ATT-CNM-DS3-MIB

File: ATT-CNM-DS3-MIB.mib (13735 bytes)

Imported modules

RFC1155-SMI RFC1213-MIB RFC-1212

Imported symbols

enterprises Gauge DisplayString
OBJECT-TYPE

Defined Types

AttCNMds3ConfigEntry  
SEQUENCE    
  attCNMds3ConfigIndex INTEGER
  attCNMds3LineType INTEGER
  attCNMds3ZeroCoding INTEGER
  attCNMds3ErrorsMaxIntervals INTEGER
  attCNMds3ErrorsIntervalLen INTEGER

AttCNMds3StatusEntry  
SEQUENCE    
  attCNMds3StatusIndex INTEGER
  attCNMds3LineStatus INTEGER

AttCNMds3ErrorsEntry  
SEQUENCE    
  attCNMds3ErrorsIndex INTEGER
  attCNMds3ErrorsInterval INTEGER
  attCNMds3ErrorsTimeStamp INTEGER
  attCNMds3ErrorsLocalTime DisplayString
  attCNMds3LCVs Gauge
  attCNMds3LESs Gauge
  attCNMds3LSESs Gauge
  attCNMds3CVs Gauge
  attCNMds3ESs Gauge
  attCNMds3SESs Gauge
  attCNMds3SEFSs Gauge
  attCNMds3UASs Gauge

Defined Values

att-2 1.3.6.1.4.1.74
OBJECT IDENTIFIER    

att-products 1.3.6.1.4.1.74.1
OBJECT IDENTIFIER    

att-mgmt 1.3.6.1.4.1.74.2
OBJECT IDENTIFIER    

att-cnmAgent 1.3.6.1.4.1.74.1.9
OBJECT IDENTIFIER    

att-cnm 1.3.6.1.4.1.74.2.15
OBJECT IDENTIFIER    

att-cnm-ds3 1.3.6.1.4.1.74.2.15.4
OBJECT IDENTIFIER    

attCNMds3ConfigTable 1.3.6.1.4.1.74.2.15.4.1
A list of entries containing configuration information for all DS3 interfaces managed by this system.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AttCNMds3ConfigEntry

attCNMds3ConfigEntry 1.3.6.1.4.1.74.2.15.4.1.1
An entry containing configuration information for a particular DS3 interface.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  AttCNMds3ConfigEntry  

attCNMds3ConfigIndex 1.3.6.1.4.1.74.2.15.4.1.1.1
A unique value for each DS3 interface. The interface identified by a particular value of this index is the same interface as identified by the same value of an attCNMifConfigIndex object instance.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

attCNMds3LineType 1.3.6.1.4.1.74.2.15.4.1.1.2
This variable indicates the variety of DS3 C-bit application supported by this interface. For SMDS, this variable will have the value ds3ClearChannel, denoting that this interface supports the clear-channel with C-bit usage unspecified as specified by ANSI.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(1), ds3M23(2), ds3SYNTRAN(3), ds3CbitParity(4), ds3ClearChannel(5)  

attCNMds3ZeroCoding 1.3.6.1.4.1.74.2.15.4.1.1.3
This variable describes the variety of zero code suppression/substitution used on the DS3 interface its characteristics.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ds3other(1), ds3B3ZS(2)  

attCNMds3ErrorsMaxIntervals 1.3.6.1.4.1.74.2.15.4.1.1.4
This variable identifies the maximum number of measurement intervals supported for the error counts maintained by this DS3 interface in the attCNMds3ErrorsTable.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

attCNMds3ErrorsIntervalLen 1.3.6.1.4.1.74.2.15.4.1.1.5
This variable identifies the number of seconds that make up one complete measurement interval for the error counts maintained by this DS3 interface in the attCNMds3ErrorsTable.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

attCNMds3StatusTable 1.3.6.1.4.1.74.2.15.4.2
A list of entries containing status information for all DS3 interfaces managed by this system.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AttCNMds3StatusEntry

attCNMds3StatusEntry 1.3.6.1.4.1.74.2.15.4.2.1
An entry containing status information for a particular DS3 interface.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  AttCNMds3StatusEntry  

attCNMds3StatusIndex 1.3.6.1.4.1.74.2.15.4.2.1.1
A unique value for each DS3 interface. The interface identified by a particular value of this index is the same interface as identified by the same value of an attCNMifConfigIndex object instance.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

attCNMds3LineStatus 1.3.6.1.4.1.74.2.15.4.2.1.2
This variable indicates the most Line Status of this interface. This object is a bit map represented as a sum, therefore, it can represent multiple failures (alarms) simultaneously. The various bit positions are: 1 No Alarm Present 2 Yellow Alarm 4 Near End Alarm-Indication-Signal 8 Near End Loss-Of-Frame 16 Near End Loss-Of-Signal For example, for an interface that has LOF and LOS outstanding, this object will have a value of 24.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

attCNMds3ErrorsTable 1.3.6.1.4.1.74.2.15.4.3
A list of entries containing protocol error counts, maintained during the specified measurement interval, for all DS3 interfaces managed by this system.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AttCNMds3ErrorsEntry

attCNMds3ErrorsEntry 1.3.6.1.4.1.74.2.15.4.3.1
An entry containing protocol error counts, maintained during the specified measurement interval, for a particular DS3 interface.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  AttCNMds3ErrorsEntry  

attCNMds3ErrorsIndex 1.3.6.1.4.1.74.2.15.4.3.1.1
A unique value for each DS3 interface. The interface identified by a particular value of this index is the same interface as identified by the same value of an attCNMifConfigIndex object instance.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

attCNMds3ErrorsInterval 1.3.6.1.4.1.74.2.15.4.3.1.2
This variable identifies the measurement interval number for which measurement is provided. It is a number between 1 and XX, where 1 identifies the most recently completed measurement interval and XX is the least recently completed measurement interval. The value of XX is specified by the attCNMds3ErrorsMaxIntervals object given in the attCNMds3ConfigTable. The maximum length of each measurement interval is specified by the attCNMds3ErrorsIntervalLen object given in the attCNMds3ConfigTable.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

attCNMds3ErrorsTimeStamp 1.3.6.1.4.1.74.2.15.4.3.1.3
The time stamp corresponding to the end of the specified measurement interval, as measured in seconds from 00:00:00 UTC (Coordinated Universal Time) January 1, 1970. Any fraction is rounded up.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

attCNMds3ErrorsLocalTime 1.3.6.1.4.1.74.2.15.4.3.1.4
The time stamp corresponding to the end of the specified measurement interval. Any fraction is rounded up. It is given as a printable ASCII string showing the local time at the end of the interval.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

attCNMds3LCVs 1.3.6.1.4.1.74.2.15.4.3.1.5
The counter associated with the number of Line Code Violations encountered by a DS3 interface during the specified measurement interval. For a B3ZS-coded signal, a Line Code Violation is the occurrence of a received bipolar violation that is not part of a zero-substitution code. For a B3ZS signal, an LCV may also include other error patterns such as: three consecutive zeros and incorrect parity. The Bipolar Violation Rate is generally viewed as approximating the Bit Error Rate.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

attCNMds3LESs 1.3.6.1.4.1.74.2.15.4.3.1.6
The counter associated with the number of Line Errored Seconds encountered by a DS3 interface during the specified measurement interval. A Line Errored Second is any second with at least one Line Code Violation.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

attCNMds3LSESs 1.3.6.1.4.1.74.2.15.4.3.1.7
The counter associated with the number of Line Severely Errored Seconds encountered by a DS3 interface during the specified measurement interval. A Line Severely Errored Second is any second with 45 or more Line Code Violations monitored at the DS3 rate.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

attCNMds3CVs 1.3.6.1.4.1.74.2.15.4.3.1.8
The counter associated with the number of Code Violations encountered by a DS3 interface during the specified measurement interval. For SMDS, a DS3 Code Violation is an occurrence of a P-bit error. Excessive Coding Violations signifies a faulty transmission line.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

attCNMds3ESs 1.3.6.1.4.1.74.2.15.4.3.1.9
The counter associated with the number of Errored Seconds encountered by a DS3 interface during the specified measurement interval. For SMDS DS3 signals, this is the number of seconds during which at least one error occurred which is a P-bit error or a Severely Errored Framing event.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

attCNMds3SESs 1.3.6.1.4.1.74.2.15.4.3.1.10
The counter associated with the number of Severely Errored Seconds encountered by a DS3 interface during the specified measurement interval. For SMDS DS3 signals, this is the number of seconds during which 44 or more P-bit errors occurred or at least one Severely Errored Framing event occurred. All Severely Errored Seconds are also counted as Errored Seconds.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

attCNMds3SEFSs 1.3.6.1.4.1.74.2.15.4.3.1.11
The counter associated with the number of Severely Errored Framing Seconds encountered by a DS3 interface during the specified measurement interval. A Severely Errored Framing Second is any second during which one or more Severely Errored Framing (SEF) events occurred. A Severely Errored Framing event is declared when 3 or more errors in 16 or fewer consecutive F-bits occur within a DS3 M-frame.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

attCNMds3UASs 1.3.6.1.4.1.74.2.15.4.3.1.12
The counter associated with the number of Unavailable Seconds encountered by a DS3 interface during the specified measurement interval. An Unavailable Second is any second during which the DS3 interface was unavailable to offer service.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge