safe state (ports are disabled and the module is isolated from the backplane networks).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER notConfigured(1), configured(2)  

ocModNetwork 1.3.6.1.4.1.49.2.3.1.4.6.1.11
The network that this module is attached to. Setting this module to a value that it does not support will return an invalidData error.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER other(1), isolated(2), port-switching(3), front-panel(5), ethernet-1(6), ethernet-2(7), ethernet-3(8), token-ring-1(9), token-ring-2(10), token-ring-3(11), token-ring-4(12), token-ring-5(13), token-ring-6(14), token-ring-7(15), fddi-1(16), fddi-2(17), fddi-3(18), fddi-4(19), per-connector(20), isolated-1(21), isolated-2(22), isolated-3(23), isolated-4(24), isolated-5(25), isolated-6(26), isolated-7(27), isolated-8(28), isolated-9(29), isolated-10(30), isolated-11(31), ethernet-4(32), ethernet-5(33), ethernet-6(34), ethernet-7(35), ethernet-8(36)  

ocModNetworkType 1.3.6.1.4.1.49.2.3.1.4.6.1.12
The network type of this module. The network type reflects the valid values for ocModNetwork.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(1), port-switching(3), ethernet(5), token-ring(6), fddi(7), serial(8)  

ocModStatus 1.3.6.1.4.1.49.2.3.1.4.6.1.13
The module's status.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER okay(1), fatalError(10), booting(20), partial-failure(21), notInserted(30), speedMismatch(31)  

ocModNumPorts 1.3.6.1.4.1.49.2.3.1.4.6.1.14
The number of ports on this module. Note, ports may be physical ports like 10BASE-T ports, or logical, like the bridge module ports.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ocModNumTrunks 1.3.6.1.4.1.49.2.3.1.4.6.1.15
The number of trunks on this module. Note, trunks are links that are, by definition, backbone connections. Examples of trunks are ring in and ring out ports for token ring, and the connections for rings to the backplane.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ocModNumSubSlots 1.3.6.1.4.1.49.2.3.1.4.6.1.16
The number of possible submodules that can exist in this slot.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

olNetDPTable 1.3.6.1.4.1.49.2.3.1.5.1.1
A table that contains information linking physical backplane allocation to logical networks. This information is useful: (1) to determine the physical allocation of networks on the backplane, and (2) to determine the remaining capacity of the backplane for future network growth. Since unknown modules are managed via dip switches, this is useful in order to set the dips to the appropriate settings. Ethernet is a bus architecture. Once a path is allocated, all modules and ports can access that path. Token Ring and FDDI are ring architectures. Each module on a ring requires a path. Therefore, 4 paths could be used to link 4 modules together on one ring, or 2 modules on 2 separate rings. It is possible to have a module allocated to a ring (and thus a data path) without linking to another module. These rules can be used to determine the remaining capacity for network growth.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    OlNetDPEntry

olNetDPEntry 1.3.6.1.4.1.49.2.3.1.5.1.1.1
A list of information about each data path in the concentrator.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  OlNetDPEntry  

olNetDPDataPath 1.3.6.1.4.1.49.2.3.1.5.1.1.1.1
The data path on the backplane. Data paths between different protocols overlap. That is, an ethernet data path will overlap with multiple token ring and fddi data paths.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ethernet-path-1(6), ethernet-path-2(7), ethernet-path-3(8), token-ring-path-1(9), token-ring-path-2(10), token-ring-path-3(11), token-ring-path-4(12), token-ring-path-5(13), token-ring-path-6(14), token-ring-path-7(15), token-ring-path-8(16), token-ring-path-9(17), token-ring-path-10(18), token-ring-path-11(19), token-ring-path-12(20), token-ring-path-13(21), token-ring-path-14(22), token-ring-path-15(23), fddi-path-1(24), fddi-path-2(25), fddi-path-3(26), fddi-path-4(27), fddi-path-5(28), fddi-path-6(29), fddi-path-7(30), fddi-path-8(31), ethernet-path-4(32), ethernet-path-5(33), ethernet-path-6(34), ethernet-path-7(35), ethernet-path-8(36)  

olNetDPNetID 1.3.6.1.4.1.49.2.3.1.5.1.1.1.2
The network that this data path corresponds to. If the data path is not being used at all, notUsed(1) is the return value. If the data path is being used by another protocol, then otherProto(2) is the return value.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER notUsed(1), otherProto(2), ethernet-1(6), ethernet-2(7), ethernet-3(8), token-ring-1(9), token-ring-2(10), token-ring-3(11), token-ring-4(12), token-ring-5(13), token-ring-6(14), token-ring-7(15), fddi-1(16), fddi-2(17), fddi-3(18), fddi-4(19)  

olNetSecurityMACTable 1.3.6.1.4.1.49.2.3.1.5.1.2
A table of security configuration parameters and MAC addresses associated with every port with security configured in the concentrator.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    OlNetSecurityMACEntry

olNetSecurityMACEntry 1.3.6.1.4.1.49.2.3.1.5.1.2.1
A list of security configuration parameters and MAC addresses associated with each port with security configured in the concentrator.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  OlNetSecurityMACEntry  

olNetSecurityMACSlotIndex 1.3.6.1.4.1.49.2.3.1.5.1.2.1.1
The slot number that contains this port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

olNetSecurityMACPortIndex 1.3.6.1.4.1.49.2.3.1.5.1.2.1.2
The port number within this slot.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

olNetSecurityMACAddress 1.3.6.1.4.1.49.2.3.1.5.1.2.1.3
The security MAC address assigned to this port.
Status: mandatory Access: read-write
OBJECT-TYPE    
  MacAddress  

olNetSecurityMACMode 1.3.6.1.4.1.49.2.3.1.5.1.2.1.4
The desired security mode for this port/address.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

olNetSecurityMACStatus 1.3.6.1.4.1.49.2.3.1.5.1.2.1.5
Each instance of the olNetSecurityMACTable associated with this olNetSecurityMACEntry (slot, port, and address) will be deleted by the agent if this olNetSecurityMACEntry is not equal to valid(1). Initial creation of instances occurs via a set operation on a specific slot/port/address.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

olNetOlSec 1.3.6.1.4.1.49.2.3.1.5.1.3
OBJECT IDENTIFIER    

olNetOlSecAddrTable 1.3.6.1.4.1.49.2.3.1.5.1.3.1
A table of security MAC addresses.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    OlNetOlSecAddrEntry

olNetOlSecAddrEntry 1.3.6.1.4.1.49.2.3.1.5.1.3.1.1
Security MAC addresses indexed by slot, port, and MAC address.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  OlNetOlSecAddrEntry  

olNetOlSecAddrSlotIndex 1.3.6.1.4.1.49.2.3.1.5.1.3.1.1.1
The slot number index (used along with the port and address indices).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

olNetOlSecAddrPortIndex 1.3.6.1.4.1.49.2.3.1.5.1.3.1.1.2
The port number index (used along with the slot and address indices).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

olNetOlSecAddrAddress 1.3.6.1.4.1.49.2.3.1.5.1.3.1.1.3
The security MAC address index (used along with the slot and port indices). Note that there may be multiple addresses associated with a single port.
Status: mandatory Access: read-write
OBJECT-TYPE    
  MacAddress  

olNetOlSecAddrStatus 1.3.6.1.4.1.49.2.3.1.5.1.3.1.1.4
Setting this object to valid(1) will cause the corresponding security MAC address to be associated with the given port. Setting this object to invalid(2) will clear the corresponding MAC address for the given port.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

olNetOlSecControlTable 1.3.6.1.4.1.49.2.3.1.5.1.3.2
A table of security configuration parameters pertaining to a specific port.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    OlNetOlSecControlEntry

olNetOlSecControlEntry 1.3.6.1.4.1.49.2.3.1.5.1.3.2.1
Security configuration parameters pertaining to a specific port (indexed by slot and port).
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  OlNetOlSecControlEntry  

olNetOlSecControlSlotIndex 1.3.6.1.4.1.49.2.3.1.5.1.3.2.1.1
The slot number index (used along with the port index).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

olNetOlSecControlPortIndex 1.3.6.1.4.1.49.2.3.1.5.1.3.2.1.2
The port number index (used along with the slot index).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

olNetOlSecControlMode 1.3.6.1.4.1.49.2.3.1.5.1.3.2.1.3
The desired security mode for this port. Setting this object to enable(1) is equivalent to setting the 'SecType' object (see below) to full(1), since both actions enable Eavesdropping and Intrusion Security.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

olNetOlSecControlSecType 1.3.6.1.4.1.49.2.3.1.5.1.3.2.1.4
Setting this object enables a certain type of security for this port: Eavesdropping Security-only, Intrusion Security-only, or Full. Note that setting this object to full(1) is equivalent to setting the 'Mode' object (see above) to enable(1).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER full(1), intrusion-only(2), eavesdropping-only(3), no-security(4)  

olNetOlSecControlActOnIntr 1.3.6.1.4.1.49.2.3.1.5.1.3.2.1.5
This object can be used to get or set the port-action-on- intrusion flag on a per-port basis. When an Intrusion Security breach is attempted on a port, the Security Module can automatically disable the port and/or generate a trap to management, as dictated by this flag.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER disable-and-trap(1), disable-only(2), trap-only(3), no-action(4)  

olNetOlSecControlClearAddrs 1.3.6.1.4.1.49.2.3.1.5.1.3.2.1.6
When this object is set to clear-all-addrs(1) then all of the security MAC addresses associated with this port will be cleared. Note that this will not change the state of the 'Mode' (or any other) object in this table.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER clear-all-addrs(1), not-clear(2)  

olNetOlSecControlAutolearnMask 1.3.6.1.4.1.49.2.3.1.5.1.3.2.1.7
This mask is used when autolearning is performed to determine whether the nMM should learn any security MAC addresses for this port. If this object is set to enable(1) then the nMM will ignore this port during autolearning. Note that autolearning is not supported by the TRMM.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

olNetOlSecAutolearn 1.3.6.1.4.1.49.2.3.1.5.1.3.3
OBJECT IDENTIFIER    

olNetOlSecAutolearnTrigger 1.3.6.1.4.1.49.2.3.1.5.1.3.3.1
When this object is set to autolearn(1) then the nMM will capture a snapshot of its MAC address cache for those ports whose 'AutolearnMask' object is disabled(2). This snapshot may be investigated and modified via the 'LearnTable' (see below). The snapshot of addresses may be downloaded to the Security Module via the 'Download' object (see below).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER autolearn(1), no-autolearn(2)  

olNetOlSecAutolearnDownload 1.3.6.1.4.1.49.2.3.1.5.1.3.3.2
When this object is set to download-addresses(1) then the nMM will download its snapshot of addresses to the Security Module.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER download-addresses(1), no-download(2)  

olNetOlSecLearnTable 1.3.6.1.4.1.49.2.3.1.5.1.3.4
A table of security MAC addresses which have been autolearned on the nMM by taking a snapshot of its MAC address cache.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    OlNetOlSecLearnEntry

olNetOlSecLearnEntry 1.3.6.1.4.1.49.2.3.1.5.1.3.4.1
Security MAC addresses which have been autolearned (indexed by slot, port, and address).
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  OlNetOlSecLearnEntry  

olNetOlSecLearnSlotIndex 1.3.6.1.4.1.49.2.3.1.5.1.3.4.1.1
The slot number index (used along with the port and address indices).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

olNetOlSecLearnPortIndex 1.3.6.1.4.1.49.2.3.1.5.1.3.4.1.2
The port number index (used along with the slot and address indices).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

olNetOlSecLearnAddress 1.3.6.1.4.1.49.2.3.1.5.1.3.4.1.3
The security MAC address index (used along with the slot and port indices). Note that there may be multiple addresses per port.
Status: mandatory Access: read-write
OBJECT-TYPE    
  MacAddress  

olNetOlSecLearnStatus 1.3.6.1.4.1.49.2.3.1.5.1.3.4.1.4
Setting this object to valid(1) will cause the corresponding security MAC address to be included in the snapshot of autolearned addresses. Setting this object to invalid(2) will clear the corresponding MAC address from the snapshot of autolearned addresses.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

olNetOlSecIntruderTable 1.3.6.1.4.1.49.2.3.1.5.1.3.5
A table of entries which describe Intrusion Security breach attempts. This table contains the same info as the following table, the difference being that this table is indexed by time only and the other is indexed by slot. port.time.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    OlNetOlSecIntruderEntry

olNetOlSecIntruderEntry 1.3.6.1.4.1.49.2.3.1.5.1.3.5.1
A table of entries which describe Intrusion Security breach attempts. The index is simply the chronological order in which the attempt occurred; e.g. index 1 corresponds to the first intrusion attempt, index 2 to the next one, and so on. Note that the the oldest entry will be deleted automatically when a new entry is added to a full table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  OlNetOlSecIntruderEntry  

olNetOlSecIntruderChronIndex 1.3.6.1.4.1.49.2.3.1.5.1.3.5.1.1
The chronological index into the Intruder Table. An index of 1 corresponds to the first Intrusion Security breach attempt, an index of 2 corresponds to the next attempt, etc. Note that the oldest entry will be deleted automatically when a new entry is added to a full table.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

olNetOlSecIntruderSlot 1.3.6.1.4.1.49.2.3.1.5.1.3.5.1.2
The slot number on which the intrusion attempt occurred.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

olNetOlSecIntruderPort 1.3.6.1.4.1.49.2.3.1.5.1.3.5.1.3
The port number on which the intrusion attempt occurred.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

olNetOlSecIntruderAddress 1.3.6.1.4.1.49.2.3.1.5.1.3.5.1.4
The address of the intruder, if known. If it is not known then this object will equal all zeroes.
Status: mandatory Access: read-only
OBJECT-TYPE    
  MacAddress  

olNetOlSecIntruderTimeSince 1.3.6.1.4.1.49.2.3.1.5.1.3.5.1.5
The time in hundredths of a second since the Intrusion Security breach attempt took place. For example, if it is equal to 500 ticks then the intrusion attempt occurred 5 seconds ago.
Status: mandatory Access: read-only
OBJECT-TYPE    
  TimeTicks  

olNetOlSecIntruderDisabled 1.3.6.1.4.1.49.2.3.1.5.1.3.5.1.6
This object indicates whether the port on which the intrusion attempt took place was automatically disabled.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER auto-disabled(1), not-auto-disabled(2)  

olNetOlSecPortIntrTable 1.3.6.1.4.1.49.2.3.1.5.1.3.6
A table of entries which describe Intrusion Security breach attempts. This table contains the same info as the previous table, the difference being the indices used to access the data.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    OlNetOlSecPortIntrEntry

olNetOlSecPortIntrEntry 1.3.6.1.4.1.49.2.3.1.5.1.3.6.1
A table of entries which describe Intrusion Security breach attempts. The indices are the slot, port, and chronological order in time of the intrusion attempt.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  OlNetOlSecPortIntrEntry  

olNetOlSecPortIntrSlotIndex 1.3.6.1.4.1.49.2.3.1.5.1.3.6.1.1
The slot number on which the intrusion attempt occurred.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

olNetOlSecPortIntrPortIndex 1.3.6.1.4.1.49.2.3.1.5.1.3.6.1.2
The port number on which the intrusion attempt occurred.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

olNetOlSecPortIntrChronIndex 1.3.6.1.4.1.49.2.3.1.5.1.3.6.1.3
The chronological index into the Intruder Table. An index of 1 corresponds to the first Intrusion Security breach attempt for that port, an index of 2 corresponds to the next attempt, etc. Note that the oldest overall entry (regardless of slot and port) will be deleted automatically when a new entry is added to a full table.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

olNetOlSecPortIntrAddress 1.3.6.1.4.1.49.2.3.1.5.1.3.6.1.4
The address of the intruder, if known. If it is not known then this object will equal all zeroes.
Status: mandatory Access: read-only
OBJECT-TYPE    
  MacAddress  

olNetOlSecPortIntrTimeSince 1.3.6.1.4.1.49.2.3.1.5.1.3.6.1.5
The time in hundredths of a second since the Intrusion Security breach attempt took place. For example, if it is equal to 500 ticks then the intrusion attempt occurred 5 seconds ago.
Status: mandatory Access: read-only
OBJECT-TYPE    
  TimeTicks  

olNetOlSecPortIntrDisabled 1.3.6.1.4.1.49.2.3.1.5.1.3.6.1.6
This object indicates whether the port on which the intrusion attempt took place was automatically disabled.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER auto-disabled(1), not-auto-disabled(2)  

olNetOlSecTrap 1.3.6.1.4.1.49.2.3.1.5.1.3.7
OBJECT IDENTIFIER    

olNetOlSecTrapReason 1.3.6.1.4.1.49.2.3.1.5.1.3.7.1
This object is included in security traps to specify the reason for the trap. When this object is read it will represent the reason for the most recently generated security trap. If this object is read before any security traps have been generated then the value not-applicable(1) will be returned.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER not-applicable(1), intrusion-attempt(2)  

olEnetStatsTable 1.3.6.1.4.1.49.2.3.1.5.2.1
A table that contains statistical information about Ethernet (IEEE 802.3) networks.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    OlEnetStatsEntry

olEnetStatsEntry 1.3.6.1.4.1.49.2.3.1.5.2.1.1
A list of statistical information about each Ethernet (IEEE 802.3) network in the concentrator.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  OlEnetStatsEntry  

olEnetStatsNetID 1.3.6.1.4.1.49.2.3.1.5.2.1.1.1
The network index that uniquely identifies this network.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ethernet-1(6), ethernet-2(7), ethernet-3(8), ethernet-4(32), ethernet-5(33), ethernet-6(34), ethernet-7(35), ethernet-8(36)  

olEnetStatsFramesRcvdOks 1.3.6.1.4.1.49.2.3.1.5.2.1.1.2
The count of frames that were successfully received by this network. This counter does not include frames received in error.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

olEnetStatsOctetsRcvdOks 1.3.6.1.4.1.49.2.3.1.5.2.1.1.3
The count of the number of octets that were successfully received by this network. This counter does not include octets that were part of frames that were received in error.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

olEnetStatsMcastRcvdOks 1.3.6.1.4.1.49.2.3.1.5.2.1.1.4
The count of the number of multicast frames successfully received by this network.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

olEnetStatsBcastRcvdOks 1.3.6.1.4.1.49.2.3.1.5.2.1.1.5
The count of the number of broadcast frames successfully received by this network.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

olEnetStatsFrameTooLongs 1.3.6.1.4.1.49.2.3.1.5.2.1.1.6
The count of the number of frames received by this network that exceeds the maximum permitted Ethernet (802.3) frame size.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

olEnetStatsAlignmentErrors 1.3.6.1.4.1.49.2.3.1.5.2.1.1.7
The count of the number of frames received by this network that did not pass the frame check sequence (FCS) check and that are not an integral number of octets. These frames are not counted in olEnetStatsFCSErrors.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

olEnetStatsFCSErrors 1.3.6.1.4.1.49.2.3.1.5.2.1.1.8
The count of the number of frames received by this network that did not pass the frame check sequence (FCS) check and are an integral number of octets.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

olEnetStatsRunts 1.3.6.1.4.1.49.2.3.1.5.2.1.1.9
The count of the number of frames received by this network that are less than 512 bits long.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

olEnetStatsLocalColls 1.3.6.1.4.1.49.2.3.1.5.2.1.1.10
The count of the number of times that two or more ports within this concentrator have received traffic simultaneously.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

olEnetStatsDropEvents 1.3.6.1.4.1.49.2.3.1.5.2.1.1.11
The total number of events in which frames were dropped due to lack of resources. Note that this number is not necessarily the number of frames dropped; it is just the number of times this condition has been detected.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

olEnetStatsModTable 1.3.6.1.4.1.49.2.3.1.5.2.2
A table of statistical information counted for each module in each Ethernet (IEEE 802.3) network.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    OlEnetStatsModEntry

olEnetStatsModEntry 1.3.6.1.4.1.49.2.3.1.5.2.2.1
A list of statistical information for each port on each Ethernet (IEEE 802.3) network in the concentrator.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  OlEnetStatsModEntry  

olEnetStatsModNetID 1.3.6.1.4.1.49.2.3.1.5.2.2.1.1
The unique identifier for this network.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ethernet-1(6), ethernet-2(7), ethernet-3(8)  

olEnetStatsModSlotIndex 1.3.6.1.4.1.49.2.3.1.5.2.2.1.2
The slot number that contains this module.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

olEnetStatsModFramesRcvdOks 1.3.6.1.4.1.49.2.3.1.5.2.2.1.3
The count of frames that were successfully received by this module. This counter does not include frames received in error.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

olEnetStatsModOctetsRcvdOks 1.3.6.1.4.1.49.2.3.1.5.2.2.1.4
The count of the number of octets that were successfully received by this module. This counter does not include octets that were part of frames that were received in error.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

olEnetStatsModMcastRcvdOks 1.3.6.1.4.1.49.2.3.1.5.2.2.1.5
The count of the number of multicast frames successfully received by this module.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

olEnetStatsModBcastRcvdOks 1.3.6.1.4.1.49.2.3.1.5.2.2.1.6
The count of the number of broadcast frames successfully received by this module.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

olEnetStatsModFrameTooLongs 1.3.6.1.4.1.49.2.3.1.5.2.2.1.7
The count of the number of frames received by this module that exceeds the maximum permitted Ethernet (802.3) frame size.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

olEnetStatsModAlignmentErrors 1.3.6.1.4.1.49.2.3.1.5.2.2.1.8
The count of the number of frames received by this module that did not pass the frame check sequence (FCS) check and that are not an integral number of octets. These frames are not counted in olEnetStatsModFCSErrors.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

olEnetStatsModFCSErrors 1.3.6.1.4.1.49.2.3.1.5.2.2.1.9
The count of the number of frames received by this module that did not pass the frame check sequence (FCS) check and are an integral number of octets.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

olEnetStatsModRunts 1.3.6.1.4.1.49.2.3.1.5.2.2.1.10
The count of the number of frames received by this module that are less than 512 bits long.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

olEnetStatsPortTable 1.3.6.1.4.1.49.2.3.1.5.2.3
A table of statistical information counted for each port in each Ethernet (IEEE 802.3) network.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    OlEnetStatsPortEntry

olEnetStatsPortEntry 1.3.6.1.4.1.49.2.3.1.5.2.3.1
A list of statistical information for each port on each Ethernet (IEEE 802.3) network in the concentrator.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  OlEnetStatsPortEntry  

olEnetStatsPortNetID 1.3.6.1.4.1.49.2.3.1.5.2.3.1.1
The unique identifier for this network.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ethernet-1(6), ethernet-2(7), ethernet-3(8), ethernet-4(32), ethernet-5(33), ethernet-6(34), ethernet-7(35), ethernet-8(36)  

olEnetStatsPortSlotIndex 1.3.6.1.4.1.49.2.3.1.5.2.3.1.2
The slot number that contains this port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

olEnetStatsPortIndex 1.3.6.1.4.1.49.2.3.1.5.2.3.1.3
The port number within this slot.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

olEnetStatsPortFramesRcvdOks 1.3.6.1.4.1.49.2.3.1.5.2.3.1.4
The count of frames that were successfully received by this port. This counter does not include frames received in error.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

olEnetStatsPortOctetsRcvdOks 1.3.6.1.4.1.49.2.3.1.5.2.3.1.5
The count of the number of octets that were successfully received by this port. This counter does not include octets that were part of frames that were received in error.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

olEnetStatsPortMcastRcvdOks 1.3.6.1.4.1.49.2.3.1.5.2.3.1.6
The count of the number of multicast frames successfully received by this port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

olEnetStatsPortBcastRcvdOks 1.3.6.1.4.1.49.2.3.1.5.2.3.1.7
The count of the number of broadcast frames successfully received by this port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

olEnetStatsPortFrameTooLongs 1.3.6.1.4.1.49.2.3.1.5.2.3.1.8
The count of the number of frames received by this port that exceeds the maximum permitted Ethernet (802.3) frame size.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

olEnetStatsPortAlignmentErrors 1.3.6.1.4.1.49.2.3.1.5.2.3.1.9
The count of the number of frames received by this port that did not pass the frame check sequence (FCS) check and that are not an integral number of octets. These frames are not counted in olEnetStatsPortFCSErrors.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

olEnetStatsPortFCSErrors 1.3.6.1.4.1.49.2.3.1.5.2.3.1.10
The count of the number of frames received by this port that did not pass the frame check sequence (FCS) check and are an integral number of octets.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

olEnetStatsPortRunts 1.3.6.1.4.1.49.2.3.1.5.2.3.1.11
The count of the number of frames received by this port that are less than 512 bits long.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

olEnetStatsPortSrcAddrChanges 1.3.6.1.4.1.49.2.3.1.5.2.3.1.12
The count of the number of times that olEnetStatsPortLastSourceAddr { olEnetStatsPortEntry 11 } has changed.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

olEnetStatsPortLastSrcAddr 1.3.6.1.4.1.49.2.3.1.5.2.3.1.13
The last source address seen on this port for this network for the last successfully received frame.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(6)  

olEnetStatsPortLastErrAddr 1.3.6.1.4.1.49.2.3.1.5.2.3.1.14
The value stored in the source address portion of a frame received in error (alignment, FCS, or too long). Since the frame was received in error, there is no guarantee that this is an actual valid address.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(6)  

olEnetMapTable 1.3.6.1.4.1.49.2.3.1.5.2.4
A table that contains a cache of information relating an Ethernet source address with a specific port for a given network. An indication of this source's utilization of the network is also provided.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    OlEnetMapEntry

olEnetMapEntry 1.3.6.1.4.1.49.2.3.1.5.2.4.1
A list of information that tracks a source address to a specific port for each network.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  OlEnetMapEntry  

olEnetMapNetID 1.3.6.1.4.1.49.2.3.1.5.2.4.1.1
The network index that uniquely identifies this network.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ethernet-1(6), ethernet-2(7), ethernet-3(8), ethernet-4(32), ethernet-5(33), ethernet-6(34), ethernet-7(35), ethernet-8(36)  

olEnetMapAddress 1.3.6.1.4.1.49.2.3.1.5.2.4.1.2
An Ethernet source address received by this port on this network.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(6)  

olEnetMapSlotIndex 1.3.6.1.4.1.49.2.3.1.5.2.4.1.3
The slot number of the port that received this address.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

olEnetMapPortIndex 1.3.6.1.4.1.49.2.3.1.5.2.4.1.4
The port number within olEnetMapSlotIndex's slot that received this address.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

olEnetMapFrames 1.3.6.1.4.1.49.2.3.1.5.2.4.1.5
An estimated count of the number of frames generated by this address. This count should be interpreted as an indicator, not a true frame count.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

olEnetMapOctets 1.3.6.1.4.1.49.2.3.1.5.2.4.1.6
An estimated count of the number of octets generated by this address. This count should be interpreted as an indicator, not a true octet count.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

olEnetMapTime 1.3.6.1.4.1.49.2.3.1.5.2.4.1.7
The time in in hundredths of a second since this address was last seen. For example, if olEnetMapTime is 500 ticks, then this adddress was seen 5 seconds ago.
Status: mandatory Access: read-only
OBJECT-TYPE    
  TimeTicks  

chipSnmpDot3RptrMgt 1.3.6.1.4.1.49.2.3.1.5.2.5
OBJECT IDENTIFIER    

chipRptrBasicPackage 1.3.6.1.4.1.49.2.3.1.5.2.5.1
OBJECT IDENTIFIER    

chipRptrMonitorPackage 1.3.6.1.4.1.49.2.3.1.5.2.5.2
OBJECT IDENTIFIER    

chipRptrAddrTrackPackage 1.3.6.1.4.1.49.2.3.1.5.2.5.3
OBJECT IDENTIFIER    

chipRptrRptrInfo 1.3.6.1.4.1.49.2.3.1.5.2.5.1.1
OBJECT IDENTIFIER    

chipRptrGroupInfo 1.3.6.1.4.1.49.2.3.1.5.2.5.1.2
OBJECT IDENTIFIER    

chipRptrPortInfo 1.3.6.1.4.1.49.2.3.1.5.2.5.1.3
OBJECT IDENTIFIER    

chipRptrMonitorRptrInfo 1.3.6.1.4.1.49.2.3.1.5.2.5.2.1
OBJECT IDENTIFIER    

chipRptrMonitorGroupInfo 1.3.6.1.4.1.49.2.3.1.5.2.5.2.2
OBJECT IDENTIFIER    

chipRptrMonitorPortInfo 1.3.6.1.4.1.49.2.3.1.5.2.5.2.3
OBJECT IDENTIFIER    

chipRptrAddrTrackRptrInfo 1.3.6.1.4.1.49.2.3.1.5.2.5.3.1
OBJECT IDENTIFIER    

chipRptrAddrTrackGroupInfo 1.3.6.1.4.1.49.2.3.1.5.2.5.3.2
OBJECT IDENTIFIER    

chipRptrAddrTrackPortInfo 1.3.6.1.4.1.49.2.3.1.5.2.5.3.3
OBJECT IDENTIFIER    

chipRptrRptrInfoTable 1.3.6.1.4.1.49.2.3.1.5.2.5.1.1.1
Table of descriptive and status information about the repeater.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ChipRptrRptrInfoEntry

chipRptrRptrInfoEntry 1.3.6.1.4.1.49.2.3.1.5.2.5.1.1.1.1
An entry in the table, containing information about a repeater.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  ChipRptrRptrInfoEntry  

chipRptrRptrInfoSlotIndex 1.3.6.1.4.1.49.2.3.1.5.2.5.1.1.1.1.1
The slot number of the repeater module on which the isolated network identified by chipRptrRptrInfoNetID resides. If chipRptrRptrInfoNetID does not identify an isolated network, then the value of this object is backplane(255).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER slot-1(1), slot-2(2), slot-3(3), slot-4(4), slot-5(5), slot-6(6), slot-7(7), slot-8(8), slot-9(9), slot-10(10), slot-11(11), slot-12(12), slot-13(13), slot-14(14), slot-15(15), slot-16(16), slot-17(17), backplane(255)  

chipRptrRptrInfoNetID 1.3.6.1.4.1.49.2.3.1.5.2.5.1.1.1.1.2
The network index that uniquely identifies this repeater.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ethernet-1(6), ethernet-2(7), ethernet-3(8), ethernet-4(32), ethernet-5(33), ethernet-6(34), ethernet-7(35), ethernet-8(36)  

chipRptrGroupCapacity 1.3.6.1.4.1.49.2.3.1.5.2.5.1.1.1.1.3
The chipRptrGroupCapacity is the number of groups that can be contained within the repeater. Within each managed repeater, the groups are uniquely numbered in the range from 1 to chipRptrGroupCapacity. Some groups may not be present in the repeater, in which case the actual number of groups present will be less than chipRptrGroupCapacity. The number of groups present will never be greater than chipRptrGroupCapacity. Note: In practice, this will generally be the number of field-replaceable units (i.e., modules, cards, or boards) that can fit in the physical repeater enclosure, and the group numbers will correspond to numbers marked on the physical enclosure.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..1024  

chipRptrOperStatus 1.3.6.1.4.1.49.2.3.1.5.2.5.1.1.1.1.4
The chipRptrOperStatus object indicates the operational state of the repeater. The chipRptrHealthText object may be consulted for more specific information about the state of the repeater's health. In the case of multiple kinds of failures (e.g., repeater failure and port failure), the value of this attribute shall reflect the highest priority failure in the following order: chipRptrFailure(3) groupFailure(4) portFailure(5) generalFailure(6).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(1), ok(2), rptrFailure(3), groupFailure(4), portFailure(5), generalFailure(6)  

chipRptrHealthText 1.3.6.1.4.1.49.2.3.1.5.2.5.1.1.1.1.5
The health text object is a text string that provides information relevant to the operational state of the repeater. Agents may use this string to provide detailed information on current failures, including how they were detected, and/or instructions for problem resolution. The contents are agent-specific.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

chipRptrReset 1.3.6.1.4.1.49.2.3.1.5.2.5.1.1.1.1.6
Setting this object to reset(2) causes a transition to the START state of Fig 9-2 in section 9 [IEEE 802.3 Std]. Setting this object to noReset(1) has no effect. The agent will always return the value noReset(1) when this object is read. This action does not reset the management counters defined in this document nor does it affect the portAdminStatus parameters. Included in this action is the execution of a disruptive Self-Test with the following characteristics: a) The nature of the tests is not specified. b) The test resets the repeater but without affecting management information about the repeater. c) The test does not inject packets onto any segment. d) Packets received during the test may or may not be transferred. e) The test does not interfere with management functions. As a result of this action a chipRptrResetEvent trap should be sent.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER noReset(1), reset(2)  

chipRptrNonDisruptTest 1.3.6.1.4.1.49.2.3.1.5.2.5.1.1.1.1.7
Setting this object to selfTest(2) causes the repeater to perform a agent-specific, non- disruptive self-test that has the following characteristics: a) The nature of the tests is not specified. b) The test does not change the state of the repeater or management information about the repeater. c) The test does not inject packets onto any segment. d) The test does not prevent the relay of any packets. e) The test does not interfere with management functions. After performing this test the agent will update the repeater health information and send a chipRptrHealth trap. Setting this object to noSelfTest(1) has no effect. The agent will always return the value noSelfTest(1) when this object is read.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER noSelfTest(1), selfTest(2)  

chipRptrTotalPartitionedPorts 1.3.6.1.4.1.49.2.3.1.5.2.5.1.1.1.1.8
This object returns the total number of ports in the repeater whose current state meets all three of the following criteria: chipRptrPortOperStatus does not have the value notPresent(3), chipRptrPortAdminStatus is enabled(1), and chipRptrPortAutoPartitionState is autoPartitioned(2).
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

chipRptrGroupTable 1.3.6.1.4.1.49.2.3.1.5.2.5.1.2.1
Table of descriptive and status information about the groups of ports.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ChipRptrGroupEntry

chipRptrGroupEntry 1.3.6.1.4.1.49.2.3.1.5.2.5.1.2.1.1
An entry in the table, containing information about a single group of ports.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  ChipRptrGroupEntry  

chipRptrGroupSlotIndex 1.3.6.1.4.1.49.2.3.1.5.2.5.1.2.1.1.1
The slot number of the repeater module on which the isolated network identified by chipRptrGroupNetID resides. If chipRptrGroupNetID does not identify an isolated network, then the value of this object is backplane(255).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER slot-1(1), slot-2(2), slot-3(3), slot-4(4), slot-5(5), slot-6(6), slot-7(7), slot-8(8), slot-9(9), slot-10(10), slot-11(11), slot-12(12), slot-13(13), slot-14(14), slot-15(15), slot-16(16), slot-17(17), backplane(255)  

chipRptrGroupNetID 1.3.6.1.4.1.49.2.3.1.5.2.5.1.2.1.1.2
The network index that uniquely identifies this group's repeater.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ethernet-1(6), ethernet-2(7), ethernet-3(8), ethernet-4(32), ethernet-5(33), ethernet-6(34), ethernet-7(35), ethernet-8(36)  

chipRptrGroupIndex 1.3.6.1.4.1.49.2.3.1.5.2.5.1.2.1.1.3
This object identifies the group within the repeater for which this entry contains information. This value is never greater than chipRptrGroupCapacity.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..1024  

chipRptrGroupDescr 1.3.6.1.4.1.49.2.3.1.5.2.5.1.2.1.1.4
A textual description of the group. This value should include the full name and version identification of the group's hardware type and indicate how the group is differentiated from other groups in the repeater. Plug-in Module, Rev A' or 'Barney Rubble 10BASE-T 4-port SIMM socket Version 2.1' are examples of valid group descriptions. It is mandatory that this only contain printable ASCII characters.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

chipRptrGroupObjectID 1.3.6.1.4.1.49.2.3.1.5.2.5.1.2.1.1.5
The vendor's authoritative identification of the group. This value is allocated within the SMI enterprises subtree (1.3.6.1.4.1) and provides a straight-forward and unambiguous means for determining what kind of group is being managed. For example, this object could take the value 1.3.6.1.4.1.4242.1.2.14 if vendor 'Flintstones, Inc.' was assigned the subtree 1.3.6.1.4.1.4242, and had assigned the identifier 1.3.6.1.4.1.4242.1.2.14 to its 'Wilma Flintstone 6-Port FOIRL Plug-in Module.'
Status: mandatory Access: read-only
OBJECT-TYPE    
  OBJECT IDENTIFIER  

chipRptrGroupOperStatus 1.3.6.1.4.1.49.2.3.1.5.2.5.1.2.1.1.6
An object that indicates the operational status of the group. A status of notPresent(4) indicates that the group is temporarily or permanently physically and/or logically not a part of the repeater. It is an implementation-specific matter as to whether the agent effectively removes notPresent entries from the table. A status of operational(2) indicates that the group is functioning, and a status of malfunctioning(3) indicates that the group is malfunctioning in some way.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(1), operational(2), malfunctioning(3), notPresent(4), underTest(5), resetInProgress(6)  

chipRptrGroupLastOperStatusChange 1.3.6.1.4.1.49.2.3.1.5.2.5.1.2.1.1.7
An object that contains the value of sysUpTime at the time that the value of the chipRptrGroupOperStatus object for this group last changed. A value of zero indicates that the group's oper status has not changed since the agent last restarted.
Status: mandatory Access: read-only
OBJECT-TYPE    
  TimeTicks  

chipRptrGroupPortCapacity 1.3.6.1.4.1.49.2.3.1.5.2.5.1.2.1.1.8
The chipRptrGroupPortCapacity is the number of ports that can be contained within the group. Valid range is 1-1024. Within each group, the ports are uniquely numbered in the range from 1 to chipRptrGroupPortCapacity. Note: In practice, this will generally be the number of ports on a module, card, or board, and the port numbers will correspond to numbers marked on the physical embodiment.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..1024  

chipRptrPortTable 1.3.6.1.4.1.49.2.3.1.5.2.5.1.3.1
Table of descriptive and status information about the ports.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ChipRptrPortEntry

chipRptrPortEntry 1.3.6.1.4.1.49.2.3.1.5.2.5.1.3.1.1
An entry in the table, containing information about a single port.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  ChipRptrPortEntry  

chipRptrPortSlotIndex 1.3.6.1.4.1.49.2.3.1.5.2.5.1.3.1.1.1
The slot number of the repeater module on which the isolated network identified by chipRptrPortNetID resides. If chipRptrPortNetID does not identify an isolated network, then the value of this object is backplane(255).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER slot-1(1), slot-2(2), slot-3(3), slot-4(4), slot-5(5), slot-6(6), slot-7(7), slot-8(8), slot-9(9), slot-10(10), slot-11(11), slot-12(12), slot-13(13), slot-14(14), slot-15(15), slot-16(16), slot-17(17), backplane(255)  

