ASCEND-MIBCLTMACCESS-MIB

File: ASCEND-MIBCLTMACCESS-MIB.mib (4652 bytes)

Imported modules

ASCEND-MIB RFC1155-SMI RFC-1212

Imported symbols

configuration IpAddress OBJECT-TYPE

Defined Types

DisplayString  
OCTET STRING    

MibcltmAccessEntry  
SEQUENCE    
  cltmAccess-Index-o INTEGER
  cltmAccess-CltmSlot INTEGER
  cltmAccess-AccessSlot INTEGER
  cltmAccess-AccessPort INTEGER
  cltmAccess-AccessLoop INTEGER
  cltmAccess-AccessMode INTEGER
  cltmAccess-AccessTerminal INTEGER
  cltmAccess-ActivateAccess INTEGER
  cltmAccess-AccessResult INTEGER
  cltmAccess-Action-o INTEGER

Defined Values

mibcltmAccess 1.3.6.1.4.1.529.23.67
OBJECT IDENTIFIER    

mibcltmAccessTable 1.3.6.1.4.1.529.23.67.1
A list of mibcltmAccess profile entries.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MibcltmAccessEntry

mibcltmAccessEntry 1.3.6.1.4.1.529.23.67.1.1
A mibcltmAccess entry containing objects that maps to the parameters of mibcltmAccess profile.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  MibcltmAccessEntry  

cltmAccess-Index-o 1.3.6.1.4.1.529.23.67.1.1.1
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cltmAccess-CltmSlot 1.3.6.1.4.1.529.23.67.1.1.2
Identify the CLTM slot within the system.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER anySlot(1), slot1(2), slot2(3), slot3(4), slot4(5), slot5(6), slot6(7), slot7(8), slot10(11), slot11(12), slot12(13), slot13(14), slot14(15), slot15(16), slot16(17)  

cltmAccess-AccessSlot 1.3.6.1.4.1.529.23.67.1.1.3
Identify the slot of the copper loop to be accessed.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER anySlot(1), slot1(2), slot2(3), slot3(4), slot4(5), slot5(6), slot6(7), slot7(8), slot10(11), slot11(12), slot12(13), slot13(14), slot14(15), slot15(16), slot16(17)  

cltmAccess-AccessPort 1.3.6.1.4.1.529.23.67.1.1.4
Identify the port of the copper loop to be accessed.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

cltmAccess-AccessLoop 1.3.6.1.4.1.529.23.67.1.1.10
Identify the the copper loop to be accessed.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

cltmAccess-AccessMode 1.3.6.1.4.1.529.23.67.1.1.5
The mode of the CLTM access.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER lookingOut(1), bridged(2)  

cltmAccess-AccessTerminal 1.3.6.1.4.1.529.23.67.1.1.6
The tester terminal to access the test copper loop.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER internalTesterTerminal(1), externalTesterTerminal(2), auxiliaryTesterTerminal(3), externalLoop(4)  

cltmAccess-ActivateAccess 1.3.6.1.4.1.529.23.67.1.1.7
Activate/Deactivate access.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

cltmAccess-AccessResult 1.3.6.1.4.1.529.23.67.1.1.8
The result of activating the copper loop access.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER idle(1), accessActivated(2), resourceBusy(3)  

cltmAccess-Action-o 1.3.6.1.4.1.529.23.67.1.1.9
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER noAction(1), createProfile(2), deleteProfile(3)