AVICI-BAY-MIB

File: AVICI-BAY-MIB.mib (44319 bytes)

Imported modules

SNMPv2-SMI SNMPv2-TC SNMPv2-CONF
AVICI-SMI AVICI-TC AVICI-SYSTEM-MIB

Imported symbols

MODULE-IDENTITY OBJECT-TYPE Counter32
Gauge32 Integer32 TimeTicks
NOTIFICATION-TYPE DisplayString MODULE-COMPLIANCE
OBJECT-GROUP NOTIFICATION-GROUP aviciMibs
AviciVoltageType AviciHighAvailabilityType AviciBayType
AviciSlotType AviciProductIdType AviciRevisionType
AviciPartNumberType AviciSerialNumberType AviciLedValue
AviciUnitType aviciSysTrapDescr

Defined Types

AviciBayEntry  
SEQUENCE    
  aviciBayIndex AviciBayType
  aviciBayCriticalLed AviciLedValue
  aviciBayMajorLed AviciLedValue
  aviciBayMinorLed AviciLedValue
  aviciBayAlarmCutOff INTEGER
  aviciBayModTempCriticalThreshold Integer32
  aviciBayModTempMajorThreshold Integer32
  aviciBayModTempMinorThreshold Integer32
  aviciBayTempCriticalThreshold Integer32
  aviciBayTempMajorThreshold Integer32
  aviciBayTempMinorThreshold Integer32

AviciBayControllerEntry  
SEQUENCE    
  aviciBayControllerIndex INTEGER
  aviciBayControllerOperStatus INTEGER
  aviciBayControllerAdminStatus INTEGER
  aviciBayControllerPartNumber AviciPartNumberType
  aviciBayControllerSerialNumber AviciSerialNumberType
  aviciBayControllerRevision AviciRevisionType
  aviciBayControllerSoftwareVersion DisplayString
  aviciBayControllerFirmwareVersion DisplayString
  aviciBayControllerProductId AviciProductIdType
  aviciBayControllerProductSerialNumber AviciSerialNumberType
  aviciBayControllerProductRevision AviciRevisionType
  aviciBayControllerDescr DisplayString

AviciBayVoltageEntry  
SEQUENCE    
  aviciBayVoltageIndex INTEGER
  aviciBayVoltageType AviciVoltageType
  aviciBayVoltage Integer32
  aviciBayVoltageStatus INTEGER
  aviciBayVoltageDescr DisplayString

AviciBayFanEntry  
SEQUENCE    
  aviciBayFanIndex INTEGER
  aviciBayFanAdminStatus INTEGER
  aviciBayFanOperStatus INTEGER
  aviciBayFanSpeed Integer32
  aviciBayFanCurrTemp Integer32
  aviciBayFanMaxTemp Gauge32
  aviciBayFanLedStatus AviciLedValue
  aviciBayFanCurrFailures Integer32
  aviciBayFanDescr DisplayString

AviciBaySlotEntry  
SEQUENCE    
  aviciSlotIndex AviciSlotType
  aviciBaySlotStatus INTEGER
  aviciBaySlotRxOctets Counter32
  aviciBaySlotRxMessages Counter32
  aviciBaySlotRxDiscards Counter32
  aviciBaySlotRxProtoErrs Counter32
  aviciBaySlotRxIOErrs Counter32
  aviciBaySlotRxTimeouts Counter32
  aviciBaySlotTxOctets Counter32
  aviciBaySlotTxMessages Counter32
  aviciBaySlotTxDiscards Counter32
  aviciBaySlotTxProtoErrs Counter32
  aviciBaySlotTxIOErrs Counter32
  aviciBaySlotTxTimeouts Counter32

AviciBayBreakerEntry  
SEQUENCE    
  aviciBayBreakerIndex Integer32
  aviciBayBreakerType AviciHighAvailabilityType
  aviciBayBreakerStatus INTEGER
  aviciBayBreakerDescr DisplayString

AviciBayCoAlarmEntry  
SEQUENCE    
  aviciBayCoAlarmIndex INTEGER 1..65535
  aviciBayCoAlarmType INTEGER
  aviciBayCoAlarmDescr DisplayString
  aviciBayCoAlarmTime TimeTicks
  aviciBayCoAlarmUnitNum Integer32
  aviciBayCoAlarmUnitType AviciUnitType

Defined Values

aviciBayMIB 1.3.6.1.4.1.2474.1.4
The MIB module for an Avici Bay.
MODULE-IDENTITY    

aviciBayObjects 1.3.6.1.4.1.2474.1.4.1
OBJECT IDENTIFIER    

aviciBayNotifications 1.3.6.1.4.1.2474.1.4.2
OBJECT IDENTIFIER    

aviciBayControllerNotifications 1.3.6.1.4.1.2474.1.4.3
OBJECT IDENTIFIER    

aviciBayNotificationPrefix 1.3.6.1.4.1.2474.1.4.2.0
OBJECT IDENTIFIER    

aviciBayControllerNotificationPrefix 1.3.6.1.4.1.2474.1.4.3.0
OBJECT IDENTIFIER    

aviciBayTable 1.3.6.1.4.1.2474.1.4.1.1
This table contains parameters and state variables for each Avici bay.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AviciBayEntry

aviciBayEntry 1.3.6.1.4.1.2474.1.4.1.1.1
An entry containing management information for each bay.
Status: current Access: not-accessible
OBJECT-TYPE    
  AviciBayEntry  

aviciBayIndex 1.3.6.1.4.1.2474.1.4.1.1.1.1
The index number of the bay entry.
Status: current Access: read-only
OBJECT-TYPE    
  AviciBayType  

aviciBayCriticalLed 1.3.6.1.4.1.2474.1.4.1.1.1.2
The state of the Critical Led on the Bay.
Status: current Access: read-only
OBJECT-TYPE    
  AviciLedValue  

aviciBayMajorLed 1.3.6.1.4.1.2474.1.4.1.1.1.3
The state of the Major Led on the Bay.
Status: current Access: read-only
OBJECT-TYPE    
  AviciLedValue  

aviciBayMinorLed 1.3.6.1.4.1.2474.1.4.1.1.1.4
The state of the Minor Led on the Bay.
Status: current Access: read-only
OBJECT-TYPE    
  AviciLedValue  

aviciBayAlarmCutOff 1.3.6.1.4.1.2474.1.4.1.1.1.5
Central office alarms are triggered by a hardware condition. A write can only use the value off. This turns off the Central Office audible alarms.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER on(1), off(2)  

aviciBayModTempCriticalThreshold 1.3.6.1.4.1.2474.1.4.1.1.1.6
The module temperature in degrees C above which a critical alarm will be triggered.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

aviciBayModTempMajorThreshold 1.3.6.1.4.1.2474.1.4.1.1.1.7
The module temperature in degrees C above which a major alarm will be triggered.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

aviciBayModTempMinorThreshold 1.3.6.1.4.1.2474.1.4.1.1.1.8
The module temperature in degrees C above which a minor alarm will be triggered.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

aviciBayTempCriticalThreshold 1.3.6.1.4.1.2474.1.4.1.1.1.9
The incoming ambient air temperature in degrees C above which a critical alarm will be triggered.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

aviciBayTempMajorThreshold 1.3.6.1.4.1.2474.1.4.1.1.1.10
The incoming ambient air temperature in degrees C above which a major alarm will be triggered.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

aviciBayTempMinorThreshold 1.3.6.1.4.1.2474.1.4.1.1.1.11
The incoming ambient air temperature in degrees C above which a minor alarm will be triggered.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

aviciBayControllerTable 1.3.6.1.4.1.2474.1.4.1.2
This table contains parameters and state variables for the bay controller.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AviciBayControllerEntry

aviciBayControllerEntry 1.3.6.1.4.1.2474.1.4.1.2.1
A list of status and parameter values for each bay.
Status: current Access: not-accessible
OBJECT-TYPE    
  AviciBayControllerEntry  

aviciBayControllerIndex 1.3.6.1.4.1.2474.1.4.1.2.1.1
The index number of the bay controller entry.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 1..2  

aviciBayControllerOperStatus 1.3.6.1.4.1.2474.1.4.1.2.1.2
The current operational status of the bay controller.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER down(1), passive(2), active(3), failed(4)  

aviciBayControllerAdminStatus 1.3.6.1.4.1.2474.1.4.1.2.1.3
The current admin status of the bay controller.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER reboot(1), passive(2), active(3), diagnostic(4)  

aviciBayControllerPartNumber 1.3.6.1.4.1.2474.1.4.1.2.1.4
The part number of this bay controller object.
Status: current Access: read-only
OBJECT-TYPE    
  AviciPartNumberType  

aviciBayControllerSerialNumber 1.3.6.1.4.1.2474.1.4.1.2.1.5
The serial number of this bay controller object.
Status: current Access: read-only
OBJECT-TYPE    
  AviciSerialNumberType  

aviciBayControllerRevision 1.3.6.1.4.1.2474.1.4.1.2.1.6
The revision number of this bay controller object.
Status: current Access: read-only
OBJECT-TYPE    
  AviciRevisionType  

aviciBayControllerSoftwareVersion 1.3.6.1.4.1.2474.1.4.1.2.1.7
The version of the software running on this bay controller object.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

aviciBayControllerFirmwareVersion 1.3.6.1.4.1.2474.1.4.1.2.1.8
The version of the firmware running on this bay controller object.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

aviciBayControllerProductId 1.3.6.1.4.1.2474.1.4.1.2.1.9
The product identification number of this bay controller object.
Status: current Access: read-only
OBJECT-TYPE    
  AviciProductIdType  

aviciBayControllerProductSerialNumber 1.3.6.1.4.1.2474.1.4.1.2.1.10
The product serial number of this bay controller object.
Status: current Access: read-only
OBJECT-TYPE    
  AviciSerialNumberType  

aviciBayControllerProductRevision 1.3.6.1.4.1.2474.1.4.1.2.1.11
The product revision number of this bay controller object.
Status: current Access: read-only
OBJECT-TYPE    
  AviciRevisionType  

aviciBayControllerDescr 1.3.6.1.4.1.2474.1.4.1.2.1.12
A description of this bay controller object.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

aviciBayVoltageTable 1.3.6.1.4.1.2474.1.4.1.3
This table contains parameters and state variables for voltage lines and rails. Each bay contains eight voltage rails used for backplane communication.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AviciBayVoltageEntry

aviciBayVoltageEntry 1.3.6.1.4.1.2474.1.4.1.3.1
A list of status and parameter values for voltage lines and rails.
Status: current Access: not-accessible
OBJECT-TYPE    
  AviciBayVoltageEntry  

aviciBayVoltageIndex 1.3.6.1.4.1.2474.1.4.1.3.1.1
The index number of the voltage entry.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 1..18  

aviciBayVoltageType 1.3.6.1.4.1.2474.1.4.1.3.1.2
The type of the voltage entry.
Status: current Access: read-only
OBJECT-TYPE    
  AviciVoltageType  

aviciBayVoltage 1.3.6.1.4.1.2474.1.4.1.3.1.3
The current actual logical voltage of the line. The logical voltage is the mapped value reported by the AD7870 ADC for the line.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

aviciBayVoltageStatus 1.3.6.1.4.1.2474.1.4.1.3.1.4
The current state of the voltage device. If no failure has occurred, the value of this object is inSpec.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER inSpec(1), outSpec(2)  

aviciBayVoltageDescr 1.3.6.1.4.1.2474.1.4.1.3.1.5
A description of this voltage object.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

aviciBayFanTable 1.3.6.1.4.1.2474.1.4.1.4
This table contains parameters and state variables for blowers. There are up to 4 fans in a shelf installed at the bottom of each bay.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AviciBayFanEntry

aviciBayFanEntry 1.3.6.1.4.1.2474.1.4.1.4.1
A list of status and parameter values for a fan controller.
Status: current Access: not-accessible
OBJECT-TYPE    
  AviciBayFanEntry  

aviciBayFanIndex 1.3.6.1.4.1.2474.1.4.1.4.1.1
The index number of the fan entry.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 1..4  

aviciBayFanAdminStatus 1.3.6.1.4.1.2474.1.4.1.4.1.2
The current administrative status of the fan.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER offline(1), autonomous(2), controlled(3)  

aviciBayFanOperStatus 1.3.6.1.4.1.2474.1.4.1.4.1.3
The current operational status of the fan.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER offline(1), autonomous(2), controlled(3), failed(4)  

aviciBayFanSpeed 1.3.6.1.4.1.2474.1.4.1.4.1.4
The current speed of the fan in RPM.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..2700  

aviciBayFanCurrTemp 1.3.6.1.4.1.2474.1.4.1.4.1.5
The current room temp at the fan in degrees C.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

aviciBayFanMaxTemp 1.3.6.1.4.1.2474.1.4.1.4.1.6
The maximum temperature at the fan since the bay controller booted in degrees C.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

aviciBayFanLedStatus 1.3.6.1.4.1.2474.1.4.1.4.1.7
The current status of the fan's LED. off -- Fan normal red -- Fan failure green -- Fan in autonomous mode (self-controlled)
Status: current Access: read-only
OBJECT-TYPE    
  AviciLedValue  

aviciBayFanCurrFailures 1.3.6.1.4.1.2474.1.4.1.4.1.8
This variable specifies this fan object's current failures. A value of 0 means there are no current failures for this fan object. The value represents a vector of bits, each specifying a type of fan failure: - Bit 0 Communication failure - Bit 1 General failure (fan jammed, etc.) - Bit 2 Filter blocked - Bit 3 Bad or absent internal thermistor - Bit 4 Bad or absent external thermistor - Bit 5 Fan temperature above minor threshold but less than major - Bit 6 Fan temperature above major threshold but less than critical threshold - Bit 7 Fan temperature above critical threshold
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..511  

aviciBayFanDescr 1.3.6.1.4.1.2474.1.4.1.4.1.9
A description of this fan object.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

aviciBaySlotTable 1.3.6.1.4.1.2474.1.4.1.5
This table contains parameters and state variables for the slots.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AviciBaySlotEntry

aviciBaySlotEntry 1.3.6.1.4.1.2474.1.4.1.5.1
A list of status and parameter values for each module in a TSR bay.
Status: current Access: not-accessible
OBJECT-TYPE    
  AviciBaySlotEntry  

aviciSlotIndex 1.3.6.1.4.1.2474.1.4.1.5.1.1
The index number of the slot entry.
Status: current Access: read-only
OBJECT-TYPE    
  AviciSlotType  

aviciBaySlotStatus 1.3.6.1.4.1.2474.1.4.1.5.1.2
The current state of the slot.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER empty(1), occupied(2), identified(3)  

aviciBaySlotRxOctets 1.3.6.1.4.1.2474.1.4.1.5.1.3
The total number of slot octets received.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

aviciBaySlotRxMessages 1.3.6.1.4.1.2474.1.4.1.5.1.4
The number of successful slot reads.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

aviciBaySlotRxDiscards 1.3.6.1.4.1.2474.1.4.1.5.1.5
The total number of slot received messages discarded for any reason.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

aviciBaySlotRxProtoErrs 1.3.6.1.4.1.2474.1.4.1.5.1.6
The number of slot received messages discarded due to protocol error.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

aviciBaySlotRxIOErrs 1.3.6.1.4.1.2474.1.4.1.5.1.7
The number of slot received messages discarded due to I/O error.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

aviciBaySlotRxTimeouts 1.3.6.1.4.1.2474.1.4.1.5.1.8
The number of slot received messages discarded due to module timeout error.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

aviciBaySlotTxOctets 1.3.6.1.4.1.2474.1.4.1.5.1.9
The total number of slot octets sent.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

aviciBaySlotTxMessages 1.3.6.1.4.1.2474.1.4.1.5.1.10
The number of successful slot writes.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

aviciBaySlotTxDiscards 1.3.6.1.4.1.2474.1.4.1.5.1.11
The total number of slot send messages aborted for any reason.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

aviciBaySlotTxProtoErrs 1.3.6.1.4.1.2474.1.4.1.5.1.12
The number of slot send messages aborted due to protocol error.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

aviciBaySlotTxIOErrs 1.3.6.1.4.1.2474.1.4.1.5.1.13
The number of slot send messages aborted due to I/O error.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

aviciBaySlotTxTimeouts 1.3.6.1.4.1.2474.1.4.1.5.1.14
The number of slot send messages aborted due to module timeout error.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

aviciBayBreakerTable 1.3.6.1.4.1.2474.1.4.1.6
This table contains parameters and state variables for the 48-volt breakers at the top of the TSR chassis. There are 4 mains and 4 backups, one pair for each of the 4 shelves.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AviciBayBreakerEntry

aviciBayBreakerEntry 1.3.6.1.4.1.2474.1.4.1.6.1
The state and type of each breaker.
Status: current Access: not-accessible
OBJECT-TYPE    
  AviciBayBreakerEntry  

aviciBayBreakerIndex 1.3.6.1.4.1.2474.1.4.1.6.1.1
The index number of the breaker entry.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

aviciBayBreakerType 1.3.6.1.4.1.2474.1.4.1.6.1.2
The type of the breaker entry.
Status: current Access: read-only
OBJECT-TYPE    
  AviciHighAvailabilityType  

aviciBayBreakerStatus 1.3.6.1.4.1.2474.1.4.1.6.1.3
The current state of the breaker.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), open(2), closed(3)  

aviciBayBreakerDescr 1.3.6.1.4.1.2474.1.4.1.6.1.4
A description of this breaker object.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

aviciBayCoAlarmSystem 1.3.6.1.4.1.2474.1.4.1.7
OBJECT IDENTIFIER    

aviciBayCoActiveAlarmCount 1.3.6.1.4.1.2474.1.4.1.7.1
The number of current events causing central office alarms in this Avici bay. If there are no such current events, this object contains the value 0
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

aviciBayCoAlarmLastChange 1.3.6.1.4.1.2474.1.4.1.7.2
The value of sysUpTime at the time the aviciBayCoAlarmTable changed.
Status: current Access: read-only
OBJECT-TYPE    
  TimeTicks  

aviciBayCoAlarmTable 1.3.6.1.4.1.2474.1.4.1.8
This table contains any currently active central office alarms.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AviciBayCoAlarmEntry

aviciBayCoAlarmEntry 1.3.6.1.4.1.2474.1.4.1.8.1
A description of each active central office alarm.
Status: current Access: not-accessible
OBJECT-TYPE    
  AviciBayCoAlarmEntry  

aviciBayCoAlarmIndex 1.3.6.1.4.1.2474.1.4.1.8.1.1
The index of this central office alarm on this bay.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 1..65535  

aviciBayCoAlarmType 1.3.6.1.4.1.2474.1.4.1.8.1.2
The severity level of this central office alarm.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER critical(1), major(2), minor(3)  

aviciBayCoAlarmDescr 1.3.6.1.4.1.2474.1.4.1.8.1.3
A description of the event that caused this central office alarm.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

aviciBayCoAlarmTime 1.3.6.1.4.1.2474.1.4.1.8.1.4
The time this event occurred in hundreths of a second since the last time the system was rebooted.
Status: current Access: read-only
OBJECT-TYPE    
  TimeTicks  

aviciBayCoAlarmUnitNum 1.3.6.1.4.1.2474.1.4.1.8.1.5
The identification number of the failing component. If there is more than one failing component of the same unit type in a bay, then the identification number is the bay number.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

aviciBayCoAlarmUnitType 1.3.6.1.4.1.2474.1.4.1.8.1.6
The type of the failing component. If there is more than one failing component of the same unit type in a bay, for example, a fan, then this value is multipleFailures.
Status: current Access: read-only
OBJECT-TYPE    
  AviciUnitType  

aviciBayControllerColdStart 1.3.6.1.4.1.2474.1.4.3.0.1
The aviciBayControllerColdStart notification signifies that the bay controller has powered-up.
Status: current Access: read-only
NOTIFICATION-TYPE    

aviciBayControllerWarmStart 1.3.6.1.4.1.2474.1.4.3.0.2
The aviciBayControllerWarmStart notification signifies that the bay controller has been restarted.
Status: current Access: read-only
NOTIFICATION-TYPE    

aviciBayControllerDown 1.3.6.1.4.1.2474.1.4.3.0.3
The aviciBayControllerDown notification signifies that a server is no longer communicating with the bay controller after having established communication.
Status: current Access: read-only
NOTIFICATION-TYPE    

aviciBayVoltageNotification 1.3.6.1.4.1.2474.1.4.2.0.1
A Voltage notification is sent when a change is detected in the 5 volt backplane communication rails. These backplane communication rails are used by the bay controller to communicate with the occupant of a given slot. There are 8 rails, each servicing the slots in one half of a shelf in the bay (aviciBayVoltageIndex == rail): Rail Slots ============== 1 1 - 5 2 6 - 10 3 11 - 15 4 16 - 20 5 21 - 25 6 26 - 30 7 31 - 35 8 36 - 40 If the voltage is out of specification, the communication path will not function. When a given backplane communication channel is not functioning, modules serviced by this rail cannot be discovered (if a module is inserted) and will not be authorized to boot (if an existing module reboots). The current voltage is reported in the aviciBayVoltage object. A human readable description of the event triggering this notification is included in the aviciSysTrapDescr object.
Status: current Access: read-only
NOTIFICATION-TYPE    

aviciBayFanNotification 1.3.6.1.4.1.2474.1.4.2.0.2
A Fan notification is sent when the specified fan detects a fault or clears a fault. The current ambient air temperature entering the fan is reported in the aviciBayFanCurrTemp object. All existing fan faults are reported in the aviciBayFanCurrFailures object as a bitmap. If no failures exist, this object contains a 0. A human readable description of the event triggering this notification is included in the aviciSysTrapDescr object. Communication Failure: This failure indicates that the cooling module has been removed or the cooling module firmware is no longer communicating with the bay controller. If a communication failure occurs, the fans will run in autonomous mode until communication with the bay controller is reestablished. Once communication is established, the failure is cleared. General Failure: This failure indicates that the cooling module firmware is able to communicate with the bay controller and is reporting a broken fan. This could mean that the fan is burned out, jammed, or the firmware is unable to sense fan speed due to tachometer failure. When the problem is corrected, the failure is cleared. Filter Blocked: This failure indicates that the fan detected that the filter is blocked. When the obstruction is removed from the filter or the clogged air filter is replaced, this failure will clear. Bad or absent internal thermistor: This failure indicates that the fan internal thermistor is missing or is not functioning. If the thermister is not functioning, the fan cannot sense the incoming ambient air temperature. The ambient temperature is used to control fan speed in autonomous mode and when there are no modules reporting their current temperature. Bad or absent external thermistor: This failure indicates that the fan external thermistor is expected to be installed and is not functioning. Minor temperature threshold: This failure indicates that the incoming ambient air temperature is above the minor threshold temperature, but below the major threshold temperature. Either the cooling system in the building has failed, or it has insufficient cooling capacity for the equipment in the room. A rapid rise in temperature usually indicates cooling system failure whereas a slow rise usually indicates insufficient cooling capacity. When the temperature drops below the minor threshold, this failure will clear. Major temperature threshold: This failure indicates that the incoming ambient air temperature is above the major threshold temperature, but below the critical threshold temperature. Either the cooling system in the building has failed, or it has insufficient cooling capacity for the equipment in the room. A rapid rise in temperature usually indicates cooling system failure whereas a slow rise usually indicates insufficient cooling capacity. When the temperature drops below the major threshold, this failure will clear. Critical temperature threshold: This failure indicates that the incoming ambient air temperature is above the critical threshold temperature. Either the cooling system in the building has failed, or it has insufficient cooling capacity for the equipment in the room. A rapid rise in temperature usually indicates cooling system failure whereas a slow rise usually indicates insufficient cooling capacity. When the temperature drops below the critical threshold, this failure will clear.
Status: current Access: read-only
NOTIFICATION-TYPE    

aviciBayBreakerNotification 1.3.6.1.4.1.2474.1.4.2.0.3
A Breaker notification is sent when the specified breaker has tripped or been manually reset. The breaker may have tripped due to a short circuit, excessive current being drawn, or by an excessively high incoming voltage. This failure is cleared when the breaker is manually reset. If the breaker is manually opened, no trap will be sent.
Status: current Access: read-only
NOTIFICATION-TYPE    

aviciBayMultiFanFailures 1.3.6.1.4.1.2474.1.4.2.0.4
Two or more fans have failed in this bay.
Status: current Access: read-only
NOTIFICATION-TYPE    

aviciBayMultiBayControllerFailures 1.3.6.1.4.1.2474.1.4.2.0.5
Both bay controllers have failed in this bay.
Status: current Access: read-only
NOTIFICATION-TYPE    

aviciBayMIBConformance 1.3.6.1.4.1.2474.1.4.4
OBJECT IDENTIFIER    

aviciBayMIBCompliances 1.3.6.1.4.1.2474.1.4.4.1
OBJECT IDENTIFIER    

aviciBayMIBGroups 1.3.6.1.4.1.2474.1.4.4.2
OBJECT IDENTIFIER    

aviciBayMIBCompliance 1.3.6.1.4.1.2474.1.4.4.1.1
The compliance statement for the aviciBay.
Status: current Access: read-only
MODULE-COMPLIANCE    

aviciBayGroup 1.3.6.1.4.1.2474.1.4.4.2.1
Objects for the bay.
Status: current Access: read-only
OBJECT-GROUP    

aviciBayControllerGroup 1.3.6.1.4.1.2474.1.4.4.2.2
Objects for the bayController.
Status: current Access: read-only
OBJECT-GROUP    

aviciBayCentralOfficeGroup 1.3.6.1.4.1.2474.1.4.4.2.3
Objects for the central office.
Status: current Access: read-only
OBJECT-GROUP    

aviciBayNotificationGroup 1.3.6.1.4.1.2474.1.4.4.2.4
Notifications for the bay.
Status: current Access: read-only
NOTIFICATION-GROUP