chipRptrPortNetID 1.3.6.1.4.1.49.2.3.1.5.2.5.1.3.1.1.2
The network index that uniquely identifies this port's repeater.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ethernet-1(6), ethernet-2(7), ethernet-3(8), ethernet-4(32), ethernet-5(33), ethernet-6(34), ethernet-7(35), ethernet-8(36)  

chipRptrPortGroupIndex 1.3.6.1.4.1.49.2.3.1.5.2.5.1.3.1.1.3
This object identifies the group containing the port for which this entry contains information.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..1024  

chipRptrPortIndex 1.3.6.1.4.1.49.2.3.1.5.2.5.1.3.1.1.4
This object identifies the port within the group for which this entry contains information. This value can never be greater than chipRptrGroupPortCapacity for the associated group.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..1024  

chipRptrPortAdminStatus 1.3.6.1.4.1.49.2.3.1.5.2.5.1.3.1.1.5
Setting this object to disabled(2) disables the port. A disabled port neither transmits nor receives. Once disabled, a port must be explicitly enabled to restore operation. A port which is disabled when power is lost or when a reset is exerted shall remain disabled when normal operation resumes. When the logical port is actually a daughterboard on the module, the AdminStatus directly relates to the interface mode of the daughterboard. Setting it enabled(1) enables the interface and likewise disabled(2) disables the interface mode. The admin status takes precedence over auto- partition and functionally operates between the auto-partition mechanism and the AUI/PMA. Setting this object to enabled(1) enables the port and exerts a BEGIN on the port's auto-partition state machine. (In effect, when a port is disabled, the value of chipRptrPortAutoPartitionState for that port is frozen until the port is next enabled. When the port becomes enabled, the chipRptrPortAutoPartitionState becomes notAutoPartitioned(1), regardless of its pre-disabling state.)
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

chipRptrPortAutoPartitionState 1.3.6.1.4.1.49.2.3.1.5.2.5.1.3.1.1.6
The autoPartitionState flag indicates whether the port is currently partitioned by the repeater's auto-partition protection. The conditions that cause port partitioning are specified in partition state machine in Section 9 [IEEE 802.3 Std]. They are not differentiated here.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER notAutoPartitioned(1), autoPartitioned(2)  

chipRptrPortOperStatus 1.3.6.1.4.1.49.2.3.1.5.2.5.1.3.1.1.7
This object indicates the port's operational status. The notPresent(3) status indicates the port is physically removed (note this may or may not be possible depending on the type of port.) The operational(1) status indicates that the port is enabled (see chipRptrPortAdminStatus) and working, even though it might be auto-partitioned (see chipRptrPortAutoPartitionState). If this object has the value operational(1) and chipRptrPortAdminStatus is set to disabled(2), it is expected that this object's value will change to notOperational(2) soon after.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER operational(1), notOperational(2), notPresent(3)  

chipRptrMonitorRptrTable 1.3.6.1.4.1.49.2.3.1.5.2.5.2.1.1
Table of performance and error statistics for the Repeater.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ChipRptrMonitorRptrEntry

chipRptrMonitorRptrEntry 1.3.6.1.4.1.49.2.3.1.5.2.5.2.1.1.1
An entry in the table, containing total performance and error statistics for a repeater.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  ChipRptrMonitorRptrEntry  

chipRptrMonitorSlotIndex 1.3.6.1.4.1.49.2.3.1.5.2.5.2.1.1.1.1
The slot number of the repeater module on which the isolated network identified by chipRptrMonitorNetID resides. If chipRptrMonitorNetID does not identify an isolated network, then the value of this object is backplane(255).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER slot-1(1), slot-2(2), slot-3(3), slot-4(4), slot-5(5), slot-6(6), slot-7(7), slot-8(8), slot-9(9), slot-10(10), slot-11(11), slot-12(12), slot-13(13), slot-14(14), slot-15(15), slot-16(16), slot-17(17), backplane(255)  

chipRptrMonitorNetID 1.3.6.1.4.1.49.2.3.1.5.2.5.2.1.1.1.2
The network index that uniquely identifies this repeater.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ethernet-1(6), ethernet-2(7), ethernet-3(8), ethernet-4(32), ethernet-5(33), ethernet-6(34), ethernet-7(35), ethernet-8(36)  

chipRptrMonitorTransmitCollisions 1.3.6.1.4.1.49.2.3.1.5.2.5.2.1.1.1.3
This counter is incremented every time the repeater state machine enters the TRANSMIT COLLISION state from any state other than ONE PORT LEFT (Ref: Fig 9-2, IEEE 802.3 Std). The approximate minimum time for rollover of this counter is 16 hours.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

chipRptrMonitorGroupTable 1.3.6.1.4.1.49.2.3.1.5.2.5.2.2.1
Table of performance and error statistics for the groups.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ChipRptrMonitorGroupEntry

chipRptrMonitorGroupEntry 1.3.6.1.4.1.49.2.3.1.5.2.5.2.2.1.1
An entry in the table, containing total performance and error statistics for a single group. Regular retrieval of the information in this table provides a means of tracking the performance and health of the networked devices attached to this group's ports. The counters in this table are redundant in the sense that they are the summations of information already available through other objects. However, these sums provide a considerable optimization of network management traffic over the otherwise necessary retrieval of the individual counters included in each sum.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  ChipRptrMonitorGroupEntry  

chipRptrMonitorGroupSlotIndex 1.3.6.1.4.1.49.2.3.1.5.2.5.2.2.1.1.1
The slot number of the repeater module on which the isolated network identified by chipRptrMonitorGroupNetID resides. If chipRptrMonitorGroupNetID does not identify an isolated network, then the value of this object is backplane(255).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER slot-1(1), slot-2(2), slot-3(3), slot-4(4), slot-5(5), slot-6(6), slot-7(7), slot-8(8), slot-9(9), slot-10(10), slot-11(11), slot-12(12), slot-13(13), slot-14(14), slot-15(15), slot-16(16), slot-17(17), backplane(255)  

chipRptrMonitorGroupNetID 1.3.6.1.4.1.49.2.3.1.5.2.5.2.2.1.1.2
The network index that uniquely identifies this group's repeater.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ethernet-1(6), ethernet-2(7), ethernet-3(8), ethernet-4(32), ethernet-5(33), ethernet-6(34), ethernet-7(35), ethernet-8(36)  

chipRptrMonitorGroupIndex 1.3.6.1.4.1.49.2.3.1.5.2.5.2.2.1.1.3
This object identifies the group within the repeater for which this entry contains information.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..1024  

chipRptrMonitorGroupTotalFrames 1.3.6.1.4.1.49.2.3.1.5.2.5.2.2.1.1.4
The total number of frames of valid frame length that have been received on the ports in this group. This counter is the summation of the values of the chipRptrMonitorPortReadableFrames counters for all of the ports in the group. This statistic provides one of the parameters necessary for obtaining the packet error rate. The approximate minimum time for rollover of this counter is 80 hours.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

chipRptrMonitorGroupTotalOctets 1.3.6.1.4.1.49.2.3.1.5.2.5.2.2.1.1.5
The total number of octets contained in the valid frames that have been received on the ports in this group. This counter is the summation of the values of the chipRptrMonitorPortReadableOctets counters for all of the ports in the group. This statistic provides an indicator of the total data transferred. The approximate minimum time for rollover of this counter is 58 minutes.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

chipRptrMonitorGroupTotalErrors 1.3.6.1.4.1.49.2.3.1.5.2.5.2.2.1.1.6
The total number of errors which have occurred on all of the ports in this group. This counter is the summation of the values of the chipRptrMonitorPortTotalErrors counters for all of the ports in the group.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

chipRptrMonitorPortTable 1.3.6.1.4.1.49.2.3.1.5.2.5.2.3.1
Table of performance and error statistics for the ports.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ChipRptrMonitorPortEntry

chipRptrMonitorPortEntry 1.3.6.1.4.1.49.2.3.1.5.2.5.2.3.1.1
An entry in the table, containing performance and error statistics for a single port.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  ChipRptrMonitorPortEntry  

chipRptrMonitorPortSlotIndex 1.3.6.1.4.1.49.2.3.1.5.2.5.2.3.1.1.1
The slot number of the repeater module on which the isolated network identified by chipRptrMonitorPortNetID resides. If chipRptrMonitorPortNetID does not identify an isolated network, then the value of this object is backplane(255).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER slot-1(1), slot-2(2), slot-3(3), slot-4(4), slot-5(5), slot-6(6), slot-7(7), slot-8(8), slot-9(9), slot-10(10), slot-11(11), slot-12(12), slot-13(13), slot-14(14), slot-15(15), slot-16(16), slot-17(17), backplane(255)  

chipRptrMonitorPortNetID 1.3.6.1.4.1.49.2.3.1.5.2.5.2.3.1.1.2
The network index that uniquely identifies this port's repeater.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ethernet-1(6), ethernet-2(7), ethernet-3(8), ethernet-4(32), ethernet-5(33), ethernet-6(34), ethernet-7(35), ethernet-8(36)  

chipRptrMonitorPortGroupIndex 1.3.6.1.4.1.49.2.3.1.5.2.5.2.3.1.1.3
This object identifies the group containing the port for which this entry contains information.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..1024  

chipRptrMonitorPortIndex 1.3.6.1.4.1.49.2.3.1.5.2.5.2.3.1.1.4
This object identifies the port within the group for which this entry contains information.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..1024  

chipRptrMonitorPortReadableFrames 1.3.6.1.4.1.49.2.3.1.5.2.5.2.3.1.1.5
This object is the number of frames of valid frame length that have been received on this port. This counter is incremented by one for each frame received on this port whose OctetCount is greater than or equal to minFrameSize and less than or equal to maxFrameSize (Ref: IEEE 802.3 Std, 4.4.2.1) and for which the FCSError and CollisionEvent signals are not asserted. This statistic provides one of the parameters necessary for obtaining the packet error rate. The approximate minimum time for rollover of this counter is 80 hours.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

chipRptrMonitorPortReadableOctets 1.3.6.1.4.1.49.2.3.1.5.2.5.2.3.1.1.6
This object is the number of octets contained in valid frames that have been received on this port. This counter is incremented by OctetCount for each frame received on this port which has been determined to be a readable frame. This statistic provides an indicator of the total data transferred. The approximate minimum time for rollover of this counter is 58 minutes.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

chipRptrMonitorPortFCSErrors 1.3.6.1.4.1.49.2.3.1.5.2.5.2.3.1.1.7
This counter is incremented by one for each frame received on this port with the FCSError signal asserted and the FramingError and CollisionEvent signals deasserted and whose OctetCount is greater than or equal to minFrameSize and less than or equal to maxFrameSize (Ref: 4.4.2.1, IEEE 802.3 Std). The approximate minimum time for rollover of this counter is 80 hours.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

chipRptrMonitorPortAlignmentErrors 1.3.6.1.4.1.49.2.3.1.5.2.5.2.3.1.1.8
This counter is incremented by one for each frame received on this port with the FCSError and FramingError signals asserted and CollisionEvent signal deasserted and whose OctetCount is greater than or equal to minFrameSize and less than or equal to maxFrameSize (Ref: IEEE 802.3 Std, 4.4.2.1). If chipRptrMonitorPortAlignmentErrors is incremented then the chipRptrMonitorPortFCSErrors Counter shall not be incremented for the same frame. The approximate minimum time for rollover of this counter is 80 hours.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

chipRptrMonitorPortFrameTooLongs 1.3.6.1.4.1.49.2.3.1.5.2.5.2.3.1.1.9
This counter is incremented by one for each frame received on this port whose OctetCount is greater than maxFrameSize (Ref: 4.4.2.1, IEEE 802.3 Std). If chipRptrMonitorPortFrameTooLongs is incremented then neither the chipRptrMonitorPortAlignmentErrors nor the chipRptrMonitorPortFCSErrors counter shall be incremented for the frame. The approximate minimum time for rollover of this counter is 61 days.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

chipRptrMonitorPortShortEvents 1.3.6.1.4.1.49.2.3.1.5.2.5.2.3.1.1.10
This counter is incremented by one for each CarrierEvent on this port with ActivityDuration less than ShortEventMaxTime. ShortEventMaxTime is greater than 74 bit times and less than 82 bit times. ShortEventMaxTime has tolerances included to provide for circuit losses between a conformance test point at the AUI and the measurement point within the state machine. Note: shortEvents may indicate externally generated noise hits which will cause the repeater to transmit Runts to its other ports, or propagate a collision (which may be late) back to the transmitting DTE and damaged frames to the rest of the network. Implementors may wish to consider selecting the ShortEventMaxTime towards the lower end of the allowed tolerance range to accommodate bit losses suffered through physical channel devices not budgeted for within this standard. The approximate minimum time for rollover of this counter is 16 hours.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

chipRptrMonitorPortRunts 1.3.6.1.4.1.49.2.3.1.5.2.5.2.3.1.1.11
This counter is incremented by one for each CarrierEvent on this port that meets one of the following two conditions. Only one test need be made. a) The ActivityDuration is greater than ShortEventMaxTime and less than ValidPacketMinTime and the CollisionEvent signal is deasserted. b) The OctetCount is less than 64, the ActivityDuration is greater than ShortEventMaxTime and the CollisionEvent signal is deasserted. ValidPacketMinTime is greater than or equal to 552 bit times and less than 565 bit times. An event whose length is greater than 74 bit times but less than 82 bit times shall increment either the shortEvents counter or the runts counter but not both. A CarrierEvent greater than or equal to 552 bit times but less than 565 bit times may or may not be counted as a runt. ValidPacketMinTime has tolerances included to provide for circuit losses between a conformance test point at the AUI and the measurement point within the state machine. Runts usually indicate collision fragments, a normal network event. In certain situations associated with large diameter networks a percentage of runts may exceed ValidPacketMinTime. The approximate minimum time for rollover of this counter is 16 hours.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

chipRptrMonitorPortCollisions 1.3.6.1.4.1.49.2.3.1.5.2.5.2.3.1.1.12
This counter is incremented by one for any CarrierEvent signal on any port for which the CollisionEvent signal on this port is asserted. The approximate minimum time for rollover of this counter is 16 hours.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

chipRptrMonitorPortLateEvents 1.3.6.1.4.1.49.2.3.1.5.2.5.2.3.1.1.13
This counter is incremented by one for each CarrierEvent on this port in which the CollIn(X) variable transitions to the value SQE (Ref: 9.6.6.2, IEEE 802.3 Std) while the ActivityDuration is greater than the LateEventThreshold. Such a CarrierEvent is counted twice, as both a collision and as a lateEvent. The LateEventThreshold is greater than 480 bit times and less than 565 bit times. LateEventThreshold has tolerances included to permit an implementation to build a single threshold to serve as both the LateEventThreshold and ValidPacketMinTime threshold. The approximate minimum time for rollover of this counter is 81 hours.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

chipRptrMonitorPortVeryLongEvents 1.3.6.1.4.1.49.2.3.1.5.2.5.2.3.1.1.14
This counter is incremented by one for each CarrierEvent on this port whose ActivityDuration is greater than the MAU Jabber Lockup Protection timer TW3 (Ref: 9.6.1 & 9.6.5, IEEE 802.3 Std). Other counters may be incremented as appropriate.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

chipRptrMonitorPortDataRateMismatches 1.3.6.1.4.1.49.2.3.1.5.2.5.2.3.1.1.15
This counter is incremented by one for each frame received on this port that meets all of the following conditions: a) The CollisionEvent signal is not asserted. b) The ActivityDuration is greater than ValidPacketMinTime. c) The frequency (data rate) is detectably mismatched from the local transmit frequency. The exact degree of mismatch is vendor specific and is to be defined by the vendor for conformance testing. When this event occurs, other counters whose increment conditions were satisfied may or may not also be incremented, at the implementor's discretion. Whether or not the repeater was able to maintain data integrity is beyond the scope of this standard.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

chipRptrMonitorPortAutoPartitions 1.3.6.1.4.1.49.2.3.1.5.2.5.2.3.1.1.16
This counter is incremented by one for each time the repeater has automatically partitioned this port. The conditions that cause port partitioning are specified in the partition state machine in Section 9 [IEEE 802.3 Std]. They are not differentiated here.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

chipRptrMonitorPortTotalErrors 1.3.6.1.4.1.49.2.3.1.5.2.5.2.3.1.1.17
The total number of errors which have occurred on this port. This counter is the summation of the values of other error counters (for the same port), namely: chipRptrMonitorPortFCSErrors, chipRptrMonitorPortAlignmentErrors, chipRptrMonitorPortFrameTooLongs, chipRptrMonitorPortShortEvents, chipRptrMonitorPortLateEvents, chipRptrMonitorPortVeryLongEvents, and chipRptrMonitorPortDataRateMismatches. This counter is redundant in the sense that it is the summation of information already available through other objects. However, it is included specifically because the regular retrieval of this object as a means of tracking the health of a port provides a considerable optimization of network management traffic over the otherwise necessary retrieval of the summed counters.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

chipRptrAddrTrackTable 1.3.6.1.4.1.49.2.3.1.5.2.5.3.3.1
Table of address mapping information about the ports.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ChipRptrAddrTrackEntry

chipRptrAddrTrackEntry 1.3.6.1.4.1.49.2.3.1.5.2.5.3.3.1.1
An entry in the table, containing address mapping information about a single port.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  ChipRptrAddrTrackEntry  

chipRptrAddrTrackSlotIndex 1.3.6.1.4.1.49.2.3.1.5.2.5.3.3.1.1.1
The slot number of the repeater module on which the isolated network identified by chipRptrMonitorGroupNetID resides. If chipRptrMonitorGroupNetID does not identify an isolated network, then the value of this object is backplane(255).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER slot-1(1), slot-2(2), slot-3(3), slot-4(4), slot-5(5), slot-6(6), slot-7(7), slot-8(8), slot-9(9), slot-10(10), slot-11(11), slot-12(12), slot-13(13), slot-14(14), slot-15(15), slot-16(16), slot-17(17), backplane(255)  

chipRptrAddrTrackGroupNetID 1.3.6.1.4.1.49.2.3.1.5.2.5.3.3.1.1.2
The network index that uniquely identifies this port's repeater.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ethernet-1(6), ethernet-2(7), ethernet-3(8), ethernet-4(32), ethernet-5(33), ethernet-6(34), ethernet-7(35), ethernet-8(36)  

chipRptrAddrTrackGroupIndex 1.3.6.1.4.1.49.2.3.1.5.2.5.3.3.1.1.3
This object identifies the group containing the port for which this entry contains information.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..1024  

chipRptrAddrTrackPortIndex 1.3.6.1.4.1.49.2.3.1.5.2.5.3.3.1.1.4
This object identifies the port within the group for which this entry contains information.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..1024  

chipRptrAddrTrackLastSourceAddress 1.3.6.1.4.1.49.2.3.1.5.2.5.3.3.1.1.5
This object is the SourceAddress of the last readable frame (i.e., counted by chipRptrMonitorPortReadableFrames) received by this port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  MacAddress  

chipRptrAddrTrackSourceAddrChanges 1.3.6.1.4.1.49.2.3.1.5.2.5.3.3.1.1.6
This counter is incremented by one for each time that the chipRptrAddrTrackLastSourceAddress attribute for this port has changed. This may indicate whether a link is connected to a single DTE or another multi-user segment. The approximate minimum time for rollover of this counter is 81 hours.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

