ASCEND-MIBHDSL2NET-MIB

File: ASCEND-MIBHDSL2NET-MIB.mib (24188 bytes)

Imported modules

ASCEND-MIB RFC1155-SMI RFC-1212

Imported symbols

configuration IpAddress OBJECT-TYPE

Defined Types

DisplayString  
OCTET STRING    

Mibhdsl2NetworkProfileEntry  
SEQUENCE    
  hdsl2NetworkProfile-Shelf-o INTEGER
  hdsl2NetworkProfile-Slot-o INTEGER
  hdsl2NetworkProfile-Item-o INTEGER
  hdsl2NetworkProfile-Name DisplayString
  hdsl2NetworkProfile-PhysicalAddress-Shelf INTEGER
  hdsl2NetworkProfile-PhysicalAddress-Slot INTEGER
  hdsl2NetworkProfile-PhysicalAddress-ItemNumber INTEGER
  hdsl2NetworkProfile-Enabled INTEGER
  hdsl2NetworkProfile-SparingMode INTEGER
  hdsl2NetworkProfile-IgnoreLineup INTEGER
  hdsl2NetworkProfile-ProfileNumber INTEGER
  hdsl2NetworkProfile-LineConfig-TrunkGroup INTEGER
  hdsl2NetworkProfile-LineConfig-NailedGroup INTEGER
  hdsl2NetworkProfile-LineConfig-VpSwitchingVpi INTEGER
  hdsl2NetworkProfile-LineConfig-RoutePort-SlotNumber-SlotNumber INTEGER
  hdsl2NetworkProfile-LineConfig-RoutePort-SlotNumber-ShelfNumber INTEGER
  hdsl2NetworkProfile-LineConfig-RoutePort-RelativePortNumber-RelativePortNumber INTEGER
  hdsl2NetworkProfile-LineConfig-Activation INTEGER
  hdsl2NetworkProfile-LineConfig-CallRouteInfo-Shelf INTEGER
  hdsl2NetworkProfile-LineConfig-CallRouteInfo-Slot INTEGER
  hdsl2NetworkProfile-LineConfig-CallRouteInfo-ItemNumber INTEGER
  hdsl2NetworkProfile-LineConfig-UnitType INTEGER
  hdsl2NetworkProfile-LineConfig-NtrEnabled INTEGER
  hdsl2NetworkProfile-LineConfig-ClockSource INTEGER
  hdsl2NetworkProfile-LineConfig-ClockPriority INTEGER
  hdsl2NetworkProfile-LineConfig-LoopBack INTEGER
  hdsl2NetworkProfile-LineConfig-Margin INTEGER
  hdsl2NetworkProfile-LineConfig-SnextMargin INTEGER
  hdsl2NetworkProfile-LineConfig-RateMode INTEGER
  hdsl2NetworkProfile-LineConfig-MinRate INTEGER
  hdsl2NetworkProfile-LineConfig-MaxRate INTEGER
  hdsl2NetworkProfile-LineConfig-GshdslStandardNetworkType INTEGER
  hdsl2NetworkProfile-LineConfig-AnnexbAnfpEnabled INTEGER
  hdsl2NetworkProfile-LineConfig-GshdslPsdType INTEGER
  hdsl2NetworkProfile-ThreshProfiles-SpanThreshProfile DisplayString
  hdsl2NetworkProfile-ThreshProfiles-XtucThreshProfile DisplayString
  hdsl2NetworkProfile-ThreshProfiles-XturThreshProfile DisplayString
  hdsl2NetworkProfile-Action-o INTEGER

Mibhdsl2NetworkProfile-ThreshProfiles-UnitThreshProfilesEntry  
SEQUENCE    
  hdsl2NetworkProfile-ThreshProfiles-UnitThreshProfiles-Shelf-o INTEGER
  hdsl2NetworkProfile-ThreshProfiles-UnitThreshProfiles-Slot-o INTEGER
  hdsl2NetworkProfile-ThreshProfiles-UnitThreshProfiles-Item-o INTEGER
  hdsl2NetworkProfile-ThreshProfiles-UnitThreshProfiles-Index-o INTEGER
  hdsl2NetworkProfile-ThreshProfiles-UnitThreshProfiles-XruNetThreshProfile DisplayString
  hdsl2NetworkProfile-ThreshProfiles-UnitThreshProfiles-XruCustThreshProfile DisplayString

Defined Values

mibhdsl2NetworkProfile 1.3.6.1.4.1.529.23.14
OBJECT IDENTIFIER    

mibhdsl2NetworkProfileTable 1.3.6.1.4.1.529.23.14.1
A list of mibhdsl2NetworkProfile profile entries.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Mibhdsl2NetworkProfileEntry

mibhdsl2NetworkProfileEntry 1.3.6.1.4.1.529.23.14.1.1
A mibhdsl2NetworkProfile entry containing objects that maps to the parameters of mibhdsl2NetworkProfile profile.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Mibhdsl2NetworkProfileEntry  

hdsl2NetworkProfile-Shelf-o 1.3.6.1.4.1.529.23.14.1.1.1
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

hdsl2NetworkProfile-Slot-o 1.3.6.1.4.1.529.23.14.1.1.2
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

hdsl2NetworkProfile-Item-o 1.3.6.1.4.1.529.23.14.1.1.3
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

hdsl2NetworkProfile-Name 1.3.6.1.4.1.529.23.14.1.1.4
For future use. The current design does not use the name field but instead references Hdsl2 lines by the physical address; we may in the future support referencing Hdsl2 lines by name as well as by address. The name consists of a null terminated ascii string supplied by the user; it defaults to the ascii form of the Hdsl2 line physical address.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString  

hdsl2NetworkProfile-PhysicalAddress-Shelf 1.3.6.1.4.1.529.23.14.1.1.5
The number of the shelf that the addressed physical device resides on.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER anyShelf(1), shelf1(2), shelf2(3), shelf3(4), shelf4(5), shelf5(6), shelf6(7), shelf7(8), shelf8(9), shelf9(10)  

hdsl2NetworkProfile-PhysicalAddress-Slot 1.3.6.1.4.1.529.23.14.1.1.6
The number of the slot that the addressed physical device resides on.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER anySlot(1), slot1(2), slot2(3), slot3(4), slot4(5), slot5(6), slot6(7), slot7(8), slot8(9), slot9(10), slot10(11), slot11(12), slot12(13), slot13(14), slot14(15), slot15(16), slot16(17), slot17(18), slot18(19), slot19(20), slot20(21), slot21(22), slot22(23), slot23(24), slot24(25), slot25(26), slot26(27), slot27(28), slot28(29), slot29(30), slot30(31), slot31(32), slot32(33), slot33(34), slot34(35), slot35(36), slot36(37), slot37(38), slot38(39), slot39(40), slot40(41), aLim(55), bLim(56), cLim(57), dLim(58), leftController(49), rightController(50), controller(42), firstControlModule(53), secondControlModule(54), trunkModule1(45), trunkModule2(46), controlModule(51), slotPrimary(59)  

hdsl2NetworkProfile-PhysicalAddress-ItemNumber 1.3.6.1.4.1.529.23.14.1.1.7
A number that specifies an addressable entity within the context of shelf and slot.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

hdsl2NetworkProfile-Enabled 1.3.6.1.4.1.529.23.14.1.1.8
TRUE if the line is enabled, otherwise FALSE.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

hdsl2NetworkProfile-SparingMode 1.3.6.1.4.1.529.23.14.1.1.24
Port sparing operational mode for this port.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER inactive(1), manual(2), automatic(3)  

hdsl2NetworkProfile-IgnoreLineup 1.3.6.1.4.1.529.23.14.1.1.29
Ignore line up value for this port.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER systemDefined(1), no(2), yes(3)  

hdsl2NetworkProfile-ProfileNumber 1.3.6.1.4.1.529.23.14.1.1.9
For potential backwards compatibility. The current design consists of one line profile numbered 0.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

hdsl2NetworkProfile-LineConfig-TrunkGroup 1.3.6.1.4.1.529.23.14.1.1.10
The trunk group to which this line is assigned. 0 means this line is not part of a trunk group.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

hdsl2NetworkProfile-LineConfig-NailedGroup 1.3.6.1.4.1.529.23.14.1.1.11
A number that identifies the set of lines that makes up a nailed group. 0 means this line is not part of a nailed group.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

hdsl2NetworkProfile-LineConfig-VpSwitchingVpi 1.3.6.1.4.1.529.23.14.1.1.12
The Vpi to be used for the VP switching. Rest of the valid VPIs in valid vpi-vci-range will be used for the VC switching. Changes in this range will take effect immediately. THE USER SHOULD BE VERY CAREFUL WHILE CHANGING THIS VALUE BECAUSE ALL CONNECTIONS ON THE LIM WHERE THIS PORT BELONGS WILL BE DROPPED IN ORDER TO MAKE THIS NEW VALUE EFFECTIVE IMMEDIATELY.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

hdsl2NetworkProfile-LineConfig-RoutePort-SlotNumber-SlotNumber 1.3.6.1.4.1.529.23.14.1.1.13
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

hdsl2NetworkProfile-LineConfig-RoutePort-SlotNumber-ShelfNumber 1.3.6.1.4.1.529.23.14.1.1.14
TNT is a multi shelf system. To minimise the changes required to existing code the shelf number is added to this structure as it will almost always be needed when a slot number is needed.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

hdsl2NetworkProfile-LineConfig-RoutePort-RelativePortNumber-RelativePortNumber 1.3.6.1.4.1.529.23.14.1.1.15
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

hdsl2NetworkProfile-LineConfig-Activation 1.3.6.1.4.1.529.23.14.1.1.16
Line activation mode.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER static(1), dsrActive(2), dcdDsrActive(3)  

hdsl2NetworkProfile-LineConfig-CallRouteInfo-Shelf 1.3.6.1.4.1.529.23.14.1.1.17
The number of the shelf that the addressed physical device resides on.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER anyShelf(1), shelf1(2), shelf2(3), shelf3(4), shelf4(5), shelf5(6), shelf6(7), shelf7(8), shelf8(9), shelf9(10)  

hdsl2NetworkProfile-LineConfig-CallRouteInfo-Slot 1.3.6.1.4.1.529.23.14.1.1.18
The number of the slot that the addressed physical device resides on.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER anySlot(1), slot1(2), slot2(3), slot3(4), slot4(5), slot5(6), slot6(7), slot7(8), slot8(9), slot9(10), slot10(11), slot11(12), slot12(13), slot13(14), slot14(15), slot15(16), slot16(17), slot17(18), slot18(19), slot19(20), slot20(21), slot21(22), slot22(23), slot23(24), slot24(25), slot25(26), slot26(27), slot27(28), slot28(29), slot29(30), slot30(31), slot31(32), slot32(33), slot33(34), slot34(35), slot35(36), slot36(37), slot37(38), slot38(39), slot39(40), slot40(41), aLim(55), bLim(56), cLim(57), dLim(58), leftController(49), rightController(50), controller(42), firstControlModule(53), secondControlModule(54), trunkModule1(45), trunkModule2(46), controlModule(51), slotPrimary(59)  

hdsl2NetworkProfile-LineConfig-CallRouteInfo-ItemNumber 1.3.6.1.4.1.529.23.14.1.1.19
A number that specifies an addressable entity within the context of shelf and slot.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

hdsl2NetworkProfile-LineConfig-UnitType 1.3.6.1.4.1.529.23.14.1.1.20
The Unit Type defines if a line is acting as either a Central Office (COE) or Customer Premise Equipment (CPE). Note that the remote unit needs to be configured opposite to this configureation.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER coe(1), cpe(2)  

hdsl2NetworkProfile-LineConfig-NtrEnabled 1.3.6.1.4.1.529.23.14.1.1.25
TRUE if NTR functionality is enabled, otherwise FALSE. If the unit-type is COE, it will take the system clock as the input when NTR is enabled and allow the remote CPE port to recover the clock. If the unit-type is CPE, it will allow the port to possibly output the recovered clock as the system clock (if elected, see clock-source and clock-priority fields) when NTR is enabled.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

hdsl2NetworkProfile-LineConfig-ClockSource 1.3.6.1.4.1.529.23.14.1.1.26
Determine whether the 8KHz clock from the HDSL2 line (unit-type has to be CPE and ntr-enabled has to be yes) is eligible to be used as the 8KHz system clock source.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER eligible(1), notEligible(2)  

hdsl2NetworkProfile-LineConfig-ClockPriority 1.3.6.1.4.1.529.23.14.1.1.27
Clock priority assigned to the HDSL2 line. Used to select a particular HDSL2 line as the 8KHz system clock source.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER highPriority(2), middlePriority(3), lowPriority(4)  

hdsl2NetworkProfile-LineConfig-LoopBack 1.3.6.1.4.1.529.23.14.1.1.28
Configuration of different modem loopbacks.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER none(1), analog(2), digital(3)  

hdsl2NetworkProfile-LineConfig-Margin 1.3.6.1.4.1.529.23.14.1.1.30
Selects a margin range between the signal to noise floor.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER n-0db(1), n-1db(2), n-2db(3), n-3db(4), n-4db(5), n-5db(6), n-6db(7), n-7db(8), n-8db(9), n-9db(10), n-10db(11), disable(17)  

hdsl2NetworkProfile-LineConfig-SnextMargin 1.3.6.1.4.1.529.23.14.1.1.39
Selects a Snext margin range with a worst-case self next noise model given current loop insertion loss.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER n-0db(1), n-1db(2), n-2db(3), n-3db(4), n-4db(5), n-5db(6), n-6db(7), n-7db(8), n-8db(9), n-9db(10), n-10db(11), n-plus-10db(12), n-plus-9db(13), n-plus-8db(14), n-plus-7db(15), n-plus-6db(16), n-plus-5db(17), n-plus-4db(18), n-plus-3db(19), n-plus-2db(20), n-plus-1db(21), disable(22)  

hdsl2NetworkProfile-LineConfig-RateMode 1.3.6.1.4.1.529.23.14.1.1.31
Used for G.SHDSL technology. Selects if the modem operates in Fixed or Auto rate mode.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER fixed(1), auto(2)  

hdsl2NetworkProfile-LineConfig-MinRate 1.3.6.1.4.1.529.23.14.1.1.32
Used for G.SHDSL technology. When the rate-mode is set to Auto, this is the minimum rate the modem will train to.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER n-72000(72001), n-136000(136001), n-200000(200001), n-264000(264001), n-328000(328001), n-392000(392001), n-520000(520001), n-776000(776001), n-1032000(1032001), n-1160000(1160001), n-1288000(1288001), n-1544000(1544001), n-2056000(2056001), n-2312000(2312001)  

hdsl2NetworkProfile-LineConfig-MaxRate 1.3.6.1.4.1.529.23.14.1.1.33
Used for G.SHDSL technology. When the rate-mode is set to Auto, this is the maximum rate the modem will train to. When the rate-mode is set to Fixed, this is the only rate the mode trains to.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER n-72000(72001), n-136000(136001), n-200000(200001), n-264000(264001), n-328000(328001), n-392000(392001), n-520000(520001), n-776000(776001), n-1032000(1032001), n-1160000(1160001), n-1288000(1288001), n-1544000(1544001), n-2056000(2056001), n-2312000(2312001)  

hdsl2NetworkProfile-LineConfig-GshdslStandardNetworkType 1.3.6.1.4.1.529.23.14.1.1.34
Per the G.SHDSL Standard G.991.2. This parameter allows selection for the modem to operate either the North American Annex 'A' or European Annex 'B' standard network types. The setting of auto-detect is only valid for CPE to train off of COE Standard Network settings.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER northAmericanAnnexA(1), europeanAnnexB(2), autoDetect(3)  

hdsl2NetworkProfile-LineConfig-AnnexbAnfpEnabled 1.3.6.1.4.1.529.23.14.1.1.40
TRUE if Annex B ANFP functionality is enabled, otherwise FALSE. The gshdsl-standard-network-type must be set to European Annex B, and the port cannot be CPE. This field makes the modem perform in Annex B mode, but slightly differently. This is to comply with the UK ANFP requirements and pass the BTexact Technologies PSD measurement technique to meet BT approval. Only enable this field for that test specifically.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

hdsl2NetworkProfile-LineConfig-GshdslPsdType 1.3.6.1.4.1.529.23.14.1.1.35
Per the G.SHDSL Standard G.911.2. This parameter allows selection for the modem to output a symmetric PSD at all rates or asymmetric PSD's at fixed rates of 776kbps, 784kbps, 1544kbps, or 1552kbps for Annex A networks. Annex B networks support fixed rates of 2056kbps or 2304kbps. The setting of auto-detect is only valid for CPE to train off of COE PSD settings.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER symmetric(1), asymmetric776kPsdAnnexA(4), asymmetric1544kPsdAnnexA(5), asymmetric2056kPsdAnnexB(6), asymmetric2312kPsdAnnexB(7), autoDetect(8)  

hdsl2NetworkProfile-ThreshProfiles-SpanThreshProfile 1.3.6.1.4.1.529.23.14.1.1.36
The name consists of a null terminated ascii string supplied by the user. This profile defines the thresholds for all the HDSL2/SHDSL units for this port unless otherwise specified by the individual parameters in this subprofile.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString  

hdsl2NetworkProfile-ThreshProfiles-XtucThreshProfile 1.3.6.1.4.1.529.23.14.1.1.37
The name consists of a null terminated ascii string supplied by the user. This profile defines the thresholds for the DSLAM.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString  

hdsl2NetworkProfile-ThreshProfiles-XturThreshProfile 1.3.6.1.4.1.529.23.14.1.1.38
The name consists of a null terminated ascii string supplied by the user. This profile defines the thresholds for the remote CPE.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString  

hdsl2NetworkProfile-Action-o 1.3.6.1.4.1.529.23.14.1.1.23
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER noAction(1), createProfile(2), deleteProfile(3)  

mibhdsl2NetworkProfile-ThreshProfiles-UnitThreshProfilesTable 1.3.6.1.4.1.529.23.14.2
A list of mibhdsl2NetworkProfile__thresh_profiles__unit_thresh_profiles profile entries.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Mibhdsl2NetworkProfile-ThreshProfiles-UnitThreshProfilesEntry

mibhdsl2NetworkProfile-ThreshProfiles-UnitThreshProfilesEntry 1.3.6.1.4.1.529.23.14.2.1
A mibhdsl2NetworkProfile__thresh_profiles__unit_thresh_profiles entry containing objects that maps to the parameters of mibhdsl2NetworkProfile__thresh_profiles__unit_thresh_profiles profile.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Mibhdsl2NetworkProfile-ThreshProfiles-UnitThreshProfilesEntry  

hdsl2NetworkProfile-ThreshProfiles-UnitThreshProfiles-Shelf-o 1.3.6.1.4.1.529.23.14.2.1.1
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

hdsl2NetworkProfile-ThreshProfiles-UnitThreshProfiles-Slot-o 1.3.6.1.4.1.529.23.14.2.1.2
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

hdsl2NetworkProfile-ThreshProfiles-UnitThreshProfiles-Item-o 1.3.6.1.4.1.529.23.14.2.1.3
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

hdsl2NetworkProfile-ThreshProfiles-UnitThreshProfiles-Index-o 1.3.6.1.4.1.529.23.14.2.1.4
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

hdsl2NetworkProfile-ThreshProfiles-UnitThreshProfiles-XruNetThreshProfile 1.3.6.1.4.1.529.23.14.2.1.5
The name consists of a null terminated ascii string supplied by the user. This profile defines the thresholds for the network side of regenerator unit 1.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString  

hdsl2NetworkProfile-ThreshProfiles-UnitThreshProfiles-XruCustThreshProfile 1.3.6.1.4.1.529.23.14.2.1.6
The name consists of a null terminated ascii string supplied by the user. This profile defines the thresholds for the customer side of regenerator unit 1.
Status: mandatory Access: read-write
OBJECT-TYPE    