Baytech-MIB-401-4

File: Baytech-MIB-401-4.mib (76366 bytes)

Imported modules

RFC1155-SMI RFC1213-MIB RFC-1212
RFC-1215

Imported symbols

enterprises IpAddress Gauge
TimeTicks DisplayString OBJECT-TYPE
TRAP-TYPE

Defined Types

SDSNetworkConfigSNMPTrapReceiverEntry  
SEQUENCE    
  trapIndex INTEGER
  receiverAddress IpAddress

SDSModulesRPCEntry  
SEQUENCE    
  sBTAModulesRPCIndex INTEGER
  sBTAModulesRPCName DisplayString
  sBTAModulesRPCFirmwareVersion DisplayString
  sBTAModulesRPCCurrent INTEGER
  sBTAModulesRPCMaxCurrent INTEGER
  sBTAModulesRPCVoltage INTEGER
  sBTAModulesRPCPower INTEGER
  sBTAModulesRPCTemperature INTEGER
  sBTAModulesRPCRebootTimeout INTEGER
  sBTAModulesRPCAllOutletsCmd INTEGER
  sBTAModulesRPCAllOutletsStatus DisplayString
  sBTAModulesRPCCurrentAlarmThreshold INTEGER
  sBTAModulesRPCOverVoltageThreshold INTEGER
  sBTAModulesRPCUnderVoltageThreshold INTEGER
  sBTAModulesRPCNumberOfOutlets INTEGER
  sBTAModulesRPCCircuitBreaker INTEGER
  sBTAModulesRPCOverTempThreshold INTEGER
  sBTAModulesRPCUnitVA INTEGER
  sBTAModulesRPCNumberOfBreakers INTEGER
  sBTAModulesRPCLowCurrentThreshold INTEGER
  sBTAModulesRPCVoltageSource INTEGER
  sBTAModulesRPCSourceSwitchCount INTEGER
  sBTAModulesRPCNumberOfSensors INTEGER
  sBTAModulesRPCType DisplayString

SDSModulesRPCOutletEntry  
SEQUENCE    
  sBTAModulesRPCOutletModuleIndex INTEGER
  sBTAModulesRPCOutletIndex INTEGER
  sBTAModulesRPCOutletState INTEGER
  sBTAModulesRPCOutletName DisplayString

SDSModulesRPCCurrentGroupsCurrentEntry  
SEQUENCE    
  groupCurrentIndex INTEGER
  groupCurrent INTEGER
  rpcGroup DisplayString
  warningThreshold INTEGER
  emergencyThreshold INTEGER

SDSModulesRPCBreakersEntry  
SEQUENCE    
  sBTAModulesRPCBreakersModulesIndex INTEGER
  sBTAModulesRPCBreakersBreakersIndex INTEGER
  sBTAModulesRPCBreakersCircuitBreaker INTEGER
  sBTAModulesRPCBreakersCurrent INTEGER
  sBTAModulesRPCBreakersMaxCurrent INTEGER
  sBTAModulesRPCBreakersVoltage INTEGER
  sBTAModulesRPCBreakersPower INTEGER
  sBTAModulesRPCBreakersVA INTEGER
  sBTAModulesRPCBreakersCurrentAlarmThreshold INTEGER

SDSControlUserEntry  
SEQUENCE    
  sBTAControlUserIndex INTEGER
  sBTAControlUserName DisplayString
  sBTAControlUserAddress IpAddress
  sBTAControlUserConnection INTEGER
  sBTAControlUserConnModule INTEGER
  sBTAControlUserConnPort INTEGER
  sBTAControlUserTerminateUser INTEGER

SDSModulesRPCModPortEntry  
SEQUENCE    
  sRPCModuleIndex INTEGER
  sRPCPortIndex INTEGER
  sRPCType DisplayString
  sRPCName DisplayString
  sRPCFirmwareVersion DisplayString
  sRPCCurrent INTEGER
  sRPCMaxCurrent INTEGER
  sRPCVoltage INTEGER
  sRPCPower INTEGER
  sRPCTemperature INTEGER
  sRPCRebootTimeout INTEGER
  sRPCAllOutletsCmd INTEGER
  sRPCAllOutletsStatus DisplayString
  sRPCCurrentAlarmThreshold INTEGER
  sRPCOverVoltageThreshold INTEGER
  sRPCUnderVoltageThreshold INTEGER
  sRPCNumberOfOutlets INTEGER
  sRPCCircuitBreaker INTEGER
  sRPCOverTempThreshold INTEGER
  sRPCUnitVA INTEGER
  sRPCNumberOfBreakers INTEGER
  sRPCLowCurrentThreshold INTEGER
  sRPCVoltageSource INTEGER
  sRPCSourceSwitchCount INTEGER
  sRPCNumberOfSensors INTEGER

SDSModulesRPCModPortOutletEntry  
SEQUENCE    
  sRPCOutletModuleIndex INTEGER
  sRPCOutletPortIndex INTEGER
  sRPCOutletIndex INTEGER
  sRPCOutletState INTEGER
  sRPCOutletName DisplayString

SRPCModPortBreakersEntry  
SEQUENCE    
  sRPCBreakersModIndex INTEGER
  sRPCBreakersPortIndex INTEGER
  sRPCBreakersBreakersIndex INTEGER
  sRPCBreakersCircuitBreaker INTEGER
  sRPCBreakersCurrent INTEGER
  sRPCBreakersMaxCurrent INTEGER
  sRPCBreakersVoltage INTEGER
  sRPCBreakersPower INTEGER
  sRPCBreakersVA INTEGER
  sRPCBreakersCurrentAlarmThreshold INTEGER

SDSModulesEnvironmentalObjectsEntry  
SEQUENCE    
  sBTAModulesEnvironmentalModulesIndex INTEGER
  sBTAModulesEnvironmentalSensorsIndex INTEGER
  sBTAModulesEnvironmentalType INTEGER
  sBTAModulesEnvironmentalName DisplayString
  sBTAModulesEnvironmentalMeasurement INTEGER
  sBTAModulesEnvironmentalHiThreshold INTEGER
  sBTAModulesEnvironmentalLoThreshold INTEGER
  sBTAModulesEnvironmentalMax INTEGER
  sBTAModulesEnvironmentalMin INTEGER
  sBTAModulesEnvironmentalHiThresholdEn INTEGER
  sBTAModulesEnvironmentalLoThresholdEn INTEGER
  sBTAModulesEnvironmentalStateTrapEn INTEGER

SRPCEnvironmentalObjectsEntry  
SEQUENCE    
  sRPCEnvironmentalModuleIndex INTEGER
  sRPCEnvironmentalPortIndex INTEGER
  sRPCEnvironmentalSensorsIndex INTEGER
  sRPCEnvironmentalType INTEGER
  sRPCEnvironmentalName DisplayString
  sRPCEnvironmentalMeasurement INTEGER
  sRPCEnvironmentalHiThreshold INTEGER
  sRPCEnvironmentalLoThreshold INTEGER
  sRPCEnvironmentalMax INTEGER
  sRPCEnvironmentalMin INTEGER
  sRPCEnvironmentalHiThresholdEn INTEGER
  sRPCEnvironmentalLoThresholdEn INTEGER
  sRPCEnvironmentalStateTrapEn INTEGER

Defined Values

baytech 1.3.6.1.4.1.4779
OBJECT IDENTIFIER    

btadevices 1.3.6.1.4.1.4779.1
OBJECT IDENTIFIER    

mtrapargs 1.3.6.1.4.1.4779.3
OBJECT IDENTIFIER    

sBTAIdent 1.3.6.1.4.1.4779.1.1
OBJECT IDENTIFIER    

sBTANetworkConfig 1.3.6.1.4.1.4779.1.2
OBJECT IDENTIFIER    

sBTAModules 1.3.6.1.4.1.4779.1.3
OBJECT IDENTIFIER    

sBTAControl 1.3.6.1.4.1.4779.1.4
OBJECT IDENTIFIER    

sBTAFileTransfer 1.3.6.1.4.1.4779.1.5
OBJECT IDENTIFIER    

sBTAEnvironmental 1.3.6.1.4.1.4779.1.6
OBJECT IDENTIFIER    

sBTAIdentFirmwareRev 1.3.6.1.4.1.4779.1.1.1
An 8 byte ID string identifying the DS72 firmware revision. This value is set at the factory.
OBJECT-TYPE    
  DisplayString  

sBTAIdentSerialNumber 1.3.6.1.4.1.4779.1.1.2
A number identifying the serial number of the DS72. This value is set at the factory.
OBJECT-TYPE    
  INTEGER  

sBTAIdentUnitName 1.3.6.1.4.1.4779.1.1.3
A 64-character string identifying the name (UnitID) of the DS72. This value is set at the factory to a default of DS72.
OBJECT-TYPE    
  DisplayString Size(64)  

sBTANetworkConfigBootpEnable 1.3.6.1.4.1.4779.1.2.1
Enables/disables bootp. Bootp will not take effect until the unit is reseted.
OBJECT-TYPE    
  INTEGER disabled(0), enabled(1)  

sBTANetworkConfigDHCPEnable 1.3.6.1.4.1.4779.1.2.2
Enables/disables DHCP. DHCP will not take effect until the unit is reseted.
OBJECT-TYPE    
  INTEGER disabled(0), enabled(1)  

sBTANetworkConfigSSHEnable 1.3.6.1.4.1.4779.1.2.3
Enables/disables SSH logins. Disable/enable SSH will take effect after the unit is reseted.
OBJECT-TYPE    
  INTEGER disabled(0), enabled(1)  

sBTANetworkConfigTelnetEnable 1.3.6.1.4.1.4779.1.2.4
Enables/disables telnet.
OBJECT-TYPE    
  INTEGER disabled(0), enabled(1)  

sBTANetworkConfigActivityTimeout 1.3.6.1.4.1.4779.1.2.5
A value from 0 to 120. 0 disables activity timeouts. Value represents minutes of non-activity before telnet / SSH sessions are automatically logged out. Default is 0.
OBJECT-TYPE    
  INTEGER  

sBTANetworkConfigDirectConnEnable 1.3.6.1.4.1.4779.1.2.6
Enables/disables direct port connection upon login.
OBJECT-TYPE    
  INTEGER disabled(0), enabled(1)  

sBTANetworkConfigSNMP 1.3.6.1.4.1.4779.1.2.8
OBJECT IDENTIFIER    

sBTANetworkConfigRadius 1.3.6.1.4.1.4779.1.2.9
OBJECT IDENTIFIER    

sBTANetworkConfigWEB 1.3.6.1.4.1.4779.1.2.10
OBJECT IDENTIFIER    

sBTANetworkConfigSNMPReadOnlyCommunity 1.3.6.1.4.1.4779.1.2.8.1
The community name to use for read only access. Maximum len 16 bytes.
OBJECT-TYPE    
  DisplayString  

sBTANetworkConfigSNMPReadWriteCommunity 1.3.6.1.4.1.4779.1.2.8.2
The community name to use for read-write access. Maximum len 16 bytes.
OBJECT-TYPE    
  DisplayString  

sBTANetworkConfigSNMPNumTrapReceivers 1.3.6.1.4.1.4779.1.2.8.3
The maximum number of managers to send traps to. Currently 4.
OBJECT-TYPE    
  INTEGER  

sBTANetworkConfigSNMPTrapReceiverTable 1.3.6.1.4.1.4779.1.2.8.4
A list of managers to send traps to. The number of entries is given by the value of sBTANetworkConfigSNMPNumTrapReceivers. Maximum number of Trap Receivers is four.
OBJECT-TYPE    
  SEQUENCE OF  
    SDSNetworkConfigSNMPTrapReceiverEntry

sBTANetworkConfigSNMPTrapReceiverEntry 1.3.6.1.4.1.4779.1.2.8.4.1
Table of managers to send traps to.
OBJECT-TYPE    
  SDSNetworkConfigSNMPTrapReceiverEntry  

trapIndex 1.3.6.1.4.1.4779.1.2.8.4.1.1
The index to a trap receiver entry.
OBJECT-TYPE    
  INTEGER  

receiverAddress 1.3.6.1.4.1.4779.1.2.8.4.1.2
The IP address of the manager to send traps to.
OBJECT-TYPE    
  IpAddress  

sBTANetworkConfigRadiusEnable 1.3.6.1.4.1.4779.1.2.9.1
Enables / disables RADIUS telnet logins.
OBJECT-TYPE    
  INTEGER disable(0), enable(1)  

sBTANetworkConfigRadiusPrimaryServer 1.3.6.1.4.1.4779.1.2.9.2
Ip address of the primary RADIUS server.
OBJECT-TYPE    
  IpAddress  

sBTANetworkConfigRadiusSecondaryServer 1.3.6.1.4.1.4779.1.2.9.3
Ip address of the back-up RADIUS server.
OBJECT-TYPE    
  IpAddress  

sBTANetworkConfigRadiusLocalLogin 1.3.6.1.4.1.4779.1.2.9.4
Enables / disables the use of local (usernames stored in the DS72) logins in the case that both the primary and secondary RADIUS server are not available.
OBJECT-TYPE    
  INTEGER disable(0), enable(1)  

sBTANetworkConfigWebEnable 1.3.6.1.4.1.4779.1.2.10.1
Enables WEB.
OBJECT-TYPE    
  INTEGER disabled(0), enabled(1)  

sBTANetworkConfigWebSecureEnable 1.3.6.1.4.1.4779.1.2.10.2
Enables WEB Security.
OBJECT-TYPE    
  INTEGER disabled(0), enabled(1)  

sBTANetworkConfigWebLoginEnable 1.3.6.1.4.1.4779.1.2.10.3
Enables WEB Login.
OBJECT-TYPE    
  INTEGER disabled(0), enabled(1)  

sBTANetworkConfigWebActivityTimeout 1.3.6.1.4.1.4779.1.2.10.4
A value from 0 to 120. 0 disables WEB activity timeouts. Value represents minutes of non-activity before WEB sessions are automatically logged out. Default is 0.
OBJECT-TYPE    
  INTEGER  

sBTAModulesNumberOfModules 1.3.6.1.4.1.4779.1.3.1
Number of modules installed into the DS unit.
OBJECT-TYPE    
  INTEGER  

sBTAModulesModulesInstalled 1.3.6.1.4.1.4779.1.3.2
A character string listing the modules installed seperated by commas. Each module is identifed by a two digit number indicating the slot. For example 02,03,04,06 means modules 2,3,4 and 6 are installed.
OBJECT-TYPE    
  DisplayString  

sBTAModulesResetModulesCmd 1.3.6.1.4.1.4779.1.3.3
This command is no longer supported.
OBJECT-TYPE    
  INTEGER  

sBTAModulesNumberOfIntelligentModules 1.3.6.1.4.1.4779.1.3.4
The number of Intelligent Modules installed in the DS Unit.
OBJECT-TYPE    
  INTEGER  

sBTAModulesRPC 1.3.6.1.4.1.4779.1.3.5
OBJECT IDENTIFIER    

sBTAModulesSerial 1.3.6.1.4.1.4779.1.3.6
OBJECT IDENTIFIER    

sBTAModulesModem 1.3.6.1.4.1.4779.1.3.7
OBJECT IDENTIFIER    

sBTAModulesNumberOfRPCModules 1.3.6.1.4.1.4779.1.3.5.1
The number of DS30 Modules installed in the DS Unit.
OBJECT-TYPE    
  INTEGER  

sBTAModulesRPCTable 1.3.6.1.4.1.4779.1.3.5.2
Allows for control of individual outlets and individual RPC modules.
OBJECT-TYPE    
  SEQUENCE OF  
    SDSModulesRPCEntry

sBTAModulesRPCEntry 1.3.6.1.4.1.4779.1.3.5.2.1
The RPCs to control and get status on.
OBJECT-TYPE    
  SDSModulesRPCEntry  

sBTAModulesRPCIndex 1.3.6.1.4.1.4779.1.3.5.2.1.1
The index into the RPC table. Indexes for rpcs attached to ds74 modules are calculate with the following formula: ((module - 2) * 4) + port. For example module 3 port 1 = index 5.
OBJECT-TYPE    
  INTEGER  

sBTAModulesRPCName 1.3.6.1.4.1.4779.1.3.5.2.1.2
The name (unit id) of the rpc.
OBJECT-TYPE    
  DisplayString  

sBTAModulesRPCFirmwareVersion 1.3.6.1.4.1.4779.1.3.5.2.1.3
The firware version of the rpc.
OBJECT-TYPE    
  DisplayString  

sBTAModulesRPCCurrent 1.3.6.1.4.1.4779.1.3.5.2.1.4
The current reading for the power strip. If current measurement is not installed this value will always read 0.
OBJECT-TYPE    
  INTEGER  

sBTAModulesRPCMaxCurrent 1.3.6.1.4.1.4779.1.3.5.2.1.5
The maximum detected current reading for the power strip. If current measurement is not installed this value will always read 0. Setting this value to 0 will clear the maximum current detected.
OBJECT-TYPE    
  INTEGER  

sBTAModulesRPCVoltage 1.3.6.1.4.1.4779.1.3.5.2.1.6
The voltage reading for the power strip. If voltage measurement is not installed this value will always read 0.
OBJECT-TYPE    
  INTEGER  

sBTAModulesRPCPower 1.3.6.1.4.1.4779.1.3.5.2.1.7
The power reading for the power strip. If power measurement is not installed this value will always read 0.
OBJECT-TYPE    
  INTEGER  

sBTAModulesRPCTemperature 1.3.6.1.4.1.4779.1.3.5.2.1.8
The temperature reading for the power strip. Readings are in degrees C. If temperature measurement is not installed this value will always read 0.
OBJECT-TYPE    
  INTEGER  

sBTAModulesRPCRebootTimeout 1.3.6.1.4.1.4779.1.3.5.2.1.9
The length of off time for automatic reboot sequences. Currently a read-only value set to the fixed reboot timeout.
OBJECT-TYPE    
  INTEGER  

sBTAModulesRPCAllOutletsCmd 1.3.6.1.4.1.4779.1.3.5.2.1.10
Turns all outlets on, off or reboot. 0 = off 1 = on 2 = reboot A get will return unknown (6).
OBJECT-TYPE    
  INTEGER off(0), on(1), reboot(2), lockon(3), lockoff(4), unlock(5), unknown(6)  

sBTAModulesRPCAllOutletsStatus 1.3.6.1.4.1.4779.1.3.5.2.1.11
Reports status of outlets in a comma deliminated string. 0 = off 1 = on 2 = reboot 3 = locked on 4 = locked off
OBJECT-TYPE    
  DisplayString  

sBTAModulesRPCCurrentAlarmThreshold 1.3.6.1.4.1.4779.1.3.5.2.1.12
The current alarm threshold level *10. A value of 105 will set the level to 10.5.
OBJECT-TYPE    
  INTEGER  

sBTAModulesRPCOverVoltageThreshold 1.3.6.1.4.1.4779.1.3.5.2.1.13
The over voltage alarm threshold level *10. A value of 105 will set the level to 10.5.
OBJECT-TYPE    
  INTEGER  

sBTAModulesRPCUnderVoltageThreshold 1.3.6.1.4.1.4779.1.3.5.2.1.14
The under voltage alarm threshold level *10. A value of 105 will set the level to 10.5.
OBJECT-TYPE    
  INTEGER  

sBTAModulesRPCNumberOfOutlets 1.3.6.1.4.1.4779.1.3.5.2.1.15
Number of outlets for this RPC. This will be the size of outlet table for this RPC index.
OBJECT-TYPE    
  INTEGER  

sBTAModulesRPCCircuitBreaker 1.3.6.1.4.1.4779.1.3.5.2.1.16
Status of circuit breaker in power strip. 0=off 1=on.
OBJECT-TYPE    
  INTEGER off(0), on(1)  

sBTAModulesRPCOverTempThreshold 1.3.6.1.4.1.4779.1.3.5.2.1.17
The over temperature alarm threshold level *10. A value of 505 will set the level to 50.5.
OBJECT-TYPE    
  INTEGER  

sBTAModulesRPCUnitVA 1.3.6.1.4.1.4779.1.3.5.2.1.18
Total Volt-Amps for this RPC.
OBJECT-TYPE    
  INTEGER  

sBTAModulesRPCNumberOfBreakers 1.3.6.1.4.1.4779.1.3.5.2.1.19
Number of breakers for this RPC.
OBJECT-TYPE    
  INTEGER  

sBTAModulesRPCLowCurrentThreshold 1.3.6.1.4.1.4779.1.3.5.2.1.20
Low current threshold for this RPC.
OBJECT-TYPE    
  INTEGER  

sBTAModulesRPCVoltageSource 1.3.6.1.4.1.4779.1.3.5.2.1.21
Voltage source for this RPC.
OBJECT-TYPE    
  INTEGER  

sBTAModulesRPCSourceSwitchCount 1.3.6.1.4.1.4779.1.3.5.2.1.22
Count of Voltage Source Switches for this RPC.
OBJECT-TYPE    
  INTEGER  

sBTAModulesRPCNumberOfSensors 1.3.6.1.4.1.4779.1.3.5.2.1.23
Number of environmental sensors for this RPC.
OBJECT-TYPE    
  INTEGER  

sBTAModulesRPCType 1.3.6.1.4.1.4779.1.3.5.2.1.24
The type of RPC installed at the indexed location.
OBJECT-TYPE    
  DisplayString  

sBTAModulesRPCOutletTable 1.3.6.1.4.1.4779.1.3.5.3
Allows for control of individual outlets. The number of entries is contained in the sBTAModulesRPCOutletTableSize OID.
OBJECT-TYPE    
  SEQUENCE OF  
    SDSModulesRPCOutletEntry

sBTAModulesRPCOutletEntry 1.3.6.1.4.1.4779.1.3.5.3.1
The outlets to control and get status on.
OBJECT-TYPE    
  SDSModulesRPCOutletEntry  

sBTAModulesRPCOutletModuleIndex 1.3.6.1.4.1.4779.1.3.5.3.1.1
The index to the outlet entry.
OBJECT-TYPE    
  INTEGER  

sBTAModulesRPCOutletIndex 1.3.6.1.4.1.4779.1.3.5.3.1.2
The index to the outlet entry.
OBJECT-TYPE    
  INTEGER  

sBTAModulesRPCOutletState 1.3.6.1.4.1.4779.1.3.5.3.1.3
Getting this variable will return the state of the outlet. Valid return states are unknown, on, off, lockon, lockoff. 0 = off 1 = on 2 = reboot 3 = lockon (outlet is on and no changes are allowed) 4 = lockoff (outlet is off and no changes are allowed) 5 = unlock.
OBJECT-TYPE    
  INTEGER off(0), on(1), reboot(2), lockon(3), lockoff(4), unlock(5), unknown(6)  

sBTAModulesRPCOutletName 1.3.6.1.4.1.4779.1.3.5.3.1.4
The name of the outlet. Maximum size is 16 characters.
OBJECT-TYPE    
  DisplayString  

sBTAModulesRPCGroupCmd 1.3.6.1.4.1.4779.1.3.5.4
A character string listing the outlets that need to be controlled, turned off, or turn on as a group. Command is the first character followed by a space. Valid commads are 0=off,1=on, or 2=reboot. A list follows the command in the format module.outlet. For example 2 2.1,2.12,3.1 will reboot module 2 outlet 2&12 module 3 outlet 1.
OBJECT-TYPE    
  DisplayString  

sBTAModulesRPCCurrentGroupsCurrentTable 1.3.6.1.4.1.4779.1.3.5.8
A list of total current for RPCs in each current group
OBJECT-TYPE    
  SEQUENCE OF  
    SDSModulesRPCCurrentGroupsCurrentEntry

sBTAModulesRPCCurrentGroupsCurrentEntry 1.3.6.1.4.1.4779.1.3.5.8.1
Table of total current measurement by group
OBJECT-TYPE    
  SDSModulesRPCCurrentGroupsCurrentEntry  

groupCurrentIndex 1.3.6.1.4.1.4779.1.3.5.8.1.1
The index to a group total current.
OBJECT-TYPE    
  INTEGER  

groupCurrent 1.3.6.1.4.1.4779.1.3.5.8.1.2
Current total for all RPCs in group.
OBJECT-TYPE    
  INTEGER  

rpcGroup 1.3.6.1.4.1.4779.1.3.5.8.1.3
A character string listing the RPCs, by port index, that will be included in a measurement of total current. For each group, a sum will be periodically computed of currents of all listed RPCs, which will be compared to warning and emergency thresholds, generating appropriate traps as required by transit of a threshold. A maximum of 8 RPCs may be monitored within a group. The RPC must be connected and operating and the corresponding DS74 serial port must be configured for an RPC-SNMP device type to be allowed group membership.
OBJECT-TYPE    
  DisplayString  

warningThreshold 1.3.6.1.4.1.4779.1.3.5.8.1.4
The current level, in tenths of an amp, that will cause a Current Level Warning trap to be sent if the total current for the associated group if exceeded. Conversely, a Current Level Warning Clear trap will be sent whent the total group current falls below the threshold.
OBJECT-TYPE    
  INTEGER  

emergencyThreshold 1.3.6.1.4.1.4779.1.3.5.8.1.5
The current level, in tenths of an amp, that will cause a Current Level Emergency trap to be sent if the total current for the associated group if exceeded. Conversely, a Current Level Emergeny Clear trap will be sent whent the total group current falls below the threshold.
OBJECT-TYPE    
  INTEGER  

sBTAModulesRPCBreakersTable 1.3.6.1.4.1.4779.1.3.5.9
Allows monitoring of individual outlet strips on RPCs.
OBJECT-TYPE    
  SEQUENCE OF  
    SDSModulesRPCBreakersEntry

sBTAModulesRPCBreakersEntry 1.3.6.1.4.1.4779.1.3.5.9.1
Status organization by breaker.
OBJECT-TYPE    
  SDSModulesRPCBreakersEntry  

sBTAModulesRPCBreakersModulesIndex 1.3.6.1.4.1.4779.1.3.5.9.1.1
The index into the RPC table.
OBJECT-TYPE    
  INTEGER  

sBTAModulesRPCBreakersBreakersIndex 1.3.6.1.4.1.4779.1.3.5.9.1.2
The index into the RPC breaker table.
OBJECT-TYPE    
  INTEGER  

sBTAModulesRPCBreakersCircuitBreaker 1.3.6.1.4.1.4779.1.3.5.9.1.3
Status of circuit breaker in power strip. 0=off 1=on.
OBJECT-TYPE    
  INTEGER off(0), on(1)  

sBTAModulesRPCBreakersCurrent 1.3.6.1.4.1.4779.1.3.5.9.1.4
The detected current reading for the power strip. If current measurement is not installed this value will always read 0.
OBJECT-TYPE    
  INTEGER  

sBTAModulesRPCBreakersMaxCurrent 1.3.6.1.4.1.4779.1.3.5.9.1.5
The maximum detected current reading for the power strip. If current measurement is not installed this value will always read 0.
OBJECT-TYPE    
  INTEGER  

sBTAModulesRPCBreakersVoltage 1.3.6.1.4.1.4779.1.3.5.9.1.6
The voltage reading for the power strip. If voltage measurement is not installed this value will always read 0.
OBJECT-TYPE    
  INTEGER  

sBTAModulesRPCBreakersPower 1.3.6.1.4.1.4779.1.3.5.9.1.7
The power reading for the power strip. If voltage measurement is not installed this value will always read 0.
OBJECT-TYPE    
  INTEGER  

sBTAModulesRPCBreakersVA 1.3.6.1.4.1.4779.1.3.5.9.1.8
The volt-amps reading for the power strip. If voltage measurement is not installed this value will always read 0.
OBJECT-TYPE    
  INTEGER  

sBTAModulesRPCBreakersCurrentAlarmThreshold 1.3.6.1.4.1.4779.1.3.5.9.1.9
The current alarm threshold level *10. A value of 105 will set the level to 10.5.
OBJECT-TYPE    
  INTEGER  

sBTAControlResetUnit 1.3.6.1.4.1.4779.1.4.1
Setting this value to 1 will cause the unit to reset. A get of this OID will return 0.
OBJECT-TYPE    
  INTEGER noreset(0), reset(1)  

sBTAControlResetModules 1.3.6.1.4.1.4779.1.4.2
Setting this value to 1 will cause the unit to reset modules simular to the telnet RM command. A get of this OID will return 0.
OBJECT-TYPE    
  INTEGER noreset(0), reset(1)  

sBTAControlNumOfLoggedUsers 1.3.6.1.4.1.4779.1.4.3
Number of users logged in via telnet or SSH.
OBJECT-TYPE    
  INTEGER  

sBTAControlUserTable 1.3.6.1.4.1.4779.1.4.4
A list of users and user information. The number of entries is contained in the sBTAControlNumOfLoggedUsers OID.
OBJECT-TYPE    
  SEQUENCE OF  
    SDSControlUserEntry

sBTAControlUserEntry 1.3.6.1.4.1.4779.1.4.4.1
The users to get status on.
OBJECT-TYPE    
  SDSControlUserEntry  

sBTAControlUserIndex 1.3.6.1.4.1.4779.1.4.4.1.1
The index to the user entry.
OBJECT-TYPE    
  INTEGER  

sBTAControlUserName 1.3.6.1.4.1.4779.1.4.4.1.2
The username of the user.
OBJECT-TYPE    
  DisplayString  

sBTAControlUserAddress 1.3.6.1.4.1.4779.1.4.4.1.3
The IP address of the user.
OBJECT-TYPE    
  IpAddress  

sBTAControlUserConnection 1.3.6.1.4.1.4779.1.4.4.1.4
Type of connection. If unknown, user is logging out or the connection is invalid.
OBJECT-TYPE    
  INTEGER serialport(0), telnet(1), ssh(2), unknown(4)  

sBTAControlUserConnModule 1.3.6.1.4.1.4779.1.4.4.1.5
If the user is connected to a module, this value will report the module number connected to. If the value is 0 the user is not connected to a module.
OBJECT-TYPE    
  INTEGER  

sBTAControlUserConnPort 1.3.6.1.4.1.4779.1.4.4.1.6
The port number with in a module that the user is connected to. This usually only applies to connections to DS74 serial modules. Intelligent modules connections are always made on port 1. If value is 0 the user is not connected to a module.
OBJECT-TYPE    
  INTEGER  

sBTAControlUserTerminateUser 1.3.6.1.4.1.4779.1.4.4.1.7
Settings this OID to anything but 0 will terminate (log out) the user. A get of this OID will return 0.
OBJECT-TYPE    
  INTEGER terminate(1)  

sBTAFileTransferEnableUpgradeFTPFileTransfer 1.3.6.1.4.1.4779.1.5.1
Setting this OID to enableUpgradeFileTransferDownloadViaFTP (1) will start the FTP server and place the DS72 in upgrade mode. An FTP connection may then be established for the purpose of transmitting a firmware upgrade file.
OBJECT-TYPE    
  INTEGER enableUpgradeFileTransferDownloadViaFTP(1)  

mtrapargsInteger 1.3.6.1.4.1.4779.3.1
This OID allows baytech traps to be sent with an integer argument that may not be defined in the baytech MIB. A get of this OID will return 0.
OBJECT-TYPE    
  INTEGER  

mtrapargsIpAddress 1.3.6.1.4.1.4779.3.2
This OID allows bayteh traps to be sent with an IP address argument that may not be defined in the baytech MIB. A get of this OID will return 0.0.0.0.
OBJECT-TYPE    
  IpAddress  

mtrapargsString 1.3.6.1.4.1.4779.3.3
This OID allows baytech traps to be sent with an octet string argument that may not be defined in the baytech MIB. A get of this OID will return a NULL string.
OBJECT-TYPE    
  DisplayString  

mtrapargsGauge 1.3.6.1.4.1.4779.3.4
This OID allows baytech traps to be sent with a Gauge argument that may not be defined in the baytech MIB. A get of this OID will return 0.
OBJECT-TYPE    
  Gauge  

mtrapargsTimeTicks 1.3.6.1.4.1.4779.3.5
This OID allows baytech traps to be sent with a TimeTicks argument that may not be defined in the baytech MIB. A get of this OID will return 0.
OBJECT-TYPE    
  TimeTicks  

sBTAModuleIndex 1.3.6.1.4.1.4779.3.6
This OID allows baytech traps to be sent with an integer argument that may not be defined in the baytech MIB. This is an index to a specific DS module. Value will equal the slot of the module. A get of this OID will return 0.
OBJECT-TYPE    
  INTEGER  

sBTAOutletIndex 1.3.6.1.4.1.4779.3.7
This OID allows baytech traps to be sent with an integer argument that may not be defined in the baytech MIB. This is an index to a specific outlet in a DS module. Value is 1 to number of outlets controlled by the ds module. 0 represents all outlets. A get of this OID will return 0.
OBJECT-TYPE    
  INTEGER  

sBTAPortIndex 1.3.6.1.4.1.4779.3.8
This OID allows baytech traps to be sent with an integer argument that may not be defined in the baytech MIB. This is an index to a specific outlet in a DS module. Value is 1 to number of outlets controlled by the ds module. 0 represents all outlets. A get of this OID will return 0.
OBJECT-TYPE    
  INTEGER  

sBTAVoltageSource 1.3.6.1.4.1.4779.3.9
This OID allows baytech traps to be sent with an integer argument that may not be defined in the baytech MIB. This is the number associated with the voltage source in an RPC. Value is 1 or 2, depending on which voltage source is powering the RPC. A get of this OID will return 0.
OBJECT-TYPE    
  INTEGER  

sBTASourceSwitchCount 1.3.6.1.4.1.4779.3.10
This OID allows baytech traps to be sent with an integer argument that may not be defined in the baytech MIB. This is the number associated with the number of voltage source transitions in an RPC. Value is 0 to 255, an 8-bit w/rollover count of number of times voltage source has been switched from one source to another. A get of this OID will return 0.
OBJECT-TYPE    
  INTEGER  

sBTASensorIndex 1.3.6.1.4.1.4779.3.11
This OID allows baytech traps to be sent with an integer argument that may not be defined in the baytech MIB. This is an index to a specific sensor in a DS module. Value is 1 to number of sensors controlled by the ds module. A get of this OID will return 0.
OBJECT-TYPE    
  INTEGER  

sBTABreakerIndex 1.3.6.1.4.1.4779.3.12
This is an object which is sent along with a trap to designate a breaker number pertinent to a particular trap. This value will range from 1 to the total number of breakers inside the particular RPC. A get of this OID will return 0.
OBJECT-TYPE    
  INTEGER  

sBTAModulesRPCModPortTable 1.3.6.1.4.1.4779.1.3.5.5
Allows for control of individual outlets and individual RPC modules. The number of entries is contained in the sBTAModulesNumberOfRPCModules OID.
OBJECT-TYPE    
  SEQUENCE OF  
    SDSModulesRPCModPortEntry

sBTAModulesRPCModPortEntry 1.3.6.1.4.1.4779.1.3.5.5.1
The RPCs to control and get status on.
OBJECT-TYPE    
  SDSModulesRPCModPortEntry  

sRPCModuleIndex 1.3.6.1.4.1.4779.1.3.5.5.1.1
The module number index into the RPC table.
OBJECT-TYPE    
  INTEGER  

sRPCPortIndex 1.3.6.1.4.1.4779.1.3.5.5.1.2
The port number index into the RPC table. In the case of ds30 modules this number is always 1.
OBJECT-TYPE    
  INTEGER  

sRPCType 1.3.6.1.4.1.4779.1.3.5.5.1.3
Type of RPC at the module, port index.
OBJECT-TYPE    
  DisplayString  

sRPCName 1.3.6.1.4.1.4779.1.3.5.5.1.4
The name (unit id) of the rpc module.
OBJECT-TYPE    
  DisplayString  

sRPCFirmwareVersion 1.3.6.1.4.1.4779.1.3.5.5.1.5
The firware version of the rpc module.
OBJECT-TYPE    
  DisplayString  

sRPCCurrent 1.3.6.1.4.1.4779.1.3.5.5.1.6
The current reading for the power strip. If current measurement is not installed this value will always read 0.
OBJECT-TYPE    
  INTEGER  

sRPCMaxCurrent 1.3.6.1.4.1.4779.1.3.5.5.1.7
The maximum detected current reading for the power strip. If current measurement is not installed this value will always read 0. Setting this value to 0 will clear the maximum current detected.
OBJECT-TYPE    
  INTEGER  

sRPCVoltage 1.3.6.1.4.1.4779.1.3.5.5.1.8
The voltage reading for the power strip. If voltage measurement is not installed this value will always read 0.
OBJECT-TYPE    
  INTEGER  

sRPCPower 1.3.6.1.4.1.4779.1.3.5.5.1.9
The power reading for the power strip. If power measurement is not installed this value will always read 0.
OBJECT-TYPE    
  INTEGER  

sRPCTemperature 1.3.6.1.4.1.4779.1.3.5.5.1.10
The temperature reading for the power strip. Readings are in degrees C. If temperature measurement is not installed this value will always read 0.
OBJECT-TYPE    
  INTEGER  

sRPCRebootTimeout 1.3.6.1.4.1.4779.1.3.5.5.1.11
The length of off time for automatic reboot sequences. Currently a read-only value set to the fixed reboot timeout.
OBJECT-TYPE    
  INTEGER  

sRPCAllOutletsCmd 1.3.6.1.4.1.4779.1.3.5.5.1.12
Turns all outlets on, off or reboot. 0 = off 1 = on 2 = reboot 3 = lockon (will lock outlets to on state) 4 = lockoff (will lock outlets to off state) 5 = unlock (will unlock all outlets) A get will return unknown (6).
OBJECT-TYPE    
  INTEGER off(0), on(1), reboot(2), lockon(3), lockoff(4), unlock(5), unknown(6)  

sRPCAllOutletsStatus 1.3.6.1.4.1.4779.1.3.5.5.1.13
Reports status of outlets in a comma deliminated string. 0 = off 1 = on 2 = reboot 3 = locked on 4 = locked off
OBJECT-TYPE    
  DisplayString  

sRPCCurrentAlarmThreshold 1.3.6.1.4.1.4779.1.3.5.5.1.14
The current alarm threshold level *10. A value of 105 will set the level to 10.5.
OBJECT-TYPE    
  INTEGER  

sRPCOverVoltageThreshold 1.3.6.1.4.1.4779.1.3.5.5.1.15
The over voltage alarm threshold level *10. A value of 105 will set the level to 10.5.
OBJECT-TYPE    
  INTEGER  

sRPCUnderVoltageThreshold 1.3.6.1.4.1.4779.1.3.5.5.1.16
The under voltage alarm threshold level *10. A value of 105 will set the level to 10.5.
OBJECT-TYPE    
  INTEGER  

sRPCNumberOfOutlets 1.3.6.1.4.1.4779.1.3.5.5.1.17
Number of outlets for this RPC. This will be the size of outlet table for this RPC index.
OBJECT-TYPE    
  INTEGER  

sRPCCircuitBreaker 1.3.6.1.4.1.4779.1.3.5.5.1.18
Status of circuit breaker in power strip. 0=off 1=on.
OBJECT-TYPE    
  INTEGER off(0), on(1)  

sRPCOverTempThreshold 1.3.6.1.4.1.4779.1.3.5.5.1.19
The over temperature alarm threshold level *10. A value of 505 will set the level to 50.5.
OBJECT-TYPE    
  INTEGER  

sRPCUnitVA 1.3.6.1.4.1.4779.1.3.5.5.1.20
Number of outlets for this RPC. This will be the size of outlet table for this RPC index.
OBJECT-TYPE    
  INTEGER  

sRPCNumberOfBreakers 1.3.6.1.4.1.4779.1.3.5.5.1.21
Number of breakers for this RPC.
OBJECT-TYPE    
  INTEGER  

sRPCLowCurrentThreshold 1.3.6.1.4.1.4779.1.3.5.5.1.22
Low current threshold for this RPC.
OBJECT-TYPE    
  INTEGER  

sRPCVoltageSource 1.3.6.1.4.1.4779.1.3.5.5.1.23
Voltage source for this RPC.
OBJECT-TYPE    
  INTEGER  

sRPCSourceSwitchCount 1.3.6.1.4.1.4779.1.3.5.5.1.24
Voltage source switch count for this RPC.
OBJECT-TYPE    
  INTEGER  

sRPCNumberOfSensors 1.3.6.1.4.1.4779.1.3.5.5.1.25
Number of sensors for this RPC.
OBJECT-TYPE    
  INTEGER  

sBTAModulesRPCModPortOutletTable 1.3.6.1.4.1.4779.1.3.5.6
Allows for control of individual outlets. The number of entries is contained in the sBTAModulesRPCOutletTableSize OID.
OBJECT-TYPE    
  SEQUENCE OF  
    SDSModulesRPCModPortOutletEntry

sBTAModulesRPCModPortOutletEntry 1.3.6.1.4.1.4779.1.3.5.6.1
The outlets to control and get status on.
OBJECT-TYPE    
  SDSModulesRPCModPortOutletEntry  

sRPCOutletModuleIndex 1.3.6.1.4.1.4779.1.3.5.6.1.1
The module index to the outlet entry.
OBJECT-TYPE    
  INTEGER  

sRPCOutletPortIndex 1.3.6.1.4.1.4779.1.3.5.6.1.2
The port index to the outlet entry. In the case of ds30s this number is always 1.
OBJECT-TYPE    
  INTEGER  

sRPCOutletIndex 1.3.6.1.4.1.4779.1.3.5.6.1.3
The outlet index to the outlet entry.
OBJECT-TYPE    
  INTEGER  

sRPCOutletState 1.3.6.1.4.1.4779.1.3.5.6.1.4
Getting this variable will return the state of the outlet. Valid return states are unknown, on, off, lockon, lockoff. 0 = off 1 = on 2 = reboot 3 = lockon (outlet is on and no changes are allowed) 4 = lockoff (outlet is off and no changes are allowed) 5 = unlock.
OBJECT-TYPE    
  INTEGER off(0), on(1), reboot(2), lockon(3), lockoff(4), unlock(5), unknown(6)  

sRPCOutletName 1.3.6.1.4.1.4779.1.3.5.6.1.5
The name of the outlet. Maximum size is 16 characters.
OBJECT-TYPE    
  DisplayString  

sBTAModulesRPCModPortGroupCmd 1.3.6.1.4.1.4779.1.3.5.7
A character string listing the outlets that need to be rebooted, turned off, or turn on as a group. Command is the first character followed by a space. Valid commads are 0=off,1=on, or 2=reboot. A list follows the command in the format module.port.outlet. For example 2 2.1.1,2.1.12,3.4.1 will reboot module 2 port 1 outlet 2&12 module 3 port 4 outlet 1.
OBJECT-TYPE    
  DisplayString  

sRPCModPortBreakersTable 1.3.6.1.4.1.4779.1.3.5.10
Allows monitoring of individual outlet strips on RPCs.
OBJECT-TYPE    
  SEQUENCE OF  
    SRPCModPortBreakersEntry

sRPCModPortBreakersEntry 1.3.6.1.4.1.4779.1.3.5.10.1
Status organization by breaker.
OBJECT-TYPE    
  SRPCModPortBreakersEntry  

sRPCBreakersModIndex 1.3.6.1.4.1.4779.1.3.5.10.1.1
The module index into the RPC breaker table.
OBJECT-TYPE    
  INTEGER  

sRPCBreakersPortIndex 1.3.6.1.4.1.4779.1.3.5.10.1.2
The port index into the RPC breaker table.
OBJECT-TYPE    
  INTEGER  

sRPCBreakersBreakersIndex 1.3.6.1.4.1.4779.1.3.5.10.1.3
The breaker index into the RPC breaker table.
OBJECT-TYPE    
  INTEGER  

sRPCBreakersCircuitBreaker 1.3.6.1.4.1.4779.1.3.5.10.1.4
Status of circuit breaker in power strip. 0=off 1=on.
OBJECT-TYPE    
  INTEGER off(0), on(1)  

sRPCBreakersCurrent 1.3.6.1.4.1.4779.1.3.5.10.1.5
The detected current reading for the power strip. If current measurement is not installed this value will always read 0.
OBJECT-TYPE    
  INTEGER  

sRPCBreakersMaxCurrent 1.3.6.1.4.1.4779.1.3.5.10.1.6
The maximum detected current reading for the power strip. If current measurement is not installed this value will always read 0.
OBJECT-TYPE    
  INTEGER  

sRPCBreakersVoltage 1.3.6.1.4.1.4779.1.3.5.10.1.7
The voltage reading for the power strip. If voltage measurement is not installed this value will always read 0.
OBJECT-TYPE    
  INTEGER  

sRPCBreakersPower 1.3.6.1.4.1.4779.1.3.5.10.1.8
The power reading for the power strip. If voltage measurement is not installed this value will always read 0.
OBJECT-TYPE    
  INTEGER  

sRPCBreakersVA 1.3.6.1.4.1.4779.1.3.5.10.1.9
The volt-amps reading for the power strip. If voltage measurement is not installed this value will always read 0.
OBJECT-TYPE    
  INTEGER  

sRPCBreakersCurrentAlarmThreshold 1.3.6.1.4.1.4779.1.3.5.10.1.10
The current alarm threshold level x10. A value of 105 will set the level to 10.5.
OBJECT-TYPE    
  INTEGER  

sBTAModulesEnvironmentalObjectsTable 1.3.6.1.4.1.4779.1.6.1
Allows monitoring of individual outlet strips on RPCs.
OBJECT-TYPE    
  SEQUENCE OF  
    SDSModulesEnvironmentalObjectsEntry

sBTAModulesEnvironmentalObjectsEntry 1.3.6.1.4.1.4779.1.6.1.1
Status organization by sensor.
OBJECT-TYPE    
  SDSModulesEnvironmentalObjectsEntry  

sBTAModulesEnvironmentalModulesIndex 1.3.6.1.4.1.4779.1.6.1.1.1
Module Index for Environemntal table
OBJECT-TYPE    
  INTEGER  

sBTAModulesEnvironmentalSensorsIndex 1.3.6.1.4.1.4779.1.6.1.1.2
Sensor Index for Environemntal table
OBJECT-TYPE    
  INTEGER  

sBTAModulesEnvironmentalType 1.3.6.1.4.1.4779.1.6.1.1.3
Environmental Object Type.
OBJECT-TYPE    
  INTEGER  

sBTAModulesEnvironmentalName 1.3.6.1.4.1.4779.1.6.1.1.4
The name for the environmental object.
OBJECT-TYPE    
  DisplayString  

sBTAModulesEnvironmentalMeasurement 1.3.6.1.4.1.4779.1.6.1.1.5
The measurement or state for the object.
OBJECT-TYPE    
  INTEGER  

sBTAModulesEnvironmentalHiThreshold 1.3.6.1.4.1.4779.1.6.1.1.6
Hi threshold for object.
OBJECT-TYPE    
  INTEGER  

sBTAModulesEnvironmentalLoThreshold 1.3.6.1.4.1.4779.1.6.1.1.7
Lo threshold for object.
OBJECT-TYPE    
  INTEGER  

sBTAModulesEnvironmentalMax 1.3.6.1.4.1.4779.1.6.1.1.8
Max value recorded for object since last reset.
OBJECT-TYPE    
  INTEGER  

sBTAModulesEnvironmentalMin 1.3.6.1.4.1.4779.1.6.1.1.9
Min value recorded for object since last reset.
OBJECT-TYPE    
  INTEGER  

sBTAModulesEnvironmentalHiThresholdEn 1.3.6.1.4.1.4779.1.6.1.1.10
Hi threshold enable for object.
OBJECT-TYPE    
  INTEGER  

sBTAModulesEnvironmentalLoThresholdEn 1.3.6.1.4.1.4779.1.6.1.1.11
Lo threshold enable for object.
OBJECT-TYPE    
  INTEGER  

sBTAModulesEnvironmentalStateTrapEn 1.3.6.1.4.1.4779.1.6.1.1.12
Trap enable for environmental sensors with contacts.
OBJECT-TYPE    
  INTEGER  

sRPCEnvironmentalObjectsTable 1.3.6.1.4.1.4779.1.6.2
Allows monitoring of individual outlet strips on RPCs.
OBJECT-TYPE    
  SEQUENCE OF  
    SRPCEnvironmentalObjectsEntry

sRPCEnvironmentalObjectsEntry 1.3.6.1.4.1.4779.1.6.2.1
Status organization by sensor.
OBJECT-TYPE    
  SRPCEnvironmentalObjectsEntry  

sRPCEnvironmentalModuleIndex 1.3.6.1.4.1.4779.1.6.2.1.1
Module Index for Environemntal table
OBJECT-TYPE    
  INTEGER  

sRPCEnvironmentalPortIndex 1.3.6.1.4.1.4779.1.6.2.1.2
Port Index for Environemntal table
OBJECT-TYPE    
  INTEGER  

sRPCEnvironmentalSensorsIndex 1.3.6.1.4.1.4779.1.6.2.1.3
Sensor Index for Environemntal table
OBJECT-TYPE    
  INTEGER  

sRPCEnvironmentalType 1.3.6.1.4.1.4779.1.6.2.1.4
Environmental Object Type.
OBJECT-TYPE    
  INTEGER  

sRPCEnvironmentalName 1.3.6.1.4.1.4779.1.6.2.1.5
The name for the environmental object.
OBJECT-TYPE    
  DisplayString  

sRPCEnvironmentalMeasurement 1.3.6.1.4.1.4779.1.6.2.1.6
The measurement or state for the object.
OBJECT-TYPE    
  INTEGER  

sRPCEnvironmentalHiThreshold 1.3.6.1.4.1.4779.1.6.2.1.7
Hi threshold for object.
OBJECT-TYPE    
  INTEGER  

sRPCEnvironmentalLoThreshold 1.3.6.1.4.1.4779.1.6.2.1.8
Lo threshold for object.
OBJECT-TYPE    
  INTEGER  

sRPCEnvironmentalMax 1.3.6.1.4.1.4779.1.6.2.1.9
Max value recorded for object since last reset.
OBJECT-TYPE    
  INTEGER  

sRPCEnvironmentalMin 1.3.6.1.4.1.4779.1.6.2.1.10
Min value recorded for object since last reset.
OBJECT-TYPE    
  INTEGER  

sRPCEnvironmentalHiThresholdEn 1.3.6.1.4.1.4779.1.6.2.1.11
Hi threshold enable for object.
OBJECT-TYPE    
  INTEGER  

sRPCEnvironmentalLoThresholdEn 1.3.6.1.4.1.4779.1.6.2.1.12
Lo threshold enable for object.
OBJECT-TYPE    
  INTEGER  

sRPCEnvironmentalStateTrapEn 1.3.6.1.4.1.4779.1.6.2.1.13
Trap enable for environmental sensors with contacts.
OBJECT-TYPE    
  INTEGER  

sBTAEnvironmentalAllTemperatureSensorsHiThreshold 1.3.6.1.4.1.4779.1.6.3
Hi Threshold for all temperature sensors.
OBJECT-TYPE    
  INTEGER  

sBTAEnvironmentalAllTemperatureSensorsLoThreshold 1.3.6.1.4.1.4779.1.6.4
Lo Threshold for all temperature sensors.
OBJECT-TYPE    
  INTEGER  

sBTAEnvironmentalAllTemperatureSensorsHiThresholdTrapEnable 1.3.6.1.4.1.4779.1.6.5
Hi Threshold trap enable for all temperature sensors.
OBJECT-TYPE    
  INTEGER  

sBTAEnvironmentalAllTemperatureSensorsLoThresholdTrapEnable 1.3.6.1.4.1.4779.1.6.6
Lo Threshold trap enable for all temperature sensors.
OBJECT-TYPE    
  INTEGER  

sBTAEnvironmentalAllSensorsStateTrapEnable 1.3.6.1.4.1.4779.1.6.7
State change environmental sensor (ex: contact) trap enable.
OBJECT-TYPE    
  INTEGER