chipRptrAddrTrackNewLastSrcAddress 1.3.6.1.4.1.49.2.3.1.5.2.5.3.3.1.1.7
This object is the SourceAddress of the last readable frame (i.e., counted by chipRptrMonitorPortReadableFrames) received by this port. If no frames have been received by this port since the agent began monitoring the port activity, the agent shall return a string of length zero.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(0..6)  

olTRnetMapState 1.3.6.1.4.1.49.2.3.1.5.3.1
The state of the inter-module token ring map. If the map is being updated, then the state of the map is changing.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER changing(1), notChanging(2)  

olTRnetStatsTable 1.3.6.1.4.1.49.2.3.1.5.3.2
A list of Token Ring statistics entries counted for each network.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    OlTRnetStatsEntry

olTRnetStatsEntry 1.3.6.1.4.1.49.2.3.1.5.3.2.1
A collection of statistics kept for a particular Token Ring interface.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  OlTRnetStatsEntry  

olTRnetStatsNetID 1.3.6.1.4.1.49.2.3.1.5.3.2.1.1
The network index that uniquely identifies this network. One of token-ring-1 through token-ring-7 or isolated.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER isolated(2), token-ring-1(9), token-ring-2(10), token-ring-3(11), token-ring-4(12), token-ring-5(13), token-ring-6(14), token-ring-7(15)  

olTRnetStatsLineErrors 1.3.6.1.4.1.49.2.3.1.5.3.2.1.2
The total number of line errors reported in error reporting packets detected by the TRMM.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

olTRnetStatsBurstErrors 1.3.6.1.4.1.49.2.3.1.5.3.2.1.3
The total number of burst errors reported in error reporting packets detected by the TRMM.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

olTRnetStatsACErrors 1.3.6.1.4.1.49.2.3.1.5.3.2.1.4
The total number of AC (Address Copied) errors reported in error reporting packets detected by the TRMM.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

olTRnetStatsLostFrameErrors 1.3.6.1.4.1.49.2.3.1.5.3.2.1.5
The total number of lost frame errors reported in error reporting packets detected by the TRMM.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

olTRnetStatsCongestionErrors 1.3.6.1.4.1.49.2.3.1.5.3.2.1.6
The total number of receive congestion errors reported in error reporting packets detected by the TRMM.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

olTRnetStatsFrameCopiedErrors 1.3.6.1.4.1.49.2.3.1.5.3.2.1.7
The total number of frame copied errors reported in error reporting packets detected by the TRMM.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

olTRnetStatsTokenErrors 1.3.6.1.4.1.49.2.3.1.5.3.2.1.8
The total number of token errors reported in error reporting packets detected by the TRMM.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

olTRnetStatsDuplicateAddresses 1.3.6.1.4.1.49.2.3.1.5.3.2.1.9
The total number of token errors reported in error reporting packets detected by the TRMM.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

olTRnetStatsBeaconEvents 1.3.6.1.4.1.49.2.3.1.5.3.2.1.10
The total number of times that the ring enters the beaconing state.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

olTRnetStatsLastBeaconSender 1.3.6.1.4.1.49.2.3.1.5.3.2.1.11
The address of the sender of the last beacon frame received on this ring. If no beacon frames have been received, this object will be six zero octets.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(6)  

olTRnetStatsLastBeaconNAUN 1.3.6.1.4.1.49.2.3.1.5.3.2.1.12
The address of the NAUN in the last beacon frame received on this ring. If no beacon frames have been received, this object will be six zero octets.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(6)  

olTRnetStatsLastBeaconTime 1.3.6.1.4.1.49.2.3.1.5.3.2.1.13
The time in in hundredths of a second since the last beacon event occurred. For example, if the time is 500 ticks, then this event was seen 5 seconds ago. If no beacon events have occurred, then this will be equal to the sysUpTime.
Status: mandatory Access: read-only
OBJECT-TYPE    
  TimeTicks  

olTRnetStatsLastBeaconAction 1.3.6.1.4.1.49.2.3.1.5.3.2.1.14
The action (if any) taken to correct the last beacon event on the ring.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noAction(1), portDisable(2), trunkDisable(3), moduleIsolate(4)  

olTRnetStatsTotalStations 1.3.6.1.4.1.49.2.3.1.5.3.2.1.15
The number of stations currently participating in the 802.5 MAC protocol on the ring.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..255  

olTRnetStatsConcStations 1.3.6.1.4.1.49.2.3.1.5.3.2.1.16
The number of stations currently participating in the 802.5 MAC protocol on the ring which are connected to ports in this concentrator.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..255  

olTRnetStatsTotalPorts 1.3.6.1.4.1.49.2.3.1.5.3.2.1.17
The total number of ports within this concentrator and on this ring regardless of their admin state or status.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

olTRnetStatsEnabledPorts 1.3.6.1.4.1.49.2.3.1.5.3.2.1.18
The number of ports within this concentrator and on this ring which have olPortAdminState set to enabled.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

olTRnetStatsActivePorts 1.3.6.1.4.1.49.2.3.1.5.3.2.1.19
The number of ports within this concentrator and on this ring which have olPortAdminState set to enabled and whose olPortStatus has a status of okay.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

olTRnetStatsStationTable 1.3.6.1.4.1.49.2.3.1.5.3.3
A list of ring statistics entries.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    OlTRnetStatsStationEntry

olTRnetStatsStationEntry 1.3.6.1.4.1.49.2.3.1.5.3.3.1
A collection of statistics for a particular station that has been discovered on a a ring monitored by this device.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  OlTRnetStatsStationEntry  

olTRnetStatsStationNetID 1.3.6.1.4.1.49.2.3.1.5.3.3.1.1
The network index that uniquely identifies this network. One of token-ring-1 through token-ring-7 or isolated.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER isolated(2), token-ring-1(9), token-ring-2(10), token-ring-3(11), token-ring-4(12), token-ring-5(13), token-ring-6(14), token-ring-7(15)  

olTRnetStatsStationAddr 1.3.6.1.4.1.49.2.3.1.5.3.3.1.2
The physical address of this station.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(6)  

olTRnetStatsStationSlotIndex 1.3.6.1.4.1.49.2.3.1.5.3.3.1.3
The slot number of the station with this address. Addresses with a slot value of external(255) are not in this concentrator.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER slot-1(1), slot-2(2), slot-3(3), slot-4(4), slot-5(5), slot-6(6), slot-7(7), slot-8(8), slot-9(9), slot-10(10), slot-11(11), slot-12(12), slot-13(13), slot-14(14), slot-15(15), slot-16(16), slot-17(17), external(255)  

olTRnetStatsStationPortIndex 1.3.6.1.4.1.49.2.3.1.5.3.3.1.4
The port number within olTRnetStatsStationSlotIndex's slot that received this address. If olTRnetStatsStationSlotIndex has a value of external(255), then the port address will be 255.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

olTRnetStatsStationNAUNAddress 1.3.6.1.4.1.49.2.3.1.5.3.3.1.5
The physical address of the nearest active upstream neighbor of this station.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(6)  

olTRnetStatsStationLineErrors 1.3.6.1.4.1.49.2.3.1.5.3.3.1.6
The total number of Line Errors pertaining to this station reported in error reporting packets detected by the TRMM.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

olTRnetStatsStationBurstErrors 1.3.6.1.4.1.49.2.3.1.5.3.3.1.7
The total number of burst errors pertaining to this station reported in error reporting packets detected by the TRMM.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

olTRnetStatsStationACErrors 1.3.6.1.4.1.49.2.3.1.5.3.3.1.8
The total number of AC (Address Copied) errors pertaining to this station reported in error reporting packets detected by the TRMM.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

olTRnetStatsStationLostFrameErrors 1.3.6.1.4.1.49.2.3.1.5.3.3.1.9
The total number of lost frame errors pertaining to this station reported in error reporting packets detected by the TRMM.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

olTRnetStatsStationCongestionErrors 1.3.6.1.4.1.49.2.3.1.5.3.3.1.10
The total number of congestion errors pertaining to this station reported in error reporting packets detected by the TRMM.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

olTRnetStatsStationFrameCopiedErrors 1.3.6.1.4.1.49.2.3.1.5.3.3.1.11
The total number of frame copied errors pertaining to this station reported in error reporting packets detected by the TRMM.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

olTRnetStatsStationTokenErrors 1.3.6.1.4.1.49.2.3.1.5.3.3.1.12
The total number of token errors pertaining to this station reported in error reporting packets detected by the TRMM.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

olTRnetStatsStationDuplicateAddresses 1.3.6.1.4.1.49.2.3.1.5.3.3.1.13
The number of times this station experienced a duplicate address error.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

olTRnetStatsPortTable 1.3.6.1.4.1.49.2.3.1.5.3.4
A list of statistic entries, for ports within the concentrator.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    OlTRnetStatsPortEntry

olTRnetStatsPortEntry 1.3.6.1.4.1.49.2.3.1.5.3.4.1
A collection of statistics for a particular station that has been discovered on a a ring monitored by this device.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  OlTRnetStatsPortEntry  

olTRnetStatsPortSlotIndex 1.3.6.1.4.1.49.2.3.1.5.3.4.1.1
The port slot number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

olTRnetStatsPortIndex 1.3.6.1.4.1.49.2.3.1.5.3.4.1.2
The port number within olTRnetStatsPortSlotIndex's slot.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

olTRnetStatsPortNetID 1.3.6.1.4.1.49.2.3.1.5.3.4.1.3
The network index that uniquely identifies this network. One of token-ring-1 through token-ring-7 or isolated.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER isolated(2), token-ring-1(9), token-ring-2(10), token-ring-3(11), token-ring-4(12), token-ring-5(13), token-ring-6(14), token-ring-7(15)  

olTRnetStatsPortTotalStations 1.3.6.1.4.1.49.2.3.1.5.3.4.1.4
The total number of stations attached to this port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

olTRnetStatsPortAddress 1.3.6.1.4.1.49.2.3.1.5.3.4.1.5
The mac address of the station connected to this If there are multiple mac addresses for this port, then this object will contain the last mac address.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(6)  

olTRnetStatsPortLineErrors 1.3.6.1.4.1.49.2.3.1.5.3.4.1.6
The total number of Line Errors pertaining to this port reported in error reporting packets detected by the TRMM.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

olTRnetStatsPortBurstErrors 1.3.6.1.4.1.49.2.3.1.5.3.4.1.7
The total number of burst errors pertaining to this port reported in error reporting packets detected by the TRMM.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

olTRnetStatsPortACErrors 1.3.6.1.4.1.49.2.3.1.5.3.4.1.8
The total number of AC (Address Copied) errors pertaining to this port reported in error reporting packets detected by the TRMM.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

olTRnetStatsPortLostFrameErrors 1.3.6.1.4.1.49.2.3.1.5.3.4.1.9
The total number of lost frame errors pertaining to this port reported in error reporting packets detected by the TRMM.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

olTRnetStatsPortCongestionErrors 1.3.6.1.4.1.49.2.3.1.5.3.4.1.10
The total number of congestion errors pertaining to this port reported in error reporting packets detected by the TRMM.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

olTRnetStatsPortFrameCopiedErrors 1.3.6.1.4.1.49.2.3.1.5.3.4.1.11
The total number of frame copied errors pertaining to this port reported in error reporting packets detected by the TRMM.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

olTRnetStatsPortTokenErrors 1.3.6.1.4.1.49.2.3.1.5.3.4.1.12
The total number of token errors pertaining to this station reported in error reporting packets detected by the TRMM.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

olTRnetStatsPortDuplicateAddresses 1.3.6.1.4.1.49.2.3.1.5.3.4.1.13
The number of times this port experienced a duplicate address error.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

olTRnetMapSummary 1.3.6.1.4.1.49.2.3.1.5.3.5
OBJECT IDENTIFIER    

olTRnetMapSummaryLogicalState 1.3.6.1.4.1.49.2.3.1.5.3.5.1
The state of the token ring summary table. If the summary is being updated, then the state of the summary is changing.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER changing(1), notChanging(2)  

olTRnetMapSummaryLogicalLock 1.3.6.1.4.1.49.2.3.1.5.3.5.2
A semaphore for locking the token ring summary table. When locked, updates to the summary will pend until the semaphore is unlocked, so that a valid summary can be read. This cannot be set to unlock if olTRnetSummaryLogicalState is changing. For complete accuracy, this should be read after being set to ensure that the map was not changing when the lock was attempted. After the summary information has been recorded, the semaphore should be set to unlock to allow changes to occur.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER lock(1), unlock(2)  

olTRnetMapSummaryTable 1.3.6.1.4.1.49.2.3.1.5.3.5.3
A logical map of the token ring network, starting from the agent's specified token ring interface. Each station on the map is represented by it's MAC address, slot number and port number (8 octets per station). If the port is external to the concentrator, the slot number and the port number will be 255. The map is ordered in the same direction as the token flow. The MAC addresses are concatonated into groups of up to 32 addresses per entry. This table supports up to 256 stations.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    OlTRnetMapSummaryEntry

olTRnetMapSummaryEntry 1.3.6.1.4.1.49.2.3.1.5.3.5.3.1
A group of MAC addresses associated with a Token Ring map.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  OlTRnetMapSummaryEntry  

olTRnetMapSummaryNetID 1.3.6.1.4.1.49.2.3.1.5.3.5.3.1.1
The network index that uniquely identifies this network. It can be isolated from the backplane, or on one of seven possible backplane token ring networks.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER isolated(2), token-ring-1(9), token-ring-2(10), token-ring-3(11), token-ring-4(12), token-ring-5(13), token-ring-6(14), token-ring-7(15)  

olTRnetMapSummaryIndex 1.3.6.1.4.1.49.2.3.1.5.3.5.3.1.2
The index into the map array. Possible values are 1 through 8. The MAC address of this agent is the first MAC address in olTRnetMapSummary32Stations indexed by a 1 in this entry.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

olTRnetMapSummary32Stations 1.3.6.1.4.1.49.2.3.1.5.3.5.3.1.3
A concatonated group of MAC addresses and their associated slot and port of stations on the ring. Each entry has the eight octets. The first six octets are the MAC address. The seventh octet is the slot ID (or 255 if it is external to the concentrator). The eighth is the port ID (or 255 if it is external to the concentrator). The MAC addresses are in the same order as the token flow.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(8..256)  

olTRTrafTable 1.3.6.1.4.1.49.2.3.1.5.3.6
A list of Token Ring network traffic (non-error) statistics entries. Note that all of the frame and octet counters in this table include error frames that have valid length; all octet counters exclude framing bits but include FCS octets.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    OlTRTrafEntry

olTRTrafEntry 1.3.6.1.4.1.49.2.3.1.5.3.6.1
A collection of statistics kept for a particular Token Ring interface. Note that all of the frame and octet counters in this table include error frames that have valid length; all octet counters exclude framing bits but include FCS octets.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  OlTRTrafEntry  

olTRTrafNetID 1.3.6.1.4.1.49.2.3.1.5.3.6.1.1
The network index that uniquely identifies this network. One of token-ring-1 through token-ring-7 or isolated.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER isolated(2), token-ring-1(9), token-ring-2(10), token-ring-3(11), token-ring-4(12), token-ring-5(13), token-ring-6(14), token-ring-7(15)  

olTRTrafTokenRotationTime 1.3.6.1.4.1.49.2.3.1.5.3.6.1.2
An estimate of the time (in microseconds) that it takes for the token to complete a single rotation around the ring.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

olTRTrafDropEvents 1.3.6.1.4.1.49.2.3.1.5.3.6.1.3
The total number of events in which frames were dropped by the TRMM due to lack of resources. Note that this number is not necessarily the number of frames dropped; it is just the number of times this condition has been detected.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

olTRTrafOctets 1.3.6.1.4.1.49.2.3.1.5.3.6.1.4
The total number of octets of data received on the network.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

olTRTrafFrames 1.3.6.1.4.1.49.2.3.1.5.3.6.1.5
The total number of frames received.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

olTRTrafMacOctets 1.3.6.1.4.1.49.2.3.1.5.3.6.1.6
The total number of octets of data in MAC frames received on the network.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

olTRTrafMacFrames 1.3.6.1.4.1.49.2.3.1.5.3.6.1.7
The total number of MAC frames received.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

olTRTrafBroadcastFrames 1.3.6.1.4.1.49.2.3.1.5.3.6.1.8
The total number of non-MAC frames received that were directed to a broadcast address (0xFFFFFFFFFFFF or 0xC000FFFFFFFF).
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

olTRTrafMulticastFrames 1.3.6.1.4.1.49.2.3.1.5.3.6.1.9
The total number of non-MAC frames received that were directed to a local or global multicast or functional address. Note that this number does not include frames directed to a broadcast address.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

olTRTrafFrames18to63Octets 1.3.6.1.4.1.49.2.3.1.5.3.6.1.10
The total number of non-MAC frames received that were between 18 and 63 octets in length inclusive.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

olTRTrafFrames64to127Octets 1.3.6.1.4.1.49.2.3.1.5.3.6.1.11
The total number of non-MAC frames received that were between 64 and 127 octets in length inclusive.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

olTRTrafFrames128to255Octets 1.3.6.1.4.1.49.2.3.1.5.3.6.1.12
The total number of non-MAC frames received that were between 128 and 255 octets in length inclusive.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

olTRTrafFrames256to511Octets 1.3.6.1.4.1.49.2.3.1.5.3.6.1.13
The total number of non-MAC frames received that were between 256 and 511 octets in length inclusive.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

olTRTrafFrames512to1023Octets 1.3.6.1.4.1.49.2.3.1.5.3.6.1.14
The total number of non-MAC frames received that were between 512 and 1023 octets in length inclusive.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

olTRTrafFrames1024to2047Octets 1.3.6.1.4.1.49.2.3.1.5.3.6.1.15
The total number of non-MAC frames received that were between 1024 and 2047 octets in length inclusive.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

olTRTrafFrames2048to4095Octets 1.3.6.1.4.1.49.2.3.1.5.3.6.1.16
The total number of non-MAC frames received that were between 2048 and 4095 octets in length inclusive.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

olTRTrafFrames4096to8191Octets 1.3.6.1.4.1.49.2.3.1.5.3.6.1.17
The total number of non-MAC frames received that were between 4096 and 8191 octets in length inclusive.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

olTRTrafFrames8192to18000Octets 1.3.6.1.4.1.49.2.3.1.5.3.6.1.18
The total number of non-MAC frames received that were between 8192 and 18000 octets in length inclusive.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

olTRTrafFramesGreaterThan18000Octets 1.3.6.1.4.1.49.2.3.1.5.3.6.1.19
The total number of non-MAC frames received that were greater than or equal to 18000 octets in length.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

olTRTrafControlTable 1.3.6.1.4.1.49.2.3.1.5.3.7
A list entries containing information about olTRTrafStationTable, olTRTrafPortTable, olTRTrafTopNTable, and olTRTrafTopNSummaryTable
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    OlTRTrafControlEntry

olTRTrafControlEntry 1.3.6.1.4.1.49.2.3.1.5.3.7.1
A collection of information about olTRTrafStationTable, olTRTrafPortTable, olTRTrafTopNTable, and olTRTrafTopNSummaryTable
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  OlTRTrafControlEntry  

