CERENT-454-MIB

File: CERENT-454-MIB.mib (723627 bytes)

Imported modules

SNMPv2-SMI SNMPv2-TC SNMPv2-CONF
CERENT-GLOBAL-REGISTRY CERENT-TC

Imported symbols

MODULE-IDENTITY OBJECT-TYPE OBJECT-IDENTITY
NOTIFICATION-TYPE Integer32 Unsigned32
Counter32 TEXTUAL-CONVENTION DisplayString
TruthValue TimeStamp MODULE-COMPLIANCE
OBJECT-GROUP NOTIFICATION-GROUP cerentProducts
cerentModules CerentNotificationClass CerentAlarmSeverity
CerentAlarmStatus CerentAlarmServiceAffecting CerentMonitorType
CerentLocation CerentPeriod CerentPortNumber

Defined Types

Cerent454AlarmType  
TEXTUAL-CONVENTION    
  current INTEGER alarmUnknown(1), alarmCutoffIsInManualMode(10), failureDetectedExternalToTheNE(20), externalError(30), excessiveSwitching(40), sdccTerminationFailure(50), incomingFailureCondition(60), alarmIndicationSignal(70), alarmIndicationSignalLine(80), alarmIndicationSignalPath(90), alarmIndicationSignalVT(100), apsChannelFailure(110), channelByteFailureAPS(120), channelProtectionSwitchingChannelMatchFailureAPS(130), channelAutomaticProtectionSwitchModeMismatchAPS(140), farEndProtectionLineFailure(150), inconsistentAPSCode(160), improperAPSCode(170), nodeIdMismatch(180), channelDefaultKAPS(190), connectionLoss(200), bipolarViolation(210), carrierLossOnTheLAN(220), concatenationErrorSTS(230), excessCollisionsOnTheLAN(240), facilityFailure(250), farEndAIS(260), farEndMultipleDS1LOSDetectedOnDS3(270), farEndDS1EqptFailNonServiceAffecting(280), farEndDS1EqptFailServiceAffecting(290), farEndSingleDS1LOS(300), farEndDS3EqptFailNonServiceAffecting(310), farEndDS3EqptFailServiceAffecting(320), farEndCommonEquipmentFailureNonServiceAffecting(330), farEndIDLE(340), farEndLOS(350), farEndLOF(360), farEndBlockError(370), ds3IdleCondition(380), lossOfFrame(390), lossOfPointer(400), lossOfPointerPath(410), lossOfPointerVT(420), lossOfSignal(430), outOfFrame(440), pathSelectorFailure(450), remoteAlarmIndication(460), remoteFailureIndication(470), remoteFailureIndicationLine(480), remoteFailureIndicationPath(490), remoteFailureIndicationVT(500), signalDegrade(510), severelyErroredFrame(520), signalFailure(530), signalLabelMismatchFailure(540), payloadDefectIndication(550), payloadDefectIndicationPath(560), payloadLabelMismatchPath(570), signalLabelMismatchFailurePayloadLabelMismatchVT(580), unequippedPath(590), signalLabelMismatchFailureUnequippedVT(600), lossOfSynchronization(610), outOfSynchronization(620), primarySynchronizationReferenceFailure(630), secondarySynchronizationReferenceFailure(640), thirdSynchronizationReferenceFailure(650), fourthSynchronizationReferenceFailure(660), fifthSynchronizationReferenceFailure(670), sixthSynchronizationReferenceFailure(680), failedToReceiveSynchronizationStatusMessage(690), synchronizationStatusMessagesAreDisabledOnThisInterface(700), stratum1PrimaryReferenceSourceTraceable(710), synchronizedTraceabilityUnknown(720), stratum2Traceable(730), transitNodeClockTraceable(740), stratum3ETraceable(750), stratum3Traceable(760), sonetMinimumClockTraceable(770), stratum4Traceable(780), doNotUseForSynchronization(790), reservedForNetworkSynchronizationUse(800), outgoingFailureCondition(810), remoteDefectIndicationLine(820), remoteDefectIndicationPath(830), freeRunningSynchronizationMode(840), holdoverSynchronizationMode(850), fastStartSynchronizationMode(860), internalFault(870), internalError(880), internalMessageError(890), mismatchOfEquipmentAndAttributes(900), watchdogTimerTimeout(910), softwareFaultOrFailure(920), softwareFaultDataIntegrityFault(930), programFailure(940), controlEquipmentFailure(950), primaryNonVolatileBackupMemoryFailure(960), secondaryNonVolatileBackupMemoryFailure(970), controlBusFailure(980), controlBus1Failure(990), controlBus2Failure(1000), tccAToShelfSlot1DROP1CommunicationFailure(1010), tccAToShelfSlot2DROP2CommunicationFailure(1020), tccAToShelfSlot3DROP3CommunicationFailure(1030), tccAToShelfSlot4DROP4CommunicationFailure(1040), tccAToShelfSlot5TRUNK1CommunicationFailure(1050), tccAToShelfSlot6TRUNK2CommunicationFailure(1060), tccAToShelfSlot7TCCACommunicationFailure(1070), tccAToShelfSlot8XCONACommunicationFailure(1080), tccAToShelfSlot9AICCommunicationFailure(1090), tccAToShelfSlot10XCONBCommunicationFailure(1100), tccAToShelfSlot11TCCBCommunicationFailure(1110), tccAToShelfSlot12TRUNK3CommunicationFailure(1120), tccAToShelfSlot13TRUNK4CommunicationFailure(1130), tccAToShelfSlot14DROP5CommunicationFailure(1140), tccAToShelfSlot15DROP6CommunicationFailure(1150), tccAToShelfSlot16DROP7CommunicationFailure(1160), tccAToShelfSlot17DROP8CommunicationFailure(1170), tccAToDCCAProcessorCommunicationFailure(1180), tccBToShelfSlot1DROP1CommunicationFailure(1190), tccBToShelfSlot2DROP2CommunicationFailure(1200), tccBToShelfSlot3DROP3CommunicationFailure(1210), tccBToShelfSlot4DROP4CommunicationFailure(1220), tccBToShelfSlot5TRUNK1CommunicationFailure(1230), tccBToShelfSlot6TRUNK2CommunicationFailure(1240), tccBToShelfSlot7TCCACommunicationFailure(1250), tccBToShelfSlot8XCONACommunicationFailure(1260), tccBToShelfSlot9AICCommunicationFailure(1270), tccBToShelfSlot10XCONBCommunicationFailure(1280), tccBToShelfSlot11TCCBCommunicationFailure(1290), tccBToShelfSlot12TRUNK3CommunicationFailure(1300), tccBToShelfSlot13TRUNK4CommunicationFailure(1310), tccBToShelfSlot14DROP5CommunicationFailure(1320), tccBToShelfSlot15DROP6CommunicationFailure(1330), tccBToShelfSlot16DROP7CommunicationFailure(1340), tccBToShelfSlot17DROP8CommunicationFailure(1350), tccBToDCCBProcessorCommunicationFailure(1360), controlEquipmentControlCommunicationsEquipmentFailure(1370), controlProcessorFailure(1380), workingMemoryFailure(1390), interconnectionEquipmentFailure(1400), payloadBusFailureToIOSlot1XCONSlot8(1410), payloadBusFailureToIOSlot2XCONSlot8(1420), payloadBusFailureToIOSlot3XCONSlot8(1430), payloadBusFailureToIOSlot4XCONSlot8(1440), payloadBusFailureToIOSlot5XCONSlot8(1450), payloadBusFailureToIOSlot6XCONSlot8(1460), payloadBusFailureToIOSlot12XCONSlot8(1470), payloadBusFailureToIOSlot13XCONSlot8(1480), payloadBusFailureToIOSlot14XCONSlot8(1490), payloadBusFailureToIOSlot15XCONSlot8(1500), payloadBusFailureToIOSlot16XCONSlot8(1510), payloadBusFailureToIOSlot17XCONSlot8(1520), payloadBusFailureToIOSlot1XCONSlot10(1530), payloadBusFailureToIOSlot2XCONSlot10(1540), payloadBusFailureToIOSlot3XCONSlot10(1550), payloadBusFailureToIOSlot4XCONSlot10(1560), payloadBusFailureToIOSlot5XCONSlot10(1570), payloadBusFailureToIOSlot6XCONSlot10(1580), payloadBusFailureToIOSlot12XCONSlot10(1590), payloadBusFailureToIOSlot13XCONSlot10(1600), payloadBusFailureToIOSlot14XCONSlot10(1610), payloadBusFailureToIOSlot15XCONSlot10(1620), payloadBusFailureToIOSlot16XCONSlot10(1630), payloadBusFailureToIOSlot17XCONSlot10(1640), timeSlotInterchangeEquipmentFailure(1650), equipmentFailure(1660), highTemperature(1670), invalidMACAddress(1680), boardFailure(1690), diagnosticFailure(1700), mediumAccessControlFailure(1710), facilityTerminationEquipmentFailure(1720), automaticLaserShutoffDueToHighTemperature(1730), failureToReleaseFromProtection(1740), receiverFailure(1750), transmitFailure(1760), facilityTerminationEquipmentReceiverMissing(1770), facilityTerminationEquipmentTransmitterMissing(1780), failureToSwitchToProtection(1790), failureToSwitchToProtectionRing(1800), failureToSwitchToProtectionSpan(1810), failureToSwitchToProtectionPath(1820), fanFailure(1830), equipmentUnitPlugIn(1840), nePowerFailureAtConnector(1850), fuseAlarm(1860), synchronizationUnitFailure(1870), synchronizationSwitchingEquipmentFailure(1880), equipmentUnitUnplugged(1890), loopback(1900), ds1LoopbackDueToFEACCommand(1910), loopbackCommandSentToFarEndDS1(1920), ds3LoopbackDueToFEACCommand(1930), ds3LoopbackCommandSentToFarEnd(1940), ds2LoopbackDueToFarEndCommand(1950), ds2LoopbackCommandSentToFarEnd(1960), facilityLoopback(1970), networkLoopback(1980), terminalLoopback(1990), manuallyCausedAbnormalCondition(2000), ethernetBridgeIsNewRootOfSpanningTree(2010), ethernetBridgeTopologyChange(2020), normalCondition(2030), embeddedOperationsChannelFailureLinkDown(2040), peerStateMismatch(2050), proceduralError(2060), improperRemoval(2070), duplicateNodeID(2080), blsrOutOfSync(2090), blsrMultiNodeTableUpdateCompleted(2100), protectionUnitNotAvailable(2110), performanceMonitorThresholdCrossingAlert(2120), protectionSwitch(2130), recoveryOrServiceProtectionActionHasBeenInitiated(2140), automaticSystemReset(2150), automaticUPSRSwitchCausedByAIS(2160), automaticUPSRSwitchCausedByLOP(2170), automaticUPSRSwitchCausedByUNEQ(2180), automaticUPSRSwitchCausedByPDI(2190), automaticUPSRSwitchCausedBySFBER(2200), automaticUPSRSwitchCausedBySDBER(2210), coldRestart(2220), forcedSwitchBackToWorking(2230), forcedSwitchBackToWorkingRing(2240), forcedSwitchBackToWorkingSpan(2250), forcedSwitchToProtection(2260), forcedSwitchToProtectionRing(2270), forcedSwitchToProtectionSpan(2280), workingFacilityOrEquipmentForcedToSwitchToProtectionPath(2290), initializationInitiated(2300), lockoutOfProtection(2310), lockoutOfProtectionRing(2320), lockoutOfProtectionSpan(2330), lockoutOfProtectionPath(2340), lockoutOfWorking(2350), lockoutOfWorkingRing(2360), lockoutOfWorkingSpan(2370), manualSystemReset(2380), manualSwitchToInternalClock(2390), manualSwitchToPrimaryReference(2400), manualSwitchToSecondReference(2410), manualSwitchToThirdReference(2420), manualSwitchToFourthReference(2430), manualSwitchToFifthReference(2440), manualSwitchToSixthReference(2450), manualSwitchBackToWorking(2460), manualSwitchBackToWorkingRing(2470), manualSwitchBackToWorkingSpan(2480), manualSwitchToProtection(2490), manualSwitchToProtectionRing(2500), manualSwitchToProtectionSpan(2510), manualSwitchOfWorkingFacilityOrEquipmentToProtectionPath(2520), powerfailRestart(2530), ringIsSquelchingTraffic(2540), softwareDownloadInProgress(2550), switchToInternalClock(2560), switchToPrimaryReference(2570), switchToSecondReference(2580), switchToThirdReference(2590), switchToFourthReference(2600), switchToFifthReference(2610), switchToSixthReference(2620), systemReboot(2630), switchedBackToWorking(2640), switchedToProtection(2650), warmRestart(2660), ringIsInWaitToRestoreState(2670), manualSwitchRequest(2680), forcedSwitchRequest(2690), lockoutSwitchRequest(2700), rmonHistoriesAndAlarmsResetReboot(2710), rmonThresholdCrossingAlarm(2720), alarmsSuppressedByUserCommand(2730), alarmsSuppressedForMaintenance(2740), switchingMatrixModuleFailure(2750), lanConnectionPolarityReversed(2760), autonomousPMReportMessageInhibited(2780), ioSlotToXCONCommunicationFailure(2790), stsPathTraceIdentifierMismatch(2800), nePowerFailureAtConnectorA(2810), nePowerFailureAtConnectorB(2820), freeMemoryOnCardVeryLow(2830), freeMemoryOnCardNearZero(2840), exerciseRequestOnRing(2850), exerciseRequestOnSpan(2860), squelchingPath(2870), extraTrafficPreempted(2880), farEndLockoutOfWorkingRing(2890), farEndLockoutOfWorkingSpan(2900), farEndLockoutOfProtectionRing(2910), farEndLockoutOfProtectionAllSpans(2920), farEndWorkingFacilityForcedToSwitchToProtectionRing(2930), farEndWorkingFacilityForcedToSwitchToProtectionSpan(2940), farEndManualSwitchOfWorkingFacilityToProtectionRing(2950), farEndManualSwitchOfWorkingFacilityToProtectionSpan(2960), farEndExercisingRing(2970), farEndExercisingSpan(2980), farEndBERThresholdPassedForSignalFailureRing(2990), farEndBERThresholdPassedForSignalFailureSpan(3000), farEndBERThresholdPassedForSignalDegradeRing(3010), farEndBERThresholdPassedForSignalDegradeSpan(3020), apsChannelFarEndProtectionLineSignalDegrade(3030), ringSwitchIsActiveOnTheEastSide(3040), ringSwitchIsActiveOnTheWestSide(3050), spanSwitchIsActiveOnTheEastSide(3060), spanSwitchIsActiveOnTheWestSide(3070), uniDirectionalFullPassThroughIsActive(3080), biDirectionalFullPassThroughIsActive(3090), kBytesPassThroughIsActive(3100), ringIsSegmented(3110), ringTopologyIsUnderConstruction(3120), lockoutOfProtectionAllSpans(3130), farEndOfFiberIsProvisionedWithDifferentRingID(3140), bothEndsOfFiberProvisionedAsEastOrBothAsWest(3150), securityInvalidLoginUsernameSeeAuditTrail(3160), autonomousMessagesInhibited(3170), trafficStormOnLANLANTemporarilyDisabled(3180), reptdbchgMessagesInhibited(3190), securityUserIDHasExpired(3200), partialFanFailure(3210), forcedSwitchRequestOnRing(3220), forcedSwitchRequestOnSpan(3230), lockoutSwitchRequestOnRing(3240), lockoutSwitchRequestOnSpan(3250), manualSwitchRequestOnRing(3260), manualSwitchRequestOnSpan(3270), communicationFailurePeerToPeerSlotControlBusA(3280), communicationFailurePeerToPeerSlotControlBusB(3290), controllerAToShelfSlotCommunicationFailure(3300), controllerBToShelfSlotCommunicationFailure(3310), interconnectionEquipmentFailureWorkingPayloadBus(3320), interconnectionEquipmentFailureProtectPayloadBus(3330), inhibitSwitchToProtectRequestOnEquipment(3340), inhibitSwitchToWorkingRequestOnEquipment(3350), berThresholdExceededForSignalDegradeLine(3360), berThresholdExceededForSignalDegradePath(3370), berThresholdExceededForSignalFailureLine(3380), berThresholdExceededForSignalFailurePath(3390), exercisingRingSuccessfully(3400), exercisingSpanSuccessfully(3410), spanIsInWaitToRestoreState(3420), exerciseRequestOnRingFailed(3430), exerciseRequestOnSpanFailed(3440), farEndLockoutOfProtectionSpan(3450), manufacturingDataMemoryEEPROMFailure(3460), replaceableEquipmentOrUnitIsMissing(3470), softwareDownloadFailed(3480), extraTrafficPCADropped(3490), etherTxOversubscribed(3500), etherRxOverSubscribed(3510), etherTxExcessFlowCtrl(3520), etherRxExcessFlowCtrl(3530), transportLayerFailure(3540), etherTxUnderrun(3550), synchronizationReferenceFrequencyOutOfBounds(3560), ntpOrSntpHostFailure(3570), peerCardNotResponding(3580), alarmsAndEventsSuppressedForThisObject(3590), ds3FrameFormatMismatch(3600), waitToRestore(3610), extremeHighVoltBatteryA(3620), extremeLowVoltBatteryA(3630), extremeHighVoltBatteryB(3640), extremeLowVoltBatteryB(3650), iosConfigCopyFailed(3660), iosConfigCopyInProgress(3670), iosConfigCopySuccess(3680), signalingUnableToSetupCircuit(3710), errorInStartupConfig(3712), noStartupConfig(3714), needToSaveRunningConfig(3716), invalidAlarm(3718), rsvpHelloFSMToNeighborDown(3720), securityInvalidLoginUsername(3722), databaseBackupFailed(3724), databaseRestoreFailed(3726), lmpHelloFSMToControlChannelDown(3730), lmpNeighborDiscoveryHasFailed(3740), unauthorizedIncomingSignalingRequest(3750), auditLog80PercentFull(3760), moduleCommunicationFailure(3762), auditLog100PercentFullOldestRecordsWillBeLost(3764), standbyDatabaseOutOfSync(3766), redundantPowerCapabilityLost(3768), forcedSwitchToPrimaryReference(3770), forcedSwitchToSecondReference(3780), forcedSwitchToThirdReference(3790), forcedSwitchToInternalClock(3800), industrialHighTemperature(3805), timSectionTraceIdentifierMismatchFailure(4000), aisMultiplexSectionAlarmIndicationSignal(4010), rdiMultiplexSectionRemoteDefectOrAlarmIndication(4020), timHighOrderTraceIdentifierMismatchFailure(4030), aisAdministrationUnitAlarmIndicationSignal(4040), lopAdministrationUnitLossOfPointer(4050), slmfUnequippedHighOrderPathUnequipped(4060), slmfPLMHighOrderPathLabelMismatch(4070), rdiHighOrderRemoteDefectOrAlarmIndication(4080), lopTributaryUnitLossOfPointer(4090), aisTributaryUnitAlarmIndicationSignal(4100), slmfUnequippedLowOrderPathUnequipped(4110), slmfPLMLowOrderPathLabelMismatch(4120), timLowOrderTraceIdentifierMismatchFailure(4130), rfiLowOrderRemoteFailureOrAlarmIndication(4140), g811PrimaryReferenceClockTraceable(4150), g812TransitNodeClockTraceable(4160), g812LocalNodeClockTraceable(4170), g813SynchronousEquipmentTimingSourceTraceable(4180), e1LoopbackDueToFEACCommand(4190), e1LoopbackCommandSentToFarEnd(4200), e3LoopbackDueToFEACCommand(4210), farEndMultipleE1LOSDetectedOnE3(4220), farEndE1EqptFailNonServiceAffecting(4230), farEndE1EqptFailServiceAffecting(4240), farEndSingleE1LOS(4250), farEndE3EqptFailServiceAffecting(4260), e3LoopbackCommandSentToFarEnd(4270), farEndE3EqptFailNonServiceAffecting(4280), lowVoltBatteryA(4290), highVoltBatteryA(4300), lowVoltBatteryB(4310), highVoltBatteryB(4320), msspRingOutOfSync(4330), msspMultiNodeTableUpdateCompleted(4340), automaticSNCPSwitchCausedByAIS(4350), automaticSNCPSwitchCausedByLOP(4360), automaticSNCPSwitchCausedByUNEQ(4370), automaticSNCPSwitchCausedByPDI(4380), automaticSNCPSwitchCausedBySFBER(4390), automaticSNCPSwitchCausedBySDBER(4400), stmConcatenationError(4410), e3IdleCondition(4420), channelMSSPInconsistentAPSCode(4430), channelMSSPImproperAPSCodeAPS(4440), channelMSSPNodeIdMismatchAPS(4450), channelMSSPDefaultKAPS(4460), channelMSSPConnectionLossAPS(4470), minimumClockTraceableSDH(4480), lineIsInWaitToRestoreStateSDH(4490), berThresholdExceededForSignalDegradeHighOrder(4500), berThresholdExceededForSignalFailureHighOrder(4510), berThresholdExceededForSignalDegradeLowOrder(4520), berThresholdExceededForSignalFailureLowOrder(4530), failureToSwitchToProtectionHighOrderPath(4540), failureToSwitchToProtectionLowOrderPath(4550), lofAdministrationUnitLossOfMultiFrame(4560), sdhSpanIsInWaitToRestoreState(4570), a8b10bOutOfSync(4755), odukPMAlarmIndicationSignal(4760), otukAlarmIndicationSignal(4765), otukSMBackwardDefectIndication(4770), fecUncorrectedWord(4780), gccTerminationFailure(4785), otukIncomingAlignmentError(4790), odukLockedDefectPM(4795), lossOfMultiFrame(4800), odukOpenConnectionIndication(4805), payloadTypeIdentifierMismatch(4810), odukTrailTraceIdentifierMismatch(4815), otukTrailTraceIdentifierMismatch(4820), equipmentHighLaserBias(4825), equipmentHighLaserTemp(4830), equipmentHighLaserPeltier(4835), facilityHighRxPower(4840), equipmentHighTxPower(4845), equipmentHighTransceiverVoltage(4850), equipmentLowLaserBias(4855), equipmentLowLaserTemp(4860), equipmentLowLaserPeltier(4865), facilityLowRxPower(4870), equipmentLowTxPower(4875), equipmentLowTransceiverVoltage(4880), equipmentRxLocked(4885), equipmentSquelched(4890), equipmentTxLocked(4895), otukSignalFailure(4900), odukSignalFailure(4905), otukSignalDegrade(4910), odukSignalDegrade(4915), pluggablePortMissing(4920), pluggablePortRateMismatch(4925), pluggablePortSecurityCodeMismatch(4930), tciNotSelected(4935), tci1ClockFailure(4940), odukPMBackwardDefectIndication(4945), odukTCM1BackwardDefectIndication(4950), odukTCM2BackwardDefectIndication(4955), equipmentHighRxTemperature(4960), equipmentLowRxTemperature(4965), tci2ClockFailure(4970), equipmentWavelengthMismatch(4975), dspCommunicationFailure(4980), dspFailure(4985), laserApproachingEndOfLife(5000), crossconnectLoopback(5010), adminLogoutOfUser(5020), userLockedOut(5030), adminLockoutOfUser(5040), adminLockoutClear(5050), invalidLoginUsername(5060), securityInvalidLoginPassword(5070), securityInvalidLoginLockedOut(5080), securityInvalidLoginAlreadyLoggedOn(5090), loginOfUser(5100), automaticLogoutOfIdleUser(5110), logoutOfUser(5120), enhancedRemoteFailureIndicationPathServer(5200), enhancedRemoteFailureIndicationPathConnectivity(5210), enhancedRemoteFailureIndicationPathPayload(5220), firewallHasBeenDisabled(5230), securityIntrusionDetPwd(5240), securityIntrusionDetUser(5250), connectionEquipmentMismatch(5260), disableInactiveUser(5270), disableInactiveClear(5280), batteryFailure(5290), extremeHighVolt(5300), extremeLowVolt(5310), highVolt(5320), lowVolt(5330), suspendUser(5340), suspendUserClear(5350), lineDccTerminationFailure(5360), multiplexSectionDccTerminationFailure(5370), gigaBitEthernetOutOfSync(5380), sequenceMismatch(5390), lossOfAlignment(5400), outOfUseByAdministrativeCommand(5410), outOfUseTransportFailure(5420), vcatGroupDown(5430), vcatGroupDegraded(5440), vcatGroupIncomplete(5450), alarmIndicationSignalInTX(5460), remoteAlarmIndicationInTX(5470), kByteAPSChannelFailure(5480), apsInvalidMode(5490), ipAddressAlreadyInUseWithinTheSameDccArea(5500), nodeNameInUseWithinTheSameDccArea(5510), rearPanelEthernetLinkRemoved(5520), manualSwitchToProtectResultedInNoTrafficSwitch(5530), manualSwitchBackToWorkingResultedInNoTrafficSwitch(5540), forcedSwitchToProtectResultedInNoTrafficSwitch(5550), forcedSwitchBackToWorkingResultedInNoTrafficSwitch(5560), duplicateSerialNumberDetectedOnAPluggableEntity(5570), lossOfSignalForOpticalChannel(5600), encapsulationMismatchPath(5610), encapsulationMismatchVT(5620), encapsulationMismatchHighOrderPath(5630), encapsulationMismatchLowOrderPath(5640), gfpUserPayloadMismatch(5650), gfpFibreChannelDistanceExtensionMismatch(5660), gfpFibreChannelDistanceExtensionBufferStarvation(5670), gfpFibreChannelDistanceExtensionCreditStarvation(5680), automaticWdmAnsFinished(5690), gfpClientSignalFailDetected(5700), gfpLossOfFrameDelineation(5710), gfpExtensionHeaderMismatch(5730), incomingOverheadSignalAbsent(5740), opticalSafetyRemoteInterlockOn(5750), automaticPowerControlCorrectionSkipped(5770), apcCannotSetValueDueToRangeLimits(5780), lcasVcgMemberTxSideInAddState(5790), farEndManualSwitchBackToWorkingSpan(5800), farEndForcedSwitchBackToWorkingSpan(5810), universalTransponderModuleHardwareFailure(5820), universalTransponderModuleCommunicationFailure(5830), pluginModuleRangeSettingsMismatch(5840), lcasVcgMemberTxSideInDnuState(5850), lcasControlWordCrcCheckFailure(5860), lcasVcgMemberRxSideInFailState(5870), signalLossOnDataInterface(5880), synchronizationLossOnDataInterface(5890), portFAIL(5900), unreachablePortTargetPower(5910), portAddPowerDegradeLow(5920), portAddPowerDegradeHigh(5930), portAddPowerFailLow(5940), portAddPowerFailHigh(5950), automaticPowerControlTerminatedOnManualRequest(6000), oduk1AlarmIndicationSignal(6010), oduk2AlarmIndicationSignal(6020), oduk3AlarmIndicationSignal(6030), oduk4AlarmIndicationSignal(6040), temperatureReadingMismatchBetweenSCCards(6050), voltageReadingMismatchBetweenSCCards(6060), alarmsSuppressedonOutOfGroupVcatMember(6070), blsrSoftwareVersionMismatch(6080), optimized1Plus1ApsPrimaryFacility(6090), optimized1Plus1ApsPrimarySectionMismatch(6100), optimized1Plus1ApsInvalidPrimarySection(6110), compositeClockHighLineVoltage(6120), berThresholdExceededForSignalDegradeVt(6130), berThresholdExceededForSignalFailureVt(6140), spanLengthOutOfRange(6150), idleSignalCondition(6170), idleSignalConditionInTx(6180), vtPathTraceIdentifierMismatch(6190), lossOfFrameInTX(6200), provisioningMismatch(6210), sectionTraceIdentifierMismatch(6220), regeneratorSectionTraceIdentifierMismatch(6230), switchingMatrixModuleFailureWorking(6240), switchingMatrixModuleFailureProtect(6250), slotCommunicationDisabled(6260), sessionTimeLimitExpired(6270), userPasswordChangeRequired(6280), isisAdjacencyFailure(6290), msspSoftwareVersionMismatch(6300), remoteAuthenticationFailSeeAuditLog(6310), ringIsSquelchingStsTraffic(6330), ringIsSquelchingVtTraffic(6340), archiveOfAuditLogFailed(6350), rprWrapped(6360), shelfCommunicationFailure(6370), duplicatedShelfIdentifier(6380), softwareMismatch(6390), lmpFailure(6400), opticalTerminationIncomplete(6410), forwardDefectIndication(6420), payloadMissingIndication(6430), spanMeasurementCannotBePerformed(6440), ringIsSquelchingHighOrderTraffic(6450), ringIsSquelchingLowOrderTraffic(6460), badPacketCountExceedsThreshold(6470), linkLayerKeepAliveFailure(6480), autonegotiationRemoteFailureIndication(6490), trailSignalFail(6500), ds1LoopbackCommandSentToFarEnd(6510), multiplexSectionSignalDegraded(6520), multiplexSectionExcessiveErrors(6530), highOrderPathSignalDegraded(6540), highOrderPathExcessiveErrors(6550), lowOrderPathSignalDegraded(6560), lowOrderPathExcessiveErrors(6570), regeneratorSectionDccTerminationFailure(6580), networkMemoryPoolLow(6590), ospfRoutingTableOverflow(6600), autoLaserShutdownDisabled(6610), rprProtectionIsActive(6630), maxRPRStationNumberExceeded(6640), rprProtectionConfigurationMismatched(6650), reservedBandwidthLinkRateExceededOnRinglet0(6660), reservedBandwidthLinkRateExceededOnRinglet1(6670), rprInterfaceInPassThroughMode(6680), rprPeerNodeIsMissing(6690), rprRiFailure(6700), rprSignalFailure(6710), rprSignalDegrade(6720), interlinkFailure(6730), apcWrongGain(6740), rprSpanMismatch(6750), efmRemoteFaultIndicationCriticalEvent(6760), efmRemoteFaultIndicationDyingGasp(6770), efmRemoteFaultIndicationLinkFault(6780), efmLinkMonitoringErroredSymbolPeriodEvent(6790), efmLinkMonitoringErroredFrameEvent(6800), efmLinkMonitoringErroredFramePeriodEvent(6810), efmLinkMonitoringErroredFrameSecondsSummary(6820), efmRemoteLoopbackRequestFailed(6830), fastAutomaticProtectionSwitching(6840), fastAutomaticProtectionSwitchingConfigMismatch(6850), lcasSinkGroupError(6860), lcasVcgMemberRxSideInDnuState(6870), fcDistanceExtFuncNotEstablished(6880), nonCiscoPPMInserted(6890), unqualifiedPPMInserted(6900), ftaMismatch(6910), cardPortsUnableToProvideProtection(6920), lmpSignalDegrade(6930), lmpSignalFailure(6940), lmpUnallocatedDataLink(6950), frontPortLinkLoss(6960), bertEnbl(6970), bertSyncFail(6975), workQueueFull(6980), equipmentPowerFailureAtConnectorA(7000), equipmentPowerFailureAtConnectorB(7005), equipmentPowerFailureAtReturnConnectorA(7010), equipmentPowerFailureAtReturnConnectorB(7015), bridgeAndRollHasOccurred(7055), bridgeAndRollIsPendingAValidSignal(7060), clockBusFailureTscA(7160), clockBusFailureTscB(7165), ospfHelloFail(7185), openIOSlots(7200), lossOfClockFromMateShelfController(7210), virtualLanAlarmIndiacationSignal(7225), dcuLossFailure(7230), ochncMaintenance(7235), ramanLaserShutdown(7240), losOfRamanSignal(7245), mcastMacTableFull(7250), multicastMacAddressAliasing(7255), ramanPwrProtOn(7260), cppPeerNotResponding(7265), voaControlLoopDisableDueToExcessiveCounterPropagationLight(7275), wizardIsRunning(7280), ramanGainNotReached(7285), pprForwardDefectIndication(7295), pprBackwardDefectIndication(7300), pprCoordinatedMaintenance(7305), pprTriggerThresholdBerExceeded(7310), localFault(7315), remoteFault(7320), efmRemoteLoopbackConfigured(7325), efmPeerMissing(7330), eqptDegrade(7335), excessiveBackPropagation(7340), remoteMaintenanceEndPointIsDown(7345), crossConnectedCFMService(7350), cfmLoop(7355), cfmConfigurationError(7360), outOfChannelGroupBundle(7365), repNeighborAdjacencyFailure(7370), repLinkFlapping(7375), faultInREPSegment(7380), primaryREPEdgePortElected(7385), secondaryREPEdgePortElected(7390), stcnREPGenerated(7395), vlbREPActivated(7400), vlbREPTriggerSoakingDelayActive(7405), wanSyncloss(7410), laserShutdownDueToWavelengthDrift(7415), manualLaserRestart(7420), laserShutdownDueToNonCiscoPPMInserted(7425), ethernetOSCTerminationFailure(7430), softwareSignatureVerificationFailed(7445), protectVolumeSoftwareSignatureVerificationFailed(7450), activeVolumeSoftwareSignatureVerificationFailed(7455), peerPortClientSignalFailDetected(7460), channelShutdownDueToWavelengthDrift(7465), usbWriteFailure(7475), usbSyncInProgress(7480), autoSensingUnableToDetectValidPayload(7485), payloadAutoSensingInProgress(7490), gfpClientSignalFailDetectedDueToSigloss(7495), gfpClientSignalFailDetectedDueToSyncloss(7500), pmdDegrade(7510), standbyTccNEClockIsInternalClock(7515), chromaticDispersionValue(7520), packetTransportServiceFailed(7525), satellitePanelDiscoveryFailure(7530), satellitePanelActiveLinkFailure(7535), satellitePanelCommunicationFailure(7540), satellitePanelImproperConfiguration(7545), satellitePanelFanMismatchOfEquipmentAndAttributes(7550), satellitePanelFanFailure(7555), satellitePanelPartialFanFailure(7560), satellitePanelFANManufacturingDataMemoryEEPROMFailure(7565), satellitePanelFANUnitIsMissing(7570), satellitePanelIndustrialHighTemperature(7575), satellitePanelHighTemperature(7580), satellitePanelBatteryFailureA(7585), plannedSwitchOver(7590), protectionCardConfigurationMismatch(7595), routerProcessorSwitchOver(7600), runningLowOnResources(7605), noMoreResourcesAreAvailable(7610), esmcFailure(7615), licenseWillExpireWithin24Hours(7620), licenseWillExpireAnytimeAfter1DayButBefore14Days(7625), licenseIsExpired(7630), licenseCountViolation(7635), temporaryLicenseIsInUse(7640), evaluationLicenseIsInUse(7645), licenseIsMissing(7650), pseudowireDown(7655), workingPseudowireControlPlaneDown(7660), protectPseudowireControlPlaneDown(7665), workingPseudowireConnectivityCheckDown(7670), protectPseudowireConnectivityCheckDown(7675), pseudowireTrafficSwitchedToProtection(7680), workingPseudowireLocalAcTxPortFault(7685), protectPseudowireLocalAcTxPortFault(7690), workingPseudowireLocalAcRxPortFault(7695), protectPseudowireLocalAcRxPortFault(7700), workingPseudowireRemoteAcTxPortFault(7705), protectPseudowireRemoteAcTxPortFault(7710), workingPseudowireRemoteAcRxPortFault(7715), protectPseudowireRemoteAcRxPortFault(7720), slaThresholdCrossAlert(7725), protectLocalPseudowireNotForwarding(7730), workingPseudowireNotForwarding(7735), protectPseudowireNotForwarding(7740), tpTunnelDown(7745), workingLabelSwitchedPathDown(7750), protectLabelSwitchedPathDown(7755), workingLabelSwitchedPathAlarmIndicationSignal(7760), protectLabelSwitchedPathAlarmIndicationSignal(7765), workingLabelSwitchedPathRemoteDefectIndication(7770), protectLabelSwitchedPathRemoteDefectIndication(7775), bidirectionalForwardDetectionDown(7780), tpTrafficSwitchedFromWorkingToProtection(7785), workingTpLockout(7790), protectTpLockout(7795), ethernetFlowPointFailed(7800), teTunnelDown(7805), macSystemLimitReached(7810), macBridgeDomainLimitReached(7815), autoSensingDisabled(7820), smBackwardIncomingAlignmentError(7825), resourceAllocationFailed(7830), lossOfDFBSignal(7835), workingLabelSwitchedPathLinkDownIndication(7840), protectLabelSwitchedPathLinkDownIndication(7845), workingLabelSwitchedPathLockReport(7850), protectLabelSwitchedPathLockReport(7855), satellitePanelBatteryFailureB(7860), highBitErrorRate(7865), backPanelFacilityLoopback(7870), backPanelTerminalLoopback(7875), trunkPayloadTypeMismatch(7880), invalidMuxponderConfiguration(7885), coolingProfileMismatch(7890), trunkOduAlarmIndicationSignal(7895), companionCardMissing(7900), controlPlaneUnverifiedClearedAlarmsPresent(7905), powerConsumptionLimitHasCrossed(7910), masterKeyExchangeFailed(7915), unitHighTemperature(7930), overTemperatureUnitProtected(7935), seqMismatchCount(7945), keyProgramOnAlteraFpgaFailed(7960), duplicateNodeControllerDetected(7970), restorationInProg(7975), ramanPumpsCalibrationProcedureIsRunning(7980), ramanPumpsCalibrationIsScheduledToRunInTheNextMinutes(7985), odukTCM1AlarmIndicationSignal(13100), odukTCM2AlarmIndicationSignal(13105), odukLockedDefectTCM1(13110), odukLockedDefectTCM2(13115), otukLossOfFrame(13120), odukOpenConnectionIndicationTCM1(13125), odukOpenConnectionIndicationTCM2(13130), odukTrailTraceIdentifierMismatchTCM1(13135), odukTrailTraceIdentifierMismatchTCM2(13140), odukSignalFailureTCM1(13145), odukSignalFailureTCM2(13150), odukSignalDegradeTCM1(13155), odukSignalDegradeTCM2(13160), lossOfChannel(13165), fecMismatch(13170), timSectionMonitorTraceIdentifierMismatchFailure(13175), automaticLaserShutdown(13180), shutterInsertionLossVariationDegradeLow(13200), opticalChannelDeactivationFailure(13205), shutterInsertionLossVariationDegradeHigh(13210), networkTopologyIncomplete(13215), pluginModuleCommunicationFailure(13220), opticalNetworkTypeMismatch(13225), opticalPowerDegradeLow(13230), automaticPowerControlFailure(13235), opticalPowerDegradeHigh(13240), automaticPowerControlDisabled(13245), opticalPowerFailureLow(13250), ringIdMismatch(13255), opticalPowerFailureHigh(13260), lossOfContinuity(13270), variableOpticalAttenuatorDegradeLow(13280), variableOpticalAttenuatorDegradeHigh(13290), variableOpticalAttenuatorFailureLow(13300), variableOpticalAttenuatorFailureHigh(13310), laserBiasDegrade(13320), laserBiasFailure(13330), laserTemperatureDegrade(13340), opticalAmplifierGainDegradeLow(13350), opticalAmplifierGainDegradeHigh(13360), opticalAmplifierGainFailureLow(13370), opticalAmplifierGainFailureHigh(13380), opticalChannelConnectionFailure(13390), opticalChannelIncomplete(13395), opticalChannelActivationFailure(13400), laserAutoPowerReduction(13410), caseTemperatureDegrade(13420), fiberTemperatureDegrade(13430), shutterOpen(13440), awgTemperatureDegrade(13450), awgTemperatureFailure(13460), awgOverTemperature(13470), opticalAmplifierInitialization(13480), awgWarmUp(13490), incSigloss(13510), incSyncloss(13515), incGfpOutOfFrame(13520), incGfpSigLoss(13525), incGfpSyncLoss(13530)

Cerent454EntityClass  
TEXTUAL-CONVENTION    
  current INTEGER unknownEntity(1), ne(10), backplane(30), eqpt(50), port(60), ocn(70), stmn(71), aip(80), fanTray(90), crs(100), ds3(110), almExpPanel(120), almIfExtnsn(130), stsMon(140), vcMonHp(141), dwdmClient(150), stsTerm(160), vcTermHp(161), dwdmTrunk(170), dwdmOptics(180), psSts(190), rsms(200), xcSts(210), bits(220), dwdmFec(230), neSynchRef(240), dwdm8b10b(250), extSynchRef(260), dwdmOtn(270), envAlrm(280), envCtrl(290), neRing(360), ds1(390), vtMon(410), vcMonLp(411), vtTerm(420), vcTermLP(421), fUdc(430), msUdc(440), spareSdcc(450), ucpCircuit(480), ucpIpcc(490), ucpNeighbor(500), ec1(510), ps(520), psVt(530), e100t(540), e1000t(550), etherBridge(560), e1(600), e3(630), e4(640), stm1E(650), ds3i(660), g1000(670), ml100t(680), ml1000(690), dwdmSfp(700), dwdmScl(710), dwdmTcm1(720), dwdmTcm2(730), dwdmOcn(740), dwdmSm(750), dwdmPm(760), dwdmTcm(770), pwr(780), stsTermVcat(790), vtTermVcat(800), vcatGroup(810), fcmr(820), entOptics(830), ce100t(840), ppm(850), twor(860), isc(870), escon(880), bic(890), gfp(900), gige(910), pos(920), cap(930), dwdmData(940), logFac(950), ge(960), fc(970), ec1p1(980), mlFx(990), ochTerm(1000), shelf(1010), ce1000(1020), cemr(1030), lmp(1040), lmpControlChannel(1050), lmpTeLink(1060), lmpDataLink(1070), rpr(1080), ether(1090), mlmr(1100), otu(1110), aots(3200), ots(3210), oms(3220), och(3230), osc(3240), ochnc(3250), ib(3260), chgrp(3270), hdlc(3280), msISC(3290), ecu(3300), lcdFlash(3310), usb(3320), fe(3330), odu0(3350), odu1(3360)

Cerent454AlarmEntry  
SEQUENCE    
  cerent454AlarmIndex Integer32
  cerent454AlarmObjectType Cerent454EntityClass
  cerent454AlarmSlotNumber Integer32
  cerent454AlarmPortNumber CerentPortNumber
  cerent454AlarmLineNumber Integer32
  cerent454AlarmObjectIndex Integer32
  cerent454AlarmType Cerent454AlarmType
  cerent454AlarmState CerentNotificationClass
  cerent454AlarmTimeStamp TimeStamp
  cerent454AlarmObjectName DisplayString
  cerent454AlarmAdditionalInfo DisplayString
  cerent454AlarmSeverity CerentAlarmSeverity
  cerent454AlarmStatus CerentAlarmStatus
  cerent454AlarmServiceAffecting CerentAlarmServiceAffecting

Cerent454ReportedAlarmEntry  
SEQUENCE    
  cerent454ReportedAlarmIndex Integer32
  cerent454ReportedAlarmObjectType Cerent454EntityClass
  cerent454ReportedAlarmSlotNumber Integer32
  cerent454ReportedAlarmPortNumber CerentPortNumber
  cerent454ReportedAlarmObjectIndex Integer32
  cerent454ReportedAlarmType Cerent454AlarmType
  cerent454ReportedAlarmTimeStamp TimeStamp
  cerent454ReportedAlarmObjectName DisplayString
  cerent454ReportedAlarmAdditionalInfo DisplayString
  cerent454ReportedAlarmSeverity CerentAlarmSeverity
  cerent454ReportedAlarmStatus CerentAlarmStatus
  cerent454ReportedAlarmServiceAffecting CerentAlarmServiceAffecting

Cerent454ThresholdEntry  
SEQUENCE    
  cerent454ThresholdIndex Integer32
  cerent454ThresholdMonitorType CerentMonitorType
  cerent454ThresholdLocation CerentLocation
  cerent454ThresholdPeriod CerentPeriod
  cerent454ThresholdSetValue Integer32
  cerent454ThresholdCurrentValue Integer32
  cerent454ThresholdDetectType INTEGER

Defined Values

cerent454MibModule 1.3.6.1.4.1.3607.1.10.20
This module provides the definitions for objects for managing Cisco OTBU ONS 15454.
MODULE-IDENTITY    

cerent454Mib 1.3.6.1.4.1.3607.6.10
The is the node under which all Cisco ONS 15454 specific mib object are located.
OBJECT-IDENTITY    

cerent454Conformance 1.3.6.1.4.1.3607.6.10.10
This node is created compliance. Has objects as required by the RFCs
OBJECT-IDENTITY    

cerentCommonObjects 1.3.6.1.4.1.3607.6.10.100
The objects here are expected to be used by all Cisco OTBU Products. These will be mixed with specific objects of the product-specific branch.
OBJECT-IDENTITY    

cerentCommonEvents 1.3.6.1.4.1.3607.6.10.200
This branch is similar to cerentCommonObjects, except that this will have only events
OBJECT-IDENTITY    

cerent454Groups 1.3.6.1.4.1.3607.6.10.10.10
Tok_String
OBJECT-IDENTITY    

cerent454Compliance 1.3.6.1.4.1.3607.6.10.10.20
Tok_String
OBJECT-IDENTITY    

cerent454Objects 1.3.6.1.4.1.3607.6.10.20
The cerent454 specific objects themselves
OBJECT-IDENTITY    

cerent454CommonObjectsGroup 1.3.6.1.4.1.3607.6.10.100.10
The group to combine all the Cisco OTBU common objects
OBJECT-IDENTITY    

cerent454EnableNotification 1.3.6.1.4.1.3607.6.10.100.10.10
This variable indicates whether the system produces notifications. A value=FALSE will prevent notifications from being sent by this system.
OBJECT-TYPE    
  TruthValue  

cerent454NodeTime 1.3.6.1.4.1.3607.6.10.100.10.20
Indicates current local time as reflected by the Cisco OTBU equipment. The format this scalar is YYYYMMDDhhmmss{S/D}. E.g., 20011103133453D means 1:34:53 PM PDT on 03/Nov/2001 19990614095436S means 9:54:36 AM PST on 14/Jun/1999. If the last octet is S then the time is standard time. Otherwise it is D to indicate it is daylight saving time, if applicable
OBJECT-TYPE    
  DisplayString  

cerent454SentNotifications 1.3.6.1.4.1.3607.6.10.100.10.30
A count of v1+v2 notifications sent out by the agent. Resets to zero after cold/warm start.
OBJECT-TYPE    
  Counter32  

cerent454LastChangeTime 1.3.6.1.4.1.3607.6.10.100.10.40
The value of sysUpTime at the time a conceptual row is created or deleted in cerent454AlarmTable
OBJECT-TYPE    
  TimeStamp  

cerent454MultishelfEnabled 1.3.6.1.4.1.3607.6.10.100.10.50
This variable indicates whether the system is configured in multi-shelf mode or single-shelf mode.
OBJECT-TYPE    
  TruthValue  

cerent454GeneralGroup 1.3.6.1.4.1.3607.6.10.20.20
Tok_String
OBJECT-IDENTITY    

cerent454SoftwareVersion 1.3.6.1.4.1.3607.6.10.20.20.10
Indicates the version of software that is used in Cisco ONS 15454. E.g., 2.2.03
OBJECT-TYPE    
  DisplayString  

cerent454AlarmGroup 1.3.6.1.4.1.3607.6.10.20.30
The group that will represent all the alarm info in the Cisco ONS 15454 node
OBJECT-IDENTITY    

cerent454AlarmCount 1.3.6.1.4.1.3607.6.10.20.30.10
Total number of active alarms in Cisco ONS 15454. This equals the total number of rows in cerent454AlarmTable at any time.
OBJECT-TYPE    
  Unsigned32  

cerent454AlarmTable 1.3.6.1.4.1.3607.6.10.20.30.20
This table has all currently raised conditions for the network node. A Condition is a fault or status detected by hardware or software.
OBJECT-TYPE    
  SEQUENCE OF  
    Cerent454AlarmEntry

cerent454AlarmEntry 1.3.6.1.4.1.3607.6.10.20.30.20.1
Row definition for cerent454AlarmTable
OBJECT-TYPE    
  Cerent454AlarmEntry  

cerent454AlarmIndex 1.3.6.1.4.1.3607.6.10.20.30.20.1.10
Identifies each entry in alarm table. May not start with one and there may be some missing numbers.
OBJECT-TYPE    
  Integer32 1..2147483647  

cerent454AlarmObjectType 1.3.6.1.4.1.3607.6.10.20.30.20.1.20
This will indicate what is the type of the entity which raised this alarm. ( E.g., DS3, etherBridge, VT-TERM, etc ) The NMS is expected to use this value to decide which table to poll for further info about the alarm
OBJECT-TYPE    
  Cerent454EntityClass  

cerent454AlarmSlotNumber 1.3.6.1.4.1.3607.6.10.20.30.20.1.30
This will indicate what is the slot of the object which raised this alarm. If not relevant to the alarm, will be zero.
OBJECT-TYPE    
  Integer32  

cerent454AlarmPortNumber 1.3.6.1.4.1.3607.6.10.20.30.20.1.40
This will indicate what is the port of the object which raised this alarm.
OBJECT-TYPE    
  CerentPortNumber  

cerent454AlarmLineNumber 1.3.6.1.4.1.3607.6.10.20.30.20.1.50
This will indicate what is the port of the object which raised this alarm. If not relevant to the alarm, will be zero.
OBJECT-TYPE    
  Integer32  

cerent454AlarmObjectIndex 1.3.6.1.4.1.3607.6.10.20.30.20.1.60
Every alarm is raised by an object and this object is an entry in a specific table. This is the index of the object in that table E.g., if the alarm is interface related, this index is the index of the interface in the interface table.
OBJECT-TYPE    
  Integer32  

cerent454AlarmType 1.3.6.1.4.1.3607.6.10.20.30.20.1.70
Indicates what the exact nature of the alarm. See the Cerent454AlarmType TC for mapping details
OBJECT-TYPE    
  Cerent454AlarmType  

cerent454AlarmState 1.3.6.1.4.1.3607.6.10.20.30.20.1.80
Specifies alarm severity and service affecting status ( SA/NSA ). Only {minor|major|critical}+{NA|NSA} alarms and standing conditions will be represented here. However, this mib object is included in each trap dispatched and in the trap this object can contain all the possible values of CerentNotificationClass type.
OBJECT-TYPE    
  CerentNotificationClass  

cerent454AlarmTimeStamp 1.3.6.1.4.1.3607.6.10.20.30.20.1.90
The value of sysUpTime when this entry was created. This is accurate only upto a second.
OBJECT-TYPE    
  TimeStamp  

cerent454AlarmObjectName 1.3.6.1.4.1.3607.6.10.20.30.20.1.100
TL1-style user-visible name which uniquely identifies an object in the system
OBJECT-TYPE    
  DisplayString  

cerent454AlarmAdditionalInfo 1.3.6.1.4.1.3607.6.10.20.30.20.1.110
Additional information for the alarm object. In the current version of the MIB, this object contains the following information :- a) Provisioned description for alarms of type 'failureDetectedExternalToTheNE'. This object would be a null string if no additional information is specified.
OBJECT-TYPE    
  DisplayString  

cerent454AlarmSeverity 1.3.6.1.4.1.3607.6.10.20.30.20.1.120
Specifies severity of the alarm being sent out.
OBJECT-TYPE    
  CerentAlarmSeverity  

cerent454AlarmStatus 1.3.6.1.4.1.3607.6.10.20.30.20.1.130
Represents if the alarm is currently raised or cleared.
OBJECT-TYPE    
  CerentAlarmStatus  

cerent454AlarmServiceAffecting 1.3.6.1.4.1.3607.6.10.20.30.20.1.140
Specifies whether the alarm that is being sent out is Service Affecting (SA) or Non- Service Affecting (NSA).
OBJECT-TYPE    
  CerentAlarmServiceAffecting  

cerent454ReportedAlarmCount 1.3.6.1.4.1.3607.6.10.20.30.30
Number of alarms currently reported against Cisco ONS 15454. This equals the number of rows in cerent454ReportedAlarmTable.
OBJECT-TYPE    
  Unsigned32  

cerent454ReportedAlarmTable 1.3.6.1.4.1.3607.6.10.20.30.40
This table has the list of alarms currently reported for the Cisco ONS node. It does not include any cleared alarms. The alarms in this table are in compliance with Telcordia GR-253. This means that if a network problem causes two alarms, such a as loss of frame(LOF) and loss of signal(LOS), only LOS alarm will be in this table because it supersedes and replaces the LOF.
OBJECT-TYPE    
  SEQUENCE OF  
    Cerent454ReportedAlarmEntry

cerent454ReportedAlarmEntry 1.3.6.1.4.1.3607.6.10.20.30.40.1
Row definition for cerent454ReportedAlarmTable
OBJECT-TYPE    
  Cerent454ReportedAlarmEntry  

cerent454ReportedAlarmIndex 1.3.6.1.4.1.3607.6.10.20.30.40.1.10
Identifies each entry in ReportedAlarm table. May not start with one and there may be some missing numbers.
OBJECT-TYPE    
  Integer32 1..2147483647  

cerent454ReportedAlarmObjectType 1.3.6.1.4.1.3607.6.10.20.30.40.1.20
This will indicate the type of the entity which raised this alarm. ( E.g., DS3, etherBridge, VT-TERM, etc ) The NMS is expected to use this value to decide which table to poll for further info about the alarm
OBJECT-TYPE    
  Cerent454EntityClass  

cerent454ReportedAlarmSlotNumber 1.3.6.1.4.1.3607.6.10.20.30.40.1.30
This will indicate what is the slot of the object which raised this alarm. If not relevant to the alarm, will be zero.
OBJECT-TYPE    
  Integer32  

cerent454ReportedAlarmPortNumber 1.3.6.1.4.1.3607.6.10.20.30.40.1.40
This will indicate what is the port of the object which raised this alarm.
OBJECT-TYPE    
  CerentPortNumber  

cerent454ReportedAlarmObjectIndex 1.3.6.1.4.1.3607.6.10.20.30.40.1.50
Every alarm is raised by an object and this object is an entry in a specific table. This is the index of the object in that table E.g., if the alarm is interface related, this is the index of the interface in the interface table.
OBJECT-TYPE    
  Integer32  

cerent454ReportedAlarmType 1.3.6.1.4.1.3607.6.10.20.30.40.1.60
Indicates the exact nature of the alarm.
OBJECT-TYPE    
  Cerent454AlarmType  

cerent454ReportedAlarmTimeStamp 1.3.6.1.4.1.3607.6.10.20.30.40.1.70
The value of sysUpTime when this entry was created. This is accurate only upto a second.
OBJECT-TYPE    
  TimeStamp  

cerent454ReportedAlarmObjectName 1.3.6.1.4.1.3607.6.10.20.30.40.1.80
TL1-style user-visible name which uniquely identifies an object in the system
OBJECT-TYPE    
  DisplayString  

cerent454ReportedAlarmAdditionalInfo 1.3.6.1.4.1.3607.6.10.20.30.40.1.90
Additional information for the alarm object. In the current version of the MIB, this object contains the following information :- a) Provisioned description for alarms of type 'failureDetectedExternalToTheNE'. This object would be a null string if no additional information is specified.
OBJECT-TYPE    
  DisplayString  

cerent454ReportedAlarmSeverity 1.3.6.1.4.1.3607.6.10.20.30.40.1.100
Specifies severity of the alarm.
OBJECT-TYPE    
  CerentAlarmSeverity  

cerent454ReportedAlarmStatus 1.3.6.1.4.1.3607.6.10.20.30.40.1.110
Represents if the alarm is currently raised or cleared.
OBJECT-TYPE    
  CerentAlarmStatus  

cerent454ReportedAlarmServiceAffecting 1.3.6.1.4.1.3607.6.10.20.30.40.1.120
Specifies whether the alarm that is being sent out is Service Affecting (SA) or Non- Service Affecting (NSA).
OBJECT-TYPE    
  CerentAlarmServiceAffecting  

cerent454ThresholdGroup 1.3.6.1.4.1.3607.6.10.20.40
The group that will represent all the threshold info in the Cisco ONS 15454 node
OBJECT-IDENTITY    

cerent454ThresholdTable 1.3.6.1.4.1.3607.6.10.20.40.10
This table holds all the defined Thresholds. This table is currently unimplemented.
OBJECT-TYPE    
  SEQUENCE OF  
    Cerent454ThresholdEntry

cerent454ThresholdEntry 1.3.6.1.4.1.3607.6.10.20.40.10.1
Row definition for cerent454ThresholdTable
OBJECT-TYPE    
  Cerent454ThresholdEntry  

cerent454ThresholdIndex 1.3.6.1.4.1.3607.6.10.20.40.10.1.10
Uniquely identifies each entry in Threshold table. May not start with one and there will be some missing numbers.
OBJECT-TYPE    
  Integer32 1..2147483647  

cerent454ThresholdMonitorType 1.3.6.1.4.1.3607.6.10.20.40.10.1.20
This object indicates the type of metric monitored.
OBJECT-TYPE    
  CerentMonitorType  

cerent454ThresholdLocation 1.3.6.1.4.1.3607.6.10.20.40.10.1.30
This indicates if it near or far end
OBJECT-TYPE    
  CerentLocation  

cerent454ThresholdPeriod 1.3.6.1.4.1.3607.6.10.20.40.10.1.40
The sampling interval period is indicated here
OBJECT-TYPE    
  CerentPeriod  

cerent454ThresholdSetValue 1.3.6.1.4.1.3607.6.10.20.40.10.1.50
The value of this object will be threshold that was provisioned by the NMS
OBJECT-TYPE    
  Integer32  

cerent454ThresholdCurrentValue 1.3.6.1.4.1.3607.6.10.20.40.10.1.60
The current value of the counter which measures the metric. This column will never be implemented as the value of this object is already accessible through IETF MIBs.
OBJECT-TYPE    
  Integer32  

cerent454ThresholdDetectType 1.3.6.1.4.1.3607.6.10.20.40.10.1.70
The value of this object will be the detect type for the threshold.
OBJECT-TYPE    
  INTEGER unknown(1), none(10), mon(20), term(30)  

cerent454Events 1.3.6.1.4.1.3607.6.10.30
Place holder for all notifications of Cisco ONS 15454
OBJECT-IDENTITY    

cerent454V2Events 1.3.6.1.4.1.3607.6.10.30.0
The sub-identifier has to be zero, as part of the interoperability agreement between SNMPv1 and SNMPv2 worlds.
OBJECT-IDENTITY    

alarmUnknown 1.3.6.1.4.1.3607.6.10.30.0.1
alarm unknown
NOTIFICATION-TYPE    

alarmCutoffIsInManualMode 1.3.6.1.4.1.3607.6.10.30.0.10
alarm cutoff is in manual mode
NOTIFICATION-TYPE    

failureDetectedExternalToTheNE 1.3.6.1.4.1.3607.6.10.30.0.20
failure detected External to the NE
NOTIFICATION-TYPE    

externalError 1.3.6.1.4.1.3607.6.10.30.0.30
external error
NOTIFICATION-TYPE    

excessiveSwitching 1.3.6.1.4.1.3607.6.10.30.0.40
excessive switching
NOTIFICATION-TYPE    

sdccTerminationFailure 1.3.6.1.4.1.3607.6.10.30.0.50
SDCC Termination failure
NOTIFICATION-TYPE    

incomingFailureCondition 1.3.6.1.4.1.3607.6.10.30.0.60
incoming failure condition
NOTIFICATION-TYPE    

alarmIndicationSignal 1.3.6.1.4.1.3607.6.10.30.0.70
alarm indication signal
NOTIFICATION-TYPE    

alarmIndicationSignalLine 1.3.6.1.4.1.3607.6.10.30.0.80
alarm indication signal LINE
NOTIFICATION-TYPE    

alarmIndicationSignalPath 1.3.6.1.4.1.3607.6.10.30.0.90
alarm indication signal Path
NOTIFICATION-TYPE    

alarmIndicationSignalVT 1.3.6.1.4.1.3607.6.10.30.0.100
alarm indication signal VT
NOTIFICATION-TYPE    

apsChannelFailure 1.3.6.1.4.1.3607.6.10.30.0.110
APS Channel Failure
NOTIFICATION-TYPE    

channelByteFailureAPS 1.3.6.1.4.1.3607.6.10.30.0.120
channel Byte failure APS
NOTIFICATION-TYPE    

channelProtectionSwitchingChannelMatchFailureAPS 1.3.6.1.4.1.3607.6.10.30.0.130
channel Protection Switching Channel Match failure APS
NOTIFICATION-TYPE    

channelAutomaticProtectionSwitchModeMismatchAPS 1.3.6.1.4.1.3607.6.10.30.0.140
channel Automatic Protection Switch Mode Mismatch APS
NOTIFICATION-TYPE    

farEndProtectionLineFailure 1.3.6.1.4.1.3607.6.10.30.0.150
Far End Protection Line Failure
NOTIFICATION-TYPE    

inconsistentAPSCode 1.3.6.1.4.1.3607.6.10.30.0.160
Inconsistent APS code
NOTIFICATION-TYPE    

improperAPSCode 1.3.6.1.4.1.3607.6.10.30.0.170
Improper APS code
NOTIFICATION-TYPE    

nodeIdMismatch 1.3.6.1.4.1.3607.6.10.30.0.180
Node Id Mismatch APS
NOTIFICATION-TYPE    

channelDefaultKAPS 1.3.6.1.4.1.3607.6.10.30.0.190
channel Default K APS
NOTIFICATION-TYPE    

connectionLoss 1.3.6.1.4.1.3607.6.10.30.0.200
Connection loss APS
NOTIFICATION-TYPE    

bipolarViolation 1.3.6.1.4.1.3607.6.10.30.0.210
bipolar Violation
NOTIFICATION-TYPE    

carrierLossOnTheLAN 1.3.6.1.4.1.3607.6.10.30.0.220
carrier Loss on the LAN
NOTIFICATION-TYPE    

concatenationErrorSTS 1.3.6.1.4.1.3607.6.10.30.0.230
concatenation error STS
NOTIFICATION-TYPE    

excessCollisionsOnTheLAN 1.3.6.1.4.1.3607.6.10.30.0.240
excess collisions on the LAN
NOTIFICATION-TYPE    

facilityFailure 1.3.6.1.4.1.3607.6.10.30.0.250
Facility Failure
NOTIFICATION-TYPE    

farEndAIS 1.3.6.1.4.1.3607.6.10.30.0.260
far end AIS
NOTIFICATION-TYPE    

farEndMultipleDS1LOSDetectedOnDS3 1.3.6.1.4.1.3607.6.10.30.0.270
far end Multiple DS1 LOS detected on DS3
NOTIFICATION-TYPE    

farEndDS1EqptFailNonServiceAffecting 1.3.6.1.4.1.3607.6.10.30.0.280
far end DS1 eqpt fail non service affecting
NOTIFICATION-TYPE    

farEndDS1EqptFailServiceAffecting 1.3.6.1.4.1.3607.6.10.30.0.290
far end DS1 Eqpt fail service affecting
NOTIFICATION-TYPE    

farEndSingleDS1LOS 1.3.6.1.4.1.3607.6.10.30.0.300
far end Single DS1 LOS
NOTIFICATION-TYPE    

farEndDS3EqptFailNonServiceAffecting 1.3.6.1.4.1.3607.6.10.30.0.310
far end DS3 Eqpt failure non service affecting
NOTIFICATION-TYPE    

farEndDS3EqptFailServiceAffecting 1.3.6.1.4.1.3607.6.10.30.0.320
far end DS3 Eqpt failure service affecting
NOTIFICATION-TYPE    

farEndCommonEquipmentFailureNonServiceAffecting 1.3.6.1.4.1.3607.6.10.30.0.330
far end common Eqpt failure non service affecting
NOTIFICATION-TYPE    

farEndIDLE 1.3.6.1.4.1.3607.6.10.30.0.340
far end IDLE
NOTIFICATION-TYPE    

farEndLOS 1.3.6.1.4.1.3607.6.10.30.0.350
far end LOS
NOTIFICATION-TYPE    

farEndLOF 1.3.6.1.4.1.3607.6.10.30.0.360
far end LOF
NOTIFICATION-TYPE    

farEndBlockError 1.3.6.1.4.1.3607.6.10.30.0.370
far End Block Error
NOTIFICATION-TYPE    

ds3IdleCondition 1.3.6.1.4.1.3607.6.10.30.0.380
idle Condition DS3
NOTIFICATION-TYPE    

lossOfFrame 1.3.6.1.4.1.3607.6.10.30.0.390
loss of Frame
NOTIFICATION-TYPE    

lossOfPointer 1.3.6.1.4.1.3607.6.10.30.0.400
loss of Pointer
NOTIFICATION-TYPE    

lossOfPointerPath 1.3.6.1.4.1.3607.6.10.30.0.410
loss of Pointer Path
NOTIFICATION-TYPE    

lossOfPointerVT 1.3.6.1.4.1.3607.6.10.30.0.420
loss of Pointer VT
NOTIFICATION-TYPE    

lossOfSignal 1.3.6.1.4.1.3607.6.10.30.0.430
loss of Signal
NOTIFICATION-TYPE    

outOfFrame 1.3.6.1.4.1.3607.6.10.30.0.440
out of Frame
NOTIFICATION-TYPE    

pathSelectorFailure 1.3.6.1.4.1.3607.6.10.30.0.450
Path Selector Failure
NOTIFICATION-TYPE    

remoteAlarmIndication 1.3.6.1.4.1.3607.6.10.30.0.460
remote Alarm Indication
NOTIFICATION-TYPE    

remoteFailureIndication 1.3.6.1.4.1.3607.6.10.30.0.470
remote Failure Indication
NOTIFICATION-TYPE    

remoteFailureIndicationLine 1.3.6.1.4.1.3607.6.10.30.0.480
remote Failure Indication LINE
NOTIFICATION-TYPE    

remoteFailureIndicationPath 1.3.6.1.4.1.3607.6.10.30.0.490
remote Failure Indication Path
NOTIFICATION-TYPE    

remoteFailureIndicationVT 1.3.6.1.4.1.3607.6.10.30.0.500
remote Failure Indication VT
NOTIFICATION-TYPE    

signalDegrade 1.3.6.1.4.1.3607.6.10.30.0.510
facility has passed BER Threshold for Signal Degrade
NOTIFICATION-TYPE    

severelyErroredFrame 1.3.6.1.4.1.3607.6.10.30.0.520
severely Errored Frame
NOTIFICATION-TYPE    

signalFailure 1.3.6.1.4.1.3607.6.10.30.0.530
facility has passed BER threshold for Signal Failure
NOTIFICATION-TYPE    

signalLabelMismatchFailure 1.3.6.1.4.1.3607.6.10.30.0.540
signal Label Mismatch Failure
NOTIFICATION-TYPE    

payloadDefectIndication 1.3.6.1.4.1.3607.6.10.30.0.550
Payload Defect Indication
NOTIFICATION-TYPE    

payloadDefectIndicationPath 1.3.6.1.4.1.3607.6.10.30.0.560
Payload Defect Indication - Path
NOTIFICATION-TYPE    

payloadLabelMismatchPath 1.3.6.1.4.1.3607.6.10.30.0.570
Payload Label Mismatch - Path
NOTIFICATION-TYPE    

signalLabelMismatchFailurePayloadLabelMismatchVT 1.3.6.1.4.1.3607.6.10.30.0.580
signal Label Mismatch Failure Payload Label Mismatch VT
NOTIFICATION-TYPE    

unequippedPath 1.3.6.1.4.1.3607.6.10.30.0.590
Unequipped - Path
NOTIFICATION-TYPE    

signalLabelMismatchFailureUnequippedVT 1.3.6.1.4.1.3607.6.10.30.0.600
signal Label Mismatch Failure Unequipped VT
NOTIFICATION-TYPE    

lossOfSynchronization 1.3.6.1.4.1.3607.6.10.30.0.610
Loss of Synchronization
NOTIFICATION-TYPE    

outOfSynchronization 1.3.6.1.4.1.3607.6.10.30.0.620
Out of Synchronization
NOTIFICATION-TYPE    

primarySynchronizationReferenceFailure 1.3.6.1.4.1.3607.6.10.30.0.630
Primary Synchronization Reference Failure
NOTIFICATION-TYPE    

secondarySynchronizationReferenceFailure 1.3.6.1.4.1.3607.6.10.30.0.640
Secondary Synchronization Reference Failure
NOTIFICATION-TYPE    

thirdSynchronizationReferenceFailure 1.3.6.1.4.1.3607.6.10.30.0.650
Third Synchronization Reference Failure
NOTIFICATION-TYPE    

fourthSynchronizationReferenceFailure 1.3.6.1.4.1.3607.6.10.30.0.660
Fourth Synchronization Reference Failure
NOTIFICATION-TYPE    

fifthSynchronizationReferenceFailure 1.3.6.1.4.1.3607.6.10.30.0.670
Fifth Synchronization Reference Failure
NOTIFICATION-TYPE    

sixthSynchronizationReferenceFailure 1.3.6.1.4.1.3607.6.10.30.0.680
Sixth Synchronization Reference Failure
NOTIFICATION-TYPE    

failedToReceiveSynchronizationStatusMessage 1.3.6.1.4.1.3607.6.10.30.0.690
failed to receive Synchronization Status Message
NOTIFICATION-TYPE    

synchronizationStatusMessagesAreDisabledOnThisInterface 1.3.6.1.4.1.3607.6.10.30.0.700
synchronization Status Messages are disabled on this interface
NOTIFICATION-TYPE    

stratum1PrimaryReferenceSourceTraceable 1.3.6.1.4.1.3607.6.10.30.0.710
Stratum1 Primary Reference Source Traceable
NOTIFICATION-TYPE    

synchronizedTraceabilityUnknown 1.3.6.1.4.1.3607.6.10.30.0.720
synchronized Traceability Unknown
NOTIFICATION-TYPE    

stratum2Traceable 1.3.6.1.4.1.3607.6.10.30.0.730
stratum 2 Traceable
NOTIFICATION-TYPE    

transitNodeClockTraceable 1.3.6.1.4.1.3607.6.10.30.0.740
transit Node clock Traceable
NOTIFICATION-TYPE    

stratum3ETraceable 1.3.6.1.4.1.3607.6.10.30.0.750
stratum 3E Traceable
NOTIFICATION-TYPE    

stratum3Traceable 1.3.6.1.4.1.3607.6.10.30.0.760
stratum 3 Traceable
NOTIFICATION-TYPE    

sonetMinimumClockTraceable 1.3.6.1.4.1.3607.6.10.30.0.770
SONET Minimum Clock Traceable
NOTIFICATION-TYPE    

stratum4Traceable 1.3.6.1.4.1.3607.6.10.30.0.780
stratum 4 Traceable
NOTIFICATION-TYPE    

doNotUseForSynchronization 1.3.6.1.4.1.3607.6.10.30.0.790
do not Use for Synchronization
NOTIFICATION-TYPE    

reservedForNetworkSynchronizationUse 1.3.6.1.4.1.3607.6.10.30.0.800
reserved for Network Synchronization Use
NOTIFICATION-TYPE    

outgoingFailureCondition 1.3.6.1.4.1.3607.6.10.30.0.810
outgoing failure condition
NOTIFICATION-TYPE    

remoteDefectIndicationLine 1.3.6.1.4.1.3607.6.10.30.0.820
remote Defect Indication LINE
NOTIFICATION-TYPE    

remoteDefectIndicationPath 1.3.6.1.4.1.3607.6.10.30.0.830
remote Defect Indication Path
NOTIFICATION-TYPE    

freeRunningSynchronizationMode 1.3.6.1.4.1.3607.6.10.30.0.840
free Running Synchronization mode
NOTIFICATION-TYPE    

holdoverSynchronizationMode 1.3.6.1.4.1.3607.6.10.30.0.850
holdover synchronization mode
NOTIFICATION-TYPE    

fastStartSynchronizationMode 1.3.6.1.4.1.3607.6.10.30.0.860
fast Start synchronization mode
NOTIFICATION-TYPE    

internalFault 1.3.6.1.4.1.3607.6.10.30.0.870
Internal Fault
NOTIFICATION-TYPE    

internalError 1.3.6.1.4.1.3607.6.10.30.0.880
Internal Error
NOTIFICATION-TYPE    

internalMessageError 1.3.6.1.4.1.3607.6.10.30.0.890
internal Message Error
NOTIFICATION-TYPE    

mismatchOfEquipmentAndAttributes 1.3.6.1.4.1.3607.6.10.30.0.900
mismatch of Equipment and Attributes
NOTIFICATION-TYPE    

watchdogTimerTimeout 1.3.6.1.4.1.3607.6.10.30.0.910
watchdog Timer Timeout
NOTIFICATION-TYPE    

softwareFaultOrFailure 1.3.6.1.4.1.3607.6.10.30.0.920
software Fault or failure
NOTIFICATION-TYPE    

softwareFaultDataIntegrityFault 1.3.6.1.4.1.3607.6.10.30.0.930
software Fault - Data integrity fault : The newly added provisioning or hardware has caused the database to grow beyond its limit. That is, the newly added object(s) in the system has(have) enough memory to exist onboard but too large to be saved in the database.
NOTIFICATION-TYPE    

programFailure 1.3.6.1.4.1.3607.6.10.30.0.940
program failure
NOTIFICATION-TYPE    

controlEquipmentFailure 1.3.6.1.4.1.3607.6.10.30.0.950
control Equipment failure
NOTIFICATION-TYPE    

primaryNonVolatileBackupMemoryFailure 1.3.6.1.4.1.3607.6.10.30.0.960
Primary Non-Volatile Backup Memory Failure
NOTIFICATION-TYPE    

secondaryNonVolatileBackupMemoryFailure 1.3.6.1.4.1.3607.6.10.30.0.970
Secondary Non-Volatile Backup Memory Failure
NOTIFICATION-TYPE    

controlBusFailure 1.3.6.1.4.1.3607.6.10.30.0.980
Control Bus Failure
NOTIFICATION-TYPE    

controlBus1Failure 1.3.6.1.4.1.3607.6.10.30.0.990
Control Bus 1 Failure
NOTIFICATION-TYPE    

controlBus2Failure 1.3.6.1.4.1.3607.6.10.30.0.1000
Control Bus 2 Failure
NOTIFICATION-TYPE    

tccAToShelfSlot1DROP1CommunicationFailure 1.3.6.1.4.1.3607.6.10.30.0.1010
TCC A To Shelf Slot 1 (DROP 1) Communication Failure
NOTIFICATION-TYPE    

tccAToShelfSlot2DROP2CommunicationFailure 1.3.6.1.4.1.3607.6.10.30.0.1020
TCC A To Shelf Slot 2 (DROP 2) Communication Failure
NOTIFICATION-TYPE    

tccAToShelfSlot3DROP3CommunicationFailure 1.3.6.1.4.1.3607.6.10.30.0.1030
TCC A To Shelf Slot 3 (DROP 3) Communication Failure
NOTIFICATION-TYPE    

tccAToShelfSlot4DROP4CommunicationFailure 1.3.6.1.4.1.3607.6.10.30.0.1040
TCC A To Shelf Slot 4 (DROP 4) Communication Failure
NOTIFICATION-TYPE    

tccAToShelfSlot5TRUNK1CommunicationFailure 1.3.6.1.4.1.3607.6.10.30.0.1050
TCC A To Shelf Slot 5 (TRUNK 1) Communication Failure
NOTIFICATION-TYPE    

tccAToShelfSlot6TRUNK2CommunicationFailure 1.3.6.1.4.1.3607.6.10.30.0.1060
TCC A To Shelf Slot 6 (TRUNK 2) Communication Failure
NOTIFICATION-TYPE    

tccAToShelfSlot7TCCACommunicationFailure 1.3.6.1.4.1.3607.6.10.30.0.1070
TCC A To Shelf Slot 7 (TCC A) Communication Failure
NOTIFICATION-TYPE    

tccAToShelfSlot8XCONACommunicationFailure 1.3.6.1.4.1.3607.6.10.30.0.1080
TCC A To Shelf Slot 8 (XCON A) Communication Failure
NOTIFICATION-TYPE    

tccAToShelfSlot9AICCommunicationFailure 1.3.6.1.4.1.3607.6.10.30.0.1090
TCC A To Shelf Slot 9 (AIC) Communication Failure
NOTIFICATION-TYPE    

tccAToShelfSlot10XCONBCommunicationFailure 1.3.6.1.4.1.3607.6.10.30.0.1100
TCC A To Shelf Slot 10 (XCON B) Communication Failure
NOTIFICATION-TYPE    

tccAToShelfSlot11TCCBCommunicationFailure 1.3.6.1.4.1.3607.6.10.30.0.1110
TCC A To Shelf Slot 11 (TCC B) Communication Failure
NOTIFICATION-TYPE    

tccAToShelfSlot12TRUNK3CommunicationFailure 1.3.6.1.4.1.3607.6.10.30.0.1120
TCC A To Shelf Slot 12 (TRUNK 3) Communication Failure
NOTIFICATION-TYPE    

tccAToShelfSlot13TRUNK4CommunicationFailure 1.3.6.1.4.1.3607.6.10.30.0.1130
TCC A To Shelf Slot 13 (TRUNK 4) Communication Failure
NOTIFICATION-TYPE    

tccAToShelfSlot14DROP5CommunicationFailure 1.3.6.1.4.1.3607.6.10.30.0.1140
TCC A To Shelf Slot 14 (DROP 5) Communication Failure
NOTIFICATION-TYPE    

tccAToShelfSlot15DROP6CommunicationFailure 1.3.6.1.4.1.3607.6.10.30.0.1150
TCC A To Shelf Slot 15 (DROP 6) Communication Failure
NOTIFICATION-TYPE    

tccAToShelfSlot16DROP7CommunicationFailure 1.3.6.1.4.1.3607.6.10.30.0.1160
TCC A To Shelf Slot 16 (DROP 7) Communication Failure
NOTIFICATION-TYPE    

tccAToShelfSlot17DROP8CommunicationFailure 1.3.6.1.4.1.3607.6.10.30.0.1170
TCC A To Shelf Slot 17 (DROP 8) Communication Failure
NOTIFICATION-TYPE    

tccAToDCCAProcessorCommunicationFailure 1.3.6.1.4.1.3607.6.10.30.0.1180
communication failure TCC A to DCC A processor
NOTIFICATION-TYPE    

tccBToShelfSlot1DROP1CommunicationFailure 1.3.6.1.4.1.3607.6.10.30.0.1190
TCC B To Shelf Slot 1 (DROP 1) Communication Failure
NOTIFICATION-TYPE    

tccBToShelfSlot2DROP2CommunicationFailure 1.3.6.1.4.1.3607.6.10.30.0.1200
TCC B To Shelf Slot 2 (DROP 2) Communication Failure
NOTIFICATION-TYPE    

tccBToShelfSlot3DROP3CommunicationFailure 1.3.6.1.4.1.3607.6.10.30.0.1210
TCC B To Shelf Slot 3 (DROP 3) Communication Failure
NOTIFICATION-TYPE    

tccBToShelfSlot4DROP4CommunicationFailure 1.3.6.1.4.1.3607.6.10.30.0.1220
TCC B To Shelf Slot 4 (DROP 4) Communication Failure
NOTIFICATION-TYPE    

tccBToShelfSlot5TRUNK1CommunicationFailure 1.3.6.1.4.1.3607.6.10.30.0.1230
TCC B To Shelf Slot 5 (TRUNK 1) Communication Failure
NOTIFICATION-TYPE    

tccBToShelfSlot6TRUNK2CommunicationFailure 1.3.6.1.4.1.3607.6.10.30.0.1240
TCC B To Shelf Slot 6 (TRUNK 2) Communication Failure
NOTIFICATION-TYPE    

tccBToShelfSlot7TCCACommunicationFailure 1.3.6.1.4.1.3607.6.10.30.0.1250
TCC B To Shelf Slot 7 (TCC A) Communication Failure
NOTIFICATION-TYPE    

tccBToShelfSlot8XCONACommunicationFailure 1.3.6.1.4.1.3607.6.10.30.0.1260
TCC B To Shelf Slot 8 (XCON A) Communication Failure
NOTIFICATION-TYPE    

tccBToShelfSlot9AICCommunicationFailure 1.3.6.1.4.1.3607.6.10.30.0.1270
TCC B To Shelf Slot 9 (AIC) Communication Failure
NOTIFICATION-TYPE    

tccBToShelfSlot10XCONBCommunicationFailure 1.3.6.1.4.1.3607.6.10.30.0.1280
TCC B To Shelf Slot 10 (XCON B) Communication Failure
NOTIFICATION-TYPE    

tccBToShelfSlot11TCCBCommunicationFailure 1.3.6.1.4.1.3607.6.10.30.0.1290
TCC B To Shelf Slot 11 (TCC B) Communication Failure
NOTIFICATION-TYPE    

tccBToShelfSlot12TRUNK3CommunicationFailure 1.3.6.1.4.1.3607.6.10.30.0.1300
TCC B To Shelf Slot 12 (TRUNK 3) Communication Failure
NOTIFICATION-TYPE    

tccBToShelfSlot13TRUNK4CommunicationFailure 1.3.6.1.4.1.3607.6.10.30.0.1310
TCC B To Shelf Slot 13 (TRUNK 4) Communication Failure
NOTIFICATION-TYPE    

tccBToShelfSlot14DROP5CommunicationFailure 1.3.6.1.4.1.3607.6.10.30.0.1320
TCC B To Shelf Slot 14 (DROP 5) Communication Failure
NOTIFICATION-TYPE    

tccBToShelfSlot15DROP6CommunicationFailure 1.3.6.1.4.1.3607.6.10.30.0.1330
TCC B To Shelf Slot 15 (DROP 6) Communication Failure
NOTIFICATION-TYPE    

tccBToShelfSlot16DROP7CommunicationFailure 1.3.6.1.4.1.3607.6.10.30.0.1340
TCC B To Shelf Slot 16 (DROP 7) Communication Failure
NOTIFICATION-TYPE    

tccBToShelfSlot17DROP8CommunicationFailure 1.3.6.1.4.1.3607.6.10.30.0.1350
TCC B To Shelf Slot 17 (DROP 8) Communication Failure
NOTIFICATION-TYPE    

tccBToDCCBProcessorCommunicationFailure 1.3.6.1.4.1.3607.6.10.30.0.1360
TCC B To DCC B Processor Communication Failure
NOTIFICATION-TYPE    

controlEquipmentControlCommunicationsEquipmentFailure 1.3.6.1.4.1.3607.6.10.30.0.1370
control Equipment Control Communications equipment failure
NOTIFICATION-TYPE    

controlProcessorFailure 1.3.6.1.4.1.3607.6.10.30.0.1380
Control Processor Failure
NOTIFICATION-TYPE    

workingMemoryFailure 1.3.6.1.4.1.3607.6.10.30.0.1390
Working Memory Failure
NOTIFICATION-TYPE    

interconnectionEquipmentFailure 1.3.6.1.4.1.3607.6.10.30.0.1400
interconnection Equipment failure
NOTIFICATION-TYPE    

payloadBusFailureToIOSlot1XCONSlot8 1.3.6.1.4.1.3607.6.10.30.0.1410
Payload Bus Failure To IO Slot 1 (XCON Slot 8)
NOTIFICATION-TYPE    

payloadBusFailureToIOSlot2XCONSlot8 1.3.6.1.4.1.3607.6.10.30.0.1420
Payload Bus Failure To IO Slot 2 (XCON Slot 8)
NOTIFICATION-TYPE    

payloadBusFailureToIOSlot3XCONSlot8 1.3.6.1.4.1.3607.6.10.30.0.1430
Payload Bus Failure To IO Slot 3 (XCON Slot 8)
NOTIFICATION-TYPE    

payloadBusFailureToIOSlot4XCONSlot8 1.3.6.1.4.1.3607.6.10.30.0.1440
Payload Bus Failure To IO Slot 4 (XCON Slot 8)
NOTIFICATION-TYPE    

payloadBusFailureToIOSlot5XCONSlot8 1.3.6.1.4.1.3607.6.10.30.0.1450
Payload Bus Failure To IO Slot 5 (XCON Slot 8)
NOTIFICATION-TYPE    

payloadBusFailureToIOSlot6XCONSlot8 1.3.6.1.4.1.3607.6.10.30.0.1460
Payload Bus Failure To IO Slot 6 (XCON Slot 8)
NOTIFICATION-TYPE    

payloadBusFailureToIOSlot12XCONSlot8 1.3.6.1.4.1.3607.6.10.30.0.1470
Payload Bus Failure To IO Slot 12 (XCON Slot 8)
NOTIFICATION-TYPE    

payloadBusFailureToIOSlot13XCONSlot8 1.3.6.1.4.1.3607.6.10.30.0.1480
Payload Bus Failure To IO Slot 13 (XCON Slot 8)
NOTIFICATION-TYPE    

payloadBusFailureToIOSlot14XCONSlot8 1.3.6.1.4.1.3607.6.10.30.0.1490
Payload Bus Failure To IO Slot 14 (XCON Slot 8)
NOTIFICATION-TYPE    

payloadBusFailureToIOSlot15XCONSlot8 1.3.6.1.4.1.3607.6.10.30.0.1500
Payload Bus Failure To IO Slot 15 (XCON Slot 8)
NOTIFICATION-TYPE    

payloadBusFailureToIOSlot16XCONSlot8 1.3.6.1.4.1.3607.6.10.30.0.1510
Payload Bus Failure To IO Slot 16 (XCON Slot 8)
NOTIFICATION-TYPE    

payloadBusFailureToIOSlot17XCONSlot8 1.3.6.1.4.1.3607.6.10.30.0.1520
Payload Bus Failure To IO Slot 17 (XCON Slot 8)
NOTIFICATION-TYPE    

payloadBusFailureToIOSlot1XCONSlot10 1.3.6.1.4.1.3607.6.10.30.0.1530
Payload Bus Failure To IO Slot 1 (XCON Slot 10)
NOTIFICATION-TYPE    

payloadBusFailureToIOSlot2XCONSlot10 1.3.6.1.4.1.3607.6.10.30.0.1540
Payload Bus Failure To IO Slot 2 (XCON Slot 10)
NOTIFICATION-TYPE    

payloadBusFailureToIOSlot3XCONSlot10 1.3.6.1.4.1.3607.6.10.30.0.1550
Payload Bus Failure To IO Slot 3 (XCON Slot 10)
NOTIFICATION-TYPE    

payloadBusFailureToIOSlot4XCONSlot10 1.3.6.1.4.1.3607.6.10.30.0.1560
Payload Bus Failure To IO Slot 4 (XCON Slot 10)
NOTIFICATION-TYPE    

payloadBusFailureToIOSlot5XCONSlot10 1.3.6.1.4.1.3607.6.10.30.0.1570
Payload Bus Failure To IO Slot 5 (XCON Slot 10)
NOTIFICATION-TYPE    

payloadBusFailureToIOSlot6XCONSlot10 1.3.6.1.4.1.3607.6.10.30.0.1580
Payload Bus Failure To IO Slot 6 (XCON Slot 10)
NOTIFICATION-TYPE    

payloadBusFailureToIOSlot12XCONSlot10 1.3.6.1.4.1.3607.6.10.30.0.1590
Payload Bus Failure To IO Slot 12 (XCON Slot 10)
NOTIFICATION-TYPE    

payloadBusFailureToIOSlot13XCONSlot10 1.3.6.1.4.1.3607.6.10.30.0.1600
Payload Bus Failure To IO Slot 13 (XCON Slot 10)
NOTIFICATION-TYPE    

payloadBusFailureToIOSlot14XCONSlot10 1.3.6.1.4.1.3607.6.10.30.0.1610
Payload Bus Failure To IO Slot 14 (XCON Slot 10)
NOTIFICATION-TYPE    

payloadBusFailureToIOSlot15XCONSlot10 1.3.6.1.4.1.3607.6.10.30.0.1620
Payload Bus Failure To IO Slot 15 (XCON Slot 10)
NOTIFICATION-TYPE    

payloadBusFailureToIOSlot16XCONSlot10 1.3.6.1.4.1.3607.6.10.30.0.1630
Payload Bus Failure To IO Slot 16 (XCON Slot 10)
NOTIFICATION-TYPE    

payloadBusFailureToIOSlot17XCONSlot10 1.3.6.1.4.1.3607.6.10.30.0.1640
Payload Bus Failure To IO Slot 17 (XCON Slot 10)
NOTIFICATION-TYPE    

timeSlotInterchangeEquipmentFailure 1.3.6.1.4.1.3607.6.10.30.0.1650
Time Slot Interchange Equipment Failure
NOTIFICATION-TYPE    

equipmentFailure 1.3.6.1.4.1.3607.6.10.30.0.1660
equipment failure
NOTIFICATION-TYPE    

highTemperature 1.3.6.1.4.1.3607.6.10.30.0.1670
High Temperature
NOTIFICATION-TYPE    

invalidMACAddress 1.3.6.1.4.1.3607.6.10.30.0.1680
Invalid MAC Address
NOTIFICATION-TYPE    

boardFailure 1.3.6.1.4.1.3607.6.10.30.0.1690
Board Failure
NOTIFICATION-TYPE    

diagnosticFailure 1.3.6.1.4.1.3607.6.10.30.0.1700
equipment failure Diagnostics Failure
NOTIFICATION-TYPE    

mediumAccessControlFailure 1.3.6.1.4.1.3607.6.10.30.0.1710
Medium Access Control Failure
NOTIFICATION-TYPE    

facilityTerminationEquipmentFailure 1.3.6.1.4.1.3607.6.10.30.0.1720
facility Termination equipment failure
NOTIFICATION-TYPE    

automaticLaserShutoffDueToHighTemperature 1.3.6.1.4.1.3607.6.10.30.0.1730
Automatic Laser Shutoff Due To High Temperature
NOTIFICATION-TYPE    

failureToReleaseFromProtection 1.3.6.1.4.1.3607.6.10.30.0.1740
failure To Release from protection
NOTIFICATION-TYPE    

receiverFailure 1.3.6.1.4.1.3607.6.10.30.0.1750
Receiver Failure
NOTIFICATION-TYPE    

transmitFailure 1.3.6.1.4.1.3607.6.10.30.0.1760
Transmit Failure
NOTIFICATION-TYPE    

facilityTerminationEquipmentReceiverMissing 1.3.6.1.4.1.3607.6.10.30.0.1770
facility Termination equipment Receiver missing
NOTIFICATION-TYPE    

facilityTerminationEquipmentTransmitterMissing 1.3.6.1.4.1.3607.6.10.30.0.1780
facility Termination equipment Transmitter missing
NOTIFICATION-TYPE    

failureToSwitchToProtection 1.3.6.1.4.1.3607.6.10.30.0.1790
failure To Switch to protection
NOTIFICATION-TYPE    

failureToSwitchToProtectionRing 1.3.6.1.4.1.3607.6.10.30.0.1800
failure To Switch to protection Ring
NOTIFICATION-TYPE    

failureToSwitchToProtectionSpan 1.3.6.1.4.1.3607.6.10.30.0.1810
failure To Switch to protection Span
NOTIFICATION-TYPE    

failureToSwitchToProtectionPath 1.3.6.1.4.1.3607.6.10.30.0.1820
failure to Switch to protection Path
NOTIFICATION-TYPE    

fanFailure 1.3.6.1.4.1.3607.6.10.30.0.1830
Fan Failure
NOTIFICATION-TYPE    

equipmentUnitPlugIn 1.3.6.1.4.1.3607.6.10.30.0.1840
equipment unit plug in
NOTIFICATION-TYPE    

nePowerFailureAtConnector 1.3.6.1.4.1.3607.6.10.30.0.1850
NE Power Failure At Connector
NOTIFICATION-TYPE    

fuseAlarm 1.3.6.1.4.1.3607.6.10.30.0.1860
Fuse Alarm
NOTIFICATION-TYPE    

synchronizationUnitFailure 1.3.6.1.4.1.3607.6.10.30.0.1870
synchronization unit failure
NOTIFICATION-TYPE    

synchronizationSwitchingEquipmentFailure 1.3.6.1.4.1.3607.6.10.30.0.1880
synchronization switching Equipment failure
NOTIFICATION-TYPE    

equipmentUnitUnplugged 1.3.6.1.4.1.3607.6.10.30.0.1890
Equipment Unit Un-plugged
NOTIFICATION-TYPE    

loopback 1.3.6.1.4.1.3607.6.10.30.0.1900
loop back
NOTIFICATION-TYPE    

ds1LoopbackDueToFEACCommand 1.3.6.1.4.1.3607.6.10.30.0.1910
DS1 Loopback Due To FEAC Command
NOTIFICATION-TYPE    

loopbackCommandSentToFarEndDS1 1.3.6.1.4.1.3607.6.10.30.0.1920
loopback Command sent to Far End DS1
NOTIFICATION-TYPE    

ds3LoopbackDueToFEACCommand 1.3.6.1.4.1.3607.6.10.30.0.1930
loopback due to FEAC command DS3
NOTIFICATION-TYPE    

ds3LoopbackCommandSentToFarEnd 1.3.6.1.4.1.3607.6.10.30.0.1940
DS3 Loopback Command Sent To Far End
NOTIFICATION-TYPE    

ds2LoopbackDueToFarEndCommand 1.3.6.1.4.1.3607.6.10.30.0.1950
DS2 Loopback Due To Far End Command
NOTIFICATION-TYPE    

ds2LoopbackCommandSentToFarEnd 1.3.6.1.4.1.3607.6.10.30.0.1960
DS2 Loopback Command Sent To Far End
NOTIFICATION-TYPE    

facilityLoopback 1.3.6.1.4.1.3607.6.10.30.0.1970
Facility Loopback
NOTIFICATION-TYPE    

networkLoopback 1.3.6.1.4.1.3607.6.10.30.0.1980
Network Loopback
NOTIFICATION-TYPE    

terminalLoopback 1.3.6.1.4.1.3607.6.10.30.0.1990
Terminal Loopback
NOTIFICATION-TYPE    

manuallyCausedAbnormalCondition 1.3.6.1.4.1.3607.6.10.30.0.2000
manually caused abnormal condition
NOTIFICATION-TYPE    

ethernetBridgeIsNewRootOfSpanningTree 1.3.6.1.4.1.3607.6.10.30.0.2010
Ethernet Bridge Is New Root Of Spanning Tree
NOTIFICATION-TYPE    

ethernetBridgeTopologyChange 1.3.6.1.4.1.3607.6.10.30.0.2020
Ethernet Bridge Topology Change
NOTIFICATION-TYPE    

normalCondition 1.3.6.1.4.1.3607.6.10.30.0.2030
normal condition
NOTIFICATION-TYPE    

embeddedOperationsChannelFailureLinkDown 1.3.6.1.4.1.3607.6.10.30.0.2040
embedded Operations Channel failure link down
NOTIFICATION-TYPE    

peerStateMismatch 1.3.6.1.4.1.3607.6.10.30.0.2050
peer state mismatch
NOTIFICATION-TYPE    

proceduralError 1.3.6.1.4.1.3607.6.10.30.0.2060
procedural Error
NOTIFICATION-TYPE    

improperRemoval 1.3.6.1.4.1.3607.6.10.30.0.2070
Improper Removal
NOTIFICATION-TYPE    

duplicateNodeID 1.3.6.1.4.1.3607.6.10.30.0.2080
Duplicate Node ID
NOTIFICATION-TYPE    

blsrOutOfSync 1.3.6.1.4.1.3607.6.10.30.0.2090
BLSR out of sync
NOTIFICATION-TYPE    

blsrMultiNodeTableUpdateCompleted 1.3.6.1.4.1.3607.6.10.30.0.2100
BLSR Multi-Node Table Update Completed
NOTIFICATION-TYPE    

protectionUnitNotAvailable 1.3.6.1.4.1.3607.6.10.30.0.2110
protection unit not available
NOTIFICATION-TYPE    

performanceMonitorThresholdCrossingAlert 1.3.6.1.4.1.3607.6.10.30.0.2120
performance Monitor Threshold Crossing Alert
NOTIFICATION-TYPE    

protectionSwitch 1.3.6.1.4.1.3607.6.10.30.0.2130
Protection Switch
NOTIFICATION-TYPE    

recoveryOrServiceProtectionActionHasBeenInitiated 1.3.6.1.4.1.3607.6.10.30.0.2140
recovery or service protection action has been initiated
NOTIFICATION-TYPE    

automaticSystemReset 1.3.6.1.4.1.3607.6.10.30.0.2150
automatic system Reset
NOTIFICATION-TYPE    

automaticUPSRSwitchCausedByAIS 1.3.6.1.4.1.3607.6.10.30.0.2160
automatic UPSR switch caused by AIS
NOTIFICATION-TYPE    

automaticUPSRSwitchCausedByLOP 1.3.6.1.4.1.3607.6.10.30.0.2170
automatic UPSR switch caused by Lop
NOTIFICATION-TYPE    

automaticUPSRSwitchCausedByUNEQ 1.3.6.1.4.1.3607.6.10.30.0.2180
Automatic UPSR Switch Caused By UNEQ
NOTIFICATION-TYPE    

automaticUPSRSwitchCausedByPDI 1.3.6.1.4.1.3607.6.10.30.0.2190
automatic UPSR switch caused by PDI
NOTIFICATION-TYPE    

automaticUPSRSwitchCausedBySFBER 1.3.6.1.4.1.3607.6.10.30.0.2200
Automatic UPSR Switch Caused By SFBER
NOTIFICATION-TYPE    

automaticUPSRSwitchCausedBySDBER 1.3.6.1.4.1.3607.6.10.30.0.2210
Automatic UPSR Switch Caused By SDBER
NOTIFICATION-TYPE    

coldRestart 1.3.6.1.4.1.3607.6.10.30.0.2220
cold Restart
NOTIFICATION-TYPE    

forcedSwitchBackToWorking 1.3.6.1.4.1.3607.6.10.30.0.2230
Forced Switch Back To Working
NOTIFICATION-TYPE    

forcedSwitchBackToWorkingRing 1.3.6.1.4.1.3607.6.10.30.0.2240
Forced Switch Back To Working - Ring
NOTIFICATION-TYPE    

forcedSwitchBackToWorkingSpan 1.3.6.1.4.1.3607.6.10.30.0.2250
Forced Switch Back To Working - Span
NOTIFICATION-TYPE    

forcedSwitchToProtection 1.3.6.1.4.1.3607.6.10.30.0.2260
Forced Switch To Protection
NOTIFICATION-TYPE    

forcedSwitchToProtectionRing 1.3.6.1.4.1.3607.6.10.30.0.2270
Forced Switch To Protection - Ring
NOTIFICATION-TYPE    

forcedSwitchToProtectionSpan 1.3.6.1.4.1.3607.6.10.30.0.2280
Forced Switch To Protection - Span
NOTIFICATION-TYPE    

workingFacilityOrEquipmentForcedToSwitchToProtectionPath 1.3.6.1.4.1.3607.6.10.30.0.2290
Working Facility or Equipment Forced To Switch To Protection - Path
NOTIFICATION-TYPE    

initializationInitiated 1.3.6.1.4.1.3607.6.10.30.0.2300
initialization initiated
NOTIFICATION-TYPE    

lockoutOfProtection 1.3.6.1.4.1.3607.6.10.30.0.2310
lockout of Protection
NOTIFICATION-TYPE    

lockoutOfProtectionRing 1.3.6.1.4.1.3607.6.10.30.0.2320
lockout of Protection Ring
NOTIFICATION-TYPE    

lockoutOfProtectionSpan 1.3.6.1.4.1.3607.6.10.30.0.2330
lockout of Protection Span
NOTIFICATION-TYPE    

lockoutOfProtectionPath 1.3.6.1.4.1.3607.6.10.30.0.2340
lockout of Protection Path
NOTIFICATION-TYPE    

lockoutOfWorking 1.3.6.1.4.1.3607.6.10.30.0.2350
lockout of working
NOTIFICATION-TYPE    

lockoutOfWorkingRing 1.3.6.1.4.1.3607.6.10.30.0.2360
lockout of working Ring
NOTIFICATION-TYPE    

lockoutOfWorkingSpan 1.3.6.1.4.1.3607.6.10.30.0.2370
lockout of working Span
NOTIFICATION-TYPE    

manualSystemReset 1.3.6.1.4.1.3607.6.10.30.0.2380
manual system Reset
NOTIFICATION-TYPE    

manualSwitchToInternalClock 1.3.6.1.4.1.3607.6.10.30.0.2390
Manual Switch to Internal Clock
NOTIFICATION-TYPE    

manualSwitchToPrimaryReference 1.3.6.1.4.1.3607.6.10.30.0.2400
Manual Switch To Primary Reference
NOTIFICATION-TYPE    

manualSwitchToSecondReference 1.3.6.1.4.1.3607.6.10.30.0.2410
Manual Switch To Second Reference
NOTIFICATION-TYPE    

manualSwitchToThirdReference 1.3.6.1.4.1.3607.6.10.30.0.2420
Manual Switch To Third reference
NOTIFICATION-TYPE    

manualSwitchToFourthReference 1.3.6.1.4.1.3607.6.10.30.0.2430
Manual Switch To Fourth reference
NOTIFICATION-TYPE    

manualSwitchToFifthReference 1.3.6.1.4.1.3607.6.10.30.0.2440
Manual Switch To Fifth reference
NOTIFICATION-TYPE    

manualSwitchToSixthReference 1.3.6.1.4.1.3607.6.10.30.0.2450
Manual Switch To Sixth reference
NOTIFICATION-TYPE    

manualSwitchBackToWorking 1.3.6.1.4.1.3607.6.10.30.0.2460
Manual Switch Back To Working
NOTIFICATION-TYPE    

manualSwitchBackToWorkingRing 1.3.6.1.4.1.3607.6.10.30.0.2470
Manual Switch Back To Working - Ring
NOTIFICATION-TYPE    

manualSwitchBackToWorkingSpan 1.3.6.1.4.1.3607.6.10.30.0.2480
Manual Switch Back To Working - Span
NOTIFICATION-TYPE    

manualSwitchToProtection 1.3.6.1.4.1.3607.6.10.30.0.2490
Manual Switch To Protection
NOTIFICATION-TYPE    

manualSwitchToProtectionRing 1.3.6.1.4.1.3607.6.10.30.0.2500
Manual Switch To Protection - Ring
NOTIFICATION-TYPE    

manualSwitchToProtectionSpan 1.3.6.1.4.1.3607.6.10.30.0.2510
Manual Switch To Protection - Span
NOTIFICATION-TYPE    

manualSwitchOfWorkingFacilityOrEquipmentToProtectionPath 1.3.6.1.4.1.3607.6.10.30.0.2520
Manual Switch Of Working Facility or Equipment To Protection - Path
NOTIFICATION-TYPE    

powerfailRestart 1.3.6.1.4.1.3607.6.10.30.0.2530
Powerfail Restart
NOTIFICATION-TYPE    

ringIsSquelchingTraffic 1.3.6.1.4.1.3607.6.10.30.0.2540
ring is squelching traffic
NOTIFICATION-TYPE    

softwareDownloadInProgress 1.3.6.1.4.1.3607.6.10.30.0.2550
software download in progress
NOTIFICATION-TYPE    

switchToInternalClock 1.3.6.1.4.1.3607.6.10.30.0.2560
Switch To Internal clock
NOTIFICATION-TYPE    

switchToPrimaryReference 1.3.6.1.4.1.3607.6.10.30.0.2570
Switch To Primary refernce
NOTIFICATION-TYPE    

switchToSecondReference 1.3.6.1.4.1.3607.6.10.30.0.2580
Switch To Second Reference
NOTIFICATION-TYPE    

switchToThirdReference 1.3.6.1.4.1.3607.6.10.30.0.2590
Switch To Third refernce
NOTIFICATION-TYPE    

switchToFourthReference 1.3.6.1.4.1.3607.6.10.30.0.2600
Switch To Fourth refernce
NOTIFICATION-TYPE    

switchToFifthReference 1.3.6.1.4.1.3607.6.10.30.0.2610
Switch To Fifth refernce
NOTIFICATION-TYPE    

switchToSixthReference 1.3.6.1.4.1.3607.6.10.30.0.2620
Switch To Sixth refernce
NOTIFICATION-TYPE    

systemReboot 1.3.6.1.4.1.3607.6.10.30.0.2630
system reboot
NOTIFICATION-TYPE    

switchedBackToWorking 1.3.6.1.4.1.3607.6.10.30.0.2640
Switched Back To Working
NOTIFICATION-TYPE    

switchedToProtection 1.3.6.1.4.1.3607.6.10.30.0.2650
Switched To Protection
NOTIFICATION-TYPE    

warmRestart 1.3.6.1.4.1.3607.6.10.30.0.2660
warm Restart
NOTIFICATION-TYPE    

ringIsInWaitToRestoreState 1.3.6.1.4.1.3607.6.10.30.0.2670
Ring is in Wait To Restore state
NOTIFICATION-TYPE    

manualSwitchRequest 1.3.6.1.4.1.3607.6.10.30.0.2680
Manual Switch Request
NOTIFICATION-TYPE    

forcedSwitchRequest 1.3.6.1.4.1.3607.6.10.30.0.2690
Forced Switch Request
NOTIFICATION-TYPE    

lockoutSwitchRequest 1.3.6.1.4.1.3607.6.10.30.0.2700
Lockout Switch Request
NOTIFICATION-TYPE    

rmonHistoriesAndAlarmsResetReboot 1.3.6.1.4.1.3607.6.10.30.0.2710
RMON Histories And Alarms Reset Reboot
NOTIFICATION-TYPE    

rmonThresholdCrossingAlarm 1.3.6.1.4.1.3607.6.10.30.0.2720
Crossing of Falling/Rising Threshold detected
NOTIFICATION-TYPE    

alarmsSuppressedByUserCommand 1.3.6.1.4.1.3607.6.10.30.0.2730
Alarms Suppressed By User Command
NOTIFICATION-TYPE    

alarmsSuppressedForMaintenance 1.3.6.1.4.1.3607.6.10.30.0.2740
Alarms Suppressed For Maintenance
NOTIFICATION-TYPE    

switchingMatrixModuleFailure 1.3.6.1.4.1.3607.6.10.30.0.2750
Switching Matrix Module Failure
NOTIFICATION-TYPE    

lanConnectionPolarityReversed 1.3.6.1.4.1.3607.6.10.30.0.2760
Lan Connection Polarity Reversed
NOTIFICATION-TYPE    

autonomousPMReportMessageInhibited 1.3.6.1.4.1.3607.6.10.30.0.2780
Autonomous PM Report Message Inhibited
NOTIFICATION-TYPE    

ioSlotToXCONCommunicationFailure 1.3.6.1.4.1.3607.6.10.30.0.2790
IO Slot To XCON Communication Failure
NOTIFICATION-TYPE    

stsPathTraceIdentifierMismatch 1.3.6.1.4.1.3607.6.10.30.0.2800
STS Path Trace Identifier Mismatch
NOTIFICATION-TYPE    

nePowerFailureAtConnectorA 1.3.6.1.4.1.3607.6.10.30.0.2810
NE Power Failure At Connector A
NOTIFICATION-TYPE    

nePowerFailureAtConnectorB 1.3.6.1.4.1.3607.6.10.30.0.2820
NE Power Failure At Connector B
NOTIFICATION-TYPE    

freeMemoryOnCardVeryLow 1.3.6.1.4.1.3607.6.10.30.0.2830
Free memory on the card is very low
NOTIFICATION-TYPE    

freeMemoryOnCardNearZero 1.3.6.1.4.1.3607.6.10.30.0.2840
Free memory on the card is near zero
NOTIFICATION-TYPE    

exerciseRequestOnRing 1.3.6.1.4.1.3607.6.10.30.0.2850
Exercise Request on Ring
NOTIFICATION-TYPE    

exerciseRequestOnSpan 1.3.6.1.4.1.3607.6.10.30.0.2860
Exercise Request on Span
NOTIFICATION-TYPE    

squelchingPath 1.3.6.1.4.1.3607.6.10.30.0.2870
Squelching Path
NOTIFICATION-TYPE    

extraTrafficPreempted 1.3.6.1.4.1.3607.6.10.30.0.2880
Extra Traffic Preempted.
NOTIFICATION-TYPE    

farEndLockoutOfWorkingRing 1.3.6.1.4.1.3607.6.10.30.0.2890
Far End Lockout of working - Ring.
NOTIFICATION-TYPE    

farEndLockoutOfWorkingSpan 1.3.6.1.4.1.3607.6.10.30.0.2900
Far End Lockout of working - Span.
NOTIFICATION-TYPE    

farEndLockoutOfProtectionRing 1.3.6.1.4.1.3607.6.10.30.0.2910
Far End Lockout of Protection - Ring.
NOTIFICATION-TYPE    

farEndLockoutOfProtectionAllSpans 1.3.6.1.4.1.3607.6.10.30.0.2920
Far End Lockout of Protection - All Spans.
NOTIFICATION-TYPE    

farEndWorkingFacilityForcedToSwitchToProtectionRing 1.3.6.1.4.1.3607.6.10.30.0.2930
Far End Working Facility Forced To Switch To Protection - Ring
NOTIFICATION-TYPE    

farEndWorkingFacilityForcedToSwitchToProtectionSpan 1.3.6.1.4.1.3607.6.10.30.0.2940
Far End Working Facility Forced To Switch To Protection - Span
NOTIFICATION-TYPE    

farEndManualSwitchOfWorkingFacilityToProtectionRing 1.3.6.1.4.1.3607.6.10.30.0.2950
Far End Manual Switch Of Working Facility To Protection - Ring
NOTIFICATION-TYPE    

farEndManualSwitchOfWorkingFacilityToProtectionSpan 1.3.6.1.4.1.3607.6.10.30.0.2960
Far End Manual Switch Of Working Facility To Protection - Span
NOTIFICATION-TYPE    

farEndExercisingRing 1.3.6.1.4.1.3607.6.10.30.0.2970
Far End Exercising Ring
NOTIFICATION-TYPE    

farEndExercisingSpan 1.3.6.1.4.1.3607.6.10.30.0.2980
Far End Exercising Span
NOTIFICATION-TYPE    

farEndBERThresholdPassedForSignalFailureRing 1.3.6.1.4.1.3607.6.10.30.0.2990
Far End BER threshold passed for Signal Failure - Ring.
NOTIFICATION-TYPE    

farEndBERThresholdPassedForSignalFailureSpan 1.3.6.1.4.1.3607.6.10.30.0.3000
Far End BER threshold passed for Signal Failure - Span.
NOTIFICATION-TYPE    

farEndBERThresholdPassedForSignalDegradeRing 1.3.6.1.4.1.3607.6.10.30.0.3010
Far End BER threshold passed for Signal Degrade - Ring.
NOTIFICATION-TYPE    

farEndBERThresholdPassedForSignalDegradeSpan 1.3.6.1.4.1.3607.6.10.30.0.3020
Far End BER threshold passed for Signal Degrade - Span.
NOTIFICATION-TYPE    

apsChannelFarEndProtectionLineSignalDegrade 1.3.6.1.4.1.3607.6.10.30.0.3030
APS Channel - Far End Protection Line Signal Degrade
NOTIFICATION-TYPE    

ringSwitchIsActiveOnTheEastSide 1.3.6.1.4.1.3607.6.10.30.0.3040
Ring Switch is active on the East Side.
NOTIFICATION-TYPE    

ringSwitchIsActiveOnTheWestSide 1.3.6.1.4.1.3607.6.10.30.0.3050
Ring Switch is active on the West Side.
NOTIFICATION-TYPE    

spanSwitchIsActiveOnTheEastSide 1.3.6.1.4.1.3607.6.10.30.0.3060
Span Switch is active on the East Side.
NOTIFICATION-TYPE    

spanSwitchIsActiveOnTheWestSide 1.3.6.1.4.1.3607.6.10.30.0.3070
Span Switch is active on the West Side.
NOTIFICATION-TYPE    

uniDirectionalFullPassThroughIsActive 1.3.6.1.4.1.3607.6.10.30.0.3080
Uni-directional Full Pass Through is active.
NOTIFICATION-TYPE    

biDirectionalFullPassThroughIsActive 1.3.6.1.4.1.3607.6.10.30.0.3090
Bi-directional Full Pass Through is active.
NOTIFICATION-TYPE    

kBytesPassThroughIsActive 1.3.6.1.4.1.3607.6.10.30.0.3100
K Bytes Pass Through Is Active
NOTIFICATION-TYPE    

ringIsSegmented 1.3.6.1.4.1.3607.6.10.30.0.3110
Ring is Segmented.
NOTIFICATION-TYPE    

ringTopologyIsUnderConstruction 1.3.6.1.4.1.3607.6.10.30.0.3120
Ring Topology is under construction.
NOTIFICATION-TYPE    

lockoutOfProtectionAllSpans 1.3.6.1.4.1.3607.6.10.30.0.3130
Lockout of Protection - All Spans.
NOTIFICATION-TYPE    

farEndOfFiberIsProvisionedWithDifferentRingID 1.3.6.1.4.1.3607.6.10.30.0.3140
Far end of fiber is provisioned with different ring ID
NOTIFICATION-TYPE    

bothEndsOfFiberProvisionedAsEastOrBothAsWest 1.3.6.1.4.1.3607.6.10.30.0.3150
Both ends of fiber provisioned as East, or both as West
NOTIFICATION-TYPE    

securityInvalidLoginUsernameSeeAuditTrail 1.3.6.1.4.1.3607.6.10.30.0.3160
Security: invalid login (see Audit Trail)
NOTIFICATION-TYPE    

autonomousMessagesInhibited 1.3.6.1.4.1.3607.6.10.30.0.3170
Autonomous messages inhibited
NOTIFICATION-TYPE    

trafficStormOnLANLANTemporarilyDisabled 1.3.6.1.4.1.3607.6.10.30.0.3180
Traffic Storm On LAN. LAN Temporarily Disabled
NOTIFICATION-TYPE    

reptdbchgMessagesInhibited 1.3.6.1.4.1.3607.6.10.30.0.3190
REPT^DBCHG Messages Inhibited
NOTIFICATION-TYPE    

securityUserIDHasExpired 1.3.6.1.4.1.3607.6.10.30.0.3200
Security: User ID Has Expired
NOTIFICATION-TYPE    

partialFanFailure 1.3.6.1.4.1.3607.6.10.30.0.3210
Partial Fan Failure
NOTIFICATION-TYPE    

forcedSwitchRequestOnRing 1.3.6.1.4.1.3607.6.10.30.0.3220
Forced Switch Request On Ring
NOTIFICATION-TYPE    

forcedSwitchRequestOnSpan 1.3.6.1.4.1.3607.6.10.30.0.3230
Forced Switch Request On Span
NOTIFICATION-TYPE    

lockoutSwitchRequestOnRing 1.3.6.1.4.1.3607.6.10.30.0.3240
Lockout switch request on Ring
NOTIFICATION-TYPE    

lockoutSwitchRequestOnSpan 1.3.6.1.4.1.3607.6.10.30.0.3250
Lockout switch request on Span
NOTIFICATION-TYPE    

manualSwitchRequestOnRing 1.3.6.1.4.1.3607.6.10.30.0.3260
Manual switch request on Ring
NOTIFICATION-TYPE    

manualSwitchRequestOnSpan 1.3.6.1.4.1.3607.6.10.30.0.3270
Manual switch request on Span
NOTIFICATION-TYPE    

communicationFailurePeerToPeerSlotControlBusA 1.3.6.1.4.1.3607.6.10.30.0.3280
Peer to Peer Slot communication failure - Control Bus A
NOTIFICATION-TYPE    

communicationFailurePeerToPeerSlotControlBusB 1.3.6.1.4.1.3607.6.10.30.0.3290
Peer to Peer Slot communication failure - Control Bus B
NOTIFICATION-TYPE    

controllerAToShelfSlotCommunicationFailure 1.3.6.1.4.1.3607.6.10.30.0.3300
Controller A to shelf slot communication failure
NOTIFICATION-TYPE    

controllerBToShelfSlotCommunicationFailure 1.3.6.1.4.1.3607.6.10.30.0.3310
Controller B to shelf slot communication failure
NOTIFICATION-TYPE    

interconnectionEquipmentFailureWorkingPayloadBus 1.3.6.1.4.1.3607.6.10.30.0.3320
Interconnection Equipment Failure - Working Payload Bus
NOTIFICATION-TYPE    

interconnectionEquipmentFailureProtectPayloadBus 1.3.6.1.4.1.3607.6.10.30.0.3330
Interconnection Equipment Failure - Protect Payload Bus
NOTIFICATION-TYPE    

inhibitSwitchToProtectRequestOnEquipment 1.3.6.1.4.1.3607.6.10.30.0.3340
Inhibit Switch to Protect Request on equipment
NOTIFICATION-TYPE    

inhibitSwitchToWorkingRequestOnEquipment 1.3.6.1.4.1.3607.6.10.30.0.3350
Inhibit Switch to Working Request on equipment
NOTIFICATION-TYPE    

berThresholdExceededForSignalDegradeLine 1.3.6.1.4.1.3607.6.10.30.0.3360
BER Threshold exceeded for Signal Degrade - Line
NOTIFICATION-TYPE    

berThresholdExceededForSignalDegradePath 1.3.6.1.4.1.3607.6.10.30.0.3370
BER Threshold exceeded for Signal Degrade - Path
NOTIFICATION-TYPE    

berThresholdExceededForSignalFailureLine 1.3.6.1.4.1.3607.6.10.30.0.3380
BER Threshold Exceeded For Signal Failure - Line
NOTIFICATION-TYPE    

berThresholdExceededForSignalFailurePath 1.3.6.1.4.1.3607.6.10.30.0.3390
BER Threshold Exceeded For Signal Failure - Path
NOTIFICATION-TYPE    

exercisingRingSuccessfully 1.3.6.1.4.1.3607.6.10.30.0.3400
Exercising Ring Successfully
NOTIFICATION-TYPE    

exercisingSpanSuccessfully 1.3.6.1.4.1.3607.6.10.30.0.3410
Exercising Span Successfully
NOTIFICATION-TYPE    

spanIsInWaitToRestoreState 1.3.6.1.4.1.3607.6.10.30.0.3420
Span is in Wait To Restore state
NOTIFICATION-TYPE    

exerciseRequestOnRingFailed 1.3.6.1.4.1.3607.6.10.30.0.3430
Exercise Request on Ring Failed
NOTIFICATION-TYPE    

exerciseRequestOnSpanFailed 1.3.6.1.4.1.3607.6.10.30.0.3440
Exercise Request on Span Failed
NOTIFICATION-TYPE    

farEndLockoutOfProtectionSpan 1.3.6.1.4.1.3607.6.10.30.0.3450
Far End Lockout Of Protection - Span
NOTIFICATION-TYPE    

manufacturingDataMemoryEEPROMFailure 1.3.6.1.4.1.3607.6.10.30.0.3460
Manufacturing Data Memory (EEPROM) Failure
NOTIFICATION-TYPE    

replaceableEquipmentOrUnitIsMissing 1.3.6.1.4.1.3607.6.10.30.0.3470
Replaceable Equipment/Unit is Missing
NOTIFICATION-TYPE    

softwareDownloadFailed 1.3.6.1.4.1.3607.6.10.30.0.3480
Software Download Failed
NOTIFICATION-TYPE    

extraTrafficPCADropped 1.3.6.1.4.1.3607.6.10.30.0.3490
Extra Traffic (PCA) Dropped
NOTIFICATION-TYPE    

etherTxOversubscribed 1.3.6.1.4.1.3607.6.10.30.0.3500
Ether tx oversubscribed
NOTIFICATION-TYPE    

etherRxOverSubscribed 1.3.6.1.4.1.3607.6.10.30.0.3510
Ether rx over subscribed
NOTIFICATION-TYPE    

etherTxExcessFlowCtrl 1.3.6.1.4.1.3607.6.10.30.0.3520
Ether tx excess flow ctrl
NOTIFICATION-TYPE    

etherRxExcessFlowCtrl 1.3.6.1.4.1.3607.6.10.30.0.3530
Ether rx excess flow ctrl
NOTIFICATION-TYPE    

transportLayerFailure 1.3.6.1.4.1.3607.6.10.30.0.3540
transport layer failure
NOTIFICATION-TYPE    

etherTxUnderrun 1.3.6.1.4.1.3607.6.10.30.0.3550
Ether tx underrun
NOTIFICATION-TYPE    

synchronizationReferenceFrequencyOutOfBounds 1.3.6.1.4.1.3607.6.10.30.0.3560
Synchronization reference frequency out of bounds.
NOTIFICATION-TYPE    

ntpOrSntpHostFailure 1.3.6.1.4.1.3607.6.10.30.0.3570
NTP/SNTP Host Failure.
NOTIFICATION-TYPE    

peerCardNotResponding 1.3.6.1.4.1.3607.6.10.30.0.3580
Peer Card Not Responding
NOTIFICATION-TYPE    

alarmsAndEventsSuppressedForThisObject 1.3.6.1.4.1.3607.6.10.30.0.3590
Alarms and events suppressed for this object
NOTIFICATION-TYPE    

ds3FrameFormatMismatch 1.3.6.1.4.1.3607.6.10.30.0.3600
DS3 Frame Format Mismatch
NOTIFICATION-TYPE    

waitToRestore 1.3.6.1.4.1.3607.6.10.30.0.3610
Wait To Restore
NOTIFICATION-TYPE    

extremeHighVoltBatteryA 1.3.6.1.4.1.3607.6.10.30.0.3620
Extreme High Volt Battery A
NOTIFICATION-TYPE    

extremeLowVoltBatteryA 1.3.6.1.4.1.3607.6.10.30.0.3630
Extreme Low Volt Battery A
NOTIFICATION-TYPE    

extremeHighVoltBatteryB 1.3.6.1.4.1.3607.6.10.30.0.3640
Extreme High Volt Battery B
NOTIFICATION-TYPE    

extremeLowVoltBatteryB 1.3.6.1.4.1.3607.6.10.30.0.3650
Extreme Low Volt Battery B
NOTIFICATION-TYPE    

iosConfigCopyFailed 1.3.6.1.4.1.3607.6.10.30.0.3660
IOS config copy failed
NOTIFICATION-TYPE    

iosConfigCopyInProgress 1.3.6.1.4.1.3607.6.10.30.0.3670
IOS config copy in progress
NOTIFICATION-TYPE    

iosConfigCopySuccess 1.3.6.1.4.1.3607.6.10.30.0.3680
IOS Config Copy Success
NOTIFICATION-TYPE    

signalingUnableToSetupCircuit 1.3.6.1.4.1.3607.6.10.30.0.3710
Signaling Unable to setup circuit
NOTIFICATION-TYPE    

errorInStartupConfig 1.3.6.1.4.1.3607.6.10.30.0.3712
Error in Startup Config
NOTIFICATION-TYPE    

noStartupConfig 1.3.6.1.4.1.3607.6.10.30.0.3714
No Startup Config
NOTIFICATION-TYPE    

needToSaveRunningConfig 1.3.6.1.4.1.3607.6.10.30.0.3716
Need to Save Running Config
NOTIFICATION-TYPE    

invalidAlarm 1.3.6.1.4.1.3607.6.10.30.0.3718
Invalid Alarm
NOTIFICATION-TYPE    

rsvpHelloFSMToNeighborDown 1.3.6.1.4.1.3607.6.10.30.0.3720
RSVP Hello FSM to Neighbor down
NOTIFICATION-TYPE    

securityInvalidLoginUsername 1.3.6.1.4.1.3607.6.10.30.0.3722
Security: Invalid Login - Username - See Audit Log
NOTIFICATION-TYPE    

databaseBackupFailed 1.3.6.1.4.1.3607.6.10.30.0.3724
Database Backup Failed
NOTIFICATION-TYPE    

databaseRestoreFailed 1.3.6.1.4.1.3607.6.10.30.0.3726
Database Restore Failed
NOTIFICATION-TYPE    

lmpHelloFSMToControlChannelDown 1.3.6.1.4.1.3607.6.10.30.0.3730
LMP Hello FSM to Control Channel down
NOTIFICATION-TYPE    

lmpNeighborDiscoveryHasFailed 1.3.6.1.4.1.3607.6.10.30.0.3740
LMP Neighbor Discovery has failed
NOTIFICATION-TYPE    

unauthorizedIncomingSignalingRequest 1.3.6.1.4.1.3607.6.10.30.0.3750
Unauthorized incoming signaling request
NOTIFICATION-TYPE    

auditLog80PercentFull 1.3.6.1.4.1.3607.6.10.30.0.3760
Audit Log 80 Percent Full
NOTIFICATION-TYPE    

moduleCommunicationFailure 1.3.6.1.4.1.3607.6.10.30.0.3762
Module Communication Failure
NOTIFICATION-TYPE    

auditLog100PercentFullOldestRecordsWillBeLost 1.3.6.1.4.1.3607.6.10.30.0.3764
Audit Log 100 Percent Full - Oldest records will be lost
NOTIFICATION-TYPE    

standbyDatabaseOutOfSync 1.3.6.1.4.1.3607.6.10.30.0.3766
Standby Database Out of Sync
NOTIFICATION-TYPE    

redundantPowerCapabilityLost 1.3.6.1.4.1.3607.6.10.30.0.3768
Redundant Power Capability Lost
NOTIFICATION-TYPE    

forcedSwitchToPrimaryReference 1.3.6.1.4.1.3607.6.10.30.0.3770
Forced Switch To Primary Reference
NOTIFICATION-TYPE    

forcedSwitchToSecondReference 1.3.6.1.4.1.3607.6.10.30.0.3780
Forced Switch To Second Reference
NOTIFICATION-TYPE    

forcedSwitchToThirdReference 1.3.6.1.4.1.3607.6.10.30.0.3790
Forced Switch To Third Reference
NOTIFICATION-TYPE    

forcedSwitchToInternalClock 1.3.6.1.4.1.3607.6.10.30.0.3800
Forced Switch To Internal Clock
NOTIFICATION-TYPE    

industrialHighTemperature 1.3.6.1.4.1.3607.6.10.30.0.3805
Industrial High Temperature
NOTIFICATION-TYPE    

timSectionTraceIdentifierMismatchFailure 1.3.6.1.4.1.3607.6.10.30.0.4000
TIM Section - Trace Identifier Mismatch Failure.
NOTIFICATION-TYPE    

aisMultiplexSectionAlarmIndicationSignal 1.3.6.1.4.1.3607.6.10.30.0.4010
AIS - Multiplex Section - Alarm Indication Signal
NOTIFICATION-TYPE    

rdiMultiplexSectionRemoteDefectOrAlarmIndication 1.3.6.1.4.1.3607.6.10.30.0.4020
RDI - Multiplex Section - Remote Defect/Alarm Indication
NOTIFICATION-TYPE    

timHighOrderTraceIdentifierMismatchFailure 1.3.6.1.4.1.3607.6.10.30.0.4030
TIM High Order - Trace Identifier Mismatch Failure
NOTIFICATION-TYPE    

aisAdministrationUnitAlarmIndicationSignal 1.3.6.1.4.1.3607.6.10.30.0.4040
AIS - Administration Unit - Alarm Indication Signal
NOTIFICATION-TYPE    

lopAdministrationUnitLossOfPointer 1.3.6.1.4.1.3607.6.10.30.0.4050
LOP - Administration Unit - Loss of Pointer
NOTIFICATION-TYPE    

slmfUnequippedHighOrderPathUnequipped 1.3.6.1.4.1.3607.6.10.30.0.4060
SLMF - Unequipped High Order - Path Unequipped
NOTIFICATION-TYPE    

slmfPLMHighOrderPathLabelMismatch 1.3.6.1.4.1.3607.6.10.30.0.4070
SLMF - PLM High Order - Path Label Mismatch
NOTIFICATION-TYPE    

rdiHighOrderRemoteDefectOrAlarmIndication 1.3.6.1.4.1.3607.6.10.30.0.4080
RDI - High Order - Remote Defect/Alarm Indication
NOTIFICATION-TYPE    

lopTributaryUnitLossOfPointer 1.3.6.1.4.1.3607.6.10.30.0.4090
LOP - Tributary Unit - Loss of Pointer
NOTIFICATION-TYPE    

aisTributaryUnitAlarmIndicationSignal 1.3.6.1.4.1.3607.6.10.30.0.4100
AIS - Tributary Unit - Alarm Indication Signal
NOTIFICATION-TYPE    

slmfUnequippedLowOrderPathUnequipped 1.3.6.1.4.1.3607.6.10.30.0.4110
SLMF - Unequipped Low Order - Path Unequipped
NOTIFICATION-TYPE    

slmfPLMLowOrderPathLabelMismatch 1.3.6.1.4.1.3607.6.10.30.0.4120
SLMF - PLM Low Order - Path Label Mismatch
NOTIFICATION-TYPE    

timLowOrderTraceIdentifierMismatchFailure 1.3.6.1.4.1.3607.6.10.30.0.4130
TIM Low Order - Trace Identifier Mismatch Failure
NOTIFICATION-TYPE    

rfiLowOrderRemoteFailureOrAlarmIndication 1.3.6.1.4.1.3607.6.10.30.0.4140
RFI - Low Order - Remote Failure/Alarm Indication
NOTIFICATION-TYPE    

g811PrimaryReferenceClockTraceable 1.3.6.1.4.1.3607.6.10.30.0.4150
G811 - Primary Reference Clock traceable.
NOTIFICATION-TYPE    

g812TransitNodeClockTraceable 1.3.6.1.4.1.3607.6.10.30.0.4160
G812 - Transit Node Clock traceable.
NOTIFICATION-TYPE    

g812LocalNodeClockTraceable 1.3.6.1.4.1.3607.6.10.30.0.4170
G812 - Local Node Clock traceable.
NOTIFICATION-TYPE    

g813SynchronousEquipmentTimingSourceTraceable 1.3.6.1.4.1.3607.6.10.30.0.4180
G813 - Synchronous Equipment Timing Source traceable
NOTIFICATION-TYPE    

e1LoopbackDueToFEACCommand 1.3.6.1.4.1.3607.6.10.30.0.4190
E1 loopback due to FEAC command
NOTIFICATION-TYPE    

e1LoopbackCommandSentToFarEnd 1.3.6.1.4.1.3607.6.10.30.0.4200
E1 loopback command sent to Far End
NOTIFICATION-TYPE    

e3LoopbackDueToFEACCommand 1.3.6.1.4.1.3607.6.10.30.0.4210
E3 loopback due to FEAC command
NOTIFICATION-TYPE    

farEndMultipleE1LOSDetectedOnE3 1.3.6.1.4.1.3607.6.10.30.0.4220
far end Multiple E1 LOS detected on E3
NOTIFICATION-TYPE    

farEndE1EqptFailNonServiceAffecting 1.3.6.1.4.1.3607.6.10.30.0.4230
far end E1 eqpt fail non service affecting
NOTIFICATION-TYPE    

farEndE1EqptFailServiceAffecting 1.3.6.1.4.1.3607.6.10.30.0.4240
far end E1 eqpt fail service affecting
NOTIFICATION-TYPE    

farEndSingleE1LOS 1.3.6.1.4.1.3607.6.10.30.0.4250
far end Single E1 LOS
NOTIFICATION-TYPE    

farEndE3EqptFailServiceAffecting 1.3.6.1.4.1.3607.6.10.30.0.4260
far end E3 eqpt fail service affecting
NOTIFICATION-TYPE    

e3LoopbackCommandSentToFarEnd 1.3.6.1.4.1.3607.6.10.30.0.4270
E3 loopback command sent to far end
NOTIFICATION-TYPE    

farEndE3EqptFailNonServiceAffecting 1.3.6.1.4.1.3607.6.10.30.0.4280
far end E3 eqpt fail non service affecting
NOTIFICATION-TYPE    

lowVoltBatteryA 1.3.6.1.4.1.3607.6.10.30.0.4290
Low Volt - Battery A
NOTIFICATION-TYPE    

highVoltBatteryA 1.3.6.1.4.1.3607.6.10.30.0.4300
High Volt - Battery A
NOTIFICATION-TYPE    

lowVoltBatteryB 1.3.6.1.4.1.3607.6.10.30.0.4310
Low Volt - Battery B
NOTIFICATION-TYPE    

highVoltBatteryB 1.3.6.1.4.1.3607.6.10.30.0.4320
High Volt - Battery B
NOTIFICATION-TYPE    

msspRingOutOfSync 1.3.6.1.4.1.3607.6.10.30.0.4330
MS-SP ring out of sync
NOTIFICATION-TYPE    

msspMultiNodeTableUpdateCompleted 1.3.6.1.4.1.3607.6.10.30.0.4340
MSSP Multi-Node Table Update Completed
NOTIFICATION-TYPE    

automaticSNCPSwitchCausedByAIS 1.3.6.1.4.1.3607.6.10.30.0.4350
automatic SNCP switch caused by AIS
NOTIFICATION-TYPE    

automaticSNCPSwitchCausedByLOP 1.3.6.1.4.1.3607.6.10.30.0.4360
automatic SNCP switch caused by Lop
NOTIFICATION-TYPE    

automaticSNCPSwitchCausedByUNEQ 1.3.6.1.4.1.3607.6.10.30.0.4370
Automatic SNCP Switch caused by UNEQ
NOTIFICATION-TYPE    

automaticSNCPSwitchCausedByPDI 1.3.6.1.4.1.3607.6.10.30.0.4380
automatic SNCP switch caused by PDI
NOTIFICATION-TYPE    

automaticSNCPSwitchCausedBySFBER 1.3.6.1.4.1.3607.6.10.30.0.4390
Automatic SNCP Switch caused by SFBER
NOTIFICATION-TYPE    

automaticSNCPSwitchCausedBySDBER 1.3.6.1.4.1.3607.6.10.30.0.4400
Automatic SNCP Switch caused by SDBER
NOTIFICATION-TYPE    

stmConcatenationError 1.3.6.1.4.1.3607.6.10.30.0.4410
STM Concatenation error
NOTIFICATION-TYPE    

e3IdleCondition 1.3.6.1.4.1.3607.6.10.30.0.4420
E3 Idle Condition
NOTIFICATION-TYPE    

channelMSSPInconsistentAPSCode 1.3.6.1.4.1.3607.6.10.30.0.4430
channel MSSP inconsistent APS code
NOTIFICATION-TYPE    

channelMSSPImproperAPSCodeAPS 1.3.6.1.4.1.3607.6.10.30.0.4440
channel MSSP Improper APS code APS
NOTIFICATION-TYPE    

channelMSSPNodeIdMismatchAPS 1.3.6.1.4.1.3607.6.10.30.0.4450
channel MSSP Node Id Mismatch APS
NOTIFICATION-TYPE    

channelMSSPDefaultKAPS 1.3.6.1.4.1.3607.6.10.30.0.4460
channel MSSP Default K APS
NOTIFICATION-TYPE    

channelMSSPConnectionLossAPS 1.3.6.1.4.1.3607.6.10.30.0.4470
channel MSSP Connection loss APS
NOTIFICATION-TYPE    

minimumClockTraceableSDH 1.3.6.1.4.1.3607.6.10.30.0.4480
SDH Minimum clock Traceable
NOTIFICATION-TYPE    

lineIsInWaitToRestoreStateSDH 1.3.6.1.4.1.3607.6.10.30.0.4490
SDH line is in Wait To Restore state
NOTIFICATION-TYPE    

berThresholdExceededForSignalDegradeHighOrder 1.3.6.1.4.1.3607.6.10.30.0.4500
BER Threshold Exceeded For Signal Degrade - High Order
NOTIFICATION-TYPE    

berThresholdExceededForSignalFailureHighOrder 1.3.6.1.4.1.3607.6.10.30.0.4510
BER Threshold Exceeded For Signal Failure - High Order
NOTIFICATION-TYPE    

berThresholdExceededForSignalDegradeLowOrder 1.3.6.1.4.1.3607.6.10.30.0.4520
BER Threshold Exceeded For Signal Degrade - Low Order
NOTIFICATION-TYPE    

berThresholdExceededForSignalFailureLowOrder 1.3.6.1.4.1.3607.6.10.30.0.4530
BER Threshold Exceeded For Signal Failure - Low Order
NOTIFICATION-TYPE    

failureToSwitchToProtectionHighOrderPath 1.3.6.1.4.1.3607.6.10.30.0.4540
Failure To Switch To Protection - High Order Path
NOTIFICATION-TYPE    

failureToSwitchToProtectionLowOrderPath 1.3.6.1.4.1.3607.6.10.30.0.4550
Failure To Switch To Protection - Low Order Path
NOTIFICATION-TYPE    

lofAdministrationUnitLossOfMultiFrame 1.3.6.1.4.1.3607.6.10.30.0.4560
LOF - Administration Unit - Loss of Multi Frame
NOTIFICATION-TYPE    

sdhSpanIsInWaitToRestoreState 1.3.6.1.4.1.3607.6.10.30.0.4570
SDH span is in Wait To Restore state
NOTIFICATION-TYPE    

a8b10bOutOfSync 1.3.6.1.4.1.3607.6.10.30.0.4755
8B10B Out of Sync
NOTIFICATION-TYPE    

odukPMAlarmIndicationSignal 1.3.6.1.4.1.3607.6.10.30.0.4760
ODUk: PM Alarm Indication Signal
NOTIFICATION-TYPE    

otukAlarmIndicationSignal 1.3.6.1.4.1.3607.6.10.30.0.4765
OTUk: Alarm Indication Signal
NOTIFICATION-TYPE    

otukSMBackwardDefectIndication 1.3.6.1.4.1.3607.6.10.30.0.4770
OTUk: Backward Defect Indication
NOTIFICATION-TYPE    

odukBackwardDefectIndication 1.3.6.1.4.1.3607.6.10.30.0.4775
ODUk: Backward Defect Indication
NOTIFICATION-TYPE    

fecUncorrectedWord 1.3.6.1.4.1.3607.6.10.30.0.4780
FEC Uncorrected Word
NOTIFICATION-TYPE    

gccTerminationFailure 1.3.6.1.4.1.3607.6.10.30.0.4785
GCC Termination Failure
NOTIFICATION-TYPE    

otukIncomingAlignmentError 1.3.6.1.4.1.3607.6.10.30.0.4790
OTUk: Incoming Alignment Error
NOTIFICATION-TYPE    

odukLockedDefectPM 1.3.6.1.4.1.3607.6.10.30.0.4795
ODUk: Locked Defect - PM
NOTIFICATION-TYPE    

lossOfMultiFrame 1.3.6.1.4.1.3607.6.10.30.0.4800
Loss of Multi-Frame
NOTIFICATION-TYPE    

odukOpenConnectionIndication 1.3.6.1.4.1.3607.6.10.30.0.4805
ODUk: Open Connection Indication
NOTIFICATION-TYPE    

payloadTypeIdentifierMismatch 1.3.6.1.4.1.3607.6.10.30.0.4810
Payload Type Identifier Mismatch
NOTIFICATION-TYPE    

odukTrailTraceIdentifierMismatch 1.3.6.1.4.1.3607.6.10.30.0.4815
ODUk: Trail Trace Identifier Mismatch
NOTIFICATION-TYPE    

otukTrailTraceIdentifierMismatch 1.3.6.1.4.1.3607.6.10.30.0.4820
OTUk: Trail Trace Identifier Mismatch
NOTIFICATION-TYPE    

equipmentHighLaserBias 1.3.6.1.4.1.3607.6.10.30.0.4825
Equipment High Laser Bias
NOTIFICATION-TYPE    

equipmentHighLaserTemp 1.3.6.1.4.1.3607.6.10.30.0.4830
Equipment High Laser Temp
NOTIFICATION-TYPE    

equipmentHighLaserPeltier 1.3.6.1.4.1.3607.6.10.30.0.4835
Equipment High Laser Peltier
NOTIFICATION-TYPE    

facilityHighRxPower 1.3.6.1.4.1.3607.6.10.30.0.4840
Facility High Rx power
NOTIFICATION-TYPE    

equipmentHighTxPower 1.3.6.1.4.1.3607.6.10.30.0.4845
Equipment High Tx power
NOTIFICATION-TYPE    

equipmentHighTransceiverVoltage 1.3.6.1.4.1.3607.6.10.30.0.4850
Equipment High Transceiver voltage
NOTIFICATION-TYPE    

equipmentLowLaserBias 1.3.6.1.4.1.3607.6.10.30.0.4855
Equipment Low Laser Bias
NOTIFICATION-TYPE    

equipmentLowLaserTemp 1.3.6.1.4.1.3607.6.10.30.0.4860
Equipment Low Laser Temp
NOTIFICATION-TYPE    

equipmentLowLaserPeltier 1.3.6.1.4.1.3607.6.10.30.0.4865
Equipment Low Laser Peltier
NOTIFICATION-TYPE    

facilityLowRxPower 1.3.6.1.4.1.3607.6.10.30.0.4870
Facility Low Rx power
NOTIFICATION-TYPE    

equipmentLowTxPower 1.3.6.1.4.1.3607.6.10.30.0.4875
Equipment Low Tx power
NOTIFICATION-TYPE    

equipmentLowTransceiverVoltage 1.3.6.1.4.1.3607.6.10.30.0.4880
Equipment Low Transceiver voltage
NOTIFICATION-TYPE    

equipmentRxLocked 1.3.6.1.4.1.3607.6.10.30.0.4885
Equipment Rx Locked
NOTIFICATION-TYPE    

equipmentSquelched 1.3.6.1.4.1.3607.6.10.30.0.4890
Equipment Squelched
NOTIFICATION-TYPE    

equipmentTxLocked 1.3.6.1.4.1.3607.6.10.30.0.4895
Equipment Tx Locked
NOTIFICATION-TYPE    

otukSignalFailure 1.3.6.1.4.1.3607.6.10.30.0.4900
OTUK Signal Failure
NOTIFICATION-TYPE    

odukSignalFailure 1.3.6.1.4.1.3607.6.10.30.0.4905
ODUK Signal Failure
NOTIFICATION-TYPE    

otukSignalDegrade 1.3.6.1.4.1.3607.6.10.30.0.4910
OTUK Signal Degrade
NOTIFICATION-TYPE    

odukSignalDegrade 1.3.6.1.4.1.3607.6.10.30.0.4915
ODUK Signal Degrade
NOTIFICATION-TYPE    

pluggablePortMissing 1.3.6.1.4.1.3607.6.10.30.0.4920
Pluggable Port missing
NOTIFICATION-TYPE    

pluggablePortRateMismatch 1.3.6.1.4.1.3607.6.10.30.0.4925
Pluggable Port rate mismatch
NOTIFICATION-TYPE    

pluggablePortSecurityCodeMismatch 1.3.6.1.4.1.3607.6.10.30.0.4930
Pluggable Port security code mismatch
NOTIFICATION-TYPE    

tciNotSelected 1.3.6.1.4.1.3607.6.10.30.0.4935
Tci not selected
NOTIFICATION-TYPE    

tci1ClockFailure 1.3.6.1.4.1.3607.6.10.30.0.4940
Tci 1 Clock Failure
NOTIFICATION-TYPE    

odukPMBackwardDefectIndication 1.3.6.1.4.1.3607.6.10.30.0.4945
ODUk: PM Backward Defect Indication
NOTIFICATION-TYPE    

odukTCM1BackwardDefectIndication 1.3.6.1.4.1.3607.6.10.30.0.4950
ODUk: TCM1 Backward Defect Indication
NOTIFICATION-TYPE    

odukTCM2BackwardDefectIndication 1.3.6.1.4.1.3607.6.10.30.0.4955
ODUk: TCM2 Backward Defect Indication
NOTIFICATION-TYPE    

equipmentHighRxTemperature 1.3.6.1.4.1.3607.6.10.30.0.4960
Equipment High Rx temperature
NOTIFICATION-TYPE    

equipmentLowRxTemperature 1.3.6.1.4.1.3607.6.10.30.0.4965
Equipment Low Rx temperature
NOTIFICATION-TYPE    

tci2ClockFailure 1.3.6.1.4.1.3607.6.10.30.0.4970
Tci 2 Clock Failure
NOTIFICATION-TYPE    

equipmentWavelengthMismatch 1.3.6.1.4.1.3607.6.10.30.0.4975
Equipment Wavelength Mismatch
NOTIFICATION-TYPE    

dspCommunicationFailure 1.3.6.1.4.1.3607.6.10.30.0.4980
DSP Communication Failure
NOTIFICATION-TYPE    

dspFailure 1.3.6.1.4.1.3607.6.10.30.0.4985
DSP Failure
NOTIFICATION-TYPE    

laserApproachingEndOfLife 1.3.6.1.4.1.3607.6.10.30.0.5000
Laser Approaching End of Life
NOTIFICATION-TYPE    

crossconnectLoopback 1.3.6.1.4.1.3607.6.10.30.0.5010
Cross-connect Loopback
NOTIFICATION-TYPE    

adminLogoutOfUser 1.3.6.1.4.1.3607.6.10.30.0.5020
Admin Logout of User
NOTIFICATION-TYPE    

userLockedOut 1.3.6.1.4.1.3607.6.10.30.0.5030
User Locked Out
NOTIFICATION-TYPE    

adminLockoutOfUser 1.3.6.1.4.1.3607.6.10.30.0.5040
Admin Lockout of User
NOTIFICATION-TYPE    

adminLockoutClear 1.3.6.1.4.1.3607.6.10.30.0.5050
Admin Lockout Clear
NOTIFICATION-TYPE    

invalidLoginUsername 1.3.6.1.4.1.3607.6.10.30.0.5060
Invalid Login: Username
NOTIFICATION-TYPE    

securityInvalidLoginPassword 1.3.6.1.4.1.3607.6.10.30.0.5070
Security: Invalid Login - Password - See Audit Log
NOTIFICATION-TYPE    

securityInvalidLoginLockedOut 1.3.6.1.4.1.3607.6.10.30.0.5080
Security: Invalid Login - Locked Out - See Audit Log
NOTIFICATION-TYPE    

securityInvalidLoginAlreadyLoggedOn 1.3.6.1.4.1.3607.6.10.30.0.5090
Security: Invalid Login - Already Logged On - See Audit Log
NOTIFICATION-TYPE    

loginOfUser 1.3.6.1.4.1.3607.6.10.30.0.5100
Login of User
NOTIFICATION-TYPE    

automaticLogoutOfIdleUser 1.3.6.1.4.1.3607.6.10.30.0.5110
Automatic Logout of IdleUser
NOTIFICATION-TYPE    

logoutOfUser 1.3.6.1.4.1.3607.6.10.30.0.5120
Logout of User
NOTIFICATION-TYPE    

enhancedRemoteFailureIndicationPathServer 1.3.6.1.4.1.3607.6.10.30.0.5200
Enhanced Remote Failure Indication - Path - Server
NOTIFICATION-TYPE    

enhancedRemoteFailureIndicationPathConnectivity 1.3.6.1.4.1.3607.6.10.30.0.5210
Enhanced Remote Failure Indication - Path - Connectivity
NOTIFICATION-TYPE    

enhancedRemoteFailureIndicationPathPayload 1.3.6.1.4.1.3607.6.10.30.0.5220
Enhanced Remote Failure Indication - Path - Payload
NOTIFICATION-TYPE    

firewallHasBeenDisabled 1.3.6.1.4.1.3607.6.10.30.0.5230
Firewall Has Been Disabled
NOTIFICATION-TYPE    

securityIntrusionDetPwd 1.3.6.1.4.1.3607.6.10.30.0.5240
Security Intrusion Attempt Detected - See Audit Log
NOTIFICATION-TYPE    

securityIntrusionDetUser 1.3.6.1.4.1.3607.6.10.30.0.5250
Security Intrusion Attempt Detected - See Audit Log
NOTIFICATION-TYPE    

connectionEquipmentMismatch 1.3.6.1.4.1.3607.6.10.30.0.5260
Connection Equipment Mismatch
NOTIFICATION-TYPE    

disableInactiveUser 1.3.6.1.4.1.3607.6.10.30.0.5270
Disable Inactive User
NOTIFICATION-TYPE    

disableInactiveClear 1.3.6.1.4.1.3607.6.10.30.0.5280
Disable Inactive Clear
NOTIFICATION-TYPE    

batteryFailure 1.3.6.1.4.1.3607.6.10.30.0.5290
Battery Failure
NOTIFICATION-TYPE    

extremeHighVolt 1.3.6.1.4.1.3607.6.10.30.0.5300
Extreme High Volt
NOTIFICATION-TYPE    

extremeLowVolt 1.3.6.1.4.1.3607.6.10.30.0.5310
Extreme Low Volt
NOTIFICATION-TYPE    

highVolt 1.3.6.1.4.1.3607.6.10.30.0.5320
High Volt
NOTIFICATION-TYPE    

lowVolt 1.3.6.1.4.1.3607.6.10.30.0.5330
Low Volt
NOTIFICATION-TYPE    

suspendUser 1.3.6.1.4.1.3607.6.10.30.0.5340
Suspend User
NOTIFICATION-TYPE    

suspendUserClear 1.3.6.1.4.1.3607.6.10.30.0.5350
Suspend User Clear
NOTIFICATION-TYPE    

lineDccTerminationFailure 1.3.6.1.4.1.3607.6.10.30.0.5360
Line DCC Termination Failure
NOTIFICATION-TYPE    

multiplexSectionDccTerminationFailure 1.3.6.1.4.1.3607.6.10.30.0.5370
Multiplex Section DCC Termination Failure
NOTIFICATION-TYPE    

gigaBitEthernetOutOfSync 1.3.6.1.4.1.3607.6.10.30.0.5380
GigaBit Ethernet Out of Sync
NOTIFICATION-TYPE    

sequenceMismatch 1.3.6.1.4.1.3607.6.10.30.0.5390
Sequence Mismatch
NOTIFICATION-TYPE    

lossOfAlignment 1.3.6.1.4.1.3607.6.10.30.0.5400
Loss of Alignment
NOTIFICATION-TYPE    

outOfUseByAdministrativeCommand 1.3.6.1.4.1.3607.6.10.30.0.5410
Out of Use - Administrative Command
NOTIFICATION-TYPE    

outOfUseTransportFailure 1.3.6.1.4.1.3607.6.10.30.0.5420
Out of Use - Transport Failure
NOTIFICATION-TYPE    

vcatGroupDown 1.3.6.1.4.1.3607.6.10.30.0.5430
VCAT Group Down
NOTIFICATION-TYPE    

vcatGroupDegraded 1.3.6.1.4.1.3607.6.10.30.0.5440
VCAT Group Degraded
NOTIFICATION-TYPE    

vcatGroupIncomplete 1.3.6.1.4.1.3607.6.10.30.0.5450
VCAT Group Incomplete
NOTIFICATION-TYPE    

alarmIndicationSignalInTX 1.3.6.1.4.1.3607.6.10.30.0.5460
Alarm Indication Signal in TX
NOTIFICATION-TYPE    

remoteAlarmIndicationInTX 1.3.6.1.4.1.3607.6.10.30.0.5470
Remote Alarm Indication in TX
NOTIFICATION-TYPE    

kByteAPSChannelFailure 1.3.6.1.4.1.3607.6.10.30.0.5480
Kbyte Channel Failure
NOTIFICATION-TYPE    

apsInvalidMode 1.3.6.1.4.1.3607.6.10.30.0.5490
APS Invalid Mode
NOTIFICATION-TYPE    

ipAddressAlreadyInUseWithinTheSameDccArea 1.3.6.1.4.1.3607.6.10.30.0.5500
IP Address A1ready In Use Within The Same DCC Area
NOTIFICATION-TYPE    

nodeNameInUseWithinTheSameDccArea 1.3.6.1.4.1.3607.6.10.30.0.5510
Node name already in use within the same DCC Area
NOTIFICATION-TYPE    

rearPanelEthernetLinkRemoved 1.3.6.1.4.1.3607.6.10.30.0.5520
Rear Panel Ethernet Link Removed
NOTIFICATION-TYPE    

manualSwitchToProtectResultedInNoTrafficSwitch 1.3.6.1.4.1.3607.6.10.30.0.5530
Manual Switch To Protect Resulted in No Traffic Switch
NOTIFICATION-TYPE    

manualSwitchBackToWorkingResultedInNoTrafficSwitch 1.3.6.1.4.1.3607.6.10.30.0.5540
Manual Switch Back To Working Resulted in No Traffic Switch
NOTIFICATION-TYPE    

forcedSwitchToProtectResultedInNoTrafficSwitch 1.3.6.1.4.1.3607.6.10.30.0.5550
Forced Switch To Protection Resulted in No Traffic Switch
NOTIFICATION-TYPE    

forcedSwitchBackToWorkingResultedInNoTrafficSwitch 1.3.6.1.4.1.3607.6.10.30.0.5560
Forced Switch Back To Working Resulted in No Traffic Switch
NOTIFICATION-TYPE    

duplicateSerialNumberDetectedOnAPluggableEntity 1.3.6.1.4.1.3607.6.10.30.0.5570
Duplicate Serial number detected on a pluggable entity
NOTIFICATION-TYPE    

lossOfSignalForOpticalChannel 1.3.6.1.4.1.3607.6.10.30.0.5600
Incoming Payload Signal Absent
NOTIFICATION-TYPE    

encapsulationMismatchPath 1.3.6.1.4.1.3607.6.10.30.0.5610
Encapsulation Mismatch Path
NOTIFICATION-TYPE    

encapsulationMismatchVT 1.3.6.1.4.1.3607.6.10.30.0.5620
Encapsulation Mismatch - VT
NOTIFICATION-TYPE    

encapsulationMismatchHighOrderPath 1.3.6.1.4.1.3607.6.10.30.0.5630
Encapsulation Mismatch High Order - Path
NOTIFICATION-TYPE    

encapsulationMismatchLowOrderPath 1.3.6.1.4.1.3607.6.10.30.0.5640
Encapsulation Mismatch Low Order - Path
NOTIFICATION-TYPE    

gfpUserPayloadMismatch 1.3.6.1.4.1.3607.6.10.30.0.5650
GFP User Payload Mismatch
NOTIFICATION-TYPE    

gfpFibreChannelDistanceExtensionMismatch 1.3.6.1.4.1.3607.6.10.30.0.5660
GFP Fibre Channel Distance Extension Mismatch
NOTIFICATION-TYPE    

gfpFibreChannelDistanceExtensionBufferStarvation 1.3.6.1.4.1.3607.6.10.30.0.5670
GFP Fibre Channel Distance Extension Buffer Starvation
NOTIFICATION-TYPE    

gfpFibreChannelDistanceExtensionCreditStarvation 1.3.6.1.4.1.3607.6.10.30.0.5680
Fibre Channel Distance Extension Credit Starvation
NOTIFICATION-TYPE    

automaticWdmAnsFinished 1.3.6.1.4.1.3607.6.10.30.0.5690
Automatic WDM ANS Finished
NOTIFICATION-TYPE    

gfpClientSignalFailDetected 1.3.6.1.4.1.3607.6.10.30.0.5700
GFP Client Signal Fail Detected
NOTIFICATION-TYPE    

gfpLossOfFrameDelineation 1.3.6.1.4.1.3607.6.10.30.0.5710
GFP Loss of Frame Delineation
NOTIFICATION-TYPE    

gfpExtensionHeaderMismatch 1.3.6.1.4.1.3607.6.10.30.0.5730
GFP Extension Header Mismatch
NOTIFICATION-TYPE    

incomingOverheadSignalAbsent 1.3.6.1.4.1.3607.6.10.30.0.5740
Incoming Overhead Signal Absent
NOTIFICATION-TYPE    

opticalSafetyRemoteInterlockOn 1.3.6.1.4.1.3607.6.10.30.0.5750
Optical Safety Remote Interlock On
NOTIFICATION-TYPE    

automaticPowerControlCorrectionSkipped 1.3.6.1.4.1.3607.6.10.30.0.5770
Automatic Power Control Correction Skipped
NOTIFICATION-TYPE    

apcCannotSetValueDueToRangeLimits 1.3.6.1.4.1.3607.6.10.30.0.5780
APC cannot set value due to range limits
NOTIFICATION-TYPE    

lcasVcgMemberTxSideInAddState 1.3.6.1.4.1.3607.6.10.30.0.5790
LCAS VCG Member Tx Side In ADD State
NOTIFICATION-TYPE    

farEndManualSwitchBackToWorkingSpan 1.3.6.1.4.1.3607.6.10.30.0.5800
Far End Manual Switch Back to Working - Span
NOTIFICATION-TYPE    

farEndForcedSwitchBackToWorkingSpan 1.3.6.1.4.1.3607.6.10.30.0.5810
Far End Forced Switch Back to Working - Span
NOTIFICATION-TYPE    

universalTransponderModuleHardwareFailure 1.3.6.1.4.1.3607.6.10.30.0.5820
Universal Transponder Module Hardware Failure
NOTIFICATION-TYPE    

universalTransponderModuleCommunicationFailure 1.3.6.1.4.1.3607.6.10.30.0.5830
Universal Transponder Module Communication Failure
NOTIFICATION-TYPE    

pluginModuleRangeSettingsMismatch 1.3.6.1.4.1.3607.6.10.30.0.5840
Plug-in Module Range Settings Mismatch
NOTIFICATION-TYPE    

lcasVcgMemberTxSideInDnuState 1.3.6.1.4.1.3607.6.10.30.0.5850
LCAS VCG Member Tx Side In DNU State
NOTIFICATION-TYPE    

lcasControlWordCrcCheckFailure 1.3.6.1.4.1.3607.6.10.30.0.5860
LCAS Control Word CRC Check Failure
NOTIFICATION-TYPE    

lcasVcgMemberRxSideInFailState 1.3.6.1.4.1.3607.6.10.30.0.5870
LCAS VCG Member Rx Side In FAIL State
NOTIFICATION-TYPE    

signalLossOnDataInterface 1.3.6.1.4.1.3607.6.10.30.0.5880
Signal Loss on Data Interface
NOTIFICATION-TYPE    

synchronizationLossOnDataInterface 1.3.6.1.4.1.3607.6.10.30.0.5890
Synchronization Loss on Data Interface
NOTIFICATION-TYPE    

portFAIL 1.3.6.1.4.1.3607.6.10.30.0.5900
PORT FAIL
NOTIFICATION-TYPE    

unreachablePortTargetPower 1.3.6.1.4.1.3607.6.10.30.0.5910
Unreachable port target power
NOTIFICATION-TYPE    

portAddPowerDegradeLow 1.3.6.1.4.1.3607.6.10.30.0.5920
Port Add Power Degrade Low
NOTIFICATION-TYPE    

portAddPowerDegradeHigh 1.3.6.1.4.1.3607.6.10.30.0.5930
Port Add Power Degrade High
NOTIFICATION-TYPE    

portAddPowerFailLow 1.3.6.1.4.1.3607.6.10.30.0.5940
Port Add Power Fail Low
NOTIFICATION-TYPE    

portAddPowerFailHigh 1.3.6.1.4.1.3607.6.10.30.0.5950
Port Add Power Fail High
NOTIFICATION-TYPE    

automaticPowerControlTerminatedOnManualRequest 1.3.6.1.4.1.3607.6.10.30.0.6000
Automatic Power Control Terminated on Manual request
NOTIFICATION-TYPE    

oduk1AlarmIndicationSignal 1.3.6.1.4.1.3607.6.10.30.0.6010
ODUk-1: Alarm Indication Signal
NOTIFICATION-TYPE    

