CDD-564

File: CDD-564.mib (82280 bytes)

Imported modules

ComtechEFData SNMPv2-CONF SNMPv2-SMI
SNMPv2-TC

Imported symbols

comtechEFData OBJECT-GROUP MODULE-COMPLIANCE
NOTIFICATION-GROUP IpAddress Counter32
OBJECT-TYPE MODULE-IDENTITY NOTIFICATION-TYPE
DisplayString

Defined Types

Cdd564AccessListEntry  
SEQUENCE    
  cdd564AccessListIndex INTEGER
  cdd564AccessIPAddress IpAddress
  cdd564AccessSubnetMaskLength INTEGER

Cdd564FeaturesEntry  
SEQUENCE    
  cdd564FeatureIndex INTEGER
  cdd564HeaderCompression INTEGER

Cdd5643xDESRxKeyEntry  
SEQUENCE    
  cdd5643xDESRxKeyIndex INTEGER
  cdd5643xDESRxKey1 DisplayString
  cdd5643xDESRxKey2 DisplayString
  cdd5643xDESRxKey3 DisplayString
  cdd5643xDESRxKey4 DisplayString
  cdd5643xDESRxKey5 DisplayString
  cdd5643xDESRxKey6 DisplayString
  cdd5643xDESRxKey7 DisplayString
  cdd5643xDESRxKey8 DisplayString

Cdd564HDLCAddressEntry  
SEQUENCE    
  cdd564HDLCAddressIndex INTEGER
  cdd564HDLCAddress1 INTEGER
  cdd564HDLCAddress2 INTEGER
  cdd564HDLCAddress3 INTEGER
  cdd564HDLCAddress4 INTEGER

Cdd564RouteEntry  
SEQUENCE    
  cdd564RouteIndex INTEGER
  cdd564RouteName DisplayString
  cdd564RouteDestAddress IpAddress
  cdd564RouteDestMaskLen INTEGER
  cdd564RouteNextHopAddress IpAddress
  cdd564RouteMulticast INTEGER
  cdd564RouteInterface INTEGER
  cdd564RouteRowStatus INTEGER

Cdd564IGMPEntry  
SEQUENCE    
  cdd564IGMPIndex INTEGER
  cdd564IGMPTTL INTEGER
  cdd564IGMPClientState INTEGER
  cdd564IGMPSrc INTEGER
  cdd564IGMPGroupIPAddress IpAddress

Cdd564SatelliteRxStatsEntry  
SEQUENCE    
  cdd564RxStatsIndex INTEGER
  cdd564RxGoodFrames Counter32
  cdd564RxHeaderBytes Counter32
  cdd564RxPayloadBytes Counter32
  cdd564RxBadHDLCAddressErrors Counter32
  cdd564RxPktProcCRCErrors Counter32
  cdd564RxAbortOctetErrors Counter32
  cdd564RxOverrunErrors Counter32
  cdd564RxHDLCCRCErrors Counter32
  cdd564RxInvalidFlowIDErrors Counter32
  cdd564RxSARReassembleErrors Counter32
  cdd564RxHeaderDecompressionErrors Counter32
  cdd564RxMemoryAlignmentErrors Counter32
  cdd564RxCRCErrors Counter32

Cdd564RxEntry  
SEQUENCE    
  cdd564RxTableIndex INTEGER
  cdd564RxFEC INTEGER
  cdd564RxDemodulation INTEGER
  cdd564RxCodeRate INTEGER
  cdd564RxDataRate INTEGER
  cdd564RxFrequency INTEGER
  cdd564RxAcquisitionSweepWidth INTEGER
  cdd564RxDescrambling INTEGER
  cdd564RxBufferSize INTEGER
  cdd546RxSpectrumInversion INTEGER
  cdd564RxDataInversion INTEGER
  cdd564RxEbNoAlarmPoint INTEGER
  cdd564RxRecenterBuffer INTEGER
  cdd564RxSymbolRate INTEGER

Cdd564AlarmMaskEntry  
SEQUENCE    
  cdd564AlarmMaskIndex INTEGER
  cdd564AGCAlarmMask INTEGER
  cdd564EbNoAlarmMask INTEGER
  cdd564LNBAlarmMask INTEGER

Cdd564LNBEntry  
SEQUENCE    
  cdd564LNBIndex INTEGER
  cdd564LNBDCPower INTEGER
  cdd564LNB10MHzReference INTEGER
  cdm564LLNBLowCurrentLimit INTEGER
  cdd564LNBHighCurrentLimit INTEGER
  cdd564LNBLOFrequency INTEGER
  cdd564LNBLOMix INTEGER

Cdd564RxMonitorEntry  
SEQUENCE    
  cdd564RxMonitorIndex INTEGER
  cdd564RxAlarm INTEGER
  cdd564RxEbNo INTEGER
  cdd564RxSignalLevel INTEGER
  cdd564RxFreqOffset INTEGER
  cddRxBERMultiplier INTEGER

Cdd564LNBMonitorEntry  
SEQUENCE    
  cdd564LNBMonitorIndex INTEGER
  cdd564LNBAlarm INTEGER
  cdd564LNBCurrent INTEGER
  cdd564LNBVoltage INTEGER
  cdd564LNBTerminalRxFreq INTEGER

Cdd564StoredEventsEntry  
SEQUENCE    
  cdd564EventDemod INTEGER
  cdd564EventIndex INTEGER
  cdd564EventDescription DisplayString

Cdd564StoredStatisticsEntry  
SEQUENCE    
  cdd564StatisticDemod INTEGER
  cdd564StatisticIndex INTEGER
  cdd564StatisticDate DisplayString
  cdd564StatisticTime DisplayString
  cdd564StatisticAvgEbNo INTEGER
  cdd564StatisticMinEbNo INTEGER

Cdd564StoredStatisticsConfigEntry  
SEQUENCE    
  cdd564StoredStatisticsConfigIndex INTEGER
  cdd564StatisticsSampleInterval INTEGER

Cdd564CircuitIDEntry  
SEQUENCE    
  cdd564CircuitIDIndex INTEGER
  cdd564CircuitID DisplayString

Defined Values

cdd564 1.3.6.1.4.1.6247.25
Module for CDD-564 Satellite Demod
MODULE-IDENTITY    

cdd564Objects 1.3.6.1.4.1.6247.25.1
OBJECT IDENTIFIER    

cdd564Administration 1.3.6.1.4.1.6247.25.1.1
OBJECT IDENTIFIER    

cdd564AccessLists 1.3.6.1.4.1.6247.25.1.1.1
OBJECT IDENTIFIER    

cdd564AccessListTable 1.3.6.1.4.1.6247.25.1.1.1.1
The table for the access list.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Cdd564AccessListEntry

cdd564AccessListEntry 1.3.6.1.4.1.6247.25.1.1.1.1.1
The entry for the access list table.
Status: current Access: not-accessible
OBJECT-TYPE    
  Cdd564AccessListEntry  

cdd564AccessListIndex 1.3.6.1.4.1.6247.25.1.1.1.1.1.1
The index for the access list from 1..4.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 1..4  

cdd564AccessIPAddress 1.3.6.1.4.1.6247.25.1.1.1.1.1.2
The IP addresses that can access the unit. The value of 0.0.0.0 means not defined.
Status: current Access: read-write
OBJECT-TYPE    
  IpAddress  

cdd564AccessSubnetMaskLength 1.3.6.1.4.1.6247.25.1.1.1.1.1.3
The subnet mask length of the IP address for the access list. Subnet mask can be from 8..32. The value of 0 means not defined.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0 | 8..32  

cdd564AccessListEnforcement 1.3.6.1.4.1.6247.25.1.1.1.2
Enable or disable enforcement of the the access list. Note: Be sure that you have added the SNMP browser's/manager's IP Address to the access list before enabling access list filtering. Otherwise, the SNMP browser/manager will no longer be able to gain access to the unit.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(0), enabled(1)  

