ASCEND-MIBSDSLNET-MIB

File: ASCEND-MIBSDSLNET-MIB.mib (14289 bytes)

Imported modules

ASCEND-MIB RFC1155-SMI RFC-1212

Imported symbols

configuration IpAddress OBJECT-TYPE

Defined Types

DisplayString  
OCTET STRING    

MibsdslNetworkProfileEntry  
SEQUENCE    
  sdslNetworkProfile-Shelf-o INTEGER
  sdslNetworkProfile-Slot-o INTEGER
  sdslNetworkProfile-Item-o INTEGER
  sdslNetworkProfile-Name DisplayString
  sdslNetworkProfile-PhysicalAddress-Shelf INTEGER
  sdslNetworkProfile-PhysicalAddress-Slot INTEGER
  sdslNetworkProfile-PhysicalAddress-ItemNumber INTEGER
  sdslNetworkProfile-Enabled INTEGER
  sdslNetworkProfile-SparingMode INTEGER
  sdslNetworkProfile-ProfileNumber INTEGER
  sdslNetworkProfile-IgnoreLineup INTEGER
  sdslNetworkProfile-LineConfig-TrunkGroup INTEGER
  sdslNetworkProfile-LineConfig-NailedGroup INTEGER
  sdslNetworkProfile-LineConfig-VpSwitchingVpi INTEGER
  sdslNetworkProfile-LineConfig-RoutePort-SlotNumber-SlotNumber INTEGER
  sdslNetworkProfile-LineConfig-RoutePort-SlotNumber-ShelfNumber INTEGER
  sdslNetworkProfile-LineConfig-RoutePort-RelativePortNumber-RelativePortNumber INTEGER
  sdslNetworkProfile-LineConfig-Activation INTEGER
  sdslNetworkProfile-LineConfig-DataSense INTEGER
  sdslNetworkProfile-LineConfig-SdslDataFormat INTEGER
  sdslNetworkProfile-LineConfig-DataRateMode INTEGER
  sdslNetworkProfile-LineConfig-MaxRate INTEGER
  sdslNetworkProfile-LineConfig-AutoBaseRate INTEGER
  sdslNetworkProfile-LineConfig-UnitType INTEGER
  sdslNetworkProfile-LineConfig-Enabled INTEGER
  sdslNetworkProfile-LineConfig-LineMode INTEGER
  sdslNetworkProfile-LineConfig-LoopBack INTEGER
  sdslNetworkProfile-DhcpConfig-IpAddress IpAddress
  sdslNetworkProfile-DhcpConfig-MaxLease INTEGER
  sdslNetworkProfile-Action-o INTEGER

Defined Values

mibsdslNetworkProfile 1.3.6.1.4.1.529.23.8
OBJECT IDENTIFIER    

mibsdslNetworkProfileTable 1.3.6.1.4.1.529.23.8.1
A list of mibsdslNetworkProfile profile entries.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MibsdslNetworkProfileEntry

mibsdslNetworkProfileEntry 1.3.6.1.4.1.529.23.8.1.1
A mibsdslNetworkProfile entry containing objects that maps to the parameters of mibsdslNetworkProfile profile.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  MibsdslNetworkProfileEntry  

sdslNetworkProfile-Shelf-o 1.3.6.1.4.1.529.23.8.1.1.1
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sdslNetworkProfile-Slot-o 1.3.6.1.4.1.529.23.8.1.1.2
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sdslNetworkProfile-Item-o 1.3.6.1.4.1.529.23.8.1.1.3
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sdslNetworkProfile-Name 1.3.6.1.4.1.529.23.8.1.1.4
For future use. The current design does not use the name field but instead references Sdsl lines by the physical address; we may in the future support referencing Sdsl lines by name as well as by address. The name consists of a null terminated ascii string supplied by the user; it defaults to the ascii form of the Sdsl line physical address.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString  

sdslNetworkProfile-PhysicalAddress-Shelf 1.3.6.1.4.1.529.23.8.1.1.5
The number of the shelf that the addressed physical device resides on.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER anyShelf(1), shelf1(2), shelf2(3), shelf3(4), shelf4(5), shelf5(6), shelf6(7), shelf7(8), shelf8(9), shelf9(10)  

sdslNetworkProfile-PhysicalAddress-Slot 1.3.6.1.4.1.529.23.8.1.1.6
The number of the slot that the addressed physical device resides on.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER anySlot(1), slot1(2), slot2(3), slot3(4), slot4(5), slot5(6), slot6(7), slot7(8), slot8(9), slot9(10), slot10(11), slot11(12), slot12(13), slot13(14), slot14(15), slot15(16), slot16(17), slot17(18), slot18(19), slot19(20), slot20(21), slot21(22), slot22(23), slot23(24), slot24(25), slot25(26), slot26(27), slot27(28), slot28(29), slot29(30), slot30(31), slot31(32), slot32(33), slot33(34), slot34(35), slot35(36), slot36(37), slot37(38), slot38(39), slot39(40), slot40(41), aLim(55), bLim(56), cLim(57), dLim(58), leftController(49), rightController(50), controller(42), firstControlModule(53), secondControlModule(54), trunkModule1(45), trunkModule2(46), controlModule(51), slotPrimary(59)  

sdslNetworkProfile-PhysicalAddress-ItemNumber 1.3.6.1.4.1.529.23.8.1.1.7
A number that specifies an addressable entity within the context of shelf and slot.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

sdslNetworkProfile-Enabled 1.3.6.1.4.1.529.23.8.1.1.8
TRUE if the line is enabled, otherwise FALSE.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

sdslNetworkProfile-SparingMode 1.3.6.1.4.1.529.23.8.1.1.31
Port sparing operational mode for this port.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER inactive(1), manual(2), automatic(3)  

sdslNetworkProfile-ProfileNumber 1.3.6.1.4.1.529.23.8.1.1.9
For potential backwards compatibility. The current design consists of one line profile numbered 0.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

sdslNetworkProfile-IgnoreLineup 1.3.6.1.4.1.529.23.8.1.1.34
Ignore line up value for this port.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER systemDefined(1), no(2), yes(3)  

sdslNetworkProfile-LineConfig-TrunkGroup 1.3.6.1.4.1.529.23.8.1.1.10
The trunk group to which this line is assigned. 0 means this line is not part of a trunk group.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

sdslNetworkProfile-LineConfig-NailedGroup 1.3.6.1.4.1.529.23.8.1.1.11
A number that identifies the set of lines that makes up a nailed group. 0 means this line is not part of a nailed group.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

sdslNetworkProfile-LineConfig-VpSwitchingVpi 1.3.6.1.4.1.529.23.8.1.1.27
The Vpi to be used for the VP switching. Rest of the valid VPIs in valid vpi-vci-range will be used for the VC switching. Changes in this range will take effect immediately. THE USER SHOULD BE VERY CAREFUL WHILE CHANGING THIS VALUE BECAUSE ALL CONNECTIONS ON THE LIM WHERE THIS PORT BELONGS WILL BE DROPPED IN ORDER TO MAKE THIS NEW VALUE EFFECTIVE IMMEDIATELY.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

sdslNetworkProfile-LineConfig-RoutePort-SlotNumber-SlotNumber 1.3.6.1.4.1.529.23.8.1.1.12
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

sdslNetworkProfile-LineConfig-RoutePort-SlotNumber-ShelfNumber 1.3.6.1.4.1.529.23.8.1.1.13
TNT is a multi shelf system. To minimise the changes required to existing code the shelf number is added to this structure as it will almost always be needed when a slot number is needed.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

sdslNetworkProfile-LineConfig-RoutePort-RelativePortNumber-RelativePortNumber 1.3.6.1.4.1.529.23.8.1.1.14
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

sdslNetworkProfile-LineConfig-Activation 1.3.6.1.4.1.529.23.8.1.1.15
Line activation mode.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER static(1), dsrActive(2), dcdDsrActive(3)  

sdslNetworkProfile-LineConfig-DataSense 1.3.6.1.4.1.529.23.8.1.1.26
If this value is set to Inverted, the Tx data will be inverted and the Rx data will be expected to be inverted. Otherwise the Tx and Rx data will be non-inverted.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER normal(1), inv(2)  

sdslNetworkProfile-LineConfig-SdslDataFormat 1.3.6.1.4.1.529.23.8.1.1.30
If this value is set to Mag bit 1st, the sdsl-data-format outputs the magnitude before the sign bit. Otherwise with value set to sign bit 1st, the sdsl-data-format outputs the sign before the magnitude bit. This is our default.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER serial(1)  

sdslNetworkProfile-LineConfig-DataRateMode 1.3.6.1.4.1.529.23.8.1.1.19
The data rate mode defines the mode for modem training. This parameter does not pertain to the old 16 port sdsl card.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER autobaud(2), singlebaud(3), fastautobaud(4)  

sdslNetworkProfile-LineConfig-MaxRate 1.3.6.1.4.1.529.23.8.1.1.20
The symetrical interface rate. This parameter does not pertain to the old 16 port sdsl card.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER n-144000(1), n-272000(2), n-400000(3), n-528000(4), n-784000(5), n-1168000(6), n-1552000(7), n-2320000(8), n-160000(9), n-192000(10), n-208000(11), n-384000(12), n-416000(13), n-768000(14), n-1040000(15), n-1152000(16), n-1536000(17), n-1568000(18), n-1680000(19), n-1920000(20), n-2160000(21)  

sdslNetworkProfile-LineConfig-AutoBaseRate 1.3.6.1.4.1.529.23.8.1.1.25
When the Rate Mode is set to auto. This parameter defines the base rate that the auto rate mechanism uses to start its initial training with.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER n-144000(1), n-272000(2), n-400000(3), n-528000(4), n-784000(5), n-1168000(6), n-1552000(7), n-2320000(8), n-160000(9), n-192000(10), n-208000(11), n-384000(12), n-416000(13), n-768000(14), n-1040000(15), n-1152000(16), n-1536000(17), n-1568000(18), n-1680000(19), n-1920000(20), n-2160000(21)  

sdslNetworkProfile-LineConfig-UnitType 1.3.6.1.4.1.529.23.8.1.1.21
The Unit Type defines if a line is acting as either a Central Office (COE) or Customer Premise Equipment (CPE). Note that the remote unit needs to be configured opposite to this configureation. This parameter does not pertain to the old 16 port sdsl card.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER coe(1), cpe(2)  

sdslNetworkProfile-LineConfig-Enabled 1.3.6.1.4.1.529.23.8.1.1.24
TRUE if the line is enabled, otherwise FALSE.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

sdslNetworkProfile-LineConfig-LineMode 1.3.6.1.4.1.529.23.8.1.1.32
This line can be configured to run in ATM or HDLC serial mode.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER atm(1), hdlc(2)  

sdslNetworkProfile-LineConfig-LoopBack 1.3.6.1.4.1.529.23.8.1.1.33
Configuration of different modem loopbacks.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER none(1), analog(2), digital(3)  

sdslNetworkProfile-DhcpConfig-IpAddress 1.3.6.1.4.1.529.23.8.1.1.28
The static address to be assigned to dhcp client.
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

sdslNetworkProfile-DhcpConfig-MaxLease 1.3.6.1.4.1.529.23.8.1.1.29
A number representing maximum number lease requests that would be granted.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

sdslNetworkProfile-Action-o 1.3.6.1.4.1.529.23.8.1.1.22
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER noAction(1), createProfile(2), deleteProfile(3)