ATI-MIB

File: ATI-MIB.mib (83747 bytes)

Imported modules

SNMPv2-SMI SNMPv2-TC RFC-1215
SNMP-REPEATER-MIB

Imported symbols

enterprises OBJECT-TYPE NetworkAddress
IpAddress Counter Gauge
TimeTicks mib-2 DisplayString
TRAP-TYPE rptrAddrTrackNewLastSrcAddress

Defined Types

MacAddress  
OCTET STRING Size(6)    

RptrNmMgrEntry  
SEQUENCE    
  rptrNmMgrIndex INTEGER
  rptrNmMgrIpAddr IpAddress

DeviceEntry  
SEQUENCE    
  deviceIndex INTEGER
  deviceQuadrant INTEGER
  deviceDescr DisplayString
  deviceObjectID OBJECT IDENTIFIER
  deviceIpAddr IpAddress
  devicePortCapacity INTEGER

GroupInfoEntry  
SEQUENCE    
  groupInfoIndex INTEGER
  groupLEDInfo OCTET STRING
  groupSegmentation INTEGER
  groupSecurity INTEGER
  groupIntruderProtection INTEGER
  groupSrcAddrLearningMode INTEGER
  groupIntruderTrap INTEGER
  groupIntruderDisable INTEGER
  groupOperStatus INTEGER
  groupDescr DisplayString
  groupObjectID OBJECT IDENTIFIER
  groupIPAddress IpAddress
  groupPortCapacity INTEGER
  groupEraseSourceAddressTable INTEGER
  groupAddSourceAddress OCTET STRING
  groupDeleteSourceAddress OCTET STRING
  groupLimitAddressPerPort INTEGER
  groupCheckPrimaryTimer INTEGER
  groupReceiveFailureTimer INTEGER
  groupCheckResampleTimer INTEGER

GroupStatEntry  
SEQUENCE    
  groupStatIndex INTEGER
  groupFCSError Counter
  groupAlignError Counter
  groupFrameTooLong Counter
  groupShortEvent Counter
  groupRunt Counter
  groupPortCollision Counter
  groupLateEvent Counter
  groupVeryLongEvent Counter
  groupDataRateMism Counter
  groupAutoPartition Counter
  groupFrames-64-127bytes Counter
  groupFrames-128-255bytes Counter
  groupFrames-256-511bytes Counter
  groupFrames-512-1023bytes Counter
  groupFrames-1024-1518bytes Counter

GroupSATEntry  
SEQUENCE    
  groupSATModule INTEGER
  groupSATIndex INTEGER
  groupSATMacAddress OCTET STRING
  groupSATPort INTEGER

AtiPortEntry  
SEQUENCE    
  atiPortGroupIndex INTEGER
  atiPortIndex INTEGER
  portName DisplayString
  portState INTEGER
  linkTest INTEGER
  altReconnection INTEGER
  polarityCorrection INTEGER
  partitionedLED INTEGER
  linkTestLED INTEGER
  polarityLED INTEGER
  portMACAddress MacAddress
  portFrames-64-127bytes Counter
  portFrames-128-255bytes Counter
  portFrames-256-511bytes Counter
  portFrames-512-1023bytes Counter
  portFrames-1024-1518bytes Counter
  portRedundantPort INTEGER
  portRedundantPosition INTEGER
  portLearningState INTEGER

FtConfig  
SEQUENCE    
  ftMaxAge INTEGER
  ftMaxRemove INTEGER
  ftMaxFilter INTEGER
  ftAgeTime INTEGER
  ftMaxPerm INTEGER
  ftForwMBcast INTEGER
  ftSecureMode INTEGER

FdbConfig  
SEQUENCE    
  ftMaxFilter INTEGER
  ftMaxPerm INTEGER
  ftForwMBcast INTEGER
  ftSecureMode INTEGER

FtEntry  
SEQUENCE    
  ftAddr OCTET STRING
  ftAge INTEGER
  ftDisp INTEGER

InterfaceErrors  
SEQUENCE    
  ifePort INTEGER
  ifeInBusErr Counter
  ifeInShortPkt Counter
  ifeInAlgError Counter
  ifeInBadSize Counter
  ifeInOverflow Counter
  ifeInCRCErr Counter
  ifeOutColl16 Counter
  ifeOutCol Counter
  ifeOutShortPkt Counter
  ifeOutUnderflow Counter
  ifeOutBusErr Counter

ForwardCounters  
SEQUENCE    
  fcPort INTEGER
  fcInOctets Counter
  fcInPkts Counter
  fcInNUcastPkts Counter
  fcForwOctets Counter
  fcForwPkts Counter
  fcFiltOctets Counter
  fcFiltPkts Counter

SystemCounters  
SEQUENCE    
  sysMemFree Counter
  sysMemAllocFail Counter
  sysMemTotAllocFail Counter
  sysMemAllocTooBig Counter
  sysMemFreeFail Counter
  sysTimeToReset Counter
  sysPanicMesg OCTET STRING
  sysResetCount Counter

StBridge  
SEQUENCE    
  stBrName DisplayString
  stBrIdent OCTET STRING
  stBrMaxAge INTEGER
  stBrHelloTime INTEGER
  stBrForwDelay INTEGER
  stBrIsRoot INTEGER
  stBrIsDesig INTEGER
  stBrSpanAddr OCTET STRING
  stBrPriority INTEGER
  stBrSTPDisabled INTEGER

StRoot  
SEQUENCE    
  stRtIdent OCTET STRING
  stRtCost INTEGER
  stRtPort INTEGER
  stRtMaxAge INTEGER
  stRtHelloTime INTEGER
  stRtForwDelay INTEGER

StPort  
SEQUENCE    
  stPrtPort INTEGER
  stPrtState INTEGER
  stPrtCost INTEGER
  stPrtIsDesig INTEGER
  stPrtIsRoot INTEGER
  stPrtDesigRoot OCTET STRING
  stPrtDesigCost INTEGER
  stPrtDesigBridge OCTET STRING
  stPrtDesigPort INTEGER
  stPrtPriority INTEGER

SpanTreeStats  
SEQUENCE    
  stsPort INTEGER
  stsPortDisable Counter
  stsPortEnable Counter
  stsInBadLen Counter
  stsInUnknown Counter
  stsIn8021Man Counter
  stsInConfig Counter
  stsOutConfig Counter
  stsOutTopoChg Counter

StpGenStats  
SEQUENCE    
  stsTopoChanges Counter
  stsConfigTimeout Counter

FilterRangeEntry  
SEQUENCE    
  frIndex INTEGER
  frEntry OCTET STRING

Defined Values

alliedTelesyn 1.3.6.1.4.1.207
OBJECT IDENTIFIER    

products 1.3.6.1.4.1.207.1
OBJECT IDENTIFIER    

bridge 1.3.6.1.4.1.207.1.1
OBJECT IDENTIFIER    

repeater 1.3.6.1.4.1.207.1.2
OBJECT IDENTIFIER    

atiBridgeagent 1.3.6.1.4.1.207.1.1.1
OBJECT IDENTIFIER    

bridgesnmpd 1.3.6.1.4.1.207.1.1.1.1
OBJECT IDENTIFIER    

atiBridge 1.3.6.1.4.1.207.1.1.1.1.1
OBJECT IDENTIFIER    

filterTable 1.3.6.1.4.1.207.2
OBJECT IDENTIFIER    

spanningTree 1.3.6.1.4.1.207.6
OBJECT IDENTIFIER    

mibObject 1.3.6.1.4.1.207.8
OBJECT IDENTIFIER    

atiTrapAttrs 1.3.6.1.4.1.207.9
OBJECT IDENTIFIER    

hub3600 1.3.6.1.4.1.207.1.2.1
OBJECT IDENTIFIER    

hub3100 1.3.6.1.4.1.207.1.2.10
OBJECT IDENTIFIER    

hubTurboStack 1.3.6.1.4.1.207.1.2.65
OBJECT IDENTIFIER    

hubMib 1.3.6.1.4.1.207.8.1
OBJECT IDENTIFIER    

rptrInfo 1.3.6.1.4.1.207.8.1.1
OBJECT IDENTIFIER    

groupInfo 1.3.6.1.4.1.207.8.1.2
OBJECT IDENTIFIER    

portInfo 1.3.6.1.4.1.207.8.1.3
OBJECT IDENTIFIER    

rptrStat 1.3.6.1.4.1.207.8.1.4
OBJECT IDENTIFIER    

groupStat 1.3.6.1.4.1.207.8.1.5
OBJECT IDENTIFIER    

groupSAT 1.3.6.1.4.1.207.8.1.6
OBJECT IDENTIFIER    

actualIPAddr 1.3.6.1.4.1.207.8.1.1.1
The actual IP Address that is currently being used by the hub. This could be the same value as hubIPAddr, or it may be different if another IP Address was received via Bootp.
Status: mandatory Access: read-only
OBJECT-TYPE    
  IpAddress  

hubIPAddr 1.3.6.1.4.1.207.8.1.1.2
The configured IP Address of the hub.
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

subnetMask 1.3.6.1.4.1.207.8.1.1.3
Subnet mask of the hub.
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

routerAddr 1.3.6.1.4.1.207.8.1.1.4
Gateway/router address of the hub.
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

snmpManager 1.3.6.1.4.1.207.8.1.1.5
IP Address of the hub's SNMP manager to which Traps will be sent.
Status: deprecated Access: read-write
OBJECT-TYPE    
  IpAddress  

softwareProduct 1.3.6.1.4.1.207.8.1.1.6
The ATI software product model number running in the hub.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

softwareLevel 1.3.6.1.4.1.207.8.1.1.7
The software release level running in the hub.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

configurationChanged 1.3.6.1.4.1.207.8.1.1.8
A flag, set to the value changed(1) when any of the hub's status or configuration has been changed. When this object is read, then the value is reset to nochange(2).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER changed(1), nochange(2)  

rptrNmMgrTable 1.3.6.1.4.1.207.8.1.1.9
A list of SNMP Trap Manager stations Entries. The number of entries is given by the rptrNmMgrTotal mib object.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    RptrNmMgrEntry

rptrNmMgrEntry 1.3.6.1.4.1.207.8.1.1.9.1
An Trap receipt Manager Entry containing ipaddress of the configured NMS's to which Traps are sent.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  RptrNmMgrEntry  

rptrNmMgrIndex 1.3.6.1.4.1.207.8.1.1.9.1.1
The Index of SNMP Managers IP Address.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..4  

rptrNmMgrIpAddr 1.3.6.1.4.1.207.8.1.1.9.1.2
The IP Address of the NMS host configured.
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

deviceTable 1.3.6.1.4.1.207.8.1.1.10
The table contains the mapping of all devices in the chassis. For all hubs and switches, the object 'deviceQuadrant' returns 'right' (1). For docking devices, then it will reflect the position of the device in the docking station. This object is specific to Turbo Stack.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    DeviceEntry

deviceEntry 1.3.6.1.4.1.207.8.1.1.10.1
The device entry in the DeviceTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  DeviceEntry  

deviceIndex 1.3.6.1.4.1.207.8.1.1.10.1.1
The Slot number in the chassis where the device is installed.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..8  

deviceQuadrant 1.3.6.1.4.1.207.8.1.1.10.1.2
The Quadrant of the device.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER right(1), left(2)  

deviceDescr 1.3.6.1.4.1.207.8.1.1.10.1.3
TurboStack product family only. A textual description of the device. For devices that are repeaters, this value is identical to the rptrGroupDescr object.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

deviceObjectID 1.3.6.1.4.1.207.8.1.1.10.1.4
TurboStack product family only. The sysObject identification of the device. For devices that are repeaters, this value is identical to the rptrGroupObjectID object.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OBJECT IDENTIFIER  

deviceIpAddr 1.3.6.1.4.1.207.8.1.1.10.1.5
TurboStack product family only. The IP address (if present) of the device. For hubs devices, this object will return the same value as hubIPAddr.
Status: mandatory Access: read-only
OBJECT-TYPE    
  IpAddress  

devicePortCapacity 1.3.6.1.4.1.207.8.1.1.10.1.6
TurboStack product family only. The number of ports contained within the device. Valid range is 1-1024. Within each device, the ports are uniquely numbered in the range from 1 to devicePortCapacity. For devices that are repeaters, this value is identical to the rptrGroupPortCapacity object.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..1024  

localOmegaState 1.3.6.1.4.1.207.8.1.1.11
This object enables the Local Omega to be enabled or disabled.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

remoteOmegaState 1.3.6.1.4.1.207.8.1.1.12
This object enables the Remote Omega to be enabled or disabled.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

hubReadableFrames 1.3.6.1.4.1.207.8.1.4.1
The sum total of the Readable Frames Counters of all ports on all modules/groups
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

hubReadableOctets 1.3.6.1.4.1.207.8.1.4.2
The sum total of the Readable Octets (bytes) Counters of all ports on all modules/groups
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

hubFCSError 1.3.6.1.4.1.207.8.1.4.3
The sum total of the FCS (CRC) Error Counters of all ports on all modules/groups
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

hubAlignError 1.3.6.1.4.1.207.8.1.4.4
The sum total of the Alignment Error Counters of all ports on all modules/groups
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

hubFrameTooLong 1.3.6.1.4.1.207.8.1.4.5
The sum total of the Frame Too Long Error Counters of all ports on all modules/groups
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

hubShortEvent 1.3.6.1.4.1.207.8.1.4.6
The sum total of the Short Event Error Counters of all ports on all modules/groups
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

hubRunt 1.3.6.1.4.1.207.8.1.4.7
The sum total of the Runt Error Counters of all ports on all modules/groups
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

hubLateEvent 1.3.6.1.4.1.207.8.1.4.8
The sum total of the Late Event Error Counters of all ports on all modules/groups
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

hubVeryLongEvent 1.3.6.1.4.1.207.8.1.4.9
The sum total of the Very Long Event Error (Jabber) Counters of all ports on all modules/groups
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

hubDataRateMism 1.3.6.1.4.1.207.8.1.4.10
The sum total of the Data Rate Mismatch Error Counters of all ports on all modules/groups
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

hubAutoPartition 1.3.6.1.4.1.207.8.1.4.11
The sum total of the Auto Port Partition Counters of all ports on all modules/groups
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

hubTotalError 1.3.6.1.4.1.207.8.1.4.12
The sum total of all Error Counters of all ports on all modules/groups
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

hubPortCollision 1.3.6.1.4.1.207.8.1.4.13
The sum total of the Port Collision Counters of all ports on all modules/groups
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

hubFrames-64-127bytes 1.3.6.1.4.1.207.8.1.4.14
TurboStack product family only. The sum total number of readable frames received on all ports on all modules/groups, where the frame length was in the range 64 through 127 octets.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

hubFrames-128-255bytes 1.3.6.1.4.1.207.8.1.4.15
TurboStack product family only. The sum total number of readable frames received on all ports on all modules/groups, where the frame length was in the range 128 through 255 octets.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

hubFrames-256-511bytes 1.3.6.1.4.1.207.8.1.4.16
TurboStack product family only. The sum total number of readable frames received on all ports on all modules/groups, where the frame length was in the range 256 through 511 octets.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

hubFrames-512-1023bytes 1.3.6.1.4.1.207.8.1.4.17
TurboStack product family only. The sum total number of readable frames received on all ports on all modules/groups, where the frame length was in the range 512 through 1023 octets.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

hubFrames-1024-1518bytes 1.3.6.1.4.1.207.8.1.4.18
TurboStack product family only. The sum total number of readable frames received on all ports on all modules/groups, where the frame length was in the range 1024 through 1518 octets.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

ledInfo 1.3.6.1.4.1.207.8.1.2.1
See groupLEDInfo
Status: deprecated Access: read-only
OBJECT-TYPE    
  OCTET STRING  

groupInfoTable 1.3.6.1.4.1.207.8.1.2.2
Table of group specific information.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    GroupInfoEntry

groupInfoEntry 1.3.6.1.4.1.207.8.1.2.2.1
An entry in the table, containing information about a single group of ports.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  GroupInfoEntry  

groupInfoIndex 1.3.6.1.4.1.207.8.1.2.2.1.1
This object identifies the group within the repeater for which this entry contains information.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..1024  

groupLEDInfo 1.3.6.1.4.1.207.8.1.2.2.1.2
This information encodes the current state of the module per-port LEDs.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

groupSegmentation 1.3.6.1.4.1.207.8.1.2.2.1.3
AT-3100 product family only. This object controls the segmentation option for this group. It may be segmented, connected, or using the module's external segmentation switch.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER segmented(1), connected(2), external(3)  

groupSecurity 1.3.6.1.4.1.207.8.1.2.2.1.4
AT-3100 product family only. This object controls the Security option for this group. It may be enabled, disabled, or using module's external security switch.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2), external(3)  

groupIntruderProtection 1.3.6.1.4.1.207.8.1.2.2.1.5
AT-3100 and TurboStack product families only. This object controls the Intruder Protection option for this group/module. For TurboStack products, disabled turns off Intruder Protection and places the module into source address Learning Mode. Enabled turns on Intruder Protection and places the module into Secure Mode.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

groupSrcAddrLearningMode 1.3.6.1.4.1.207.8.1.2.2.1.6
AT-3100 product family only. This object indicates the Source Address Learning Mode. Mode1 : Automatic; passive devices: Automatic MAC address learning. Re-learn port MAC address after a port is disabled/re-enabled. Passive devices connected to a port will see all backbone traffic. Mode2 : Automatic; passive devices: Automatic MAC address learning. Re-learn port MAC address after link test fails (cable removed). Passive devices connected to a port will see all backbone traffic. Mode3 : Manual: No automatic MAC address learning (disabled). Mode4 : Automatic; active devices: Automatic MAC address learning. Re-learn port MAC address after a port is disabled/re-enabled. Passive devices connected to a port will see no backbone traffic.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER mode1(1), mode2(2), mode3(3), mode4(4)  

groupIntruderTrap 1.3.6.1.4.1.207.8.1.2.2.1.7
AT-3100 and TurboStack product families only. This object controls the action to be taken by this group/module when an Intruder Alert event occurs. When this option is enabled, the detection of an intruder (a received packet with an unlearned or undefined source address) causes a Trap to be sent to the configured host manager. When this option is disabled then no Trap is sent on an Intruder Alert event.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

groupIntruderDisable 1.3.6.1.4.1.207.8.1.2.2.1.8
AT-3100 and TurboStack product families only. This object controls the action to be taken by this group/module when an Intruder Alert event occurs. When this option is enabled, the detection of an intruder (a received packet with an unlearned or undefined source address) causes the port where the intruder was detected to be automatically disabled. When this option is disabled then the port will not be disabled on an Intruder Alert event.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

groupOperStatus 1.3.6.1.4.1.207.8.1.2.2.1.9
TurboStack product family only. An object that indicates the operational status of the module. For modules that are repeaters, this value is identical to the rptrGroupOperStatus object. A status of operational(2) indicates that the module is present and functional within the chassis. A status of malfunctioning(3) indicates that the module is present within the chassis but is not functional. A status of notPresent(4) indicates that the module is temporarily or permanently physically and/or logically not a part of the chassis.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER operational(2), malfunctioning(3), notPresent(4)  

groupDescr 1.3.6.1.4.1.207.8.1.2.2.1.10
TurboStack product family only. A textual description of the module. For modules that are repeaters, this value is identical to the rptrGroupDescr object.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

groupObjectID 1.3.6.1.4.1.207.8.1.2.2.1.11
TurboStack product family only. The sysObject identification of the module. For modules that are repeaters, this value is identical to the rptrGroupObjectID object.
Status: deprecated Access: read-only
OBJECT-TYPE    
  OBJECT IDENTIFIER  

groupIPAddress 1.3.6.1.4.1.207.8.1.2.2.1.12
TurboStack product family only. The IP address (if any) of the module. For modules that are repeaters, this value is identical to the actualIPAddr object. For non-repeater modules, this object identifies the IP address that may be used to communicate directly with the module.
Status: deprecated Access: read-only
OBJECT-TYPE    
  IpAddress  

groupPortCapacity 1.3.6.1.4.1.207.8.1.2.2.1.13
TurboStack product family only. The number of ports contained within the module. Valid range range is 1-1024. Within each module, the ports are uniquely numbered in the range from 1 to groupPortCapacity. For modules that are repeaters, this value is identical to the rptrGroupPortCapacity object.
Status: deprecated Access: read-only
OBJECT-TYPE    
  INTEGER 1..1024  

groupEraseSourceAddressTable 1.3.6.1.4.1.207.8.1.2.2.1.14
TurboStack product family only. This object, when Set to the erase value, will clear (empty) the module Source Address Table, deleting all learned MAC addresses; this object will then automatically revert back to the noerase state. When Set to noerase, no action is taken and the Source Address Table remains unmodified. A Get of this object will always return the noerase value.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER noerase(1), erase(2)  

groupAddSourceAddress 1.3.6.1.4.1.207.8.1.2.2.1.15
TurboStack product family only. This object, when Set with a 48-bit MAC address value, will add the new MAC address to the module Source Address Table. A Get of this object will return a string of length zero.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(6)  

groupDeleteSourceAddress 1.3.6.1.4.1.207.8.1.2.2.1.16
TurboStack product family only. This object, when Set with a 48-bit MAC address value, will delete the MAC address from the module Source Address Table. A Get of this object will return a string of length zero.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(6)  

groupLimitAddressPerPort 1.3.6.1.4.1.207.8.1.2.2.1.17
TurboStack product family only. This object configures the module to allow no limitation on number of source addresses on its ports, or limit to only 1 source address per port.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER noLimit(1), limit1Address(2)  

groupCheckPrimaryTimer 1.3.6.1.4.1.207.8.1.2.2.1.18
TurboStack product family only. The Check Primary Timer is the timer value in seconds which determines how long to wait before checking if the primary port could receive again. This timer applies when the secondary port is enabled, and the primary port's failure is NOT due to loss of link. Range: 1 - 65535 in seconds, 0 means don't check receives. Default is 60 seconds.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..65535  

groupReceiveFailureTimer 1.3.6.1.4.1.207.8.1.2.2.1.19
TurboStack product family only. The Receive Failure Timer is the timer value in seconds which determines how long to wait before the secondary port takes over when the primary port is not receiving data. This timer applies only when the primary port's failure is NOT due to loss of link. Range: 0 - 65535 in seconds, 0 means don't check receives. Default is 60 seconds.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..65535  