cdd564Features 1.3.6.1.4.1.6247.25.1.1.2
OBJECT IDENTIFIER    

cdd564PingReply 1.3.6.1.4.1.6247.25.1.1.2.1
Enable or disable ping reply from unit.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(0), enabled(1)  

cdd564Telnet 1.3.6.1.4.1.6247.25.1.1.2.2
Enable or disable telnet access to unit.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(0), enabled(1)  

cdd564IGMP 1.3.6.1.4.1.6247.25.1.1.2.3
Enable or disable the Internet Group Management Protocol (IGMP).
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(0), enabled(1)  

cdd564ForwardMulticasts 1.3.6.1.4.1.6247.25.1.1.2.4
Enable or disable forwarding all multicasts received from the Satellite interface to the Ethernet interface.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(0), enabled(1)  

cdd564FeaturesTable 1.3.6.1.4.1.6247.25.1.1.2.5
The table (per demodulator) of FAST Features.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Cdd564FeaturesEntry

cdd564FeaturesEntry 1.3.6.1.4.1.6247.25.1.1.2.5.1
The entry for the FAST Feature (per demod) table.
Status: current Access: not-accessible
OBJECT-TYPE    
  Cdd564FeaturesEntry  

cdd564FeatureIndex 1.3.6.1.4.1.6247.25.1.1.2.5.1.1
The index for the FAST Feature (per demod) table.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 1..4  

cdd564HeaderCompression 1.3.6.1.4.1.6247.25.1.1.2.5.1.2
Availability of header compression is based on FAST features Note: To use header compression, it must be FAST available and enabled on both the transmit and receive sides.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER unavailable(0), enabled(1), disabled(2)  

cdd564WorkingMode 1.3.6.1.4.1.6247.25.1.1.2.6
Configure the system's working mode. The CDM-IP can operate in any of these modes. 1. Router - Small Network Mode - The system functions as router and uses the route table to determine how to forward packets in a small network HDLC address mode. The HDLC packet uses a 1 byte HDLC address. The valid values are from 1 to 254 (0x1 - 0xFE). 2. Router - Small Network Mode - The system functions as router and uses the route table to determine how to forward packets in a large network HDLC address mode. The HDLC packet uses a 2- byte HDLC address. The valid values are from 1 to 32766 (0x1 - 0x7FFE). 3. Router - Point To Point Mode - The system functions as router but does not use HDLC addresses. 4. Router - Vipersat Mode - The system functions as router and is configured to work in a Vipersat network. *** IMPORTANT NOTE *** Changing Working mode requires the system to reboot. System configuration is saved before rebooting. Please make sure you are setting the correct value.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER routerSmallNetworkMode(1), routerLargeNetworkMode(2), routerPointToPointMode(3), routerVipersatMode(4)  

cdd5643xDESEncryption 1.3.6.1.4.1.6247.25.1.1.3
OBJECT IDENTIFIER    

cdd5643xDESRxKeyTable 1.3.6.1.4.1.6247.25.1.1.3.1
The table (one row per demod) for triple DES (3xDES) receive decrypt keys.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Cdd5643xDESRxKeyEntry

cdd5643xDESRxKeyEntry 1.3.6.1.4.1.6247.25.1.1.3.1.1
The entry (per demod) of the 3xDES receive decrypt key table.
Status: current Access: not-accessible
OBJECT-TYPE    
  Cdd5643xDESRxKeyEntry  

cdd5643xDESRxKeyIndex 1.3.6.1.4.1.6247.25.1.1.3.1.1.1
The index (per demod) of the 3xDES receive decrypt key table.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 1..4  

cdd5643xDESRxKey1 1.3.6.1.4.1.6247.25.1.1.3.1.1.2
The 3xDES receive decrypt key. The key length is 192 bits (24 bytes or 48 characters).
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(48)  

cdd5643xDESRxKey2 1.3.6.1.4.1.6247.25.1.1.3.1.1.3
The 3xDES receive decrypt key. The key length is 192 bits (24 bytes or 48 characters).
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(48)  

cdd5643xDESRxKey3 1.3.6.1.4.1.6247.25.1.1.3.1.1.4
The 3xDES receive decrypt key. The key length is 192 bits (24 bytes or 48 characters).
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(48)  

cdd5643xDESRxKey4 1.3.6.1.4.1.6247.25.1.1.3.1.1.5
The 3xDES receive decrypt key. The key length is 192 bits (24 bytes or 48 characters).
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(48)  

cdd5643xDESRxKey5 1.3.6.1.4.1.6247.25.1.1.3.1.1.6
The 3xDES receive decrypt key. The key length is 192 bits (24 bytes or 48 characters).
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(48)  

cdd5643xDESRxKey6 1.3.6.1.4.1.6247.25.1.1.3.1.1.7
The 3xDES receive decrypt key. The key length is 192 bits (24 bytes or 48 characters).
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(48)  

cdd5643xDESRxKey7 1.3.6.1.4.1.6247.25.1.1.3.1.1.8
The 3xDES receive decrypt key. The key length is 192 bits (24 bytes or 48 characters).
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(48)  

cdd5643xDESRxKey8 1.3.6.1.4.1.6247.25.1.1.3.1.1.9
The 3xDES receive decrypt key. The key length is 192 bits (24 bytes or 48 characters).
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(48)  

cdd564SMTP 1.3.6.1.4.1.6247.25.1.1.4
OBJECT IDENTIFIER    

cdd564SMTPServerIPAddress 1.3.6.1.4.1.6247.25.1.1.4.1
The IP address of the SMTP server for sending problem reports. This IP adderess should correspond to a local Mail server.
Status: current Access: read-write
OBJECT-TYPE    
  IpAddress  

cdd564SMTPDomain 1.3.6.1.4.1.6247.25.1.1.4.2
The SMTP Domain for sending problem reports. This value should be comtechefdata.com.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

cdd564SMTPUserName 1.3.6.1.4.1.6247.25.1.1.4.3
The user name for sending problem reports. This value should be cdmipsupport.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

cdd564SNMP 1.3.6.1.4.1.6247.25.1.1.5
OBJECT IDENTIFIER    

cdd564SNMPTrapDestinationIPAddress 1.3.6.1.4.1.6247.25.1.1.5.1
The IP address were SNMP notifications (traps) are to be sent. This IP address should correspond to a SNMP manager or browser.
Status: current Access: read-write
OBJECT-TYPE    
  IpAddress  

cdd564SNMPTrapCommunity 1.3.6.1.4.1.6247.25.1.1.5.2
The community that will be included in SNMP notifications (traps) that are sent from unit.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

cdd564SNMPTrapVersion 1.3.6.1.4.1.6247.25.1.1.5.3
The SNMP version that will be used when sending traps from the unit. SNMPv1 will send V1 traps. SNMPv2 will send V2 notifications.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER snmpV1(1), snmpV2(2)  

cdd564SNMPAuthenticationFailureCommunity 1.3.6.1.4.1.6247.25.1.1.5.4
The community that did not match valid SNMP Read or Write community. Note: This is ONLY used in the Authentication Failure trap.
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

cdd564SNMPAuthenticationFailureIPAddress 1.3.6.1.4.1.6247.25.1.1.5.5
The IP address that did not send a valid SNMP Read or Write community. Note: This is ONLY used in the Authentication Failure trap.
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  IpAddress  

cdd564SNMPTrapDestinationIPAddress2 1.3.6.1.4.1.6247.25.1.1.5.6
The secondary IP address were SNMP notifications (traps) are to be sent. This IP address should correspond to a secondary SNMP manager or browser.
Status: current Access: read-write
OBJECT-TYPE    
  IpAddress  

cdd564Interfaces 1.3.6.1.4.1.6247.25.1.2
OBJECT IDENTIFIER    

cdd564EthernetInterface 1.3.6.1.4.1.6247.25.1.2.1
OBJECT IDENTIFIER    

cdd564MACAddress 1.3.6.1.4.1.6247.25.1.2.1.1
The MAC address assigned to the Ethernet interface.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

