CADANT-CMTS-SYSTEM-MIB

File: CADANT-CMTS-SYSTEM-MIB.mib (135008 bytes)

Imported modules

SNMPv2-SMI SNMPv2-CONF SNMPv2-TC
INET-ADDRESS-MIB IF-MIB CADANT-PRODUCTS-MIB
CADANT-TC DOCS-QOS3-MIB DOCS-IF-MIB
SNMP-FRAMEWORK-MIB

Imported symbols

OBJECT-TYPE MODULE-IDENTITY Counter32
Integer32 IpAddress Unsigned32
MODULE-COMPLIANCE OBJECT-GROUP TruthValue
DisplayString MacAddress DateAndTime
RowStatus InetAddressType InetAddress
InetAddressIPv4 InetAddressIPv6 InterfaceIndexOrZero
cadSystem CardId AdminState
ServerType OverloadThreshold AdminSrcAddrType
BitRate TenthdB SnmpAdminString
SnmpEngineID

Defined Types

CadSnmpRemoteEngineEntry  
SEQUENCE    
  cadSnmpRemoteEngineIpAddress IpAddress
  cadSnmpRemoteEnginePortNumber Integer32
  cadSnmpRemoteEngineID SnmpEngineID
  cadSnmpRemoteUserName SnmpAdminString
  cadSnmpRemoteEngineType INTEGER
  cadSnmpRemoteEngineStatus RowStatus

CadSysDictionaryEntry  
SEQUENCE    
  cadSysDictionaryTableId Unsigned32
  cadSysDictionaryName DisplayString
  cadSysDictionaryDynamic TruthValue
  cadSysDictionaryNumberEntries Integer32
  cadSysDictionaryCurrentVer Unsigned32
  cadSysDictionaryPersistentVer Unsigned32
  cadSysDictionaryModuleVer Unsigned32

CadCosToQosMappingEntry  
SEQUENCE    
  cadCosToQosMappingIndex Integer32
  cadCosUpMaxTrafficBurst Unsigned32
  cadCosDnMaxTrafficBurst Unsigned32
  cadCosDnMinReservedRate BitRate
  cadCosUpMinReservedPkt Integer32
  cadCosDnMinReservedPkt Integer32
  cadCosUpTosAndMask OCTET STRING
  cadCosUpTosOrMask OCTET STRING
  cadCosDnMaxLatency Unsigned32
  cadCosDnPriority Integer32
  cadCosDnPeakTrafficRate BitRate
  cadCosUpPeakTrafficRate BitRate

CadSysKeyChainKeyEntry  
SEQUENCE    
  cadSysKeyChainName OCTET STRING
  cadSysKeyChainKeySequenceId Unsigned32
  cadSysKeyChainKey OCTET STRING
  cadSysKeyChainKeyAcceptStartTime DateAndTime
  cadSysKeyChainKeyAcceptStopTime DateAndTime
  cadSysKeyChainKeyAcceptInfiniteLifetime TruthValue
  cadSysKeyChainKeySendStartTime DateAndTime
  cadSysKeyChainKeySendStopTime DateAndTime
  cadSysKeyChainKeySendInfiniteLifetime TruthValue
  cadSysKeyChainKeyRowStatus RowStatus

CadSysBannerMotdEntry  
SEQUENCE    
  cadSysBannerMotdLine Integer32
  cadSysBannerMotdText DisplayString
  cadSysBannerMotdRowStatus RowStatus

CadSysBannerLoginEntry  
SEQUENCE    
  cadSysBannerLoginLine Integer32
  cadSysBannerLoginText DisplayString
  cadSysBannerLoginRowStatus RowStatus

CadSysBannerExecEntry  
SEQUENCE    
  cadSysBannerExecLine Integer32
  cadSysBannerExecText DisplayString
  cadSysBannerExecRowStatus RowStatus

CadSysBannerIncomingEntry  
SEQUENCE    
  cadSysBannerIncomingLine Integer32
  cadSysBannerIncomingText DisplayString
  cadSysBannerIncomingRowStatus RowStatus

CadSysServerEntry  
SEQUENCE    
  cadSysServerType ServerType
  cadSysServerAdminState AdminState

CadSysPatchParamEntry  
SEQUENCE    
  cadSysPatchParamIndex Integer32
  cadSysPatchParamName DisplayString
  cadSysPatchParamValue DisplayString
  cadSysPatchParamDescription DisplayString
  cadSysPatchParamRowStatus RowStatus

CadSysSourceAddressEntry  
SEQUENCE    
  cadSysSourceAddressIndex AdminSrcAddrType
  cadSysSourceInterfaceIpv4IfIndex InterfaceIndexOrZero
  cadSysSourceAddressIpv4Address InetAddressIPv4
  cadSysSourceInterfaceIpv6IfIndex InterfaceIndexOrZero
  cadSysSourceAddressIpv6Address InetAddressIPv6

CadLaesMdTimestampModeEntry  
SEQUENCE    
  cadLaesMdTimestampModeInetAddrType InetAddressType
  cadLaesMdTimestampModeInetAddr InetAddress
  cadLaesMdTimestampModRowStatus RowStatus

CadSysMICSecondarySecretEntry  
SEQUENCE    
  cadSysMICSecondarySecretIndex INTEGER
  cadSysMICSecondarySecretString OCTET STRING
  cadSysMICSecondarySecretStatus RowStatus

Defined Values

cadSystemMib 1.3.6.1.4.1.4998.1.1.5.1
Arris E6000 system parameters and constants
MODULE-IDENTITY    

cadSysParams 1.3.6.1.4.1.4998.1.1.5.1.1
OBJECT IDENTIFIER    

cadSysSystem 1.3.6.1.4.1.4998.1.1.5.1.2
OBJECT IDENTIFIER    

cadSysControl 1.3.6.1.4.1.4998.1.1.5.1.3
OBJECT IDENTIFIER    

cadSysSnmp 1.3.6.1.4.1.4998.1.1.5.1.4
OBJECT IDENTIFIER    

cadSysBootParams 1.3.6.1.4.1.4998.1.1.5.1.5
OBJECT IDENTIFIER    

cadSysReload 1.3.6.1.4.1.4998.1.1.5.1.6
OBJECT IDENTIFIER    

cadSysImage 1.3.6.1.4.1.4998.1.1.5.1.7
OBJECT IDENTIFIER    

cadSysDictionary 1.3.6.1.4.1.4998.1.1.5.1.8
OBJECT IDENTIFIER    

cadSysConfiguration 1.3.6.1.4.1.4998.1.1.5.1.9
OBJECT IDENTIFIER    

cadCosToQosMapping 1.3.6.1.4.1.4998.1.1.5.1.10
OBJECT IDENTIFIER    

cadSysKeyChain 1.3.6.1.4.1.4998.1.1.5.1.11
OBJECT IDENTIFIER    

cadSysProcPolicingConfig 1.3.6.1.4.1.4998.1.1.5.1.13
OBJECT IDENTIFIER    

cadSysProcPolicingCounts 1.3.6.1.4.1.4998.1.1.5.1.14
OBJECT IDENTIFIER    

cadSysBanner 1.3.6.1.4.1.4998.1.1.5.1.15
OBJECT IDENTIFIER    

cadSysServer 1.3.6.1.4.1.4998.1.1.5.1.16
OBJECT IDENTIFIER    

cadSysPatchParams 1.3.6.1.4.1.4998.1.1.5.1.17
OBJECT IDENTIFIER    

cadSysMtceParams 1.3.6.1.4.1.4998.1.1.5.1.19
OBJECT IDENTIFIER    

cadSysDataServer 1.3.6.1.4.1.4998.1.1.5.1.21
OBJECT IDENTIFIER    

cadSysSourceAddress 1.3.6.1.4.1.4998.1.1.5.1.22
OBJECT IDENTIFIER    

cadSysLicenseControl 1.3.6.1.4.1.4998.1.1.5.1.23
OBJECT IDENTIFIER    

cadLaesMdTimestampMode 1.3.6.1.4.1.4998.1.1.5.1.24
OBJECT IDENTIFIER    

cadSysSharedSecret 1.3.6.1.4.1.4998.1.1.5.1.25
OBJECT IDENTIFIER    

cadSysSyncInterval 1.3.6.1.4.1.4998.1.1.5.1.1.1
Nominal time between transmission of SYNC messages. (ref 6.3.2)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..200  

cadSysUCDInterval 1.3.6.1.4.1.4998.1.1.5.1.1.2
Time between transmission of UCD messages. (ref 6.3.3)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..2000  

cadSysMaxMAPPending 1.3.6.1.4.1.4998.1.1.5.1.1.3
The number of mini-slots that a CMTS is allowed to map into the future. (ref 6.3.4)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..4096  

cadSysRangingInterval 1.3.6.1.4.1.4998.1.1.5.1.1.4
Time between transmission of broadcast Ranging requests. (ref 7.3.3)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..2000  

cadSysInvitedRangingRetries 1.3.6.1.4.1.4998.1.1.5.1.1.5
Number of retries on inviting ranging requests. (ref 9.2.4)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 16  

cadSysRegistrationRequestRetries 1.3.6.1.4.1.4998.1.1.5.1.1.6
Number of retries on registration requests/responses.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 3  

cadSysCMMAPProcessingTime 1.3.6.1.4.1.4998.1.1.5.1.1.7
Time provided between arrival of the last bit of a MAP at a CM and effectiveness of that MAP. (ref 7.1.1)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 200..2000  

cadSysCMRangingResponseProcessingTime 1.3.6.1.4.1.4998.1.1.5.1.1.8
Minimum tile allowed fro a CM following receipt of a rangin response before it is expected to reply to an invited ranging request.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..200  

cadSysCMConfiguration 1.3.6.1.4.1.4998.1.1.5.1.1.9
Maximum time allowed for a CM, following receipt of a configuration file, to send a Registration Request to a CMTS.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 30..2000  

cadSysT5Timeout 1.3.6.1.4.1.4998.1.1.5.1.1.10
Wait for Upstream CHannel Change response.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..2000  

cadSysT6Timeout 1.3.6.1.4.1.4998.1.1.5.1.1.11
Wait for REG-RSP and REG-ACK
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..3000  

cadSysMiniSlotSize 1.3.6.1.4.1.4998.1.1.5.1.1.12
Size of mini-slotfor upstream transmission. Must be a power of 2 (in units of the Timebase Tick).
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 32..300  

cadSysDSxRequestRetries 1.3.6.1.4.1.4998.1.1.5.1.1.13
Number of Timeout Retries on DSA/DSC/DSD Requests.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 3  

cadSysDSxResponseRetries 1.3.6.1.4.1.4998.1.1.5.1.1.14
Number of Timeout Retries on DSA/DSC/DSD Responses.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 3  

cadSysT7Timeout 1.3.6.1.4.1.4998.1.1.5.1.1.15
Wait for DSA/DSC/DSD Response timeout.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..1000  

cadSysT8Timeout 1.3.6.1.4.1.4998.1.1.5.1.1.16
Wait for DSA/DSC/DSD Acknowledge timeout.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..300  

cadSysT9Timeout 1.3.6.1.4.1.4998.1.1.5.1.1.17
Registration timeout, the time allowed between the CMTS sending a RNG-RSP(success) to a CM, and receiving a REG-REQ from that same CM.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 15..1500  

cadSysT10Timeout 1.3.6.1.4.1.4998.1.1.5.1.1.18
Wait for Transaction End timeout.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..3000  

cadSysT11Timeout 1.3.6.1.4.1.4998.1.1.5.1.1.19
Wait for a DCC Response on the old channel.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..300  

cadSysT13Timeout 1.3.6.1.4.1.4998.1.1.5.1.1.20
Maximum holding time for QOS resources for DCC.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..1000  

cadSysDCCREQRetries 1.3.6.1.4.1.4998.1.1.5.1.1.21
Number of retries on Dynamic Channel Change Request.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 3  

cadSysMICEnable 1.3.6.1.4.1.4998.1.1.5.1.1.22
Enable MIC checking on the CMTS.
Status: current Access: read-write
OBJECT-TYPE    
  TruthValue  

cadSysMICAuthString 1.3.6.1.4.1.4998.1.1.5.1.1.23
Encrypted MIC Authentication
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(0..64)  

cadSysAutoRecoveryEnable 1.3.6.1.4.1.4998.1.1.5.1.1.24
Enable automatic recovery of card/port/software in case of component failure.
Status: current Access: read-write
OBJECT-TYPE    
  TruthValue  

cadSysActiveIpAddress 1.3.6.1.4.1.4998.1.1.5.1.1.25
Ip Address of the active control complex.
Status: current Access: read-write
OBJECT-TYPE    
  IpAddress  

cadSysSpOperMode 0.1.2.4.5.6.7.8.9.10.11.12.14.15.16.17.18.19.20.21.22.23.24.25.26.27.28.29.30.31.1.3.6.1.4.1.4998.1.1.5.1.1.26
Special operational mode. Value of 1 indicates the mode is enabled. dqossf10cms - Allow 1.0 CMs to be stored in DocsQosServiceFlowEntry adjrxpwrctl - Allow rx power control to be adjusted by mod type usage enbudptcpfltr - Allow combining of Udp and Tcp messages in a single filter upce - Allow Upstream Packet Classifier Enforcement use16ForDSPeakTrafficRate - use the defunct TLV type 16 for DS peak traffic rate cpeNacksForceCmReset - - Force CM reset upon receiving 3 consecutive CPE NACKs loadBalUnbondedVoipOn - Allow load balancing for non-bonded voice calls limitUsRngRspFreqOff - Prevent CM from using an upstream frequency beyond 42 MHz upDownTrapIfDescrOff - Allow linkup or linkdown trap to include ifDescr ofdmSparingCleanupOff - Allow automatically reset any D3.1 CMs in a cable-mac that has an OFDM channel on that DCAM in the CM's RCS after a failover or fallback cmstatusoperational - Support DOCS-IF-MIB draft-05 (cw26)'s change to docsIfCmtsCmStatusValue, such that online modems take on a value of operational(8) at the CMTS. If disabled, operational(8) is not used and online modems take on a value of registrationComplete(6) at the CMTS. docsis20test - Allow running of DOCSIS 2.0 Tests. showCmFormatCVOff - show cable modem is formatted per CableVision's requirements if set to 0. docsis10plusOff - DOCSIS 1.0+ support is enabled if set to 0. downstreamOverrideOn - downstream overrides are disabled if this is set to 0. supressDCDOff - DCDs are suppressed if set to 0. virtualCmOff - support for virtual modems is enabled if set to 0. bpiHybridOff - Allow DOCSIS 1.1 modems to operate in BPI instead of BPI+ if this is set to 0. oneDCmDSMaxTrafBurstOn - Override Max Traffic Burst for DOCSIS 1.1 modems on a 1D CAM with E6000 setting if this is set to 0. docsis30ReqTxPolicyChkOff - Override DOCSIS 3.0 checking for Request/Transmission Policy TLV on upstream flows.
Status: current Access: read-write
OBJECT-TYPE    
  BITS dqossf10cms(0), adjrxpwrctl(1), enbudptcpfltr(2), upce(3), use16ForDSPeakTrafficRate(4), cpeNacksForceCmReset(5), loadBalUnbondedVoipOn(6), upDownTrapIfDescrOff(7), ofdmSparingCleanupOff(8), limitUsRngRspFreqOff(9), reserved10(10), cmstatusoperational(11), reserved12(12), docsis20test(13), reserved14(14), reserved15(15), reserved16(16), reserved17(17), reserved18(18), reserved19(19), reserved20(20), showCmFormatCVOff(21), bpiDynamicMulticastOff(22), docsis10plusOff(23), downstreamOverrideOn(24), supressDCDOff(25), virtualCmOff(26), bpiHybridOff(27), oneDCmDSMaxTrafBurstOn(28), docsis30ReqTxPolicyChkOff(29), reserved30(30), reserved31(31)  

cadSysCountsCollectionRate 1.3.6.1.4.1.4998.1.1.5.1.1.27
The period, in minutes, in which every count in the CMTS is to be collected. If this object is set to 0, counts collection will be disabled.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 0 | 15..1440  

cadSysMaxQoSActiveTimeout 1.3.6.1.4.1.4998.1.1.5.1.1.28
Defines the maximum QoS Active Timeout the E6000 is willing to allow. If a larger value is received in a CM request the E6000 will return this value instead in the response (Reference DOCSIS RFI Section c.2.2.5.6). Note a value of 0 is infinite and is therefore treated as the largest value in the range.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..65535  

cadSysMaxQoSAdmittedTimeout 1.3.6.1.4.1.4998.1.1.5.1.1.29
Defines the maximum QoS Admitted Timeout the E6000 is willing to allow. If a larger value is received in a CM request the E6000 will return this value instead in the response (Reference DOCSIS RFI Section c.2.2.5.7). Note a value of 0 is infinite and is therefore treated as the largest value in the range.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..65535  

cadSysAllow10CmConcatenation 1.3.6.1.4.1.4998.1.1.5.1.1.30
Defines whether or not the E6000 will allow a modem operating in DOCSIS 1.0 mode to utilize concatenation. If this value is false and a modem operating in 1.0 mode sends up a modem capability indicating concatenation the E6000 will respond by turning that capability off. If this value is true the modem will be returned whatever it requests (on or off).
Status: current Access: read-write
OBJECT-TYPE    
  TruthValue  

cadSysAllow10CmFragmentation 1.3.6.1.4.1.4998.1.1.5.1.1.31
Defines whether or not the E6000 will allow a modem operating in DOCSIS 1.0 mode to utilize fragmentation. If this value is false and a modem operating in 1.0 mode sends up a modem capability indicating fragmentation the E6000 will respond by turning that capability off. If this value is true the modem will be returned whatever it requests (on or off).
Status: current Access: read-write
OBJECT-TYPE    
  TruthValue  

cadSysPercentAddtlDsBwAllocated 1.3.6.1.4.1.4998.1.1.5.1.1.32
This value of this setting is used to make a percentage increase to a dynamic downstream service flows maximum traffic rate. This is flexiblity actually causes the E6000 to operate outside the DOCSIS 1.1 specification by allocating and allowing more traffic than was actually requested. The initial reason for providing this capability is to mask problems produced in the Voice environment where devices have been seen to violate the traffic rates. Examples of this are MTAs that overuse the QI bit for long durations thus overdriving the downstream burst interval and the Neura IPDT gateway introducing an additional 0.5% inband signaling to the DS voice flow
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..5  

cadSysMaxTrafBurstFor11CMs 1.3.6.1.4.1.4998.1.1.5.1.1.33
This is the default value that will be used to populate the Maximum Traffic Burst for a 1.1 modem unless the maximum traffic burst TLV is explicitly provided in either the modems Request or in a Service Class Name definition. This value is being made programmable for 2 reasons: 1) So that it can be set to the DOCSIS default of 3044 for CableLabs testing and 2) it can be tuned for real world applications.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..2147483647  

cadSysFanSpeedControlEnable 1.3.6.1.4.1.4998.1.1.5.1.1.34
Enable automatic fan speed control.
Status: obsolete Access: read-write
OBJECT-TYPE    
  TruthValue  

cadSysFlaplistPowerAdjustThreshold 1.3.6.1.4.1.4998.1.1.5.1.1.35
The threshold is used to monitor the power adjust in the flap list. For a range request received that results in a power adjust exceeding the threshold value will cause the counter cadIfCmtsCmCountsPowerAdjExceedsThreshold to be incremented. If the threshold is set to 0, the monitoring of power adjustment in the flap list is disabled.
Status: current Access: read-write
OBJECT-TYPE    
  TenthdB 0 | 10..100  

cadSysRemoteFSEnable 1.3.6.1.4.1.4998.1.1.5.1.1.36
Indicates whether the active SCM should allow mounting the the filesystems of the standby SCM.
Status: current Access: read-write
OBJECT-TYPE    
  TruthValue  

cadSysRemotePortEnable 1.3.6.1.4.1.4998.1.1.5.1.1.37
Indicates whether the active SCM should allow redirection of the serial console of the standby SCM.
Status: current Access: read-write
OBJECT-TYPE    
  TruthValue  

cadSysTcpSmoothingValue1D8U 1.3.6.1.4.1.4998.1.1.5.1.1.38
TCP smoothing value to be programmed into hardware on 1D8U CAMs.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32  

cadSysTcpSmoothingValue2D12U 1.3.6.1.4.1.4998.1.1.5.1.1.39
TCP smoothing value to be programmed into hardware on 2D12U CAMs.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32  

cadSysModemLossThreshold 1.3.6.1.4.1.4998.1.1.5.1.1.40
Minimum modem threshold triggering detection of an upstream channel lockup.
Status: deprecated Access: read-write
OBJECT-TYPE    
  Unsigned32 10..2000  

cadSysPeakTrafRateFor11CMs 1.3.6.1.4.1.4998.1.1.5.1.1.41
This is the default value that will be used to populate the Peak Traffic Rate for a 1.1 modem configuration file unless the peak traffic rate is explicitly provided by a Service Class Name definition.
Status: obsolete Access: read-write
OBJECT-TYPE    
  BitRate  

cadSysCpeHostAuthorization 1.3.6.1.4.1.4998.1.1.5.1.1.44
This variable enables the CPE Host Authorization feature.
Status: current Access: read-write
OBJECT-TYPE    
  TruthValue  

cadSysMaxUcdBurstLength 1.3.6.1.4.1.4998.1.1.5.1.1.46
This variable limits the maximum UCD burst length.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 2048..16128  

cadSysLO1LeakDetect 1.3.6.1.4.1.4998.1.1.5.1.1.47
This variable controls LO1 leak detection on the DMM.
Status: current Access: read-write
OBJECT-TYPE    
  TruthValue  

cadMtcmConditionalOverride 1.3.6.1.4.1.4998.1.1.5.1.1.48
If set to 'true', for a MAC Domain configured for MTCM enabled operation, the E6000 will set a registering MTCM-capable CM to be MTCM disabled (via REG-RSP message) unless at least one of the config file's service flows was specifically configured to have the Bonded bit set in the Required attribute mask (in which case the CM will be set to MTCM enabled). If set to false, standard DOCSIS 3.0 operation will result.
Status: current Access: read-write
OBJECT-TYPE    
  TruthValue  

cadSysDelayedCpeLearning 1.3.6.1.4.1.4998.1.1.5.1.1.49
This setting only applies to modems that have BPI enabled. When set to false(2), CPE learning is enabled during registration when BPI initialization is initiated for those modems using BPI. When set to true(1), CPE learning is delayed during registration until BPI initialization is complete for those modems using BPI. For modems not using BPI, CPE learning is enabled when registration is complete.
Status: current Access: read-write
OBJECT-TYPE    
  TruthValue  

cadSysModPriDsInRccEnabled 1.3.6.1.4.1.4998.1.1.5.1.1.52
Enable modifying primary Downstream channel in RCC of Reg-Rsp-MP. Refer ECN 690.
Status: current Access: read-write
OBJECT-TYPE    
  TruthValue  

cadSysSendTccRefIdPerFragment 1.3.6.1.4.1.4998.1.1.5.1.1.53
Settings for sending the Transmit Channel Configuration (TCC) Reference sub-type 46.1 for type 46 TCC fragmentation. If 'true', sends 46.1 Ref ID in every type 46 TCC fragment; If 'false', only sends 46.1 Ref ID in the first TCC fragment (DOCSIS Compliant).
Status: current Access: read-write
OBJECT-TYPE    
  TruthValue  

cadSysPeakTrRateUpstream 1.3.6.1.4.1.4998.1.1.5.1.1.54
This object enables support for Peak Traffic Rate in the upstream direction.
Status: current Access: read-write
OBJECT-TYPE    
  TruthValue  

cadSysAllowAmbiguityOverride 1.3.6.1.4.1.4998.1.1.5.1.1.55
This object enables ambiguity resolution channel-override actions.
Status: current Access: read-write
OBJECT-TYPE    
  TruthValue  

cadSysUnicastNpUsAcquisition 1.3.6.1.4.1.4998.1.1.5.1.1.56
This object enables unicast non-primary upstream channel acquisition.
Status: current Access: read-write
OBJECT-TYPE    
  TruthValue  

cadSysMacMoveBlockedOnRcptDhcpPkt 1.3.6.1.4.1.4998.1.1.5.1.1.57
MAC movement is blocked on receipt of DHCP packets
Status: current Access: read-write
OBJECT-TYPE    
  TruthValue  

cadSysTftpProxy 1.3.6.1.4.1.4998.1.1.5.1.1.58
This parameter provides a global enable for the TFTP Enforce and Dynamic Shared Secret features. In order for the cadIfMacDomainTftpEnforce and cadIfMacDomainDynamicSecret parameters to take effect, this parameter must also be enabled. This parameter can also limit those features to only IPv4 transfers or IPv6 transfers.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disable(0), enable(1), ipv4only(2), ipv6only(3)  

cadSysFanSpeedLevel 1.3.6.1.4.1.4998.1.1.5.1.1.59
Set the fan speed for the chassis.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..255  

cadSys1x1onCmAcPwrLossEnabled 1.3.6.1.4.1.4998.1.1.5.1.1.60
This object enables/disables the CMTS reaction to a AC Power Loss CM-STATUS. If true, the CMTS will wait until cadSys1x1onCmAcPwrLossHoldoff expires, and then the CMTS will place the CM into a 1x1 (US/DS) channel mode to conserve CM battery power. If false, the CMTS will not place a CM that reports an AC Power Loss into 1x1 mode.
Status: current Access: read-write
OBJECT-TYPE    
  TruthValue  

cadSysFlapListInsertionThreshold 1.3.6.1.4.1.4998.1.1.5.1.1.61
This object shows the number of seconds between successive ranging attempts that must pass before the modem is counted as flapped. The modem must have also been in a provisioning or registered state before the ranging request.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 60..86400  

cadSysAES128Enable 1.3.6.1.4.1.4998.1.1.5.1.1.62
Enables AES-128 Cryptography Suite for BPI+ when true.
Status: current Access: read-write
OBJECT-TYPE    
  TruthValue  

cadSysContact 1.3.6.1.4.1.4998.1.1.5.1.2.1
The textual identification of the contact person for this managed node, together with information on how to contact this person. If no contact information is known, the value is the zero-length string.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

cadSysName 1.3.6.1.4.1.4998.1.1.5.1.2.2
An administratively-assigned name for this managed node. By convention, this is the node's fully-qualified domain name. If the name is unknown, the value is the zero-length string.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

cadSysLocation 1.3.6.1.4.1.4998.1.1.5.1.2.3
The physical location of this node (e.g., `telephone closet, 3rd floor'). If the location is unknown, the value is the zero-length string.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

cadSysWriteMem 1.3.6.1.4.1.4998.1.1.5.1.3.1
This variable always returns FALSE upon reading. When set to TRUE, the configuration data currently resident in volatile memory (RAM) is written to persistent memory (NVRAM).
Status: current Access: read-write
OBJECT-TYPE    
  TruthValue  

cadSysEraseMem 1.3.6.1.4.1.4998.1.1.5.1.3.2
This variable always returns FALSE upon reading. When set to TRUE, the configuration data currently resident in persistent memory (NVRAM) is erased.
Status: current Access: read-write
OBJECT-TYPE    
  TruthValue  

cadSysEnableAuthenTraps 1.3.6.1.4.1.4998.1.1.5.1.4.1
Indicates whether the SNMP entity is permitted to generate authentication traps.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enable(1), disabled(2)  

cadSysSnmpReadAheadMax 1.3.6.1.4.1.4998.1.1.5.1.4.2
This value is the maximum number of records to read ahead
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 0..20  

cadSysSnmpRefreshTime 1.3.6.1.4.1.4998.1.1.5.1.4.3
This value represents how old a database record can be to be used.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 0..1200  

cadSnmpRemoteEngineTable 1.3.6.1.4.1.4998.1.1.5.1.4.4
Table containing information of remote SNMP engines.
Status: deprecated Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    CadSnmpRemoteEngineEntry

cadSnmpRemoteEngineEntry 1.3.6.1.4.1.4998.1.1.5.1.4.4.1
Entry containing information of remote SNMP engines.
Status: current Access: not-accessible
OBJECT-TYPE    
  CadSnmpRemoteEngineEntry  

cadSnmpRemoteEngineIpAddress 1.3.6.1.4.1.4998.1.1.5.1.4.4.1.1
The IP address of a remote SNMP engine with which this user can communicate.
Status: current Access: not-accessible
OBJECT-TYPE    
  IpAddress  

cadSnmpRemoteEnginePortNumber 1.3.6.1.4.1.4998.1.1.5.1.4.4.1.2
The UDP port of a remote SNMP engine with which this user can communicate.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 0..65535  

cadSnmpRemoteEngineID 1.3.6.1.4.1.4998.1.1.5.1.4.4.1.3
An SNMP engine's administratively-unique identifier of a remote SNMP engine with which this user can communicate.
Status: deprecated Access: read-create
OBJECT-TYPE    
  SnmpEngineID  

cadSnmpRemoteUserName 1.3.6.1.4.1.4998.1.1.5.1.4.4.1.4
A human readable string representing the name of the user of a remote SNMP engine.
Status: current Access: read-create
OBJECT-TYPE    
  SnmpAdminString Size(1..32)  

cadSnmpRemoteEngineType 1.3.6.1.4.1.4998.1.1.5.1.4.4.1.5
The type to indicate the remote engineID is manually configured or internally detected via SNMP V3 Informs probe response.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER manual(1), auto(2)  

cadSnmpRemoteEngineStatus 1.3.6.1.4.1.4998.1.1.5.1.4.4.1.6
The status of this conceptual row.
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

cadSysBootMacAddress 1.3.6.1.4.1.4998.1.1.5.1.5.1
Mac address of system controller
Status: current Access: read-only
OBJECT-TYPE    
  MacAddress  

cadSysBootFpIpAddress 1.3.6.1.4.1.4998.1.1.5.1.5.2
Ip address of E6000 front panel ethernet port
Status: current Access: read-write
OBJECT-TYPE    
  IpAddress  

cadSysBootFpSubnetMask 1.3.6.1.4.1.4998.1.1.5.1.5.3
E6000 front port interface subnet mask
Status: current Access: read-write
OBJECT-TYPE    
  IpAddress  

cadSysBootDefaultGateway 1.3.6.1.4.1.4998.1.1.5.1.5.6
Default gateway
Status: current Access: read-write
OBJECT-TYPE    
  IpAddress  

cadSysBootTimeOffset 1.3.6.1.4.1.4998.1.1.5.1.5.7
Time offset (seconds) from UTC
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

cadSysBootTimeServer 1.3.6.1.4.1.4998.1.1.5.1.5.8
Ip address of TOD server
Status: current Access: read-only
OBJECT-TYPE    
  IpAddress  

cadSysBootTimeServerConnType 1.3.6.1.4.1.4998.1.1.5.1.5.9
Protocol (tcp/udp) used to connect to TOD server
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER tcp(1), udp(2), none(3)  

cadSysBootStartupApplication 1.3.6.1.4.1.4998.1.1.5.1.5.10
Startup mode of the E6000
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER bootprobe(1), bootapplication(4)  

cadSysBootStartupDelay 1.3.6.1.4.1.4998.1.1.5.1.5.11
Delay (in seconds) allowing changes before booting application
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..60  

cadSysBootSelection 1.3.6.1.4.1.4998.1.1.5.1.5.12
Bootloader to use (1 or 2)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..2  

cadSysBootBaud 1.3.6.1.4.1.4998.1.1.5.1.5.13
Baud rate of front panel serial port
Status: deprecated Access: read-only
OBJECT-TYPE    
  Integer32  

cadSysBootFpBIpAddress 1.3.6.1.4.1.4998.1.1.5.1.5.15
Ip address of E6000 side B front panel ethernet port
Status: current Access: read-write
OBJECT-TYPE    
  IpAddress  

cadSysBootParity 1.3.6.1.4.1.4998.1.1.5.1.5.16
Serial parity of console port. Valid values are N (no parity), E (even parity), and O (odd parity).
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(1)  

cadSysReloadOperation 1.3.6.1.4.1.4998.1.1.5.1.6.1
Control object for E6000 reload, reading this object always returns none(99)
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER reloadImage(1), reloadCommit(2), reloadActive(3), reloadHitless(4), reloadWritemem(5), reloadErasemem(6), reloadPatchInstall(7), reloadPatchRemove(8), reloadPatchApply(9), none(99)  

cadSysReloadImageName 1.3.6.1.4.1.4998.1.1.5.1.6.2
Image name to use in reloadImage operation
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

cadSysReloadStatus 0.1.3.6.1.4.1.4998.1.1.5.1.6.3
Status object for E6000 reload
Status: current Access: read-only
OBJECT-TYPE    
  BITS idle(0), inProgress(1), localCheckImage(2), localCommit(3), remoteCommit(4), remoteCopyImage(5), remoteCheckImage(6), patchInstall(7), localReboot(8), patchRemove(9), remoteFirmwareUpdate(10), firmwareUpdate(11), waitStandby(12), remotePatchInstall(13), writeMem(14), bundling(15), unbundling(16), complete(17), abort(18), remotePatchRemove(19), remoteWriteMem(20), eraseMem(21), remoteEraseMem(22), preloadCams(23), localInstallImage(24), remoteInstallImage(25), localPreloadRsm(26), remotePreloadRsm(27), remoteCommitRsm(28), copyImage(29), remoteFirmwareUpdateRsm(30), patchApplyCheck(31), waitSoftswitch(32), waitSpareCamsReset(33), waitCamsReset(34)  

cadSysReloadStatusDescription 1.3.6.1.4.1.4998.1.1.5.1.6.4
Textual description of reload status
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

cadSysReloadPatchName 1.3.6.1.4.1.4998.1.1.5.1.6.5
Patch image name to use in patch operations
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

cadSysImageFile 1.3.6.1.4.1.4998.1.1.5.1.7.1
Image filename for current E6000 image
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

cadSysImageId 1.3.6.1.4.1.4998.1.1.5.1.7.2
Image identifier for current E6000 image
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

cadSysImageName 1.3.6.1.4.1.4998.1.1.5.1.7.3
Image name for current E6000 image
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

cadSysImageComponentCount 1.3.6.1.4.1.4998.1.1.5.1.7.4
Image component count for current E6000 image
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

cadSysDictionaryTable 1.3.6.1.4.1.4998.1.1.5.1.8.1
Table describing internal state of database.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    CadSysDictionaryEntry

cadSysDictionaryEntry 1.3.6.1.4.1.4998.1.1.5.1.8.1.1
Describes the internal state of an individual table.
Status: current Access: not-accessible
OBJECT-TYPE    
  CadSysDictionaryEntry  

cadSysDictionaryTableId 1.3.6.1.4.1.4998.1.1.5.1.8.1.1.1
Internal identifier for this MIB data.
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32  

cadSysDictionaryName 1.3.6.1.4.1.4998.1.1.5.1.8.1.1.2
Internal name for this MIB data.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

cadSysDictionaryDynamic 1.3.6.1.4.1.4998.1.1.5.1.8.1.1.3
Indicates whether table is persistent or volatile only.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

cadSysDictionaryNumberEntries 1.3.6.1.4.1.4998.1.1.5.1.8.1.1.4
Current number of rows contained in the MIB table.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

cadSysDictionaryCurrentVer 1.3.6.1.4.1.4998.1.1.5.1.8.1.1.5
Current internal dynamic version number of the MIB table.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

cadSysDictionaryPersistentVer 1.3.6.1.4.1.4998.1.1.5.1.8.1.1.6
Current internal version number of the MIB table on flash.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

cadSysDictionaryModuleVer 1.3.6.1.4.1.4998.1.1.5.1.8.1.1.7
Current internal version number of the schema of the MIB table.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

cadSysConfigSaveTime 1.3.6.1.4.1.4998.1.1.5.1.9.1
The date and time of the last write of the configuration to nvram.
Status: current Access: read-only
OBJECT-TYPE    
  DateAndTime  

cadCosToQosMappingTable 1.3.6.1.4.1.4998.1.1.5.1.10.9
Table of COS to QOS Mapping data
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    CadCosToQosMappingEntry

cadCosToQosMappingEntry 1.3.6.1.4.1.4998.1.1.5.1.10.9.1
This entry contains all of the data to map 1.0 COS to 1.1 QOS parameters.
Status: current Access: not-accessible
OBJECT-TYPE    
  CadCosToQosMappingEntry  

cadCosToQosMappingIndex 1.3.6.1.4.1.4998.1.1.5.1.10.9.1.1
The upstream 1.0 equivalent of the (1.1) DOCS-QOS3-MIB object docsQosParamSetMaxTrafficBurst
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 1..16  

cadCosUpMaxTrafficBurst 1.3.6.1.4.1.4998.1.1.5.1.10.9.1.2
The upstream 1.0 equivalent of the (1.1) DOCS-QOS3-MIB object docsQosParamSetMaxTrafficBurst
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32  

cadCosDnMaxTrafficBurst 1.3.6.1.4.1.4998.1.1.5.1.10.9.1.3
The downstream 1.0 equivalent of the (1.1) DOCS-QOS3-MIB object docsQosParamSetMaxTrafficBurst
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32  

cadCosDnMinReservedRate 1.3.6.1.4.1.4998.1.1.5.1.10.9.1.4
The downstream 1.0 equivalent of the (1.1) DOCS-QOS3-MIB object docsQosParamSetMinReservedRate
Status: current Access: read-write
OBJECT-TYPE    
  BitRate  

cadCosUpMinReservedPkt 1.3.6.1.4.1.4998.1.1.5.1.10.9.1.5
The upstream 1.0 equivalent of the (1.1) DOCS-QOS3-MIB object docsQosParamSetMinReservedPkt
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..65535  

cadCosDnMinReservedPkt 1.3.6.1.4.1.4998.1.1.5.1.10.9.1.6
The downstream 1.0 equivalent of the (1.1) DOCS-QOS3-MIB object docsQosParamSetMinReservedPkt
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..65535  

cadCosUpTosAndMask 1.3.6.1.4.1.4998.1.1.5.1.10.9.1.7
The upstream 1.0 equivalent of the (1.1) DOCS-QOS3-MIB object docsQosParamSetTosAndMask
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(1)  

cadCosUpTosOrMask 1.3.6.1.4.1.4998.1.1.5.1.10.9.1.8
The upstream 1.0 equivalent of the (1.1) DOCS-QOS3-MIB object docsQosParamSetTosOrMask
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(1)  

cadCosDnMaxLatency 1.3.6.1.4.1.4998.1.1.5.1.10.9.1.9
The upstream 1.0 equivalent of the (1.1) DOCS-QOS3-MIB object docsQosParamSetMaxLatency
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32  

cadCosDnPriority 1.3.6.1.4.1.4998.1.1.5.1.10.9.1.10
The downstream channel priority to use. A -1 indicates that the current method of using the upstream channel priority should be used.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 -1 | 0..7  

cadCosDnPeakTrafficRate 1.3.6.1.4.1.4998.1.1.5.1.10.9.1.11
Peak traffic rate shaped to while traffic still conforms to the policing parameters (Tmax and Burst). If the peak rate is set to a value greater than Tmax, then the traffic will be shaped to the peak rate until the traffic is non-conforming to the policing parameters, and then the traffic will be shaped to the Tmax rate. If the peak rate is less than the Tmax for a flow, then all traffic for that flow will shaped to the Tmax rate. Setting the peak rate to a value of 0 will result in all flows being limited to Tmax at all times. Setting the peak rate to a value of 0xffffffff will result in flows having virtually unlimited bandwidth until their burst size is used up. This parameter only has meaning for flows on downstreams that are shaped.
Status: current Access: read-write
OBJECT-TYPE    
  BitRate  

cadCosUpPeakTrafficRate 1.3.6.1.4.1.4998.1.1.5.1.10.9.1.12
Peak traffic rate shaped to while traffic still conforms to the policing parameters (Tmax and Burst). If the peak rate is set to a value greater than Tmax, then the traffic will be shaped to the peak rate until the traffic is non-conforming to the policing parameters, and then the traffic will be shaped to the Tmax rate. If the peak rate is less than the Tmax for a flow, then all traffic for that flow will shaped to the Tmax rate. Setting the peak rate to a value of 0 will result in all flows being limited to Tmax at all times. Setting the peak rate to a value of 0xffffffff will result in flows having virtually unlimited bandwidth until their burst size is used up. This parameter only has meaning for upstream flows.
Status: current Access: read-write
OBJECT-TYPE    
  BitRate  

cadSysKeyChainKeyTable 1.3.6.1.4.1.4998.1.1.5.1.11.1
Table describing key-chain key provisioned data.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    CadSysKeyChainKeyEntry

cadSysKeyChainKeyEntry 1.3.6.1.4.1.4998.1.1.5.1.11.1.1
Describes the provisioned data for a key in a key-chain.
Status: current Access: not-accessible
OBJECT-TYPE    
  CadSysKeyChainKeyEntry  

cadSysKeyChainName 1.3.6.1.4.1.4998.1.1.5.1.11.1.1.1
The key-chain name.
Status: current Access: not-accessible
OBJECT-TYPE    
  OCTET STRING Size(1..16)  

cadSysKeyChainKeySequenceId 1.3.6.1.4.1.4998.1.1.5.1.11.1.1.2
The sequence id of the key.
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32 0..255  

cadSysKeyChainKey 1.3.6.1.4.1.4998.1.1.5.1.11.1.1.3
The key string.
Status: current Access: read-create
OBJECT-TYPE    
  OCTET STRING Size(0..16)  

cadSysKeyChainKeyAcceptStartTime 1.3.6.1.4.1.4998.1.1.5.1.11.1.1.4
The start time when this key is valid for received packets.
Status: current Access: read-create
OBJECT-TYPE    
  DateAndTime  

cadSysKeyChainKeyAcceptStopTime 1.3.6.1.4.1.4998.1.1.5.1.11.1.1.5
The stop time when this key is no longer valid for received packets.
Status: current Access: read-create
OBJECT-TYPE    
  DateAndTime  

cadSysKeyChainKeyAcceptInfiniteLifetime 1.3.6.1.4.1.4998.1.1.5.1.11.1.1.6
If this value is set to true, the key has an infinite lifetime for received packets. Otherwise use the accept start and stop time to determine the lifetime.
Status: current Access: read-create
OBJECT-TYPE    
  TruthValue  

cadSysKeyChainKeySendStartTime 1.3.6.1.4.1.4998.1.1.5.1.11.1.1.7
The start time when this key is valid for sending packets.
Status: current Access: read-create
OBJECT-TYPE    
  DateAndTime  

cadSysKeyChainKeySendStopTime 1.3.6.1.4.1.4998.1.1.5.1.11.1.1.8
The stop time when this key is no longer valid for sending packets.
Status: current Access: read-create
OBJECT-TYPE    
  DateAndTime  

cadSysKeyChainKeySendInfiniteLifetime 1.3.6.1.4.1.4998.1.1.5.1.11.1.1.9
If this value is set to true, the key has an infinite lifetime for sending packets. Otherwise use the send start and stop time to determine the lifetime.
Status: current Access: read-create
OBJECT-TYPE    
  TruthValue  

cadSysKeyChainKeyRowStatus 1.3.6.1.4.1.4998.1.1.5.1.11.1.1.10
The row status variable used according to row installation and removal convention. In our case, we have simplified this to the usage of only the following states - active, createAndGo, and destroy. Other three states notInService, notReady and createAndWait are not permitted.
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

cadSysProcRouterControlGlobalPacketRate 1.3.6.1.4.1.4998.1.1.5.1.13.1
The maximum permitted global protocol packet throttle rate to the Router Control processor.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 0..65535  

cadSysProcArpPacketRate 1.3.6.1.4.1.4998.1.1.5.1.13.2
The maximum permitted ARP packet rate to the Router Control processor.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 0..65535  

cadSysProcDhcpPacketRate 1.3.6.1.4.1.4998.1.1.5.1.13.3
The maxmimu permitted DHCP packet rate to the Router Control processor.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 0..65535  

cadSysProcIcmpPacketRate 1.3.6.1.4.1.4998.1.1.5.1.13.4
The maximum permitted ICMP(IPv4) packet rate to the Router Control processor.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 0..65535  

cadSysProcOspfPacketRate 1.3.6.1.4.1.4998.1.1.5.1.13.5
The maximum permitted OSPFv2 packet rate to the Router Control processor.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 0..65535  

cadSysProcRipPacketRate 1.3.6.1.4.1.4998.1.1.5.1.13.6
The maximum permitted RIP packet rate to the Router Control processor.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 0..65535  

cadSysProcIgmpPacketRate 1.3.6.1.4.1.4998.1.1.5.1.13.7
The maximum permitted IGMP packet rate to the Router Control processor.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 0..65535  

cadSysProcRouterControlOtherPacketRate 1.3.6.1.4.1.4998.1.1.5.1.13.8
The other protocol packet rate to the Router Control processor.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 0..65535  

cadSysProcSnmpPacketRate 1.3.6.1.4.1.4998.1.1.5.1.13.10
The SNMP packet rate to the System Control processor.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 0..65535  

cadSysProcTftpPacketRate 1.3.6.1.4.1.4998.1.1.5.1.13.11
The TFTP packet rate to the processor.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 0..65535  

cadSysProcIsisPacketRate 1.3.6.1.4.1.4998.1.1.5.1.13.12
The IS-IS packet rate to the processor.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 0..65535  

cadSysProcNdPacketRate 1.3.6.1.4.1.4998.1.1.5.1.13.13
The maximum permitted Neighbor Discover (ND) packet throttle rate to the Router Control processor. This includes IPv6 Router Solicitation, Router Advertise, Neighbor Solicitation, Neighbor Advertise, and Redirect messages.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 0..65535  

cadSysProcDhcpIpv6PacketRate 1.3.6.1.4.1.4998.1.1.5.1.13.14
The maximum permitted DHCP (Ipv6) packet throttle rate to the Router Control processor.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 0..65535  

cadSysProcIcmpIpv6PacketRate 1.3.6.1.4.1.4998.1.1.5.1.13.15
The maximum permitted ICMP (Ipv6 other than Neighbor Discover and MLD) packet throttle rate to the Router Control processor.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 0..65535  

cadSysProcMldPacketRate 1.3.6.1.4.1.4998.1.1.5.1.13.16
The maximum permitted MLD (version 1 and version 2) packet throttle rate to the Router Control processor.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 0..65535  

cadSysProcBgpPacketRate 1.3.6.1.4.1.4998.1.1.5.1.13.17
The maximum permitted BGP packet throttle rate to the Router Control processor.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 0..65535  

cadSysProcPimPacketRate 1.3.6.1.4.1.4998.1.1.5.1.13.18
The maximum permitted PIM packet throttle rate to the Router Control processor.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 0..65535  

cadSysProcSnmpCmPacketRate 1.3.6.1.4.1.4998.1.1.5.1.13.19
The maximum permitted SNMP (from CMs) packet throttle rate to the Router Control processor.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 0..65535  

cadSysProcCopsPacketRate 1.3.6.1.4.1.4998.1.1.5.1.13.20
The maximum permitted Cops packet throttle rate to the Router Control processor.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 0..65535  

cadSysProcTelnetPacketRate 1.3.6.1.4.1.4998.1.1.5.1.13.21
The maximum permitted Telnet packet throttle rate to the Router Control processor.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 0..65535  

cadSysProcOspfv3PacketRate 1.3.6.1.4.1.4998.1.1.5.1.13.22
The maximum permitted OSPFv3 packet rate to the Router Control processor.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 0..65535  

cadSysProcTftpIpv6PacketRate 1.3.6.1.4.1.4998.1.1.5.1.13.23
The TFTP (IPv6) packet rate to the processor.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 0..65535  

cadSysProcEventIcmpPacketRate 1.3.6.1.4.1.4998.1.1.5.1.13.24
The maximum permitted ICMP event packet rate to the Router Control processor.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 0..65535  

cadSysProcEventNoRoutePacketRate 1.3.6.1.4.1.4998.1.1.5.1.13.25
The maximum permitted No Route event packet rate to the Router Control processor.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 0..65535  

cadSysProcEventIcmpIpv6PacketRate 1.3.6.1.4.1.4998.1.1.5.1.13.26
The maximum permitted ICMP (IPv6) event packet rate to the Router Control processor.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 0..65535  

cadSysProcEventNoRouteIpv6PacketRate 1.3.6.1.4.1.4998.1.1.5.1.13.27
The maximum permitted No Route (IPv6) event packet rate to the Router Control processor.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 0..65535  

cadSysProcEventArpPacketRate 1.3.6.1.4.1.4998.1.1.5.1.13.28
The maximum permitted ARP event packet rate to the Router Control processor.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 0..65535  

cadSysProcEventNdPacketRate 1.3.6.1.4.1.4998.1.1.5.1.13.29
The maximum permitted ND event packet rate to the Router Control processor.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 0..65535  

cadSysProcEventTtlPacketRate 1.3.6.1.4.1.4998.1.1.5.1.13.30
The maximum permitted TTL event packet rate to the Router Control processor.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 0..65535  

cadSysProcEventTtlIpv6PacketRate 1.3.6.1.4.1.4998.1.1.5.1.13.31
The maximum permitted TTL (IPv6) event packet rate to the Router Control processor.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 0..65535  

cadSysProcEventDadPacketRate 1.3.6.1.4.1.4998.1.1.5.1.13.32
The maximum permitted DAD event packet rate to the Router Control processor.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 0..65535  

cadSysProcEventDefaultPacketRate 1.3.6.1.4.1.4998.1.1.5.1.13.33
The maximum permitted Default event packet rate to the Router Control processor.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 0..65535  

cadSysProcLdpPacketRate 1.3.6.1.4.1.4998.1.1.5.1.13.34
The LDP (UDP and TCP) packet rate to the processor.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 0..65535  

cadSysProcClearPolicingCounts 1.3.6.1.4.1.4998.1.1.5.1.13.35
This variable always returns false(2) upon reading. When set to true(1), all objects under cadSysProcPolicingCounts are cleared.
Status: current Access: read-write
OBJECT-TYPE    
  TruthValue  

cadSysProcLacpPacketRate 1.3.6.1.4.1.4998.1.1.5.1.13.36
The total LACP packet rate to the processor.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 0..65535  

cadSysProcVrepPacketRate 1.3.6.1.4.1.4998.1.1.5.1.13.37
The maximum permitted D6/VREP packet rate to the processor.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 0..65535  

cadSysProcVpmePacketRate 1.3.6.1.4.1.4998.1.1.5.1.13.38
The maximum permitted VPME packet rate to the processor.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 0..65535  

cadSysProcErmRpcPacketRate 1.3.6.1.4.1.4998.1.1.5.1.13.39
The maximum permitted RPC packet rate from an RPC ERM processor.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 0..65535  

cadSysProcRouterControlGlobalPacketsReceivedPassed 1.3.6.1.4.1.4998.1.1.5.1.14.1
The number of packets received passed to the Router Control processor.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cadSysProcRouterControlGlobalPacketsReceivedDropped 1.3.6.1.4.1.4998.1.1.5.1.14.2
The number of packets received that are dropped by the Router Control processor.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cadSysProcArpPacketsReceivedPassed 1.3.6.1.4.1.4998.1.1.5.1.14.4
The number of ARP packets received passed to the processor.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cadSysProcArpPacketsReceivedDropped 1.3.6.1.4.1.4998.1.1.5.1.14.5
The number of ARP packets received that are dropped.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cadSysProcDhcpPacketsReceivedPassed 1.3.6.1.4.1.4998.1.1.5.1.14.7
The number of DHCP packets received passed to the processor.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cadSysProcDhcpPacketsReceivedDropped 1.3.6.1.4.1.4998.1.1.5.1.14.8
The number of DHCP packets received that are dropped.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cadSysProcIcmpPacketsReceivedPassed 1.3.6.1.4.1.4998.1.1.5.1.14.10
The number of ICMP packets received passed to the processor.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cadSysProcIcmpPacketsReceivedDropped 1.3.6.1.4.1.4998.1.1.5.1.14.11
The number of ICMP packets received that are dropped.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cadSysProcOspfPacketsReceivedPassed 1.3.6.1.4.1.4998.1.1.5.1.14.13
The number of OSPFv2 packets received passed to the processor.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cadSysProcOspfPacketsReceivedDropped 1.3.6.1.4.1.4998.1.1.5.1.14.14
The number of OSPFv2 packets received that are dropped.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cadSysProcRipPacketsReceivedPassed 1.3.6.1.4.1.4998.1.1.5.1.14.16
The number of RIP packets received passed to the processor.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cadSysProcRipPacketsReceivedDropped 1.3.6.1.4.1.4998.1.1.5.1.14.17
The number of RIP packets received that are dropped.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cadSysProcIgmpPacketsReceivedPassed 1.3.6.1.4.1.4998.1.1.5.1.14.19
The number of IGMP packets received passed to the processor.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cadSysProcIgmpPacketsReceivedDropped 1.3.6.1.4.1.4998.1.1.5.1.14.20
The number of IGMP packets received that are dropped.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cadSysProcRouterControlOtherPacketsReceivedPassed 1.3.6.1.4.1.4998.1.1.5.1.14.22
The number of other packets received passed to the Router Control processor.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cadSysProcRouterControlOtherPacketsReceivedDropped 1.3.6.1.4.1.4998.1.1.5.1.14.23
The number of other packets received that are dropped by the Router Control processor.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cadSysProcSnmpPacketsReceivedPassed 1.3.6.1.4.1.4998.1.1.5.1.14.25
The number of SNMP packets received passed to the System Control processor.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cadSysProcSnmpPacketsReceivedDropped 1.3.6.1.4.1.4998.1.1.5.1.14.26
The number of SNMP packets received that are dropped.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cadSysProcTftpPacketsReceivedPassed 1.3.6.1.4.1.4998.1.1.5.1.14.28
The number of TFTP packets received passed to the processor.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cadSysProcTftpPacketsReceivedDropped 1.3.6.1.4.1.4998.1.1.5.1.14.29
The number of TFTP packets received that are dropped.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cadSysProcIsisPacketsReceivedPassed 1.3.6.1.4.1.4998.1.1.5.1.14.31
The number of IS-IS packets received passed to the processor.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cadSysProcIsisPacketsReceivedDropped 1.3.6.1.4.1.4998.1.1.5.1.14.32
The number of IS-IS packets received that are dropped.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cadSysProcNdPacketsReceivedPassed 1.3.6.1.4.1.4998.1.1.5.1.14.37
The number of Neighbor Discover packets received passed to the processor.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cadSysProcNdPacketsReceivedDropped 1.3.6.1.4.1.4998.1.1.5.1.14.38
The number of Neighbor Discover packets received that are dropped.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cadSysProcDhcpIpv6PacketsReceivedPassed 1.3.6.1.4.1.4998.1.1.5.1.14.40
The number of DHCP(Ipv6) packets received passed to the processor.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cadSysProcDhcpIpv6PacketsReceivedDropped 1.3.6.1.4.1.4998.1.1.5.1.14.41
The number of DHCP(IPv6) packets received that are dropped.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cadSysProcIcmpIpv6PacketsReceivedPassed 1.3.6.1.4.1.4998.1.1.5.1.14.43
The number of ICMP(Ipv6) packets received passed to the processor.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cadSysProcIcmpIpv6PacketsReceivedDropped 1.3.6.1.4.1.4998.1.1.5.1.14.44
The number of ICMP(IPv6) packets received that are dropped.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cadSysProcMldPacketsReceivedPassed 1.3.6.1.4.1.4998.1.1.5.1.14.46
The number of MLD packets received passed to the processor.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cadSysProcMldPacketsReceivedDropped 1.3.6.1.4.1.4998.1.1.5.1.14.47
The number of MLD packets received that are dropped.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cadSysProcBgpPacketsReceivedPassed 1.3.6.1.4.1.4998.1.1.5.1.14.49
The number of BGP packets received passed to the processor.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cadSysProcBgpPacketsReceivedDropped 1.3.6.1.4.1.4998.1.1.5.1.14.50
The number of BGP packets received that are dropped.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cadSysProcPimPacketsReceivedPassed 1.3.6.1.4.1.4998.1.1.5.1.14.52
The number of PIM packets received passed to the processor.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cadSysProcPimPacketsReceivedDropped 1.3.6.1.4.1.4998.1.1.5.1.14.53
The number of PIM packets received that are dropped.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cadSysProcSnmpCmPacketsReceivedPassed 1.3.6.1.4.1.4998.1.1.5.1.14.55
The number of SNMP (from CMs) packets received passed to the processor.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cadSysProcSnmpCmPacketsReceivedDropped 1.3.6.1.4.1.4998.1.1.5.1.14.56
The number of SNMP (from CMs) packets received that are dropped.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cadSysProcCopsPacketsReceivedPassed 1.3.6.1.4.1.4998.1.1.5.1.14.58
The number of COPS packets received passed to the System Control processor.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cadSysProcCopsPacketsReceivedDropped 1.3.6.1.4.1.4998.1.1.5.1.14.59
The number of COPS packets received that are dropped.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cadSysProcTelnetPacketsReceivedPassed 1.3.6.1.4.1.4998.1.1.5.1.14.61
The number of TELNET packets received passed to the System Control processor.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cadSysProcTelnetPacketsReceivedDropped 1.3.6.1.4.1.4998.1.1.5.1.14.62
The number of TELNET packets received that are dropped.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cadSysProcOspfv3PacketsReceivedPassed 1.3.6.1.4.1.4998.1.1.5.1.14.64
The number of OSPFv3 packets received passed to the processor.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cadSysProcOspfv3PacketsReceivedDropped 1.3.6.1.4.1.4998.1.1.5.1.14.65
The number of OSPFv3 packets received that are dropped.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cadSysProcTftpIpv6PacketsReceivedPassed 1.3.6.1.4.1.4998.1.1.5.1.14.67
The number of TFTP (IPv6) packets received passed to the processor.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cadSysProcTftpIpv6PacketsReceivedDropped 1.3.6.1.4.1.4998.1.1.5.1.14.68
The number of TFTP (IPv6) packets received that are dropped.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cadSysProcLdpPacketsReceivedPassed 1.3.6.1.4.1.4998.1.1.5.1.14.70
The number of LDP (UDP and TCP) packets received passed to the processor.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cadSysProcLdpPacketsReceivedDropped 1.3.6.1.4.1.4998.1.1.5.1.14.71
The number of LDP (UDP and TCP) packets received that are dropped.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cadSysProcEventIcmpPacketsReceivedPassed 1.3.6.1.4.1.4998.1.1.5.1.14.73
The number of ICMP event packets received passed to the processor.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cadSysProcEventIcmpPacketsReceivedDropped 1.3.6.1.4.1.4998.1.1.5.1.14.74
The number of ICMP event packets received that are dropped.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cadSysProcEventNoRoutePacketsReceivedPassed 1.3.6.1.4.1.4998.1.1.5.1.14.75
The number of No Route event packets received passed to the processor.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cadSysProcEventNoRoutePacketsReceivedDropped 1.3.6.1.4.1.4998.1.1.5.1.14.76
The number of No Route event packets received that are dropped.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cadSysProcEventIcmpIpv6PacketsReceivedPassed 1.3.6.1.4.1.4998.1.1.5.1.14.77
The number of ICMP (IPv6) event packets received passed to the processor.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cadSysProcEventIcmpIpv6PacketsReceivedDropped 1.3.6.1.4.1.4998.1.1.5.1.14.78
The number of ICMP (IPv6) event packets received that are dropped.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cadSysProcEventNoRouteIpv6PacketsReceivedPassed 1.3.6.1.4.1.4998.1.1.5.1.14.79
The number of No Route (IPv6) event packets received passed to the processor.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cadSysProcEventNoRouteIpv6PacketsReceivedDropped 1.3.6.1.4.1.4998.1.1.5.1.14.80
The number of No Route (IPv6) event packets received that are dropped.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cadSysProcEventArpPacketsReceivedPassed 1.3.6.1.4.1.4998.1.1.5.1.14.81
The number of ARP event packets received passed to the processor.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cadSysProcEventArpPacketsReceivedDropped 1.3.6.1.4.1.4998.1.1.5.1.14.82
The number of ARP event packets received that are dropped.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cadSysProcEventNdPacketsReceivedPassed 1.3.6.1.4.1.4998.1.1.5.1.14.83
The number of ND event packets received passed to the processor.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cadSysProcEventNdPacketsReceivedDropped 1.3.6.1.4.1.4998.1.1.5.1.14.84
The number of ND event packets received that are dropped.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cadSysProcEventTtlPacketsReceivedPassed 1.3.6.1.4.1.4998.1.1.5.1.14.85
The number of TTL event packets received passed to the processor.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cadSysProcEventTtlPacketsReceivedDropped 1.3.6.1.4.1.4998.1.1.5.1.14.86
The number of TTL event packets received that are dropped.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cadSysProcEventTtlIpv6PacketsReceivedPassed 1.3.6.1.4.1.4998.1.1.5.1.14.87
The number of TTL (IPv6) event packets received passed to the processor.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cadSysProcEventTtlIpv6PacketsReceivedDropped 1.3.6.1.4.1.4998.1.1.5.1.14.88
The number of TTL (IPv6) event packets received that are dropped.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cadSysProcEventDadPacketsReceivedPassed 1.3.6.1.4.1.4998.1.1.5.1.14.89
The number of DAD event packets received passed to the processor.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cadSysProcEventDadPacketsReceivedDropped 1.3.6.1.4.1.4998.1.1.5.1.14.90
The number of DAD event packets received that are dropped.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cadSysProcEventDefaultPacketsReceivedPassed 1.3.6.1.4.1.4998.1.1.5.1.14.91
The number of Default event packets received passed to the processor.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cadSysProcEventDefaultPacketsReceivedDropped 1.3.6.1.4.1.4998.1.1.5.1.14.92
The number of Default event packets received that are dropped.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cadSysProcLacpPacketsReceivedPassed 1.3.6.1.4.1.4998.1.1.5.1.14.93
The number of LACP packets received passed to the processor.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cadSysProcLacpPacketsReceivedDropped 1.3.6.1.4.1.4998.1.1.5.1.14.94
The number of LACP packets received that are dropped.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cadSysProcVrepPacketsReceivedPassed 1.3.6.1.4.1.4998.1.1.5.1.14.95
The number of D6/VREP packets received passed to the processor.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cadSysProcVrepPacketsReceivedDropped 1.3.6.1.4.1.4998.1.1.5.1.14.96
The number of D6/VREP packets received that are dropped.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cadSysProcVpmePacketsReceivedPassed 1.3.6.1.4.1.4998.1.1.5.1.14.97
The number of VPME packets received passed to the processor.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cadSysProcVpmePacketsReceivedDropped 1.3.6.1.4.1.4998.1.1.5.1.14.98
The number of VPME packets received that are dropped.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cadSysProcErmRpcPacketsReceivedPassed 1.3.6.1.4.1.4998.1.1.5.1.14.99
The number of ERM RPC packets received passed to the processor.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cadSysProcErmRpcPacketsReceivedDropped 1.3.6.1.4.1.4998.1.1.5.1.14.100
The number of ERM RPC packets received that are dropped.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

