ASCEND-MIBSTATICHSSLOT-MIB

File: ASCEND-MIBSTATICHSSLOT-MIB.mib (8190 bytes)

Imported modules

ASCEND-MIB RFC1155-SMI RFC-1212

Imported symbols

configuration IpAddress OBJECT-TYPE

Defined Types

DisplayString  
OCTET STRING    

MibmibProfHighSpeedSlotStaticEntry  
SEQUENCE    
  mibProfHighSpeedSlotStatic-Shelf-o INTEGER
  mibProfHighSpeedSlotStatic-Slot-o INTEGER
  mibProfHighSpeedSlotStatic-Item-o INTEGER
  mibProfHighSpeedSlotStatic-Name DisplayString
  mibProfHighSpeedSlotStatic-PhysicalAddress-Shelf INTEGER
  mibProfHighSpeedSlotStatic-PhysicalAddress-Slot INTEGER
  mibProfHighSpeedSlotStatic-PhysicalAddress-ItemNumber INTEGER
  mibProfHighSpeedSlotStatic-AtmParameters-IncomingPriority INTEGER
  mibProfHighSpeedSlotStatic-TrunkCacConfig-Enable INTEGER
  mibProfHighSpeedSlotStatic-TrunkCacConfig-PortNum DisplayString
  mibProfHighSpeedSlotStatic-TrunkCacConfig-LineRate INTEGER
  mibProfHighSpeedSlotStatic-TrunkCacConfig-OverSubscription INTEGER
  mibProfHighSpeedSlotStatic-Action-o INTEGER

Defined Values

mibmibProfHighSpeedSlotStatic 1.3.6.1.4.1.529.23.32
OBJECT IDENTIFIER    

mibmibProfHighSpeedSlotStaticTable 1.3.6.1.4.1.529.23.32.1
A list of mibmibProfHighSpeedSlotStatic profile entries.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MibmibProfHighSpeedSlotStaticEntry

mibmibProfHighSpeedSlotStaticEntry 1.3.6.1.4.1.529.23.32.1.1
A mibmibProfHighSpeedSlotStatic entry containing objects that maps to the parameters of mibmibProfHighSpeedSlotStatic profile.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  MibmibProfHighSpeedSlotStaticEntry  

mibProfHighSpeedSlotStatic-Shelf-o 1.3.6.1.4.1.529.23.32.1.1.1
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

mibProfHighSpeedSlotStatic-Slot-o 1.3.6.1.4.1.529.23.32.1.1.2
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

mibProfHighSpeedSlotStatic-Item-o 1.3.6.1.4.1.529.23.32.1.1.3
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

mibProfHighSpeedSlotStatic-Name 1.3.6.1.4.1.529.23.32.1.1.4
For future use. The current design does not use this name attribute but instead references a LIM or CM slot by its profile index; we may in the future support referencing a LIM or CM slot by its name as well as by its physical address. This name attribute consists of a null-terminated ASCII string; is read-only; and defaults to the ASCII form of this LIM or CM slot physical address.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString  

mibProfHighSpeedSlotStatic-PhysicalAddress-Shelf 1.3.6.1.4.1.529.23.32.1.1.5
The number of the shelf that the addressed physical device resides on.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER anyShelf(1), shelf1(2), shelf2(3), shelf3(4), shelf4(5), shelf5(6), shelf6(7), shelf7(8), shelf8(9), shelf9(10)  

mibProfHighSpeedSlotStatic-PhysicalAddress-Slot 1.3.6.1.4.1.529.23.32.1.1.6
The number of the slot that the addressed physical device resides on.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER anySlot(1), slot1(2), slot2(3), slot3(4), slot4(5), slot5(6), slot6(7), slot7(8), slot8(9), slot9(10), slot10(11), slot11(12), slot12(13), slot13(14), slot14(15), slot15(16), slot16(17), slot17(18), slot18(19), slot19(20), slot20(21), slot21(22), slot22(23), slot23(24), slot24(25), slot25(26), slot26(27), slot27(28), slot28(29), slot29(30), slot30(31), slot31(32), slot32(33), slot33(34), slot34(35), slot35(36), slot36(37), slot37(38), slot38(39), slot39(40), slot40(41), aLim(55), bLim(56), cLim(57), dLim(58), leftController(49), rightController(50), controller(42), firstControlModule(53), secondControlModule(54), trunkModule1(45), trunkModule2(46), controlModule(51), slotPrimary(59)  

mibProfHighSpeedSlotStatic-PhysicalAddress-ItemNumber 1.3.6.1.4.1.529.23.32.1.1.7
A number that specifies an addressable entity within the context of shelf and slot.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

mibProfHighSpeedSlotStatic-AtmParameters-IncomingPriority 1.3.6.1.4.1.529.23.32.1.1.8
Specifies the relative priority of ATM cells incoming from this LIM or CM slot. A slot's incoming-priority is used to select the appropriate outgoing queue that is associated with the outgoing port from the internal ATM cell processing engine. All ports on this slot and all ATM service categories share the same incoming-priority. An outgoing port (from the internal ATM cell processing engine) can have multiple queues associated with a given QoS. The incoming-priority is used to select which queue to use among all the queues associated with the given QoS.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER lowPriority(1), highPriority(2)  

mibProfHighSpeedSlotStatic-TrunkCacConfig-Enable 1.3.6.1.4.1.529.23.32.1.1.10
Enable or Disable CAC on this port. yes: CAC is enable on this port. no: CAC is disable on this port
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

mibProfHighSpeedSlotStatic-TrunkCacConfig-PortNum 1.3.6.1.4.1.529.23.32.1.1.11
Identifies this trunk port within the system. It is a read only field.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

mibProfHighSpeedSlotStatic-TrunkCacConfig-LineRate 1.3.6.1.4.1.529.23.32.1.1.12
Line rate of the trunk port in Kbits/sec. The trunk port can have real-time (guaranteed) traffic bandwidth up to this limit. In case of over subscription, there is no guarantee.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

mibProfHighSpeedSlotStatic-TrunkCacConfig-OverSubscription 1.3.6.1.4.1.529.23.32.1.1.13
Allowed to specify over subscription to the line rate to a factor of over-subscription/10. e.g Allowed BW = (over-subscription * line-rate) /10
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

mibProfHighSpeedSlotStatic-Action-o 1.3.6.1.4.1.529.23.32.1.1.9
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER noAction(1), createProfile(2), deleteProfile(3)