cdd564EthernetSpeed 1.3.6.1.4.1.6247.25.1.2.1.2
The speed of the Ethernet interface.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER auto(1), halfDuplex10M(2), halfDuplex100M(3), fullDuplex10M(4), fullDuplex100M(5)  

cdd564IPAddress 1.3.6.1.4.1.6247.25.1.2.1.3
The IP address assigned to the Ethernet interface.
Status: current Access: read-write
OBJECT-TYPE    
  IpAddress  

cdd564SubnetMaskLen 1.3.6.1.4.1.6247.25.1.2.1.4
The subnet mask length of the IP address.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 8..30  

cdd564DemodulatorInterfaces 1.3.6.1.4.1.6247.25.1.2.2
OBJECT IDENTIFIER    

cdd564HDLCAddressMode 1.3.6.1.4.1.6247.25.1.2.2.2
The size of HDLC address used for sending packets over satellite interface can range from 0 - 2 bytes. The satellite interface will operate in one of the following modes: 1.Small Network mode - The packet uses a 1 byte HDLC address. The valid values are from 1 to 254 (0x1 - 0xFE). 2.Large Network mode - The packet uses a 2 byte HDLC address. The valid values are from 1 to 32766 (0x1 - 0x7FFE). 3. Point To Point mode - The packet does not use a HDLC address. An HDLC address cannot have 0x00 or 0xFF in least Significant Byte. i.e., 0x400 or 0x6ff or 0x11ff are NOT valid HDLC addresses.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER smallNetworkMode(1), largeNetworkMode(2), pointToPointMode(3)  

cdd564HDLCAddressTable 1.3.6.1.4.1.6247.25.1.2.2.3
The table for the Demodulator HDLC Addresses.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Cdd564HDLCAddressEntry

cdd564HDLCAddressEntry 1.3.6.1.4.1.6247.25.1.2.2.3.1
The entry of the HDLC Address table.
Status: current Access: not-accessible
OBJECT-TYPE    
  Cdd564HDLCAddressEntry  

cdd564HDLCAddressIndex 1.3.6.1.4.1.6247.25.1.2.2.3.1.1
The Demod number corresponding to 1 of 4 demodulators.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 1..4  

cdd564HDLCAddress1 1.3.6.1.4.1.6247.25.1.2.2.3.1.3
The HDLC address #1 for the satellite interface. The valid values are: 1. Small network, 1 to 254 (0x1 - 0xFE). 2. Large network, 1 to 32766 (0x1 - 0x0x7FFE). 3. Point to point, not used. 4. EasyConnect, not used. HDLC address can not have 0x00 or 0xFF in least significant byte, i.e., 0x400 or 0x6ff or 0x11ff are NOT valid HDLC addresses. Deletion: To delete the HDLC address, set it to zero.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0 | 1..32766  

cdd564HDLCAddress2 1.3.6.1.4.1.6247.25.1.2.2.3.1.4
The HDLC address #2 for the satellite interface. The valid values are: 1. Small network, 1 to 254 (0x1 - 0xFE). 2. Large network, 1 to 32766 (0x1 - 0x0x7FFE). 3. Point to point, not used. 4. EasyConnect, not used. HDLC address can not have 0x00 or 0xFF in least significant byte, i.e., 0x400 or 0x6ff or 0x11ff are NOT valid HDLC addresses. Deletion: To delete the HDLC address, set it to zero.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0 | 1..32766  

cdd564HDLCAddress3 1.3.6.1.4.1.6247.25.1.2.2.3.1.5
The HDLC address #3 for the satellite interface. The valid values are: 1. Small network, 1 to 254 (0x1 - 0xFE). 2. Large network, 1 to 32766 (0x1 - 0x0x7FFE). 3. Point to point, not used. 4. EasyConnect, not used. HDLC address can not have 0x00 or 0xFF in least significant byte, i.e., 0x400 or 0x6ff or 0x11ff are NOT valid HDLC addresses. Deletion: To delete the HDLC address, set it to zero.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0 | 1..32766  

cdd564HDLCAddress4 1.3.6.1.4.1.6247.25.1.2.2.3.1.6
The HDLC address #4 for the satellite interface. The valid values are: 1. Small network, 1 to 254 (0x1 - 0xFE). 2. Large network, 1 to 32766 (0x1 - 0x0x7FFE). 3. Point to point, not used. 4. EasyConnect, not used. HDLC address can not have 0x00 or 0xFF in least significant byte, i.e., 0x400 or 0x6ff or 0x11ff are NOT valid HDLC addresses. Deletion: To delete the HDLC address, set it to zero.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0 | 1..32766  

cdd564Routes 1.3.6.1.4.1.6247.25.1.3
OBJECT IDENTIFIER    

cdd564RouteTable 1.3.6.1.4.1.6247.25.1.3.1
The route table used in Router mode.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Cdd564RouteEntry

cdd564RouteEntry 1.3.6.1.4.1.6247.25.1.3.1.1
The entry for the the route table.
Status: current Access: not-accessible
OBJECT-TYPE    
  Cdd564RouteEntry  

cdd564RouteIndex 1.3.6.1.4.1.6247.25.1.3.1.1.1
The index for the route table.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 1..1024  

cdd564RouteName 1.3.6.1.4.1.6247.25.1.3.1.1.2
The name of the route. All routes must be named.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

cdd564RouteDestAddress 1.3.6.1.4.1.6247.25.1.3.1.1.3
The destination IP address for the route.
Status: current Access: read-write
OBJECT-TYPE    
  IpAddress  

cdd564RouteDestMaskLen 1.3.6.1.4.1.6247.25.1.3.1.1.4
The subnet mask lenght for the destination IP address.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..32  

cdd564RouteNextHopAddress 1.3.6.1.4.1.6247.25.1.3.1.1.5
The next hop IP address for the route.
Status: current Access: read-write
OBJECT-TYPE    
  IpAddress  

cdd564RouteMulticast 1.3.6.1.4.1.6247.25.1.3.1.1.6
If the route is a multicast, packets can be: 1. forwarded 2. filtered If the route is unicast, the field is not applicable.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(0), forward(1), filtered(2)  

cdd564RouteInterface 1.3.6.1.4.1.6247.25.1.3.1.1.7
Routes are destined to the Ethernet interface.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER toEthernet(2)  

cdd564RouteRowStatus 1.3.6.1.4.1.6247.25.1.3.1.1.8
This value is used for status of route: active(1) - The route is active. These values are used to create or delete route: createAndGo(4) - The route is to be created. destroy(6) - The route to be deleted.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER active(1), notInService(2), notReady(3), createAndGo(4), createAndWait(5), destroy(6)  

cdd564Protocols 1.3.6.1.4.1.6247.25.1.4
OBJECT IDENTIFIER    

cdd564IGMPConfig 1.3.6.1.4.1.6247.25.1.4.1
OBJECT IDENTIFIER    

cdd564IGMPServer 1.3.6.1.4.1.6247.25.1.4.1.1
OBJECT IDENTIFIER    

cdd564IGMPQueryPeriod 1.3.6.1.4.1.6247.25.1.4.1.1.1
The IGMP query period, in seconds.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 1..600  

cdd564IGMPMaxResponseTime 1.3.6.1.4.1.6247.25.1.4.1.1.2
The IGMP maximum response time, in seconds.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 1..600  

cdd564IGMPMaxMissBeforeLeavingGroup 1.3.6.1.4.1.6247.25.1.4.1.1.3
The maximum number of missed responses before leaving the IGMP group.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 1..30  

cdd564IGMPTable 1.3.6.1.4.1.6247.25.1.4.1.3
The table for IGMP groups.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Cdd564IGMPEntry

cdd564IGMPEntry 1.3.6.1.4.1.6247.25.1.4.1.3.1
The entry for the IGMP group table.
Status: current Access: not-accessible
OBJECT-TYPE    
  Cdd564IGMPEntry  

cdd564IGMPIndex 1.3.6.1.4.1.6247.25.1.4.1.3.1.1
The index for the IGMP group table.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 1..256  

