AT-PLUGGABLE-DIAGNOSTICS-MIB

File: AT-PLUGGABLE-DIAGNOSTICS-MIB.mib (23741 bytes)

Imported modules

AT-SMI-MIB AT-SYSINFO-MIB SNMPv2-SMI
IF-MIB

Imported symbols

DisplayStringUnsized sysinfo Integer32
OBJECT-TYPE MODULE-IDENTITY InterfaceIndex

Defined Types

AtPluggableDiagTempEntry  
SEQUENCE    
  atPluggableDiagTempIfIndex InterfaceIndex
  atPluggableDiagTempChannel Integer32
  atPluggableDiagTempStatusReading Integer32
  atPluggableDiagTempCurrentAlarm OCTET STRING
  atPluggableDiagTempAlarmMax Integer32
  atPluggableDiagTempAlarmMin Integer32
  atPluggableDiagTempCurrentWarning OCTET STRING
  atPluggableDiagTempWarningMax Integer32
  atPluggableDiagTempWarningMin Integer32

AtPluggableDiagVccEntry  
SEQUENCE    
  atPluggableDiagVccIfIndex InterfaceIndex
  atPluggableDiagVccChannel Integer32
  atPluggableDiagVccStatusReading Integer32
  atPluggableDiagVccCurrentAlarm OCTET STRING
  atPluggableDiagVccAlarmMax Integer32
  atPluggableDiagVccAlarmMin Integer32
  atPluggableDiagVccCurrentWarning OCTET STRING
  atPluggableDiagVccWarningMax Integer32
  atPluggableDiagVccWarningMin Integer32

AtPluggableDiagTxBiasEntry  
SEQUENCE    
  atPluggableDiagTxBiasIfIndex InterfaceIndex
  atPluggableDiagTxBiasChannel Integer32
  atPluggableDiagTxBiasStatusReading Integer32
  atPluggableDiagTxBiasCurrentAlarm OCTET STRING
  atPluggableDiagTxBiasAlarmMax Integer32
  atPluggableDiagTxBiasAlarmMin Integer32
  atPluggableDiagTxBiasCurrentWarning OCTET STRING
  atPluggableDiagTxBiasWarningMax Integer32
  atPluggableDiagTxBiasWarningMin Integer32

AtPluggableDiagTxPowerEntry  
SEQUENCE    
  atPluggableDiagTxPowerIfIndex InterfaceIndex
  atPluggableDiagTxPowerChannel Integer32
  atPluggableDiagTxPowerStatusReading Integer32
  atPluggableDiagTxPowerCurrentAlarm OCTET STRING
  atPluggableDiagTxPowerAlarmMax Integer32
  atPluggableDiagTxPowerAlarmMin Integer32
  atPluggableDiagTxPowerCurrentWarning OCTET STRING
  atPluggableDiagTxPowerWarningMax Integer32
  atPluggableDiagTxPowerWarningMin Integer32

AtPluggableDiagRxPowerEntry  
SEQUENCE    
  atPluggableDiagRxPowerIfIndex InterfaceIndex
  atPluggableDiagRxPowerChannel Integer32
  atPluggableDiagRxPowerStatusReading Integer32
  atPluggableDiagRxPowerCurrentAlarm OCTET STRING
  atPluggableDiagRxPowerAlarmMax Integer32
  atPluggableDiagRxPowerAlarmMin Integer32
  atPluggableDiagRxPowerCurrentWarning OCTET STRING
  atPluggableDiagRxPowerWarningMax Integer32
  atPluggableDiagRxPowerWarningMin Integer32

AtPluggableDiagRxLosEntry  
SEQUENCE    
  atPluggableDiagRxLosIfIndex InterfaceIndex
  atPluggableDiagRxLosChannel Integer32
  atPluggableDiagRxLosStatusReading OCTET STRING