olTRTrafControlNetID 1.3.6.1.4.1.49.2.3.1.5.3.7.1.1
The network index that uniquely identifies this network. One of token-ring-1 through token-ring-7 or isolated.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER isolated(2), token-ring-1(9), token-ring-2(10), token-ring-3(11), token-ring-4(12), token-ring-5(13), token-ring-6(14), token-ring-7(15)  

olTRTrafControlLogicalState 1.3.6.1.4.1.49.2.3.1.5.3.7.1.2
The state of the token ring station traffic tables: olTRTrafStationTable, olTRTrafPortTable, olTRTrafTopNTable and olTRTrafTopNSummaryTable. If any of the tables associated with this olTRTrafControlEntry are being updated, then the state is changing(1).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER changing(1), notChanging(2)  

olTRTrafControlLogicalLock 1.3.6.1.4.1.49.2.3.1.5.3.7.1.3
A semaphore for locking the token ring station traffic tables: olTRTrafStationTable, olTRTrafPortTable, olTRTrafTopNTable, and olTRTrafTopNSummaryTable. When the semaphore is locked, adds, deletes, and re-sorting the traffic tables associated with this olTRTrafControlEntry will pend until the semaphore is unlocked, so that a valid set of entries can be read. Note that the normal incrementing of the traffic counters are not affected by the setting of this semaphore. This cannot be set to unlock if olTRTrafControlLogicalState is changing. For complete accuracy, this semaphore should be read after being set to ensure that the tables were not changing when the lock was attempted. After the table information has been recorded, the semaphore should be set to unlock to allow changes to occur.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER lock(1), unlock(2)  

olTRTrafControlClear 1.3.6.1.4.1.49.2.3.1.5.3.7.1.4
When the value of this object is set to clear, all entries in the token ring station traffic tables (olTRTrafStationTable, olTRTrafPortTable, olTRTrafTopNTable, and olTRTrafTopNSummaryTable) are cleared.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER normal(1), clear(2)  

olTRTrafControlLastClearTime 1.3.6.1.4.1.49.2.3.1.5.3.7.1.5
The value of sysUpTime when the token ring station traffic tables (olTRTrafStationTable, olTRTrafPortTable, olTRTrafTopNTable and olTRTrafTopNSummaryTable) were cleared. If never cleared, this value shall be zero (and the token ring station traffic tables will contain information collected since startup).
Status: mandatory Access: read-only
OBJECT-TYPE    
  TimeTicks  

olTRTrafControlTotalStations 1.3.6.1.4.1.49.2.3.1.5.3.7.1.6
The number of stations in the portion of the olTRTrafStationTable associated with this olTRTrafControlEntry.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

olTRTrafControlStationLastChangeTime 1.3.6.1.4.1.49.2.3.1.5.3.7.1.7
The value of sysUpTime when the last entry was added to or deleted (or re-sorted) from the portion of the olTRTrafStationTable associated with this olTRTrafControlEntry. If no additions or deletions have occurred, this value shall be zero.
Status: mandatory Access: read-only
OBJECT-TYPE    
  TimeTicks  

olTRTrafControlPortTotalStations 1.3.6.1.4.1.49.2.3.1.5.3.7.1.8
The number of stations in the portion of the olTRTrafPortTable associated with this olTRTrafControlEntry.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

olTRTrafControlPortLastChangeTime 1.3.6.1.4.1.49.2.3.1.5.3.7.1.9
The value of sysUpTime when the last entry was added to or deleted (or re-sorted) from the portion of the olTRTrafPortTable associated with this olTRTrafControlEntry. If no additions or deletions have occurred, this value shall be zero.
Status: mandatory Access: read-only
OBJECT-TYPE    
  TimeTicks  

olTRTrafControlTopNMaxStations 1.3.6.1.4.1.49.2.3.1.5.3.7.1.10
Specifies a maximum value for olTRTrafControlTopNTotalStations in this olTRTrafControlEntry. If this value is zero then no maximum value for olTRTrafControlTopNTotalStations is specified.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

olTRTrafControlTopNTotalStations 1.3.6.1.4.1.49.2.3.1.5.3.7.1.11
The number of stations (for each statistic) in the portion of the olTRTrafTopNTable and olTRTrafTopNSummaryTable associated with this olTRTrafControlEntry. If olTRTrafControlTopNMaxStations is zero or is not less than olTRTrafControlTotalStations then olTRTrafControlTopNTotalStations will have the same value as olTRTrafControlTotalStations. Otherwise olTRTrafControlTopNTotalStations will have the same value as olTRTrafControlTopNMaxStations.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

olTRTrafControlTopNLastChangeTime 1.3.6.1.4.1.49.2.3.1.5.3.7.1.12
The value of sysUpTime when the last entry was added to or deleted (or re-sorted) from the portion of the olTRTrafTopNTable and olTRTrafTopNSummaryTable associated with this olTRTrafControlEntry. This is equivalent to the time when the last TopN data collection period ended. If no additions or deletions have occurred, this value shall be zero.
Status: mandatory Access: read-only
OBJECT-TYPE    
  TimeTicks  

olTRTrafControlTopNInterval 1.3.6.1.4.1.49.2.3.1.5.3.7.1.13
Specifies the length of the TopN data collection period in seconds. Minimum length is 5 seconds; maximum is 86400 seconds (24 hours). When this value is modified, all associated entries in olTRTrafTopNTable and olTRTrafTopNSummaryTable are deleted and a new TopN data collection period is started.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

olTRTrafStationTable 1.3.6.1.4.1.49.2.3.1.5.3.8
A list of Token Ring station traffic statistics entries indexed by Network ID and MAC address. The table has olTRTrafTotalStations entries. Note that all of the frame and octet counters in this table include error frames that have valid length; all octet counters exclude framing bits but include FCS octets.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    OlTRTrafStationEntry

olTRTrafStationEntry 1.3.6.1.4.1.49.2.3.1.5.3.8.1
A collection of station statistics for a particular station that has been discovered on an interface of this device. Note that all of the frame and octet counters in this table include error frames that have valid length; all octet counters exclude framing bits but include FCS octets.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  OlTRTrafStationEntry  

olTRTrafStationNetID 1.3.6.1.4.1.49.2.3.1.5.3.8.1.1
The network index that uniquely identifies this network. One of token-ring-1 through token-ring-7 or isolated.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER isolated(2), token-ring-1(9), token-ring-2(10), token-ring-3(11), token-ring-4(12), token-ring-5(13), token-ring-6(14), token-ring-7(15)  

olTRTrafStationAddress 1.3.6.1.4.1.49.2.3.1.5.3.8.1.2
The physical address of this station.
Status: mandatory Access: read-only
OBJECT-TYPE    
  MacAddress  

olTRTrafStationSlotIndex 1.3.6.1.4.1.49.2.3.1.5.3.8.1.3
The slot number of the station with this address. Addresses with a slot value of remote-ring(254) are not in this ring. Addresses with a slot value of external(255) are not in this concentrator.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER slot-1(1), slot-2(2), slot-3(3), slot-4(4), slot-5(5), slot-6(6), slot-7(7), slot-8(8), slot-9(9), slot-10(10), slot-11(11), slot-12(12), slot-13(13), slot-14(14), slot-15(15), slot-16(16), slot-17(17), remote-ring(254), external(255)  

olTRTrafStationPortIndex 1.3.6.1.4.1.49.2.3.1.5.3.8.1.4
The port number within olTRTrafSlotIndex's slot that received this address. If olTRTrafSlotIndex has a value of remote-ring(254), then the port address will be 254. If olTRTrafSlotIndex has a value of external(255), then the port address will be 255.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

olTRTrafStationInFrames 1.3.6.1.4.1.49.2.3.1.5.3.8.1.5
The number of frames transmitted to this address since it was added to this table.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

olTRTrafStationOutFrames 1.3.6.1.4.1.49.2.3.1.5.3.8.1.6
The number of frames transmitted by this address since it was added to this table.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

olTRTrafStationInOctets 1.3.6.1.4.1.49.2.3.1.5.3.8.1.7
The number of octets transmitted to this address since it was added to this table.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

olTRTrafStationOutOctets 1.3.6.1.4.1.49.2.3.1.5.3.8.1.8
The number of octets transmitted by this address since it was added to this table.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

olTRTrafStationOutErrors 1.3.6.1.4.1.49.2.3.1.5.3.8.1.9
The number of error frames transmitted by this address since it was added to this table. Only isolating errors (LineErrors, BurstErrors, ACErrors, InternalErrors, and AbortErrors) and CongestionErrors are counted.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

olTRTrafStationOutBroadcastFrames 1.3.6.1.4.1.49.2.3.1.5.3.8.1.10
The number of frames transmitted by this address that were directed to the broadcast address since it was added to this table.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

olTRTrafStationOutMulticastFrames 1.3.6.1.4.1.49.2.3.1.5.3.8.1.11
The number of frames transmitted by this address that were directed to a multicast address since it was added to this table. Note that this number does not include frames directed to the broadcast address.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

olTRTrafPortTable 1.3.6.1.4.1.49.2.3.1.5.3.9
A list of Token Ring station traffic statistics entries indexed by slot number, and port number. Note that stations external to this concentrator or on another ring are excluded from this table. Note that all of the frame and octet counters in this table include error frames that have valid length; all octet counters exclude framing bits but include FCS octets.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    OlTRTrafPortEntry

olTRTrafPortEntry 1.3.6.1.4.1.49.2.3.1.5.3.9.1
A collection of station statistics for a particular station that has been discovered on an interface of this device. Note that all of the frame and octet counters in this table include error frames that have valid length; all octet counters exclude framing bits but include FCS octets. include error frames; all octet counters exclude framing bits but include FCS octets.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  OlTRTrafPortEntry  

olTRTrafPortSlotIndex 1.3.6.1.4.1.49.2.3.1.5.3.9.1.1
The slot number of the station with this address.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

olTRTrafPortPortIndex 1.3.6.1.4.1.49.2.3.1.5.3.9.1.2
The port number within olTRTrafPortSlotIndex's slot that received this address.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

olTRTrafPortNetID 1.3.6.1.4.1.49.2.3.1.5.3.9.1.3
The network index that uniquely identifies this network. One of token-ring-1 through token-ring-7 or isolated.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER isolated(2), token-ring-1(9), token-ring-2(10), token-ring-3(11), token-ring-4(12), token-ring-5(13), token-ring-6(14), token-ring-7(15)  

olTRTrafPortAddress 1.3.6.1.4.1.49.2.3.1.5.3.9.1.4
The physical address of this station.
Status: mandatory Access: read-only
OBJECT-TYPE    
  MacAddress  

olTRTrafPortInFrames 1.3.6.1.4.1.49.2.3.1.5.3.9.1.5
The number of frames transmitted to this address since it was added to this table.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

olTRTrafPortOutFrames 1.3.6.1.4.1.49.2.3.1.5.3.9.1.6
The number of frames transmitted by this address since it was added to this table.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

olTRTrafPortInOctets 1.3.6.1.4.1.49.2.3.1.5.3.9.1.7
The number of octets transmitted to this address since it was added to this table.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

olTRTrafPortOutOctets 1.3.6.1.4.1.49.2.3.1.5.3.9.1.8
The number of octets transmitted by this address since it was added to this table.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

olTRTrafPortOutErrors 1.3.6.1.4.1.49.2.3.1.5.3.9.1.9
The number of error frames transmitted by this address since it was added to this table. Only isolating errors (LineErrors, BurstErrors, ACErrors, InternalErrors, and AbortErrors) and CongestionErrors are counted.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

olTRTrafPortOutBroadcastFrames 1.3.6.1.4.1.49.2.3.1.5.3.9.1.10
The number of frames transmitted by this address that were directed to the broadcast address since it was added to this table.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

olTRTrafPortOutMulticastFrames 1.3.6.1.4.1.49.2.3.1.5.3.9.1.11
The number of frames transmitted by this address that were directed to a multicast address since it was added to this table. Note that this number does not include frames directed to the broadcast address.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

olTRTrafTopNTable 1.3.6.1.4.1.49.2.3.1.5.3.10
A list of Token Ring station traffic statistics entries indexed by olTRTrafTopNNetID, olTRTrafTopNStatistic, and olTRTrafTopNIndex. For each Network, the list contains 7 logical sublists - one for each statistic. Each of the sublists has olTRTrafControlTopNTotalStations entries. For eack Network, the table has 7 times olTRTrafTopNControlTotalStations entries. All of the counters in this table reflect activity during the last completed TopN data collection period (olTRTrafControlTopNInterval seconds). Note that this table will contain no entries if a TopN data collection period has not yet completed since olTRTrafControlTopNInterval was modified or since startup. Note that all of the frame and octet counters in this table include error frames that have valid length; all octet counters exclude framing bits but include FCS octets.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    OlTRTrafTopNEntry

olTRTrafTopNEntry 1.3.6.1.4.1.49.2.3.1.5.3.10.1
A collection of station statistics for a particular station that has been discovered on an interface of this device. Note that all of the frame and octet counters in this table include error frames that have valid length; all octet counters exclude framing bits but include FCS octets.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  OlTRTrafTopNEntry  

olTRTrafTopNNetID 1.3.6.1.4.1.49.2.3.1.5.3.10.1.1
The network index that uniquely identifies this network. One of token-ring-1 through token-ring-7 or isolated.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER isolated(2), token-ring-1(9), token-ring-2(10), token-ring-3(11), token-ring-4(12), token-ring-5(13), token-ring-6(14), token-ring-7(15)  

olTRTrafTopNStatistic 1.3.6.1.4.1.49.2.3.1.5.3.10.1.2
The object representing the statistic for each station that this portion of the olTRTrafTopNTable is sorted on.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER olTRTrafTopNInFrames(1), olTRTrafTopNOutFrames(2), olTRTrafTopNInOctets(3), olTRTrafTopNOutOctets(4), olTRTrafTopNOutErrors(5), olTRTrafTopNOutBroadcastFrames(6), olTRTrafTopNOutMulticastFrames(7)  

olTRTrafTopNIndex 1.3.6.1.4.1.49.2.3.1.5.3.10.1.3
An index that uniquely identifies an entry in the olTRTrafTopN table among those in the same network and for the same olTRTrafTopNStatistic. This index is between 1 and N, where N is the value of olTRTrafControlTopNTotalStations. Increasing values of olTRTrafTopNIndex shall be assigned to entries with decreasing values of the object referenced by olTRTrafTopNStatistic.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

olTRTrafTopNAddress 1.3.6.1.4.1.49.2.3.1.5.3.10.1.4
The physical address of this station.
Status: mandatory Access: read-only
OBJECT-TYPE    
  MacAddress  

olTRTrafTopNSlotIndex 1.3.6.1.4.1.49.2.3.1.5.3.10.1.5
The slot number of the station with this address. Addresses with a slot value of remote-ring(254) are not in this ring. Addresses with a slot value of external(255) are not in this concentrator.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER slot-1(1), slot-2(2), slot-3(3), slot-4(4), slot-5(5), slot-6(6), slot-7(7), slot-8(8), slot-9(9), slot-10(10), slot-11(11), slot-12(12), slot-13(13), slot-14(14), slot-15(15), slot-16(16), slot-17(17), remote-ring(254), external(255)  

olTRTrafTopNPortIndex 1.3.6.1.4.1.49.2.3.1.5.3.10.1.6
The port number within olTRTrafTopNSlotIndex's slot that received this address. If olTRTrafTopNSlotIndex has a value of remote-ring(254), then the port address will be 254. If olTRTrafTopNSlotIndex has a value of external(255), then the port address will be 255.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

olTRTrafTopNInFrames 1.3.6.1.4.1.49.2.3.1.5.3.10.1.7
The number of frames transmitted to this address during the last TopN data collection period.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

olTRTrafTopNOutFrames 1.3.6.1.4.1.49.2.3.1.5.3.10.1.8
The number of frames transmitted by this address during the last TopN data collection period.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

olTRTrafTopNInOctets 1.3.6.1.4.1.49.2.3.1.5.3.10.1.9
The number of octets transmitted to this address during the last TopN data collection period.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

olTRTrafTopNOutOctets 1.3.6.1.4.1.49.2.3.1.5.3.10.1.10
The number of octets transmitted by this address during the last TopN data collection period.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

olTRTrafTopNOutErrors 1.3.6.1.4.1.49.2.3.1.5.3.10.1.11
The number of error frames transmitted by this address during the last TopN data collection period. Only isolating errors (LineErrors, BurstErrors, ACErrors, InternalErrors, and AbortErrors) and CongestionErrors are counted.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

olTRTrafTopNOutBroadcastFrames 1.3.6.1.4.1.49.2.3.1.5.3.10.1.12
The number of frames transmitted by this address that were directed to the broadcast address during the last TopN data collection period.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

olTRTrafTopNOutMulticastFrames 1.3.6.1.4.1.49.2.3.1.5.3.10.1.13
The number of frames transmitted by this address that were directed to a multicast address during the last TopN data collection period. Note that this number does not include frames directed to the broadcast address.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

olTRTrafTopNSummaryTable 1.3.6.1.4.1.49.2.3.1.5.3.11
A list containing information from olTRTrafTopNTable provided for the convenience of network management stations that wish to obtain this information in condensed form.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    OlTRTrafTopNSummaryEntry

olTRTrafTopNSummaryEntry 1.3.6.1.4.1.49.2.3.1.5.3.11.1
A segment of the Top N list for a particular statistic.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  OlTRTrafTopNSummaryEntry  

olTRTrafTopNSummaryNetID 1.3.6.1.4.1.49.2.3.1.5.3.11.1.1
The network index that uniquely identifies this network. One of token-ring-1 through token-ring-7 or isolated.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER isolated(2), token-ring-1(9), token-ring-2(10), token-ring-3(11), token-ring-4(12), token-ring-5(13), token-ring-6(14), token-ring-7(15)  

olTRTrafTopNSummaryStatistic 1.3.6.1.4.1.49.2.3.1.5.3.11.1.2
The object representing the statistic for each station that this portion of the olTRTrafTopNSummaryTable is sorted on.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER olTRTrafTopNSummaryInFrames(1), olTRTrafTopNSummaryOutFrames(2), olTRTrafTopNSummaryInOctets(3), olTRTrafTopNSummaryOutOctets(4), olTRTrafTopNSummaryOutErrors(5), olTRTrafTopNSummaryOutBroadcastFrames(6), olTRTrafTopNSummaryOutMulticastFrames(7)  

olTRTrafTopNSummaryIndex 1.3.6.1.4.1.49.2.3.1.5.3.11.1.3
An index that uniquely identifies an entry in the olTRTrafTopNSummary table among those in the same network and for the same olTRTrafTopNSummaryStatistic. The number of entries for this portion of olTRTrafTopNSummaryTable is number of entries for the corresponding portion of olTRTrafTopNTable divided by 12 (rounded up to the next integer).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

olTRTrafTopNSummaryStations 1.3.6.1.4.1.49.2.3.1.5.3.11.1.4
A concatonated list of (up to 12) MAC addresses, their associated slot and port, and a statistic value for traffic associated with stations on the ring. Each entry has 36 octets. The first 6 octets are the MAC address. The 7th octet is the slot ID (or 255 if it is external to the concentrator or 254 if it is on a remote ring). The 8th is the port ID (or 255 if it is external to the concentrator or 254 if it is on a remote ring). The 9th through 36th octets contain the values of the statistics olTRTrafTopNInFrames, olTRTrafTopNOutFrames, olTRTrafTopNInOctets, olTRTrafTopNOutOctets, olTRTrafTopNOutErrors, olTRTrafTopNOutBroadcastFrames, and olTRTrafTopNOutMulticastFrames. Each statistic is represented in 4 octets, most significant octet first. The stations are in order of decreasing values of the statistic referenced by olTRTrafTopNStatistic.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

olFDDIStatsModTable 1.3.6.1.4.1.49.2.3.1.5.4.2
A table of statistical information counted for each module in each FDDI network.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    OlFDDIStatsModEntry

olFDDIStatsModEntry 1.3.6.1.4.1.49.2.3.1.5.4.2.1
A list of statistical information for each module on each FDDI network in the concentrator.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  OlFDDIStatsModEntry  

olFDDIStatsModSlotIndex 1.3.6.1.4.1.49.2.3.1.5.4.2.1.1
The slot number that contains this module.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

olFDDIStatsModMgtRcvErrs 1.3.6.1.4.1.49.2.3.1.5.4.2.1.2
The number of errors encountered while receiving data on the Management Channel.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

olFDDIStatsModMgtXmitErrs 1.3.6.1.4.1.49.2.3.1.5.4.2.1.3
The number of errors encountered while transmitting data on the Management Channel.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

olFDDIStatsModBackplaneErrs 1.3.6.1.4.1.49.2.3.1.5.4.2.1.4
The number of errors while receiving and transmitting network data on the backplane.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

olFDDIStatsModPllUnlockErrs 1.3.6.1.4.1.49.2.3.1.5.4.2.1.5
The number of times the phased lock loop on the backplane network data channel was lost.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

olFDDIStatsPortTable 1.3.6.1.4.1.49.2.3.1.5.4.3
A table of statistical information counted for each Port in each FDDI network.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    OlFDDIStatsPortEntry

olFDDIStatsPortEntry 1.3.6.1.4.1.49.2.3.1.5.4.3.1
A list of statistical information for each Port on each FDDI network in the concentrator.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  OlFDDIStatsPortEntry  

olFDDIStatsPortSlotIndex 1.3.6.1.4.1.49.2.3.1.5.4.3.1.1
The slot number that contains this Port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

olFDDIStatsPortIndex 1.3.6.1.4.1.49.2.3.1.5.4.3.1.2
The Port number of this port
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

olFDDIStatsPortLCTFailCts 1.3.6.1.4.1.49.2.3.1.5.4.3.1.3
The count of the consecutive times the link confidence test (LCT) has failed during connection management. Once the connection has been established, the count is zeroed. (refer to ANSI 9.4.1).
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

olFDDIStatsPortLerEstimate 1.3.6.1.4.1.49.2.3.1.5.4.3.1.4
A long term average link error rate. It ranges from 10**-4 to 10**-15 and is reported as the absolute value of the exponent of the estimate (the larger the number, the smaller the value).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

olFDDIStatsPortLemRejectCts 1.3.6.1.4.1.49.2.3.1.5.4.3.1.5
A link error monitoring count of the times that a link has been removed from the ring due to the LerCutOff threshold being exceeded.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

olFDDIStatsPortLemCts 1.3.6.1.4.1.49.2.3.1.5.4.3.1.6
The aggregate link error monitor error count, set to zero only on station power up. This variable's long term rate average is lerEstimate.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

olFDDInetStatsTable 1.3.6.1.4.1.49.2.3.1.5.4.4
A table of statistical information counted for each FDDI network in the concentrator
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    OlFDDInetStatsEntry

olFDDInetStatsEntry 1.3.6.1.4.1.49.2.3.1.5.4.4.1
A list of statistical information for each FDDI network in the concentrator.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  OlFDDInetStatsEntry  

olFDDInetStatsNetID 1.3.6.1.4.1.49.2.3.1.5.4.4.1.1
The network index that uniquely identifies this network. One of isolated, fddi-1, fddi-2, fddi-3, or fddi-4.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER isolated(2), fddi-1(16), fddi-2(17), fddi-3(18), fddi-4(19)  

olFDDInetStatsRingOpCounts 1.3.6.1.4.1.49.2.3.1.5.4.4.1.2
The number times the ring transitioned to operational.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

olFDDInetStatsFrameCounts 1.3.6.1.4.1.49.2.3.1.5.4.4.1.3
Frame-Ct (refer to ANSI MAC 2.2.1).
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

olFDDInetStatsErrorCounts 1.3.6.1.4.1.49.2.3.1.5.4.4.1.4
Error-Ct (refer to ANSI MAC 2.2.1).
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

olFDDInetStatsLostCounts 1.3.6.1.4.1.49.2.3.1.5.4.4.1.5
Lost-Ct (refer to ANSI MAC 2.2.1).
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

olFDDInetStatsFrameErrorRatio 1.3.6.1.4.1.49.2.3.1.5.4.4.1.6
This attribute is the actual ratio, ((delta snmpFddiMACLostCt + delta snmpFddiMACErrorCt) / (delta snmpFddiMACFrameCt + delta snmpFddiMACLostCt)) x 2**16.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..65535  

olGroupPortTable 1.3.6.1.4.1.49.2.3.1.6.1
A list of groups that each port is in. Each port can can be in 0, 1, or many groups.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    OlGroupPortEntry

olGroupPortEntry 1.3.6.1.4.1.49.2.3.1.6.1.1
The groups corresponding to a particular port.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  OlGroupPortEntry  

olGroupPortSlotIndex 1.3.6.1.4.1.49.2.3.1.6.1.1.1
The slot number that contains this port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

olGroupPortIndex 1.3.6.1.4.1.49.2.3.1.6.1.1.2
The port number within this slot. Logical ports can not be put into groups.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

olGroupPortGroupID 1.3.6.1.4.1.49.2.3.1.6.1.1.3
The group(s) to which the port has been assigned.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(0..8)  

olGroupSummaryTable 1.3.6.1.4.1.49.2.3.1.6.2
A table of condensed group information listing all the ports in each group.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    OlGroupSummaryEntry

olGroupSummaryEntry 1.3.6.1.4.1.49.2.3.1.6.2.1
The summary of all the ports in a particular group.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  OlGroupSummaryEntry  

olGroupSummaryGroupID 1.3.6.1.4.1.49.2.3.1.6.2.1.1
The group to which the ports have been assigned. A port can be in one or more groups.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER group-1(1), group-2(2), group-3(3), group-4(4), group-5(5), group-6(6), group-7(7), group-8(8)  

olGroupSummaryIndex 1.3.6.1.4.1.49.2.3.1.6.2.1.2
The index into the summary array. Up to 256 ports will be shown in olGroupSummaryPorts for each value in this entry.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

olGroupSummaryPorts 1.3.6.1.4.1.49.2.3.1.6.2.1.3
A condensed list of all the ports in this group. The summary is in the format: Slotx PortX SlotY PortY ...
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(0..1400)  

olGroupSet 1.3.6.1.4.1.49.2.3.1.6.3
OBJECT IDENTIFIER    

olGroupSetAction 1.3.6.1.4.1.49.2.3.1.6.3.1
This object specifies the action that we apply on a group. add-ports(1) adds port(s) to a group, clear-ports(2) clears (delete) port(s) from a group, and set-admin-state sets the Admin State of the group.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER add-ports(1), clear-ports(2), set-admin-state(3)  

olGroupSetGroupID 1.3.6.1.4.1.49.2.3.1.6.3.2
A group index that uniquely identifies this group. A port can be in zero, one, or more groups.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER group-1(1), group-2(2), group-3(3), group-4(4), group-5(5), group-6(6), group-7(7), group-8(8), all-groups(255)  

olGroupSetSlotIndex 1.3.6.1.4.1.49.2.3.1.6.3.3
This object specifies the slot number of the port(s) that are to be added/cleared to/from the group. This object should be set whenever add-ports(1) or clear-ports(2) are selected for olGroupSetAction. Value 254 refers to all non-existing ports, and value 255 refers to all slots which are only valid when olGroupSetAction is clear-ports(2).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

olGroupSetPortIndex 1.3.6.1.4.1.49.2.3.1.6.3.4
This object specifies the port number of the port(s) that are to be added/cleared to/from the group. This object should be set whenever add-ports(1) or clear-ports(2) are selected for olGroupSetAction. Value 255 refers to all ports.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

olGroupSetAdminState 1.3.6.1.4.1.49.2.3.1.6.3.5
This object specifies the Admin State that all the ports in the group defined by olGroupSetGroupID should be set to. This object should be set whenever set-admin-state(3) is selected for olGroupSetAction.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

olThreshTotalEntries 1.3.6.1.4.1.49.2.3.1.7.1.1.1
The number of entries currently in olThreshTable.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

olThreshMaxEntries 1.3.6.1.4.1.49.2.3.1.7.1.1.2
The maximum number of entries in olThreshTable supported by this agent.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

olThreshLastCreatedIndex 1.3.6.1.4.1.49.2.3.1.7.1.1.3
The index of the last entry in olThreshTable created via index 255 (see olThreshMode). If none, this value will be zero.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

olThreshAllMode 1.3.6.1.4.1.49.2.3.1.7.1.1.4
Provides the management station with a convenient way to set olThreshMode for all of the entries in ThreshTable. Setting olThreshAllMode to enable(1) or disable(2) will not cause new entries to be created; this will only affect entries that have presiously been created. Getting olThreshAllMode will always yield clear(3).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enable(1), disable(2), clear(3)  

olThreshTable 1.3.6.1.4.1.49.2.3.1.7.1.2
A list of thresholding entries.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    OlThreshEntry

olThreshEntry 1.3.6.1.4.1.49.2.3.1.7.1.2.1
A collection of variables for controlling and monitoring a specific threshold.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  OlThreshEntry  

olThreshIndex 1.3.6.1.4.1.49.2.3.1.7.1.2.1.1
An index that uniquely identifies an entry in the olThresh table. The number of entries in olTRThreshTable is olThreshTotalEntries. A new entry is created when a value is written to any object within the entry. An entry is removed when olThreshMode is set to clear(3). Index 255 references a 'pseudo entry' that allows the management station to create a new entry without having to search for a clear entry. When olThreshMode for entry 255 is set to disable or enable, if there is no available (clear) entry, then the SNMP set-response will indicate a bad value error, otherwise the agent does the following: - set the value of olThreshLastCreatedIndex to the index of the available entry - copy the values currently in entry 255 to the available entry - clear out entry 255.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

olThreshMode 1.3.6.1.4.1.49.2.3.1.7.1.2.1.2
The mode for this threshold. enable(1) indicates that this entry is in use and thresholding will be done. disable(2) indicates that this entry is in use but will no thresholding will be done. Setting olThreshMode to clear(3) will cause this entry to be removed from the table.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enable(1), disable(2), clear(3)  

olThreshDescription 1.3.6.1.4.1.49.2.3.1.7.1.2.1.3
Description of the threshold to be sent with the chipAboveThreshd trap.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..40)  

olThreshObjectIdentifier 1.3.6.1.4.1.49.2.3.1.7.1.2.1.4
The object identifier that specifies the statistic to be thresholded. The statistic to be thresholded can be specified either by setting olThreshObjectIdentifier or by setting values of the olThreshStat group of variables. When olThreshObjectIdentifier is set, the agent changes the values of the olThreshStat group of variables to refer to the new statistic to be thresholded. Similarly, when a olThreshStat variable is set, the agent changes olThreshObjectIdentifier to refer to the new statistic to be thresholded. A null object identifier (0.0) is used when no statistic is specified.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OBJECT IDENTIFIER  

olThreshStatCategory 1.3.6.1.4.1.49.2.3.1.7.1.2.1.5
Specifies the category of statistic to be thresholded. When olThreshStatCategory is network(2) or station(4), olThreshStatNetID must also be specified and olThreshStatSlotIndex will be overwritten as well. When olThreshStatCategory is station(4), olThreshStatStation must be specified. When olThreshStatCategory is port(3), olThreshStatSlotIndex and olThreshStatPortIndex must be specified. Modifying olThreshStatSlotIndex in this case will cause olThreshStatNetID to be overwritten as well.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER other(1), network(2), port(3), station(4)  

olThreshStatType 1.3.6.1.4.1.49.2.3.1.7.1.2.1.6
Specifies the type of statistic to be thresholded. error-frames(6) is valid only when olThreshStatCategory is port(3) or station(4). tr-net-soft-errors(7) or tr-net-hard-errors(8) is valid only when olThreshStatCategory is network(2). Note that tr-net-soft-errors(7) and tr-net-hard-errors(8) refer to dot5StatsSoftErrors and dot5StatsHardErrors, respectively. The other choices refer for items in the olTRTraf tables.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER other(1), frames(2), octets(3), broadcast-frames(4), multicast-frames(5), error-frames(6), tr-net-soft-errors(7), tr-net-hard-errors(8)  

olThreshStatNetID 1.3.6.1.4.1.49.2.3.1.7.1.2.1.7
When olThreshStatCategory is network(2) or station(4), specifies the network of statistic to be thresholded. If the agent is capable of collecting statistics only for the network that it is attached to, olThreshStatNetID can be set to agent-network(255); the agent will change olThreshStatNetID to reflect the network that the agent is currently attached to. If olThreshStatType is tr-net-soft-errors(7) or tr-net-hard-errors(8) the agent will change olThreshStatNetID to other(1). Note that when this variable is set, olThreshStatSlotIndex is overwritten as well.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER other(1), isolated(2), token-ring-1(9), token-ring-2(10), token-ring-3(11), token-ring-4(12), token-ring-5(13), token-ring-6(14), token-ring-7(15), agent-network(255)  

olThreshStatSlotIndex 1.3.6.1.4.1.49.2.3.1.7.1.2.1.8
When olThreshStatCategory is port(3), specifies the slot index of the port of statistic to be thresholded. Note that when this variable is set, olThreshStatNetID is overwritten as well.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

olThreshStatPortIndex 1.3.6.1.4.1.49.2.3.1.7.1.2.1.9
When olThreshStatCategory is port(3), specifies the port index of the port of statistic to be thresholded.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

olThreshStatStationAddr 1.3.6.1.4.1.49.2.3.1.7.1.2.1.10
When olThreshStatCategory is station(4), specifies the MAC address of the station of statistic to be thresholded.
Status: mandatory Access: read-write
OBJECT-TYPE    
  MacAddress  

olThreshInterval 1.3.6.1.4.1.49.2.3.1.7.1.2.1.11
Specifies the length of the thresholding period in seconds. Minimum length is 5 seconds; maximum is 86400 seconds (24 hours).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

olThreshCondition 1.3.6.1.4.1.49.2.3.1.7.1.2.1.12
Specifies the type of conditional comparison for the threshold.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER delta-above(1)  

olThreshValue 1.3.6.1.4.1.49.2.3.1.7.1.2.1.13
At the end of each thresholding interval (olThreshInterval seconds), olThreshCurrentValue is compared against olThreshValue (unsigned). When olThreshType is delta-above(1): If olThreshStatus is valid(4), and olThreshCurrentValue is above olThreshValue, and olThreshMode is enabled, then a chipAboveThreshd trap will be sent. Another chipAboveThreshd trap will not be sent until olThreshCurrentValue drops to less than or equal to olThreshValue and then again exceeds it.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

olThreshCurrentValue 1.3.6.1.4.1.49.2.3.1.7.1.2.1.14
When olThreshType is delta-exceed(1): The most recent delta value of olThreshStatObjectIdentifier (i.e. value of olThreshStatObjectIdentifier at the end of the interval minus the value of olThreshStatObjectIdentifier at the beginning of the interval). If olThreshStatus is not valid(4), olThreshCurrentValue will be 0.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

olThreshStatus 1.3.6.1.4.1.49.2.3.1.7.1.2.1.15
When olThreshType is delta-exceed(1): If olThreshStatObjectIdentifier has not yet been specified, olThreshStatus will be no-statistic-specified(1). If the first interval has not yet completed, olThreshStatus will be not-yet-available(2). If object referenced by olThreshStatObjectIdentifier is not accessible, olThreshStatus will be not-accessible(3). Otherwise olThreshStatus will be valid(4).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER no-statistic-specified(1), statistic-not-accessible(2), not-yet-available(3), valid(4)  

olThreshTimeSinceLastTriggered 1.3.6.1.4.1.49.2.3.1.7.1.2.1.16
Time in TimeTicks that has elapsed since a chipAboveThreshd trap associated with this ThreshEntry was last sent. If never sent, this value shall be zero.
Status: mandatory Access: read-only
OBJECT-TYPE    
  TimeTicks  

olThreshActionType 1.3.6.1.4.1.49.2.3.1.7.1.2.1.17
The action to be performed when the threshold is triggered.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER trap-only(1), run-script-only(2), trap-run-script(3)  

olThreshActionData 1.3.6.1.4.1.49.2.3.1.7.1.2.1.18
Additional information to be sent with the chipAboveThreshd trap. In the case of scripts, this object will contain the script number to be executed.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

olThreshActionPriority 1.3.6.1.4.1.49.2.3.1.7.1.2.1.19
The priority for this entry. Provided for use by the network management station (NMS) - not interpreted by the agent.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER low(1), medium(2), high(3)  

ocPowerModeAdminStatus 1.3.6.1.4.1.49.2.3.1.8.1.1
The current desired state of hub power fault-tolerant mode. Setting this object to fault-tolerant(1) will reserve one power supply's worth of power from the power budget for fault-tolerant operation, provided sufficient power is available. Setting this object to not-fault-tolerant(2) returns the reserved power to the power budget.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER fault-tolerant(1), not-fault-tolerant(2)  

ocPowerModeOperStatus 1.3.6.1.4.1.49.2.3.1.8.1.2
The current operational status of hub power fault-tolerant mode.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER fault-tolerant(1), not-fault-tolerant(2)  

ocPowerOverheatPowerDownMode 1.3.6.1.4.1.49.2.3.1.8.1.3
The current desired state of hub overheat automatic power- down mode. Setting this object to enable(1) will cause slots containing ONcore modules to be automatically power-disabled during a hub overheat condition. Setting this object to disable(2) will cause no action to be taken when a hub overheat condition occurs.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

ocPowerOutputTable 1.3.6.1.4.1.49.2.3.1.8.2
A table that contains information about the hub power budget. This table is indexed by voltage line type, each of which is supplied by the operational power supplies.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    OcPowerOutputEntry

ocPowerOutputEntry 1.3.6.1.4.1.49.2.3.1.8.2.1
A list of information about the hub power budget.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  OcPowerOutputEntry  

ocPowerOutputType 1.3.6.1.4.1.49.2.3.1.8.2.1.1
Identifies the power (voltage) line type for which this entry contains power budget information.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER plusFiveVolt(1), minusFiveVolt(2), plusTwelveVolt(3), minusTwelveVolt(4), plusTwoVolt(5)  

ocPowerOutputVoltageLevel 1.3.6.1.4.1.49.2.3.1.8.2.1.2
In millivolts (1/1000 Volt), the actual voltage level for this voltage type as sensed on the backplane. This voltage is supplied by all operational power supplies.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

ocPowerOutputWattageCapacity 1.3.6.1.4.1.49.2.3.1.8.2.1.3
In hundredths of a Watt (1/100 Watt), the maximum wattage for the voltage line that is output by all operational power supplies combined.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

ocPowerOutputWattageConsumed 1.3.6.1.4.1.49.2.3.1.8.2.1.4
In hundredths of a Watt (1/100 Watt), the wattage consumed by all hub modules. For a given voltage line, this object's value is the sum total of the power consumed by the hub itself, 2 Controller Modules, all installed ONline modules, and all power-enabled slots containing ONcore modules. If power fault-tolerant mode is enabled (when it was previously disabled), this object's value is increased by the amount of power reserved for the voltage line. If power fault-tolerant mode is disabled (when it was previously enabled), this object's value is decreased by the amount of power that is returned to the available power budget for the voltage line.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

ocPowerOutputWattageAvailable 1.3.6.1.4.1.49.2.3.1.8.2.1.5
In hundredths of a Watt (1/100 Watt), the wattage available to power-up modules. If power fault-tolerant mode is enabled (when it was previously disabled), this object's value is decreased by the amount of power reserved for the voltage line. If power fault-tolerant mode is disabled (when it was previously enabled), this object's value is increased by the amount of power that is returned to the available power budget for the voltage line.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

ocPowerOutputUnmanagedWattageAlloc 1.3.6.1.4.1.49.2.3.1.8.2.1.6
In hundredths of a Watt (1/100 Watt), the wattage allocated for modules that are not power-manageable (i.e., ONline modules).
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

ocPowerSlotTable 1.3.6.1.4.1.49.2.3.1.8.3
A table that contains power management information for each non-empty, payload slot in the hub.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    OcPowerSlotEntry

ocPowerSlotEntry 1.3.6.1.4.1.49.2.3.1.8.3.1
A list of power management information for each non-empty, payload slot in the hub.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  OcPowerSlotEntry  

ocPowerSlotIndex 1.3.6.1.4.1.49.2.3.1.8.3.1.1
The unique slot number that identifies the module associated with this power entry.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ocPowerSlotClass 1.3.6.1.4.1.49.2.3.1.8.3.1.2
The current slot power class. For a slot containing an ONcore module, this object's value ranges from 1 to 10, where 1 is the lowest power class and 10 is the highest power class. Slots assigned higher power classes will be power-enabled before slots assigned lower power classes. Similarly, slots assigned lower power classes will be power-disabled before slots assigned higher power classes. For a slot containing an ONline module, this object's value is reported as not-applicable(11) because ONline modules are not power-manageable (once an ONline module is inserted into the hub, it will consume power for as long as it remains in the hub). The value not-applicable(11) is invalid for a slot containing an ONcore module. Power class can be used to establish an ONcore module power-up and power-down priority scheme. Combined with slot location, slot power class defines the order in which slots containing ONcore modules will be power-enabled and power-disabled. For a given power class, slots are power-enabled from lowest payload slot to highest payload slot and power-disabled from highest payload slot to lowest payload slot. Slot power class is not pre-emptive; changing a slot's power class will not affect the power state of other slots. It will take effect during a slot power-up or power-down event (e.g., the failure or recovery of a power supply).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER one(1), two(2), three(3), four(4), five(5), six(6), seven(7), eight(8), nine(9), ten(10), not-applicable(11)  

ocPowerSlotAdminStatus 1.3.6.1.4.1.49.2.3.1.8.3.1.3
The current desired slot power state. For a slot containing an ONcore module, setting this object to enable(1) will cause the module to be power-enabled, provided sufficient power is available. Setting this object to disable(2) will cause the module to be power-disabled. The slot will not receive power until this object is set to the value enable(1). For a slot containing an ONline module, setting this object to disable(2) is invalid because an ONline module is not power-manageable; once installed, an ONline module comsumes power for as long as it remains in the hub. Also, for a slot containing the ONcore agent, setting this object to disable(2) is not allowed to prevent the user from losing hub manageability.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

ocPowerSlotOperStatus 1.3.6.1.4.1.49.2.3.1.8.3.1.4
The current operational slot power status. This object will have the value enabled(1), if the slot contains an ONcore module and is actually power-enabled. This object will have the value disabled(2), if the slot contains an ONcore module and is actually power-disabled. In this case, the slot is ineligible for power until ocPowerSlotAdminStatus for the slot is set to enable(1). This object will have the value insufficient-power(3), if the slot is eligible to receive power but, due to power constraints, is not power-enabled. When sufficient power becomes available, the slot will become power-enabled, and this object will then have the value enabled(1). This object will have the value enabled-always(4) for a slot containing an ONline module or the ONcore agent.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2), insufficient-power(3), enabled-always(4)  

ocInvHubType 1.3.6.1.4.1.49.2.3.1.9.1.1
The hub type (i.e. model number) of the hub. An instance for which information is not valid will return 'invalid EEPROM!'.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(1..32)  

ocInvHubSerialNo 1.3.6.1.4.1.49.2.3.1.9.1.2
The serial number of the hub. An instance for which information is not valid will return 'invalid EEPROM!'.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(1..32)  

ocInvHubHWVer 1.3.6.1.4.1.49.2.3.1.9.1.3
The revision number of the hardware of the hub. An instance for which information is not valid will return 'invalid EEPROM!'.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(1..32)  

ocInvHubMfr 1.3.6.1.4.1.49.2.3.1.9.1.4
The company name that manufactured this hub. An instance for which information is not valid will return 'invalid EEPROM!.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(1..32)  

ocInvHubMfrDate 1.3.6.1.4.1.49.2.3.1.9.1.5
The date in yymmdd format that this unit was manufactured. An instance for which information is not valid will return 'invalid EEPROM!'.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(6)  

ocInvModTable 1.3.6.1.4.1.49.2.3.1.9.2.1
A list of inventory information related to a module, indexed with respect to slot and subslot location numbers.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    OcInvModEntry

ocInvModEntry 1.3.6.1.4.1.49.2.3.1.9.2.1.1
Values to describe a module inventory items.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  OcInvModEntry  

ocInvModSlotIndex 1.3.6.1.4.1.49.2.3.1.9.2.1.1.1
The slot number where this Module is located.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ocInvModSubSlotIndex 1.3.6.1.4.1.49.2.3.1.9.2.1.1.2
The subslot number where this Module is located. It is associated with a slot number. Motherboards are always located in subslot one, (e.g. .1). However, daughter cards can reside on any subslot within the range (2 ... 8), (e.g. .<2 .. 8>).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ocInvModModel 1.3.6.1.4.1.49.2.3.1.9.2.1.1.3
This Module model number. If the instance value is unknown, ONline will be returned.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(1..32)  

ocInvModSerialNo 1.3.6.1.4.1.49.2.3.1.9.2.1.1.4
This Module serial number. If the instance value is unknown, N/A will be returned.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(1..32)  

ocInvModHWVer 1.3.6.1.4.1.49.2.3.1.9.2.1.1.5
The revision number of the hardware on this module. If the instant value is unknown, N/A will be returned.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(1..32)  

ocInvModSWVer 1.3.6.1.4.1.49.2.3.1.9.2.1.1.6
The revision number of the software on this module. If the instant value is unknown, N/A will be returned.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(1..32)  

ocInvModSWBootVer 1.3.6.1.4.1.49.2.3.1.9.2.1.1.7
The revision number of the boot software on this module. If the instant value is unknown, N/A will be returned.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(1..32)  

ocInvModMfr 1.3.6.1.4.1.49.2.3.1.9.2.1.1.8
The company name that manufactured this module. If the instant value is unkonwn, N/A will be returned.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(1..32)  

ocInvModMfrDate 1.3.6.1.4.1.49.2.3.1.9.2.1.1.9
The date in yymmdd format that this module was manufactured. If the instant value is unknown, N/A will be returned.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(6)  

olPS2Info 1.3.6.1.4.1.49.2.3.1.11.1
OBJECT IDENTIFIER    

olPS2OperatingSystem 1.3.6.1.4.1.49.2.3.1.11.1.1
The type of operating system current including its version and release numbers, currently executing on the PS/2.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..32)  

olPS2FixedDiskSize 1.3.6.1.4.1.49.2.3.1.11.1.2
The size in of Fixed Disk Memory currently installed on the PS/2.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..32)  

olPS2RamSize 1.3.6.1.4.1.49.2.3.1.11.1.3
The size in of Random Access Memory currently installed on the PS/2.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..32)  

olPS2McaTable 1.3.6.1.4.1.49.2.3.1.11.2
A table of software application information associated with the PS/2.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    OlPS2McaEntry

olPS2McaEntry 1.3.6.1.4.1.49.2.3.1.11.2.1
A profile of a specific software application associated with this PS/2.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  OlPS2McaEntry  

olPS2McaIndex 1.3.6.1.4.1.49.2.3.1.11.2.1.1
The index for this software application.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

olPS2McaDescription 1.3.6.1.4.1.49.2.3.1.11.2.1.2
A description of the software application.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..32)  

olPS2McaSlotConnectPoint 1.3.6.1.4.1.49.2.3.1.11.2.1.3
The slot number of a module within this ONline chassis to which this Micro channel Adapter Card is connected. If not connected to any ONline module module, the object value is zero.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

olPS2McaPortConnectPoint 1.3.6.1.4.1.49.2.3.1.11.2.1.4
The port number of a module within this ONline chassis to which this Micro channel Adapter Card is connected. If not connected to any ONline module module, the object value is zero.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

olPS2McaMacAddress 1.3.6.1.4.1.49.2.3.1.11.2.1.5
The MAC Address of the Micro channel adapter card installed this PS/2 Micro channel Adapter Card slot. If no MAC address is defined this string is encoded as a zero length string.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(6)  

olPS2ApplTable 1.3.6.1.4.1.49.2.3.1.11.3
A table of software application information associated with the PS/2.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    OlPS2ApplEntry

olPS2ApplEntry 1.3.6.1.4.1.49.2.3.1.11.3.1
A profile of a specific software application associated with this PS/2.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  OlPS2ApplEntry  

olPS2ApplIndex 1.3.6.1.4.1.49.2.3.1.11.3.1.1
The index for this software application.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

olPS2ApplDescription 1.3.6.1.4.1.49.2.3.1.11.3.1.2
A description of the software application.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..32)  

expDot5Table 1.3.6.1.4.1.49.2.4.1.1.1
This table contains Token Ring interface parameters and state variables, one entry per 802.5 interface.
Status: obsolete Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ExpDot5Entry

expDot5Entry 1.3.6.1.4.1.49.2.4.1.1.1.1
A list of Token Ring status and parameter values for an 802.5 interface.
Status: obsolete Access: not-accessible
OBJECT-TYPE    
  ExpDot5Entry  

expDot5IfIndex 1.3.6.1.4.1.49.2.4.1.1.1.1.1
The value of this object identifies the 802.5 interface for which this entry contains management information. The value of this object for a particular interface has the same value as the ifIndex object, defined in [4,6], for the same interface.
Status: obsolete Access: read-only
OBJECT-TYPE    
  INTEGER  

expDot5Commands 1.3.6.1.4.1.49.2.4.1.1.1.1.2
When this object is set to the value of open(2), the station should go into the open state. The progress and success of the open is given by the values of the objects expDot5RingState and expDot5RingOpenStatus. When this object is set to the value of reset(3), then the station should do a reset. On a reset, all MIB counters should retain their values, if possible. Other side affects are dependent on the hardware chip set. When this object is set to the value of close(4), the station should go into the stopped state by removing itself from the ring. Setting this object to a value of no-op(1) has no effect. When read, this object always has a value of no-op(1).
Status: obsolete Access: read-write
OBJECT-TYPE    
  INTEGER no-op(1), open(2), reset(3), close(4)  

expDot5RingStatus 1.3.6.1.4.1.49.2.4.1.1.1.1.3
The current interface status which can be used to diagnose fluctuating problems that can occur on token rings, after a station has successfully been added to the ring. Before an open is completed, this object has the value for the 'no status' condition. The expDot5RingState and expDot5RingOpenStatus objects provide for debugging problems when the station can not even enter the ring. The object's value is a sum of values, one for each currently applicable condition. The following values are defined for various conditions: 0 = No Problems detected 32 = Ring Recovery 64 = Single Station 256 = Remove Received 512 = reserved 1024 = Auto-Removal Error 2048 = Lobe Wire Fault 4096 = Transmit Beacon 8192 = Soft Error 16384 = Hard Error 32768 = Signal Loss 131072 = no status, open not completed.
Status: obsolete Access: read-only
OBJECT-TYPE    
  INTEGER  

expDot5RingState 1.3.6.1.4.1.49.2.4.1.1.1.1.4
The current interface state with respect to entering or leaving the ring.
Status: obsolete Access: read-only
OBJECT-TYPE    
  INTEGER opened(1), closed(2), opening(3), closing(4), openFailure(5), ringFailure(6)  

expDot5RingOpenStatus 1.3.6.1.4.1.49.2.4.1.1.1.1.5
This object indicates the success, or the reason for failure, of the station's most recent attempt to enter the ring.
Status: obsolete Access: read-only
OBJECT-TYPE    
  INTEGER noOpen(1), badParam(2), lobeFailed(3), signalLoss(4), insertionTimeout(5), ringFailed(6), beaconing(7), duplicateMAC(8), requestFailed(9), removeReceived(10), open(11)  

expDot5RingSpeed 1.3.6.1.4.1.49.2.4.1.1.1.1.6
The ring's bandwidth.
Status: obsolete Access: read-write
OBJECT-TYPE    
  INTEGER unknown(1), oneMegabit(2), fourMegabit(3), sixteenMegabit(4)  

expDot5UpStream 1.3.6.1.4.1.49.2.4.1.1.1.1.7
The MAC-address of the up stream neighbor station in the ring.
Status: obsolete Access: read-only
OBJECT-TYPE    
  MacAddress  

expDot5ActMonParticipate 1.3.6.1.4.1.49.2.4.1.1.1.1.8
If this object has a value of true(1) then this interface will participate in the active monitor selection process. If the value is false(2) then it will not. Setting this object might not have an effect until the next time the interface is opened.
Status: obsolete Access: read-write
OBJECT-TYPE    
  INTEGER true(1), false(2)  

expDot5Functional 1.3.6.1.4.1.49.2.4.1.1.1.1.9
The bit mask of all Token Ring functional addresses for which this interface will accept frames.
Status: obsolete Access: read-write
OBJECT-TYPE    
  MacAddress  

expDot5StatsTable 1.3.6.1.4.1.49.2.4.1.1.2
A table containing Token Ring statistics, one entry per 802.5 interface. All the statistics are defined using the syntax Counter as 32-bit wrap around counters. Thus, if an interface's hardware maintains these statistics in 16-bit counters, then the agent must read the hardware's counters frequently enough to prevent loss of significance, in order to maintain 32-bit counters in software.
Status: obsolete Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ExpDot5StatsEntry

expDot5StatsEntry 1.3.6.1.4.1.49.2.4.1.1.2.1
An entry contains the 802.5 statistics for a particular interface.
Status: obsolete Access: not-accessible
OBJECT-TYPE    
  ExpDot5StatsEntry  

expDot5StatsIfIndex 1.3.6.1.4.1.49.2.4.1.1.2.1.1
The value of this object identifies the 802.5 interface for which this entry contains management information. The value of this object for a particular interface has the same value as the ifIndex object, defined in [4,6], for the same interface.
Status: obsolete Access: read-only
OBJECT-TYPE    
  INTEGER  

expDot5StatsLineErrors 1.3.6.1.4.1.49.2.4.1.1.2.1.2
This counter is incremented when a frame or token is copied or repeated by a station, the E bit is zero in the frame or token and one of the following conditions exists: 1) there is a non-data bit (J or K bit) between the SD and the ED of the frame or token, or 2) there is an FCS error in the frame.
Status: obsolete Access: read-only
OBJECT-TYPE    
  Counter  

expDot5StatsBurstErrors 1.3.6.1.4.1.49.2.4.1.1.2.1.3
This counter is incremented when a station detects the absence of transitions for five half-bit timers (burst-five error).
Status: obsolete Access: read-only
OBJECT-TYPE    
  Counter  

expDot5StatsACErrors 1.3.6.1.4.1.49.2.4.1.1.2.1.4
This counter is incremented when a station receives an AMP or SMP frame in which A is equal to C is equal to 0, and then receives another SMP frame with A is equal to C is equal to 0 without first receiving an AMP frame. It denotes a station that cannot set the AC bits properly.
Status: obsolete Access: read-only
OBJECT-TYPE    
  Counter  

expDot5StatsAbortTransErrors 1.3.6.1.4.1.49.2.4.1.1.2.1.5
This counter is incremented when a station transmits an abort delimiter while transmitting.
Status: obsolete Access: read-only
OBJECT-TYPE    
  Counter  

expDot5StatsInternalErrors 1.3.6.1.4.1.49.2.4.1.1.2.1.6
This counter is incremented when a station recognizes an internal error.
Status: obsolete Access: read-only
OBJECT-TYPE    
  Counter  

expDot5StatsLostFrameErrors 1.3.6.1.4.1.49.2.4.1.1.2.1.7
This counter is incremented when a station is transmitting and its TRR timer expires. This condition denotes a condition where a transmitting station in strip mode does not receive the trailer of the frame before the TRR timer goes off.
Status: obsolete Access: read-only
OBJECT-TYPE    
  Counter  

expDot5StatsReceiveCongestions 1.3.6.1.4.1.49.2.4.1.1.2.1.8
This counter is incremented when a station recognizes a frame addressed to its specific address, but has no available buffer space indicating that the station is congested.
Status: obsolete Access: read-only
OBJECT-TYPE    
  Counter  

expDot5StatsFrameCopiedErrors 1.3.6.1.4.1.49.2.4.1.1.2.1.9
This counter is incremented when a station recognizes a frame addressed to its specific address and detects that the FS field A bits are set to 1 indicating a possible line hit or duplicate address.
Status: obsolete Access: read-only
OBJECT-TYPE    
  Counter  

expDot5StatsTokenErrors 1.3.6.1.4.1.49.2.4.1.1.2.1.10
This counter is incremented when a station acting as the active monitor recognizes an error condition that needs a token transmitted.
Status: obsolete Access: read-only
OBJECT-TYPE    
  Counter  

expDot5StatsSoftErrors 1.3.6.1.4.1.49.2.4.1.1.2.1.11
The number of Soft Errors the interface has detected. It directly corresponds to the number of Report Error MAC frames that this interface has transmitted. Soft Errors are those which are recoverable by the MAC layer protocols.
Status: obsolete Access: read-only
OBJECT-TYPE    
  Counter  

expDot5StatsHardErrors 1.3.6.1.4.1.49.2.4.1.1.2.1.12
The number of times this interface has detected an immediately recoverable fatal error. It denotes the number of times this interface is either transmitting or receiving beacon MAC frames.
Status: obsolete Access: read-only
OBJECT-TYPE    
  Counter  

expDot5StatsSignalLoss 1.3.6.1.4.1.49.2.4.1.1.2.1.13
The number of times this interface has detected the loss of signal condition from the ring.
Status: obsolete Access: read-only
OBJECT-TYPE    
  Counter  

expDot5StatsTransmitBeacons 1.3.6.1.4.1.49.2.4.1.1.2.1.14
The number of times this interface has transmitted a beacon frame.
Status: obsolete Access: read-only
OBJECT-TYPE    
  Counter  

expDot5StatsRecoverys 1.3.6.1.4.1.49.2.4.1.1.2.1.15
The number of Claim Token MAC frames received or transmitted after the interface has received a Ring Purge MAC frame. This counter signifies the number of times the ring has been purged and is being recovered back into a normal operating state.
Status: obsolete Access: read-only
OBJECT-TYPE    
  Counter  

