CDX-6500-COMMON-MIB

File: CDX-6500-COMMON-MIB.mib (153824 bytes)

Imported modules

RFC1155-SMI RFC-1212

Imported symbols

mgmt NetworkAddress IpAddress
Counter Gauge TimeTicks
enterprises OBJECT-TYPE

Defined Types

Counter16  
INTEGER 0..65535    

DisplayString  
OCTET STRING    

Cdx6500SNMPTrapThrottleEntry  
SEQUENCE    
  cdx6500SNMPTrapNumber INTEGER
  cdx6500SNMPMaxNumOfTraps INTEGER
  cdx6500SNMPThrottlingPeriod INTEGER
  cdx6500SNMPNewTrapLevel INTEGER
  cdx6500SNMPEntryStatus INTEGER

Cdx6500NMNPIinventEntry  
SEQUENCE    
  cdx6500NMNPIinventBoard INTEGER
  cdx6500NMNPIinventType DisplayString
  cdx6500NMNPIinventPorts INTEGER
  cdx6500NMNPIinventStatus DisplayString
  cdx6500NMNPIinventSerial DisplayString
  cdx6500NMNPIinventAssy DisplayString
  cdx6500NMNPIinventRev DisplayString
  cdx6500NMNPIinventDIM1 DisplayString
  cdx6500NMNPIinventDIM2 DisplayString

Cdx6500NMNPIinventPortConfigEntry  
SEQUENCE    
  cdx6500NMNPIinventPortNum INTEGER
  cdx6500NMNPIinventPortConfig DisplayString

Cdx6500NMNPSresetStatEntry  
SEQUENCE    
  cdx6500NMNPSresetStatPort INTEGER
  cdx6500NMNPSresetStatStatus INTEGER

Cdx6500NMNPSstatsEntry  
SEQUENCE    
  cdx6500NMNPSstatsBoard INTEGER
  cdx6500NMNPSstatsbuffDataAvail INTEGER
  cdx6500NMNPSstatsbuffDataUse INTEGER
  cdx6500NMNPSstatsbuffDataGauge Gauge
  cdx6500NMNPSstatsmemEprom INTEGER
  cdx6500NMNPSstatsmemDram INTEGER
  cdx6500NMNPSstatsmemFlash INTEGER
  cdx6500NMNPSstatscpuUtil INTEGER
  cdx6500NMNPSstatsMaxcpuUtil INTEGER
  cdx6500NMNPSstatsMaxcpuUtilTime DisplayString

Cdx6500NMReportEntry  
SEQUENCE    
  cdx6500reptIndex INTEGER
  cdx6500reptEvent DisplayString

Cdx6500PPSTallPortsEntry  
SEQUENCE    
  cdx6500allportsPortNum INTEGER
  cdx6500allportsPortType INTEGER
  cdx6500allportsPortStatus INTEGER
  cdx6500allportsPortState DisplayString
  cdx6500allportsPortSpeed INTEGER
  cdx6500allportsUtilizationIn INTEGER
  cdx6500allportsUtilizationOut INTEGER
  cdx6500allportsCharInTot Counter
  cdx6500allportsCharOutTot Counter
  cdx6500allportsPktInTot Counter
  cdx6500allportsPktOutTot Counter
  cdx6500allportsFrameInTot Counter
  cdx6500allportsFrameOutTot Counter
  cdx6500allportsPktsQueued INTEGER
  cdx6500allportsCharsInPerSec INTEGER
  cdx6500allportsCharsOutPerSec INTEGER
  cdx6500allportsPktsInPerSec INTEGER
  cdx6500allportsPktsOutPerSec INTEGER
  cdx6500allportsFramesInPerSec INTEGER
  cdx6500allportsFramesOutPerSec INTEGER
  cdx6500allportsOverrunErrors Counter16
  cdx6500allportsUnderrunErrors Counter16
  cdx6500allportsCRCErrors Counter16
  cdx6500allportsParityErrors Counter16
  cdx6500allportsFramingErrors Counter16
  cdx6500allportsBootPort INTEGER
  cdx6500allportsPortControlStatus INTEGER

Cdx6500SPSTallStationsEntry  
SEQUENCE    
  cdx6500allstationsPortNum INTEGER
  cdx6500allstationsStnNum INTEGER
  cdx6500allstationsStnType DisplayString
  cdx6500allstationsStnStatus INTEGER
  cdx6500allstationsStnState DisplayString
  cdx6500allstationsUtilizationIn INTEGER
  cdx6500allstationsUtilizationOut INTEGER
  cdx6500allstationsCharInTot Counter
  cdx6500allstationsCharOutTot Counter
  cdx6500allstationsPktInTot Counter
  cdx6500allstationsPktOutTot Counter
  cdx6500allstationsFrameInTot Counter
  cdx6500allstationsFrameOutTot Counter
  cdx6500allstationsPktsQueued INTEGER
  cdx6500allstationsCharsInPerSec INTEGER
  cdx6500allstationsCharsOutPerSec INTEGER
  cdx6500allstationsPktsInPerSec INTEGER
  cdx6500allstationsPktsOutPerSec INTEGER
  cdx6500allstationsFramesInPerSec INTEGER
  cdx6500allstationsFramesOutPerSec INTEGER
  cdx6500allstationsBootStation INTEGER
  cdx6500allstationsDisableStation INTEGER
  cdx6500allstationsEnableStation INTEGER
  cdx6500allstationsBusyOutStation INTEGER

Cdx6500GCTRouteSelectionEntry  
SEQUENCE    
  cdx6500RoutSVCEntryNumber INTEGER
  cdx6500RoutSVCAddress INTEGER
  cdx6500RoutSVCDestination1 DisplayString
  cdx6500RoutSVCPriority1 INTEGER
  cdx6500RoutSVCDestination2 DisplayString
  cdx6500RoutSVCPriority2 INTEGER
  cdx6500RoutSVCDestination3 DisplayString
  cdx6500RoutSVCPriority3 INTEGER
  cdx6500RoutSVCDestination4 DisplayString
  cdx6500RoutSVCPriority4 INTEGER
  cdx6500RoutSVCDestination5 DisplayString
  cdx6500RoutSVCPriority5 INTEGER
  cdx6500RoutSVCDestination6 DisplayString
  cdx6500RoutSVCPriority6 INTEGER
  cdx6500RoutSVCDestination7 DisplayString
  cdx6500RoutSVCPriority7 INTEGER
  cdx6500RoutSVCDestination8 DisplayString
  cdx6500RoutSVCPriority8 INTEGER
  cdx6500RoutSVCAddress1 DisplayString

Cdx6500GCTPVCSetupEntry  
SEQUENCE    
  cdx6500PVCSetupEntryNumber INTEGER
  cdx6500PVCSetupSource DisplayString
  cdx6500PVCSetupDestination DisplayString

Cdx6500CfgMnemonicEntry  
SEQUENCE    
  cdx6500mnemEntryNum INTEGER
  cdx6500mnemName DisplayString
  cdx6500mnemx28Cmd DisplayString

Cdx6500GCTNUIPasswordEntry  
SEQUENCE    
  cdx6500NUITEntryNumber INTEGER
  cdx6500NUITAcctName DisplayString
  cdx6500NUITPasswd DisplayString
  cdx6500NUITPADPromptNum INTEGER

Cdx6500GCTSoftwareKeyEntry  
SEQUENCE    
  cdx6500CSISSoftKeyEntryNumber INTEGER
  cdx6500CSISSoftKeyValue DisplayString

Cdx6500OSTCSISOptionStatEntry  
SEQUENCE    
  cdx6500CSISOptionNumber INTEGER
  cdx6500CSISMaxAllowed INTEGER
  cdx6500CSISNumUsed INTEGER
  cdx6500CSISOptionAuth INTEGER

Cdx6500OSTCSISPortUsageEntry  
SEQUENCE    
  cdx6500CSISPortNumber INTEGER
  cdx6500CSISPortAuth INTEGER

Cdx6500StatSVCEntry  
SEQUENCE    
  cdx6500StatSVCIndex INTEGER
  cdx6500StatSVCCallingChannel DisplayString
  cdx6500StatSVCCalledChannel DisplayString
  cdx6500StatSVCReverseCharge INTEGER
  cdx6500StatSVCFastSelect INTEGER
  cdx6500StatSVCNetUserIdentification INTEGER
  cdx6500StatSVCClosedUserGroup INTEGER
  cdx6500StatSVCConnectionUPTime DisplayString

Cdx6500CreatePortAndStationEntry  
SEQUENCE    
  cdx6500PortNumber INTEGER
  cdx6500CreatePortType INTEGER
  cdx6500CreateStation INTEGER

Cdx6500T3E3ContEntry  
SEQUENCE    
  t3e3ContPortNumber INTEGER
  t3e3ContPortControl INTEGER

Defined Values

codex 1.3.6.1.4.1.449
OBJECT IDENTIFIER    

cdxProductSpecific 1.3.6.1.4.1.449.2
OBJECT IDENTIFIER    

cdx6500 1.3.6.1.4.1.449.2.1
OBJECT IDENTIFIER    

cdx6500NodeMgmt 1.3.6.1.4.1.449.2.1.1
OBJECT IDENTIFIER    

cdx6500NMSNMPGroup 1.3.6.1.4.1.449.2.1.1.1
OBJECT IDENTIFIER    

cdx6500NMNodeParametersGroup 1.3.6.1.4.1.449.2.1.1.2
OBJECT IDENTIFIER    

cdx6500NMDiagnosticsGroup 1.3.6.1.4.1.449.2.1.1.3
OBJECT IDENTIFIER    

cdx6500NMControlsGroup 1.3.6.1.4.1.449.2.1.1.4
OBJECT IDENTIFIER    

cdx6500NMDLSVGroup 1.3.6.1.4.1.449.2.1.1.5
OBJECT IDENTIFIER    

cdx6500Configuration 1.3.6.1.4.1.449.2.1.2
OBJECT IDENTIFIER    

cdx6500CfgProtocolGroup 1.3.6.1.4.1.449.2.1.2.1
OBJECT IDENTIFIER    

cdx6500PCTPortProtocolGroup 1.3.6.1.4.1.449.2.1.2.1.1
OBJECT IDENTIFIER    

cdx6500CfgGeneralGroup 1.3.6.1.4.1.449.2.1.2.2
OBJECT IDENTIFIER    

cdx6500Statistics 1.3.6.1.4.1.449.2.1.3
OBJECT IDENTIFIER    

cdx6500StatProtocolGroup 1.3.6.1.4.1.449.2.1.3.1
OBJECT IDENTIFIER    

cdx6500StatOtherStatsGroup 1.3.6.1.4.1.449.2.1.3.2
OBJECT IDENTIFIER    

cdx6500StatTFTPGroup 1.3.6.1.4.1.449.2.1.3.3
OBJECT IDENTIFIER    

cdx6500StatNetworkSvcsGroup 1.3.6.1.4.1.449.2.1.3.4
OBJECT IDENTIFIER    

cdx6500PSTPortProtocolGroup 1.3.6.1.4.1.449.2.1.3.1.1
OBJECT IDENTIFIER    

cdx6500PSTStationProtocolGroup 1.3.6.1.4.1.449.2.1.3.1.3
OBJECT IDENTIFIER    

cdx6500PSTLANConnectionGroup 1.3.6.1.4.1.449.2.1.3.1.6
OBJECT IDENTIFIER    

cdx6500Controls 1.3.6.1.4.1.449.2.1.4
OBJECT IDENTIFIER    

cdx6500ContTFTP 1.3.6.1.4.1.449.2.1.4.2
OBJECT IDENTIFIER    

cdx6500statControls 1.3.6.1.4.1.449.2.1.4.4
OBJECT IDENTIFIER    

cdx6500ContFlash 1.3.6.1.4.1.449.2.1.4.21
OBJECT IDENTIFIER    

cdx6500SNMPPrimUDPChan 1.3.6.1.4.1.449.2.1.1.1.1
The primary UDP port used by the SNMP Agent has a default value of 161.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..3)  

