ASKEY-HARDWARE-INFORMATION-MIB

File: ASKEY-HARDWARE-INFORMATION-MIB.mib (13773 bytes)

Imported modules

SNMPv2-SMI ASKEY-DSLAM-MIB SNMPv2-TC
ASKEY-ENTITY-ALARM-MIB IF-MIB

Imported symbols

OBJECT-TYPE Integer32 Unsigned32
MODULE-IDENTITY ipDslam DisplayString
aeAlarmPhysicalIndex ifIndex

Defined Types

AskeyHwInfoEntry  
SEQUENCE    
  askeyHwInfoType INTEGER
  askeyHwSensorId INTEGER
  askeyHwSensorDescription DisplayString
  askeyHwValue INTEGER
  askeyHwRefValue INTEGER
  askeyHwValueThreshholdLow INTEGER
  askeyHwValueThreshholdHigh INTEGER

GbicModuleTableEntry  
SEQUENCE    
  gbicIdentifier INTEGER
  gbicConnector INTEGER
  gbicTransceiver Unsigned32
  gbicEncoding INTEGER
  gbicBrNominal INTEGER
  gbicLength9um INTEGER
  gbicLength50um INTEGER
  gbicLength62-5um INTEGER
  gbicCopperLength INTEGER
  gbicVendorName DisplayString
  gbicVendorOUI Unsigned32
  gbicVendorPN DisplayString
  gbicVendorSN Unsigned32
  gbicLaserWaveLength INTEGER

Defined Values

askeyHwInfo 1.3.6.1.4.1.3646.1300.2.15
This Mib describs with the information of network card, line card and fan module.
MODULE-IDENTITY    

askeyHwInfoTable 1.3.6.1.4.1.3646.1300.2.15.1
This table describes the information and the limit of voltage and temperature about network card, line card and fan tray.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AskeyHwInfoEntry

askeyHwInfoEntry 1.3.6.1.4.1.3646.1300.2.15.1.1
Tok_String
Status: current Access: not-accessible
OBJECT-TYPE    
  AskeyHwInfoEntry  

askeyHwInfoType 1.3.6.1.4.1.3646.1300.2.15.1.1.1
This object describes the measure value about rotation speed of fan, voltage or temperature of the equipment include network card, line card, and fan tray.
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER fanspeed(1), voltage(2), temperature(3)  

askeyHwSensorId 1.3.6.1.4.1.3646.1300.2.15.1.1.2
This object describes the index that mapping to the sensor of the hardware device: on the network card, there is 1 max6652; on the line card, there are 2 max6652s with 8 sensor, and each chip has 4 sensors to measure the voltage.
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER  

askeyHwSensorDescription 1.3.6.1.4.1.3646.1300.2.15.1.1.3
This object describes the sensor on the nc or lc
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

askeyHwValue 1.3.6.1.4.1.3646.1300.2.15.1.1.4
This object describes the value of hardware on the nc or lc
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

askeyHwRefValue 1.3.6.1.4.1.3646.1300.2.15.1.1.5
This object describes the reference value of hardware on the nc or lc
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

askeyHwValueThreshholdLow 1.3.6.1.4.1.3646.1300.2.15.1.1.6
This object describes the low-bound value of the voltage on the nc or lc. If the measured value is lower than the value, the system will report the alarm.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

askeyHwValueThreshholdHigh 1.3.6.1.4.1.3646.1300.2.15.1.1.7
This object describes the high-bound value of the voltage on the nc or lc. If the measured value is higher than the value, the system will report the alarm.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

sensorThresholds 1.3.6.1.4.1.3646.1300.2.15.2
OBJECT IDENTIFIER    

sensorTempHigh 1.3.6.1.4.1.3646.1300.2.15.2.1
The threshold for temperature up bound. Its range is from -20 C to 100 C
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER -20..100  

sensorTempLow 1.3.6.1.4.1.3646.1300.2.15.2.2
The threshold for temperature low bound. Its range is from -20 C to 100 C
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER -20..100  

gbicModuleTable 1.3.6.1.4.1.3646.1300.2.15.3
GBIC module information
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    GbicModuleTableEntry

gbicModuleTableEntry 1.3.6.1.4.1.3646.1300.2.15.3.1
Tok_String
Status: current Access: not-accessible
OBJECT-TYPE    
  GbicModuleTableEntry  

gbicIdentifier 1.3.6.1.4.1.3646.1300.2.15.3.1.1
This object describes the identifier value specifies the physical device described by the serial information. A value 3 means SFP.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

gbicConnector 1.3.6.1.4.1.3646.1300.2.15.3.1.2
The connector value indicates the external connector provided on the interface. A value 1 means SC. A value 7 means LC.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

gbicTransceiver 1.3.6.1.4.1.3646.1300.2.15.3.1.3
This object describes the gigabit ethernet compliance codes.The following bit significant indicators define the electronic or optical interfaces that are supported by the GBIC. 6 - IEEE ethernet standard: bit 0 - 1000BASE-SX 1 - 1000BASE-LX 2 - 1000BASE-CX 3 - 1000BASE-Tn 7 - bit 0 - electrical inter-enclosure(EL) 1 - longwave laser(LC) distance capability: bit 4 - long distance(L) 5 - intermediate distance(I) 6 - short distance(S) 7 - very long distance(V) 8 - SONET compliance codes: bit 4 - longwave laser(LL) 5 - shortwave laser w/OFC(SL) 6 - shortwave laser w/o OFC(SN) 7 - intra-enclosure (EL) 9 - transmission media type: bit 0 - single mode(SM) 2 - multi-mode-50m(M5) 3 - multi-mode-62.5m(M6) 4 - video coax(TV) 5 - miniature coax(MI) 6 - shielded twisted pair(TP) 7 - twin axial pair(TW) 10 - fibre channel link length: bit 0 - 100MBytes/Sec 2 - 200MBytes/Sec 4 - 400MBytes/Sec
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

gbicEncoding 1.3.6.1.4.1.3646.1300.2.15.3.1.4
The encoding value indicates the serial encoding mechanism that is the nominal design target of the particular GBIC. value 0 - Unspecified 1 - 8B10B 2 - 4B5B 3 - NRZ 4 - Manchester 5 - SONET Scrambled
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

gbicBrNominal 1.3.6.1.4.1.3646.1300.2.15.3.1.5
The nominal bit rate (BR, nominal) is specified in units of 100 Megabits per second, rounded off to the nearest 100 Megabits per second. The bit rate includes those bits necessary to encode and delimit the signal as well as those bits carrying data information. A value of 0 indicates that the bit rate is not specified and must be determined from the transceiver technology. The actual information transfer rate will depend on the encoding of the data, as defined by the encoding value.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

gbicLength9um 1.3.6.1.4.1.3646.1300.2.15.3.1.6
This value specifies the link length that is supported by the GBIC while operating in compliance with the applicable standards using single mode fiber.The value is in units of 100 meters. A value of 255 means that the GBIC supports a link length greater than 25.4 km. A value of zero means that the GBIC does not support single mode fiber or that the length information must be determined from the transceiver technology.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

gbicLength50um 1.3.6.1.4.1.3646.1300.2.15.3.1.7
This value specifies the link length that is supported by the GBIC while operating in compliance with the applicable standards using 50 micron multi-mode fiber. The value is in units of 10 meters. A value of 255 means that the GBIC supports a link length greater than 2.54 km. A value of zero means that the GBIC does not support 50 micron multi-mode fiber or that the length information must be determined from the transceiver technology.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

gbicLength62-5um 1.3.6.1.4.1.3646.1300.2.15.3.1.8
This value specifies the link length that is supported by the GBIC while operating in compliance with the applicable standards using 62.5 micron multi-mode fiber. The value is in units of 10 meters. A value of 255 means that the GBIC supports a link length greater than 2.54 km. A value of zero means that the GBIC does not 62.5 micron multi-mode fiber or that the length information must determined from the transceiver technology. It is common for GBICs to support both 50 micron and 62.5 micron fiber.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

gbicCopperLength 1.3.6.1.4.1.3646.1300.2.15.3.1.9
This value specifies the minimum link length that is supported by the GBIC while operating in compliance with the applicable standards using copper cable. The value is in units of 1 meter. A value of 255 means that the GBIC supports a link length greater than 254 meters. A value of zero means that the GBIC does not support copper cables or that the length information must be determined from the transceiver technology. Further information about the cable design, equalization, and connectors is usually required to guarantee meeting a particular length requirement.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

gbicVendorName 1.3.6.1.4.1.3646.1300.2.15.3.1.10
The vendor name is a 16 character field that contains ASCII characters, left-aligned and padded on the right with ASCII spaces (20h). The vendor name shall be the full name of the corporation, a commonly accepted abbreviation of the name of the corporation, the SCSI company code for the corporation, or the stock exchange code for the corporation. At least one of the vendor name or the vendor OUI fields shall contain valid serial data.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

gbicVendorOUI 1.3.6.1.4.1.3646.1300.2.15.3.1.11
The vendor organizationally unique identifier field (vendor OUI) is a 3-byte field that contains the IEEE Company Identifier for the vendor. A value of all zero in the 3-byte field indicates that the Vendor OUI is unspecified.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

gbicVendorPN 1.3.6.1.4.1.3646.1300.2.15.3.1.12
The vendor part number (vendor PN) is a 16-byte field that contains ASCII characters, left-aligned and padded on the right with ASCII spaces (20h), defining the vendor part number or product name. A value of all zero in the 16-byte field indicates that the vendor PN is unspecified.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

gbicVendorSN 1.3.6.1.4.1.3646.1300.2.15.3.1.13
The vendor serial number (vendor SN) is a 16 character field that contains ASCII characters, left-aligned and padded on the right with ASCII spaces (20h), defining the vendor's serial number for the GBIC. A value of all zero in the 16-byte field indicates that the vendor PN is unspecified.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

gbicLaserWaveLength 1.3.6.1.4.1.3646.1300.2.15.3.1.14
This object describes the fibre channel transmitter wave laser length(nm).
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER