CERENT-ENVMON-MIB

File: CERENT-ENVMON-MIB.mib (8182 bytes)

Imported modules

CERENT-GLOBAL-REGISTRY SNMPv2-TC SNMPv2-CONF
SNMPv2-SMI

Imported symbols

cerentModules cerentRequirements cerentGeneric
DisplayString OBJECT-GROUP MODULE-COMPLIANCE
MODULE-IDENTITY OBJECT-IDENTITY OBJECT-TYPE
Gauge32 Integer32

Defined Types

CerentEnvMonVoltageStatsEntry  
SEQUENCE    
  cerentEnvMonVoltageStatsIndex Integer32
  cerentEnvMonVoltageStatsDescr DisplayString
  cerentEnvMonVoltageStatsCurrentValue Integer32
  cerentEnvMonVoltageStatsThresholdVeryHigh Integer32
  cerentEnvMonVoltageStatsThresholdHigh Integer32
  cerentEnvMonVoltageStatsThresholdLow Integer32
  cerentEnvMonVoltageStatsThresholdVeryLow Integer32

CerentEnvMonTemperatureStatsEntry  
SEQUENCE    
  cerentEnvMonTemperatureStatsIndex Integer32
  cerentEnvMonTemperatureStatsDescr DisplayString
  cerentEnvMonTemperatureStatsCurrentValue Gauge32
  cerentEnvMonTemperatureStatsThresholdHigh Gauge32

Defined Values

cerentEnvMonMIB 1.3.6.1.4.1.3607.1.10.120
This MIB module provides Environmental status information
MODULE-IDENTITY    

cerentEnvMonMibConformance 1.3.6.1.4.1.3607.5.70
This node is created for compliance. Has objects as required by the RFCs
Status: current Access: read-only
OBJECT-IDENTITY    

cerentEnvMonMibCompliance 1.3.6.1.4.1.3607.5.70.10
The compliance statements for Cisco ONS devices.
Status: current Access: read-only
OBJECT-IDENTITY    

cerentEnvMonMibGroups 1.3.6.1.4.1.3607.5.70.20
All the objects and events are grouped under this for conformance
Status: current Access: read-only
OBJECT-IDENTITY    

cerentEnvMonObjects 1.3.6.1.4.1.3607.2.80
Tok_String
Status: current Access: read-only
OBJECT-IDENTITY    

cerentEnvMonVoltageStatsTable 1.3.6.1.4.1.3607.2.80.10
This table maintains the status info for all EnvMon related voltages picked up by the sensors in the device.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    CerentEnvMonVoltageStatsEntry

cerentEnvMonVoltageStatsEntry 1.3.6.1.4.1.3607.2.80.10.1
There will as many rows as there are sensors in the device.
Status: current Access: not-accessible
OBJECT-TYPE    
  CerentEnvMonVoltageStatsEntry  

cerentEnvMonVoltageStatsIndex 1.3.6.1.4.1.3607.2.80.10.1.10
The value index uniquely indicates the voltage sensor in the device.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 1..2147483647  

cerentEnvMonVoltageStatsDescr 1.3.6.1.4.1.3607.2.80.10.1.20
Unique Name/Description of the voltage sensor.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

cerentEnvMonVoltageStatsCurrentValue 1.3.6.1.4.1.3607.2.80.10.1.30
Current voltage measurement at this voltage sensor.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

cerentEnvMonVoltageStatsThresholdVeryHigh 1.3.6.1.4.1.3607.2.80.10.1.40
If the current voltage value exceeds this threshold value, an alarm event will be raised by the device. The severity of this event may be provisionable.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

cerentEnvMonVoltageStatsThresholdHigh 1.3.6.1.4.1.3607.2.80.10.1.50
If the current voltage value exceeds this threshold value, a warning event will be raised by the device. The severity of this event may be provisionable.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

cerentEnvMonVoltageStatsThresholdLow 1.3.6.1.4.1.3607.2.80.10.1.60
If the current voltage value falls below this threshold value, a warning event will be raised by the device. The severity of this event may be provisionable.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

cerentEnvMonVoltageStatsThresholdVeryLow 1.3.6.1.4.1.3607.2.80.10.1.70
If the current voltage value falls below this threshold value, an alarm event will be raised by the device. The severity of this event may be provisionable.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

cerentEnvMonTemperatureStatsTable 1.3.6.1.4.1.3607.2.80.20
This table provides ambient temperature information as measured by the temperature sensors.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    CerentEnvMonTemperatureStatsEntry

cerentEnvMonTemperatureStatsEntry 1.3.6.1.4.1.3607.2.80.20.1
Each temperature is represented by a row in the table.
Status: current Access: not-accessible
OBJECT-TYPE    
  CerentEnvMonTemperatureStatsEntry  

cerentEnvMonTemperatureStatsIndex 1.3.6.1.4.1.3607.2.80.20.1.10
The value index uniquely indicates the temperature sensor in the device.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 1..2147483647  

cerentEnvMonTemperatureStatsDescr 1.3.6.1.4.1.3607.2.80.20.1.20
Unique Name/Description of the temperature sensor.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

cerentEnvMonTemperatureStatsCurrentValue 1.3.6.1.4.1.3607.2.80.20.1.30
Current Temperature measurement at this temperature sensor.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

cerentEnvMonTemperatureStatsThresholdHigh 1.3.6.1.4.1.3607.2.80.20.1.40
If the current temperature value exceeds this threshold value, an alarm event will be raised by the device. The severity of this event may be provisionable.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

cerentEnvMonMibObjectsGroup 1.3.6.1.4.1.3607.5.70.20.10
All NMS accessible objects
Status: current Access: read-only
OBJECT-GROUP    

cerentEnvMonMibBasicCompliance 1.3.6.1.4.1.3607.5.70.10.10
The basic implementation requirements for all Cisco ONS network devices.
Status: current Access: read-only
MODULE-COMPLIANCE