oduk2AlarmIndicationSignal 1.3.6.1.4.1.3607.6.10.30.0.6020
ODUk-2: Alarm Indication Signal
NOTIFICATION-TYPE    

oduk3AlarmIndicationSignal 1.3.6.1.4.1.3607.6.10.30.0.6030
ODUk-3: Alarm Indication Signal
NOTIFICATION-TYPE    

oduk4AlarmIndicationSignal 1.3.6.1.4.1.3607.6.10.30.0.6040
ODUk-4: Alarm Indication Signal
NOTIFICATION-TYPE    

temperatureReadingMismatchBetweenSCCards 1.3.6.1.4.1.3607.6.10.30.0.6050
Temperature Reading Mismatch Between SC Cards
NOTIFICATION-TYPE    

voltageReadingMismatchBetweenSCCards 1.3.6.1.4.1.3607.6.10.30.0.6060
Voltage Reading Mismatch Between SC Cards
NOTIFICATION-TYPE    

alarmsSuppressedonOutOfGroupVcatMember 1.3.6.1.4.1.3607.6.10.30.0.6070
Alarms Suppressed on Out-Of-Group VCAT Member
NOTIFICATION-TYPE    

blsrSoftwareVersionMismatch 1.3.6.1.4.1.3607.6.10.30.0.6080
BLSR Software Version Mismatch
NOTIFICATION-TYPE    

optimized1Plus1ApsPrimaryFacility 1.3.6.1.4.1.3607.6.10.30.0.6090
Optimized 1+1 APS Primary Facility
NOTIFICATION-TYPE    

optimized1Plus1ApsPrimarySectionMismatch 1.3.6.1.4.1.3607.6.10.30.0.6100
Optimized 1+1 APS Primary Section Mismatch
NOTIFICATION-TYPE    

optimized1Plus1ApsInvalidPrimarySection 1.3.6.1.4.1.3607.6.10.30.0.6110
Optimized 1+1 APS Invalid Primary Section
NOTIFICATION-TYPE    

compositeClockHighLineVoltage 1.3.6.1.4.1.3607.6.10.30.0.6120
Composite Clock High Line Voltage
NOTIFICATION-TYPE    

berThresholdExceededForSignalDegradeVt 1.3.6.1.4.1.3607.6.10.30.0.6130
BER Threshold Exceeded For Signal Degrade - VT
NOTIFICATION-TYPE    

berThresholdExceededForSignalFailureVt 1.3.6.1.4.1.3607.6.10.30.0.6140
BER Threshold Exceeded For Signal Failure - VT
NOTIFICATION-TYPE    

spanLengthOutOfRange 1.3.6.1.4.1.3607.6.10.30.0.6150
Span Length Out of Range
NOTIFICATION-TYPE    

idleSignalCondition 1.3.6.1.4.1.3607.6.10.30.0.6170
Idle Signal Condition
NOTIFICATION-TYPE    

idleSignalConditionInTx 1.3.6.1.4.1.3607.6.10.30.0.6180
Idle Signal Condition in TX
NOTIFICATION-TYPE    

vtPathTraceIdentifierMismatch 1.3.6.1.4.1.3607.6.10.30.0.6190
VT Path Trace Identifier Mismatch
NOTIFICATION-TYPE    

lossOfFrameInTX 1.3.6.1.4.1.3607.6.10.30.0.6200
Loss of Frame in TX
NOTIFICATION-TYPE    

provisioningMismatch 1.3.6.1.4.1.3607.6.10.30.0.6210
Provisioning Mismatch
NOTIFICATION-TYPE    

sectionTraceIdentifierMismatch 1.3.6.1.4.1.3607.6.10.30.0.6220
Section Trace Identifier Mismatch
NOTIFICATION-TYPE    

regeneratorSectionTraceIdentifierMismatch 1.3.6.1.4.1.3607.6.10.30.0.6230
Regenerator Section Trace Identifier Mismatch
NOTIFICATION-TYPE    

switchingMatrixModuleFailureWorking 1.3.6.1.4.1.3607.6.10.30.0.6240
Switching Matrix Module Failure - Working
NOTIFICATION-TYPE    

switchingMatrixModuleFailureProtect 1.3.6.1.4.1.3607.6.10.30.0.6250
Switching Matrix Module Failure - Protect
NOTIFICATION-TYPE    

slotCommunicationDisabled 1.3.6.1.4.1.3607.6.10.30.0.6260
Slot Communication Disabled
NOTIFICATION-TYPE    

sessionTimeLimitExpired 1.3.6.1.4.1.3607.6.10.30.0.6270
Session Time Limit Expired
NOTIFICATION-TYPE    

userPasswordChangeRequired 1.3.6.1.4.1.3607.6.10.30.0.6280
User Password Change Required
NOTIFICATION-TYPE    

isisAdjacencyFailure 1.3.6.1.4.1.3607.6.10.30.0.6290
ISIS Adjacency Failure
NOTIFICATION-TYPE    

msspSoftwareVersionMismatch 1.3.6.1.4.1.3607.6.10.30.0.6300
MSSP Software Version Mismatch
NOTIFICATION-TYPE    

remoteAuthenticationFailSeeAuditLog 1.3.6.1.4.1.3607.6.10.30.0.6310
Remote Authentication Fail - See Audit Log
NOTIFICATION-TYPE    

ringIsSquelchingStsTraffic 1.3.6.1.4.1.3607.6.10.30.0.6330
Ring Is Squelching STS Traffic
NOTIFICATION-TYPE    

ringIsSquelchingVtTraffic 1.3.6.1.4.1.3607.6.10.30.0.6340
Ring Is Squelching VT Traffic
NOTIFICATION-TYPE    

archiveOfAuditLogFailed 1.3.6.1.4.1.3607.6.10.30.0.6350
Archival of Audit Log Failed
NOTIFICATION-TYPE    

rprWrapped 1.3.6.1.4.1.3607.6.10.30.0.6360
RPR Wrapped
NOTIFICATION-TYPE    

shelfCommunicationFailure 1.3.6.1.4.1.3607.6.10.30.0.6370
Shelf Communication Failure
NOTIFICATION-TYPE    

duplicatedShelfIdentifier 1.3.6.1.4.1.3607.6.10.30.0.6380
Duplicated Shelf Identifier
NOTIFICATION-TYPE    

softwareMismatch 1.3.6.1.4.1.3607.6.10.30.0.6390
Software Mismatch
NOTIFICATION-TYPE    

lmpFailure 1.3.6.1.4.1.3607.6.10.30.0.6400
LMP Failure
NOTIFICATION-TYPE    

opticalTerminationIncomplete 1.3.6.1.4.1.3607.6.10.30.0.6410
Optical Termination Incomplete
NOTIFICATION-TYPE    

forwardDefectIndication 1.3.6.1.4.1.3607.6.10.30.0.6420
Forward Defect Indication
NOTIFICATION-TYPE    

payloadMissingIndication 1.3.6.1.4.1.3607.6.10.30.0.6430
Payload Missing Indication
NOTIFICATION-TYPE    

spanMeasurementCannotBePerformed 1.3.6.1.4.1.3607.6.10.30.0.6440
Span loss not checked
NOTIFICATION-TYPE    

ringIsSquelchingHighOrderTraffic 1.3.6.1.4.1.3607.6.10.30.0.6450
Ring Is Squelching High Order Traffic
NOTIFICATION-TYPE    

ringIsSquelchingLowOrderTraffic 1.3.6.1.4.1.3607.6.10.30.0.6460
Ring Is Squelching Low Order Traffic
NOTIFICATION-TYPE    

badPacketCountExceedsThreshold 1.3.6.1.4.1.3607.6.10.30.0.6470
Bad Packet Count Exceeds Threshold
NOTIFICATION-TYPE    

linkLayerKeepAliveFailure 1.3.6.1.4.1.3607.6.10.30.0.6480
Link Layer Keep-Alive Failure
NOTIFICATION-TYPE    

autonegotiationRemoteFailureIndication 1.3.6.1.4.1.3607.6.10.30.0.6490
Auto-Negotiation Remote Failure Indication
NOTIFICATION-TYPE    

trailSignalFail 1.3.6.1.4.1.3607.6.10.30.0.6500
Trail Signal Fail
NOTIFICATION-TYPE    

ds1LoopbackCommandSentToFarEnd 1.3.6.1.4.1.3607.6.10.30.0.6510
DS1 Loopback Command Sent To Far End
NOTIFICATION-TYPE    

multiplexSectionSignalDegraded 1.3.6.1.4.1.3607.6.10.30.0.6520
Multiplex Section - Signal Degraded
NOTIFICATION-TYPE    

multiplexSectionExcessiveErrors 1.3.6.1.4.1.3607.6.10.30.0.6530
Multiplex Section - Excessive Errors
NOTIFICATION-TYPE    

highOrderPathSignalDegraded 1.3.6.1.4.1.3607.6.10.30.0.6540
High Order Path - Signal Degraded
NOTIFICATION-TYPE    

highOrderPathExcessiveErrors 1.3.6.1.4.1.3607.6.10.30.0.6550
High Order Path - Excessive Errors
NOTIFICATION-TYPE    

lowOrderPathSignalDegraded 1.3.6.1.4.1.3607.6.10.30.0.6560
Low Order Path - Signal Degraded
NOTIFICATION-TYPE    

lowOrderPathExcessiveErrors 1.3.6.1.4.1.3607.6.10.30.0.6570
Low Order Path - Excessive Errors
NOTIFICATION-TYPE    

regeneratorSectionDccTerminationFailure 1.3.6.1.4.1.3607.6.10.30.0.6580
Regenerator Section - DCC Termination Failure
NOTIFICATION-TYPE    

networkMemoryPoolLow 1.3.6.1.4.1.3607.6.10.30.0.6590
Network Memory Pool Low
NOTIFICATION-TYPE    

ospfRoutingTableOverflow 1.3.6.1.4.1.3607.6.10.30.0.6600
OSPF Routing Table Overflow
NOTIFICATION-TYPE    

autoLaserShutdownDisabled 1.3.6.1.4.1.3607.6.10.30.0.6610
Auto Laser Shutdown Disabled
NOTIFICATION-TYPE    

rprProtectionIsActive 1.3.6.1.4.1.3607.6.10.30.0.6630
RPR Protection Is Active
NOTIFICATION-TYPE    

maxRPRStationNumberExceeded 1.3.6.1.4.1.3607.6.10.30.0.6640
Max RPR Station Number Exceeded
NOTIFICATION-TYPE    

rprProtectionConfigurationMismatched 1.3.6.1.4.1.3607.6.10.30.0.6650
RPR Protection Configuration Mismatched
NOTIFICATION-TYPE    

reservedBandwidthLinkRateExceededOnRinglet0 1.3.6.1.4.1.3607.6.10.30.0.6660
Reserved Bandwidth Link Rate Exceeded On Ringlet0
NOTIFICATION-TYPE    

reservedBandwidthLinkRateExceededOnRinglet1 1.3.6.1.4.1.3607.6.10.30.0.6670
Reserved Bandwidth Link Rate Exceeded On Ringlet1
NOTIFICATION-TYPE    

rprInterfaceInPassThroughMode 1.3.6.1.4.1.3607.6.10.30.0.6680
RPR Interface In Pass Through Mode
NOTIFICATION-TYPE    

rprPeerNodeIsMissing 1.3.6.1.4.1.3607.6.10.30.0.6690
RPR Peer Node is Missing
NOTIFICATION-TYPE    

rprRiFailure 1.3.6.1.4.1.3607.6.10.30.0.6700
RPR RI Failure
NOTIFICATION-TYPE    

rprSignalFailure 1.3.6.1.4.1.3607.6.10.30.0.6710
RPR Signal Failure
NOTIFICATION-TYPE    

rprSignalDegrade 1.3.6.1.4.1.3607.6.10.30.0.6720
RPR Signal Degrade
NOTIFICATION-TYPE    

interlinkFailure 1.3.6.1.4.1.3607.6.10.30.0.6730
ADM Peer Cards Interlink Failure
NOTIFICATION-TYPE    

apcWrongGain 1.3.6.1.4.1.3607.6.10.30.0.6740
APC Wrong Gain Set Point
NOTIFICATION-TYPE    

rprSpanMismatch 1.3.6.1.4.1.3607.6.10.30.0.6750
RPR Span Mismatch
NOTIFICATION-TYPE    

efmRemoteFaultIndicationCriticalEvent 1.3.6.1.4.1.3607.6.10.30.0.6760
EFM Remote Fault Inidication- Critical Event
NOTIFICATION-TYPE    

efmRemoteFaultIndicationDyingGasp 1.3.6.1.4.1.3607.6.10.30.0.6770
EFM Remote Fault Inidication- Dying Gasp
NOTIFICATION-TYPE    

efmRemoteFaultIndicationLinkFault 1.3.6.1.4.1.3607.6.10.30.0.6780
EFM Remote Fault Inidication- Link Fault
NOTIFICATION-TYPE    

efmLinkMonitoringErroredSymbolPeriodEvent 1.3.6.1.4.1.3607.6.10.30.0.6790
EFM Link Monitoring- Errored Symbol Period Event
NOTIFICATION-TYPE    

efmLinkMonitoringErroredFrameEvent 1.3.6.1.4.1.3607.6.10.30.0.6800
EFM Link Monitoring- Errored Frame Event
NOTIFICATION-TYPE    

efmLinkMonitoringErroredFramePeriodEvent 1.3.6.1.4.1.3607.6.10.30.0.6810
EFM Link Monitoring- Errored Frame Period Event
NOTIFICATION-TYPE    

efmLinkMonitoringErroredFrameSecondsSummary 1.3.6.1.4.1.3607.6.10.30.0.6820
EFM Link Monitoring- Errored Frame Seconds Summary
NOTIFICATION-TYPE    

efmRemoteLoopbackRequestFailed 1.3.6.1.4.1.3607.6.10.30.0.6830
EFM Remote Loopback Request Failed
NOTIFICATION-TYPE    

fastAutomaticProtectionSwitching 1.3.6.1.4.1.3607.6.10.30.0.6840
Fast Automatic Protection Switching
NOTIFICATION-TYPE    

fastAutomaticProtectionSwitchingConfigMismatch 1.3.6.1.4.1.3607.6.10.30.0.6850
Fast Automatic Protection Switching Config Mismatch
NOTIFICATION-TYPE    

lcasSinkGroupError 1.3.6.1.4.1.3607.6.10.30.0.6860
LCAS Sink Group Error
NOTIFICATION-TYPE    

lcasVcgMemberRxSideInDnuState 1.3.6.1.4.1.3607.6.10.30.0.6870
LCAS VCG Member Rx Side In DNU State
NOTIFICATION-TYPE    

fcDistanceExtFuncNotEstablished 1.3.6.1.4.1.3607.6.10.30.0.6880
Fibre Channel Distance Extension Function Not Established
NOTIFICATION-TYPE    

nonCiscoPPMInserted 1.3.6.1.4.1.3607.6.10.30.0.6890
Non Cisco PPM Inserted
NOTIFICATION-TYPE    

unqualifiedPPMInserted 1.3.6.1.4.1.3607.6.10.30.0.6900
Unqualified PPM Inserted
NOTIFICATION-TYPE    

ftaMismatch 1.3.6.1.4.1.3607.6.10.30.0.6910
FanTray Mismatch
NOTIFICATION-TYPE    

cardPortsUnableToProvideProtection 1.3.6.1.4.1.3607.6.10.30.0.6920
Card/Ports Unable To Provide Protection
NOTIFICATION-TYPE    

lmpSignalDegrade 1.3.6.1.4.1.3607.6.10.30.0.6930
LMP Signal Degrade
NOTIFICATION-TYPE    

lmpSignalFailure 1.3.6.1.4.1.3607.6.10.30.0.6940
LMP Signal Failure
NOTIFICATION-TYPE    


frontPortLinkLoss 1.3.6.1.4.1.3607.6.10.30.0.6960
TCC Front Port Link Loss
NOTIFICATION-TYPE    

bertEnbl 1.3.6.1.4.1.3607.6.10.30.0.6970
BERT Enabled
NOTIFICATION-TYPE    

bertSyncFail 1.3.6.1.4.1.3607.6.10.30.0.6975
BERT Synchronization Status Failed
NOTIFICATION-TYPE    

workQueueFull 1.3.6.1.4.1.3607.6.10.30.0.6980
Work Queue Full
NOTIFICATION-TYPE    

equipmentPowerFailureAtConnectorA 1.3.6.1.4.1.3607.6.10.30.0.7000
Equipment power failure at connector A
NOTIFICATION-TYPE    

equipmentPowerFailureAtConnectorB 1.3.6.1.4.1.3607.6.10.30.0.7005
Equipment power failure at connector B
NOTIFICATION-TYPE    

equipmentPowerFailureAtReturnConnectorA 1.3.6.1.4.1.3607.6.10.30.0.7010
Equipment power failure at return connector A
NOTIFICATION-TYPE    

equipmentPowerFailureAtReturnConnectorB 1.3.6.1.4.1.3607.6.10.30.0.7015
Equipment power failure at return connector B
NOTIFICATION-TYPE    

bridgeAndRollHasOccurred 1.3.6.1.4.1.3607.6.10.30.0.7055
Bridge and Roll Has Occurred
NOTIFICATION-TYPE    

bridgeAndRollIsPendingAValidSignal 1.3.6.1.4.1.3607.6.10.30.0.7060
Bridge and Roll is Pending a Valid Signal
NOTIFICATION-TYPE    

clockBusFailureTscA 1.3.6.1.4.1.3607.6.10.30.0.7160
Clock Bus Failure - Shelf Controller A
NOTIFICATION-TYPE    

clockBusFailureTscB 1.3.6.1.4.1.3607.6.10.30.0.7165
Clock Bus Failure - Shelf Controller B
NOTIFICATION-TYPE    

ospfHelloFail 1.3.6.1.4.1.3607.6.10.30.0.7185
OSPF Hello Fail
NOTIFICATION-TYPE    

openIOSlots 1.3.6.1.4.1.3607.6.10.30.0.7200
Open IO Slots
NOTIFICATION-TYPE    

lossOfClockFromMateShelfController 1.3.6.1.4.1.3607.6.10.30.0.7210
Loss of Clock from Mate Shelf Controller
NOTIFICATION-TYPE    

virtualLanAlarmIndicationSignal 1.3.6.1.4.1.3607.6.10.30.0.7225
Virtual Lan AIS
NOTIFICATION-TYPE    

dcuLossFailure 1.3.6.1.4.1.3607.6.10.30.0.7230
DCU Loss Failure
NOTIFICATION-TYPE    

ochncMaintenance 1.3.6.1.4.1.3607.6.10.30.0.7235
OCHNC Maintenance
NOTIFICATION-TYPE    

ramanLaserShutdown 1.3.6.1.4.1.3607.6.10.30.0.7240
Raman Laser Shutdown
NOTIFICATION-TYPE    

losOfRamanSignal 1.3.6.1.4.1.3607.6.10.30.0.7245
Loss Of Raman Signal
NOTIFICATION-TYPE    

mcastMacTableFull 1.3.6.1.4.1.3607.6.10.30.0.7250
Multicast Mac Address Table Full
NOTIFICATION-TYPE    

multicastMacAddressAliasing 1.3.6.1.4.1.3607.6.10.30.0.7255
Multicast Mac Address Aliasing
NOTIFICATION-TYPE    

ramanPwrProtOn 1.3.6.1.4.1.3607.6.10.30.0.7260
Raman Power Protection On
NOTIFICATION-TYPE    

cppPeerNotResponding 1.3.6.1.4.1.3607.6.10.30.0.7265
CPP Peer Not Responding
NOTIFICATION-TYPE    

voaControlLoopDisableDueToExcessiveCounterPropagationLight 1.3.6.1.4.1.3607.6.10.30.0.7275
VOA Control Loop Disable Due To Excessive Counter-Propagation Light
NOTIFICATION-TYPE    

wizardIsRunning 1.3.6.1.4.1.3607.6.10.30.0.7280
Wizard Is Running
NOTIFICATION-TYPE    

ramanGainNotReached 1.3.6.1.4.1.3607.6.10.30.0.7285
Raman Span Not Tuned
NOTIFICATION-TYPE    

pprForwardDefectIndication 1.3.6.1.4.1.3607.6.10.30.0.7295
pprForwardDefectIndication
NOTIFICATION-TYPE    

pprBackwardDefectIndication 1.3.6.1.4.1.3607.6.10.30.0.7300
pprBackwardDefectIndication
NOTIFICATION-TYPE    

pprCoordinatedMaintenance 1.3.6.1.4.1.3607.6.10.30.0.7305
pprCoordinatedMaintenance
NOTIFICATION-TYPE    

pprTriggerThresholdBERExceeded 1.3.6.1.4.1.3607.6.10.30.0.7310
pprTriggerThresholdBERExceeded
NOTIFICATION-TYPE    

localFault 1.3.6.1.4.1.3607.6.10.30.0.7315
Local Fault
NOTIFICATION-TYPE    

remoteFault 1.3.6.1.4.1.3607.6.10.30.0.7320
Remote Fault
NOTIFICATION-TYPE    

efmRemoteLoopbackConfigured 1.3.6.1.4.1.3607.6.10.30.0.7325
EFM Port In Remote Loopback
NOTIFICATION-TYPE    

efmPeerMissing 1.3.6.1.4.1.3607.6.10.30.0.7330
EFM Link To Peer Missing
NOTIFICATION-TYPE    

eqptDegrade 1.3.6.1.4.1.3607.6.10.30.0.7335
Equipment Degrade
NOTIFICATION-TYPE    

excessiveBackPropagation 1.3.6.1.4.1.3607.6.10.30.0.7340
Excessive Back Propagation
NOTIFICATION-TYPE    

remoteMaintenanceEndPointIsDown 1.3.6.1.4.1.3607.6.10.30.0.7345
CFM Remote Maintenance End Point Is Down
NOTIFICATION-TYPE    

crossConnectedCFMService 1.3.6.1.4.1.3607.6.10.30.0.7350
Cross Connected CFM Service
NOTIFICATION-TYPE    

cfmLoop 1.3.6.1.4.1.3607.6.10.30.0.7355
CFM Loop
NOTIFICATION-TYPE    

cfmConfigurationError 1.3.6.1.4.1.3607.6.10.30.0.7360
CFM Configuration Error
NOTIFICATION-TYPE    

outOfChannelGroupBundle 1.3.6.1.4.1.3607.6.10.30.0.7365
Out Of Channel Group Bundle
NOTIFICATION-TYPE    

repNeighborAdjacencyFailure 1.3.6.1.4.1.3607.6.10.30.0.7370
REP Neighbor Adjacency Failure
NOTIFICATION-TYPE    

repLinkFlapping 1.3.6.1.4.1.3607.6.10.30.0.7375
REP Link Flapping
NOTIFICATION-TYPE    

faultInREPSegment 1.3.6.1.4.1.3607.6.10.30.0.7380
Fault In REP Segment
NOTIFICATION-TYPE    

primaryREPEdgePortElected 1.3.6.1.4.1.3607.6.10.30.0.7385
Primary REP Edge Port Elected
NOTIFICATION-TYPE    

secondaryREPEdgePortElected 1.3.6.1.4.1.3607.6.10.30.0.7390
Secondary REP Edge Port Elected
NOTIFICATION-TYPE    

stcnREPGenerated 1.3.6.1.4.1.3607.6.10.30.0.7395
STCN REP Generated
NOTIFICATION-TYPE    

vlbREPActivated 1.3.6.1.4.1.3607.6.10.30.0.7400
VLB REP Activated
NOTIFICATION-TYPE    

vlbREPTriggerSoakingDelayActive 1.3.6.1.4.1.3607.6.10.30.0.7405
VLB REP Trigger Soaking Delay Active
NOTIFICATION-TYPE    

wanSyncloss 1.3.6.1.4.1.3607.6.10.30.0.7410
Ethernet Syncloss On WAN Port
NOTIFICATION-TYPE    

laserShutdownDueToWavelengthDrift 1.3.6.1.4.1.3607.6.10.30.0.7415
laser Shutdown Due To Wavelength Drift
NOTIFICATION-TYPE    

manualLaserRestart 1.3.6.1.4.1.3607.6.10.30.0.7420
manual Laser Restart
NOTIFICATION-TYPE    

laserShutdownDueToNonCiscoPPMInserted 1.3.6.1.4.1.3607.6.10.30.0.7425
laserShutdownDueToNonCiscoPPMInserted
NOTIFICATION-TYPE    

ethernetOSCTerminationFailure 1.3.6.1.4.1.3607.6.10.30.0.7430
Ethernet OSC Termination Failure
NOTIFICATION-TYPE    

softwareSignatureVerificationFailed 1.3.6.1.4.1.3607.6.10.30.0.7445
software Signature Verification Failed
NOTIFICATION-TYPE    

protectVolumeSoftwareSignatureVerificationFailed 1.3.6.1.4.1.3607.6.10.30.0.7450
Protect Volume Software Signature Verification
NOTIFICATION-TYPE    

activeVolumeSoftwareSignatureVerificationFailed 1.3.6.1.4.1.3607.6.10.30.0.7455
Active Software Signature Verification Failed
NOTIFICATION-TYPE    

peerPortClientSignalFailDetected 1.3.6.1.4.1.3607.6.10.30.0.7460
Peer Port Client Signal Fail Detected
NOTIFICATION-TYPE    

channelShutdownDueToWavelengthDrift 1.3.6.1.4.1.3607.6.10.30.0.7465
Channel Shutdown Due to Wavelength Drift
NOTIFICATION-TYPE    

usbWriteFailure 1.3.6.1.4.1.3607.6.10.30.0.7475
USB Write Failure
NOTIFICATION-TYPE    

usbSyncInProgress 1.3.6.1.4.1.3607.6.10.30.0.7480
USB Sync in Progress
NOTIFICATION-TYPE    

autoSensingUnableToDetectValidPayload 1.3.6.1.4.1.3607.6.10.30.0.7485
Auto-Sensing Unable To Detect Valid Payload
NOTIFICATION-TYPE    

payloadAutoSensingInProgress 1.3.6.1.4.1.3607.6.10.30.0.7490
Payload Auto-Sensing In Progress
NOTIFICATION-TYPE    

gfpClientSignalFailDetectedDueToSigloss 1.3.6.1.4.1.3607.6.10.30.0.7495
GFP Client Signal Fail Detected Due To Sigloss
NOTIFICATION-TYPE    

gfpClientSignalFailDetectedDueToSyncloss 1.3.6.1.4.1.3607.6.10.30.0.7500
GFP Client Signal Fail Detected Due To Syncloss
NOTIFICATION-TYPE    