cdx6500SNMPSecUDPChan 1.3.6.1.4.1.449.2.1.1.1.2
The secondary UDP port used by the SNMP Agent has a default value of 162.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..3)  

cdx6500SNMPAgentTimer 1.3.6.1.4.1.449.2.1.1.1.3
An internal timer used by the SNMP agent, unit is a 20 ms tick.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..255  

cdx6500SNMPTrapEnable 1.3.6.1.4.1.449.2.1.1.1.4
A control object to disable or enable the SNMP agent's trap send capability. newvalDisable : same functionality as 'disable', new enumeration added for RFC1155 compatibility.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER disable(0), enable(1), newvalDisable(50)  

cdx6500SNMPBootAgent 1.3.6.1.4.1.449.2.1.1.1.5
A control object. Setting to value `boot' will cause the SNMP agent to boot.
Status: mandatory Access: write-only
OBJECT-TYPE    
  INTEGER boot(1), noBoot(2)  

cdx6500SNMPResetStats 1.3.6.1.4.1.449.2.1.1.1.6
A control object, which when set to value `reset', will cause the SNMP agent to reset all its statistics.
Status: mandatory Access: write-only
OBJECT-TYPE    
  INTEGER reset(1), noReset(2)  

cdx6500SNMPLastTrap 1.3.6.1.4.1.449.2.1.1.1.7
The interesting information portion of the last trap PDU issued by the SNMP Agent.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..128)  

cdx6500SNMPGenTrapsType 1.3.6.1.4.1.449.2.1.1.1.8
Choice between generic traps as defined in RFC or correponding enterprise specific traps to be generated by the node. This attribute is applicable only when generic traps are being generated and there exists a corresponding enterprise specific trap.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER rfc(1), enterpriseSpecific(2)  

cdx6500SNMPTrapThrottleTable 1.3.6.1.4.1.449.2.1.1.1.9
Throttling table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Cdx6500SNMPTrapThrottleEntry

cdx6500SNMPTrapThrottleEntry 1.3.6.1.4.1.449.2.1.1.1.9.1
Entry representing throttling parameters.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Cdx6500SNMPTrapThrottleEntry  

cdx6500SNMPTrapNumber 1.3.6.1.4.1.449.2.1.1.1.9.1.1
Trap number to be throttled.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1000..2147483647  

cdx6500SNMPMaxNumOfTraps 1.3.6.1.4.1.449.2.1.1.1.9.1.2
Number of traps allowed to be generated in the throttling period.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..65535  

cdx6500SNMPThrottlingPeriod 1.3.6.1.4.1.449.2.1.1.1.9.1.3
Throttling time period in seconds. Value 0 means trap is not throttled.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..65535  

cdx6500SNMPNewTrapLevel 1.3.6.1.4.1.449.2.1.1.1.9.1.4
New severity level for the trap.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER unchanged(1), high(2), medium(3), low(5)  

cdx6500SNMPEntryStatus 1.3.6.1.4.1.449.2.1.1.1.9.1.5
Table row status. Setting the value to deleted removes the entry from the table.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER active(1), deleted(2)  

cdx6500SNMPSetControl 1.3.6.1.4.1.449.2.1.1.1.10
Snmp Set operation control off : snmp set operation is not allowed on : snmp set operation is allowed.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER off(1), on(2)  

cdx6500SNMPIpAddress 1.3.6.1.4.1.449.2.1.1.1.11
IP address for this node.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString  

cdx6500NMNPconfig 1.3.6.1.4.1.449.2.1.1.2.1
OBJECT IDENTIFIER    

cdx6500NMNPinvent 1.3.6.1.4.1.449.2.1.1.2.2
OBJECT IDENTIFIER    

cdx6500NMNPstats 1.3.6.1.4.1.449.2.1.1.2.3
OBJECT IDENTIFIER    

cdx6500NMNPCnodeName 1.3.6.1.4.1.449.2.1.1.2.1.1
This parameter identifies the node with a name, which appears at the top of control terminal menus and reports. Range is 0 to 8 alphanumeric characters.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..8)  

cdx6500NMNPCnodeNum 1.3.6.1.4.1.449.2.1.1.2.1.2
The node number identifies the node for X.25 routing purposes to prevent routing loops.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..65535  

cdx6500NMNPCnodeAddress 1.3.6.1.4.1.449.2.1.1.2.1.3
The node address specifies the main part of the network address for calls destined within this node: PAD port or node resource (for example, control port) calls. Individual subaddresses specify exact destination.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..13)  

cdx6500NMNPCchassis 1.3.6.1.4.1.449.2.1.1.2.1.4
This parameters identifies the type of chassis that this node is residing in. This is necessary in order to correctly interpret the fan and power supply status signals. newvalStandalone : same functionality as 'standalone', new enumeration added for RFC1155 compatibility.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER standalone(0), modulus8(1), modulus18(2), modulus9(3), modulus19(4), chassis6520(5), chassis6560(6), newvalStandalone(50)  

cdx6500NMNPCdate 1.3.6.1.4.1.449.2.1.1.2.1.5
The node date used for date stamps of events and traps. The format of the string is yyyymmmdd, year: four digits, month: first three letters of the month, day: 01..31.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(9)  

cdx6500NMNPCtime 1.3.6.1.4.1.449.2.1.1.2.1.6
The node time used for time stamps of events and traps. The format of the string is hhmmss, hour: 00..23, minute 00..59, second: 00..59.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(4)  

cdx6500NMNPCportUtil 1.3.6.1.4.1.449.2.1.1.2.1.7
Port Utilization Threshold (%). This parameter sets the alarm level for traffic on every port in a node. The traffic is checked over a 64-second interval to give an average (in characters per second). This is compared to the port's clock rate and a utilization factor is produced. If the percent of utiliaztion exceeds the setting, an alarm is generated. Port utilization records are kept for each port and the port in question is noted in the report.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 10..99  

cdx6500NMNPCbuffUtil 1.3.6.1.4.1.449.2.1.1.2.1.8
Buffer Utilization Threshold (%). This parameter sets the alarm level for data buffers. When data passes through a node, buffers provide temporary storage. If the number of buffers used exceeds the specified percentage of available storage, an alarm is generated.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 10..99  

cdx6500NMNPCcpuUtil 1.3.6.1.4.1.449.2.1.1.2.1.9
CPU Utilization Threshold (%). If the CPU is not processing data, it is running diagnostic checks. It is never idle. This parameter specifies the amount of time spent performing non-diagnostic functions as a percentage of the total time. If this percentage exceeds the threshold, an alarm is generated.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 10..99  

cdx6500NMNPCportErr 1.3.6.1.4.1.449.2.1.1.2.1.10
Port Error Threshold. This threshold specifies the number of port errors (such as parity or framing errors) that can be detected before a medium severity alarm is generated. For example, if this parameter is set to 10, an alarm is sent when 10 errors are detected, another alarm is sent when the 20th error is detected, etc.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..255  

cdx6500NMNPCalarmTmr 1.3.6.1.4.1.449.2.1.1.2.1.11
Alarm Threshold Timer. This parameter prevents a node from sending threshold alarms too frequently. If a node generates an alarm the threshold alarm timer is started and the node is not allowed to generate the same alarm until the timer has expired. This controls the frequency of alarm reporting.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 15..255  

cdx6500NMNPCmaxRoutHops 1.3.6.1.4.1.449.2.1.1.2.1.12
Maximum Routing Hops.This parameter specifies the maximum number of nodes a call may pass through before reaching its destination.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 2..15  

cdx6500NMNPCctpSubAddr 1.3.6.1.4.1.449.2.1.1.2.1.13
This parameter specifies the Control Port (CTP) Subaddress. Calls with network address composed of the node address and this subaddress will be routed to the control port in this node. No routing table entry is needed.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..3)  

cdx6500NMNPCctpIdleTime 1.3.6.1.4.1.449.2.1.1.2.1.14
Control Port Idle Disconnect Time (minutes). This specifies how many minutes of inactivity can occur before the control terminal is automatically disconnected
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..255  

cdx6500NMNPCalmDist 1.3.6.1.4.1.449.2.1.1.2.1.15
This object has been replaced by cdx6500NMNPCalmDistrib.
Status: deprecated Access: read-only
OBJECT-TYPE    
  INTEGER deprecatedObj(1)  

cdx6500NMNPCalmMmem 1.3.6.1.4.1.449.2.1.1.2.1.16
Alarm Printer Mnemonic. This specifies the mnemonic name for the destination of alarms sent by the node (if Alarm Distribution = PRIN). This destination is usually a printer or a personal computer. To prevent any alarms from being sent, set this to blank.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..8)  

cdx6500NMNPCalmSelect 1.3.6.1.4.1.449.2.1.1.2.1.17
This object has been replaced by cdx6500NMNPCalmSelection.
Status: deprecated Access: read-only
OBJECT-TYPE    
  INTEGER deprecatedObj(1)  

cdx6500NMNPCbroadPortSubad 1.3.6.1.4.1.449.2.1.1.2.1.18
This specifies the broadcast port subaddress for this node. Calls with network address composed of the node address and this subaddress will be routed to the broadcast port in this node. No routing table entry is needed.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..3)  

cdx6500NMNPCnoBroadNets 1.3.6.1.4.1.449.2.1.1.2.1.19
Number of Broadcast Nets. This specifies the number of Broadcast Networks to which this node can send broadcast messages. A value of 0 will disable broadcast functions.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..100  

cdx6500NMNPCnoBroadInCh 1.3.6.1.4.1.449.2.1.1.2.1.20
Number of Broadcast Input Channels. This specifies the number of simultaneous broadcast messages that can be received.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..10  

cdx6500NMNPCbillMnem 1.3.6.1.4.1.449.2.1.1.2.1.21
When billing records need to be printed, the node will use this mnemonic to call and send the records to this destination. This location is usually a printer used to print billing records.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..8)  

cdx6500NMNPCbillThresh 1.3.6.1.4.1.449.2.1.1.2.1.22
When the number of billing records queued up equals this threshold, a call will be placed to the logging device to dump the billing records.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..99  

cdx6500NMNPCmaxBill 1.3.6.1.4.1.449.2.1.1.2.1.23
This is the maximum number of billing records the node will be allowed to store to be printed. Billing records created after this maximum is reached will be lost.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..200  

cdx6500NMNPCbillTimer 1.3.6.1.4.1.449.2.1.1.2.1.24
If billing records have been stored for printing for this amount of time (in minutes) without reaching the threshold, a call will be made so that they can be printed.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..65535  

cdx6500NMNPCpvcBill 1.3.6.1.4.1.449.2.1.1.2.1.25
At this interval the billing records will be gathered and printed for all of the PVC's in the node that have billing turned on.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..65535  

cdx6500NMNPCmaxCalls 1.3.6.1.4.1.449.2.1.1.2.1.26
Limiting the number of calls allowed in the node will eliminate data loss in extreme traffic conditions.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..2000  

cdx6500NMNPCpadBulletin 1.3.6.1.4.1.449.2.1.1.2.1.27
PAD Bulletin Message. Specifies the message that appears when a terminal connects to PAD port and enters Command Mode. To have no message appear, select blank.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

cdx6500NMNPCpadBanner 1.3.6.1.4.1.449.2.1.1.2.1.28
PAD Banner Message. Specifies the message PAD ports send to attached terminals when they enter Command Mode. These special characters can be used to display certain information in the PAD Banner Message. A Node address C Channel Number G Group sub-address N Node Name P Port Number S Sub-address T Time V Software revision If the character following the % symbol is not one of the above, both the % and following character are discarded. The caret (^) is used as an escape character to tell the PAD to send control characters. The character following the caret is converted to a control character and is sent to the PAD port for output. The caret is discarded unless it is entered twice (^^).
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..63)  

cdx6500NMNPCdcpFac 1.3.6.1.4.1.449.2.1.1.2.1.29
This defines the facility used to carry DCP information at call setup and reconnection time in Call Request and Call Accept packets through the 6500 network. Change the value only if it interferes with some other private network facility.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 201..254  

cdx6500NMNPCtrafficPri 1.3.6.1.4.1.449.2.1.1.2.1.30
Traffic Priority. This is the default traffic priority to be used on the node. newvalLow : same functionality as 'low', new enumeration added for RFC1155 compatibility.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER low(0), med(1), high(2), exp(3), newvalLow(50)  

cdx6500NMNPCtrafficStep 1.3.6.1.4.1.449.2.1.1.2.1.31
Traffic Priority Step. This specifies the number of packets to be transmitted for each lower priority packet transmitted.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..65535  

cdx6500NMNPCpropProtId 1.3.6.1.4.1.449.2.1.1.2.1.32
This is the Codex Proprietary Protocol ID. Its value is put in the first byte of the Protocol Identifier field of the CUD in the Call Request packets for protocols that have not been assigned a standardized value by the CCITT.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 192..255  

cdx6500NMNPClanSubAddr 1.3.6.1.4.1.449.2.1.1.2.1.33
Calls with network address composed of the node address and this subaddress will be routed to a LAN Connection in this node.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..3)  

cdx6500NMNPCMaxFrameSize 1.3.6.1.4.1.449.2.1.1.2.1.34
The largest datalink level frame that will ever be received on any link. On WAN links this does not include space that is reserved internally for trailers.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..65535  

cdx6500NMNPCCodexGroupFacility 1.3.6.1.4.1.449.2.1.1.2.1.35
This is the facility used in call packets on Codex 6500 links for passing CODEX PRIVATE facilities other than Hop Count and DCP facilities between 4.xx nodes. This should be the SAME on all nodes in the network. It need only be changed if it interferes with some other private network facility.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 202..254  

cdx6500NMNPCalmDistrib 1.3.6.1.4.1.449.2.1.1.2.1.36
Distribution of alarms is controlled by specifying: NONE - no alarm is sent \ CTP - send alarms to Control Port Terminal \ PRIN - send alarms to Printer Destination \ Any combination of above specified by summing (e.g. CTP+PRIN).
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(3..8)  

cdx6500NMNPCalmSelection 1.3.6.1.4.1.449.2.1.1.2.1.37
Alarm type reporting by the node: NONE - no alarms reported. HIGH - high severity alarms reported. MED - medium severity alarms reported. LOW - low severity alarms reported. CONN - connection events reported. CODE - alarms from Codex 6000 communication processors reported. Any combination of above specified by summing (e.g. HIGH+CONN+. . .).
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(3..27)  

cdx6500NMNPChopFacility 1.3.6.1.4.1.449.2.1.1.2.1.38
Hop Count Facility. This is the facility used in call packets on X.25 links with the INL option for network routing. This should be the SAME in all nodes in the network. It need only be changed if it interferes with some other private network facility.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 200..254  

cdx6500NMNPCnumNccpDevices 1.3.6.1.4.1.449.2.1.1.2.1.39
This is the number of NCCP devices.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..2000  

cdx6500NMNPCmaxCallid 1.3.6.1.4.1.449.2.1.1.2.1.40
This is the maximum number of Call id numbers that go in the Calling Identifier table. This table can have a maximum of 512 entries. Each entry of 30 digits.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..200  

cdx6500NMNPIproductType 1.3.6.1.4.1.449.2.1.1.2.2.1
Identifies a general class of feature set for the product, e.g. 6504PLUS Asynchronous PAD or 6520 Branch Node
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

cdx6500NMNPIsoftwareSrc 1.3.6.1.4.1.449.2.1.1.2.2.2
The source of software currently running on the node. prom - CPU running from code in PROM. download - CPU downloading code into RAM. promLoadingRAM - CPU running from code in RAM. newvalProm - same functionality as 'prom', new enumeration added for RFC1155 compatibility.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER prom(0), download(1), promLoadingRAM(2), newvalProm(50)  

cdx6500NMNPIserialNum 1.3.6.1.4.1.449.2.1.1.2.2.3
The serial number of the motherboard.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cdx6500NMNPIpromRevision 1.3.6.1.4.1.449.2.1.1.2.2.4
The PROM software revision.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

cdx6500NMNPIdlCodeRevision 1.3.6.1.4.1.449.2.1.1.2.2.5
The downloaded software revision. Applicable to 6500 platforms.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString  

cdx6500NMNPIdlCodeSource 1.3.6.1.4.1.449.2.1.1.2.2.6
The source of downloaded software. Applicable to 6500 platforms.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString  

cdx6500NMNPIdlCodeSize 1.3.6.1.4.1.449.2.1.1.2.2.7
The size of downloaded software in bytes. Applicable to 6500 platforms.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER  

cdx6500NMNPIflashStatus 1.3.6.1.4.1.449.2.1.1.2.2.8
The status of use of flash memory. Applicable only to 6500 platforms. newvalEnabled : same functionality as 'enabled', new enumeration added for RFC1155 compatibility.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER enabled(0), disabled(1), newvalEnabled(50)  

cdx6500NMNPIflashIdCur 1.3.6.1.4.1.449.2.1.1.2.2.9
Name and version of software stored in flash. This refers to the currently selected bank of flash when there is an alternate bank of flash installed.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

cdx6500NMNPIflashIdAlt 1.3.6.1.4.1.449.2.1.1.2.2.10
Name and version of software contained by the alternate bank of flash (if installed). Applicable to 6520 platforms.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString  

cdx6500NMNPIflashSizeCur 1.3.6.1.4.1.449.2.1.1.2.2.11
Size of software stored in flash. This refers to the currently selected bank of flash when there is an alternate bank of flash installed.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cdx6500NMNPIflashSizeAlt 1.3.6.1.4.1.449.2.1.1.2.2.12
Size of software in the alternate bank of flash (bytes). Applicable to 6520 platforms.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER  

cdx6500NMNPIinventTable 1.3.6.1.4.1.449.2.1.1.2.2.13
A list of the node's boards.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Cdx6500NMNPIinventEntry

cdx6500NMNPIinventEntry 1.3.6.1.4.1.449.2.1.1.2.2.13.1
Each entry contains a board number, board type, number of ports, status, and serial number.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Cdx6500NMNPIinventEntry  

cdx6500NMNPIinventBoard 1.3.6.1.4.1.449.2.1.1.2.2.13.1.1
The board number. This is used to index the boards in a node.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cdx6500NMNPIinventType 1.3.6.1.4.1.449.2.1.1.2.2.13.1.2
The board type. A description of the type of board.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

cdx6500NMNPIinventPorts 1.3.6.1.4.1.449.2.1.1.2.2.13.1.3
The number of I/O ports for this board.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cdx6500NMNPIinventStatus 1.3.6.1.4.1.449.2.1.1.2.2.13.1.4
The status of the board
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

cdx6500NMNPIinventSerial 1.3.6.1.4.1.449.2.1.1.2.2.13.1.5
The serial number of the board
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

cdx6500NMNPIinventAssy 1.3.6.1.4.1.449.2.1.1.2.2.13.1.6
The assembly number of the board
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

cdx6500NMNPIinventRev 1.3.6.1.4.1.449.2.1.1.2.2.13.1.7
The revision level of the board
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

cdx6500NMNPIinventDIM1 1.3.6.1.4.1.449.2.1.1.2.2.13.1.8
The type of interface specified by DIM 1.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

cdx6500NMNPIinventDIM2 1.3.6.1.4.1.449.2.1.1.2.2.13.1.9
The type of interface specified by DIM 2.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

cdx6500NMNPIinventPortConfigTable 1.3.6.1.4.1.449.2.1.1.2.2.14
A list of the node's Port Configuration.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Cdx6500NMNPIinventPortConfigEntry

cdx6500NMNPIinventPortConfigEntry 1.3.6.1.4.1.449.2.1.1.2.2.14.1
Each entry contains a port configuration.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Cdx6500NMNPIinventPortConfigEntry  

cdx6500NMNPIinventPortNum 1.3.6.1.4.1.449.2.1.1.2.2.14.1.1
The port number. This is used to index the ports in a node.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cdx6500NMNPIinventPortConfig 1.3.6.1.4.1.449.2.1.1.2.2.14.1.2
The port configuration on each board.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

cdx6500NMNPSevLastOccPower 1.3.6.1.4.1.449.2.1.1.2.3.1
The last time the node was turned on.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

cdx6500NMNPSevLastOccReset 1.3.6.1.4.1.449.2.1.1.2.3.2
The last time the reset button was pressed.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

cdx6500NMNPSevLastOccReboot 1.3.6.1.4.1.449.2.1.1.2.3.3
The last time the node was rebooted.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

cdx6500NMNPSevLastOccWDTimer 1.3.6.1.4.1.449.2.1.1.2.3.4
The last time the watch dog timer expired.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

cdx6500NMNPSevLastOccConfig 1.3.6.1.4.1.449.2.1.1.2.3.5
The last time the configuration memory was changed or downloaded.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

cdx6500NMNPSstatusFan 1.3.6.1.4.1.449.2.1.1.2.3.6
The operational status of the cooling fan. newvalNotMonitored : same functionality as 'notMonitored', new enumeration added for RFC1155 compatibility.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER notMonitored(0), operational(1), impaired(2), newvalNotMonitored(50)  

cdx6500NMNPSstatusPwrSy 1.3.6.1.4.1.449.2.1.1.2.3.7
The operational status of the power supply. This object is being replaced by cdx6500NMNPSstatusPowerSy. newvalNotMonitored : same functionality as 'notMonitored', new enumeration added for RFC1155 compatibility.
Status: deprecated Access: read-only
OBJECT-TYPE    
  INTEGER notMonitored(0), operational(1), impaired(2), newvalNotMonitored(50), notAvailable(100)  

cdx6500NMNPScmemSizeComp 1.3.6.1.4.1.449.2.1.1.2.3.8
Size of compressed configuration memory available (free) in bytes.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cdx6500NMNPScmemUseComp 1.3.6.1.4.1.449.2.1.1.2.3.9
Size of compressed configuration memory in use in bytes.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cdx6500NMNPScmemSizeUncomp 1.3.6.1.4.1.449.2.1.1.2.3.10
Size of uncompressed configuration memory available (free) in bytes.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cdx6500NMNPScmemUseUnComp 1.3.6.1.4.1.449.2.1.1.2.3.11
Size of uncompressed configuration memory in use in bytes.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cdx6500NMNPScallsInPlaceCur 1.3.6.1.4.1.449.2.1.1.2.3.12
Number of X.25 calls. The number of calls currently in place.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cdx6500NMNPScallsInPlaceMax 1.3.6.1.4.1.449.2.1.1.2.3.13
Number of X.25 calls gauge. The maximum number of calls since the last reset.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

cdx6500NMNPScallsPerSecCur 1.3.6.1.4.1.449.2.1.1.2.3.14
Rate of X.25 calls. The number of calls/sec. currently in place.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cdx6500NMNPScallsPerSecMax 1.3.6.1.4.1.449.2.1.1.2.3.15
Rate of X.25 calls gauge. The maximum number of calls/sec. since the last reset.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

cdx6500NMNPSpvcConnectCur 1.3.6.1.4.1.449.2.1.1.2.3.16
Permanent virtual circuit connections. The number currently in place.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cdx6500NMNPSPVCConnectMax 1.3.6.1.4.1.449.2.1.1.2.3.17
Permanent virtual circuit connections. The maximum since the last reset.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

cdx6500NMNPSbuffDataAvail 1.3.6.1.4.1.449.2.1.1.2.3.18
The number of data buffers available. Applicable to all platforms.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER  

cdx6500NMNPSbuffDataUse 1.3.6.1.4.1.449.2.1.1.2.3.19
The number of data buffers in use. Applicable to all platforms.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER  

cdx6500NMNPSbuffDataGauge 1.3.6.1.4.1.449.2.1.1.2.3.20
The maximum number of data buffers in use since last reset Applicable to all platforms.
Status: optional Access: read-only
OBJECT-TYPE    
  Gauge  

cdx6500NMNPSbuffPacketAvail 1.3.6.1.4.1.449.2.1.1.2.3.21
The number of packet buffers available. Applicable to all platforms except VG100 .
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER  

cdx6500NMNPSbuffPacketUse 1.3.6.1.4.1.449.2.1.1.2.3.22
The number of packet buffers in use. Applicable to all platforms except VG100.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER  

cdx6500NMNPSbuffPacketExhaust 1.3.6.1.4.1.449.2.1.1.2.3.23
The number of times the packet buffer pool has been exhausted since last reset. Applicable to all platforms except VG100.
Status: optional Access: read-only
OBJECT-TYPE    
  Gauge  

cdx6500NMNPSbuffMgtAvail 1.3.6.1.4.1.449.2.1.1.2.3.24
The number of management buffers available. Applicable to all platforms except VG100.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER  

cdx6500NMNPSbuffMgtUse 1.3.6.1.4.1.449.2.1.1.2.3.25
The number of management buffers in use. Applicable to all platforms except VG100.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER  

cdx6500NMNPSbuffMgtExhaust 1.3.6.1.4.1.449.2.1.1.2.3.26
The number of times the management buffer pool has been exhausted since last reset. Applicable to all platforms except VG100.
Status: optional Access: read-only
OBJECT-TYPE    
  Gauge  

cdx6500NMNPSrateCurChar 1.3.6.1.4.1.449.2.1.1.2.3.27
Node throughput, number of current chararacters/second for the node.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cdx6500NMNPSrateCurPkt 1.3.6.1.4.1.449.2.1.1.2.3.28
Node throughput, number of current packets/second for the node.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cdx6500NMNPSrateMaxChar 1.3.6.1.4.1.449.2.1.1.2.3.29
Node throughput gauge, Number of maximum characters/second for the node since last reset
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

cdx6500NMNPSrateMaxPkt 1.3.6.1.4.1.449.2.1.1.2.3.30
Node throughput gauge, Number of maximum packets/second for the node since last reset
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

cdx6500NMNPSmemEprom 1.3.6.1.4.1.449.2.1.1.2.3.31
Amount of memory available on the processor card in bytes. Applicable to 6520 platforms.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER  

cdx6500NMNPSmemDram 1.3.6.1.4.1.449.2.1.1.2.3.32
Amount of memory used for data buffers in bytes. Applicable to 6520 platforms.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER  

cdx6500NMNPSmemFlashCur 1.3.6.1.4.1.449.2.1.1.2.3.33
The size of the flash module in bytes. This refers to the currently selected bank of flash when there is an alternate bank of flash installed. Applicable to 6520 platforms.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER  

cdx6500NMNPSmemFlashAlt 1.3.6.1.4.1.449.2.1.1.2.3.34
The size of the alternate flash module in bytes. Applicable to 6520 platforms.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER  

cdx6500NMNPScpuUtil 1.3.6.1.4.1.449.2.1.1.2.3.35
Percentage of time the CPU processed traffic data (as opposed performing diagnositic tests or processing node control data) to in the last 64 seconds. Applicable to 6520 platforms.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER  

cdx6500NMNPSDisplayNumImage 1.3.6.1.4.1.449.2.1.1.2.3.36
Front panel numeric display. Applicable to 6520 platforms.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString  

cdx6500NMNPSDisplayLEDstatus 1.3.6.1.4.1.449.2.1.1.2.3.37
Front panel status LED. Applicable to 6520 platforms. newvalOff : same functionality as 'off', new enumeration added for RFC1155 compatibility.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER off(0), on(1), blinking(2), newvalOff(50), notSupported(100)  

cdx6500NMNPSDisplayLEDdiag 1.3.6.1.4.1.449.2.1.1.2.3.38
Front panel fault (or service) LED. Applicable to 6520 platforms. newvalOff : same functionality as 'off', new enumeration added for RFC1155 compatibility.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER off(0), on(1), blinking(2), newvalOff(50), notSupported(100)  

cdx6500NMNPSdefaultNode 1.3.6.1.4.1.449.2.1.1.2.3.39
A control object. Setting to value default will cause the current configuration of the entire node to change back to the default settings. CAUTION: If you implement the Default Node control, communications are disrupted and data could be lost after a boot. In addition, configuration settings are lost unless they had been saved to an external device.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  INTEGER default(1), noDefault(2)  

cdx6500NMNPSresetStatTable 1.3.6.1.4.1.449.2.1.1.2.3.40
A list of Port Statistic Reset entries.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Cdx6500NMNPSresetStatEntry

cdx6500NMNPSresetStatAll 1.3.6.1.4.1.449.2.1.1.2.3.41
A value of reset will cause statistics to be reset on all ports. A value of noReset has no effect.
Status: mandatory Access: write-only
OBJECT-TYPE    
  INTEGER reset(1), noReset(2)  

cdx6500NMNPSstatusPowerSy 1.3.6.1.4.1.449.2.1.1.2.3.42
The operational status of the power supply. This object replaces cdx6500NMNPSstatusPwrSy.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..20)  

cdx6500NMNPSresetStatEntry 1.3.6.1.4.1.449.2.1.1.2.3.40.1
Each entry contains a port number and a control to reset statistics for that port.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Cdx6500NMNPSresetStatEntry  

cdx6500NMNPSresetStatPort 1.3.6.1.4.1.449.2.1.1.2.3.40.1.1
The port number value for this object directs the statistics reset command to that port.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  INTEGER 1..54  

cdx6500NMNPSresetStatStatus 1.3.6.1.4.1.449.2.1.1.2.3.40.1.2
A value of reset will cause a port's statistics to be reset. A value of noReset has no effect.
Status: mandatory Access: write-only
OBJECT-TYPE    
  INTEGER reset(1), noReset(2)  

cdx6500NMNPSstatsTable 1.3.6.1.4.1.449.2.1.1.2.3.43
Board specific statistics. Applicable to 6500 platforms.
Status: optional Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Cdx6500NMNPSstatsEntry

cdx6500NMNPSstatsEntry 1.3.6.1.4.1.449.2.1.1.2.3.43.1
A Board statistics Table entry. Each entry contains statistics parameters for a single board. Applicable to 6500 platforms.
Status: optional Access: not-accessible
OBJECT-TYPE    
  Cdx6500NMNPSstatsEntry  

cdx6500NMNPSstatsBoard 1.3.6.1.4.1.449.2.1.1.2.3.43.1.1
Board number. Applicable to 6500 platforms.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER  

cdx6500NMNPSstatsbuffDataAvail 1.3.6.1.4.1.449.2.1.1.2.3.43.1.2
The number of data buffers available. Applicable to 6500 platforms.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER  

cdx6500NMNPSstatsbuffDataUse 1.3.6.1.4.1.449.2.1.1.2.3.43.1.3
The number of data buffers in use. Applicable to 6500 platforms.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER  

cdx6500NMNPSstatsbuffDataGauge 1.3.6.1.4.1.449.2.1.1.2.3.43.1.4
The maximum number of data buffers in use since last reset Applicable to 6500 platforms.
Status: optional Access: read-only
OBJECT-TYPE    
  Gauge  

cdx6500NMNPSstatsmemEprom 1.3.6.1.4.1.449.2.1.1.2.3.43.1.5
Amount of memory available on the processor card in bytes. Applicable to 6500 platforms.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER  

cdx6500NMNPSstatsmemDram 1.3.6.1.4.1.449.2.1.1.2.3.43.1.6
Amount of memory used for data buffers in bytes. Applicable to 6500 platforms.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER  

cdx6500NMNPSstatsmemFlash 1.3.6.1.4.1.449.2.1.1.2.3.43.1.7
The size of the flash module in bytes. This refers to the currently selected bank of flash when there is an alternate bank of flash installed. Applicable to 6500 platforms.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER  

cdx6500NMNPSstatscpuUtil 1.3.6.1.4.1.449.2.1.1.2.3.43.1.8
Percentage of time the CPU processed traffic data (as opposed performing diagnositic tests or processing node control data) to in the last 64 seconds. Applicable to 6500 platforms.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER  

cdx6500NMNPSstatsMaxcpuUtil 1.3.6.1.4.1.449.2.1.1.2.3.43.1.9
Peak CPU Utilization since last node or statistics reset. Applicable to 6500 platforms.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER  

cdx6500NMNPSstatsMaxcpuUtilTime 1.3.6.1.4.1.449.2.1.1.2.3.43.1.10
Time stamp of Peak CPU Utilization since last node or statistics reset. Applicable to 6500 platforms.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString  

cdx6500NMNPScallsInPlaceMaxTime 1.3.6.1.4.1.449.2.1.1.2.3.44
Time stamp of Max number of calls since the last reset.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

cdx6500NMNPSPVCConnectMaxTime 1.3.6.1.4.1.449.2.1.1.2.3.45
Time stamp of Max number of PVC connections since the last reset.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

cdx6500NMNPScallsPerSecMaxTime 1.3.6.1.4.1.449.2.1.1.2.3.46
Time stamp of Max number of calls/sec since the last reset.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

cdx6500NMNPSbuffDataGaugeTime 1.3.6.1.4.1.449.2.1.1.2.3.47
Time stamp of Max number of data buffers in use since the last reset. Applicable to all platforms.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString  

cdx6500NMNPSbuffPacketGauge 1.3.6.1.4.1.449.2.1.1.2.3.48
The maximum number of packet buffers in use since the last reset. Applicable to all platforms except VG100.
Status: optional Access: read-only
OBJECT-TYPE    
  Gauge  

cdx6500NMNPSbuffPacketGaugeTime 1.3.6.1.4.1.449.2.1.1.2.3.49
Time stamp of Max number of packet buffers in use since the last reset. Applicable to all platforms except VG100.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString  

cdx6500NMNPSbuffMgtGauge 1.3.6.1.4.1.449.2.1.1.2.3.50
The maximum number of management buffers in use since the last reset. Applicable to all platforms except VG100.
Status: optional Access: read-only
OBJECT-TYPE    
  Gauge  

cdx6500NMNPSbuffMgtGaugeTime 1.3.6.1.4.1.449.2.1.1.2.3.51
Time stamp of Max number of management buffers in use since the last reset. Applicable to all platforms except VG100.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString  

cdx6500NMNPSrateMaxCharTime 1.3.6.1.4.1.449.2.1.1.2.3.52
Time stamp of Max node throughput (chars/sec) since the last reset.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

cdx6500NMNPSrateMaxPktTime 1.3.6.1.4.1.449.2.1.1.2.3.53
Time stamp of Max node throughput (packets/sec) since the last reset.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

cdx6500NMNPSMaxcpuUtil 1.3.6.1.4.1.449.2.1.1.2.3.54
Peak CPU Utilization since last node or statistics reset. Applicable to 6520 platforms.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER  

cdx6500NMNPSMaxcpuUtilTime 1.3.6.1.4.1.449.2.1.1.2.3.55
Time stamp of Peak CPU Utilization since last node or statistics reset. Applicable to 6520 platforms.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString  

cdx6500NMReportTable 1.3.6.1.4.1.449.2.1.1.3.1
All of the statistics parameters relevant to the Report event log table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Cdx6500NMReportEntry

cdx6500NMReportEntry 1.3.6.1.4.1.449.2.1.1.3.1.1
A row of Report Statistics parameters.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Cdx6500NMReportEntry  

cdx6500reptIndex 1.3.6.1.4.1.449.2.1.1.3.1.1.1
Report Log Index
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  INTEGER 1..512  

cdx6500reptEvent 1.3.6.1.4.1.449.2.1.1.3.1.1.2
Report Log Alarm Text
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..152)  

cdx6500NMreptClearLog 1.3.6.1.4.1.449.2.1.1.3.2
Clears the Operator log. clearLog - Clear the Log noClearLog - Do not clear the Log.
Status: mandatory Access: write-only
OBJECT-TYPE    
  INTEGER clearLog(1), noClearLog(2)  

cdx6500NMV54Loopback 1.3.6.1.4.1.449.2.1.1.3.3
OBJECT IDENTIFIER    

cdx6500NMV54LocalLoop 1.3.6.1.4.1.449.2.1.1.3.3.1
Local loop test; The test will start when set to value 'startTest'.
Status: obsolete Access: write-only
OBJECT-TYPE    
  INTEGER startTest(1), noTest(2)  

cdx6500NMV54Loop2 1.3.6.1.4.1.449.2.1.1.3.3.2
Loopback test 2 : Loop at remote modem digital side.
Status: obsolete Access: write-only
OBJECT-TYPE    
  INTEGER startTest(1), noTest(2)  

cdx6500NMV54Loop3 1.3.6.1.4.1.449.2.1.1.3.3.3
Loopback test 3: Loop at local modem analog side.
Status: obsolete Access: write-only
OBJECT-TYPE    
  INTEGER startTest(1), noTest(2)  

cdx6500NMV54turnLoopbackOff 1.3.6.1.4.1.449.2.1.1.3.3.4
A control to turn any loopback test off
Status: obsolete Access: write-only
OBJECT-TYPE    
  INTEGER loopbackOff(1)  

cdx6500NMV54LoopbackDuration 1.3.6.1.4.1.449.2.1.1.3.3.5
Duration of loopback in seconds.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..65535  

cdx6500NMV54TestType 1.3.6.1.4.1.449.2.1.1.3.3.6
Loopback test type.
Status: obsolete Access: read-only
OBJECT-TYPE    
  INTEGER v54LocalLoop(1), v54Loop2(2), v54Loop3(3)  

cdx6500NMV54LoopbackStatus 1.3.6.1.4.1.449.2.1.1.3.3.7
Loopback Status. v54Starting - test is being prepared to start. v54Running - test in progress. v54Stopping - test is being stopped. v54Clearing - system is clearing resources used for the test. v54Stopped - test has been completed. v54AbortPortDisabled - selected port is disabled. v54AbortIsRunning - test is already running on the specified port. v54AbortPortNull - selected port is of NULL type. v54AbortEiaDisc - interface has been disconnected during the test. v54AbortCpuNotRunning - CPU is not running on the specified port. v54AbortNotSupported - specified test is not supported by the selected port. v54AbortWrongParams - specified test params are incorrect. Check port number. v54AbortWrongPort - specified port is incorrect. v54NotRun - test has not been run yet.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER v54Starting(1), v54Running(2), v54Stopping(3), v54Clearing(4), v54Stopped(5), v54AbortPortDisabled(6), v54AbortIsRunning(7), v54AbortPortNull(8), v54AbortEiaDisc(9), v54AbortCpuNotRunning(10), v54AbortNotSupported(11), v54AbortWrongParams(12), v54AbortWrongPort(13), v54NotRun(14)  

cdx6500NMV54MessagesSent 1.3.6.1.4.1.449.2.1.1.3.3.9
Number of messages sent
Status: obsolete Access: read-only
OBJECT-TYPE    
  INTEGER  

cdx6500NMV54GoodMsgsReceived 1.3.6.1.4.1.449.2.1.1.3.3.10
Number of good messages received
Status: obsolete Access: read-only
OBJECT-TYPE    
  INTEGER  

cdx6500NMV54BadMsgsReceived 1.3.6.1.4.1.449.2.1.1.3.3.11
Number of bad messages received
Status: obsolete Access: read-only
OBJECT-TYPE    
  INTEGER  

cdx6500NMV54LastPortTested 1.3.6.1.4.1.449.2.1.1.3.3.12
Last port to be put in loopback.
Status: obsolete Access: read-only
OBJECT-TYPE    
  INTEGER 1..54  

cdx6500NMV54CurrentTestPort 1.3.6.1.4.1.449.2.1.1.3.3.13
Current test port.
Status: obsolete Access: read-write
OBJECT-TYPE    
  INTEGER 1..54  

cdx6500NMV54LoopbackTest 1.3.6.1.4.1.449.2.1.1.3.3.14
Starts and stops loopback test.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER testing(1), notTesting(2)  

cdx6500NMV54LoopbackTestType 1.3.6.1.4.1.449.2.1.1.3.3.15
Loopback test type. v54LocalLoop - creates a loop on the selected port. v54Loop2 - creates a loop on the remote modem digital side. v54Loop3 - creates a loop on the local modem analog side. dsuInternal - creates a loop on the internal interface. dsuInternalExternal - creates a loop on the internal and the external interfaces.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER v54LocalLoop(1), v54Loop2(2), v54Loop3(3), dsuInternal(4), dsuInternalExternal(5)  

cdx6500NMV54LoopbackLastPortTested 1.3.6.1.4.1.449.2.1.1.3.3.16
Last port put in loopback.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..54  

cdx6500NMV54LoopbackCurrentTestPort 1.3.6.1.4.1.449.2.1.1.3.3.17
Current test port. Value zero means that no port has been specified. When test completes, this object is defaulted to zero.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..54  

cdx6500NMV54LoopbackMessagesSent 1.3.6.1.4.1.449.2.1.1.3.3.18
Number of messages sent
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

cdx6500NMV54LoopbackGoodMsgsReceived 1.3.6.1.4.1.449.2.1.1.3.3.19
Number of good messages received
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

cdx6500NMV54LoopbackBadMsgsReceived 1.3.6.1.4.1.449.2.1.1.3.3.20
Number of bad messages received
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

cdx6500NMCBootNode 1.3.6.1.4.1.449.2.1.1.4.1
Setting this object will cuase the node to perform either a cold or a warm Node boot : bootCold - perform a cold Node Boot; run diagnostic tests, reload operational software, request software download if neccessary, reload configuration and start the node. bootWarm - perform a warm Node Boot; reload configuration and start the node. newvalBootCold - same functionality as 'bootCold', new enumeration added for RFC1155 compatibility.
Status: mandatory Access: write-only
OBJECT-TYPE    
  INTEGER bootCold(0), bootWarm(1), newvalBootCold(50)  

cdx6500NMCBootTableNodeRec 1.3.6.1.4.1.449.2.1.1.4.2
Setting to bootrec will cause the running configuration to be updated using new configuration tables from CMEM.
Status: mandatory Access: write-only
OBJECT-TYPE    
  INTEGER bootrec(1)  

cdx6500DLSVDLstate 1.3.6.1.4.1.449.2.1.1.5.1
Statistic - state of the download dlStart : Setup phase. dlCall : Setup phase. dlReq : Setup phase. dlLoad : Downloading phase. dlGss : Setup phase. dlLgs : Downloading phase. dlDone : Download Complete. dlBoot : Download Complete. dlIdle : No download.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER dlStart(1), dlCall(2), dlReq(3), dlLoad(4), dlGss(8), dlLgs(16), dlDone(32), dlBoot(64), dlIdle(50)  

cdx6500DLSVPercentComplete 1.3.6.1.4.1.449.2.1.1.5.2
Statistic - amount of download that has completed.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cdx6500DLSVTimestamp 1.3.6.1.4.1.449.2.1.1.5.3
Statistic - time of last download.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

cdx6500DLSVLastServer 1.3.6.1.4.1.449.2.1.1.5.4
Statistic - Last server node to send software.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

cdx6500DLSVTransferType 1.3.6.1.4.1.449.2.1.1.5.5
Statistic - type of transfer - i.e. which bank to which bank at what throughput.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER idle(1), ramToram(2), flashToflash(3)  

cdx6500DLSVInitiateTransfer 1.3.6.1.4.1.449.2.1.1.5.6
Type of transfer - i.e. which bank to which bank at what throughput setting this initiates the flash to flash transfer.
Status: mandatory Access: write-only
OBJECT-TYPE    
  INTEGER  

cdx6500DLSVAgntSegmentSize 1.3.6.1.4.1.449.2.1.1.5.7
This is the segment size used for accounting purposes with data packets. segmentSizeDisable - segment counting disabled. segmentSize16 - 16 byte segments. segmentSize32 - 32 byte segments. segmentSize64 - 64 byte segments. segmentSize128 - 128 byte segments. segmentSize256 - 256 byte segments. segmentSize512 - 512 byte segments. segmentSize1024 - 1024 byte segments newvalSegmentSizeDisable - same as 'segmentSizeDisable', new enumeration added for RFC1155 compatibility.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER segmentSizeDisable(0), segmentSize16(4), segmentSize32(5), segmentSize64(6), segmentSize128(7), segmentSize256(8), segmentSize512(9), segmentSize1024(10), newvalSegmentSizeDisable(50)  

cdx6500DLSVAgntnmServAddress 1.3.6.1.4.1.449.2.1.1.5.8
This is the mnemonic name of the download server assigned to load this node with operational software.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..8)  

cdx6500DLSVagntloaderSubaddress 1.3.6.1.4.1.449.2.1.1.5.9
This is the subaddress of the download module in this node.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cdx6500DLSVagntdlServSubaddress 1.3.6.1.4.1.449.2.1.1.5.10
Calls with network address composed of the node address (configured in the Node record) and this subaddress will be routed to the module in this node which sends code to a remote node. No routing table entry is needed.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cdx6500PPSTallPortsTable 1.3.6.1.4.1.449.2.1.3.1.1.18
All of the statistics parameters relevant to the allPorts table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Cdx6500PPSTallPortsEntry

cdx6500PPSTallPortsEntry 1.3.6.1.4.1.449.2.1.3.1.1.18.1
A row of allPorts statistics parameters.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Cdx6500PPSTallPortsEntry  

cdx6500allportsPortNum 1.3.6.1.4.1.449.2.1.3.1.1.18.1.1
Number of the port
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..54  

cdx6500allportsPortType 1.3.6.1.4.1.449.2.1.3.1.1.18.1.2
Type of port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER null(1), pad(2), x25(3), mux(4), mx25(9), bsc2780(11), bsc3270(12), vip(13), pos(14), sdlc(15), ncrbsc(16), fri(17), xdlc(18), bstd(19), rs366(20), ibm2260(23), vap(24), tbop(25), n270(26), tcop(27), tr(28), eth(29), alc(31), sl(32), fra(33), t3pos(34), atpad(35), tnpp(36), slip(37), hub(39), bri(40), x32pcm(41), ppp(42), voice(43), t1(44), e1(45), tdlc(48), ptype3201(50), gsc(51), spp(52), t1e1(54), t3e3(55), atm(56)  

cdx6500allportsPortStatus 1.3.6.1.4.1.449.2.1.3.1.1.18.1.3
Status of the port. disabled - Port is disabled. enabled - Port is enabled. busyOut - Port is busyOuted. up - Port is up. down - Port is down. newvalDisabled - same functionality as 'disabled', new enumeration added for RFC1155 compatibility.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER disabled(0), enabled(1), busyOut(2), up(3), down(4), newvalDisabled(50)  

cdx6500allportsPortState 1.3.6.1.4.1.449.2.1.3.1.1.18.1.4
Current Port state.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(1..25)  

cdx6500allportsPortSpeed 1.3.6.1.4.1.449.2.1.3.1.1.18.1.5
This is the speed of the port when Clock=Int; this is detected clock speed if Clock=Ext. If Port Speed is 0, Clock=Ext then clocking is not being received from attached device.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cdx6500allportsUtilizationIn 1.3.6.1.4.1.449.2.1.3.1.1.18.1.6
Percentage of port bandwidth in use.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cdx6500allportsUtilizationOut 1.3.6.1.4.1.449.2.1.3.1.1.18.1.7
Percentage of port bandwidth in use.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cdx6500allportsCharInTot 1.3.6.1.4.1.449.2.1.3.1.1.18.1.8
Number of characters received by the port since the last node, port or statistics reset.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

cdx6500allportsCharOutTot 1.3.6.1.4.1.449.2.1.3.1.1.18.1.9
Number of characters sent by the port since the last node, port or statistics reset.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

cdx6500allportsPktInTot 1.3.6.1.4.1.449.2.1.3.1.1.18.1.10
Number of packets received by the port since the last node, port or statistics reset.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

cdx6500allportsPktOutTot 1.3.6.1.4.1.449.2.1.3.1.1.18.1.11
Number of packets sent by the port since the last node, port or statistics reset.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

cdx6500allportsFrameInTot 1.3.6.1.4.1.449.2.1.3.1.1.18.1.12
Number of frames received by the port since the last node, port or statistics reset.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

cdx6500allportsFrameOutTot 1.3.6.1.4.1.449.2.1.3.1.1.18.1.13
Number of frames sent by the port since the last node, port or statistics reset.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

cdx6500allportsPktsQueued 1.3.6.1.4.1.449.2.1.3.1.1.18.1.14
Number of packets currently queued.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cdx6500allportsCharsInPerSec 1.3.6.1.4.1.449.2.1.3.1.1.18.1.15
Summary of the characters being received over the port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cdx6500allportsCharsOutPerSec 1.3.6.1.4.1.449.2.1.3.1.1.18.1.16
Summary of the characters being sent over the port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cdx6500allportsPktsInPerSec 1.3.6.1.4.1.449.2.1.3.1.1.18.1.17
Summary of the packets being received over the port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cdx6500allportsPktsOutPerSec 1.3.6.1.4.1.449.2.1.3.1.1.18.1.18
Summary of the packets being sent over the port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cdx6500allportsFramesInPerSec 1.3.6.1.4.1.449.2.1.3.1.1.18.1.19
Summary of the frames being received over the port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cdx6500allportsFramesOutPerSec 1.3.6.1.4.1.449.2.1.3.1.1.18.1.20
Summary of the frames being sent over the port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cdx6500allportsOverrunErrors 1.3.6.1.4.1.449.2.1.3.1.1.18.1.21
Number of Overrun errors since the last node or statistics reset. Overrun Errors: Received data was lost because it could not be processed by the CPU.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter16  

cdx6500allportsUnderrunErrors 1.3.6.1.4.1.449.2.1.3.1.1.18.1.22
Number of Underrun errors since the last node or statistics reset. UnderrunErrors: Transmission of a frame could not be completed because all the data had not been sent to port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter16  

cdx6500allportsCRCErrors 1.3.6.1.4.1.449.2.1.3.1.1.18.1.23
Number of CRC errors since the last node or statistics reset. CRC Errors: Cyclical Redundancy failure because of noise on the line.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter16  

cdx6500allportsParityErrors 1.3.6.1.4.1.449.2.1.3.1.1.18.1.24
Number of Parity errors since the last reset
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter16  

cdx6500allportsFramingErrors 1.3.6.1.4.1.449.2.1.3.1.1.18.1.25
Number of Framing errors since the last reset.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter16  

cdx6500allportsBootPort 1.3.6.1.4.1.449.2.1.3.1.1.18.1.26
Boots the specified Port. bootPort - Boot the Port.
Status: mandatory Access: write-only
OBJECT-TYPE    
  INTEGER bootPort(1)  

cdx6500allportsPortControlStatus 1.3.6.1.4.1.449.2.1.3.1.1.18.1.27
Change the Port Control Status. enable - Enable the Port. disable - Disable the Port. busyout - BusyOut the Port.
Status: mandatory Access: write-only
OBJECT-TYPE    
  INTEGER enable(1), disable(2), busyout(3)  

cdx6500SPSTallStationsTable 1.3.6.1.4.1.449.2.1.3.1.3.8
All of the statistics parameters relevant to the allStations table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Cdx6500SPSTallStationsEntry

cdx6500SPSTallStationsEntry 1.3.6.1.4.1.449.2.1.3.1.3.8.1
A row of allStations statistics parameters.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Cdx6500SPSTallStationsEntry  

cdx6500allstationsPortNum 1.3.6.1.4.1.449.2.1.3.1.3.8.1.1
Number of the port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..54  

cdx6500allstationsStnNum 1.3.6.1.4.1.449.2.1.3.1.3.8.1.2
Number of the station.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cdx6500allstationsStnType 1.3.6.1.4.1.449.2.1.3.1.3.8.1.3
Type of station.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..10)  

cdx6500allstationsStnStatus 1.3.6.1.4.1.449.2.1.3.1.3.8.1.4
Status of the station. disabled - Station is disabled. enabled - Station is enabled. busyOut - Station is busyOuted. up - Station is up. down - Station is down. newvalDisabled - same functionality as 'disabled', new enumeration added for RFC1155 compatibility.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER disabled(0), enabled(1), busyOut(2), up(3), down(4), newvalDisabled(50)  

cdx6500allstationsStnState 1.3.6.1.4.1.449.2.1.3.1.3.8.1.5
Current Station state.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..15)  

cdx6500allstationsUtilizationIn 1.3.6.1.4.1.449.2.1.3.1.3.8.1.6
Percentage of station bandwidth in use.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..100  

cdx6500allstationsUtilizationOut 1.3.6.1.4.1.449.2.1.3.1.3.8.1.7
Percentage of station bandwidth in use.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..100  

cdx6500allstationsCharInTot 1.3.6.1.4.1.449.2.1.3.1.3.8.1.8
Number of characters received by the station since the last node, port, station or statistics reset.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

cdx6500allstationsCharOutTot 1.3.6.1.4.1.449.2.1.3.1.3.8.1.9
Number of characters sent by the station since the last node, port, station or statistics reset.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

cdx6500allstationsPktInTot 1.3.6.1.4.1.449.2.1.3.1.3.8.1.10
Number of packets received by the station since the last node, port, station or statistics reset.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

cdx6500allstationsPktOutTot 1.3.6.1.4.1.449.2.1.3.1.3.8.1.11
Number of packets sent by the port since the last node, port, station or statistics reset.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

cdx6500allstationsFrameInTot 1.3.6.1.4.1.449.2.1.3.1.3.8.1.12
Number of frames received by the port since the last node, port, station or statistics reset.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

cdx6500allstationsFrameOutTot 1.3.6.1.4.1.449.2.1.3.1.3.8.1.13
Number of frames sent by the port since the last node, port, station or statistics reset.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

cdx6500allstationsPktsQueued 1.3.6.1.4.1.449.2.1.3.1.3.8.1.14
Number of packets currently queued.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cdx6500allstationsCharsInPerSec 1.3.6.1.4.1.449.2.1.3.1.3.8.1.15
Summary of the characters being received over the station.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cdx6500allstationsCharsOutPerSec 1.3.6.1.4.1.449.2.1.3.1.3.8.1.16
Summary of the characters being sent over the station.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cdx6500allstationsPktsInPerSec 1.3.6.1.4.1.449.2.1.3.1.3.8.1.17
Summary of the packets being received over the station.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cdx6500allstationsPktsOutPerSec 1.3.6.1.4.1.449.2.1.3.1.3.8.1.18
Summary of the packets being sent over the station.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cdx6500allstationsFramesInPerSec 1.3.6.1.4.1.449.2.1.3.1.3.8.1.19
Summary of the frames being received over the station.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cdx6500allstationsFramesOutPerSec 1.3.6.1.4.1.449.2.1.3.1.3.8.1.20
Summary of the frames being sent over the station.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cdx6500allstationsBootStation 1.3.6.1.4.1.449.2.1.3.1.3.8.1.21
Boots the specified station. bootStn - Boot Station noBootStn - Do not boot Station.
Status: mandatory Access: write-only
OBJECT-TYPE    
  INTEGER bootStn(1), noBootStn(2)  

cdx6500allstationsDisableStation 1.3.6.1.4.1.449.2.1.3.1.3.8.1.22
Disables the specified station. disableStn - Disable Station. noDisableStn - Do not disable Station.
Status: mandatory Access: write-only
OBJECT-TYPE    
  INTEGER disableStn(1), noDisableStn(2)  

cdx6500allstationsEnableStation 1.3.6.1.4.1.449.2.1.3.1.3.8.1.23
Enables the specified station. enableStn - Enable Station. noEnableStn - Not not enable Station.
Status: mandatory Access: write-only
OBJECT-TYPE    
  INTEGER enableStn(1), noEnableStn(2)  

cdx6500allstationsBusyOutStation 1.3.6.1.4.1.449.2.1.3.1.3.8.1.24
Busy out the specified station. busyoutStn - Busyout Station. noBusyoutStn - Do not busyout Station.
Status: mandatory Access: write-only
OBJECT-TYPE    
  INTEGER busyoutStn(1), noBusyoutStn(2)  

cdx6500GCTRouteSelectionTable 1.3.6.1.4.1.449.2.1.2.2.1
A list of Configuration Parameters that select the links over which calls are routed.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Cdx6500GCTRouteSelectionEntry

cdx6500GCTRouteSelectionEntry 1.3.6.1.4.1.449.2.1.2.2.1.1
Each entry contains a list of parameters that makeup the Route Selection Table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Cdx6500GCTRouteSelectionEntry  

cdx6500RoutSVCEntryNumber 1.3.6.1.4.1.449.2.1.2.2.1.1.1
This is not a configurable parameter. This identifies the particular Route Selection Table entry being configured by the other parameters in the record.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..128  

cdx6500RoutSVCAddress 1.3.6.1.4.1.449.2.1.2.2.1.1.2
This is a non-supported object. It has been replaced by cdx6500RoutSVCAddress1.
Status: deprecated Access: read-only
OBJECT-TYPE    
  INTEGER  

cdx6500RoutSVCDestination1 1.3.6.1.4.1.449.2.1.2.2.1.1.3
This specifies the network address to which calls are routed. For example: BCST route calls to the broadcast module. BSC2780-4 route calls to BSC2780 port 4. BSC3270-9 route calls to BSC3270 port 9. MX25-2s3 route calls to MX25 port 2, station 3. PAD-5 route calls to PAD port 5. P54s9 route calls to port 54, station 9. SDLC-4s5 route calls to SDLC port 4, station 5. X25-1 route calls to X25 port 1. BOSTON route backup calls to BOSTON resource.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString  

cdx6500RoutSVCPriority1 1.3.6.1.4.1.449.2.1.2.2.1.1.4
This specifies the priority for call forwarding to ports within the Route Selection Table. Call forwarding is determined by a combination of priority and load conditions. 0 - backup port. 1 to 15 - 1 is the highest priority and 15, the lowest.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..15  

cdx6500RoutSVCDestination2 1.3.6.1.4.1.449.2.1.2.2.1.1.5
This specifies the network address to which calls are routed. For example: BCST route calls to the broadcast module. BSC2780-4 route calls to BSC2780 port 4. BSC3270-9 route calls to BSC3270 port 9. MX25-2s3 route calls to MX25 port 2, station 3. PAD-5 route calls to PAD port 5. P54s9 route calls to port 54, station 9. SDLC-4s5 route calls to SDLC port 4, station 5. X25-1 route calls to X25 port 1. BOSTON route backup calls to BOSTON resource.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString  

cdx6500RoutSVCPriority2 1.3.6.1.4.1.449.2.1.2.2.1.1.6
This specifies the priority for call forwarding to ports within the Route Selection Table. Call forwarding is determined by a combination of priority and load conditions. 0 - backup port. 1 to 15 - 1 is the highest priority and 15, the lowest.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..15  

cdx6500RoutSVCDestination3 1.3.6.1.4.1.449.2.1.2.2.1.1.7
This specifies the network address to which calls are routed. For example: BCST route calls to the broadcast module. BSC2780-4 route calls to BSC2780 port 4. BSC3270-9 route calls to BSC3270 port 9. MX25-2s3 route calls to MX25 port 2, station 3. PAD-5 route calls to PAD port 5. P54s9 route calls to port 54, station 9. SDLC-4s5 route calls to SDLC port 4, station 5. X25-1 route calls to X25 port 1. BOSTON route backup calls to BOSTON resource.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString  

cdx6500RoutSVCPriority3 1.3.6.1.4.1.449.2.1.2.2.1.1.8
This specifies the priority for call forwarding to ports within the Route Selection Table. Call forwarding is determined by a combination of priority and load conditions. 0 - backup port. 1 to 15 - 1 is the highest priority and 15, the lowest.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..15  

cdx6500RoutSVCDestination4 1.3.6.1.4.1.449.2.1.2.2.1.1.9
This specifies the network address to which calls are routed. For example: BCST route calls to the broadcast module. BSC2780-4 route calls to BSC2780 port 4. BSC3270-9 route calls to BSC3270 port 9. MX25-2s3 route calls to MX25 port 2, station 3. PAD-5 route calls to PAD port 5. P54s9 route calls to port 54, station 9. SDLC-4s5 route calls to SDLC port 4, station 5. X25-1 route calls to X25 port 1. BOSTON route backup calls to BOSTON resource.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString  

cdx6500RoutSVCPriority4 1.3.6.1.4.1.449.2.1.2.2.1.1.10
This specifies the priority for call forwarding to ports within the Route Selection Table. Call forwarding is determined by a combination of priority and load conditions. 0 - backup port. 1 to 15 - 1 is the highest priority and 15, the lowest.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..15  

cdx6500RoutSVCDestination5 1.3.6.1.4.1.449.2.1.2.2.1.1.11
This specifies the network address to which calls are routed. For example: BCST route calls to the broadcast module. BSC2780-4 route calls to BSC2780 port 4. BSC3270-9 route calls to BSC3270 port 9. MX25-2s3 route calls to MX25 port 2, station 3. PAD-5 route calls to PAD port 5. P54s9 route calls to port 54, station 9. SDLC-4s5 route calls to SDLC port 4, station 5. X25-1 route calls to X25 port 1. BOSTON route backup calls to BOSTON resource.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString  

cdx6500RoutSVCPriority5 1.3.6.1.4.1.449.2.1.2.2.1.1.12
This specifies the priority for call forwarding to ports within the Route Selection Table. Call forwarding is determined by a combination of priority and load conditions. 0 - backup port. 1 to 15 - 1 is the highest priority and 15, the lowest.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..15  

cdx6500RoutSVCDestination6 1.3.6.1.4.1.449.2.1.2.2.1.1.13
This specifies the network address to which calls are routed. For example: BCST route calls to the broadcast module. BSC2780-4 route calls to BSC2780 port 4. BSC3270-9 route calls to BSC3270 port 9. MX25-2s3 route calls to MX25 port 2, station 3. PAD-5 route calls to PAD port 5. P54s9 route calls to port 54, station 9. SDLC-4s5 route calls to SDLC port 4, station 5. X25-1 route calls to X25 port 1. BOSTON route backup calls to BOSTON resource.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString  

cdx6500RoutSVCPriority6 1.3.6.1.4.1.449.2.1.2.2.1.1.14
This specifies the priority for call forwarding to ports within the Route Selection Table. Call forwarding is determined by a combination of priority and load conditions. 0 - backup port. 1 to 15 - 1 is the highest priority and 15, the lowest.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..15  

cdx6500RoutSVCDestination7 1.3.6.1.4.1.449.2.1.2.2.1.1.15
This specifies the network address to which calls are routed. For example: BCST route calls to the broadcast module. BSC2780-4 route calls to BSC2780 port 4. BSC3270-9 route calls to BSC3270 port 9. MX25-2s3 route calls to MX25 port 2, station 3. PAD-5 route calls to PAD port 5. P54s9 route calls to port 54, station 9. SDLC-4s5 route calls to SDLC port 4, station 5. X25-1 route calls to X25 port 1. BOSTON route backup calls to BOSTON resource.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString  

cdx6500RoutSVCPriority7 1.3.6.1.4.1.449.2.1.2.2.1.1.16
This specifies the priority for call forwarding to ports within the Route Selection Table. Call forwarding is determined by a combination of priority and load conditions. 0 - backup port. 1 to 15 - 1 is the highest priority and 15, the lowest.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..15  

cdx6500RoutSVCDestination8 1.3.6.1.4.1.449.2.1.2.2.1.1.17
This specifies the network address to which calls are routed. For example: BCST route calls to the broadcast module. BSC2780-4 route calls to BSC2780 port 4. BSC3270-9 route calls to BSC3270 port 9. MX25-2s3 route calls to MX25 port 2, station 3. PAD-5 route calls to PAD port 5. P54s9 route calls to port 54, station 9. SDLC-4s5 route calls to SDLC port 4, station 5. X25-1 route calls to X25 port 1. BOSTON route backup calls to BOSTON resource.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString  

cdx6500RoutSVCPriority8 1.3.6.1.4.1.449.2.1.2.2.1.1.18
This specifies the priority for call forwarding to ports within the Route Selection Table. Call forwarding is determined by a combination of priority and load conditions. 0 - backup port. 1 to 15 - 1 is the highest priority and 15, the lowest.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..15  

cdx6500RoutSVCAddress1 1.3.6.1.4.1.449.2.1.2.2.1.1.19
Network address for calls routed beyond this node. A route selection entry is not needed for calls destined within this node: PAD port or node resource (for example, control port) calls. The wild card(match anything) character is * and can also be part of the entry. When set to (blank), this parameter is ignored.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString  

cdx6500GCTPVCSetupTable 1.3.6.1.4.1.449.2.1.2.2.5
A list of Configuration Parameters for PVCs.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Cdx6500GCTPVCSetupEntry

cdx6500GCTPVCSetupEntry 1.3.6.1.4.1.449.2.1.2.2.5.1
Each entry contains a PVC source and PVC destination.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Cdx6500GCTPVCSetupEntry  

cdx6500PVCSetupEntryNumber 1.3.6.1.4.1.449.2.1.2.2.5.1.1
This is not a configurable parameter. This identifies the particular PVC Table entry being configured by the other parameters in the record.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..256  

cdx6500PVCSetupSource 1.3.6.1.4.1.449.2.1.2.2.5.1.2
This is the PVC source channel identifier. Entries are not case sensitive. For example: BCST route calls to the broadcast module. MX25-2s3(2) route calls to MX25 port 2, station 3, channel 2. PAD-5 route calls to PAD port 5. P54S9(22) route calls to port 54, station 9, channel 22. SDLC-4s5 route calls to SDLC port 4, station 5. X25-1(5) route calls to X25 port 1, channel 5.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString  

cdx6500PVCSetupDestination 1.3.6.1.4.1.449.2.1.2.2.5.1.3
This is the PVC destination channel identifier. Entries are not case sensitive. For example: BCST route calls to the broadcast module. MX25-2s3(2) route calls to MX25 port 2, station 3, channel 2. PAD-5 route calls to PAD port 5. P54S9(22) route calls to port 54, station 9, channel 22. SDLC-4s5 route calls to SDLC port 4, station 5. X25-1(5) route calls to X25 port 1, channel 5.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString  

cdx6500CfgMnemonicTable 1.3.6.1.4.1.449.2.1.2.2.6
All of the configuration parameters relevant to the Mnemonic table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Cdx6500CfgMnemonicEntry

cdx6500CfgMnemonicEntry 1.3.6.1.4.1.449.2.1.2.2.6.1
A row of mnemonic configuration parameters.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Cdx6500CfgMnemonicEntry  

cdx6500mnemEntryNum 1.3.6.1.4.1.449.2.1.2.2.6.1.1
This is not a configuration parameter. Instead, it identifies the particular Mnemonic Table entry being configured by the other parameters in the record. NOTE: You can have up to 256 entries for the 6507Plus and 6525Plus, but only 64 entries for the 6505Plus.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..256  

cdx6500mnemName 1.3.6.1.4.1.449.2.1.2.2.6.1.2
This is an mnemonic name available to PAD port users for abbreviated calling or autocalling. The following parameter will specify call details. The mnemonic CTP is reserved and specifies a call to the control port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..8)  

cdx6500mnemx28Cmd 1.3.6.1.4.1.449.2.1.2.2.6.1.3
This specifies call details for the mnemonic configured in the previous parameter. Use the format of an X.28 call command, but leave out the command specifier (the c or call).
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..64)  

cdx6500GCTNUIPasswordTable 1.3.6.1.4.1.449.2.1.2.2.7
A list of NUI/Password configuration entries.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Cdx6500GCTNUIPasswordEntry

cdx6500GCTNUIPasswordEntry 1.3.6.1.4.1.449.2.1.2.2.7.1
The Network User Identification (NUI)/Password Table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Cdx6500GCTNUIPasswordEntry  

cdx6500NUITEntryNumber 1.3.6.1.4.1.449.2.1.2.2.7.1.1
This is not a configurable parameter. Instead, it identifies the particular NUI/Password Table entry being configured by the other parameters in the record.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..400  

cdx6500NUITAcctName 1.3.6.1.4.1.449.2.1.2.2.7.1.2
This is the account name for billing records.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..8)  

cdx6500NUITPasswd 1.3.6.1.4.1.449.2.1.2.2.7.1.3
This is the password for the account name.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..8)  

cdx6500NUITPADPromptNum 1.3.6.1.4.1.449.2.1.2.2.7.1.4
This parameter specifies which entry in the PAD Prompt Table is used as a PAD prompt after the user has entered a valid password. Use 0 for standard asterisk prompt.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..8  

cdx6500GCTSoftwareKeyTable 1.3.6.1.4.1.449.2.1.2.2.12
A table of Software Key configuration entries.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Cdx6500GCTSoftwareKeyEntry

cdx6500GCTSoftwareKeyEntry 1.3.6.1.4.1.449.2.1.2.2.12.1
The Software Key for a specific optional software product code.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Cdx6500GCTSoftwareKeyEntry  

cdx6500CSISSoftKeyEntryNumber 1.3.6.1.4.1.449.2.1.2.2.12.1.1
This is not a configurable parameter. It is the reference number for the individual software option that is being enabled. You must configure a separate entry for each software option enabled at the node. A node may have up to 20 options enabled at one time.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..20  

cdx6500CSISSoftKeyValue 1.3.6.1.4.1.449.2.1.2.2.12.1.2
This is a software key supplied by Codex Corporation for this node.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..20)  

cdx6500OSTCSISOptionStatTable 1.3.6.1.4.1.449.2.1.3.2.5
A table describing the Software Options that have been purchased and enabled for this node.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Cdx6500OSTCSISOptionStatEntry

cdx6500OSTCSISOptionStatEntry 1.3.6.1.4.1.449.2.1.3.2.5.1
A list of objects describing a single Software Option.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Cdx6500OSTCSISOptionStatEntry  

cdx6500CSISOptionNumber 1.3.6.1.4.1.449.2.1.3.2.5.1.1
Table index, which is code for the software option. Following are the various software options and their codes. 1 - MX25 2 - SDLC 3 - BSC3270 4 - BSC2780 5 - VIP 6 - VIDEOTEX 7 - Data/Connection Protect 8 - INL backup 9 - FR DTE Interface 10 - 6600 ETM 11 - NCRBSC 12 - TRANSPARENT POLLED ASYNC 13 - INTERNAL DSD 14 - 801 AUTODIALER 15 - BSTD 16 - FLASH Enable 17 - NCCP Pad 18 - TBOP 19 - Source Routing Bridge 22 - IBM2260 23 - XDLC 24 - Transparent Bridge 25 - Local Termination 26 - SR/TB Bridge 29 - IP Routing 31 - FR DCE Interface 32 - 6520 Model ID RN 33 - 6520 Model ID SN 34 - 6520 Model ID BN 40 - TCOP 42 - FrameRelay LLC Conversion 43 - IP stack on CPU+ 44 - TNPP-PAD Enable 45 - Token Ring LLC Conversion 46 - Ethernet LLC Conversion 50 - Dial-Out Routing Manager 51 - Dial-Out Routing Agent 52 - Chinapac Billing Feature 53 - Chinapac NUIC Interface 54 - X32 Port 55 - Chinapac NUI Concentrator.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..55  

cdx6500CSISMaxAllowed 1.3.6.1.4.1.449.2.1.3.2.5.1.2
Number of ports that this option can support. Options can be purchased to support different numbers of ports. Value of 65535 indicates no limit.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..65535  

cdx6500CSISNumUsed 1.3.6.1.4.1.449.2.1.3.2.5.1.3
The number of ports actually being used with this option.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..54  

cdx6500CSISOptionAuth 1.3.6.1.4.1.449.2.1.3.2.5.1.4
unauthorized - an attempt was made to use an option that has not been purchased or enabled. authorized - all attempts to use the option were authorized.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unauthorized(1), authorized(2)  

cdx6500OSTCSISPortUsageTable 1.3.6.1.4.1.449.2.1.3.2.6
A table providing statistics on unauthorized port usage.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Cdx6500OSTCSISPortUsageEntry

cdx6500OSTCSISPortUsageEntry 1.3.6.1.4.1.449.2.1.3.2.6.1
A list of authorization statistics for a single port.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Cdx6500OSTCSISPortUsageEntry  

cdx6500CSISPortNumber 1.3.6.1.4.1.449.2.1.3.2.6.1.1
The port's number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..54  

cdx6500CSISPortAuth 1.3.6.1.4.1.449.2.1.3.2.6.1.2
unauthorized - an attempt was made to use this port to exceed an option port limit. authorized - the port was not used in an unauthorized fashion.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unauthorized(1), authorized(2)  

cdx6500StatSVCTable 1.3.6.1.4.1.449.2.1.3.4.1
A table of currently active switched virtual circuits (SVC). The table is dynamic i.e. changing as queries are being performed on the table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Cdx6500StatSVCEntry

cdx6500StatSVCEntry 1.3.6.1.4.1.449.2.1.3.4.1.1
A list of objects describing a single SVC.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Cdx6500StatSVCEntry  

cdx6500StatSVCIndex 1.3.6.1.4.1.449.2.1.3.4.1.1.1
It is position in the list of SVC's.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..65535  

cdx6500StatSVCCallingChannel 1.3.6.1.4.1.449.2.1.3.4.1.1.2
Calling channel of SVC.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..17)  

cdx6500StatSVCCalledChannel 1.3.6.1.4.1.449.2.1.3.4.1.1.3
Called channel of SVC.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..17)  

cdx6500StatSVCReverseCharge 1.3.6.1.4.1.449.2.1.3.4.1.1.4
Reverse charge facility condition. refuse - Refused the condition. accept - Accepted the condition. newvalRefuse - same functionality as 'refuse', new enumeration added for RFC1155 compatibility.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER refuse(0), accept(1), newvalRefuse(50)  

cdx6500StatSVCFastSelect 1.3.6.1.4.1.449.2.1.3.4.1.1.5
Fast select facility condition. noFastSelect - Fast select facility is not selected. fastSelect - Fast select facility is selected. newvalNoFastSelect - same functionality as 'noFastSelect', new enumeration added for RFC1155 compatibility.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noFastSelect(0), fastSelect(1), newvalNoFastSelect(50)  

cdx6500StatSVCNetUserIdentification 1.3.6.1.4.1.449.2.1.3.4.1.1.6
Net user identifiaction facility condition. notRequested - Net user identifiaction facility not requested. requested - Net user identifiaction facility requested. newvalNotRequested - same functionality as 'notRequested', new enumeration added for RFC1155 compatibility.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER notRequested(0), requested(1), newvalNotRequested(50)  

cdx6500StatSVCClosedUserGroup 1.3.6.1.4.1.449.2.1.3.4.1.1.7
Closed user group facility on/off. notRequested - Closed user group facility off. requested - Closed user group facility on. newvalNotRequested - same functionality as 'notRequested', new enumeration added for RFC1155 compatibility.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER notRequested(0), requested(1), newvalNotRequested(50)  

cdx6500StatSVCConnectionUPTime 1.3.6.1.4.1.449.2.1.3.4.1.1.8
Time at which connection was up.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..21)  

cdx6500statResetAllStats 1.3.6.1.4.1.449.2.1.4.4.1
A control object that when set to reset will cause the node to reset ALL its statistics. reset - reset ALL node statistics. noReset - Do not reset the statistics.
Status: mandatory Access: write-only
OBJECT-TYPE    
  INTEGER reset(1), noReset(2)  

cdx6500ContFlashCopyImage 1.3.6.1.4.1.449.2.1.4.21.1
Copy image from current to alternate or alternate to current.
Status: mandatory Access: write-only
OBJECT-TYPE    
  INTEGER currentToalternate(1), alternateTocurrent(2), noOperation(100)  

cdx6500ContFlashCopyCmem 1.3.6.1.4.1.449.2.1.4.21.2
Copy cmem from current to alternate or alternate to current.
Status: mandatory Access: write-only
OBJECT-TYPE    
  INTEGER currentToalternate(1), alternateTocurrent(2), noOperation(100)  

cdx6500ContFlashActiveImage 1.3.6.1.4.1.449.2.1.4.21.3
Activate image in flash memory.
Status: mandatory Access: write-only
OBJECT-TYPE    
  INTEGER setcurrentImage(1), setalternateImage(2), noOperation(100)  

cdx6500ContFlashActiveCmem 1.3.6.1.4.1.449.2.1.4.21.4
Activate cmem in flash memory.
Status: mandatory Access: write-only
OBJECT-TYPE    
  INTEGER setcurrentCmem(1), setalternateCmem(2), noOperation(100)  

cdx6500ContFlashDeleteImage 1.3.6.1.4.1.449.2.1.4.21.5
Delete all images in flash memory.
Status: mandatory Access: write-only
OBJECT-TYPE    
  INTEGER deleteImage(1), noOperation(100)  

cdx6500CreatePortAndStationTable 1.3.6.1.4.1.449.2.1.2.1.9
Create Port and Station table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Cdx6500CreatePortAndStationEntry

cdx6500CreatePortAndStationEntry 1.3.6.1.4.1.449.2.1.2.1.9.1
Entry for representing Creating Port and Station Record.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Cdx6500CreatePortAndStationEntry  

cdx6500PortNumber 1.3.6.1.4.1.449.2.1.2.1.9.1.1
Port Number which is installed.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..256  

cdx6500CreatePortType 1.3.6.1.4.1.449.2.1.2.1.9.1.2
port type to be created. pad : PAD port x25 : X25 port mx25 : Multipoint X25 port sdlc : Synchronous Data Link Control Port xdlc : X25 Data Link Control Port fri : Frame Relay Interface Port tr : Token Ring Port eth : Ethernet Port fra : Frame Relay Access Port.
Status: mandatory Access: write-only
OBJECT-TYPE    
  INTEGER pad(2), x25(3), mx25(9), sdlc(15), fri(17), xdlc(18), tr(28), eth(29), fra(33)  

cdx6500CreateStation 1.3.6.1.4.1.449.2.1.2.1.9.1.3
station number to be created. The instance should be existing port number. Station Range : 1 - Max Station Number.
Status: mandatory Access: write-only
OBJECT-TYPE    
  INTEGER  

cdx6500ContT3E3Table 1.3.6.1.4.1.449.2.1.4.23
OBJECT IDENTIFIER    

cdx6500T3E3ContEntry 1.3.6.1.4.1.449.2.1.4.23.1
Each control applies to a single T3E3 port.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Cdx6500T3E3ContEntry  

t3e3ContPortNumber 1.3.6.1.4.1.449.2.1.4.23.1.1
Port number of the T3E3 port.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  INTEGER 1..65535  

t3e3ContPortControl 1.3.6.1.4.1.449.2.1.4.23.1.2
Control operations for the specified T3E3 port. boot - Boots the T3E3 port enable - Enables the T3E3 port disable - Disables the T3E3 port resetstats - Resets the T3E3 port statistics.
Status: mandatory Access: write-only
OBJECT-TYPE    
  INTEGER boot(1), enable(2), disable(3), resetstats(4)