Defined Values

atPluggableDiag 1.3.6.1.4.1.207.8.4.4.3.28
The AT Pluggbale Diagnostics MIB contains objects to retrieve the standard diagnostic information from installed SFP modules.
MODULE-IDENTITY    

atPluggableDiagTable 1.3.6.1.4.1.207.8.4.4.3.28.1
OBJECT IDENTIFIER    

atPluggableDiagTempTable 1.3.6.1.4.1.207.8.4.4.3.28.1.1
A table of information regarding the various temperature parameters observed as a part of Digital diagnostics monitoring, for all the optical pluggables installed in the devices.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AtPluggableDiagTempEntry

atPluggableDiagTempEntry 1.3.6.1.4.1.207.8.4.4.3.28.1.1.1
The information about various temperature parameters of pluggables such as current status reading, current alarm status, higher and lower alarm threshold, current warning, higher and lower warning threshold.
Status: current Access: not-accessible
OBJECT-TYPE    
  AtPluggableDiagTempEntry  

atPluggableDiagTempIfIndex 1.3.6.1.4.1.207.8.4.4.3.28.1.1.1.1
The ifindex of the pluggable.
Status: current Access: not-accessible
OBJECT-TYPE    
  InterfaceIndex  

atPluggableDiagTempChannel 1.3.6.1.4.1.207.8.4.4.3.28.1.1.1.2
The channel number of the pluggable.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 1..16  

atPluggableDiagTempStatusReading 1.3.6.1.4.1.207.8.4.4.3.28.1.1.1.3
The current temperature status reading.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atPluggableDiagTempCurrentAlarm 1.3.6.1.4.1.207.8.4.4.3.28.1.1.1.4
The current temperature alarm reading.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

atPluggableDiagTempAlarmMax 1.3.6.1.4.1.207.8.4.4.3.28.1.1.1.5
The maximum temperature alarm threshold value.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atPluggableDiagTempAlarmMin 1.3.6.1.4.1.207.8.4.4.3.28.1.1.1.6
The minimum temperature alarm threshold value.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atPluggableDiagTempCurrentWarning 1.3.6.1.4.1.207.8.4.4.3.28.1.1.1.7
The current temperature warnings.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

atPluggableDiagTempWarningMax 1.3.6.1.4.1.207.8.4.4.3.28.1.1.1.8
The maximum temperature warning threshold value.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atPluggableDiagTempWarningMin 1.3.6.1.4.1.207.8.4.4.3.28.1.1.1.9
The minimum temperature warning threshold value.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atPluggableDiagVccTable 1.3.6.1.4.1.207.8.4.4.3.28.1.2
A table of information regarding the various Voltage (Vcc) parameters observed as a part of Digital diagnostics monitoring, for all the optical pluggables installed in the devices.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AtPluggableDiagVccEntry

atPluggableDiagVccEntry 1.3.6.1.4.1.207.8.4.4.3.28.1.2.1
The information about various Voltage (Vcc) parameters of pluggables such as current status reading, current alarm status, higher and lower alarm threshold, current warning, higher and lower warning threshold.
Status: current Access: not-accessible
OBJECT-TYPE    
  AtPluggableDiagVccEntry  

atPluggableDiagVccIfIndex 1.3.6.1.4.1.207.8.4.4.3.28.1.2.1.1
The ifindex of the pluggable.
Status: current Access: not-accessible
OBJECT-TYPE    
  InterfaceIndex  

atPluggableDiagVccChannel 1.3.6.1.4.1.207.8.4.4.3.28.1.2.1.2
The channel number of the pluggable.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 1..16  

atPluggableDiagVccStatusReading 1.3.6.1.4.1.207.8.4.4.3.28.1.2.1.3
The current Voltage (Vcc) status reading.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atPluggableDiagVccCurrentAlarm 1.3.6.1.4.1.207.8.4.4.3.28.1.2.1.4
The current Voltage (Vcc) alarm reading.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

atPluggableDiagVccAlarmMax 1.3.6.1.4.1.207.8.4.4.3.28.1.2.1.5
The maximum Voltage (Vcc) alarm threshold value.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atPluggableDiagVccAlarmMin 1.3.6.1.4.1.207.8.4.4.3.28.1.2.1.6
The minimum Voltage (Vcc) alarm threshold value.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atPluggableDiagVccCurrentWarning 1.3.6.1.4.1.207.8.4.4.3.28.1.2.1.7
The current Voltage (Vcc) warnings.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

atPluggableDiagVccWarningMax 1.3.6.1.4.1.207.8.4.4.3.28.1.2.1.8
The maximum Voltage (Vcc) warning threshold value.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atPluggableDiagVccWarningMin 1.3.6.1.4.1.207.8.4.4.3.28.1.2.1.9
The minimum Voltage (Vcc) warning threshold value.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atPluggableDiagTxBiasTable 1.3.6.1.4.1.207.8.4.4.3.28.1.3
A table of information regarding the various Tx Bias Current (mA) parameters observed as a part of Digital diagnostics monitoring, for all the optical pluggables installed in the devices.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AtPluggableDiagTxBiasEntry

atPluggableDiagTxBiasEntry 1.3.6.1.4.1.207.8.4.4.3.28.1.3.1
The information about various Tx Bias Current (mA) parameters of pluggables such as current status reading, current alarm status, higher and lower alarm threshold, current warning, higher and lower warning threshold.
Status: current Access: not-accessible
OBJECT-TYPE    
  AtPluggableDiagTxBiasEntry  

atPluggableDiagTxBiasIfIndex 1.3.6.1.4.1.207.8.4.4.3.28.1.3.1.1
The ifindex of the pluggable.
Status: current Access: not-accessible
OBJECT-TYPE    
  InterfaceIndex  

atPluggableDiagTxBiasChannel 1.3.6.1.4.1.207.8.4.4.3.28.1.3.1.2
The channel number of the pluggable.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 1..16  

atPluggableDiagTxBiasStatusReading 1.3.6.1.4.1.207.8.4.4.3.28.1.3.1.3
The current Tx Bias (mA) status reading.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atPluggableDiagTxBiasCurrentAlarm 1.3.6.1.4.1.207.8.4.4.3.28.1.3.1.4
The current Tx Bias (mA) alarm reading.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

atPluggableDiagTxBiasAlarmMax 1.3.6.1.4.1.207.8.4.4.3.28.1.3.1.5
The maximum Tx Bias (mA) alarm threshold value.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atPluggableDiagTxBiasAlarmMin 1.3.6.1.4.1.207.8.4.4.3.28.1.3.1.6
The minimum Tx Bias (mA) alarm threshold value.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atPluggableDiagTxBiasCurrentWarning 1.3.6.1.4.1.207.8.4.4.3.28.1.3.1.7
The current Tx Bias (mA) warnings.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

atPluggableDiagTxBiasWarningMax 1.3.6.1.4.1.207.8.4.4.3.28.1.3.1.8
The maximum Tx Bias (mA) warning threshold value.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atPluggableDiagTxBiasWarningMin 1.3.6.1.4.1.207.8.4.4.3.28.1.3.1.9
The minimum Tx Bias (mA) warning threshold value.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atPluggableDiagTxPowerTable 1.3.6.1.4.1.207.8.4.4.3.28.1.4
A table of information regarding the various Tx Power (mW) parameters observed as a part of Digital diagnostics monitoring, for all the optical pluggables installed in the devices.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AtPluggableDiagTxPowerEntry

atPluggableDiagTxPowerEntry 1.3.6.1.4.1.207.8.4.4.3.28.1.4.1
The information about various Tx Power (mW) parameters of pluggables such as current status reading, current alarm status, higher and lower alarm threshold, current warning, higher and lower warning threshold.
Status: current Access: not-accessible
OBJECT-TYPE    
  AtPluggableDiagTxPowerEntry  

atPluggableDiagTxPowerIfIndex 1.3.6.1.4.1.207.8.4.4.3.28.1.4.1.1
The ifindex of the pluggable.
Status: current Access: not-accessible
OBJECT-TYPE    
  InterfaceIndex  

atPluggableDiagTxPowerChannel 1.3.6.1.4.1.207.8.4.4.3.28.1.4.1.2
The channel number of the pluggable.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 1..16  

atPluggableDiagTxPowerStatusReading 1.3.6.1.4.1.207.8.4.4.3.28.1.4.1.3
The current Tx Power (mW) status reading.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atPluggableDiagTxPowerCurrentAlarm 1.3.6.1.4.1.207.8.4.4.3.28.1.4.1.4
The current Tx Power (mW) alarm reading.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