pmdDegrade 1.3.6.1.4.1.3607.6.10.30.0.7510
PMD Degrade
NOTIFICATION-TYPE    

standbyTccNEClockIsInternalClock 1.3.6.1.4.1.3607.6.10.30.0.7515
Standby Tcc NE Clock Is Internal Clock
NOTIFICATION-TYPE    

chromaticDispersionValue 1.3.6.1.4.1.3607.6.10.30.0.7520
chromatic Dispersion Value
NOTIFICATION-TYPE    

packetTransportServiceFailed 1.3.6.1.4.1.3607.6.10.30.0.7525
Packet Transport Service Failed
NOTIFICATION-TYPE    

satellitePanelDiscoveryFailure 1.3.6.1.4.1.3607.6.10.30.0.7530
Satellite Panel Discovery Failure
NOTIFICATION-TYPE    

satellitePanelActiveLinkFailure 1.3.6.1.4.1.3607.6.10.30.0.7535
Satellite Panel Active Link Failure
NOTIFICATION-TYPE    

satellitePanelCommunicationFailure 1.3.6.1.4.1.3607.6.10.30.0.7540
Satellite Panel Communication Failure
NOTIFICATION-TYPE    

satellitePanelImproperConfiguration 1.3.6.1.4.1.3607.6.10.30.0.7545
Satellite Panel Improper Configuration
NOTIFICATION-TYPE    

satellitePanelFanMismatchOfEquipmentAndAttributes 1.3.6.1.4.1.3607.6.10.30.0.7550
Satellite Panel Fan Mismatch Of Equipment And Attributes
NOTIFICATION-TYPE    

satellitePanelFanFailure 1.3.6.1.4.1.3607.6.10.30.0.7555
Satellite Panel Fan Failure
NOTIFICATION-TYPE    

satellitePanelPartialFanFailure 1.3.6.1.4.1.3607.6.10.30.0.7560
Satellite Panel Partial Fan Failure
NOTIFICATION-TYPE    

satellitePanelFANManufacturingDataMemoryEEPROMFailure 1.3.6.1.4.1.3607.6.10.30.0.7565
Satellite Panel FAN Manufacturing Data Memory (EEPROM) Failure
NOTIFICATION-TYPE    

satellitePanelFANUnitIsMissing 1.3.6.1.4.1.3607.6.10.30.0.7570
Satellite Panel FAN Unit Is Missing
NOTIFICATION-TYPE    

satellitePanelIndustrialHighTemperature 1.3.6.1.4.1.3607.6.10.30.0.7575
Satellite Panel Industrial High Temperature
NOTIFICATION-TYPE    

satellitePanelHighTemperature 1.3.6.1.4.1.3607.6.10.30.0.7580
Satellite Panel High Temperature
NOTIFICATION-TYPE    

satellitePanelBatteryFailureA 1.3.6.1.4.1.3607.6.10.30.0.7585
Satellite Panel Battery Failure A
NOTIFICATION-TYPE    

plannedSwitchOver 1.3.6.1.4.1.3607.6.10.30.0.7590
Planned Switch Over
NOTIFICATION-TYPE    

protectionCardConfigurationMismatch 1.3.6.1.4.1.3607.6.10.30.0.7595
protection CardConfiguration Mismatch
NOTIFICATION-TYPE    

routerProcessorSwitchOver 1.3.6.1.4.1.3607.6.10.30.0.7600
Router Processor Switch Over
NOTIFICATION-TYPE    

runningLowOnResources 1.3.6.1.4.1.3607.6.10.30.0.7605
Running Low On Resources
NOTIFICATION-TYPE    

noMoreResourcesAreAvailable 1.3.6.1.4.1.3607.6.10.30.0.7610
No More Resources Are Available
NOTIFICATION-TYPE    

esmcFailure 1.3.6.1.4.1.3607.6.10.30.0.7615
ESMC Failure
NOTIFICATION-TYPE    

licenseWillExpireWithin24Hours 1.3.6.1.4.1.3607.6.10.30.0.7620
License Will Expire Within 24 Hours
NOTIFICATION-TYPE    

licenseWillExpireAnytimeAfter1DayButBefore14Days 1.3.6.1.4.1.3607.6.10.30.0.7625
license Will Expire Anytime After 1Day But Before 14Days
NOTIFICATION-TYPE    

licenseIsExpired 1.3.6.1.4.1.3607.6.10.30.0.7630
license Is Expired
NOTIFICATION-TYPE    

licenseCountViolation 1.3.6.1.4.1.3607.6.10.30.0.7635
license Count Violation
NOTIFICATION-TYPE    

temporaryLicenseIsInUse 1.3.6.1.4.1.3607.6.10.30.0.7640
Temporary License Is In Use
NOTIFICATION-TYPE    

evaluationLicenseIsInUse 1.3.6.1.4.1.3607.6.10.30.0.7645
Evaluation License Is In Use
NOTIFICATION-TYPE    

licenseIsMissing 1.3.6.1.4.1.3607.6.10.30.0.7650
License Is Missing
NOTIFICATION-TYPE    

pseudowireDown 1.3.6.1.4.1.3607.6.10.30.0.7655
Pseudowire Down
NOTIFICATION-TYPE    

workingPseudowireControlPlaneDown 1.3.6.1.4.1.3607.6.10.30.0.7660
Working Pseudowire Control Plane Down
NOTIFICATION-TYPE    

protectPseudowireControlPlaneDown 1.3.6.1.4.1.3607.6.10.30.0.7665
Protect Pseudowire Control Plane Down
NOTIFICATION-TYPE    

workingPseudowireConnectivityCheckDown 1.3.6.1.4.1.3607.6.10.30.0.7670
Working Pseudowire Connectivity Check Down
NOTIFICATION-TYPE    

protectPseudowireConnectivityCheckDown 1.3.6.1.4.1.3607.6.10.30.0.7675
Protect Pseudowire Connectivity Check Down
NOTIFICATION-TYPE    

pseudowireTrafficSwitchedToProtection 1.3.6.1.4.1.3607.6.10.30.0.7680
Pseudowire Traffic Switched To Pretection
NOTIFICATION-TYPE    

workingPseudowireLocalAcTxPortFault 1.3.6.1.4.1.3607.6.10.30.0.7685
Working Pseudowire Local AcTx Port Fault
NOTIFICATION-TYPE    

protectPseudowireLocalAcTxPortFault 1.3.6.1.4.1.3607.6.10.30.0.7690
Protect Pseudowire Local AcTx Port Fault
NOTIFICATION-TYPE    

workingPseudowireLocalAcRxPortFault 1.3.6.1.4.1.3607.6.10.30.0.7695
Working Pseudowire Local AcRx Port Fault
NOTIFICATION-TYPE    

protectPseudowireLocalAcRxPortFault 1.3.6.1.4.1.3607.6.10.30.0.7700
Protect Pseudowire Local AcRx Port Fault
NOTIFICATION-TYPE    

workingPseudowireRemoteAcTxPortFault 1.3.6.1.4.1.3607.6.10.30.0.7705
Working Pseudowire Remote AcTx Port Fault
NOTIFICATION-TYPE    

protectPseudowireRemoteAcTxPortFault 1.3.6.1.4.1.3607.6.10.30.0.7710
Protect Pseudowire Remote AcTx Port Fault
NOTIFICATION-TYPE    

workingPseudowireRemoteAcRxPortFault 1.3.6.1.4.1.3607.6.10.30.0.7715
working Pseudowire Remote AcRx Port Fault
NOTIFICATION-TYPE    

protectPseudowireRemoteAcRxPortFault 1.3.6.1.4.1.3607.6.10.30.0.7720
Protect Pseudowire Remote AcRx Port Fault
NOTIFICATION-TYPE    

slaThresholdCrossAlert 1.3.6.1.4.1.3607.6.10.30.0.7725
SLA Threshold Cross Alert
NOTIFICATION-TYPE    

protectLocalPseudowireNotForwarding 1.3.6.1.4.1.3607.6.10.30.0.7730
Protect Local Pseudowire Not Forwarding
NOTIFICATION-TYPE    

workingPseudowireNotForwarding 1.3.6.1.4.1.3607.6.10.30.0.7735
Working Remote Pseudowire Not Forwarding
NOTIFICATION-TYPE    

protectPseudowireNotForwarding 1.3.6.1.4.1.3607.6.10.30.0.7740
Protect Remote Pseudowire Not Forwarding
NOTIFICATION-TYPE    

tpTunnelDown 1.3.6.1.4.1.3607.6.10.30.0.7745
Tp Tunnel Down
NOTIFICATION-TYPE    

workingLabelSwitchedPathDown 1.3.6.1.4.1.3607.6.10.30.0.7750
Working Label Switched Path Down
NOTIFICATION-TYPE    

protectLabelSwitchedPathDown 1.3.6.1.4.1.3607.6.10.30.0.7755
Protect Label Switched Path Down
NOTIFICATION-TYPE    

workingLabelSwitchedPathAlarmIndicationSignal 1.3.6.1.4.1.3607.6.10.30.0.7760
Working Label Switched Path Alarm Indication Signal
NOTIFICATION-TYPE    

protectLabelSwitchedPathAlarmIndicationSignal 1.3.6.1.4.1.3607.6.10.30.0.7765
Protect Label Switched Path Alarm Indication Signal
NOTIFICATION-TYPE    

workingLabelSwitchedPathRemoteDefectIndication 1.3.6.1.4.1.3607.6.10.30.0.7770
Working Label Switched Path Remote Defect Indication
NOTIFICATION-TYPE    

protectLabelSwitchedPathRemoteDefectIndication 1.3.6.1.4.1.3607.6.10.30.0.7775
Protect Label Switched Path Remote Defect Indication
NOTIFICATION-TYPE    

bidirectionalForwardDetectionDown 1.3.6.1.4.1.3607.6.10.30.0.7780
Bidirectional Forward Detection Down
NOTIFICATION-TYPE    

tpTrafficSwitchedFromWorkingToProtection 1.3.6.1.4.1.3607.6.10.30.0.7785
Tp Traffic Switched From Working To Protection
NOTIFICATION-TYPE    

workingTpLockout 1.3.6.1.4.1.3607.6.10.30.0.7790
working Tp Lockout
NOTIFICATION-TYPE    

protectTpLockout 1.3.6.1.4.1.3607.6.10.30.0.7795
protect Tp Lockout
NOTIFICATION-TYPE    

ethernetFlowPointFailed 1.3.6.1.4.1.3607.6.10.30.0.7800
Ethernet Flow Point Failed
NOTIFICATION-TYPE    

teTunnelDown 1.3.6.1.4.1.3607.6.10.30.0.7805
TE Tunnel Down
NOTIFICATION-TYPE    

macSystemLimitReached 1.3.6.1.4.1.3607.6.10.30.0.7810
MAC System Limit Reached
NOTIFICATION-TYPE    

macBridgeDomainLimitReached 1.3.6.1.4.1.3607.6.10.30.0.7815
MAC Bridge Domain Limit Reached
NOTIFICATION-TYPE    

autoSensingDisabled 1.3.6.1.4.1.3607.6.10.30.0.7820
Auto Sense Disabled
NOTIFICATION-TYPE    

smBackwardIncomingAlignmentError 1.3.6.1.4.1.3607.6.10.30.0.7825
SM Backward Incoming Alignment Error
NOTIFICATION-TYPE    

resourceAllocationFailed 1.3.6.1.4.1.3607.6.10.30.0.7830
Resource Allocation Failed
NOTIFICATION-TYPE    

lossOfDFBSignal 1.3.6.1.4.1.3607.6.10.30.0.7835
loss Of DFB Signal
NOTIFICATION-TYPE    

workingLabelSwitchedPathLinkDownIndication 1.3.6.1.4.1.3607.6.10.30.0.7840
Working Label Switched Path Link Down Indication
NOTIFICATION-TYPE    

protectLabelSwitchedPathLinkDownIndication 1.3.6.1.4.1.3607.6.10.30.0.7845
Protect Label Switched Path Link Down Indication
NOTIFICATION-TYPE    

workingLabelSwitchedPathLockReport 1.3.6.1.4.1.3607.6.10.30.0.7850
Working Label Switched Path Lock Report
NOTIFICATION-TYPE    

protectLabelSwitchedPathLockReport 1.3.6.1.4.1.3607.6.10.30.0.7855
Protect Label Switched Path Lock Report
NOTIFICATION-TYPE    

satellitePanelBatteryFailureB 1.3.6.1.4.1.3607.6.10.30.0.7860
satellite Panel Battery FailureB
NOTIFICATION-TYPE    

highBitErrorRate 1.3.6.1.4.1.3607.6.10.30.0.7865
High Bit Error Rate
NOTIFICATION-TYPE    

backPanelFacilityLoopback 1.3.6.1.4.1.3607.6.10.30.0.7870
Back Panel Facility Loopback
NOTIFICATION-TYPE    

backPanelTerminalLoopback 1.3.6.1.4.1.3607.6.10.30.0.7875
Back Panel Terminal Loopback
NOTIFICATION-TYPE    

trunkPayloadTypeMismatch 1.3.6.1.4.1.3607.6.10.30.0.7880
Payload Mismatch
NOTIFICATION-TYPE    

invalidMuxponderConfiguration 1.3.6.1.4.1.3607.6.10.30.0.7885
Invalid Muxponder Configuration
NOTIFICATION-TYPE    

coolingProfileMismatch 1.3.6.1.4.1.3607.6.10.30.0.7890
Cooling Profile Mismatch
NOTIFICATION-TYPE    

trunkOduAlarmIndicationSignal 1.3.6.1.4.1.3607.6.10.30.0.7895
Trunk ODU: Alarm Indication Signal
NOTIFICATION-TYPE    

companionCardMissing 1.3.6.1.4.1.3607.6.10.30.0.7900
Companion Card Missing
NOTIFICATION-TYPE    

controlPlaneUnverifiedClearedAlarmsPresent 1.3.6.1.4.1.3607.6.10.30.0.7905
Control Plane Unverified Cleared Alarms Present
NOTIFICATION-TYPE    

powerConsumptionLimitHasCrossed 1.3.6.1.4.1.3607.6.10.30.0.7910
Power Consumption Limit Has Crossed
NOTIFICATION-TYPE    

masterKeyExchangeFailed 1.3.6.1.4.1.3607.6.10.30.0.7915
Master Key Exchange Failed
NOTIFICATION-TYPE    

unitHighTemperature 1.3.6.1.4.1.3607.6.10.30.0.7930
Unit High Temperature
NOTIFICATION-TYPE    

overTemperatureUnitProtected 1.3.6.1.4.1.3607.6.10.30.0.7935
Over Temperature Unit Protected
NOTIFICATION-TYPE    

seqMismatchCount 1.3.6.1.4.1.3607.6.10.30.0.7945
Sequence Mismatch Count
NOTIFICATION-TYPE    

keyProgramOnAlteraFpgaFailed 1.3.6.1.4.1.3607.6.10.30.0.7960
Key Program On Altera FPGA Failed
NOTIFICATION-TYPE    

duplicateNodeControllerDetected 1.3.6.1.4.1.3607.6.10.30.0.7970
Duplicate Node Controller Detected
NOTIFICATION-TYPE    

restorationInProg 1.3.6.1.4.1.3607.6.10.30.0.7975
Restoration in Progress
NOTIFICATION-TYPE    

ramanPumpsCalibrationProcedureIsRunning 1.3.6.1.4.1.3607.6.10.30.0.7980
Raman Calibration Running
NOTIFICATION-TYPE    

ramanPumpsCalibrationIsScheduledToRunInTheNextMinutes 1.3.6.1.4.1.3607.6.10.30.0.7985
Raman Calibration Pending
NOTIFICATION-TYPE    

odukTCM1AlarmIndicationSignal 1.3.6.1.4.1.3607.6.10.30.0.13100
ODUk: TCM1 Alarm Indication Signal
NOTIFICATION-TYPE    

odukTCM2AlarmIndicationSignal 1.3.6.1.4.1.3607.6.10.30.0.13105
ODUk: TCM2 Alarm Indication Signal
NOTIFICATION-TYPE    

odukLockedDefectTCM1 1.3.6.1.4.1.3607.6.10.30.0.13110
ODUk Locked Defect - TCM1
NOTIFICATION-TYPE    

odukLockedDefectTCM2 1.3.6.1.4.1.3607.6.10.30.0.13115
ODUk Locked Defect - TCM2
NOTIFICATION-TYPE    

otukLossOfFrame 1.3.6.1.4.1.3607.6.10.30.0.13120
OTUk: Loss Of Frame
NOTIFICATION-TYPE    

odukOpenConnectionIndicationTCM1 1.3.6.1.4.1.3607.6.10.30.0.13125
ODUk Open Connection Indication TCM1
NOTIFICATION-TYPE    

odukOpenConnectionIndicationTCM2 1.3.6.1.4.1.3607.6.10.30.0.13130
ODUk Open Connection Indication TCM2
NOTIFICATION-TYPE    

odukTrailTraceIdentifierMismatchTCM1 1.3.6.1.4.1.3607.6.10.30.0.13135
ODUk Trail Trace Identifier Mismatch TCM1
NOTIFICATION-TYPE    

odukTrailTraceIdentifierMismatchTCM2 1.3.6.1.4.1.3607.6.10.30.0.13140
ODUk Trail Trace Identifier Mismatch TCM2
NOTIFICATION-TYPE    

odukSignalFailureTCM1 1.3.6.1.4.1.3607.6.10.30.0.13145
ODUk Signal Failure - TCM1
NOTIFICATION-TYPE    

odukSignalFailureTCM2 1.3.6.1.4.1.3607.6.10.30.0.13150
ODUk Signal Failure - TCM2
NOTIFICATION-TYPE    

odukSignalDegradeTCM1 1.3.6.1.4.1.3607.6.10.30.0.13155
ODUk Signal Degrade - TCM1
NOTIFICATION-TYPE    

odukSignalDegradeTCM2 1.3.6.1.4.1.3607.6.10.30.0.13160
ODUk Signal Degrade - TCM2
NOTIFICATION-TYPE    

lossOfChannel 1.3.6.1.4.1.3607.6.10.30.0.13165
Loss of Channel
NOTIFICATION-TYPE    

fecMismatch 1.3.6.1.4.1.3607.6.10.30.0.13170
FEC Mismatch
NOTIFICATION-TYPE    

timSectionMonitorTraceIdentifierMismatchFailure 1.3.6.1.4.1.3607.6.10.30.0.13175
TIM Section Monitor - Trace Identifier Mismatch Failure
NOTIFICATION-TYPE    

automaticLaserShutdown 1.3.6.1.4.1.3607.6.10.30.0.13180
Automatic Laser Shutdown
NOTIFICATION-TYPE    

shutterInsertionLossVariationDegradeLow 1.3.6.1.4.1.3607.6.10.30.0.13200
Shutter Insertion Loss Variation Degrade Low
NOTIFICATION-TYPE    

opticalChannelDeactivationFailure 1.3.6.1.4.1.3607.6.10.30.0.13205
Optical Channel de-activation failure
NOTIFICATION-TYPE    

shutterInsertionLossVariationDegradeHigh 1.3.6.1.4.1.3607.6.10.30.0.13210
Shutter Insertion Loss Variation Degrade High
NOTIFICATION-TYPE    

networkTopologyIncomplete 1.3.6.1.4.1.3607.6.10.30.0.13215
Network Topology Incomplete
NOTIFICATION-TYPE    

pluginModuleCommunicationFailure 1.3.6.1.4.1.3607.6.10.30.0.13220
Plug-in Module Communication Failure
NOTIFICATION-TYPE    

opticalNetworkTypeMismatch 1.3.6.1.4.1.3607.6.10.30.0.13225
Optical Network Type Mismatch
NOTIFICATION-TYPE    

opticalPowerDegradeLow 1.3.6.1.4.1.3607.6.10.30.0.13230
Optical Power Degrade Low
NOTIFICATION-TYPE    

automaticPowerControlFailure 1.3.6.1.4.1.3607.6.10.30.0.13235
Automatic Power Control Failure
NOTIFICATION-TYPE    

opticalPowerDegradeHigh 1.3.6.1.4.1.3607.6.10.30.0.13240
Optical Power Degrade High
NOTIFICATION-TYPE    

automaticPowerControlDisabled 1.3.6.1.4.1.3607.6.10.30.0.13245
Automatic Power Control Disabled
NOTIFICATION-TYPE    

opticalPowerFailureLow 1.3.6.1.4.1.3607.6.10.30.0.13250
Optical Power Failure Low
NOTIFICATION-TYPE    

ringIdMismatch 1.3.6.1.4.1.3607.6.10.30.0.13255
Ring Id Mismatch
NOTIFICATION-TYPE    

opticalPowerFailureHigh 1.3.6.1.4.1.3607.6.10.30.0.13260
Optical Power Failure High
NOTIFICATION-TYPE    

lossOfContinuity 1.3.6.1.4.1.3607.6.10.30.0.13270
Loss Of Continuity
NOTIFICATION-TYPE    

variableOpticalAttenuatorDegradeLow 1.3.6.1.4.1.3607.6.10.30.0.13280
Variable Optical Attenuator Degrade Low
NOTIFICATION-TYPE    

variableOpticalAttenuatorDegradeHigh 1.3.6.1.4.1.3607.6.10.30.0.13290
Variable Optical Attenuator Degrade High
NOTIFICATION-TYPE    

variableOpticalAttenuatorFailureLow 1.3.6.1.4.1.3607.6.10.30.0.13300
Variable Optical Attenuator Failure Low
NOTIFICATION-TYPE    

variableOpticalAttenuatorFailureHigh 1.3.6.1.4.1.3607.6.10.30.0.13310
Variable Optical Attenuator Failure High
NOTIFICATION-TYPE    

laserBiasDegrade 1.3.6.1.4.1.3607.6.10.30.0.13320
Laser Bias Degrade
NOTIFICATION-TYPE    

laserBiasFailure 1.3.6.1.4.1.3607.6.10.30.0.13330
aser Bias Failure
NOTIFICATION-TYPE    

laserTemperatureDegrade 1.3.6.1.4.1.3607.6.10.30.0.13340
Laser Temperature Degrade
NOTIFICATION-TYPE    

opticalAmplifierGainDegradeLow 1.3.6.1.4.1.3607.6.10.30.0.13350
Optical Amplifier Gain Degrade Low
NOTIFICATION-TYPE    

opticalAmplifierGainDegradeHigh 1.3.6.1.4.1.3607.6.10.30.0.13360
Optical Amplifier Gain Degrade High
NOTIFICATION-TYPE    

opticalAmplifierGainFailureLow 1.3.6.1.4.1.3607.6.10.30.0.13370
Optical Amplifier Gain Failure Low
NOTIFICATION-TYPE    

opticalAmplifierGainFailureHigh 1.3.6.1.4.1.3607.6.10.30.0.13380
Optical Amplifier Gain Failure High
NOTIFICATION-TYPE    

opticalChannelConnectionFailure 1.3.6.1.4.1.3607.6.10.30.0.13390
Optical Channel connection failure
NOTIFICATION-TYPE    

opticalChannelIncomplete 1.3.6.1.4.1.3607.6.10.30.0.13395
Optical Channel Incomplete
NOTIFICATION-TYPE    

opticalChannelActivationFailure 1.3.6.1.4.1.3607.6.10.30.0.13400
Optical Channel activation failure
NOTIFICATION-TYPE    

laserAutoPowerReduction 1.3.6.1.4.1.3607.6.10.30.0.13410
Laser Auto Power Reduction
NOTIFICATION-TYPE    

caseTemperatureDegrade 1.3.6.1.4.1.3607.6.10.30.0.13420
Case Temperature Degrade
NOTIFICATION-TYPE    

fiberTemperatureDegrade 1.3.6.1.4.1.3607.6.10.30.0.13430
Fiber Temperature Degrade
NOTIFICATION-TYPE    

shutterOpen 1.3.6.1.4.1.3607.6.10.30.0.13440
Shutter Open
NOTIFICATION-TYPE    

awgTemperatureDegrade 1.3.6.1.4.1.3607.6.10.30.0.13450
AWG Temperature Degrade
NOTIFICATION-TYPE    

awgTemperatureFailure 1.3.6.1.4.1.3607.6.10.30.0.13460
AWG Temperature Failure
NOTIFICATION-TYPE    

awgOverTemperature 1.3.6.1.4.1.3607.6.10.30.0.13470
AWG Over-Temperature
NOTIFICATION-TYPE    

opticalAmplifierInitialization 1.3.6.1.4.1.3607.6.10.30.0.13480
Optical Amplifier Initialization
NOTIFICATION-TYPE    

awgWarmUp 1.3.6.1.4.1.3607.6.10.30.0.13490
AWG Warm Up
NOTIFICATION-TYPE    

incSigloss 1.3.6.1.4.1.3607.6.10.30.0.13510
Incoming Signal Loss on Fibre Channel Interface
NOTIFICATION-TYPE    

incSyncloss 1.3.6.1.4.1.3607.6.10.30.0.13515
Incoming Synchronization Loss on Fibre Channel Interface
NOTIFICATION-TYPE    

incGfpOutOfFrame 1.3.6.1.4.1.3607.6.10.30.0.13520
Out Of Frame Detected by GFP Receiver
NOTIFICATION-TYPE    

incGfpSigLoss 1.3.6.1.4.1.3607.6.10.30.0.13525
Client Signal Loss Frames Detected by GFP Receiver
NOTIFICATION-TYPE    

incGfpSyncLoss 1.3.6.1.4.1.3607.6.10.30.0.13530
Client Sychronization Loss Frames Detected by GFP Receiver
NOTIFICATION-TYPE    

node454Group 1.3.6.1.4.1.3607.6.10.10.10.10
The group for node related objects
OBJECT-GROUP    

alarm454Group 1.3.6.1.4.1.3607.6.10.10.10.20
The group for node related objects
OBJECT-GROUP    

event454Group 1.3.6.1.4.1.3607.6.10.10.10.30
The notifications for Cisco ONS 15454
NOTIFICATION-GROUP    

cerent454CommonGroup 1.3.6.1.4.1.3607.6.10.10.10.40
The objects for storing all the current alarms
OBJECT-GROUP    

cerentThresholdGroup 1.3.6.1.4.1.3607.6.10.10.10.50
The objects for storing all the current alarms
OBJECT-GROUP    

event454DeprecatedGroup 1.3.6.1.4.1.3607.6.10.10.10.60
The notifications for Cisco ONS 15454 that have been deprecated
NOTIFICATION-GROUP    

reportedAlarm454Group 1.3.6.1.4.1.3607.6.10.10.10.80
The group for reported alarm objects
OBJECT-GROUP    

cerent454BasicCompliance 1.3.6.1.4.1.3607.6.10.10.20.10
The basic implementation requirements for Cisco ONS 15454 MIB
MODULE-COMPLIANCE