cdd564IGMPTTL 1.3.6.1.4.1.6247.25.1.4.1.3.1.2
The TTL for the multicast group.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..255  

cdd564IGMPClientState 1.3.6.1.4.1.6247.25.1.4.1.3.1.3
The state for the multicast group.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER idle(1), active(2), closing(3)  

cdd564IGMPSrc 1.3.6.1.4.1.6247.25.1.4.1.3.1.4
The interface from which the multicast group was received.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER ethernet(1), satellite(2)  

cdd564IGMPGroupIPAddress 1.3.6.1.4.1.6247.25.1.4.1.3.1.5
The multicast group address.
Status: current Access: read-only
OBJECT-TYPE    
  IpAddress  

cdd564Maint 1.3.6.1.4.1.6247.25.1.5
OBJECT IDENTIFIER    

cdd564UnitInformation 1.3.6.1.4.1.6247.25.1.5.1
OBJECT IDENTIFIER    

cdd564BootInfo 1.3.6.1.4.1.6247.25.1.5.1.1
The version and revision information for the boot application.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

cdd564Bulk1Info 1.3.6.1.4.1.6247.25.1.5.1.2
The version and revision information for the bulk application in image 1.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

cdd564Bulk2Info 1.3.6.1.4.1.6247.25.1.5.1.3
The version and revision information for the bulk application in image 2.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

cdd564FPGARx1Info 1.3.6.1.4.1.6247.25.1.5.1.4
The version and revision information for the Rx FPGA in image 1.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

cdd564FPGARx2Info 1.3.6.1.4.1.6247.25.1.5.1.5
The version and revision information for the Rx FPGA in image 2.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

cdd564BulkDatabase 1.3.6.1.4.1.6247.25.1.5.2
OBJECT IDENTIFIER    

cdd564BootImage 1.3.6.1.4.1.6247.25.1.5.2.1
Specifies which image will be booted: latest - boots the latest image determined by the most recent build date image 1 - boots image from bulk #1 image 2 - boots image from bulk #2
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER latest(0), image1(1), image2(2)  

cdd564UpgradeImage 1.3.6.1.4.1.6247.25.1.5.2.2
Specifies which image will be overwritten during an upgrade: oldest - overwrites the oldest image determined by build date. image 1 - overwrites image 1 image 2 - overwrites image 2 NOTE: Set this value before performing an upgrade.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER oldest(0), image1(1), image2(2)  

cdd564ParamDatabase 1.3.6.1.4.1.6247.25.1.5.3
OBJECT IDENTIFIER    

cdd564ParamImage 1.3.6.1.4.1.6247.25.1.5.3.1
Specifies if configuration should be read from: paramFile - parameter file stored in flash factoryDefaults - the factory defaults
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER paramFile(1), factoryDefaults(2)  

cdd564SaveParamToFlash 1.3.6.1.4.1.6247.25.1.5.3.2
This is a SET command to save the configuration to the parameter file in flash.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER save(1)  

cdd564ReloadParamFromFlash 1.3.6.1.4.1.6247.25.1.5.3.3
This is a SET command to reload the configuration from the parameter file in flash.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER reload(1)  

cdd564RestoreFactoryDefaults 1.3.6.1.4.1.6247.25.1.5.3.4
This is a SET command that restore the configuration to the factory defaults. *** Imporant *** Setting this command ERASES the parameter file in flash.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER restore(1)  

cdd564RebootUnit 1.3.6.1.4.1.6247.25.1.5.4
OBJECT IDENTIFIER    

cdd564Reboot 1.3.6.1.4.1.6247.25.1.5.4.1
The is a SET command that will reboot the unit. *** Important *** The command will reboot the unit without saving the configuration to the parameter file in flash.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER reboot(1)  

cdd564Statistics 1.3.6.1.4.1.6247.25.1.6
OBJECT IDENTIFIER    

cdd564IPRoutingStatistics 1.3.6.1.4.1.6247.25.1.6.1
OBJECT IDENTIFIER    

cdd564IPRoutingEthernet 1.3.6.1.4.1.6247.25.1.6.1.1
OBJECT IDENTIFIER    

cdd564TotalPacketsToEthernet 1.3.6.1.4.1.6247.25.1.6.1.1.1
The total number of IP packets routed to the Ethernet interface.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cdd564TotalUnicastsToEthernet 1.3.6.1.4.1.6247.25.1.6.1.1.2
The total number of Unicast packets routed to the Ethernet interface.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cdd564TotalMulticastsToEthernet 1.3.6.1.4.1.6247.25.1.6.1.1.3
The total number of Multicast packets routed to the Ethernet interface.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cdd564TotalBroadcastsToEthernet 1.3.6.1.4.1.6247.25.1.6.1.1.4
The total number of Broadcast packets routed to the Ethernet interface.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cdd564TotalPacketsFromEthernet 1.3.6.1.4.1.6247.25.1.6.1.1.5
The total number of IP packets received from the Ethernet interface.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cdd564IPRoutingSatellite 1.3.6.1.4.1.6247.25.1.6.1.2
OBJECT IDENTIFIER    

cdd564TotalPacketsFromSatellite 1.3.6.1.4.1.6247.25.1.6.1.2.1
The total number of IP packets received from the satellite interfaces.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cdd564IPRoutingEndstation 1.3.6.1.4.1.6247.25.1.6.1.3
OBJECT IDENTIFIER    

cdd564TotalPacketsFromEndstation 1.3.6.1.4.1.6247.25.1.6.1.3.1
The total number of packets received from the Endstation to be sent out one of the interfaces.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cdd564TotalPacketsToEndstation 1.3.6.1.4.1.6247.25.1.6.1.3.2
The total number of packets sent to the Endstation from one of the interfaces.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cdd564IPRoutingMisc 1.3.6.1.4.1.6247.25.1.6.1.4
OBJECT IDENTIFIER    

cdd564IGMPPacketsReceived 1.3.6.1.4.1.6247.25.1.6.1.4.1
The total number of IGMP packets received by the endstation.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cdd564IPOptionPacketsReceived 1.3.6.1.4.1.6247.25.1.6.1.4.2
The total number of packets received with IP Options in the IP header.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cdd564IPRoutingDropped 1.3.6.1.4.1.6247.25.1.6.1.5
OBJECT IDENTIFIER    

cdd564TotalDroppedPackets 1.3.6.1.4.1.6247.25.1.6.1.5.1
The total number of packets dropped by the router.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cdd564DroppedPacketsBadIPHeader 1.3.6.1.4.1.6247.25.1.6.1.5.2
The total number of packets dropped by the router because of a bad checksum in the IP header.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cdd564DroppedPacketsBadBufferLength 1.3.6.1.4.1.6247.25.1.6.1.5.3
The total number of packets dropped by the router because of a bad packet buffer length.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cdd564DroppedPacketsBadIPVersion 1.3.6.1.4.1.6247.25.1.6.1.5.4
The total number of packets dropped by the router because of the packet is not IPv4. Note: IPv6 packets are not support by the router.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cdd564DroppedPacketsTTLExpired 1.3.6.1.4.1.6247.25.1.6.1.5.5
The total number of packets dropped by the router because the TTL (time to live) in the IP header had expired (i.e. reached zero).
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cdd564DroppedPacketsNoRoute 1.3.6.1.4.1.6247.25.1.6.1.5.6
The total number of packets dropped by the router because the packet did not match any route in the route table and could not be forwarded.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cdd564DroppedPacketsNoARPEntry 1.3.6.1.4.1.6247.25.1.6.1.5.7
The total number of packets dropped by the router because the ARP table did not have an ARP entry for the packet's next hop.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cdd564DroppedPacketsFilteredMulticast 1.3.6.1.4.1.6247.25.1.6.1.5.8
The total number of multicast packets dropped by the router because the multicast address is not being forwarded.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cdd564DroppedPacketsMulticastDisableGroup 1.3.6.1.4.1.6247.25.1.6.1.5.9
The total number of multicast packets dropped by the router because the multicast group is not being forwarded.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cdd564DroppedPacketsFiltered 1.3.6.1.4.1.6247.25.1.6.1.5.10
The total number of packets dropped by the router for the following reasons: 1. Boot 2. Flow Descriptor 3. Unknown Reason Code 4. Flow Correlator 5. Management Path 6. Ping 7. Access Control 8. Vipersat Multicommand 9. Vipersat Unicommand 10. Codeload 11. Multicast 12. Bad Packet 13. Route 14. Bad Header Len 15. Bad Data Ptr 16. MAC Split Err 17. L3Type Err 18. Local Destination 19. ICMP Filter 20. Port Err 21. Per port route rule
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cdd564DroppedPacketsRouterQueueFull 1.3.6.1.4.1.6247.25.1.6.1.5.11
The total number of packets dropped by the router because the router queue is full.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cdd564IPRoutingClearCounters 1.3.6.1.4.1.6247.25.1.6.1.6
This is a SET command to clear the IP routing counters.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER clear(1)  

cdd564EthernetStatistics 1.3.6.1.4.1.6247.25.1.6.2
OBJECT IDENTIFIER    

cdd564EthernetTxStats 1.3.6.1.4.1.6247.25.1.6.2.1
OBJECT IDENTIFIER    

cdd564EtherTxGoodFrames 1.3.6.1.4.1.6247.25.1.6.2.1.1
The number of transmitted good frames from the Ethernet interface.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cdd564EtherTxMaxCollisions 1.3.6.1.4.1.6247.25.1.6.2.1.2
The number of frames that were NOT transmitted because they encountered the maximum configured collisions. This counter should only increment when network is heavily saturated with traffic.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cdd564EtherTxLateCollisions 1.3.6.1.4.1.6247.25.1.6.2.1.3
The number of frames that were NOT transmitted because they encountered collision outside the normal collision window.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cdd564EtherTxDMAUnderrun 1.3.6.1.4.1.6247.25.1.6.2.1.4
The number of frames that were either NOT transmitted or retransmitted due to Transmit DMA underrun. Underruns occur due to lack of PCI bandwidth resulting in the internal transmit FIFO running dry during the transmission of a frame.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cdd564EtherTxLostCarrierSense 1.3.6.1.4.1.6247.25.1.6.2.1.5
The number of frames transmitted by the device despite the fact that it detected the de-assertion of Transmit Lost Carrier Sense (CRS) during the transmission.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cdd564EtherTxDeferred 1.3.6.1.4.1.6247.25.1.6.2.1.6
The number of frames deferred before transmission due to activity on the link.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cdd564EtherTxSingleCollisions 1.3.6.1.4.1.6247.25.1.6.2.1.7
The number of transmitted frames that encountered only 1 collision.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cdd564EtherTxMultipleCollisions 1.3.6.1.4.1.6247.25.1.6.2.1.8
The number of transmitted frames that encountered more than 1 collision.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cdd564EtherTxTotalCollisions 1.3.6.1.4.1.6247.25.1.6.2.1.9
The total number of collisions that were encountered while attempting to transmit. This count includes late collisions and collisions from frames that encountered maximum collisions.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cdd564EtherTxFlowControlPauseFrames 1.3.6.1.4.1.6247.25.1.6.2.1.10
The number of flow control frames transmitted by the device. This count includes both the XOFF and XON frames transmitted by the device.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cdd564EthernetRxStats 1.3.6.1.4.1.6247.25.1.6.2.2
OBJECT IDENTIFIER    

cdd564EtherRxGoodFrames 1.3.6.1.4.1.6247.25.1.6.2.2.1
The number of frames properly received from the link. It is updated only after actual reception from the link is completed and all data bytes are stored in memory.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cdd564EtherRxCRCErrorFrames 1.3.6.1.4.1.6247.25.1.6.2.2.2
The number of aligned frames discarded due to CRC Errors.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cdd564EtherRxAllignmentErrors 1.3.6.1.4.1.6247.25.1.6.2.2.3
The number of frames that are both misaligned [in other words, CRS de-asserts on a non-octet boundary] and contain a CRC error.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cdd564EtherRxResourceErrors 1.3.6.1.4.1.6247.25.1.6.2.2.4
The number of good frames discarded due to unavailable resources.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cdd564EtherRxFIFOOverrunErrors 1.3.6.1.4.1.6247.25.1.6.2.2.5
The number of frames known to be lost because the internal receive FIFO overflowed [also known as receive overrun]. This can occur if the device is unable to get necessary PCI bandwidth. If the overflow condition persists for more than one frame, the frames that follow the first can also be lost. A frame that was counted as an overrun will not be counted in other error counters like (short frames, misaligned, CRC error).
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cdd564EtherRxCollisionDetectErrors 1.3.6.1.4.1.6247.25.1.6.2.2.6
The number of frames that encountered collision during reception. This is always zero.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cdd564EtherRxShortFrames 1.3.6.1.4.1.6247.25.1.6.2.2.7
The number of received frames that are shorter than the minimum frame length.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cdd564EtherRxFlowControlPauseFrames 1.3.6.1.4.1.6247.25.1.6.2.2.8
The number of flow control frames received by the device. This count includes both XOFF and XON frames received.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cdd564EthernetClearCounters 1.3.6.1.4.1.6247.25.1.6.2.3
Reset all ethernet transmit & receive counters.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER clear(1)  

cdd564SatelliteStatistics 1.3.6.1.4.1.6247.25.1.6.3
OBJECT IDENTIFIER    

cdd564SatelliteRxStatsTable 1.3.6.1.4.1.6247.25.1.6.3.1
The table for Satellite interface statistics.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Cdd564SatelliteRxStatsEntry

cdd564SatelliteRxStatsEntry 1.3.6.1.4.1.6247.25.1.6.3.1.1
The entry for the Satellite interface statistics table.
Status: current Access: not-accessible
OBJECT-TYPE    
  Cdd564SatelliteRxStatsEntry  

cdd564RxStatsIndex 1.3.6.1.4.1.6247.25.1.6.3.1.1.1
The Rx index for the satellite interface, where index can be from 1 to 4.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 1..4  

cdd564RxGoodFrames 1.3.6.1.4.1.6247.25.1.6.3.1.1.2
The total number of good frames received over satellite interface.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cdd564RxHeaderBytes 1.3.6.1.4.1.6247.25.1.6.3.1.1.3
The count of HDLC header bytes received over the satellite interface. HDLC header = Control + HDLC address + Flow ID + CRC
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cdd564RxPayloadBytes 1.3.6.1.4.1.6247.25.1.6.3.1.1.4
The count of payload bytes that were received over satellite interface, excluding any frame overhead.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cdd564RxBadHDLCAddressErrors 1.3.6.1.4.1.6247.25.1.6.3.1.1.5
The count of received frames that did not match any of the Rx HDLC addresses.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cdd564RxPktProcCRCErrors 1.3.6.1.4.1.6247.25.1.6.3.1.1.6
The Packet Processor CRC check is the second CRC check performed after the HDLC CRC check. It is the checksum calculated after Decryption and Payload Decompression. Failures due to 3xDES and Payload Comp are detected at this level.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cdd564RxAbortOctetErrors 1.3.6.1.4.1.6247.25.1.6.3.1.1.7
The count of aborted frames and octet error frames. Aborted frame: A frame is aborted when the frame is not complete and is terminated prematurely with the Abort signal, which is 8 consecutive '1's. Octet error: A frames that was not on a byte boudary or on a multiple of 8-bit boundary.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cdd564RxOverrunErrors 1.3.6.1.4.1.6247.25.1.6.3.1.1.8
The count of received frames that exceeded the maximum frame length of 2K bytes or overflowed the buffer which stores complete HDLC frames.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cdd564RxHDLCCRCErrors 1.3.6.1.4.1.6247.25.1.6.3.1.1.9
The HDLC CRC is the first stage of the CRC check, before 3xDES and paylod Decompression. It indicates any errors due to the satellite link only.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cdd564RxInvalidFlowIDErrors 1.3.6.1.4.1.6247.25.1.6.3.1.1.10
The number of frames received where the flow ID did not match to a valid flow descriptor.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cdd564RxSARReassembleErrors 1.3.6.1.4.1.6247.25.1.6.3.1.1.11
The number of frames corresponding to a packet which had undergone segmentation and encountered an error in reassembly.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cdd564RxHeaderDecompressionErrors 1.3.6.1.4.1.6247.25.1.6.3.1.1.12
The number of frames with a compressed IP header that encountered an error in decompressing (rebuilding) the full IP header.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cdd564RxMemoryAlignmentErrors 1.3.6.1.4.1.6247.25.1.6.3.1.1.13
The number of frames which were incorrectly transferred (frame too small) from the Rx FPGA.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cdd564RxCRCErrors 1.3.6.1.4.1.6247.25.1.6.3.1.1.14
The number of frames with a CRC error detected by the Rx FPGA.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cdd564SatelliteClearCounters 1.3.6.1.4.1.6247.25.1.6.3.2
This is a SET command for clearing all the Satellite statistic counters.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER clear(1)  

