Cdx6500Bsc2780PortConfigEntry |
|
SEQUENCE |
|
|
|
|
cdx6500bsc2780PortNumber |
INTEGER |
|
|
cdx6500bsc2780ClockSource |
INTEGER |
|
|
cdx6500bsc2780ClockSpeed |
INTEGER |
|
|
cdx6500bsc2780Contention |
INTEGER |
|
|
cdx6500bsc2780ErrThreshCount |
INTEGER |
|
|
cdx6500bsc2780DisConnOnError |
INTEGER |
|
|
cdx6500bsc2780ConnType |
INTEGER |
|
|
cdx6500bsc2780InterBuffTimeout |
INTEGER |
|
|
cdx6500bsc2780PortSubAddr |
DisplayString |
|
|
cdx6500bsc2780ReConnRetry |
INTEGER |
|
|
cdx6500bsc2780AutocallMnemonic |
DisplayString |
|
|
cdx6500bsc2780RestrictConnDest |
DisplayString |
|
|
cdx6500bsc2780BillRec |
INTEGER |
|
|
cdx6500bsc2780DSRfollowSVC |
INTEGER |
|
|
cdx6500bsc2780DSRholdTime |
INTEGER |
|
|
cdx6500bsc2780PortOption |
INTEGER |
|
|
cdx6500bsc2780TrafficPriority |
INTEGER |
|
|
cdx6500bsc2780PortOptString |
DisplayString |
|
|
cdx6500bsc2780IdleDiscTimer |
INTEGER |
|
|
cdx6500bsc2780ElectricalInterfaceType |
INTEGER |
|
|
cdx6500bsc2780V24ElectricalInterfaceOption |
INTEGER |
|
|
cdx6500bsc2780HighSpeedElectricalInterfaceOption |
INTEGER |
|
|
cdx6500bsc2780RemoteType |
INTEGER |
|
Cdx6500Bsc2780PortStatEntry |
|
SEQUENCE |
|
|
|
|
cdx6500bsc2780StatPortNumber |
INTEGER |
|
|
cdx6500bsc2780PortStatus |
INTEGER |
|
|
cdx6500bsc2780PortState |
DisplayString |
|
|
cdx6500bsc2780PortSpeed |
INTEGER |
|
|
cdx6500bsc2780PortUtilIn |
INTEGER |
|
|
cdx6500bsc2780PortUtilOut |
INTEGER |
|
|
cdx6500bsc2780InMsgs |
Counter |
|
|
cdx6500bsc2780OutMsgs |
Counter |
|
|
cdx6500bsc2780InChars |
Counter |
|
|
cdx6500bsc2780OutChars |
Counter |
|
|
cdx6500bsc2780CharRateIn |
INTEGER |
|
|
cdx6500bsc2780CharRateOut |
INTEGER |
|
|
cdx6500bsc2780CrcBccErrs |
Counter |
|
cdx6500bsc2780PortConfigEntry |
1.3.6.1.4.1.449.2.1.2.1.1.11.1 |
A BSC2780 Configuration Table entry. Each entry
contains the configuration parameters for a single
BSC2780 port. |
Status: mandatory |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
Cdx6500Bsc2780PortConfigEntry |
|
|
cdx6500bsc2780Contention |
1.3.6.1.4.1.449.2.1.2.1.1.11.1.4 |
Indicates whether Half Duplex (hdx) or
Full Duplex (fdx) modem signals are being generated.
Full Duplex indicates communication is occuring
in both directions simultaneously between devices.
Half Duplex indicates transmission is occuring
in both directions, but only in one direction
at a time.
newvalHdx : same functionality as 'hdx', new enumeration
introduced for RFC1155 compatibility. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
hdx(0), fdx(1), newvalHdx(50) |
|
cdx6500bsc2780PortStatEntry |
1.3.6.1.4.1.449.2.1.3.1.1.11.1 |
A BSC2780 Port Statistic Table entry. Each entry
contains the statistics for a single BSC2780 port. |
Status: mandatory |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
Cdx6500Bsc2780PortStatEntry |
|
|