Amperion-MIB

File: Amperion-MIB.mib (78082 bytes)

Imported modules

SNMPv2-SMI SNMPv2-CONF SNMPv2-TC
RFC1213-MIB

Imported symbols

MODULE-IDENTITY OBJECT-TYPE NOTIFICATION-TYPE
enterprises Integer32 Unsigned32
Counter32 Counter64 Gauge32
IpAddress TimeTicks Opaque
OBJECT-GROUP DisplayString RowStatus
TruthValue ifIndex

Defined Types

PlCdEntry  
SEQUENCE    
  plCdIndex Integer32
  plCdType INTEGER
  plCdLink INTEGER
  plCdShortMacAddress Integer32
  plCdLongMacAddress DisplayString
  plCdHardwareVersion DisplayString
  plCdFirmwareVersion DisplayString
  plCdDriverVersion DisplayString
  plCdReset Integer32
  plCdFactoryReset Integer32
  plCdSaveAsPermanent Integer32
  plCdStatus Integer32
  plCdRemoteList DisplayString
  plCdNumRemoteList Integer32

PlNetEntry  
SEQUENCE    
  plNetShortMacAddress Integer32
  plNetLongMacAddress DisplayString
  plNetRowStatus RowStatus

PlInpEntry  
SEQUENCE    
  plInpTotalOctets Integer32
  plInpGain Integer32
  plInpAGC INTEGER
  plInpMaxGain Integer32
  plInpThresholds DisplayString
  plInpAttenuationGain Integer32
  plInpSamsDecode Integer32
  plInpSamsGood Integer32
  plInpSamsBad Integer32

PlInpNodeEntry  
SEQUENCE    
  plInpNodeReceivedPkts Integer32
  plInpNodeReceivedUnrecPkts Integer32
  plInpNodeReceivedCorrectedPkts Integer32
  plInpNodeReceivedOctets Integer32
  plInpNodeReceivedCorrectedOctets Integer32
  plInpNodeReceivedPower Integer32
  plInpNodePLR Integer32
  plInpNodeMeanBPC Integer32
  plInpNodeSNRChanges Integer32
  plInpNodeSNR DisplayString
  plInpNodeBPC DisplayString
  plInpNodeCFR DisplayString
  plInpNodeEnableCarriers DisplayString
  plInpNodeProtocolEnableCarriers DisplayString
  plInpNodeEnableProtocolEnableCarriers Integer32

AlarmsEntry  
SEQUENCE    
  alarmIndex Integer32
  description DisplayString

AmperionifEntry  
SEQUENCE    
  amperionifDescr DisplayString
  amperionifType INTEGER
  amperionifMtu Integer32
  amperionifSpeed Gauge32
  amperionifPhysAddress DisplayString
  amperionifAdminStatus INTEGER
  amperionifOperStatus INTEGER
  amperionifLastChange TimeTicks
  amperionifInOctets Counter32
  amperionifInUcastPkts Counter32
  amperionifInNUcastPkts Counter32
  amperionifInDiscards Counter32
  amperionifInErrors Counter32
  amperionifInUnknownProtos Counter32
  amperionifOutOctets Counter32
  amperionifOutUcastPkts Counter32
  amperionifOutNUcastPkts Counter32
  amperionifOutDiscards Counter32
  amperionifOutErrors Counter32
  amperionifOutQLen Gauge32
  amperionifSpecific OBJECT IDENTIFIER
  amperionWirelessConfigEssid DisplayString
  amperionWirelessConfigMode INTEGER
  amperionWirelessConfigChanFreq Unsigned32
  amperionWirelessConfigKey DisplayString
  amperionWirelessConfigWifType INTEGER
  amperionWirelessLinkQuality Unsigned32
  amperionWirelessSignalLevel Unsigned32
  amperionWirelessNoiseLevel Unsigned32
  amperionWirelessActivate TruthValue
  amperionWirelessConfigBitRate Integer32
  amperionWirelessConfigWDSPeer DisplayString

AmpMacAcceptEntry  
SEQUENCE    
  macAcceptTableIndex Unsigned32
  macAcceptTableRowStatus RowStatus
  macAcceptTableMacAddress DisplayString
  macAcceptTableWirelessIf Unsigned32

AmperionipAddrEntry  
SEQUENCE    
  amperionipAdEntAddr IpAddress
  amperionipAdEntIfName DisplayString
  amperionipAdEntNetMask IpAddress
  amperionipAdEntBcastAddr Integer32
  amperionipAdEntReasmMaxSize Integer32
  amperionipAdEntActivate TruthValue
  amperionipAdRowStatus RowStatus

SubscriberEntry  
SEQUENCE    
  index Unsigned32
  name DisplayString
  ipAddress IpAddress
  macAddress DisplayString
  serviceClass INTEGER
  rowStatus RowStatus

AmperionRouteEntry  
SEQUENCE    
  ipRouteDest IpAddress
  ipRouteIfIndex Integer32
  ipRouteMetric1 Integer32
  ipRouteMetric2 Integer32
  ipRouteMetric3 Integer32
  ipRouteMetric4 Integer32
  ipRouteNextHop IpAddress
  ipRouteType INTEGER
  ipRouteProto INTEGER
  ipRouteAge Integer32
  ipRouteMask IpAddress
  ipRouteMetric5 Integer32
  ipRouteInfo OBJECT IDENTIFIER
  ipDefRouteActivate TruthValue

OptimizationEntry  
SEQUENCE    
  extrIpaddress IpAddress
  extrChannelNumber Integer32
  upstreamFreq DisplayString
  downstreamFreq DisplayString
  rxGain DisplayString
  txGain DisplayString
  plcThroughput DisplayString
  upStreamDownStream INTEGER
  gpsInfo DisplayString

Defined Values

amperion 1.3.6.1.4.1.13995
Amperion Inc. private MIB
MODULE-IDENTITY    

ds2 1.3.6.1.4.1.13995.1
OBJECT IDENTIFIER    

powerline 1.3.6.1.4.1.13995.1.1
OBJECT IDENTIFIER    

plMibIIExtension 1.3.6.1.4.1.13995.1.1.1
OBJECT IDENTIFIER    

plCards 1.3.6.1.4.1.13995.1.1.1.2
OBJECT IDENTIFIER    

plCdNumber 1.3.6.1.4.1.13995.1.1.1.2.1
Number of Cards available. Maximum index of plCdTable
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

plCdTable 1.3.6.1.4.1.13995.1.1.1.2.2
Powerline Cards Table. List of attributes of each Card available in the System. Indexed by the number of the Card (from 1 to plCdNumber).
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PlCdEntry

plCdEntry 1.3.6.1.4.1.13995.1.1.1.2.2.1
Row of table plCdTable
Status: current Access: not-accessible
OBJECT-TYPE    
  PlCdEntry  

plCdIndex 1.3.6.1.4.1.13995.1.1.1.2.2.1.1
Number of powerline card. Maximum: plCdNumber
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32  

plCdType 1.3.6.1.4.1.13995.1.1.1.2.2.1.2
Type of card: 0 => HE 1 => CPE
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER he(0), cpe(1)  


plCdShortMacAddress 1.3.6.1.4.1.13995.1.1.1.2.2.1.4
Short MAC Address of the Card
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

plCdLongMacAddress 1.3.6.1.4.1.13995.1.1.1.2.2.1.5
Long MAC Address of the Card
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

plCdHardwareVersion 1.3.6.1.4.1.13995.1.1.1.2.2.1.6
Hardware Version
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

plCdFirmwareVersion 1.3.6.1.4.1.13995.1.1.1.2.2.1.7
Firmware Version
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

plCdDriverVersion 1.3.6.1.4.1.13995.1.1.1.2.2.1.8
Driver Version
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

plCdReset 1.3.6.1.4.1.13995.1.1.1.2.2.1.9
Reset to Saved Values. Soft Reset.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

plCdFactoryReset 1.3.6.1.4.1.13995.1.1.1.2.2.1.10
Reset to factory values. Hard Reset.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

plCdSaveAsPermanent 1.3.6.1.4.1.13995.1.1.1.2.2.1.11
Save MIB values as default values: the information of the Remote List (long MAC address and short MAC address of each user) is saved and will be restored after a reboot or a poweroff.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

plCdStatus 1.3.6.1.4.1.13995.1.1.1.2.2.1.12
Status related to the interface: 0 => OK.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

plCdRemoteList 1.3.6.1.4.1.13995.1.1.1.2.2.1.13
List of Long MAC Address that can be connected with HE (only HE). Returns a string with the list of long MAC address (not separated by spaces)
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

plCdNumRemoteList 1.3.6.1.4.1.13995.1.1.1.2.2.1.14
Number of CPE in remote list (only HE). This is the maximum value for cpeId in Network table.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

plNetwork 1.3.6.1.4.1.13995.1.1.2
OBJECT IDENTIFIER    

plNetTable 1.3.6.1.4.1.13995.1.1.2.1
Network Topology. Indexed by number of card and number of remote user (.plCdIndex.cpeId). Maximum values for indexes: plCdNumber and plCdNumRemoteList. Only available in HE.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PlNetEntry

plNetEntry 1.3.6.1.4.1.13995.1.1.2.1.1
Row of table plNetTable
Status: current Access: not-accessible
OBJECT-TYPE    
  PlNetEntry  

plNetShortMacAddress 1.3.6.1.4.1.13995.1.1.2.1.1.1
SMAC of remote CPE.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 1..9  

plNetLongMacAddress 1.3.6.1.4.1.13995.1.1.2.1.1.3
Long Mac Address of Remote Node.
Status: current Access: read-create
OBJECT-TYPE    
  DisplayString Size(0..14)  

plNetRowStatus 1.3.6.1.4.1.13995.1.1.2.1.1.8
Row Status
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

plTransmission 1.3.6.1.4.1.13995.1.1.3
OBJECT IDENTIFIER    

plInpTable 1.3.6.1.4.1.13995.1.1.3.2
Input Channel Table. Common input characteristics. Indexed by number of card. Maximum value of index: plCdNumber
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PlInpEntry

plInpEntry 1.3.6.1.4.1.13995.1.1.3.2.1
Row of table plInpTable
Status: current Access: not-accessible
OBJECT-TYPE    
  PlInpEntry  

plInpTotalOctets 1.3.6.1.4.1.13995.1.1.3.2.1.1
Total number of rx octets (including FEC overhead)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

plInpGain 1.3.6.1.4.1.13995.1.1.3.2.1.2
Reception gain
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

plInpAGC 1.3.6.1.4.1.13995.1.1.3.2.1.3
To enable or disable Adaptive Rx Gain Control. 0 => AGC disabled 1 => AGC enabled.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER agcdisabled(0), agcenabled(1)  

plInpMaxGain 1.3.6.1.4.1.13995.1.1.3.2.1.4
Maximum reception gain
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

plInpThresholds 1.3.6.1.4.1.13995.1.1.3.2.1.5
SNR Thresholds in dB. Returns a string containing 4 integers.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..255)  

plInpAttenuationGain 1.3.6.1.4.1.13995.1.1.3.2.1.6
Attenuation Gain (only HE)
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

plInpSamsDecode 1.3.6.1.4.1.13995.1.1.3.2.1.7
Number of decoded SAMS (only CPE)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

plInpSamsGood 1.3.6.1.4.1.13995.1.1.3.2.1.8
Number of used SAMS (only CPE)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

plInpSamsBad 1.3.6.1.4.1.13995.1.1.3.2.1.9
Number of discarded SAMS (only CPE)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

plInpNodeTable 1.3.6.1.4.1.13995.1.1.3.4
Input Characteristics Remote equipments connected
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PlInpNodeEntry

plInpNodeEntry 1.3.6.1.4.1.13995.1.1.3.4.1
Row of table plInpNodeTable
Status: current Access: not-accessible
OBJECT-TYPE    
  PlInpNodeEntry  

plInpNodeReceivedPkts 1.3.6.1.4.1.13995.1.1.3.4.1.1
Number of Packets received from cpeId user
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

plInpNodeReceivedUnrecPkts 1.3.6.1.4.1.13995.1.1.3.4.1.2
Number of Unrecoverable received packets
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

plInpNodeReceivedCorrectedPkts 1.3.6.1.4.1.13995.1.1.3.4.1.3
Number of Corrected (by FEC) received packets
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

plInpNodeReceivedOctets 1.3.6.1.4.1.13995.1.1.3.4.1.4
Number of Received bytes
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

plInpNodeReceivedCorrectedOctets 1.3.6.1.4.1.13995.1.1.3.4.1.5
Number of Corrected (by FEC) received bytes
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

plInpNodeReceivedPower 1.3.6.1.4.1.13995.1.1.3.4.1.6
Total received power
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

plInpNodePLR 1.3.6.1.4.1.13995.1.1.3.4.1.7
Packet Loss Rate
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

plInpNodeMeanBPC 1.3.6.1.4.1.13995.1.1.3.4.1.8
Mean BPC: sum of current bits configuration
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

plInpNodeSNRChanges 1.3.6.1.4.1.13995.1.1.3.4.1.9
Changes of SNR
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

plInpNodeSNR 1.3.6.1.4.1.13995.1.1.3.4.1.10
String with SNR per carrier: contains 512 bytes if it is a HE or 768 if it is a CPE.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

plInpNodeBPC 1.3.6.1.4.1.13995.1.1.3.4.1.11
String with BPC per carrier configuration: contains 256 bytes if it is a HE or 384 if it is a CPE.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

plInpNodeCFR 1.3.6.1.4.1.13995.1.1.3.4.1.12
String with CFR per carrier: contains 512 bytes if it is a HE or 768 if it is a CPE.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

plInpNodeEnableCarriers 1.3.6.1.4.1.13995.1.1.3.4.1.13
String with enabled (1) and disabled (0) carriers: contains 256 bytes if it is a HE or 384 if it is a CPE.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..255)  

plInpNodeProtocolEnableCarriers 1.3.6.1.4.1.13995.1.1.3.4.1.14
String with enabled (1) and disabled (0) carriers: contains 256 bytes if it is a HE or 384 if it is a CPE.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

plInpNodeEnableProtocolEnableCarriers 1.3.6.1.4.1.13995.1.1.3.4.1.15
Enable protocol (1) and disable protocol (0).
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

plTraps 1.3.6.1.4.1.13995.1.1.4
OBJECT IDENTIFIER    

plRemoteCPE 1.3.6.1.4.1.13995.1.1.5
OBJECT IDENTIFIER    

internal 1.3.6.1.4.1.13995.1.2
OBJECT IDENTIFIER    

amperionSystem 1.3.6.1.4.1.13995.2
OBJECT IDENTIFIER    

serialNumber 1.3.6.1.4.1.13995.2.1
The serial number of the board, which is unique per part number
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..32)  

partNumber 1.3.6.1.4.1.13995.2.2
The part number of the board, which identifies the board type
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..32)  

rombootVersion 1.3.6.1.4.1.13995.2.3
The string that identifies the Romboot software
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

alarms 1.3.6.1.4.1.13995.2.4
Dynamic alarm table - shows all the outstanding alarms on the system
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AlarmsEntry

alarmsEntry 1.3.6.1.4.1.13995.2.4.1
Row of table alarms
Status: current Access: not-accessible
OBJECT-TYPE    
  AlarmsEntry  

alarmIndex 1.3.6.1.4.1.13995.2.4.1.1
The alarmIndex uniquely identifies alarms on the system
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32  

description 1.3.6.1.4.1.13995.2.4.1.2
Textual description of the alarm
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

productType 1.3.6.1.4.1.13995.2.5
injector/extractor/repeator
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER unknown(0), ohInjector(1), ohExtractor(2), ohRepeater(3), ohRepeaterExt(4), ugInjector(5), ugExtractor(6), ugRepeater(7), ugRepeaterExt(8)  

linuxVersion 1.3.6.1.4.1.13995.2.8
The string that identifies the Linux kernel software
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

amperionSysDescr 1.3.6.1.4.1.13995.2.10
A textual description of the entity. This value should include the full name and version identification of the system's hardware type, software operating-system, and networking software. It is mandatory that this only contain printable ASCII characters.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

amperionSysObjectID 0.0.1.3.6.1.4.1.13995.2.11
The vendor's authoritative identification of the network management subsystem contained in the entity. This value is allocated within the SMI enterprises subtree (1.3.6.1.4.1) and provides an easy and unambiguous means for determining `what kind of box' is being managed. For example, if vendor `Flintstones, Inc.' was assigned the subtree 1.3.6.1.4.1.4242, it could assign the identifier 1.3.6.1.4.1.4242.1.1 to its `Fred Router'.
Status: current Access: read-only
OBJECT-TYPE    
  OBJECT IDENTIFIER  

amperionSysUpTime 1.3.6.1.4.1.13995.2.12
The time (in hundredths of a second) since the network management portion of the system was last re-initialized.
Status: current Access: read-only
OBJECT-TYPE    
  TimeTicks  

amperionSysContact 1.3.6.1.4.1.13995.2.13
The textual identification of the contact person for this managed node, together with information on how to contact this person.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..255)  

amperionSysName 1.3.6.1.4.1.13995.2.14
An administratively-assigned name for this managed node. By convention, this is the node's fully-qualified domain name.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..255)  

amperionSysLocation 1.3.6.1.4.1.13995.2.15
The physical location of this node (e.g., `telephone closet, 3rd floor').
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..255)  

amperionSysServices 1.3.6.1.4.1.13995.2.16
A value which indicates the set of services that this entity primarily offers. The value is a sum. This sum initially takes the value zero, Then, for each layer, L, in the range 1 through 7, that this node performs transactions for, 2 raised to (L - 1) is added to the sum. For example, a node which performs primarily routing functions would have a value of 4 (2^(3-1)). In contrast, a node which is a host offering application services would have a value of 72 (2^(4-1) + 2^(7-1)). Note that in the context of the Internet suite of protocols, values should be calculated accordingly: layer functionality 1 physical (e.g., repeaters) 2 datalink/subnetwork (e.g., bridges) 3 internet (e.g., IP gateways) 4 end-to-end (e.g., IP hosts) 7 applications (e.g., mail relays) For systems including OSI protocols, layers 5 and 6 may also be counted.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..127  

amperionTrapMgr1 1.3.6.1.4.1.13995.2.18
IP address of Manager receceiving traps
Status: current Access: read-write
OBJECT-TYPE    
  IpAddress  

amperionTrapMgr2 1.3.6.1.4.1.13995.2.19
IP address of Manager receceiving traps
Status: current Access: read-write
OBJECT-TYPE    
  IpAddress  

amperionTrapMgr3 1.3.6.1.4.1.13995.2.20
amperionTrapMgr3
Status: current Access: read-write
OBJECT-TYPE    
  IpAddress  

userGpsInfoString 1.3.6.1.4.1.13995.2.6
User defined string for the user to put the GPS info of this device
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(1..128)  

softwareUpgrade 1.3.6.1.4.1.13995.3
OBJECT IDENTIFIER    

serverAddress 1.3.6.1.4.1.13995.3.1
Name or IP Address of the primary file server from which to retrieve new software.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..80)  

currentState 1.3.6.1.4.1.13995.3.3
Current state of the software upgrade.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER idle(1), inProgress(2)  

bootPartition 1.3.6.1.4.1.13995.3.4
Image in this partition will be used when the system boots.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER primary(1), backup(2)  

upgradePartition 1.3.6.1.4.1.13995.3.5
Default partition to erase and load with a new image.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER primary(1), backup(2)  

currentPartition 1.3.6.1.4.1.13995.3.6
Partition from which currently running software was loaded.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER unknown(0), primary(1), backup(2)  

commandOptions 1.3.6.1.4.1.13995.3.7
Software upgrade options: Reserved for future use
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..80)  

primaryPartitionContents 1.3.6.1.4.1.13995.3.2
Description of image in primary partition.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

primaryCRC 1.3.6.1.4.1.13995.3.9
CRC status of image in primary partition.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER unknown(0), ok(1), failed(2)  

backupPartitionContents 1.3.6.1.4.1.13995.3.8
Description of image in backup partition.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

backupCRC 1.3.6.1.4.1.13995.3.10
CRC status of image in backup partition.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER unknown(0), ok(1), failed(2)  

lastStatus 1.3.6.1.4.1.13995.3.11
Status of current or last software upgrade performed (since last reboot).
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

filename 1.3.6.1.4.1.13995.3.12
Path to filename to retrieve for software upgrade
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..80)  

server1Address 1.3.6.1.4.1.13995.3.13
Name or IP Address of the alternate file server from which to retrieve new software.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..80)  

server2Address 1.3.6.1.4.1.13995.3.14
Name or IP Address of the second alternate file server from which to retrieve new software.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..80)  

upgradeSchedule 1.3.6.1.4.1.13995.3.15
Scheduled upgrade date and time in MMDDhhmm format.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..80)  

rebootSchedule 1.3.6.1.4.1.13995.3.16
Scheduled reboot date and time in MMDDhhmm format.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..80)  

login 1.3.6.1.4.1.13995.3.17
login to use for software upgrade file server access.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..80)  

password 1.3.6.1.4.1.13995.3.18
password to use for software upgrade file server access.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..80)  

swupgradeCompleted 1.3.6.1.4.1.13995.3.19
swupgradeCompleted
Status: current Access: read-write
NOTIFICATION-TYPE    

psGroup 1.3.6.1.4.1.13995.4
OBJECT IDENTIFIER    

psImageChecksumError 1.3.6.1.4.1.13995.4.14
The power supply is notifying the main digital board that its main image crc is incorrect. The main digital board needs to reprogram the new power supply image again, or revert back to an older good image
Status: current Access: read-write
NOTIFICATION-TYPE    

criticalBatteryShutdownWarning 1.3.6.1.4.1.13995.4.15
The power supply is warning the main digital board that we have lost AC Line voltage and the battery is running low. The system will be shutting down in seconds. Perform necessary backup.
Status: current Access: read-write
NOTIFICATION-TYPE    

p12vOutOfRange 1.3.6.1.4.1.13995.4.16
The power supply is warning the main digital board that the +12v regulator is out of range. If the condition is such that it is too high, the decision may be to shutdown the regulator to avoid destroying the hardware
Status: current Access: read-write
NOTIFICATION-TYPE    

m8point5vOutOfRange 1.3.6.1.4.1.13995.4.17
The power supply is warning the main digital board that the -8.5v regulator is out of range. Note that the -8.5v regulator is the same regulator as the +12v. If the condition is such that it is too high, the decision may be to shutdown the regulator to avoid destroying the hardware.
Status: current Access: read-write
NOTIFICATION-TYPE    

p5vOutOfRange 1.3.6.1.4.1.13995.4.18
The power supply is warning the main digital board that the +5v regulator is out of range. If the condition is such that it is too high, the decision may be to shutdown the regulator to avoid destroying the hardware.
Status: current Access: read-write
NOTIFICATION-TYPE    

p3point3vOutOfRange 1.3.6.1.4.1.13995.4.19
The power supply is warning the main digital board that the +3.3v regulator is out of range. If the condition is such that it is too high, the decision may be to shutdown the regulator to avoid destroying the hardware.
Status: current Access: read-write
NOTIFICATION-TYPE    

batteryVoltsOutOfRange 1.3.6.1.4.1.13995.4.20
The power supply is warning the main digital board that the battery voltage is out of range.
Status: current Access: read-write
NOTIFICATION-TYPE    

mcuTempOutOfRange 1.3.6.1.4.1.13995.4.21
The power supply is warning the main digital board that the microcontroller unit core temperature is out of range.
Status: current Access: read-write
NOTIFICATION-TYPE    

batteryTempOutOfRange 1.3.6.1.4.1.13995.4.22
The power supply is warning the main digital board that the battery temperature is out of range
Status: current Access: read-write
NOTIFICATION-TYPE    

psDetectedCommLapse 1.3.6.1.4.1.13995.4.23
Power Supply notifies main digital board that it did not communnicate to the power supply within the agreed upon periodic interval
Status: current Access: read-write
NOTIFICATION-TYPE    

criticalRequestAborted 1.3.6.1.4.1.13995.4.24
The power supply is notifying the main digital board that one of the critical requests was aborted due to not receiving it twice in a row.
Status: current Access: read-write
NOTIFICATION-TYPE    

powerSupplyInternalError 1.3.6.1.4.1.13995.4.25
Power Supply / netmgt (PS thread) detected an internal error condition
Status: current Access: read-write
NOTIFICATION-TYPE    

psBatteryNotConnected 1.3.6.1.4.1.13995.4.26
Power Supply Battery Not Connected. There is no battery backup for the system.
Status: current Access: read-write
NOTIFICATION-TYPE    

psAcOnOff 1.3.6.1.4.1.13995.4.27
Power Supply detected AC going ON / OFF
Status: current Access: read-write
NOTIFICATION-TYPE    

psHardwareError 1.3.6.1.4.1.13995.4.29
The power supply is notifying the main digital board that it incurred a hardware error
Status: current Access: read-write
NOTIFICATION-TYPE    

npuDetectedCommLapse 1.3.6.1.4.1.13995.4.34
Network processing unit could not communnicate to the power supply
Status: current Access: read-write
NOTIFICATION-TYPE    

acLineVoltage 1.3.6.1.4.1.13995.4.1
State of AC Line voltage (on/off)
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER off(0), on(1)  

plus12v 1.3.6.1.4.1.13995.4.2
Regulated 12 volt supply
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

minus8point5v 1.3.6.1.4.1.13995.4.3
Regulated -8.5 volt supply
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

plus5v 1.3.6.1.4.1.13995.4.4
Regulated +5 volt supply
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

plus3point3v 1.3.6.1.4.1.13995.4.5
Regulated +3.3 volt supply
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

batteryCaseTemp 1.3.6.1.4.1.13995.4.6
Battery Case Temperature
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

internalMcuTemp 1.3.6.1.4.1.13995.4.7
Internal Micro Controller Unit Temperature
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

batteryCurrent 1.3.6.1.4.1.13995.4.8
Battery Current
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

batteryVoltage 1.3.6.1.4.1.13995.4.9
Battery Voltage
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

mcuSoftwareVersion 1.3.6.1.4.1.13995.4.10
Micro Controller Unit Software Version
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..30)  

powerCycleNpu 1.3.6.1.4.1.13995.4.11
Power Cycle the Network Processor Unit
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER idle(0), commit(1)  

psMode 1.3.6.1.4.1.13995.4.12
Power Supply mode, normal mode is protocol; dump mode is a debug mode which displays debug prints from the MCU
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER protocol(0), dump(1)  

shutdownNpu 1.3.6.1.4.1.13995.4.13
Shut down 12v, -8.5v, 3.3v and 5v regulators driving the Network Processor Unit. This should only be used if one of the voltages is too high.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER idle(0), commit(1)  

psEt 1.3.6.1.4.1.13995.4.30
Power Supply elapsed time since powerup
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

npuEt 1.3.6.1.4.1.13995.4.31
Power Supply elapsed time since powerup
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

npuPuTimes 1.3.6.1.4.1.13995.4.32
Number of times the Network Processing Unit has been powered up.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

eventDescription 1.3.6.1.4.1.13995.4.33
Description of the Last Event - Used in sending traps
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

psHardwareVersion 1.3.6.1.4.1.13995.4.28
Hardware Version of the Power SUpply
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..30)  

amperionInterfaces 1.3.6.1.4.1.13995.5
OBJECT IDENTIFIER    

interfaceAdminDown 1.3.6.1.4.1.13995.5.3
Admin of Interface being set down
Status: current Access: read-only
NOTIFICATION-TYPE    

interfaceAdminUp 1.3.6.1.4.1.13995.5.4
Interface is being set up
Status: current Access: read-only
NOTIFICATION-TYPE    

amperionifNumber 1.3.6.1.4.1.13995.5.1
The number of network interfaces (regardless of their current state) present on this system.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

amperionifTable 1.3.6.1.4.1.13995.5.2
A list of interface entries. The number of entries is given by the value of ifNumber.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AmperionifEntry

amperionifEntry 1.3.6.1.4.1.13995.5.2.1
Row of table amperionifTable
Status: current Access: not-accessible
OBJECT-TYPE    
  AmperionifEntry  

amperionifDescr 1.3.6.1.4.1.13995.5.2.1.2
A textual string containing information about the interface. This string should include the name of the manufacturer, the product name and the version of the hardware interface.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

amperionifType 1.3.6.1.4.1.13995.5.2.1.3
The type of interface, distinguished according to the physical/link protocol(s) immediately `below' the network layer in the protocol stack.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER other(1), regular1822(2), hdh1822(3), ddnx25(4), rfc877x25(5), ethernetcsmacd(6), iso88023csmacd(7), iso88024tokenBus(8), iso88025tokenRing(9), iso88026man(10), starLan(11), proteon10Mbit(12), proteon80Mbit(13), hyperchannel(14), fddi(15), lapb(16), sdlc(17), ds1(18), e1(19), basicISDN(20), primaryISDN(21), propPointToPointSerial(22), ppp(23), softwareLoopback(24), eon(25), ethernet3Mbit(26), nsip(27), slip(28), ultra(29), ds3(30), sip(31), framerelay(32), ieee80211b(33), ieee80211a(34), ieee80211g(35)  

amperionifMtu 1.3.6.1.4.1.13995.5.2.1.4
The size of the largest datagram which can be sent/received on the interface, specified in octets. For interfaces that are used for transmitting network datagrams, this is the size of the largest network datagram that can be sent on the interface.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

amperionifSpeed 1.3.6.1.4.1.13995.5.2.1.5
An estimate of the interface's current bandwidth in bits per second. For interfaces which do not vary in bandwidth or for those where no accurate estimation can be made, this object should contain the nominal bandwidth.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

amperionifPhysAddress 1.3.6.1.4.1.13995.5.2.1.6
The interface's address at the protocol layer immediately `below' the network layer in the protocol stack. For interfaces which do not have such an address (e.g., a serial line), this object should contain an octet string of zero length.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

amperionifAdminStatus 1.3.6.1.4.1.13995.5.2.1.7
The desired state of the interface. The testing(3) state indicates that no operational packets can be passed.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER up(1), down(2), testing(3)  

amperionifOperStatus 1.3.6.1.4.1.13995.5.2.1.8
The current operational state of the interface. The testing(3) state indicates that no operational packets can be passed.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER up(1), down(2), testing(3)  

amperionifLastChange 1.3.6.1.4.1.13995.5.2.1.9
The value of sysUpTime at the time the interface entered its current operational state. If the current state was entered prior to the last re- initialization of the local network management subsystem, then this object contains a zero value.
Status: current Access: read-only
OBJECT-TYPE    
  TimeTicks  

amperionifInOctets 1.3.6.1.4.1.13995.5.2.1.10
The total number of octets received on the interface, including framing characters.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

amperionifInUcastPkts 1.3.6.1.4.1.13995.5.2.1.11
The number of subnetwork-unicast packets delivered to a higher-layer protocol.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

amperionifInNUcastPkts 1.3.6.1.4.1.13995.5.2.1.12
The number of non-unicast (i.e., subnetwork- broadcast or subnetwork-multicast) packets delivered to a higher-layer protocol.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

amperionifInDiscards 1.3.6.1.4.1.13995.5.2.1.13
The number of inbound packets which were chosen to be discarded even though no errors had been detected to prevent their being deliverable to a higher-layer protocol. One possible reason for discarding such a packet could be to free up buffer space.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

amperionifInErrors 1.3.6.1.4.1.13995.5.2.1.14
The number of inbound packets that contained errors preventing them from being deliverable to a higher-layer protocol.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

amperionifInUnknownProtos 1.3.6.1.4.1.13995.5.2.1.15
The number of packets received via the interface which were discarded because of an unknown or unsupported protocol.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

amperionifOutOctets 1.3.6.1.4.1.13995.5.2.1.16
The total number of octets transmitted out of the interface, including framing characters.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

amperionifOutUcastPkts 1.3.6.1.4.1.13995.5.2.1.17
The total number of packets that higher-level protocols requested be transmitted to a subnetwork-unicast address, including those that were discarded or not sent.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

amperionifOutNUcastPkts 1.3.6.1.4.1.13995.5.2.1.18
The total number of packets that higher-level protocols requested be transmitted to a non- unicast (i.e., a subnetwork-broadcast or subnetwork-multicast) address, including those that were discarded or not sent.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

amperionifOutDiscards 1.3.6.1.4.1.13995.5.2.1.19
The number of outbound packets which were chosen to be discarded even though no errors had been detected to prevent their being transmitted. One possible reason for discarding such a packet could be to free up buffer space.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

amperionifOutErrors 1.3.6.1.4.1.13995.5.2.1.20
The number of outbound packets that could not be transmitted because of errors.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

amperionifOutQLen 1.3.6.1.4.1.13995.5.2.1.21
The length of the output packet queue (in packets).
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

amperionifSpecific 1.3.6.1.4.1.13995.5.2.1.22
A reference to MIB definitions specific to the particular media being used to realize the interface. For example, if the interface is realized by an ethernet, then the value of this object refers to a document defining objects specific to ethernet. If this information is not present, its value should be set to the OBJECT IDENTIFIER { 0 0 }, which is a syntatically valid object identifier, and any conformant implementation of ASN.1 and BER must be able to generate and recognize this value.
Status: current Access: read-only
OBJECT-TYPE    
  OBJECT IDENTIFIER  

amperionWirelessConfigEssid 1.3.6.1.4.1.13995.5.2.1.23
802.11 network name
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..33)  

amperionWirelessConfigMode 1.3.6.1.4.1.13995.5.2.1.24
802.11 station operational mode
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER none(0), adhoc(1), managed(2), master(3), repeater(4)  

amperionWirelessConfigChanFreq 1.3.6.1.4.1.13995.5.2.1.25
802.11 Channel ID
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32  

amperionWirelessConfigKey 1.3.6.1.4.1.13995.5.2.1.26
802.11 encryption or scrambling keys and encryption mode.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..33)  

amperionWirelessConfigWifType 1.3.6.1.4.1.13995.5.2.1.30
802.11 protocol type.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER wtype11a(1), wtype11b(2), wtype11g(3)  

amperionWirelessLinkQuality 1.3.6.1.4.1.13995.5.2.1.27
A measure of how good the received signal is.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

amperionWirelessSignalLevel 1.3.6.1.4.1.13995.5.2.1.28
Received signal strength (how strong the received signal is).
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

amperionWirelessNoiseLevel 1.3.6.1.4.1.13995.5.2.1.29
Background noise level (when no packet is transmited).
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

amperionWirelessActivate 1.3.6.1.4.1.13995.5.2.1.1
Command to activate 802.11 parameters on demand.
Status: current Access: read-write
OBJECT-TYPE    
  TruthValue  

amperionWirelessConfigBitRate 1.3.6.1.4.1.13995.5.2.1.31
The bit transmission rate in Megabits per second. (0 = autonegotiated)
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

amperionWirelessConfigWDSPeer 1.3.6.1.4.1.13995.5.2.1.32
The MAC address of any WDS peer.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..80)  

amperionWireless 1.3.6.1.4.1.13995.6
OBJECT IDENTIFIER    

ampMacAcceptTable 1.3.6.1.4.1.13995.6.3
List of Mac address to be accepted
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AmpMacAcceptEntry

ampMacAcceptEntry 1.3.6.1.4.1.13995.6.3.1
Row of table ampMacAcceptTable
Status: current Access: not-accessible
OBJECT-TYPE    
  AmpMacAcceptEntry  

macAcceptTableIndex 1.3.6.1.4.1.13995.6.3.1.3
Unique index
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32 1..65536  

macAcceptTableRowStatus 1.3.6.1.4.1.13995.6.3.1.2
Row Status
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

macAcceptTableMacAddress 1.3.6.1.4.1.13995.6.3.1.1
Mac address to be accepted
Status: current Access: read-create
OBJECT-TYPE    
  DisplayString Size(0..17)  

macAcceptTableWirelessIf 1.3.6.1.4.1.13995.6.3.1.4
The wireless interface (e.g. wlan0) that ACL table is applied to.
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32  

accessControlStatus 1.3.6.1.4.1.13995.6.1
Status of the access control table
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

amperionipAddrTable 1.3.6.1.4.1.13995.7
The table of addressing information relevant to this entity's IP addresses.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AmperionipAddrEntry

amperionipAddrEntry 1.3.6.1.4.1.13995.7.1
Row of table amperionipAddrTable
Status: current Access: not-accessible
OBJECT-TYPE    
  AmperionipAddrEntry  

amperionipAdEntAddr 1.3.6.1.4.1.13995.7.1.1
The IP address to which this entry's addressing information pertains.
Status: current Access: not-accessible
OBJECT-TYPE    
  IpAddress  

amperionipAdEntIfName 1.3.6.1.4.1.13995.7.1.2
The name which uniquely identifies the interface to which this entry is applicable.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(1..80)  

amperionipAdEntNetMask 1.3.6.1.4.1.13995.7.1.3
The subnet mask associated with the IP address of this entry. The value of the mask is an IP address with all the network bits set to 1 and all the hosts bits set to 0.
Status: current Access: read-only
OBJECT-TYPE    
  IpAddress  

amperionipAdEntBcastAddr 1.3.6.1.4.1.13995.7.1.4
The value of the least-significant bit in the IP broadcast address used for sending datagrams on the (logical) interface associated with the IP address of this entry. For example, when the Internet standard all-ones broadcast address is used, the value will be 1. This value applies to both the subnet and network broadcasts addresses used by the entity on this (logical) interface.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

amperionipAdEntReasmMaxSize 1.3.6.1.4.1.13995.7.1.5
The size of the largest IP datagram which this entity can re-assemble from incoming IP fragmented datagrams received on this interface.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..65535  

amperionipAdEntActivate 1.3.6.1.4.1.13995.7.1.7
Command to activate the new IP address/netmask on demand.
Status: current Access: read-create
OBJECT-TYPE    
  TruthValue  

amperionipAdRowStatus 1.3.6.1.4.1.13995.7.1.6
Row status
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

qualityOfService 1.3.6.1.4.1.13995.8
OBJECT IDENTIFIER    

serviceClassA 1.3.6.1.4.1.13995.8.1
Service Class A (Bandwidth in Kbps)
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 64..65536  

serviceClassB 1.3.6.1.4.1.13995.8.2
Service Class B (Bandwidth in Kbps)
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 64..65536  

serviceClassC 1.3.6.1.4.1.13995.8.3
Service Class C (Bandwidth in Kbps)
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 64..65536  

serviceClassD 1.3.6.1.4.1.13995.8.4
Service Class D (Bandwidth in Kbps)
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 64..65536  

subscriberTable 1.3.6.1.4.1.13995.8.5
List of subscribers
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SubscriberEntry

subscriberEntry 1.3.6.1.4.1.13995.8.5.1
Row of table subscriberTable
Status: current Access: not-accessible
OBJECT-TYPE    
  SubscriberEntry  

index 1.3.6.1.4.1.13995.8.5.1.1
Subscriber unique identification
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32 1..65536  

name 1.3.6.1.4.1.13995.8.5.1.2
Subscriber Name
Status: current Access: read-create
OBJECT-TYPE    
  DisplayString Size(0..32)  

ipAddress 1.3.6.1.4.1.13995.8.5.1.3
Subscriber IP address
Status: current Access: read-create
OBJECT-TYPE    
  IpAddress  

macAddress 1.3.6.1.4.1.13995.8.5.1.4
Subscriber MAC address
Status: current Access: read-create
OBJECT-TYPE    
  DisplayString Size(0..17)  

serviceClass 1.3.6.1.4.1.13995.8.5.1.5
Subscriber Server Class
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER none(0), classA(1), classB(2), classC(3), classD(4)  

rowStatus 1.3.6.1.4.1.13995.8.5.1.6
A special field used to create new rows.
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

upstreamDownstreamRatio 1.3.6.1.4.1.13995.8.6
Upstream bandwidth to downstream bandwidth ratio
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(1..32)  

qosStatus 1.3.6.1.4.1.13995.8.7
Enable or disable status of Qos
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

afe 1.3.6.1.4.1.13995.9
OBJECT IDENTIFIER    

afeExtractor 1.3.6.1.4.1.13995.9.1
OBJECT IDENTIFIER    

afeExtTxGain 1.3.6.1.4.1.13995.9.1.1
afeExtTxGain
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

afeExtRxGain 1.3.6.1.4.1.13995.9.1.2
afeExtRxGain
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

afeExtDownstream 1.3.6.1.4.1.13995.9.1.3
afeExtDownstream
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(3..4)  

afeExtUpstream 1.3.6.1.4.1.13995.9.1.4
afeExtUpstream
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(3..4)  

afeExtActivate 1.3.6.1.4.1.13995.9.1.5
afeExtActivate
Status: current Access: read-write
OBJECT-TYPE    
  TruthValue  

afeInjector 1.3.6.1.4.1.13995.9.2
OBJECT IDENTIFIER    

afeInjTxGain 1.3.6.1.4.1.13995.9.2.1
afeInjTxGain
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

afeInjRxGain 1.3.6.1.4.1.13995.9.2.2
afeInjRxGain
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

afeInjDownstream 1.3.6.1.4.1.13995.9.2.3
afeInjDownstream
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(3..4)  

afeInjUpstream 1.3.6.1.4.1.13995.9.2.4
afeInjUpstream
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(3..4)  

afeInjActivate 1.3.6.1.4.1.13995.9.2.5
afeInjActivate
Status: current Access: read-write
OBJECT-TYPE    
  TruthValue  

amperionRoutes 1.3.6.1.4.1.13995.10
OBJECT IDENTIFIER    

amperionRouteTable 1.3.6.1.4.1.13995.10.1
This entity's IP Routing table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AmperionRouteEntry

amperionRouteEntry 1.3.6.1.4.1.13995.10.1.1
Row of table amperionRouteTable
Status: current Access: not-accessible
OBJECT-TYPE    
  AmperionRouteEntry  

ipRouteDest 1.3.6.1.4.1.13995.10.1.1.1
The destination IP address of this route. An entry with a value of 0.0.0.0 is considered a default route. Multiple routes to a single destination can appear in the table, but access to such multiple entries is dependent on the table- access mechanisms defined by the network management protocol in use.
Status: current Access: read-only
OBJECT-TYPE    
  IpAddress  

ipRouteIfIndex 1.3.6.1.4.1.13995.10.1.1.2
The index value which uniquely identifies the local interface through which the next hop of this route should be reached. The interface identified by a particular value of this index is the same interface as identified by the same value of ifIndex.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

ipRouteMetric1 1.3.6.1.4.1.13995.10.1.1.3
The primary routing metric for this route. The semantics of this metric are determined by the routing-protocol specified in the route's ipRouteProto value. If this metric is not used, its value should be set to -1.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

ipRouteMetric2 1.3.6.1.4.1.13995.10.1.1.4
An alternate routing metric for this route. The semantics of this metric are determined by the routing-protocol specified in the route's ipRouteProto value. If this metric is not used, its value should be set to -1.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

ipRouteMetric3 1.3.6.1.4.1.13995.10.1.1.5
An alternate routing metric for this route. The semantics of this metric are determined by the routing-protocol specified in the route's ipRouteProto value. If this metric is not used, its value should be set to -1.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

ipRouteMetric4 1.3.6.1.4.1.13995.10.1.1.6
An alternate routing metric for this route. The semantics of this metric are determined by the routing-protocol specified in the route's ipRouteProto value. If this metric is not used, its value should be set to -1.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

ipRouteNextHop 1.3.6.1.4.1.13995.10.1.1.7
The IP address of the next hop of this route. (In the case of a route bound to an interface which is realized via a broadcast media, the value of this field is the agent's IP address on that interface.)
Status: current Access: read-write
OBJECT-TYPE    
  IpAddress  

ipRouteType 1.3.6.1.4.1.13995.10.1.1.8
The type of route. Note that the values direct(3) and indirect(4) refer to the notion of direct and indirect routing in the IP architecture. Setting this object to the value invalid(2) has the effect of invalidating the corresponding entry in the ipRouteTable object. That is, it effectively dissasociates the destination identified with said entry from the route identified with said entry. It is an implementation-specific matter as to whether the agent removes an invalidated entry from the table. Accordingly, management stations must be prepared to receive tabular information from agents that corresponds to entries not currently in use. Proper interpretation of such entries requires examination of the relevant ipRouteType object.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER other(1), invalid(2), direct(3), indirect(4)  

ipRouteProto 1.3.6.1.4.1.13995.10.1.1.9
The routing mechanism via which this route was learned. Inclusion of values for gateway routing protocols is not intended to imply that hosts should support those protocols.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER other(1), local(2), netmgt(3), icmp(4), egp(5), ggp(6), hello(7), rip(8), isis(9), esis(10), ciscoIgrp(11), bbnSpfIgp(12), ospf(13), bgp(14)  

ipRouteAge 1.3.6.1.4.1.13995.10.1.1.10
The number of seconds since this route was last updated or otherwise determined to be correct. Note that no semantics of `too old' can be implied except through knowledge of the routing protocol by which the route was learned.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

ipRouteMask 1.3.6.1.4.1.13995.10.1.1.11
Indicate the mask to be logical-ANDed with the destination address before being compared to the value in the ipRouteDest field. For those systems that do not support arbitrary subnet masks, an agent constructs the value of the ipRouteMask by determining whether the value of the correspondent ipRouteDest field belong to a class-A, B, or C network, and then using one of: mask network 255.0.0.0 class-A 255.255.0.0 class-B 255.255.255.0 class-C If the value of the ipRouteDest is 0.0.0.0 (a default route), then the mask value is also 0.0.0.0. It should be noted that all IP routing subsystems implicitly use this mechanism.
Status: current Access: read-write
OBJECT-TYPE    
  IpAddress  

ipRouteMetric5 1.3.6.1.4.1.13995.10.1.1.12
An alternate routing metric for this route. The semantics of this metric are determined by the routing-protocol specified in the route's ipRouteProto value. If this metric is not used, its value should be set to -1.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

ipRouteInfo 1.3.6.1.4.1.13995.10.1.1.13
A reference to MIB definitions specific to the particular routing protocol which is responsible for this route, as determined by the value specified in the route's ipRouteProto value. If this information is not present, its value should be set to the OBJECT IDENTIFIER { 0 0 }, which is a syntatically valid object identifier, and any conformant implementation of ASN.1 and BER must be able to generate and recognize this value.
Status: current Access: read-only
OBJECT-TYPE    
  OBJECT IDENTIFIER  

ipDefRouteActivate 1.3.6.1.4.1.13995.10.1.1.14
Command to activate the new default route.
Status: current Access: read-write
OBJECT-TYPE    
  TruthValue  

plc 1.3.6.1.4.1.13995.11
OBJECT IDENTIFIER    

plcExtractor 1.3.6.1.4.1.13995.11.1
OBJECT IDENTIFIER    

plcExtTxGain 1.3.6.1.4.1.13995.11.1.1
plcExtTxGain
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..10  

plcExtRxGain 1.3.6.1.4.1.13995.11.1.2
plcExtRxGain
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..10  

plcInjector 1.3.6.1.4.1.13995.11.2
OBJECT IDENTIFIER    

plcInjTxGain 1.3.6.1.4.1.13995.11.2.1
plcInjTxGain
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..10  

plcInjRxGain 1.3.6.1.4.1.13995.11.2.2
plcInjRxGain
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..10  

plcUp 1.3.6.1.4.1.13995.11.3
Extractor's PLC interface came up
Status: current Access: read-write
NOTIFICATION-TYPE    

plcDown 1.3.6.1.4.1.13995.11.4
Extractor's PLC interface went down
Status: current Access: read-write
NOTIFICATION-TYPE    

afeCpldResetCount 1.3.6.1.4.1.13995.11.5
afe Cpld Reset Count
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

plcLossCount 1.3.6.1.4.1.13995.11.6
plc Loss Count
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

resetCounters 1.3.6.1.4.1.13995.11.7
reset Counters
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER idle(1), reset(2)  

optimizationTable 1.3.6.1.4.1.13995.11.8
If Injector - This table contains the frequencies(channels) / gains / throughput of all the extractors down stream. If Extractor - This table should contain frequencies(channels) / gains / throughput for the the plc segment between this extractor and the injector/repeator upstream.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    OptimizationEntry

optimizationEntry 1.3.6.1.4.1.13995.11.8.1
Row of table optimizationTable
Status: current Access: not-accessible
OBJECT-TYPE    
  OptimizationEntry  

extrIpaddress 1.3.6.1.4.1.13995.11.8.1.1
extractor's ipaddress
Status: current Access: read-only
OBJECT-TYPE    
  IpAddress  

extrChannelNumber 1.3.6.1.4.1.13995.11.8.1.2
Extractor Channel Number
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

upstreamFreq 1.3.6.1.4.1.13995.11.8.1.3
Upstream Frequency
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

downstreamFreq 1.3.6.1.4.1.13995.11.8.1.4
Downstream Frequency
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

rxGain 1.3.6.1.4.1.13995.11.8.1.5
rxGain setting
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

txGain 1.3.6.1.4.1.13995.11.8.1.6
Tx Gain Setting
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

plcThroughput 1.3.6.1.4.1.13995.11.8.1.7
plcThroughput
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

upStreamDownStream 1.3.6.1.4.1.13995.11.8.1.8
This to indicate if this entry pertains to the upstream segment or the downstream segment
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER upstream(1), downstream(2), unknown(3)  

gpsInfo 1.3.6.1.4.1.13995.11.8.1.9
GPS co-ordinates. Currently this is a string which means the machine just picks up whatever GPS info is defined in it's system group and sends it to the extractor
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(1..128)  

plcEventDescription 1.3.6.1.4.1.13995.11.9
String to be sent in the plc up/down event. Will contain ip address of the unit which just went down or will say 'local system' if current system
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(1..128)  

tempGroup 1.3.6.1.4.1.13995.12
OBJECT IDENTIFIER    

tempFanState 1.3.6.1.4.1.13995.12.1
The fans may be on or off.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER off(0), on(1)  

tempFanTargetTemp 1.3.6.1.4.1.13995.12.2
The target temperature is the average temperature we would like the system to operate at if possible. It is used to calculate how long the fans should stay on during a cycle which is part of a duty cycle algorithm. Temperature is in degrees celsius.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..70  

tempEventDescription 1.3.6.1.4.1.13995.12.5
String to be sent with the temperature trap events.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(1..130)  

tempHighWarnLimitTrap 1.3.6.1.4.1.13995.12.4
The system temperature has exceeded the High Warning threshold.
Status: current Access: read-only
NOTIFICATION-TYPE    

tempHighErrorLimitTrap 1.3.6.1.4.1.13995.12.6
The system temperature has exceeded the High Error Threshold.
Status: current Access: read-only
NOTIFICATION-TYPE    

tempLowWarnLimitTrap 1.3.6.1.4.1.13995.12.7
The system temperature has gone below the Low Warning Threshold.
Status: current Access: read-only
NOTIFICATION-TYPE    

tempLowErrorLimitTrap 1.3.6.1.4.1.13995.12.8
The system temperature has gone below the Low Error Threshold.
Status: current Access: read-only
NOTIFICATION-TYPE    

tempHighWarnLimit 1.3.6.1.4.1.13995.12.3
The system temperature has exceeded a high temperature warning threshold. Temperature is in degrees Celsius.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..150  

tempHighErrorLimit 1.3.6.1.4.1.13995.12.9
The system temperature has exceeded a high temperature error threshold. Temperature is in degrees Celsius.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..150  

tempLowWarnLimit 1.3.6.1.4.1.13995.12.10
The system temperature has gone below a low temperature warning threshold. Temperature is in degrees Celscius.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 -100..60  

tempLowErrorLimit 1.3.6.1.4.1.13995.12.11
The system temperature has gone below the Low Temperature Error Threshold. The temperature is in degrees Celscius.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 -100..60  

tempHighWarnHist 1.3.6.1.4.1.13995.12.12
Hysteresis value for the High Temperature Warning Condition. Once the system temperature has reached or exceeded the High Temperature Warning threshold, it must go down to or below the Hysteresis temperature before sending the trap again. The hysteresis temperature is in degrees Celcius.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 -10..150  

tempHighErrorHist 1.3.6.1.4.1.13995.12.13
Hysteresis value for the High Temperature Error Condition. Once the system temperature has reached or exceeded the High Temperature Error Threshold, it must go down to or below the Hysteresis temperature before sending the trap again. The hysteresis temperature is in degrees Celcius.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 -10..150  

tempLowWarnHist 1.3.6.1.4.1.13995.12.14
Hysteresis value for the Low Temperature Warning Condition. Once the system temperature is less than or equal to the LowTemperature Warning threshold, it must go up to or above the Hysteresis temperature before sending the trap again. The hysteresis temperature is in degrees Celcius.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 -100..60  

tempLowErrorHist 1.3.6.1.4.1.13995.12.15
Hysteresis value for the Low Temperature Error Condition. Once the system temperature is less than or equal to the LowTemperature Error threshold, it must go up to or above the Hysteresis temperature before sending the trap again. The hysteresis temperature is in degrees Celcius.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 -100..60  

tempSystemTemp 1.3.6.1.4.1.13995.12.16
The temperature of the Main Digital Board. The temperature is obtained by reading a chip located on the digital board.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32