CADANT-CMTS-PROCESS-MIB

File: CADANT-CMTS-PROCESS-MIB.mib (10008 bytes)

Imported modules

SNMPv2-SMI SNMPv2-TC SNMPv2-CONF
CADANT-PRODUCTS-MIB CADANT-CMTS-EQUIPMENT-MIB CADANT-TC

Imported symbols

OBJECT-TYPE MODULE-IDENTITY NOTIFICATION-TYPE
Integer32 Counter32 Unsigned32
Counter64 DisplayString TEXTUAL-CONVENTION
RowStatus TimeInterval TruthValue
OBJECT-GROUP MODULE-COMPLIANCE cadSystem
trapCounter trapSeverity cardNumber
CardId OverloadStatus

Defined Types

CadCpuEntry  
SEQUENCE    
  cadCpuCardId CardId
  cadCpuRecentTime Counter64
  cadCpuTotalTime Counter64
  cadIdleCpuRecentTime Counter64
  cadIdleCpuTotalTime Counter64
  cadSwitchRecentCount Counter64
  cadSwitchTotalCount Counter64
  cadIdleCpuRecentPercent Integer32

CadMemoryEntry  
SEQUENCE    
  cadMeCardId CardId
  cadMeHeapSize Unsigned32
  cadMeHeapRemaining Unsigned32

CadOverloadEntry  
SEQUENCE    
  cadOvCardId CardId
  cadOvCpuStatus OverloadStatus
  cadOvMemStatus OverloadStatus

Defined Values

cadProcessMib 1.3.6.1.4.1.4998.1.1.5.3
This MIB module contains information on the process table and memory usage of the C4.
MODULE-IDENTITY    

cadProcessTraps 1.3.6.1.4.1.4998.1.1.5.3.0
OBJECT IDENTIFIER    

cadProcessGroup 1.3.6.1.4.1.4998.1.1.5.3.1
OBJECT IDENTIFIER    

cadCpu 1.3.6.1.4.1.4998.1.1.5.3.1.1
A conceptual row containing information about the cpu and system statistics.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    CadCpuEntry

cadCpuEntry 1.3.6.1.4.1.4998.1.1.5.3.1.1.1
A conceptual row containing information about the cpu and system statistics.
Status: current Access: not-accessible
OBJECT-TYPE    
  CadCpuEntry  

cadCpuCardId 1.3.6.1.4.1.4998.1.1.5.3.1.1.1.1
Index of slot
Status: current Access: not-accessible
OBJECT-TYPE    
  CardId  

cadCpuRecentTime 1.3.6.1.4.1.4998.1.1.5.3.1.1.1.2
Total CPU time consumed in the last reporting cycle.
Status: current Access: read-only
OBJECT-TYPE    
  Counter64  

cadCpuTotalTime 1.3.6.1.4.1.4998.1.1.5.3.1.1.1.3
Total CPU time consumed since the card was initialized.
Status: current Access: read-only
OBJECT-TYPE    
  Counter64  

cadIdleCpuRecentTime 1.3.6.1.4.1.4998.1.1.5.3.1.1.1.4
CPU time consumed by non-critical tasks in the last reporting cycle.
Status: current Access: read-only
OBJECT-TYPE    
  Counter64  

cadIdleCpuTotalTime 1.3.6.1.4.1.4998.1.1.5.3.1.1.1.5
CPU time consumed by non-critical tasks since the card was initialized.
Status: current Access: read-only
OBJECT-TYPE    
  Counter64  

cadSwitchRecentCount 1.3.6.1.4.1.4998.1.1.5.3.1.1.1.6
Number of task switches in the last reporting cycle.
Status: current Access: read-only
OBJECT-TYPE    
  Counter64  

cadSwitchTotalCount 1.3.6.1.4.1.4998.1.1.5.3.1.1.1.7
Number of task switches since the card was initialized.
Status: current Access: read-only
OBJECT-TYPE    
  Counter64  

cadIdleCpuRecentPercent 1.3.6.1.4.1.4998.1.1.5.3.1.1.1.8
Percentage of idle CPU time in last reporting cycle.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..100  

cadMemoryGroup 1.3.6.1.4.1.4998.1.1.5.3.2
OBJECT IDENTIFIER    

cadMemory 1.3.6.1.4.1.4998.1.1.5.3.2.1
A table that contains information on the memory present on the C4 line cards.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    CadMemoryEntry

cadMemoryEntry 1.3.6.1.4.1.4998.1.1.5.3.2.1.1
A conceptual row containing information about processes and their configuration and operating parameters.
Status: current Access: not-accessible
OBJECT-TYPE    
  CadMemoryEntry  

cadMeCardId 1.3.6.1.4.1.4998.1.1.5.3.2.1.1.1
Index of slot
Status: current Access: not-accessible
OBJECT-TYPE    
  CardId  

cadMeHeapSize 1.3.6.1.4.1.4998.1.1.5.3.2.1.1.2
Total size of the dynamic heap.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

cadMeHeapRemaining 1.3.6.1.4.1.4998.1.1.5.3.2.1.1.3
Size of the dynamic currently unallocated.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

cadOverloadGroup 1.3.6.1.4.1.4998.1.1.5.3.3
OBJECT IDENTIFIER    

cadOverload 1.3.6.1.4.1.4998.1.1.5.3.3.1
A table that contains information on the overload status of the C4 line cards.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    CadOverloadEntry

cadOverloadEntry 1.3.6.1.4.1.4998.1.1.5.3.3.1.1
A conceptual row containing information about processes and their configuration and operating parameters.
Status: current Access: not-accessible
OBJECT-TYPE    
  CadOverloadEntry  

cadOvCardId 1.3.6.1.4.1.4998.1.1.5.3.3.1.1.1
Slot number of card
Status: current Access: not-accessible
OBJECT-TYPE    
  CardId  

cadOvCpuStatus 1.3.6.1.4.1.4998.1.1.5.3.3.1.1.2
Overload status of card
Status: current Access: read-only
OBJECT-TYPE    
  OverloadStatus  

cadOvMemStatus 1.3.6.1.4.1.4998.1.1.5.3.3.1.1.3
Memory Overload status of card
Status: deprecated Access: read-only
OBJECT-TYPE    
  OverloadStatus  

cadOvSysCpuStatus 1.3.6.1.4.1.4998.1.1.5.3.3.2
Overload status of E6
Status: current Access: read-only
OBJECT-TYPE    
  OverloadStatus  

cadOvSysMemStatus 1.3.6.1.4.1.4998.1.1.5.3.3.3
Memory Overload status of card
Status: current Access: read-only
OBJECT-TYPE    
  OverloadStatus  

cadProcessTrapInfo 1.3.6.1.4.1.4998.1.1.5.3.4
OBJECT IDENTIFIER    

cadProcessOverloadStatus 1.3.6.1.4.1.4998.1.1.5.3.4.1
Overload status of C4
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  OverloadStatus  

cardOverloadNotification 1.3.6.1.4.1.4998.1.1.5.3.0.1
This trap is sent when the card changes overload state (controlled by cardTrapInh).
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

sysOverloadNotification 1.3.6.1.4.1.4998.1.1.5.3.0.2
This trap is sent when the system changes overload state.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

cadProcessMibConformance 1.3.6.1.4.1.4998.1.1.5.3.5
OBJECT IDENTIFIER    

cadProcessCompliances 1.3.6.1.4.1.4998.1.1.5.3.5.1
OBJECT IDENTIFIER    

cadProcessGroups 1.3.6.1.4.1.4998.1.1.5.3.5.2
OBJECT IDENTIFIER    

cadProcessCompliance 1.3.6.1.4.1.4998.1.1.5.3.5.1.1
Compliance statement for entities implementing the Cadant Process Mib.
Status: current Access: accessible-for-notify
MODULE-COMPLIANCE