expDot5StatsLobeWires 1.3.6.1.4.1.49.2.4.1.1.2.1.16
The number of times the interface has detected an open or short circuit in the lobe data path. The adapter will be closed and expDot5RingState will signify this condition.
Status: obsolete Access: read-only
OBJECT-TYPE    
  Counter  

expDot5StatsRemoves 1.3.6.1.4.1.49.2.4.1.1.2.1.17
The number of times the interface has received a Remove Ring Station MAC frame request. When this frame is received the interface will enter the close state and expDot5RingState will signify this condition.
Status: obsolete Access: read-only
OBJECT-TYPE    
  Counter  

expDot5StatsSingles 1.3.6.1.4.1.49.2.4.1.1.2.1.18
The number of times the interface has sensed that it is the only station on the ring. This will happen if the interface is the first one up on a ring, or if there is a hardware problem.
Status: obsolete Access: read-only
OBJECT-TYPE    
  Counter  

expDot5StatsFreqErrors 1.3.6.1.4.1.49.2.4.1.1.2.1.19
The number of times the interface has detected that the frequency of the incoming signal differs from the expected frequency by more than that ispecified by the IEEE 802.5 standard, see chapter 7 in [10].
Status: obsolete Access: read-only
OBJECT-TYPE    
  Counter  

expDot5TimerTable 1.3.6.1.4.1.49.2.4.1.1.5
This table contains Token Ring interface timer values, one entry per 802.5 interface.
Status: obsolete Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ExpDot5TimerEntry

expDot5TimerEntry 1.3.6.1.4.1.49.2.4.1.1.5.1
A list of Token Ring timer values for an 802.5 interface.
Status: obsolete Access: not-accessible
OBJECT-TYPE    
  ExpDot5TimerEntry  

expDot5TimerIfIndex 1.3.6.1.4.1.49.2.4.1.1.5.1.1
The value of this object identifies the 802.5 interface for which this entry contains timer values. The value of this object for a particular interface has the same value as the ifIndex object, defined in [4,6], for the same interface.
Status: obsolete Access: read-only
OBJECT-TYPE    
  INTEGER  

expDot5TimerReturnRepeat 1.3.6.1.4.1.49.2.4.1.1.5.1.2
The time-out value used to ensure the interface will return to Repeat State, in units of 100 micro-seconds. The value should be greater than the maximum ring latency. Implementors are encouraged to provide read-write access to this object if that is possible/useful in their system, but giving due consideration to the dangers of write-able timers.
Status: obsolete Access: read-only
OBJECT-TYPE    
  INTEGER  

expDot5TimerHolding 1.3.6.1.4.1.49.2.4.1.1.5.1.3
Maximum period of time a station is permitted to transmit frames after capturing a token, in units of 100 micro-seconds. Implementors are encouraged to provide read-write access to this object if that is possible/useful in their system, but giving due consideration to the dangers of write-able timers.
Status: obsolete Access: read-only
OBJECT-TYPE    
  INTEGER  

expDot5TimerQueuePDU 1.3.6.1.4.1.49.2.4.1.1.5.1.4
The time-out value for enqueuing of an SMP PDU after reception of an AMP or SMP frame in which the A and C bits were equal to 0, in units of 100 micro-seconds. Implementors are encouraged to provide read-write access to this object if that is possible/useful in their system, but giving due consideration to the dangers of write-able timers.
Status: obsolete Access: read-only
OBJECT-TYPE    
  INTEGER  

expDot5TimerValidTransmit 1.3.6.1.4.1.49.2.4.1.1.5.1.5
The time-out value used by the active monitor to detect the absence of valid transmissions, in units of 100 micro-seconds. Implementors are encouraged to provide read-write access to this object if that is possible/useful in their system, but giving due consideration to the dangers of write-able timers.
Status: obsolete Access: read-only
OBJECT-TYPE    
  INTEGER  

expDot5TimerNoToken 1.3.6.1.4.1.49.2.4.1.1.5.1.6
The time-out value used to recover from various-related error situations [9]. If N is the maximum number of stations on the ring, the value of this timer is normally: expDot5TimerReturnRepeat + N*expDot5TimerHolding. Implementors are encouraged to provide read-write access to this object if that is possible/useful in their system, but giving due consideration to the dangers of write-able timers.
Status: obsolete Access: read-only
OBJECT-TYPE    
  INTEGER  

expDot5TimerActiveMon 1.3.6.1.4.1.49.2.4.1.1.5.1.7
The time-out value used by the active monitor to stimulate the enqueuing of an AMP PDU for transmission, in units of 100 micro-seconds. Implementors are encouraged to provide read-write access to this object if that is possible/useful in their system, but giving due consideration to the dangers of write-able timers.
Status: obsolete Access: read-only
OBJECT-TYPE    
  INTEGER  

expDot5TimerStandbyMon 1.3.6.1.4.1.49.2.4.1.1.5.1.8
The time-out value used by the stand-by monitors to ensure that there is an active monitor on the ring and to detect a continuous stream of tokens, in units of 100 micro-seconds. Implementors are encouraged to provide read-write access to this object if that is possible/useful in their system, but giving due consideration to the dangers of write-able timers.
Status: obsolete Access: read-only
OBJECT-TYPE    
  INTEGER  

expDot5TimerErrorReport 1.3.6.1.4.1.49.2.4.1.1.5.1.9
The time-out value which determines how often a station shall send a Report Error MAC frame to report its error counters, in units of 100 micro-seconds. Implementors are encouraged to provide read-write access to this object if that is possible/useful in their system, but giving due consideration to the dangers of write-able timers.
Status: obsolete Access: read-only
OBJECT-TYPE    
  INTEGER  

expDot5TimerBeaconTransmit 1.3.6.1.4.1.49.2.4.1.1.5.1.10
The time-out value which determines how long a station shall remain in the state of transmitting Beacon frames before entering the Bypass state, in units of 100 micro-seconds. Implementors are encouraged to provide read-write access to this object if that is possible/useful in their system, but giving due consideration to the dangers of write-able timers.
Status: obsolete Access: read-only
OBJECT-TYPE    
  INTEGER  

expDot5TimerBeaconReceive 1.3.6.1.4.1.49.2.4.1.1.5.1.11
The time-out value which determines how long a station shall receive Beacon frames from its downstream neighbor before entering the Bypass state, in units of 100 micro-seconds. Implementors are encouraged to provide read-write access to this object if that is possible/useful in their system, but giving due consideration to the dangers of write-able timers.
Status: obsolete Access: read-only
OBJECT-TYPE    
  INTEGER  

expDot5Tests 1.3.6.1.4.1.49.2.4.1.1.3
OBJECT IDENTIFIER    

testInsertFunc 1.3.6.1.4.1.49.2.4.1.1.3.1
OBJECT IDENTIFIER    

expDot5ChipSets 1.3.6.1.4.1.49.2.4.1.1.4
OBJECT IDENTIFIER    

chipSetIBM16 1.3.6.1.4.1.49.2.4.1.1.4.1
OBJECT IDENTIFIER    

chipSetTItms380 1.3.6.1.4.1.49.2.4.1.1.4.2
OBJECT IDENTIFIER    

chipSetTItms380c16 1.3.6.1.4.1.49.2.4.1.1.4.3
OBJECT IDENTIFIER    

chipTTYNumber 1.3.6.1.4.1.49.2.5.1
The number of terminal ports on this agent product.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

chipTTYTable 1.3.6.1.4.1.49.2.5.2
A table of TTY specific information associated with this agent.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ChipTTYEntry

chipTTYEntry 1.3.6.1.4.1.49.2.5.2.1
A profile of a specific TTY interface associated with this agent.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  ChipTTYEntry  

chipTTYIndex 1.3.6.1.4.1.49.2.5.2.1.1
The TTY to which this entry refers.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

chipTTYBaud 1.3.6.1.4.1.49.2.5.2.1.2
The baud rate for this TTY. It should be noted that all serial ports do not support all of the above baud rates.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER one-hundred-ten(110), three-hundred(300), twelve-hundred(1200), twenty-four-hundred(2400), forty-eight-hundred(4800), ninety-six-hundred(9600), nineteen-two-hundred(19200), thirty-eight-thousand-four-hundred(38400)  

chipTTYParity 1.3.6.1.4.1.49.2.5.2.1.3
The parity setting for this TTY.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER odd(1), even(2), none(3)  

chipTTYStop 1.3.6.1.4.1.49.2.5.2.1.4
The number of stop bits for this TTY.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER one(1), two(2)  

chipTTYData 1.3.6.1.4.1.49.2.5.2.1.5
The number of data bits for this TTY.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER seven(7), eight(8)  

chipTTYTimeout 1.3.6.1.4.1.49.2.5.2.1.6
The number of minutes to wait before this agent logs out an inactive login session on this TTY. NOTE: In some implementations, this is a single variable that is used by all of the terminal and telnet sessions.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

chipTTYPrompt 1.3.6.1.4.1.49.2.5.2.1.7
The terminal prompt to display on this TTY. NOTE: In some implementations, this is a single variable that is used by all of the terminal and telnet sessions.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..15)  

chipTTYDTR 1.3.6.1.4.1.49.2.5.2.1.8
This value dictates the behavior of the RS-232 Data Terminal Ready (DTR) signal at the time a session ends due to a logout, timeout, or shutdown. This is used by some modems as an indication that they should hangup. This variable returns notApplicable(3) if the RS-232 port does not have a DTR signal.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER asserted(1), deasserted(2), notApplicable(3)  

chipTTYTerminalType 1.3.6.1.4.1.49.2.5.2.1.9
A string which indicates the type of terminal that is attached to the serial port. It should be noted that the string is passed to a telnet server whenever the server issues the IAC DO TERMINAL-TYPE command (see rfc884).
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(1..40)  

chipTFTPStart 1.3.6.1.4.1.49.2.6.1
Setting chipTFTPStart to tftpGet(2) initiates a file transfer to the agent (download); tftpPut(3) initiates a file transfer to the server (upload).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER tftpNoTransfer(1), tftpGet(2), tftpPut(3)  

chipTFTPSlot 1.3.6.1.4.1.49.2.6.2
The slot number of the module that is to be involved in the TFTP transfer with the TFTP server (chipTFTPIpAddress).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER slot-1(1), slot-2(2), slot-3(3), slot-4(4), slot-5(5), slot-6(6), slot-7(7), slot-8(8), slot-9(9), slot-10(10), slot-11(11), slot-12(12), slot-13(13), slot-14(14), slot-15(15), slot-16(16), slot-17(17), all-fddi-port-slots(254), agent-slot(255)  

chipTFTPIpAddress 1.3.6.1.4.1.49.2.6.3
The IP Address of the TFTP server.
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

chipTFTPFileName 1.3.6.1.4.1.49.2.6.4
The file name of the file to retrieve (tftpGet), or the name of the file to create (tftpPut).
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..128)  

chipTFTPFileType 1.3.6.1.4.1.49.2.6.5
The type of file image to upload/download. The file type indicates to the agent what kind of file it is receiving. flashCode(1) indicates a code upgrade of the operational proms. bootCode(2) indicates a code upgrade of the boot proms. ascii(3) indicates an ASCII file.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER flashCode(1), bootCode(2), ascii(3)  

chipTFTPResult 1.3.6.1.4.1.49.2.6.6
The result of the last TFTP operation.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER clear(1), xferInProgress(2), okay(3), otherTFTPError(4), fileNotFound(5), accessError(6), diskFull(7), illegalTFTPOperation(8), invalidTFTPTransactionID(9), noResponse(10), invalidDownloadKey(11), invalidSlot(12), invalidNetwork(13), fepromErase(14), fepromProg(15), xferError(16), decodeError(17), dlInProgress(18), notYetSupported(19), noModsOfType(20), downloadFailed(21), crcError(22), invalidDLType(23), unknownFEPROMType(24), fileTooLarge(25), fileGetProblem(26), notMaster(27), onlyOperational(28), rejectedByTarget(29), gatewayUnreachable(30), moduleTypeError(31), fileTypeError(32), fileForwardProblem(33), notifyTargetError(34), serverTimeout(35), noModuleInSlot(36), targetTimeout(37)  

chipTFTPSubSlot 1.3.6.1.4.1.49.2.6.7
The subslot identifier for the module to be involved in the TFTP transfer with the TFTP server. If this transfer involves a module not contained in the ONcore system, the value of this object can only be 1. If the value of chipTFTPSlot is agent-slot(255), this object is ignored.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

chipTFTPTargetLocation 1.3.6.1.4.1.49.2.6.8
Specifies the ultimate destination of the file being transfered. This object will determine if the target is Device or Module.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER target-Device(1), target-SlotSubSlot(2)  

chipDownloadUDKSerial 1.3.6.1.4.1.49.2.7.1
A string representing the serial number of the Upgrade Distribution Kit.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..8)  

chipDownloadKey 1.3.6.1.4.1.49.2.7.2
The key code provided by your VAR. Available by calling technical support at +1 508 460 6195.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..8)  

chipDownloadDateTime 1.3.6.1.4.1.49.2.7.3
The date of the last successful download in the format hh:mm day DD Mon YY
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..20)  

chipAlertTable 1.3.6.1.4.1.49.2.8.1
A table of entries associated with the management of alerts on this agent.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ChipAlertEntry

chipAlertEntry 1.3.6.1.4.1.49.2.8.1.1
An entry associated with the management of an alert on this agent.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  ChipAlertEntry  

chipAlertIndex 1.3.6.1.4.1.49.2.8.1.1.1
The specific alert to manage. snmp-authentication(1) manages the standard authentication failure trap. hello(2) manages the hello trap. change(3), the change traps. console-display(4) controls the display of alerts at the console terminal. port-up-down(5) controls the generation of port up and port down traps.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER snmp-authentication(1), hello(2), change(3), console-display(4), port-up-down(5)  

chipAlertMode 1.3.6.1.4.1.49.2.8.1.1.2
Enabling a specific alert allows that alert to be generated, or displayed at the console. If chipAlertIndex is set to port-up-down(5) then this object either overrides the port filter database by enabling or disabling all port alerts, or if this object is set to filter(3), then olPortAlertFilter in the olPortTable is consulted for when generating alerts for each individual port. Note that only port-up-down(5) alerts may be filtered. Setting this object to filter(3) for entries other than port-up-down(5) will return the invalidData object.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enable(1), disable(2), filter(3)  

chipBootPStart 1.3.6.1.4.1.49.2.11.1
Setting chipBootPStart to bootpRequest(2) initiates an BootP request to obtain configuration information from a BootP server.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER bootpNoTransfer(1), bootpRequest(2)  

chipBootPPowerUpMode 1.3.6.1.4.1.49.2.11.2
When set to enable(1) indicates that a BootP request to obtain configuration information should be initiated following a power-up sequence.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

chipBootPIpAddress 1.3.6.1.4.1.49.2.11.3
The IP Address of the BootP server. If no IP address is defined, the broadcast address will be used in a BootP request.
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

chipBootPResult 1.3.6.1.4.1.49.2.11.4
The result of the last BootP operation.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER clear(1), xferInProgress(2), okay(3), noBootPResponse(4), otherBootPError(5)  

chipHello 1
A chipHello trap is sent every minute by an agent with the hello trap enabled. The hello trap will discontinue being sent when either the agent receives an authenticate SNMP request, or after 255 minutes.
TRAP-TYPE    

chipSlotDown 2
This trap indicates that the module in the indicated slot is down. Usually, this trap is sent when the module has been removed. Sometimes, this trap is sent when management communications with this module have been broken. In this case, it may not be possible to distinguish between a removed and a failed module. The module type (olModType) and the module description (olModDescr) are also provided in this case.
TRAP-TYPE    

chipSlotUp 3
This trap indicates that a blade in the indicated slot is up. Usually, this trap is sent when the module is inserted into the hub. Sometimes, this trap is sent when management communications have been restored to a module where they had previously been broken. In this case, it may not be possible to distinguish between a module that has just be inserted and a module that has just the. The module type (olModType) and the module description (olModDescr) are also provided in this case.
TRAP-TYPE    

chipEnvironment 4
A chipEnvironment trap indicates a change in the concentrator's environment has occurred. The variables supplied indicate what exactly changed.
TRAP-TYPE    

chipHardware 5
A chipHardware trap indicates that a soft hardware failure has been detected. An example of a soft hardware failure is too many writes to non-vatile storage. This is an indication to get the unit serviced.
TRAP-TYPE    

chipSoftware 6
A chipSoftware trap indicates that a soft software failure has been detected. This is an indication to get the unit serviced.
TRAP-TYPE    

chipChange 7
A chipChange trap is used to indicate that a configuration change has occurred. The actual variables that changed are included in the variables section of the PDU.
TRAP-TYPE    

chipFatal 8
A chipFatal trap is used to indicate that a fatal error has occurred. This is an indication to get the unit serviced.
TRAP-TYPE    

chipTrunkDown 9
A chipTrunkDown trap indicates that trunk's status has changed to an error condition. Multiple chipTrunkDown traps may be sent if the trunk's status changes from one error to another.
TRAP-TYPE    

chipTrunkUp 10
A chipTrunkUp trap indicates that a trunk's status has changed to a non-error (okay or warning) condition.
TRAP-TYPE    

chipPortDown 11
A chipPortDown trap indicates that a port's status has changed to an error condition. Multiple chipPortDown traps may be sent if the port's status changes from one error to another.
TRAP-TYPE    

chipPortUp 12
A chipPortUp trap indicates that a port's status has changed to a non-error (okay or warning) condition.
TRAP-TYPE    

chipPing 13
A chipPing trap is sent after the SNMP initiated PING command is completed. After the last echo request packet is sent, this trap is sent indicating the ping address, the number of requests sent, and the number of responses received at the time the trap was generated.
TRAP-TYPE    

chipAboveThreshd 14
A chipAboveThreshd trap indicates that a Counter or Gauge variable has exceeded its threshd. The variable which is above its threshd is the only variable in the varBind list. Its value is taken at the time the threshd calculation is performed and therefore may be greater than the actual threshd value. Another above threshd trap will not be sent until a below threshd trap is sent.
TRAP-TYPE    

chipBelowThreshd 15
A chipBelowThreshd trap indicates that a Counter or Gauge variable had exceeded its threshd but is now below its threshd. The variable which is below its threshd is the only variable in the varBind list. Its value is taken at the time the threshd calculation is performed and therefore may be less than the actual threshd value. Another below threshd trap will not be sent until an above threshd trap is sent.
TRAP-TYPE    

chipModuleDown 16
A chipSlotDown trap indicates that management communications with the slot indicated by chipModSlotIndex has been broken. This event usually occurs when a module has been physically removed from the concentrator. However, it is possible for this event to occur when the particular module fails.
TRAP-TYPE    

chipModuleUp 17
A chipSlotUp trap indicates that management communications with the slot indicated by chipModSlotIndex has been established. This event usually occurs when a module has physically been inserted into the concentrator. The variable chipModType indicates the module type inserted. For
TRAP-TYPE    

chipSecurity 18
This trap indicates a change in the security environment. The olNetOlSecTrapReason specifies the reason for the trap. If the trap reason is intrusion-attempt(2), then the following objects will also be included in the trap: olPortSlotIndex and olPortPortIndex (to specify on which port the intrusion attempt occurred), and olPortAdminState (to indicate whether the port was automatically disabled). The olEnetStatsPortLastSrcAddr object will be included if the MAC address of the intruder is available.
TRAP-TYPE