ASCEND-MIBAPSCFG-MIB

File: ASCEND-MIBAPSCFG-MIB.mib (9153 bytes)

Imported modules

ASCEND-MIB RFC1155-SMI RFC-1212

Imported symbols

configuration IpAddress OBJECT-TYPE

Defined Types

DisplayString  
OCTET STRING    

MibapsConfigEntry  
SEQUENCE    
  apsConfig-Name DisplayString
  apsConfig-Active INTEGER
  apsConfig-LinearProtectionChannel-Shelf INTEGER
  apsConfig-LinearProtectionChannel-Slot INTEGER
  apsConfig-LinearProtectionChannel-ItemNumber INTEGER
  apsConfig-ProtectionMode INTEGER
  apsConfig-DirectionMode INTEGER
  apsConfig-RevertiveMode INTEGER
  apsConfig-WtrTimerDuration INTEGER
  apsConfig-PsbfFailureTimerDuration INTEGER
  apsConfig-PsbfClearTimerDuration INTEGER
  apsConfig-ModeMismatchFailureTimerDuration INTEGER
  apsConfig-ModeMismatchClearTimerDuration INTEGER
  apsConfig-ChannelMismatchFailureTimerDuration INTEGER
  apsConfig-ChannelMismatchClearTimerDuration INTEGER
  apsConfig-FeplMismatchFailureTimerDuration INTEGER
  apsConfig-FeplMismatchClearTimerDuration INTEGER
  apsConfig-ProtectionChannelSignalDegradeExponent INTEGER
  apsConfig-ProtectionChannelSignalFailureExponent INTEGER
  apsConfig-WorkingChannelSignalDegradeExponent INTEGER
  apsConfig-WorkingChannelSignalFailureExponent INTEGER
  apsConfig-Action-o INTEGER

Defined Values

mibapsConfig 1.3.6.1.4.1.529.23.148
OBJECT IDENTIFIER    

mibapsConfigTable 1.3.6.1.4.1.529.23.148.1
A list of mibapsConfig profile entries.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MibapsConfigEntry

mibapsConfigEntry 1.3.6.1.4.1.529.23.148.1.1
A mibapsConfig entry containing objects that maps to the parameters of mibapsConfig profile.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  MibapsConfigEntry  

apsConfig-Name 1.3.6.1.4.1.529.23.148.1.1.1
Name of APS Config profile.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

apsConfig-Active 1.3.6.1.4.1.529.23.148.1.1.2
TRUE if the working line is to join a protection group, FALSE otherwise.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

apsConfig-LinearProtectionChannel-Shelf 1.3.6.1.4.1.529.23.148.1.1.3
The number of the shelf that the addressed physical device resides on.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER anyShelf(1), shelf1(2), shelf2(3), shelf3(4), shelf4(5), shelf5(6), shelf6(7), shelf7(8), shelf8(9), shelf9(10)  

apsConfig-LinearProtectionChannel-Slot 1.3.6.1.4.1.529.23.148.1.1.4
The number of the slot that the addressed physical device resides on.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER anySlot(1), slot1(2), slot2(3), slot3(4), slot4(5), slot5(6), slot6(7), slot7(8), slot8(9), slot9(10), slot10(11), slot11(12), slot12(13), slot13(14), slot14(15), slot15(16), slot16(17), slot17(18), slot18(19), slot19(20), slot20(21), slot21(22), slot22(23), slot23(24), slot24(25), slot25(26), slot26(27), slot27(28), slot28(29), slot29(30), slot30(31), slot31(32), slot32(33), slot33(34), slot34(35), slot35(36), slot36(37), slot37(38), slot38(39), slot39(40), slot40(41), aLim(55), bLim(56), cLim(57), dLim(58), leftController(49), rightController(50), controller(42), firstControlModule(53), secondControlModule(54), trunkModule1(45), trunkModule2(46), controlModule(51), slotPrimary(59)  

apsConfig-LinearProtectionChannel-ItemNumber 1.3.6.1.4.1.529.23.148.1.1.5
A number that specifies an addressable entity within the context of shelf and slot.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

apsConfig-ProtectionMode 1.3.6.1.4.1.529.23.148.1.1.6
The linear APS protection mode (1+1, 1:n).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER n-1-plus-1(1), n-1-divide-n(2)  

apsConfig-DirectionMode 1.3.6.1.4.1.529.23.148.1.1.7
specifies the protection group direction mode
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER unidirectional(1), bidirectional(2)  

apsConfig-RevertiveMode 1.3.6.1.4.1.529.23.148.1.1.8
specifies the protection group revertive mode
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER nonRevertive(2), revertive(1)  

apsConfig-WtrTimerDuration 1.3.6.1.4.1.529.23.148.1.1.9
specifies the protection group's waiting time to revert timer duration (in tens of milliseconds)
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

apsConfig-PsbfFailureTimerDuration 1.3.6.1.4.1.529.23.148.1.1.10
specifies the PSBF failure timer duration (in tens of milliseconds)
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

apsConfig-PsbfClearTimerDuration 1.3.6.1.4.1.529.23.148.1.1.11
specifies the PSBF clear timer duration (in tens of milliseconds)
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

apsConfig-ModeMismatchFailureTimerDuration 1.3.6.1.4.1.529.23.148.1.1.12
Specifies the Mode Mismatch failure timer duration (in tens of milliseconds)
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

apsConfig-ModeMismatchClearTimerDuration 1.3.6.1.4.1.529.23.148.1.1.13
Specifies the Mode Mismatch clear timer duration (in tens of milliseconds)
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

apsConfig-ChannelMismatchFailureTimerDuration 1.3.6.1.4.1.529.23.148.1.1.14
Specifies the Channel Mismatch Failure Timer duration (in tens of milliseconds)
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

apsConfig-ChannelMismatchClearTimerDuration 1.3.6.1.4.1.529.23.148.1.1.15
Specifies the Channel Mismatch Clear Timer duration (in tens of milliseconds)
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

apsConfig-FeplMismatchFailureTimerDuration 1.3.6.1.4.1.529.23.148.1.1.16
Specifies the FEPL Failure Mismatch timer duration (in tens of milliseconds)
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

apsConfig-FeplMismatchClearTimerDuration 1.3.6.1.4.1.529.23.148.1.1.17
Specifies the FEPL Clear Mismatch timer duration (in tens of milliseconds)
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

apsConfig-ProtectionChannelSignalDegradeExponent 1.3.6.1.4.1.529.23.148.1.1.18
Specifies the signal degrade exponent for the protection channel
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

apsConfig-ProtectionChannelSignalFailureExponent 1.3.6.1.4.1.529.23.148.1.1.19
Specifies the signal failure exponent for the protection channel
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

apsConfig-WorkingChannelSignalDegradeExponent 1.3.6.1.4.1.529.23.148.1.1.20
Specifies the signal degrade exponent for the working channel
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

apsConfig-WorkingChannelSignalFailureExponent 1.3.6.1.4.1.529.23.148.1.1.21
Specifies the signal failure exponent for the working channel
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

apsConfig-Action-o 1.3.6.1.4.1.529.23.148.1.1.22
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER noAction(1), createProfile(2), deleteProfile(3)