groupCheckResampleTimer 1.3.6.1.4.1.207.8.1.2.2.1.20
TurboStack product family only. The Resample Timer is the timer value in milliseconds which determines how long to sample/test if the primary port could receive data or is no longer partitioned. This timer begins once groupCheckPrimaryTimer has expired, and during this sampling time, the secondary port cannot repeat data. Range: 100 - 65535 milliseconds. Default is 200 milliseconds.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 100..65535  

groupStatTable 1.3.6.1.4.1.207.8.1.5.1
Table of performance and error statistics for the groups.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    GroupStatEntry

groupStatEntry 1.3.6.1.4.1.207.8.1.5.1.1
An entry in the table, containing total performance and error statistics for a single group. Regular retrieval of the information in this table provides a means of tracking the performance and health of the networked devices attached to this group's ports. The counters in this table are redundant in the sense that they are the summations of information already available through other objects. However, these sums provide a considerable optimization of network management traffic over the otherwise necessary retrieval of the individual counters included in each sum.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  GroupStatEntry  

groupStatIndex 1.3.6.1.4.1.207.8.1.5.1.1.1
This object identifies the group within the repeater for which this entry contains information.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..1024  

groupFCSError 1.3.6.1.4.1.207.8.1.5.1.1.2
The sum total of the FCS (CRC) Error Counters of all ports on this module/group
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

groupAlignError 1.3.6.1.4.1.207.8.1.5.1.1.3
The sum total of the Alignment Error Counters of all ports on this module/group
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

groupFrameTooLong 1.3.6.1.4.1.207.8.1.5.1.1.4
The sum total of the Frame Too Long Error Counters of all ports on this module/group
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

groupShortEvent 1.3.6.1.4.1.207.8.1.5.1.1.5
The sum total of the Short Event Error Counters of all ports on this module/group
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

groupRunt 1.3.6.1.4.1.207.8.1.5.1.1.6
The sum total of the Runt Error Counters of all ports on this module/group
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

groupPortCollision 1.3.6.1.4.1.207.8.1.5.1.1.7
The sum total of the Port Collision Counters of all ports on this module/group
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

groupLateEvent 1.3.6.1.4.1.207.8.1.5.1.1.8
The sum total of the Late Event Error Counters of all ports on this module/group
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

groupVeryLongEvent 1.3.6.1.4.1.207.8.1.5.1.1.9
The sum total of the Very Long Event Error (Jabber) Counters of all ports on this module/group
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

groupDataRateMism 1.3.6.1.4.1.207.8.1.5.1.1.10
The sum total of the Data Rate Mismatch Error Counters of all ports on this module/group
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

groupAutoPartition 1.3.6.1.4.1.207.8.1.5.1.1.11
The sum total of the Auto Port Partition Counters of all ports on this module/group
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

groupFrames-64-127bytes 1.3.6.1.4.1.207.8.1.5.1.1.12
TurboStack product family only. The sum total number of readable frames received on all ports on this module/group, where the frame length was in the range 64 through 127 octets.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

groupFrames-128-255bytes 1.3.6.1.4.1.207.8.1.5.1.1.13
TurboStack product family only. The sum total number of readable frames received on all ports on this module/group, where the frame length was in the range 128 through 255 octets.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

groupFrames-256-511bytes 1.3.6.1.4.1.207.8.1.5.1.1.14
TurboStack product family only. The sum total number of readable frames received on all ports on this module/group, where the frame length was in the range 256 through 511 octets.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

groupFrames-512-1023bytes 1.3.6.1.4.1.207.8.1.5.1.1.15
TurboStack product family only. The sum total number of readable frames received on all ports on this module/group, where the frame length was in the range 512 through 1023 octets.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

groupFrames-1024-1518bytes 1.3.6.1.4.1.207.8.1.5.1.1.16
TurboStack product family only. The sum total number of readable frames received on all ports on this module/group, where the frame length was in the range 1024 through 1518 octets.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

groupSourceAddressTable 1.3.6.1.4.1.207.8.1.6.1
TurboStack product family only. Table of learned and/or configured source MAC addresses which defines the only valid and allowable source addresses for this module (if Intruder Protection is enabled).
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    GroupSATEntry

groupSATEntry 1.3.6.1.4.1.207.8.1.6.1.1
TurboStack product family only. An entry in the Source Address Table, containing information about a single source MAC address.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  GroupSATEntry  

groupSATModule 1.3.6.1.4.1.207.8.1.6.1.1.1
TurboStack product family only. This object identifies the group within the repeater for which this entry contains information.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..1024  

groupSATIndex 1.3.6.1.4.1.207.8.1.6.1.1.2
TurboStack product family only. This object identifies the index within the Source Address Table for which this entry contains information.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..1024  

groupSATMacAddress 1.3.6.1.4.1.207.8.1.6.1.1.3
TurboStack product family only. This object is the learned or configured source MAC address. If no MAC address has been learned for this table entry (if this is beyond the logical end of the table) then a string of zero length will be returned.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(6)  

groupSATPort 1.3.6.1.4.1.207.8.1.6.1.1.4
TurboStack product family only. This object is the port number where the source MAC address was last detected. If the MAC address has not been detected since the system was last started, then this object will be zero.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..1024  

atiPortTable 1.3.6.1.4.1.207.8.1.3.1
Table of descriptive and status information about the ports.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AtiPortEntry

atiPortEntry 1.3.6.1.4.1.207.8.1.3.1.1
An entry in the table, containing information about a single port.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  AtiPortEntry  

atiPortGroupIndex 1.3.6.1.4.1.207.8.1.3.1.1.1
This object identifies the group containing the port for which this entry contains information.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..1024  

atiPortIndex 1.3.6.1.4.1.207.8.1.3.1.1.2
This object identifies the port within the group for which this entry contains information. This value can never be greater than rptrGroupPortCapacity for the associated group.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..1024  

portName 1.3.6.1.4.1.207.8.1.3.1.1.3
Port Name
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..255)  

portState 1.3.6.1.4.1.207.8.1.3.1.1.4
Port State option: enabled allow repeating of packets through the port; disabled turns off the port and prevents packets repeating through the port.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2), enabledByRedund(3), disabledByRedund(4)  

linkTest 1.3.6.1.4.1.207.8.1.3.1.1.5
Link Test option: enabled turns on checking for link test signals for the port; disabled turns off checking for link test signals.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

altReconnection 1.3.6.1.4.1.207.8.1.3.1.1.6
Reconnection Method: 1=IEEE Standard, 2=Alternate.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER standardIEEE(1), alternate(2)  

polarityCorrection 1.3.6.1.4.1.207.8.1.3.1.1.7
Polarity Correction option: enabled turns on automatic polarity correction for the port; disabled turns off automatic polarity correction.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

partitionedLED 1.3.6.1.4.1.207.8.1.3.1.1.8
This object reflects the current actual partitioning state of the port. The notpartitioned value means that the port is operational and repeating through the port is enabled. The partitioned value means that the port is not operational and repeating through the port is disabled.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER notpartitioned(1), partitioned(2)  

linkTestLED 1.3.6.1.4.1.207.8.1.3.1.1.9
This object reflects the current actual link test state of the port. The nolinktesterror value means that valid link integrity test signals have been detected on the port, indicating that an operable device is cabled to the port. The linktesterror value means that no link integrity test signals have been detected, indicating removal or failure of the port-to-device cable, or that the device is not operational. This object applies only to UTP (twisted pair) and fiber optic ports (not AUI or BNC ports).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER nolinktesterror(1), linktesterror(2)  

polarityLED 1.3.6.1.4.1.207.8.1.3.1.1.10
This object reflects the current actual polarity state of the port. The notreversed value means that the port-to-device cable connection is properly polarized. The reversed value means that the cable connection has reversed polarity. This object applies only to UTP (twisted pair) and fiber optic ports (not AUI or BNC ports).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER notreversed(1), reversed(2)  

portMACAddress 1.3.6.1.4.1.207.8.1.3.1.1.11
AT-3100 product family only. This object is either the MAC address of the last readable frame (i.e., counted by rptrMonitorPortReadableFrames) received by this port, or a manually input MAC address. If neither of those exists, then a string of length zero is returned. If a 'read' operation is performed on this object, the value it returns is the same as the value returned by object 'rptrAddrTrackNewLastSrcAddress' in the Standard Repeater MIB (RFC1516).
Status: mandatory Access: read-write
OBJECT-TYPE    
  MacAddress  

portFrames-64-127bytes 1.3.6.1.4.1.207.8.1.3.1.1.12
TurboStack product family only. The number of readable frames received on this port where the frame length was in the range 64 through 127 octets.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

portFrames-128-255bytes 1.3.6.1.4.1.207.8.1.3.1.1.13
TurboStack product family only. The number of readable frames received on this port where the frame length was in the range 128 through 255 octets.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

portFrames-256-511bytes 1.3.6.1.4.1.207.8.1.3.1.1.14
TurboStack product family only. The number of readable frames received on this port where the frame length was in the range 256 through 511 octets.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

portFrames-512-1023bytes 1.3.6.1.4.1.207.8.1.3.1.1.15
TurboStack product family only. The number of readable frames received on this port where the frame length was in the range 512 through 1023 octets.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

portFrames-1024-1518bytes 1.3.6.1.4.1.207.8.1.3.1.1.16
TurboStack product family only. The number of readable frames received on this port where the frame length was in the range 1024 through 1518 octets.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

portRedundantPort 1.3.6.1.4.1.207.8.1.3.1.1.17
TurboStack product family only. This is the redundant port for atiPortIndex. If the port is a secondary port as indicated in portRedundantPosition, then it serves as a backup port. This would indicate paired ports with redundant link.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

portRedundantPosition 1.3.6.1.4.1.207.8.1.3.1.1.18
TurboStack product family only. This object will retrieve the redundant position of the port, primary or secondary port, if the port has a redundant link to it.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER primary(1), secondary(2), notapplicable(3)  

portLearningState 1.3.6.1.4.1.207.8.1.3.1.1.19
TurboStack product family only. This object enable the learning on a port to be shut ON or OFF. Once the learning is Shut Off, the learning of MAC Address will stop.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

atiTrapIntruderMacAddress 1.3.6.1.4.1.207.9.1
The Mac address of the Intruder which is different from the rfc1516 object rptrAddrTrackLastSourceAddress is seen on port which is the the next object
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  OCTET STRING Size(6)  

atiTrapIntruderModuleNumber 1.3.6.1.4.1.207.9.2
This is the module number on which an intruder was seen.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  INTEGER  

atiTrapIntruderPortNumber 1.3.6.1.4.1.207.9.3
This is the port number on which an intruder was seen.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  INTEGER  

atiPortChangeDirection 1.3.6.1.4.1.207.9.4
This is the direction of redundant port change. These two values are used in the trap atiRedundantPortChangeTrap.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  INTEGER primarytosecondary(1), secondarytoprimary(2)  

intruderProtectionTrap 20
This trap is replaced by atiIntruderProtectionTrap starting from firmware ver 3.0. AT-3100 and TurboStack product families only. This trap is sent when an Intruder Alert occurs on a port due to a received packet with an unauthorized source MAC address. Intruder Protection for the module must be enabled. The varBind list contains the MAC address of the intruder.
TRAP-TYPE    

atiIntruderProtectionTrap 21
AT-3100 and TurboStack product families only. This trap is sent when an Intruder Alert occurs on a module/port due to a received packet with an unauthorized source MAC address. Intruder Protection for the module must be enabled. The varBind list contains the module number, port number, and the MAC address of the intruder.
TRAP-TYPE    

atiRedundantPortChangeTrap 22
TurboStack product family only. This trap is sent when ports, which are configured for redundant links, change from primary to secondary or secondary to primary.
TRAP-TYPE    

ftConfig 1.3.6.1.4.1.207.2.1
Bridge FT operational parameters
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FtConfig

ftMaxAge 1.3.6.1.4.1.207.2.1.1
Seconds before an unreferenced dynamic FT entry is removed
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ftMaxRemove 1.3.6.1.4.1.207.2.1.2
Max number table entries removed each time table overflows
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

ftMaxFilter 1.3.6.1.4.1.207.2.1.3
Max number FT entries
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ftAgeTime 1.3.6.1.4.1.207.2.1.4
Seconds between FT table entries
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

ftMaxPerm 1.3.6.1.4.1.207.2.1.5
Max number of permanent FT entries. May be set to zero which causes all non-system FT entries to be deleted
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

ftForwMBcast 1.3.6.1.4.1.207.2.1.6
Flag indicates if multicast (including broadcast) packets are to be forwarded (1) or discarded (0)
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER forwardmulticast(1), filtermulticast(0)  

ftSecureMode 1.3.6.1.4.1.207.2.1.7
Flag indicates if bridge will learn addresses
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER staticaddr(1), dynamicaddr(0)  

ftEntry 1.3.6.1.4.1.207.2.2
Bridge FT entries each selected by destination address
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FtEntry

ftAddr 1.3.6.1.4.1.207.2.2.91
destination address (dummy index)
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  OCTET STRING Size(6)  

ftAge 1.3.6.1.4.1.207.2.2.1
FT entry age since last referenced in seconds
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ftDisp 1.3.6.1.4.1.207.2.2.2
FT entry disposition. Can be more than one OR'ed together
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER dynamicForwardP1(4), dynamicForwardP2(8), dynamicFlood(16), dynamicDiscard(32), staticForwardP1(5), staticForwardP2(9), staticFlood(17), staticDiscard(33), sysSendup(67), sysDiscard(35), sysFlood(83)  

interfaceErrors 1.3.6.1.4.1.207.3
Set of Ethernet link level errors
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  InterfaceErrors  

ifePort 1.3.6.1.4.1.207.3.91
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  INTEGER port1(1), port2(2)  

ifeInBusErr 1.3.6.1.4.1.207.3.1
Number of EtherStar read bus errors that have occurred
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

ifeInShortPkt 1.3.6.1.4.1.207.3.2
Number of short packets received
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

ifeInAlgError 1.3.6.1.4.1.207.3.3
Number of packets received with alignment errors
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

ifeInBadSize 1.3.6.1.4.1.207.3.4
Number of packets received greater than 1518 bytes
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

ifeInOverflow 1.3.6.1.4.1.207.3.5
Number of times receive buffer overflowed
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

ifeInCRCErr 1.3.6.1.4.1.207.3.6
Number of CRC errors detected
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

ifeOutColl16 1.3.6.1.4.1.207.3.7
Number of packets discarded due to excessive collisions
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

ifeOutCol 1.3.6.1.4.1.207.3.8
Number of collisions detected
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

ifeOutShortPkt 1.3.6.1.4.1.207.3.9
Number of short packets transmitted
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

ifeOutUnderflow 1.3.6.1.4.1.207.3.10
Number of packets transmitted w/programmed length > buffered transmitted data
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

ifeOutBusErr 1.3.6.1.4.1.207.3.11
Number of EtherStar write bus errors
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

forwardCounters 1.3.6.1.4.1.207.4
Counters associated with bridge entity
Status: mandatory Access: read-only
OBJECT-TYPE    
  ForwardCounters  

fcPort 1.3.6.1.4.1.207.4.91
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  INTEGER  

fcInOctets 1.3.6.1.4.1.207.4.1
Number bytes received by bridge entity on specified port
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fcInPkts 1.3.6.1.4.1.207.4.2
Number packets received by bridge entity on specified port
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fcInNUcastPkts 1.3.6.1.4.1.207.4.3
Number multicast/broadcast packets received by bridge enity on specified port
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fcForwOctets 1.3.6.1.4.1.207.4.4
Number bytes forwarded by bridge entity onto specified port
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fcForwPkts 1.3.6.1.4.1.207.4.5
Number of packets forwarded by bridge enity onto specified port
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fcFiltOctets 1.3.6.1.4.1.207.4.6
Number of bytes received on specified port that were discarded by bridge enity
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fcFiltPkts 1.3.6.1.4.1.207.4.7
Number of packets dicarded by filtering by bridge enity
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

systemCounters 1.3.6.1.4.1.207.5
System operating s/w counters
Status: mandatory Access: read-only
OBJECT-TYPE    
  SystemCounters  

sysMemFree 1.3.6.1.4.1.207.5.1
Number of buffers of a particular size on the memory free list
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

sysMemAllocFail 1.3.6.1.4.1.207.5.2
Number of allocation failures for a particular buffer size
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

sysMemTotAllocFail 1.3.6.1.4.1.207.5.3
Total number of memory allocation failures
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

sysMemAllocTooBig 1.3.6.1.4.1.207.5.4
Number of memory allocation requests that failed
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

sysMemFreeFail 1.3.6.1.4.1.207.5.5
Number of memory free requests that failed
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

sysTimeToReset 1.3.6.1.4.1.207.5.6
Number of seconds unit bridge reset
Status: mandatory Access: read-write
OBJECT-TYPE    
  Counter  

sysPanicMesg 1.3.6.1.4.1.207.5.7
Error message associated with last s/w generated reset
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

sysResetCount 1.3.6.1.4.1.207.5.8
Number of times bridge has been reset other than power on/off
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

stBridge 1.3.6.1.4.1.207.6.1
Bridge specific parameters related to operation of Spanning Tree Protocol
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    StBridge

stBrName 1.3.6.1.4.1.207.6.1.1
Comment string denoting the bridge
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString  

stBrIdent 1.3.6.1.4.1.207.6.1.2
802.1 Bridge ID
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

stBrMaxAge 1.3.6.1.4.1.207.6.1.3
802.1 Max BPDU Age (sec) for bridge
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

stBrHelloTime 1.3.6.1.4.1.207.6.1.4
802.1 Hello Time (sec) for bridge
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

stBrForwDelay 1.3.6.1.4.1.207.6.1.5
802.1 Forward Delay Time (sec) for bridge
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

stBrIsRoot 1.3.6.1.4.1.207.6.1.6
Bridge is root (1=yes 0=no)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER isroot(1), notroot(0)  

stBrIsDesig 1.3.6.1.4.1.207.6.1.7
Flag indicating status of bridge as designated bridge (1=yes 0=no)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER isdesigbridge(1), notdesigbridge(0)  

stBrSpanAddr 1.3.6.1.4.1.207.6.1.8
MAC address used as Spanning Tree Protocol multicast address
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

stBrPriority 1.3.6.1.4.1.207.6.1.9
802.1 bridge priority
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

stBrSTPDisabled 1.3.6.1.4.1.207.6.1.10
Variable to enable/disable operation of Spanning Tree (1=STP on 0=STP off)
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER stpdisabled(1), stpenable(0)  

stRoot 1.3.6.1.4.1.207.6.2
Parameters related to operation of Spanning Tree Protocol for Root bridge
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    StRoot

stRtIdent 1.3.6.1.4.1.207.6.2.1
802.1 Bridge ID of current Root bridge
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

stRtCost 1.3.6.1.4.1.207.6.2.2
802.1 Root Path Cost of current Root bridge
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

stRtPort 1.3.6.1.4.1.207.6.2.3
Port number of port that provides path to current Root bridge
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER rootport1(1), roorport2(2)  

stRtMaxAge 1.3.6.1.4.1.207.6.2.4
802.1 Max BPDU Age specified by current known Root bridge
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

stRtHelloTime 1.3.6.1.4.1.207.6.2.5
802.1 Hello Time specified by current Root bridge
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

stRtForwDelay 1.3.6.1.4.1.207.6.2.6
802.1 Forward Delay specified by current Root bridge
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

stPort 1.3.6.1.4.1.207.6.3
Port specific parameters related to operation of Spanning Tree Protocol
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    StPort

stPrtPort 1.3.6.1.4.1.207.6.3.91
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  INTEGER port1(1), port2(2)  

stPrtState 1.3.6.1.4.1.207.6.3.1
802.1 Port State disable and blocked states
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER disabled(0), blocked(1), listen(2), learn(4), forward(8)  

stPrtCost 1.3.6.1.4.1.207.6.3.2
802.1 Port Path Cost
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

stPrtIsDesig 1.3.6.1.4.1.207.6.3.3
Status of port as designated port for LAN
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER isDesig(1), notDesig(0)  

stPrtIsRoot 1.3.6.1.4.1.207.6.3.4
Status of port as Root Port
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER isRoot(1), notRoot(0)  

stPrtDesigRoot 1.3.6.1.4.1.207.6.3.5
Bridge ID of Root brigde
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

stPrtDesigCost 1.3.6.1.4.1.207.6.3.6
Path Cost to Root bridge as advertised by the designated bridge
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

stPrtDesigBridge 1.3.6.1.4.1.207.6.3.7
Bridge ID of designated bridge
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

stPrtDesigPort 1.3.6.1.4.1.207.6.3.8
Port ID of designated port
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

stPrtPriority 1.3.6.1.4.1.207.6.3.9
802.1 Port Priority
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

spanTreeStats 1.3.6.1.4.1.207.6.4
Spanning Tree stats on counters
Status: mandatory Access: read-only
OBJECT-TYPE    
  SEQUENCE OF  
    SpanTreeStats

stsPort 1.3.6.1.4.1.207.6.4.91
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  INTEGER  

stsTopoChanges 1.3.6.1.4.1.207.6.4.1
Number of topology changes that have occured since power-on
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

stsConfigTimeout 1.3.6.1.4.1.207.6.4.2
Number of timeouts due to config BPDU not received
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

stsPortDisable 1.3.6.1.4.1.207.6.4.3
Number of times port has been disabled since power-on
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

stsPortEnable 1.3.6.1.4.1.207.6.4.4
Number of times port has been enabled since power-on
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

stsInBadLen 1.3.6.1.4.1.207.6.4.5
Number of STP frames received with bad lenth by this port
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

stsInUnknown 1.3.6.1.4.1.207.6.4.6
Packets received with bad 802.3 LSAP number by this port
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

stsIn8021Man 1.3.6.1.4.1.207.6.4.7
Packets received with 802.1 Management LSAP (discarded)
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

stsInConfig 1.3.6.1.4.1.207.6.4.8
Number of config BPDUs received by this port
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

stsOutConfig 1.3.6.1.4.1.207.6.4.9
Number of config BPDUs transmitted by this port
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

stsOutTopoChg 1.3.6.1.4.1.207.6.4.10
Number of Topology Change Notification BPDU transmitted by this port
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

filterRange 1.3.6.1.4.1.207.7
OBJECT IDENTIFIER    

frNumRange 1.3.6.1.4.1.207.7.1
The maximum number of filter range table entries when read (GET). Set to zero to delete all filter range table entries. A set with any other value is ignored.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

frEntry 1.3.6.1.4.1.207.7.2
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  SEQUENCE OF  
    OCTET STRING

frIndex 1.3.6.1.4.1.207.7.91
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  INTEGER