ASCEND-ADSL-CAP-MIB

File: ASCEND-ADSL-CAP-MIB.mib (12683 bytes)

Imported modules

ASCEND-WAN-MIB RFC-1212

Imported symbols

wanTypeAdslCap OBJECT-TYPE

Defined Types

AdslCapLineStatusEntry  
SEQUENCE    
  adslCapStatusIfEntryIndex INTEGER
  adslCapStatusShelfIndex INTEGER
  adslCapStatusSlotIndex INTEGER
  adslCapStatusLineIndex INTEGER
  adslCapStatusUnitType INTEGER
  adslCapStatusLineState INTEGER
  adslCapStatusUpRate INTEGER
  adslCapStatusDownRate INTEGER
  adslCapStatusVendorId INTEGER
  adslCapStatusMajorFirmWareVer INTEGER
  adslCapStatusMinorFirmWareVer INTEGER
  adslCapStatusHardWareVer INTEGER

AdslCapLineStatisticEntry  
SEQUENCE    
  adslCapStatIfEntryIndex INTEGER
  adslCapStatShelfIndex INTEGER
  adslCapStatSlotIndex INTEGER
  adslCapStatLineIndex INTEGER
  adslCapStatConnUpDays INTEGER
  adslCapStatConnUpHours INTEGER
  adslCapStatConnUpMinutes INTEGER
  adslCapStatRxSignalPresent INTEGER
  adslCapStatLineQualityDb INTEGER
  adslCapStatUpDwnCntr INTEGER
  adslCapStatLineSelfTest INTEGER
  adslCapStatBertTimer INTEGER
  adslCapStatBertEna INTEGER
  adslCapStatBertState INTEGER
  adslCapStatBertErrorCounter INTEGER

Defined Values

adslCapLineStatusTable 1.3.6.1.4.1.529.4.9.1
ADSL CAP status parameters.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AdslCapLineStatusEntry

adslCapLineStatusEntry 1.3.6.1.4.1.529.4.9.1.1
A interface status entry containing objects to describe the interface.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  AdslCapLineStatusEntry  

adslCapStatusIfEntryIndex 1.3.6.1.4.1.529.4.9.1.1.1
Index into the Status Table via the interface group ifIndex value.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..7fffffff  

adslCapStatusShelfIndex 1.3.6.1.4.1.529.4.9.1.1.2
TNT's ADSL CAP modules Shelf ID.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

adslCapStatusSlotIndex 1.3.6.1.4.1.529.4.9.1.1.3
TNT's ADSL CAP modules Slot ID.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

adslCapStatusLineIndex 1.3.6.1.4.1.529.4.9.1.1.4
ADSL CAP modules line ID.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

adslCapStatusUnitType 1.3.6.1.4.1.529.4.9.1.1.5
Unit type defines if the unit is operating either as a Central Office Equipment (COE) or Customer Premiss equipment (CPE).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(1), coe(2), cpe(3)  

adslCapStatusLineState 1.3.6.1.4.1.529.4.9.1.1.6
Interface state describes the current ports operating state. States are: Config, Pend Down, Up, Down, Start-up, or N/A.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(1), configure(2), deactivate(3), deactive-lost(4), start-up(5), pend-port-up(6), up(7), pend-deactivate(8), out-of-service(9), analog-loopback(10), digital-loopback(11)  

adslCapStatusUpRate 1.3.6.1.4.1.529.4.9.1.1.7
When parameter is read, it displays the current up stream (cpe to coe) rate which can differ from the written value.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER m1088000(1088000), k952000(952000), k816000(816000), k680000(680000), k544000(544000), k408000(408000), k272000(272000)  

adslCapStatusDownRate 1.3.6.1.4.1.529.4.9.1.1.8
When parameter is read, it displays the current down stream (coe to cpe) rate which can differ from the written value.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER m7168000(7168000), m6272000(6272000), m5120000(5120000), m4480000(4480000), m3200000(3200000), m2688000(2688000), m2560000(2560000), m2240000(2240000), m1920000(1920000), m1600000(1600000), m1280000(1280000), k960000(960000), k640000(640000)  

adslCapStatusVendorId 1.3.6.1.4.1.529.4.9.1.1.9
Vendor identification.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

adslCapStatusMajorFirmWareVer 1.3.6.1.4.1.529.4.9.1.1.10
Major firmware version.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

adslCapStatusMinorFirmWareVer 1.3.6.1.4.1.529.4.9.1.1.11
Minor firmware version.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

adslCapStatusHardWareVer 1.3.6.1.4.1.529.4.9.1.1.12
Hardware version.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

adslCapLineStatisticTable 1.3.6.1.4.1.529.4.9.2
ADSL CAP statistical parameters.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AdslCapLineStatisticEntry

adslCapLineStatisticEntry 1.3.6.1.4.1.529.4.9.2.1
A interface statistical entry containing objects to describe the interface.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  AdslCapLineStatisticEntry  

adslCapStatIfEntryIndex 1.3.6.1.4.1.529.4.9.2.1.1
Index into the Status Table via the interface group ifIndex value.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..7fffffff  

adslCapStatShelfIndex 1.3.6.1.4.1.529.4.9.2.1.2
ADSL CAP modules Shelf ID.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

adslCapStatSlotIndex 1.3.6.1.4.1.529.4.9.2.1.3
ADSL CAP modules Slot ID.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

adslCapStatLineIndex 1.3.6.1.4.1.529.4.9.2.1.4
ADSL CAP modules interface ID.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

adslCapStatConnUpDays 1.3.6.1.4.1.529.4.9.2.1.5
Connection up day count.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

adslCapStatConnUpHours 1.3.6.1.4.1.529.4.9.2.1.6
Connection Up 24 hour count.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

adslCapStatConnUpMinutes 1.3.6.1.4.1.529.4.9.2.1.7
Connection up minute count.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

adslCapStatRxSignalPresent 1.3.6.1.4.1.529.4.9.2.1.8
Receive signal present detection.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

adslCapStatLineQualityDb 1.3.6.1.4.1.529.4.9.2.1.9
Lines noise margin. Reliable data will transfer with a reading of -5db or greater.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

adslCapStatUpDwnCntr 1.3.6.1.4.1.529.4.9.2.1.10
Line Up Down counter value displays the number of times the interface transitions from a down to up state.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

adslCapStatLineSelfTest 1.3.6.1.4.1.529.4.9.2.1.11
Line hardware self test results (Passed or Failed).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(4), selfTestFailed(1), localLoopBackFailed(2), passed(3)  

adslCapStatBertTimer 1.3.6.1.4.1.529.4.9.2.1.12
BER test duration configuration. When two nodes are physically connected, the BER test lasts for the duration of this timer.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER one-minute(1), two-minutes(2), three-minutes(3), four-minutes(4), five-minutes(5), ten-minutes(6), fifteen-minutes(7), twenty-minutes(8), thirty-minutes(9)  

adslCapStatBertEna 1.3.6.1.4.1.529.4.9.2.1.13
Enable/disable of the BER test. If nodes are connected, then the BER test is ran between the units. If this node is not connected to a remote node, then the interface is placed into analog loopback and the BER test is started.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

adslCapStatBertState 1.3.6.1.4.1.529.4.9.2.1.14
BER test states. When this node is not connected to anyother node, then the state enters local-loop-active. When two nodes are conneced then different states are transistioned through. If this is the first node to enable the BER test, the state will transistion from stopped to waiting-for-511-sync. Now this node is waiting for the remote node to enable its BER test. Once the remote node enables its BER test, then both nodes enter the active state. At this point the BER test starts collecting bit errors.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER waiting-for-511-sync(1), local-loop-active(2), active(3), stopped(4), loop-back-setup(5), start-up(6), data-overflow(7), ber-sync-loss(8)  

adslCapStatBertErrorCounter 1.3.6.1.4.1.529.4.9.2.1.15
BER test bit error counter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER