AirPairv2cTrap-MIB

File: AirPairv2cTrap-MIB.mib (27304 bytes)

Imported modules

SNMPv2-SMI RFC-1212 AirPair-MIB

Imported symbols

NOTIFICATION-TYPE IpAddress ifIndex
OBJECT-TYPE airPair ttySessionUserName
ttySessionUserConnectionType

Defined Values

apSnmpV2Notification 1.3.6.1.4.1.7262.1.26
OBJECT IDENTIFIER    

apSnmpV2Traps 1.3.6.1.4.1.7262.1.26.0
OBJECT IDENTIFIER    

coldStartV2c 1.3.6.1.4.1.7262.1.26.0.0
A coldStart trap signifies that the sending protocol entity is reinitializing itself such that the agent's configuration or the protocol entity implementation may be altered.
Status: current Access: read-only
NOTIFICATION-TYPE    

linkDownV2c 1.3.6.1.4.1.7262.1.26.0.1
A linkDown trap signifies that the sending protocol entity recognizes a failure in one of the communication links represented in the agent's configuration.
Status: current Access: read-only
NOTIFICATION-TYPE    

linkUpV2c 1.3.6.1.4.1.7262.1.26.0.2
A linkUp trap signifies that the sending protocol entity recognizes that one of the communication links represented in the agent's configuration has come up.
Status: current Access: read-only
NOTIFICATION-TYPE    

explicitAuthenticationFailureV2c 1.3.6.1.4.1.7262.1.26.0.3
Authentication of the peer AirPair node has failed. The severity is critical, the probable cause is an incorrect authentication configuration on AirPair faulty cable between the modem and radio, and recommended course of action is to check both ends of the link.
Status: current Access: read-only
NOTIFICATION-TYPE    

autoNegotiationDuplexMismatchV2c 1.3.6.1.4.1.7262.1.26.0.4
The AirPair ethernet interface has a mismatch in duplex. The severity is major, the probable cause is an incorrect configuration of the switch or router connected to AirPair, or the AirPair autonegotion settings. The recommended course of action is to check the connection.
Status: current Access: read-only
NOTIFICATION-TYPE    

modemLossOfSignalLockFromDemodulatorV2c 1.3.6.1.4.1.7262.1.26.0.5
Loss of signal lock from the demodulator. The severity is critical, the probable cause is lost synchronization with the far end, and recommended course of action is to check the operational state of both ends of the link.
Status: current Access: read-only
NOTIFICATION-TYPE    

modemUncorrectedBerThresholdExceededV2c 1.3.6.1.4.1.7262.1.26.0.6
The uncorrected BER threshold has been exceeded. The severity is major, the probable cause is physical interference in the air link or misalignment of the radios or severe weather conditions, and recommended course of action is to check the line of site between the air pair nodes.
Status: current Access: read-only
NOTIFICATION-TYPE    

modemModulatorPllLockFailureV2c 1.3.6.1.4.1.7262.1.26.0.7
Modulator PLL failure. The severity is critical, the probable cause a faulty modem card within AirPair, and recommended course of action is to replace the modem unit.
Status: current Access: read-only
NOTIFICATION-TYPE    

modemModulatorLossOfSyncBytesV2c 1.3.6.1.4.1.7262.1.26.0.8
Loss of sync bytes at the input of the modulator. The severity is critical, the probable cause is physical interference in the air link, and recommended course of action is to check the line of site between the air pair nodes.
Status: current Access: read-only
NOTIFICATION-TYPE    

modemModulatorInputFifoErrorV2c 1.3.6.1.4.1.7262.1.26.0.9
Overrun or underrun of the FIFO contained inside the modulator. The severity is critical, the probable cause is electrical interference, and recommended course of action is to reset the modem unit, or relpace the modem unit.
Status: current Access: read-only
NOTIFICATION-TYPE    

modemModulatorInputDataErrorV2c 1.3.6.1.4.1.7262.1.26.0.10
All ones or all zeroes at the input of the modulator. The severity is critical, the probable cause is electrical interference, and recommended course of action is to reset the modem unit, or replace the modem unit.
Status: current Access: read-only
NOTIFICATION-TYPE    

modemSnrBelowThresholdV2c 1.3.6.1.4.1.7262.1.26.0.11
The demodulator SNR performance worse than programmed levels. The severity is major, the probable cause is physical interference in the air link path or misalignment of the radios or severe weather conditions, and recommended course of action is to check the line of site between the air pair nodes.
Status: current Access: read-only
NOTIFICATION-TYPE    

radioPLDROLostLockV2c 1.3.6.1.4.1.7262.1.26.0.12
The PLDRO/LO has lost lock on the radio. The severity is critical, the probable cause a faulty radio unit within AirPair, and recommended course of action is to replace the radio unit.
Status: current Access: read-only
NOTIFICATION-TYPE    

radioLostCommunicationV2c 1.3.6.1.4.1.7262.1.26.0.13
RS232 communication lost between AIRPAIR and the radio. The severity is critical, the probable cause is a faulty cable between the modem and radio, and recommended course of action is to check the connection.
Status: current Access: read-only
NOTIFICATION-TYPE    

radioMismatchV2c 1.3.6.1.4.1.7262.1.26.0.14
The radio connected to the AIRPAIR modem does not match the frequency programmed into the modem unit. The severity is major, the probable cause is an incorrectly programmed modem or an incorrect radio type connected to the modem, and recommended course of action is to check the modem frequency settings and radio hardware version number or serial number.
Status: current Access: read-only
NOTIFICATION-TYPE    

radioPowerAmpV2c 1.3.6.1.4.1.7262.1.26.0.15
The power amplifier on the radio is not operating within normal operating specifications. The severity is critical, the probable cause a faulty radio unit within AirPair, and recommended course of action is to replace the radio unit.
Status: current Access: read-only
NOTIFICATION-TYPE    

ifTxSynthUnlockedV2c 1.3.6.1.4.1.7262.1.26.0.16
The IF card within the modem unit has a Transmit Synthesizer which is not locked and as a result will not transmit. The severity is critical, the probable cause an incorrectly programmed frequency setting in the modem or a faulty IF card, and recommended course of action is to check frequency setting in the modem or to replace the modem unit.
Status: current Access: read-only
NOTIFICATION-TYPE    

ifRxSynthUnlockedV2c 1.3.6.1.4.1.7262.1.26.0.17
The IF card within the modem unit has a Receive Synthesizer which is not locked. The severity is critical, the probable cause an incorrectly programmed frequency setting in the modem or a faulty IF card, and recommended course of action is to check frequency setting in the modem or to replace the modem unit.
Status: current Access: read-only
NOTIFICATION-TYPE    

ttySessionCommencedV2c 1.3.6.1.4.1.7262.1.26.0.18
A person has successfully gained access to the ascii management port (telnet, local management port, or HTTP). The username is included in the Trap.
Status: current Access: read-only
NOTIFICATION-TYPE    

ttySessionTerminatedV2c 1.3.6.1.4.1.7262.1.26.0.19
A person has logged out of an ascii management port (telnet, local management port, or HTTP). The username is included in the Trap.
Status: current Access: read-only
NOTIFICATION-TYPE    

rslBelowThresholdV2c 1.3.6.1.4.1.7262.1.26.0.20
The RSL has been detected below its minimum threshold.
Status: current Access: read-only
NOTIFICATION-TYPE    

droppedFramesThresholdExceededV2c 1.3.6.1.4.1.7262.1.26.0.21
The ethernet dropped frames threshold has been detected above its threshold value.
Status: current Access: read-only
NOTIFICATION-TYPE    

bwUtilizationThresholdExceededV2c 1.3.6.1.4.1.7262.1.26.0.22
The ethernet bandwidth threshold has been detected above its threshold value.
Status: current Access: read-only
NOTIFICATION-TYPE    

explicitAuthFailureClearedV2c 1.3.6.1.4.1.7262.1.26.0.23
The condition has cleared. The peer node is now authenticated.
Status: current Access: read-only
NOTIFICATION-TYPE    

autoNegDuplexMismatchClearedV2c 1.3.6.1.4.1.7262.1.26.0.24
The condition has cleared. The Ethernet connection is not experiencing auto-negotiation duplex mismatch.
Status: current Access: read-only
NOTIFICATION-TYPE    

lossOfSyncSigFromDemoClearedV2c 1.3.6.1.4.1.7262.1.26.0.25
The condition has cleared. The demodulator is synchronized.
Status: current Access: read-only
NOTIFICATION-TYPE    

uncorrectedBerThresExceededClearedV2c 1.3.6.1.4.1.7262.1.26.0.26
The condition has cleared. The demodulator uncorrected BER is now below its minimum threshold value.
Status: current Access: read-only
NOTIFICATION-TYPE    

modemModPLLFailureClearedV2c 1.3.6.1.4.1.7262.1.26.0.27
The condition has cleared. The modem PLL is not failing.
Status: current Access: read-only
NOTIFICATION-TYPE    

modemModLossOfSyncBytesClearedV2c 1.3.6.1.4.1.7262.1.26.0.28
The condition has cleared. The modem is not experiencing loss of synch bytes.
Status: current Access: read-only
NOTIFICATION-TYPE    

modemModInputFifoOverUnderClearedV2c 1.3.6.1.4.1.7262.1.26.0.29
The condition has cleared. The modem is not experiencing input FIFO over/under runs.
Status: current Access: read-only
NOTIFICATION-TYPE    

modemModInputDataInacClearedV2c 1.3.6.1.4.1.7262.1.26.0.30
The condition has cleared. The modem is not experiencing data inactivity.
Status: current Access: read-only
NOTIFICATION-TYPE    

snrBelowThresholdClearedV2c 1.3.6.1.4.1.7262.1.26.0.31
The condition has cleared. SNR is now above its minimum threshold value.
Status: current Access: read-only
NOTIFICATION-TYPE    

radioPLDROLostLockClearedV2c 1.3.6.1.4.1.7262.1.26.0.32
The condition has cleared. The radio PLDRO/LO lost lock condition has cleared.
Status: current Access: read-only
NOTIFICATION-TYPE    

radioLostCommunicationClearedV2c 1.3.6.1.4.1.7262.1.26.0.33
The condition has cleared. RS232 communication has been re-establisted between AIRPAIR and the radio.
Status: current Access: read-only
NOTIFICATION-TYPE    

radioMismatchClearedV2c 1.3.6.1.4.1.7262.1.26.0.34
The condtion has cleared. The radio matches the programmed parameters in the modem.
Status: current Access: read-only
NOTIFICATION-TYPE    

radioPowerAmpClearedV2c 1.3.6.1.4.1.7262.1.26.0.35
The condtion has cleared. The radio Power Amp is not in the failed state.
Status: current Access: read-only
NOTIFICATION-TYPE    

ifTxSynthUnlockedClearedV2c 1.3.6.1.4.1.7262.1.26.0.36
The condtion has cleared. The IF stage transmit synthesizer is now locked.
Status: current Access: read-only
NOTIFICATION-TYPE    

ifRxSynthUnlockedClearedV2c 1.3.6.1.4.1.7262.1.26.0.37
The condtion has cleared. The IF stage receive synthesizer is now locked.
Status: current Access: read-only
NOTIFICATION-TYPE    

rslBelowThresholdClearedV2c 1.3.6.1.4.1.7262.1.26.0.38
The condition has cleared. RSL is now above its minimum threshold.
Status: current Access: read-only
NOTIFICATION-TYPE    

droppedFramesThresholdExceededClearedV2c 1.3.6.1.4.1.7262.1.26.0.39
The condition has cleared.The ethernet dropped frames threshold is now below its threshold value.
Status: current Access: read-only
NOTIFICATION-TYPE    

bwUtilizationThresholdExceededClearedV2c 1.3.6.1.4.1.7262.1.26.0.40
The condition has cleared. The ethernet bandwidth threshold is now below its threshold value.
Status: current Access: read-only
NOTIFICATION-TYPE    

rxIfCableLossExceededV2c 1.3.6.1.4.1.7262.1.26.0.41
The Rx cable loss has exceeded limit. This trap is only valid when the AirPair installation type is IDU-ODU split.
Status: current Access: read-only
NOTIFICATION-TYPE    

rxIfCableLossExceededClearedV2c 1.3.6.1.4.1.7262.1.26.0.42
The condition has cleared. The Rx cable loss is now within limit. This trap is only valid when the AirPair installation type is IDU-ODU split
Status: current Access: read-only
NOTIFICATION-TYPE    

txIfCableLossExceededV2c 1.3.6.1.4.1.7262.1.26.0.43
The Tx cable loss has exceeded limit. This trap is only valid when the AirPair installation type is IDU-ODU split
Status: current Access: read-only
NOTIFICATION-TYPE    

txIfCableLossExceededClearedV2c 1.3.6.1.4.1.7262.1.26.0.44
The condition has cleared. The Tx cable loss is now within limit. This trap is only valid when the AirPair installation type is IDU-ODU split
Status: current Access: read-only
NOTIFICATION-TYPE    

fan1FailedV2c 1.3.6.1.4.1.7262.1.26.0.45
The Fan1 has failed. This trap is only valid when the AirPair installation type is IDU-ODU split
Status: current Access: read-only
NOTIFICATION-TYPE    

fan1FailedClearedV2c 1.3.6.1.4.1.7262.1.26.0.46
The condition has cleared. The fan1 is running normally. This trap is only valid when the AirPair installation type is IDU-ODU split
Status: current Access: read-only
NOTIFICATION-TYPE    

fan2FailedV2c 1.3.6.1.4.1.7262.1.26.0.47
The Fan2 has failed. This trap is only valid when the AirPair installation type is IDU-ODU split
Status: current Access: read-only
NOTIFICATION-TYPE    

fan2FailedClearedV2c 1.3.6.1.4.1.7262.1.26.0.48
The condition has cleared. The fan2 is running normally. This trap is only valid when the AirPair installation type is IDU-ODU split
Status: current Access: read-only
NOTIFICATION-TYPE    

modemCardMismatchedHardwareFirmwareV2c 1.3.6.1.4.1.7262.1.26.0.49
The modem card has incompatible hardware and firmware. The firmware will not run properly on this card.
Status: current Access: read-only
NOTIFICATION-TYPE    

modemCardMismatchedHardwareFirmwareClearedV2c 1.3.6.1.4.1.7262.1.26.0.50
The condition has cleared. The modem card has compatible hardware and firmware. The firmware will run properly on this card.
Status: current Access: read-only
NOTIFICATION-TYPE    

atpcConfigMismatchV2c 1.3.6.1.4.1.7262.1.26.0.51
ATPC configuration mismatch in the Airpair systems. ATPC is enabled at one system, but ATPC is not enabled at the other system.
Status: current Access: read-only
NOTIFICATION-TYPE    

atpcConfigMismatchClearedV2c 1.3.6.1.4.1.7262.1.26.0.52
ATPC configuration mismatch in the Airpair systems is cleared. Both systems enabled ATPC.
Status: current Access: read-only
NOTIFICATION-TYPE    

radioHiPwrOptM1V2c 1.3.6.1.4.1.7262.1.26.0.53
When hi-power radio is used, hi-power gate M1 drain current is out of lower or upper limits.
Status: current Access: read-only
NOTIFICATION-TYPE    

radioHiPwrOptM1ClearedV2c 1.3.6.1.4.1.7262.1.26.0.54
When hi-power radio is used, hi-power gate M1 drain current is between lower and upper limits.
Status: current Access: read-only
NOTIFICATION-TYPE    

radioHiPwrOptM2V2c 1.3.6.1.4.1.7262.1.26.0.55
When hi-power radio is used, hi-power gate M2 drain current is out of lower or upper limits.
Status: current Access: read-only
NOTIFICATION-TYPE    

radioHiPwrOptM2ClearedV2c 1.3.6.1.4.1.7262.1.26.0.56
When hi-power radio is used, hi-power gate M2 drain current is between lower and upper limits.
Status: current Access: read-only
NOTIFICATION-TYPE    

radioHiPwrTxDetectorV2c 1.3.6.1.4.1.7262.1.26.0.57
When hi-power radio is used, hi-power tx detector dBm value is smaller than limit.
Status: current Access: read-only
NOTIFICATION-TYPE    

radioHiPwrTxDetectorClearedV2c 1.3.6.1.4.1.7262.1.26.0.58
When hi-power radio is used, hi-power tx detector dBm value is not smaller than limit.
Status: current Access: read-only
NOTIFICATION-TYPE    

sntpServersUnreachableV2c 1.3.6.1.4.1.7262.1.26.0.59
Can't reach any of the sntp servers
Status: current Access: read-only
NOTIFICATION-TYPE    

sntpServersUnreachableClearedV2c 1.3.6.1.4.1.7262.1.26.0.60
At least one of SNTP servers is reachable
Status: current Access: read-only
NOTIFICATION-TYPE    

rlsMismatchV2c 1.3.6.1.4.1.7262.1.26.0.61
RLS mismatch
Status: current Access: read-only
NOTIFICATION-TYPE    

rlsMismatchClearedV2c 1.3.6.1.4.1.7262.1.26.0.62
RLS mismatch cleared
Status: current Access: read-only
NOTIFICATION-TYPE    

rLSShutdownActivatedV2c 1.3.6.1.4.1.7262.1.26.0.63
RLS shutdown is activated
Status: current Access: read-only
NOTIFICATION-TYPE    

rLSShutdownActivatedClearedV2c 1.3.6.1.4.1.7262.1.26.0.64
RLS shutdown is not activated
Status: current Access: read-only
NOTIFICATION-TYPE    

frequencyFileInvalidV2c 1.3.6.1.4.1.7262.1.26.0.65
When the executing frequency file is invalid, this trap is generated.
Status: current Access: read-only
NOTIFICATION-TYPE    

optionalParaNotEntFreqFileV2c 1.3.6.1.4.1.7262.1.26.0.66
when the optional parameters are not entered in frequency file, and the system boots up, this trap is generated.
Status: current Access: read-only
NOTIFICATION-TYPE    

progRadioBandNotFoundFreqFileV2c 1.3.6.1.4.1.7262.1.26.0.67
when the executing frequency file doesn't contain the info related to programmed radio band, this trap is generated.
Status: current Access: read-only
NOTIFICATION-TYPE    

redundancySwitchOverSuccessV2c 1.3.6.1.4.1.7262.1.26.0.68
Radio Redundancy Switch over success
Status: current Access: read-only
NOTIFICATION-TYPE    

redundancySwitchOverFailedV2c 1.3.6.1.4.1.7262.1.26.0.69
Radio Redundancy Switch over failed
Status: current Access: read-only
NOTIFICATION-TYPE    

redundancyNoAtpcSupportV2c 1.3.6.1.4.1.7262.1.26.0.70
Radio does not support atpc
Status: current Access: read-only
NOTIFICATION-TYPE    

redundancyNoAtpcSupportClearedV2c 1.3.6.1.4.1.7262.1.26.0.71
Radio does not support atpc cleared
Status: current Access: read-only
NOTIFICATION-TYPE    

redundancyInvalidFirmwareV2c 1.3.6.1.4.1.7262.1.26.0.72
Radio firmware on radio and on modem card mismatch
Status: current Access: read-only
NOTIFICATION-TYPE    

redundancyInvalidFirmwareClearedV2c 1.3.6.1.4.1.7262.1.26.0.73
Radio firmware mismatch cleared
Status: current Access: read-only
NOTIFICATION-TYPE    

redundancySwitchInitByLocalendV2c 1.3.6.1.4.1.7262.1.26.0.74
Radio switch initiated by local end
Status: current Access: read-only
NOTIFICATION-TYPE    

redundancySwitchInitByPeerV2c 1.3.6.1.4.1.7262.1.26.0.75
Radio switch initiated by peer
Status: current Access: read-only
NOTIFICATION-TYPE    

aamConfigMisMatchV2c 1.3.6.1.4.1.7262.1.26.0.76
Automatic Adaptive modulation configuration mismatch
Status: current Access: read-only
NOTIFICATION-TYPE    

aamConfigMisMatchClearV2c 1.3.6.1.4.1.7262.1.26.0.77
Automatic Adaptive modulation configuration mismatch cleared
Status: current Access: read-only
NOTIFICATION-TYPE    

aamQpskActiveV2c 1.3.6.1.4.1.7262.1.26.0.78
Automatic Adaptive modulation running on QPSK modulation
Status: current Access: read-only
NOTIFICATION-TYPE    

aamQpskActiveClearedV2c 1.3.6.1.4.1.7262.1.26.0.79
Automatic Adaptive modulation running on higher modulation
Status: current Access: read-only
NOTIFICATION-TYPE    

primaryRadioFaultyV2c 1.3.6.1.4.1.7262.1.26.0.80
Primary radio is faulty.
Status: current Access: read-only
NOTIFICATION-TYPE    

primaryRadioFaultyClearedV2c 1.3.6.1.4.1.7262.1.26.0.81
primary radio is not faulty anymore.
Status: current Access: read-only
NOTIFICATION-TYPE    

radioSerialNumberMismatchV2c 1.3.6.1.4.1.7262.1.26.0.82
Redundancy, Radio Serial number mismatch.
Status: current Access: read-only
NOTIFICATION-TYPE    

radioSerialNumberMismatchClearedV2c 1.3.6.1.4.1.7262.1.26.0.83
Redundancy, Radio Serial number mismatch cleared.
Status: current Access: read-only
NOTIFICATION-TYPE    

excessiveCableLossChangeV2c 1.3.6.1.4.1.7262.1.26.0.84
Excessive cable loss change
Status: current Access: read-only
NOTIFICATION-TYPE    

excessiveCableLossChangeClearedV2c 1.3.6.1.4.1.7262.1.26.0.85
Excessive cable loss change cleared
Status: current Access: read-only
NOTIFICATION-TYPE