cadSysBannerMotdTable 1.3.6.1.4.1.4998.1.1.5.1.15.1
Table describing the MOTD banner that is displayed before the login: prompt
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    CadSysBannerMotdEntry

cadSysBannerMotdEntry 1.3.6.1.4.1.4998.1.1.5.1.15.1.1
Describes a line in the MOTD banner
Status: current Access: not-accessible
OBJECT-TYPE    
  CadSysBannerMotdEntry  

cadSysBannerMotdLine 1.3.6.1.4.1.4998.1.1.5.1.15.1.1.1
The line number
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 1..100  

cadSysBannerMotdText 1.3.6.1.4.1.4998.1.1.5.1.15.1.1.2
The MOTD banner text
Status: current Access: read-create
OBJECT-TYPE    
  DisplayString Size(0..255)  

cadSysBannerMotdRowStatus 1.3.6.1.4.1.4998.1.1.5.1.15.1.1.3
The row status variable used according to row installation and removal convention. In our case, we have simplified this to the usage of only the following states - active, createAndGo, and destroy. Other three states notInService, notReady and createAndWait are not permitted.
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

cadSysBannerLoginTable 1.3.6.1.4.1.4998.1.1.5.1.15.2
Table describing the login banner that is displayed after the MOTD banner and before the login: prompt
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    CadSysBannerLoginEntry

cadSysBannerLoginEntry 1.3.6.1.4.1.4998.1.1.5.1.15.2.1
Describes a line in the login banner
Status: current Access: not-accessible
OBJECT-TYPE    
  CadSysBannerLoginEntry  

cadSysBannerLoginLine 1.3.6.1.4.1.4998.1.1.5.1.15.2.1.1
The line number
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 1..100  

cadSysBannerLoginText 1.3.6.1.4.1.4998.1.1.5.1.15.2.1.2
The login banner text
Status: current Access: read-create
OBJECT-TYPE    
  DisplayString Size(0..255)  

cadSysBannerLoginRowStatus 1.3.6.1.4.1.4998.1.1.5.1.15.2.1.3
The row status variable used according to row installation and removal convention. In our case, we have simplified this to the usage of only the following states - active, createAndGo, and destroy. Other three states notInService, notReady and createAndWait are not permitted.
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

cadSysBannerExecTable 1.3.6.1.4.1.4998.1.1.5.1.15.3
Tok_String
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    CadSysBannerExecEntry

cadSysBannerExecEntry 1.3.6.1.4.1.4998.1.1.5.1.15.3.1
Tok_String
Status: current Access: not-accessible
OBJECT-TYPE    
  CadSysBannerExecEntry  

cadSysBannerExecLine 1.3.6.1.4.1.4998.1.1.5.1.15.3.1.1
Index of this banner line.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 1..25  

cadSysBannerExecText 1.3.6.1.4.1.4998.1.1.5.1.15.3.1.2
Ascii text of this banner line.
Status: current Access: read-create
OBJECT-TYPE    
  DisplayString Size(0..255)  

cadSysBannerExecRowStatus 1.3.6.1.4.1.4998.1.1.5.1.15.3.1.3
The row status variable used according to row installation and removal convention. In our case, we have simplified this to the usage of only the following states - active, createAndGo, and destroy. Other three states notInService, notReady and createAndWait are not permitted.
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

cadSysBannerIncomingTable 1.3.6.1.4.1.4998.1.1.5.1.15.4
Tok_String
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    CadSysBannerIncomingEntry

cadSysBannerIncomingEntry 1.3.6.1.4.1.4998.1.1.5.1.15.4.1
Tok_String
Status: current Access: not-accessible
OBJECT-TYPE    
  CadSysBannerIncomingEntry  

cadSysBannerIncomingLine 1.3.6.1.4.1.4998.1.1.5.1.15.4.1.1
Tok_String
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 1..25  

cadSysBannerIncomingText 1.3.6.1.4.1.4998.1.1.5.1.15.4.1.2
Tok_String
Status: current Access: read-create
OBJECT-TYPE    
  DisplayString Size(0..255)  

cadSysBannerIncomingRowStatus 1.3.6.1.4.1.4998.1.1.5.1.15.4.1.3
The row status variable used according to row installation and removal convention. In our case, we have simplified this to the usage of only the following states - active, createAndGo, and destroy. Other three states notInService, notReady and createAndWait are not permitted.
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

cadSysServerTable 1.3.6.1.4.1.4998.1.1.5.1.16.1
Table describing the (INET) services that should run on the SCM.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    CadSysServerEntry

cadSysServerEntry 1.3.6.1.4.1.4998.1.1.5.1.16.1.1
Describes an INET service and whether it is enabled
Status: current Access: not-accessible
OBJECT-TYPE    
  CadSysServerEntry  

cadSysServerType 1.3.6.1.4.1.4998.1.1.5.1.16.1.1.1
The service type
Status: current Access: not-accessible
OBJECT-TYPE    
  ServerType  

cadSysServerAdminState 1.3.6.1.4.1.4998.1.1.5.1.16.1.1.2
The administrative state of the server.
Status: current Access: read-create
OBJECT-TYPE    
  AdminState  

cadSysPatchParamTable 1.3.6.1.4.1.4998.1.1.5.1.17.1
Table of patch parameters.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    CadSysPatchParamEntry

cadSysPatchParamEntry 1.3.6.1.4.1.4998.1.1.5.1.17.1.1
Entry of an individual patch parameter.
Status: current Access: not-accessible
OBJECT-TYPE    
  CadSysPatchParamEntry  

cadSysPatchParamIndex 1.3.6.1.4.1.4998.1.1.5.1.17.1.1.1
The patch parameter index.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 1..1000  

cadSysPatchParamName 1.3.6.1.4.1.4998.1.1.5.1.17.1.1.2
The patch parameter name.
Status: current Access: read-create
OBJECT-TYPE    
  DisplayString Size(0..64)  

cadSysPatchParamValue 1.3.6.1.4.1.4998.1.1.5.1.17.1.1.3
The patch parameter value.
Status: current Access: read-create
OBJECT-TYPE    
  DisplayString Size(0..64)  

cadSysPatchParamDescription 1.3.6.1.4.1.4998.1.1.5.1.17.1.1.4
The patch parameter description.
Status: current Access: read-create
OBJECT-TYPE    
  DisplayString Size(0..64)  

cadSysPatchParamRowStatus 1.3.6.1.4.1.4998.1.1.5.1.17.1.1.5
The row status variable used according to row installation and removal convention. In our case, we have simplified this to the usage of only the following states - active, createAndGo, and destroy. Other three states notInService, notReady and createAndWait are not permitted.
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

cadSysMtceStatusCloneMonitorThreshold 1.3.6.1.4.1.4998.1.1.5.1.19.8
Timeout during normal operation.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 2750..6250  

cadSysMtceStatusCloneInitThreshold 1.3.6.1.4.1.4998.1.1.5.1.19.9
Timeout on initialization for first status message.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 3000..9000  

cadSysMtceStatusCloneRcvyThreshold 1.3.6.1.4.1.4998.1.1.5.1.19.10
Timeout following clone side recovery.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 120000..360000  

cadSysMtceBasePingRate 1.3.6.1.4.1.4998.1.1.5.1.19.11
Interval between system maintenance polling of monitored threads.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 750..2250  

cadSysMtceOvSensitivity 1.3.6.1.4.1.4998.1.1.5.1.19.12
Defines the sensitivity of user overload to changes in internal work load. Higher sensitivity results in more rapid change of user overload in response to a change in the internal work load.
Status: current Access: read-write
OBJECT-TYPE    
  OverloadThreshold  

cadSysMtceOvThreshold 1.3.6.1.4.1.4998.1.1.5.1.19.13
Defines the overall threshold of user overload transitions. Higher thresholds require a longer time in an internal overload state before user overload transitions occur.
Status: current Access: read-write
OBJECT-TYPE    
  OverloadThreshold  

cadSysMtceDULPacketInterval 1.3.6.1.4.1.4998.1.1.5.1.19.14
Interval between maintenance polling of monitored BroadCom devices. Setting the value to zero will disable BroadCom device monitoring.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 0 | 10000..900000  

cadSysDataServerDataTimeout 1.3.6.1.4.1.4998.1.1.5.1.21.1
Time allowed for Data Query/Update to be processed.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 50000..500000  

cadSysDataServerDataEventsPerCycle 1.3.6.1.4.1.4998.1.1.5.1.21.2
Number of data events allowed per cycle.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 10..200  

cadSysDataServerDataSyncTimeout 1.3.6.1.4.1.4998.1.1.5.1.21.3
Number of data events allowed per cycle.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 8000..100000  

cadSysDataServerSnmpReadAheadEnable 1.3.6.1.4.1.4998.1.1.5.1.21.4
When this value is set to true Snmp read ahead is performed.
Status: current Access: read-write
OBJECT-TYPE    
  TruthValue  

cadSysDataServerSnmpReadAheadMax 1.3.6.1.4.1.4998.1.1.5.1.21.5
This value is the maximum number of records to read ahead
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 0..20  

cadSysDataServerSnmpRefreshTime 1.3.6.1.4.1.4998.1.1.5.1.21.6
This value represents how old a database record can be to be used.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 1..1200  

cadSysDataServerSyncDataEventsPerCycle 1.3.6.1.4.1.4998.1.1.5.1.21.7
This value is the maximum number of Sync events that will be processed per cycle.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 40..100  

cadSysDataServerLoPriDataEventsPerCycle 1.3.6.1.4.1.4998.1.1.5.1.21.8
This value is the maximum number of Low Priority Sync events to be processed per cycle.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 10..100  

cadSysSourceAddressTable 1.3.6.1.4.1.4998.1.1.5.1.22.1
Table of source interface addresses for administrative services
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    CadSysSourceAddressEntry

cadSysSourceAddressEntry 1.3.6.1.4.1.4998.1.1.5.1.22.1.1
This entry contains the configured source IPv4 and/or IPv6 address for each administrative service. If configured, it also contains the global default address.
Status: current Access: not-accessible
OBJECT-TYPE    
  CadSysSourceAddressEntry  

cadSysSourceAddressIndex 1.3.6.1.4.1.4998.1.1.5.1.22.1.1.1
The type of administrative service.
Status: current Access: not-accessible
OBJECT-TYPE    
  AdminSrcAddrType  

cadSysSourceInterfaceIpv4IfIndex 1.3.6.1.4.1.4998.1.1.5.1.22.1.1.2
The ifIndex of the interface from which all IPv4 packets are sourced. For a server service, it is also the only DIP allowed for incoming requests. A value of 0 indicates no source interface override.
Status: current Access: read-write
OBJECT-TYPE    
  InterfaceIndexOrZero  

cadSysSourceAddressIpv4Address 1.3.6.1.4.1.4998.1.1.5.1.22.1.1.3
The IPv4 address of the IPv4 interface at the time the row ipv4 ifIndex was populated. Used as the source address for the service if the state is in-service. For a server service, it is also the only DIP allowed for incoming requests. A value of null indicates no source address has been assigned.
Status: current Access: read-only
OBJECT-TYPE    
  InetAddressIPv4  

cadSysSourceInterfaceIpv6IfIndex 1.3.6.1.4.1.4998.1.1.5.1.22.1.1.4
The ifIndex of the interface from which all IPv6 packets are sourced (not currently supported). For a server service, it is also the only DIP allowed for incoming requests. A value of 0 indicates no source interface override.
Status: current Access: read-write
OBJECT-TYPE    
  InterfaceIndexOrZero  

cadSysSourceAddressIpv6Address 1.3.6.1.4.1.4998.1.1.5.1.22.1.1.5
The IPv6 address of the IPv6 interface at the time the ipv6 ifIndex was populated. Used as the source address for the service if the state is in-service. For a server service, it is also the only DIP allowed for incoming requests. A value of null indicates no source address has been assigned.
Status: current Access: read-only
OBJECT-TYPE    
  InetAddressIPv6  

cadSysLicenseCardId 1.3.6.1.4.1.4998.1.1.5.1.23.1
CAM to be licensed.
Status: current Access: not-accessible
OBJECT-TYPE    
  CardId  

cadSysLicenseKey 1.3.6.1.4.1.4998.1.1.5.1.23.2
License key to apply to the CAM.
Status: current Access: not-accessible
OBJECT-TYPE    
  OCTET STRING Size(16)  

cadSysLicensePorts 1.3.6.1.4.1.4998.1.1.5.1.23.3
Number of CAM ports associated with the license.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 0..5000  

cadSysLicenseAnnex 1.3.6.1.4.1.4998.1.1.5.1.23.4
This attribute defines the ITU-J-83 Annex being used for this E6000 CMTS License.
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER unknown(1), other(2), annexA(3), annexB(4), annexC(5)  

cadSysLicenseStatus 1.3.6.1.4.1.4998.1.1.5.1.23.5
Current status of licensing operation.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER success(1), fail(2), pending(3), none(4)  

cadLaesMdTimestampModeTable 1.3.6.1.4.1.4998.1.1.5.1.24.1
Table of LAES Mediation Device Timestamp mode table
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    CadLaesMdTimestampModeEntry

cadLaesMdTimestampModeEntry 1.3.6.1.4.1.4998.1.1.5.1.24.1.1
This entry contains the configured MD IPv4. If configured, then all encapsulated tap packets going to that MD will contain a timestamp in the tap header.
Status: current Access: not-accessible
OBJECT-TYPE    
  CadLaesMdTimestampModeEntry  

cadLaesMdTimestampModeInetAddrType 1.3.6.1.4.1.4998.1.1.5.1.24.1.1.1
The IP Address type of Mediation Device
Status: current Access: not-accessible
OBJECT-TYPE    
  InetAddressType  

cadLaesMdTimestampModeInetAddr 1.3.6.1.4.1.4998.1.1.5.1.24.1.1.2
The IP Address of the Mediation Device.
Status: current Access: not-accessible
OBJECT-TYPE    
  InetAddress  

cadLaesMdTimestampModRowStatus 1.3.6.1.4.1.4998.1.1.5.1.24.1.1.3
The row status of this entry
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

cadSysMICSecondarySecretTable 1.3.6.1.4.1.4998.1.1.5.1.25.1
Table containing secondary shared secret strings for cable modem configuration file authentication. This table is not used unless cadSysMICEnable is set to true.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    CadSysMICSecondarySecretEntry

cadSysMICSecondarySecretEntry 1.3.6.1.4.1.4998.1.1.5.1.25.1.1
Entry containing secondary shared secret strings for cable modem configuration file authentication.
Status: current Access: not-accessible
OBJECT-TYPE    
  CadSysMICSecondarySecretEntry  

cadSysMICSecondarySecretIndex 1.3.6.1.4.1.4998.1.1.5.1.25.1.1.1
Internal index for this MIB row.
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 1..1  

cadSysMICSecondarySecretString 1.3.6.1.4.1.4998.1.1.5.1.25.1.1.2
Encrypted MIC Authentication shared secret string.
Status: current Access: read-create
OBJECT-TYPE    
  OCTET STRING Size(0..64)  

cadSysMICSecondarySecretStatus 1.3.6.1.4.1.4998.1.1.5.1.25.1.1.3
The status of this conceptual row.
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

cadSystemMibConformance 1.3.6.1.4.1.4998.1.1.5.1.12
OBJECT IDENTIFIER    

cadSystemCompliances 1.3.6.1.4.1.4998.1.1.5.1.12.1
OBJECT IDENTIFIER    

cadSystemGroups 1.3.6.1.4.1.4998.1.1.5.1.12.2
OBJECT IDENTIFIER    

cadSystemCompliance 1.3.6.1.4.1.4998.1.1.5.1.12.1.1
Compliance statement for entities implementing the Cadant System Mib.
Status: current Access: read-create
MODULE-COMPLIANCE    

cadSysParamsGroup 1.3.6.1.4.1.4998.1.1.5.1.12.2.1
System parameter objects
Status: current Access: read-create
OBJECT-GROUP    

cadSysSystemGroup 1.3.6.1.4.1.4998.1.1.5.1.12.2.2
System description objects
Status: current Access: read-create
OBJECT-GROUP    

cadSysControlGroup 1.3.6.1.4.1.4998.1.1.5.1.12.2.3
System control objects
Status: deprecated Access: read-create
OBJECT-GROUP    

cadSysSnmpGroup 1.3.6.1.4.1.4998.1.1.5.1.12.2.4
System snmp control object
Status: current Access: read-create
OBJECT-GROUP    

cadSysBootParamsGroup 1.3.6.1.4.1.4998.1.1.5.1.12.2.5
System boot parameters objects
Status: current Access: read-create
OBJECT-GROUP    

cadSysReloadGroup 1.3.6.1.4.1.4998.1.1.5.1.12.2.6
System reload control objects
Status: current Access: read-create
OBJECT-GROUP    

cadSysImageGroup 1.3.6.1.4.1.4998.1.1.5.1.12.2.7
System image status objects
Status: current Access: read-create
OBJECT-GROUP    

cadSysConfigurationGroup 1.3.6.1.4.1.4998.1.1.5.1.12.2.8
Configuration objects
Status: current Access: read-create
OBJECT-GROUP    

cadSysDataServerGroup 1.3.6.1.4.1.4998.1.1.5.1.12.2.9
Configuration objects
Status: current Access: read-create
OBJECT-GROUP    

cadSysSourceAddressGroup 1.3.6.1.4.1.4998.1.1.5.1.12.2.10
Source Interface objects.
Status: current Access: read-create
OBJECT-GROUP