cdd564Config 1.3.6.1.4.1.6247.25.1.7
OBJECT IDENTIFIER    

cdd564Rx 1.3.6.1.4.1.6247.25.1.7.1
OBJECT IDENTIFIER    

cdd564RxTable 1.3.6.1.4.1.6247.25.1.7.1.1
The table of Demodulators.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Cdd564RxEntry

cdd564RxEntry 1.3.6.1.4.1.6247.25.1.7.1.1.1
The entry for the Demodulator table.
Status: current Access: not-accessible
OBJECT-TYPE    
  Cdd564RxEntry  

cdd564RxTableIndex 1.3.6.1.4.1.6247.25.1.7.1.1.1.1
The index for the Rx table, where index can be from 1 to 4.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 1..4  

cdd564RxFEC 1.3.6.1.4.1.6247.25.1.7.1.1.1.2
Rx FEC type where: 0 = Uncoded 6 = Turbo
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER uncoded(0), turbo(6)  

cdd564RxDemodulation 1.3.6.1.4.1.6247.25.1.7.1.1.1.3
Rx demodulation type, where: 1 = QPSK 3 = 8-PSK 4 = 16-QAM
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER demodQPSK(1), demod8PSK(3), demod16QAM(4)  

cdd564RxCodeRate 1.3.6.1.4.1.6247.25.1.7.1.1.1.4
Rx code rate, where 4 = Rate 3/4 5 = Rate 7/8 6 = Rate 0.95 7 = Rate 1/1 (Uncoded)
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER rate3over4(4), rate7over8(5), rate095(6), uncoded(7)  

cdd564RxDataRate 1.3.6.1.4.1.6247.25.1.7.1.1.1.5
Rx data rate in bps (Varies based on chart below.) Units = bps Resolution = 1 bps FEC Type Modulation Code Rate Data Rate High Rate -------- ----------- ---------- --------------------- --------- Turbo QPSK Rate 3/4 16.0 Kbps to 4.5 Mbps N/A Turbo QPSK Rate 7/8 16.0 Kbps to 5.0 Mbps 5.25 Mbps Turbo QPSK Rate 0.95 16.0 Kbps to 5.0 Mbps 5.667 Mbps Turbo 8-PSK Rate 3/4 16.0 Kbps to 5.0 Mbps 6.75 Mbps Turbo 8-PSK Rate 7/8 16.0 Kbps to 5.0 Mbps 7.875 Mbps Turbo 8-PSK Rate 0.95 16.0 Kbps to 5.0 Mbps 8.5 Mbps Turbo 16-QAM Rate 3/4 16.0 Kbps to 5.0 Mbps 9.0 Mbps Turbo 16-QAM Rate 7/8 16.8 Kbps to 5.0 Mbps 9.98 Mbps
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 16000..9980000  

cdd564RxFrequency 1.3.6.1.4.1.6247.25.1.7.1.1.1.6
Rx frequency for L-Band and IF-Band modes. L-Band is 950 MHz to 1950 MHz. IF-Band is 50 MHz to 90 MHz and 100 MHz to 180 MHz. Units = Hz. Resolution = 100 Hz.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 50000000..90000000 | 100000000..180000000 | 950000000..1950000000  

cdd564RxAcquisitionSweepWidth 1.3.6.1.4.1.6247.25.1.7.1.1.1.7
Rx +/- acquisition sweep range of demodulator, in KHz, ranging from: +/- 1 to +/- 32 KHz (rates < 625 ksym/second) or +/- 1 to 200 KHz (rates >= 625 ksym/second)
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 1..200  

cdd564RxDescrambling 1.3.6.1.4.1.6247.25.1.7.1.1.1.8
Rx descrambler state, where: 0 = Off 1 = On (default descrambler type) 2 = On - IESS-315 (Turbo only)
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER off(0), onDefault(1), onIESS315(2)  

cdd564RxBufferSize 1.3.6.1.4.1.6247.25.1.7.1.1.1.9
Rx buffer size, where: 0 = Buffer disabled (Clock mode = Rx satellite)
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(0)  

cdd546RxSpectrumInversion 1.3.6.1.4.1.6247.25.1.7.1.1.1.10
Rx spectrum inversion, where: 0 = Normal 1 = Rx spectrum inverted
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER normal(0), inverted(1)  

cdd564RxDataInversion 1.3.6.1.4.1.6247.25.1.7.1.1.1.11
Invert receive data, where: 0 = Normal 1 = Inverted
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER normal(0), inverted(1)  

cdd564RxEbNoAlarmPoint 1.3.6.1.4.1.6247.25.1.7.1.1.1.12
Rx Eb/No alarm point in 0.1 dB, with a range between 0.1 dB and 16 dB. Units = 0.1 dB Resolution = 0.1 dB
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 1..160  

cdd564RxRecenterBuffer 1.3.6.1.4.1.6247.25.1.7.1.1.1.13
This is a SET command that recenters the receive Plesiochronous/Doppler buffer.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER recenter(1)  

cdd564RxSymbolRate 1.3.6.1.4.1.6247.25.1.7.1.1.1.14
Rx symbol rate in symbols per second (sym) Units = sym Resolution = 1 sym
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 5000..3000000  

cdd564AlarmMask 1.3.6.1.4.1.6247.25.1.7.2
OBJECT IDENTIFIER    

cdd564AlarmMaskTable 1.3.6.1.4.1.6247.25.1.7.2.1
Description.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Cdd564AlarmMaskEntry

cdd564AlarmMaskEntry 1.3.6.1.4.1.6247.25.1.7.2.1.1
Description.
Status: current Access: not-accessible
OBJECT-TYPE    
  Cdd564AlarmMaskEntry  

cdd564AlarmMaskIndex 1.3.6.1.4.1.6247.25.1.7.2.1.1.1
The index for the Demodulator.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 1..4  

cdd564AGCAlarmMask 1.3.6.1.4.1.6247.25.1.7.2.1.1.2
Rx AGC alarm mask, where: 0 = Unmasked 1 = Masked
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER active(0), masked(1)  

cdd564EbNoAlarmMask 1.3.6.1.4.1.6247.25.1.7.2.1.1.3
Eb/No alarm mask, where: 0 = Unmasked 1 = Masked
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER active(0), masked(1)  

cdd564LNBAlarmMask 1.3.6.1.4.1.6247.25.1.7.2.1.1.5
LNB alarm mask, where: 0 = Unmasked 1 = Masked
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER active(0), masked(1)  

cdd564Reference 1.3.6.1.4.1.6247.25.1.7.3
OBJECT IDENTIFIER    

cdd564ReferenceFrequency 1.3.6.1.4.1.6247.25.1.7.3.1
External reference frequency, where: 0 = Internal 10 MHz
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER int10MHz(0)  

cdd564InternalReferenceAdjust 1.3.6.1.4.1.6247.25.1.7.3.2
Internal Reference Adjust, from -999 to +999. Units = KHz
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER -999..999  

cdd564LNB 1.3.6.1.4.1.6247.25.1.7.4
OBJECT IDENTIFIER    

cdd564LNBTable 1.3.6.1.4.1.6247.25.1.7.4.1
The table for LNBs.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Cdd564LNBEntry

cdd564LNBEntry 1.3.6.1.4.1.6247.25.1.7.4.1.1
The entry for the LNBs table.
Status: current Access: not-accessible
OBJECT-TYPE    
  Cdd564LNBEntry  

cdd564LNBIndex 1.3.6.1.4.1.6247.25.1.7.4.1.1.1
The index for the LNB..
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 1..4  

cdd564LNBDCPower 1.3.6.1.4.1.6247.25.1.7.4.1.1.2
LNB power control, where: 0 = Off 1 = On, 13V LNB voltage 2 = On, 18V LNB voltage 3 = On, 24V LNB voltage
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER off(0), on13volts(1), on18volts(2), on24volts(3)  

cdd564LNB10MHzReference 1.3.6.1.4.1.6247.25.1.7.4.1.1.3
LNB 10MHz frequency reference, where: 0 = Disable LNB 10MHz reference 1 = Enable LNB 10MHz reference
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disable(0), enable(1)  

cdm564LLNBLowCurrentLimit 1.3.6.1.4.1.6247.25.1.7.4.1.1.4
LNB lower alarm limit for current, between 10 and 400 mA.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 10..400  

cdd564LNBHighCurrentLimit 1.3.6.1.4.1.6247.25.1.7.4.1.1.5
LNB upper alarm limit for current, between 50 and 600 mA.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 50..600  

cdd564LNBLOFrequency 1.3.6.1.4.1.6247.25.1.7.4.1.1.6
LNB receieve LO frequency, in the range of 3000 to 65000 MHz. Setting a 0 disables the feature. Terminal Frequency = LNB_LO +/- Rx_Frequency (depending on High/Low Mix)
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0 | 3000..65000  

cdd564LNBLOMix 1.3.6.1.4.1.6247.25.1.7.4.1.1.7
LO frequency mix, where: 0 = Low-side mix 1 = High-side mix
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER lowSideMix(0), highSideMix(1)  

cdd564Monitor 1.3.6.1.4.1.6247.25.1.8
OBJECT IDENTIFIER    

cdd564UnitMonitor 1.3.6.1.4.1.6247.25.1.8.1
OBJECT IDENTIFIER    

cdd564SerialNumber 1.3.6.1.4.1.6247.25.1.8.1.1
Unit's 9-digit serial number.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

cdd564SoftwareRevision 1.3.6.1.4.1.6247.25.1.8.1.2
Unit returns the value of the internal software revision installed in the unit, in the form of x.x.x.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

cdd564ModelNumber 1.3.6.1.4.1.6247.25.1.8.1.3
Unit's model number.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..999  

cdd564UnitAlarm 1.3.6.1.4.1.6247.25.1.8.1.4
Modem Unit Faults: Value Description of unit fault 0 No faults 1 +5 Volt power supply 2 +12 Volt power supply 3 -5 Volt power supply 4 +23 Volt power supply 5 -12 Volt power supply 6 Rx 1st LO synthesize lock 7 Rx 2nd LO synthesize lock 8 Ref PLL lock 9 EEPROM checksum error
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER noFaults(0), powerSupply5volts(1), powerSupply12volts(2), powerSupplyNeg5volts(3), powerSupply23volts(4), powerSupplyNeg12volts(5), rx1stLOSynthesizerLock(6), rx2ndLOSynthesizerLock(7), refPLLLock(8), checksumErrorEEPROM(9)  

cdd564Temperature 1.3.6.1.4.1.6247.25.1.8.1.5
Unit returns the value of the internal temperature, in degrees Celsius.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER -99..99  

cdd564RxMonitor 1.3.6.1.4.1.6247.25.1.8.2
OBJECT IDENTIFIER    

cdd564RxMonitorTable 1.3.6.1.4.1.6247.25.1.8.2.1
The table for monitoring demodulators.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Cdd564RxMonitorEntry

cdd564RxMonitorEntry 1.3.6.1.4.1.6247.25.1.8.2.1.1
The entry for the demoduator monitor table.
Status: current Access: not-accessible
OBJECT-TYPE    
  Cdd564RxMonitorEntry  

cdd564RxMonitorIndex 1.3.6.1.4.1.6247.25.1.8.2.1.1.1
The index for the demodulator monitor table.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 1..4  

cdd564RxAlarm 1.3.6.1.4.1.6247.25.1.8.2.1.1.2
Modem RX Traffic Faults Value Description of status parameter 0 Rx Traffic OK 1 Demodulator unlocked 3 AGC Alarm - signal out of range 10 Buffer underflow 11 Buffer overflow 13 Eb/No alarm 15 AIS detected on incoming data
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER rxTrafficOK(0), demodulatorUnlocked(1), agcAlarmSignalOutOfRange(3), bufferUnderflow(10), bufferOverflow(11), ebNoAlarm(13), aisDetectedOnIncomingData(15)  

cdd564RxEbNo 1.3.6.1.4.1.6247.25.1.8.2.1.1.3
Unit returns the value of Eb/No, between 0 and 16 db. Units = 0.1 dB Resolution 0.1 dB Returns 999 if demod is unlocked. For values greater than 16 dB, the reply will be 160.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..160 | 999  

cdd564RxSignalLevel 1.3.6.1.4.1.6247.25.1.8.2.1.1.4
Unit returns the value of the Rx signal level, in dBm, between -20 and -99 dBm, Returns -100 if signal is less than -99dBm. Returns -19 if signal is greater than -20dBm.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER -100 | -99..-20 | -19  

cdd564RxFreqOffset 1.3.6.1.4.1.6247.25.1.8.2.1.1.5
Unit returns the value of the measured frequency offset of the carrier being demodulated in Hz. Units = Hz. Resolution 100 Hz. Range = -200,000 Hz to 0 Hz and 0 Hz to 200,000 Hz.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER -200000..200000 | 999900  

cddRxBERMultiplier 1.3.6.1.4.1.6247.25.1.8.2.1.1.7
Estimated corrected BER. The BER is calculated by multiplying the Multiplier by 10E-10. Calculuation: RxBER = (Multiplier) * 0.0000000001 Returns 2147483647 (max int) if demod is unlocked.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..999999999 | 2147483647  

cdd564LNBMonitor 1.3.6.1.4.1.6247.25.1.8.3
OBJECT IDENTIFIER    

cdd564LNBMonitorTable 1.3.6.1.4.1.6247.25.1.8.3.1
The table for monitoring LNBs.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Cdd564LNBMonitorEntry

cdd564LNBMonitorEntry 1.3.6.1.4.1.6247.25.1.8.3.1.1
The entry for the LNBs monitoring table.
Status: current Access: not-accessible
OBJECT-TYPE    
  Cdd564LNBMonitorEntry  

cdd564LNBMonitorIndex 1.3.6.1.4.1.6247.25.1.8.3.1.1.1
The index for the LNBs monitoring table.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 1..4  

cdd564LNBAlarm 1.3.6.1.4.1.6247.25.1.8.3.1.1.2
LNB alarms Value Description of status parameter 0 No LNB faults 7 LNB current 9 LNB voltage
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER noLNBfaults(0), lnbCurrent(7), lnbVoltage(9)  

cdd564LNBCurrent 1.3.6.1.4.1.6247.25.1.8.3.1.1.3
Indicates the value of the LNB current, between 0 and 999 mA.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..999  

cdd564LNBVoltage 1.3.6.1.4.1.6247.25.1.8.3.1.1.4
Indicates the value of the LNB voltage, between 0 and 30 volts. Units = 0.1 volts If not available, response is 0.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..300  

cdd564LNBTerminalRxFreq 1.3.6.1.4.1.6247.25.1.8.3.1.1.5
Terminal Rx frequency = LNB LO +/- Rx_Frequency (depending on LO mix) Units = 100 Hz Resolution = 100 Hz Returns 0 if LNB_LO is zero.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..999999999  

cdd564StoredEvents 1.3.6.1.4.1.6247.25.1.8.4
OBJECT IDENTIFIER    

cdd564StoredEventsTable 1.3.6.1.4.1.6247.25.1.8.4.1
The table of stored events for all four demods.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Cdd564StoredEventsEntry

cdd564StoredEventsEntry 1.3.6.1.4.1.6247.25.1.8.4.1.1
The entry for stored events table for all 4 demods.
Status: current Access: not-accessible
OBJECT-TYPE    
  Cdd564StoredEventsEntry  

cdd564EventDemod 1.3.6.1.4.1.6247.25.1.8.4.1.1.1
The demodulator index for which event log is being returned.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 1..4  

cdd564EventIndex 1.3.6.1.4.1.6247.25.1.8.4.1.1.2
The index for a demod's stored events table.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 1..255  

cdd564EventDescription 1.3.6.1.4.1.6247.25.1.8.4.1.1.3
Event description string with the following format seprated by commas: 1. Date in form dd/mm/yy, where: dd = day of the month (01 to 31) mm = month (01 to 12) yy = year (00 to 99) 2. Time in form hh:mm:ss, where: hh = hours (00 to 23) mm = minutes (00 to 59) ss = seconds (00 to 59) 3. Event Type in form xxxxx, where xxxxx is Clear = fault cleared Fault = fault occurred Info = information 4. Texual Description of Event
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

cdd564ClearAllStoredEvents 1.3.6.1.4.1.6247.25.1.8.4.2
This is a SET command to clear the event log for one of the four demods (1 - 4).
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 1..4  

cdd564StoredStatistics 1.3.6.1.4.1.6247.25.1.8.5
OBJECT IDENTIFIER    

cdd564StoredStatisticsTable 1.3.6.1.4.1.6247.25.1.8.5.1
The table of stored statistics for all four demods.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Cdd564StoredStatisticsEntry

cdd564StoredStatisticsEntry 1.3.6.1.4.1.6247.25.1.8.5.1.1
The entry for stored statistics table for all four demods.
Status: current Access: not-accessible
OBJECT-TYPE    
  Cdd564StoredStatisticsEntry  

cdd564StatisticDemod 1.3.6.1.4.1.6247.25.1.8.5.1.1.1
The demod index for which statistics table is being returned.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 1..4  

cdd564StatisticIndex 1.3.6.1.4.1.6247.25.1.8.5.1.1.2
The index in one of the four demod's stored statistics table.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 1..255  

cdd564StatisticDate 1.3.6.1.4.1.6247.25.1.8.5.1.1.3
The date of the statistic in the form dd/mm/yy, where: dd = day of the month (01 to 31) mm = month (01 to 12) yy = year (00 to 99)
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

cdd564StatisticTime 1.3.6.1.4.1.6247.25.1.8.5.1.1.4
The time of the statistic in the form hh:mm:ss, indicating the time from midnight, where: hh = hours (00 to 23) mm = minutes (00 to 59) ss = seconds (00 to 59)
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

cdd564StatisticAvgEbNo 1.3.6.1.4.1.6247.25.1.8.5.1.1.5
Minimum Eb/No during sample period. Units = 0.1 dB. Returns 999 if demod was unlocked during sample period.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..160 | 999  

cdd564StatisticMinEbNo 1.3.6.1.4.1.6247.25.1.8.5.1.1.6
Minimum Eb/No during sample period. Units = 0.1 dB. Returns 999 if demod was unlocked during sample period.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..160 | 999  

cdd564StoredStatisticsConfigTable 1.3.6.1.4.1.6247.25.1.8.5.2
The configuration for the stored statistics (per Demod).
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Cdd564StoredStatisticsConfigEntry

cdd564StoredStatisticsConfigEntry 1.3.6.1.4.1.6247.25.1.8.5.2.1
The entry for the stored statistics configuration table.
Status: current Access: not-accessible
OBJECT-TYPE    
  Cdd564StoredStatisticsConfigEntry  

cdd564StoredStatisticsConfigIndex 1.3.6.1.4.1.6247.25.1.8.5.2.1.1
The index for the Demodulator.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 1..4  

cdd564StatisticsSampleInterval 1.3.6.1.4.1.6247.25.1.8.5.2.1.2
Used to set the sample interval for the statistics logging function, where the enumerated lists goes from 0 to 9 in 10 minute steps. Setting 0 disables the statistics logging function.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(0), mins10(1), mins20(2), mins30(3), mins40(4), mins50(5), mins60(6), mins70(7), mins80(8), mins90(9)  

cdd564ClearAllStoredStatistics 1.3.6.1.4.1.6247.25.1.8.5.3
This is a SET command to clear the statistics log for one of the four demods (1 - 4).
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 1..4  

cdd564Util 1.3.6.1.4.1.6247.25.1.9
OBJECT IDENTIFIER    

cdd564RTCDate 1.3.6.1.4.1.6247.25.1.9.4
A date in the form dd/mm/yy, where dd = day of the month (01 to 31) mm = month (01 to 12) yy = year (00 to 99)
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

cdd564RTCTime 1.3.6.1.4.1.6247.25.1.9.5
A time in the form hh:mm:ss, indicating the time from midnight, where: hh = hours (00 to 23) mm = minutes (00 to 59) ss = seconds (00 to 59)
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

cdd564CircuitIDTable 1.3.6.1.4.1.6247.25.1.9.6
The table for Circuit IDs (Per Demod).
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Cdd564CircuitIDEntry

cdd564CircuitIDEntry 1.3.6.1.4.1.6247.25.1.9.6.1
The entry for the circuit ID table.
Status: current Access: not-accessible
OBJECT-TYPE    
  Cdd564CircuitIDEntry  

cdd564CircuitIDIndex 1.3.6.1.4.1.6247.25.1.9.6.1.1
The index for the Demodulator.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 1..4  

cdd564CircuitID 1.3.6.1.4.1.6247.25.1.9.6.1.2
Sets or queries the user-defined Circuit ID string, which is a fixed length of 24 characters. Valid characters include: Space ( ) * + - , . / 0 thru 9 and A thru Z.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

cdd564Notifications 1.3.6.1.4.1.6247.25.2
OBJECT IDENTIFIER    

cdd564NotificationsPrefix 1.3.6.1.4.1.6247.25.2.0
OBJECT IDENTIFIER    

cdd564UnitAlarmNotification 1.3.6.1.4.1.6247.25.2.0.1
Trap for Unit alarms.
Status: current Access: read-write
NOTIFICATION-TYPE    

cdd564RxAlarmNotification 1.3.6.1.4.1.6247.25.2.0.2
Trap for Rx alarms.
Status: current Access: read-write
NOTIFICATION-TYPE    

cdd564LNBAlarmNotification 1.3.6.1.4.1.6247.25.2.0.3
Trap for LNB alarms.
Status: current Access: read-write
NOTIFICATION-TYPE    

cdd564Conformance 1.3.6.1.4.1.6247.25.3
OBJECT IDENTIFIER    

cdd564Groups 1.3.6.1.4.1.6247.25.3.1
OBJECT IDENTIFIER    

cdd564ObjectsGroup 1.3.6.1.4.1.6247.25.3.1.1
CDD-564 Objects Group.
Status: current Access: read-write
OBJECT-GROUP    

cdd564NotificationsGroup 1.3.6.1.4.1.6247.25.3.1.2
CDD-564 Trap Group.
Status: current Access: read-write
NOTIFICATION-GROUP    

cdd564Compliances 1.3.6.1.4.1.6247.25.3.2
OBJECT IDENTIFIER    

cdd564Compliance 1.3.6.1.4.1.6247.25.3.2.1
CDD-564 Compliance.
Status: current Access: read-write
MODULE-COMPLIANCE