atPluggableDiagTxPowerAlarmMax 1.3.6.1.4.1.207.8.4.4.3.28.1.4.1.5
The maximum Tx Power (mW) alarm threshold value.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atPluggableDiagTxPowerAlarmMin 1.3.6.1.4.1.207.8.4.4.3.28.1.4.1.6
The minimum Tx Power (mW) alarm threshold value.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atPluggableDiagTxPowerCurrentWarning 1.3.6.1.4.1.207.8.4.4.3.28.1.4.1.7
The current Tx Power (mW) warnings.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

atPluggableDiagTxPowerWarningMax 1.3.6.1.4.1.207.8.4.4.3.28.1.4.1.8
The maximum Tx Power (mW) warning threshold value.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atPluggableDiagTxPowerWarningMin 1.3.6.1.4.1.207.8.4.4.3.28.1.4.1.9
The minimum Tx Power (mW) warning threshold value.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atPluggableDiagRxPowerTable 1.3.6.1.4.1.207.8.4.4.3.28.1.5
A table of information regarding the various Rx Power (mW) parameters observed as a part of Digital diagnostics monitoring, for all the optical pluggables installed in the devices.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AtPluggableDiagRxPowerEntry

atPluggableDiagRxPowerEntry 1.3.6.1.4.1.207.8.4.4.3.28.1.5.1
The information about various Rx Power (mW) parameters of pluggables such as current status reading, current alarm status, higher and lower alarm threshold, current warning, higher and lower warning threshold.
Status: current Access: not-accessible
OBJECT-TYPE    
  AtPluggableDiagRxPowerEntry  

atPluggableDiagRxPowerIfIndex 1.3.6.1.4.1.207.8.4.4.3.28.1.5.1.1
The ifindex of the pluggable.
Status: current Access: not-accessible
OBJECT-TYPE    
  InterfaceIndex  

atPluggableDiagRxPowerChannel 1.3.6.1.4.1.207.8.4.4.3.28.1.5.1.2
The channel number of the pluggable.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 1..16  

atPluggableDiagRxPowerStatusReading 1.3.6.1.4.1.207.8.4.4.3.28.1.5.1.3
The current Rx Power (mW) status reading.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atPluggableDiagRxPowerCurrentAlarm 1.3.6.1.4.1.207.8.4.4.3.28.1.5.1.4
The current Rx Power (mW) alarm reading.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

atPluggableDiagRxPowerAlarmMax 1.3.6.1.4.1.207.8.4.4.3.28.1.5.1.5
The maximum Rx Power (mW) alarm threshold value.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atPluggableDiagRxPowerAlarmMin 1.3.6.1.4.1.207.8.4.4.3.28.1.5.1.6
The minimum Rx Power (mW) alarm threshold value.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atPluggableDiagRxPowerCurrentWarning 1.3.6.1.4.1.207.8.4.4.3.28.1.5.1.7
The current Rx Power (mW) warnings.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

atPluggableDiagRxPowerWarningMax 1.3.6.1.4.1.207.8.4.4.3.28.1.5.1.8
The maximum Rx Power (mW) warning threshold value.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atPluggableDiagRxPowerWarningMin 1.3.6.1.4.1.207.8.4.4.3.28.1.5.1.9
The minimum Rx Power (mW) warning threshold value.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atPluggableDiagRxLosTable 1.3.6.1.4.1.207.8.4.4.3.28.1.6
A table of information regarding the Rx Loss of Singal (Los) parameters observed as a part of Digital diagnostics monitoring, for all the optical pluggables installed in the devices.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AtPluggableDiagRxLosEntry

atPluggableDiagRxLosEntry 1.3.6.1.4.1.207.8.4.4.3.28.1.6.1
The information about various Rx Loss of Singal (Los) parameters of pluggables such as current status reading.
Status: current Access: not-accessible
OBJECT-TYPE    
  AtPluggableDiagRxLosEntry  

atPluggableDiagRxLosIfIndex 1.3.6.1.4.1.207.8.4.4.3.28.1.6.1.1
The ifindex of the pluggable.
Status: current Access: not-accessible
OBJECT-TYPE    
  InterfaceIndex  

atPluggableDiagRxLosChannel 1.3.6.1.4.1.207.8.4.4.3.28.1.6.1.2
The channel number of the pluggable.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 1..16  

atPluggableDiagRxLosStatusReading 1.3.6.1.4.1.207.8.4.4.3.28.1.6.1.3
The current Rx Los status reading.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING