ARUBAWIRED-LLDP-MIB

File: ARUBAWIRED-LLDP-MIB.mib (44963 bytes)

Imported modules

SNMPv2-SMI SNMPv2-TC SNMPv2-CONF
ARUBAWIRED-NETWORKING-OID LLDP-MIB ENTITY-MIB

Imported symbols

MODULE-IDENTITY OBJECT-TYPE Integer32
TEXTUAL-CONVENTION TruthValue MODULE-COMPLIANCE
OBJECT-GROUP wndFeatures lldpLocPortNum
lldpRemTimeMark lldpRemLocalPortNum lldpRemIndex
entPhysicalIndex

Defined Types

ArubaWiredLldpXdot3LocPowerEntry  
SEQUENCE    
  arubaWiredLldpXdot3LocPowerPortClass INTEGER
  arubaWiredLldpXdot3LocPowerMDISupported TruthValue
  arubaWiredLldpXdot3LocPowerMDIEnabled TruthValue
  arubaWiredLldpXdot3LocPowerPairControlable TruthValue
  arubaWiredLldpXdot3LocPowerPairs INTEGER
  arubaWiredLldpXdot3LocPowerClass INTEGER
  arubaWiredLldpXdot3LocPowerType INTEGER
  arubaWiredLldpXdot3LocPowerSource INTEGER
  arubaWiredLldpXdot3LocPowerPriority INTEGER
  arubaWiredLldpXdot3LocPDRequestedPowerValue Integer32
  arubaWiredLldpXdot3LocPDRequestedPowerValueA Integer32
  arubaWiredLldpXdot3LocPDRequestedPowerValueB Integer32
  arubaWiredLldpXdot3LocPSEAllocatedPowerValue Integer32
  arubaWiredLldpXdot3LocPSEAllocatedPowerValueA Integer32
  arubaWiredLldpXdot3LocPSEAllocatedPowerValueB Integer32
  arubaWiredLldpXdot3LocPSEPoweringStatus INTEGER
  arubaWiredLldpXdot3LocPowerPairsExt INTEGER
  arubaWiredLldpXdot3LocPowerClassExtA INTEGER
  arubaWiredLldpXdot3LocPowerClassExtB INTEGER
  arubaWiredLldpXdot3LocPowerClassExt INTEGER
  arubaWiredLldpXdot3LocPowerTypeExt INTEGER
  arubaWiredLldpXdot3LocPDLoad INTEGER
  arubaWiredLldpXdot3LocPSEMaxAvailPower Integer32
  arubaWiredLldpXdot3LocPSEAutoclassSupport TruthValue
  arubaWiredLldpXdot3LocAutoclassCompleted TruthValue
  arubaWiredLldpLocPseTlvSentType INTEGER
  arubaWiredLldpLocPdTlvSentType INTEGER

ArubaWiredLldpXdot3RemPowerEntry  
SEQUENCE    
  arubaWiredLldpXdot3RemPowerPortClass INTEGER
  arubaWiredLldpXdot3RemPowerMDISupported TruthValue
  arubaWiredLldpXdot3RemPowerMDIEnabled TruthValue
  arubaWiredLldpXdot3RemPowerPairControlable TruthValue
  arubaWiredLldpXdot3RemPowerPairs INTEGER
  arubaWiredLldpXdot3RemPowerClass INTEGER
  arubaWiredLldpXdot3RemPowerType INTEGER
  arubaWiredLldpXdot3RemPowerSource INTEGER
  arubaWiredLldpXdot3RemPowerPriority INTEGER
  arubaWiredLldpXdot3RemPDRequestedPowerValue Integer32
  arubaWiredLldpXdot3RemPDRequestedPowerValueA Integer32
  arubaWiredLldpXdot3RemPDRequestedPowerValueB Integer32
  arubaWiredLldpXdot3RemPSEAllocatedPowerValue Integer32
  arubaWiredLldpXdot3RemPSEAllocatedPowerValueA Integer32
  arubaWiredLldpXdot3RemPSEAllocatedPowerValueB Integer32
  arubaWiredLldpXdot3RemPDPoweredStatus INTEGER
  arubaWiredLldpXdot3RemPowerClassExtA INTEGER
  arubaWiredLldpXdot3RemPowerClassExtB INTEGER
  arubaWiredLldpXdot3RemPowerClassExt INTEGER
  arubaWiredLldpXdot3RemPowerTypeExt INTEGER
  arubaWiredLldpXdot3RemPDLoad INTEGER
  arubaWiredLldpXdot3RemPD4PID TruthValue
  arubaWiredLldpXdot3RemPSEMaxAvailPower Integer32
  arubaWiredLldpXdot3RemAutoclassRequest TruthValue
  arubaWiredLldpXdot3RemPowerDownRequest INTEGER
  arubaWiredLldpXdot3RemPowerDownTime INTEGER

Defined Values

arubaWiredLldpMIB 1.3.6.1.4.1.47196.4.1.1.3.9
This MIB module describes management objects that manage LLDP information related to Power Source Equipment (PSE). This is the MIB module related to HPE Aruba LLDP
MODULE-IDENTITY    

arubaWiredLldpXdot3Objects 1.3.6.1.4.1.47196.4.1.1.3.9.1
OBJECT IDENTIFIER    

arubaWiredLldpXdot3LocalData 1.3.6.1.4.1.47196.4.1.1.3.9.1.1
OBJECT IDENTIFIER    

arubaWiredLldpXdot3RemoteData 1.3.6.1.4.1.47196.4.1.1.3.9.1.2
OBJECT IDENTIFIER    

arubaWiredLldpXdot3LocPowerTable 1.3.6.1.4.1.47196.4.1.1.3.9.1.1.1
This table contains one row per port of power ethernet information (as a part of the LLDP 802.3bt organizational extension) on the local system known to this agent.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ArubaWiredLldpXdot3LocPowerEntry

arubaWiredLldpXdot3LocPowerEntry 1.3.6.1.4.1.47196.4.1.1.3.9.1.1.1.1
Information about a particular port component.
Status: current Access: not-accessible
OBJECT-TYPE    
  ArubaWiredLldpXdot3LocPowerEntry  

arubaWiredLldpXdot3LocPowerPortClass 1.3.6.1.4.1.47196.4.1.1.3.9.1.1.1.1.1
The value that identifies the port Class of the given port associated with the local system.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER pClassPSE(1), pClassPD(2)  

arubaWiredLldpXdot3LocPowerMDISupported 1.3.6.1.4.1.47196.4.1.1.3.9.1.1.1.1.2
The truth value used to indicate whether the MDI power is supported on the given port associated with the local system.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

arubaWiredLldpXdot3LocPowerMDIEnabled 1.3.6.1.4.1.47196.4.1.1.3.9.1.1.1.1.3
The truth value used to indicate whether the MDI power is enabled on given port associated with the local system.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

arubaWiredLldpXdot3LocPowerPairControlable 1.3.6.1.4.1.47196.4.1.1.3.9.1.1.1.1.4
The truth value used to indicate the ability to control which PSE Pinout Alternative is used for PD detection and power.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

arubaWiredLldpXdot3LocPowerPairs 1.3.6.1.4.1.47196.4.1.1.3.9.1.1.1.1.5
The truth value that identifies the PSE Pinout Alternative in use for detecting and supplying power to the PD.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER pairSignal(1), pairSpare(2)  

arubaWiredLldpXdot3LocPowerClass 1.3.6.1.4.1.47196.4.1.1.3.9.1.1.1.1.6
The truth value that indicates the requested Class of the PD.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER class0(1), class1(2), class2(3), class3(4), class4(5)  

arubaWiredLldpXdot3LocPowerType 1.3.6.1.4.1.47196.4.1.1.3.9.1.1.1.1.7
This field reflects the actual local power type.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER type2PSE(1), type2PD(2), type1PSE(3), type1PD(4)  

arubaWiredLldpXdot3LocPowerSource 1.3.6.1.4.1.47196.4.1.1.3.9.1.1.1.1.8
This field reflects the requested local device power source. When the power type is PSE, this field shall be set to primary(2) when the PSE is sourcing its power through the PI from its primary supply; to backup(3) when the PSE is sourcing its power through the PI from a backup source; and to unknown(1) when this information is not available.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), primary(2), backup(3), reserved(4)  

arubaWiredLldpXdot3LocPowerPriority 1.3.6.1.4.1.47196.4.1.1.3.9.1.1.1.1.9
This field reflects the requested local device power priority. When the power type is PD, this field shall be set to the power priority configured for the device. If a PD is unable to determine its power priority or it has not been configured, then this field shall be set to unknown(1). When the power type is PSE, this field shall be set to unknown(1).
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER unknown(1), critical(2), high(3), low(4)  

arubaWiredLldpXdot3LocPDRequestedPowerValue 1.3.6.1.4.1.47196.4.1.1.3.9.1.1.1.1.10
It indicates the maximum input average power the PD is requesting in units of 0.1 W.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..999  

arubaWiredLldpXdot3LocPDRequestedPowerValueA 1.3.6.1.4.1.47196.4.1.1.3.9.1.1.1.1.11
It indicates the PD requested power value for the Mode A pairset in units of 0.1 W.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..499  

arubaWiredLldpXdot3LocPDRequestedPowerValueB 1.3.6.1.4.1.47196.4.1.1.3.9.1.1.1.1.12
It indicates the PD requested power value for the Mode B pairset in units of 0.1 W.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..499  

arubaWiredLldpXdot3LocPSEAllocatedPowerValue 1.3.6.1.4.1.47196.4.1.1.3.9.1.1.1.1.13
It indicates the maximum input average power the PSE expects the PD to draw in units of 0.1 W.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..999  

arubaWiredLldpXdot3LocPSEAllocatedPowerValueA 1.3.6.1.4.1.47196.4.1.1.3.9.1.1.1.1.14
It indicates the maximum input average power levels the PSE expects the dual-signature PD to draw, in units of 0.1 W, on Alternative A, when the PSE provides power over 4-pair.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..499  

arubaWiredLldpXdot3LocPSEAllocatedPowerValueB 1.3.6.1.4.1.47196.4.1.1.3.9.1.1.1.1.15
It indicates the maximum input average power levels the PSE expects the dual-signature PD to draw, in units of 0.1 W, on Alternative B, when the PSE provides power over 4-pair.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..499  

arubaWiredLldpXdot3LocPSEPoweringStatus 1.3.6.1.4.1.47196.4.1.1.3.9.1.1.1.1.16
This field reflects the existing powering configuration of the PSE and thus indicates that the PSE is using the 'PSE allocated power value' field or is using the 'PSE allocated power value Alternative A' field and 'PSE allocated power value Alternative B' field. For a PD the contents of this attribute are undefined.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER twoPair(1), fourPsinglesigPD(2), fourPdualsigPD(3)  

arubaWiredLldpXdot3LocPowerPairsExt 1.3.6.1.4.1.47196.4.1.1.3.9.1.1.1.1.17
This field indicates the supported PSE Pinout Alternative. For a PD the contents of this attribute are undefined
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER altA(1), altB(2), both(3)  

arubaWiredLldpXdot3LocPowerClassExtA 1.3.6.1.4.1.47196.4.1.1.3.9.1.1.1.1.18
For a dual-signature PD, it indicates the requested Class for Mode A during Physical Layer Classification. For a single-signature PD, a read-only value set to 'singlesig'. For a PSE connected to a dual-signature PD, a read-only value that indicates the currently assigned Class for Mode A. For a PSE connected to a single-signature PD, or a PSE that operates only in 2-pair mode, the value is set to 'singlesig'
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER singlesig(1), class1(2), class2(3), class3(4), class4(5), class5(6)  

arubaWiredLldpXdot3LocPowerClassExtB 1.3.6.1.4.1.47196.4.1.1.3.9.1.1.1.1.19
For a dual-signature PD, it indicates the requested Class for Mode B during Physical Layer Classification. For a single-signature PD, a read-only value set to 'singlesig'. For a PSE connected to a dual-signature PD, a read-only value that indicates the currently assigned Class for Mode B. For a PSE connected to a single-signature PD, or a PSE that operates only in 2-pair mode, the value is set to 'singlesig'
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER singlesig(1), class1(2), class2(3), class3(4), class4(5), class5(6)  

arubaWiredLldpXdot3LocPowerClassExt 1.3.6.1.4.1.47196.4.1.1.3.9.1.1.1.1.20
For a single-signature PD, it indicates the requested Class during Physical Layer Classification. For a dual-signature PD, the value is set to 'dualsig'. For a PSE connected to a single-signature PD or a PSE that operates only in 2-pair mode, a readonly value that indicates the currently assigned Class. For a PSE connected to a dualsignature PD, a read-only value set to 'dualsig'.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER dualsig(1), class1(2), class2(3), class3(4), class4(5), class5(6), class6(7), class7(8), class8(9)  

arubaWiredLldpXdot3LocPowerTypeExt 1.3.6.1.4.1.47196.4.1.1.3.9.1.1.1.1.21
This field indicates if the local system is a Type 3 or Type 4 PSE or PD, and in the case of a Type 3 or Type 4 PD, if it is a single-signature PD or a dual-signature PD
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER type3PSE(1), type4PSE(2), type3singlesigPD(3), type3dualsigPD(4), type4singlesigPD(5), type4dualsigPD(6)  

arubaWiredLldpXdot3LocPDLoad 1.3.6.1.4.1.47196.4.1.1.3.9.1.1.1.1.22
The truth value used to indicate whether the load of a dual- signature PD is electrically isolated. For a single-signature PD, or a PSE, the value of this attribute is FALSE.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

arubaWiredLldpXdot3LocPSEMaxAvailPower 1.3.6.1.4.1.47196.4.1.1.3.9.1.1.1.1.23
It indicates the local PSE maximum available power value in units of 0.1 W.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..999  

arubaWiredLldpXdot3LocPSEAutoclassSupport 1.3.6.1.4.1.47196.4.1.1.3.9.1.1.1.1.24
It indicates whether the local PSE system supports Autoclass
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

arubaWiredLldpXdot3LocAutoclassCompleted 1.3.6.1.4.1.47196.4.1.1.3.9.1.1.1.1.25
It indicates whether the local PSE system has completed the Autoclass measurement
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

arubaWiredLldpLocPseTlvSentType 1.3.6.1.4.1.47196.4.1.1.3.9.1.1.1.1.26
This field specifies the set of TLVs that are actually sent by the PSE
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER med(1), dot3(2), dot3-ext(3)  

arubaWiredLldpLocPdTlvSentType 1.3.6.1.4.1.47196.4.1.1.3.9.1.1.1.1.27
This field specifies the set of TLVs that are actually sent by the PD
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER med(1), dot3(2), dot3-ext(3), medanddot3(4), medanddot3-ext(5)  

arubaWiredLldpXdot3RemPowerTable 1.3.6.1.4.1.47196.4.1.1.3.9.1.2.1
This table contains one row per port of power ethernet information (as a part of the LLDP 802.3bt organizational extension) on the remote system known to this agent.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ArubaWiredLldpXdot3RemPowerEntry

arubaWiredLldpXdot3RemPowerEntry 1.3.6.1.4.1.47196.4.1.1.3.9.1.2.1.1
Information about a particular port component.
Status: current Access: not-accessible
OBJECT-TYPE    
  ArubaWiredLldpXdot3RemPowerEntry  

arubaWiredLldpXdot3RemPowerPortClass 1.3.6.1.4.1.47196.4.1.1.3.9.1.2.1.1.1
The value that identifies the port Class of the given port associated with the remote system.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER pClassPSE(1), pClassPD(2)  

arubaWiredLldpXdot3RemPowerMDISupported 1.3.6.1.4.1.47196.4.1.1.3.9.1.2.1.1.2
The truth value used to indicate whether the MDI power is supported on the given port associated with the remote system.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

arubaWiredLldpXdot3RemPowerMDIEnabled 1.3.6.1.4.1.47196.4.1.1.3.9.1.2.1.1.3
The truth value used to indicate whether the MDI power is enabled on given port associated with the remote system.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

arubaWiredLldpXdot3RemPowerPairControlable 1.3.6.1.4.1.47196.4.1.1.3.9.1.2.1.1.4
The truth value used to indicate the ability to control which PSE Pinout Alternative is used for PD detection and power.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

arubaWiredLldpXdot3RemPowerPairs 1.3.6.1.4.1.47196.4.1.1.3.9.1.2.1.1.5
The truth value that identifies the PSE Pinout Alternative in use for detecting and supplying power to the PD.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER pairSignal(1), pairSpare(2)  

arubaWiredLldpXdot3RemPowerClass 1.3.6.1.4.1.47196.4.1.1.3.9.1.2.1.1.6
The truth value that indicates the requested Class of the PD.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER class0(1), class1(2), class2(3), class3(4), class4(5)  

arubaWiredLldpXdot3RemPowerType 1.3.6.1.4.1.47196.4.1.1.3.9.1.2.1.1.7
This field reflects the actual remote power type.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER type2PSE(1), type2PD(2), type1PSE(3), type1PD(4)  

arubaWiredLldpXdot3RemPowerSource 1.3.6.1.4.1.47196.4.1.1.3.9.1.2.1.1.8
This field reflects the remote device (PD) requested power source. This field is encoded as pseAndLocal(4) when a PD being powered both locally and by a PSE, to local(3) when the PD being powered locally only, and to pse(2) when the PD is being powered by a PSE
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), pse(2), local(3), pseAndLocal(4)  

arubaWiredLldpXdot3RemPowerPriority 1.3.6.1.4.1.47196.4.1.1.3.9.1.2.1.1.9
This field reflects the requested remote device power priority. When the power type is PD, this field shall be set to the power priority configured for the device. If a PD is unable to determine its power priority or it has not been configured, then this field shall be set to unknown(1). When the power type is PSE, this field shall be set to unknown(1).
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER unknown(1), critical(2), high(3), low(4)  

arubaWiredLldpXdot3RemPDRequestedPowerValue 1.3.6.1.4.1.47196.4.1.1.3.9.1.2.1.1.10
It indicates the maximum input average power the PD is requesting in units of 0.1 W.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..999  

arubaWiredLldpXdot3RemPDRequestedPowerValueA 1.3.6.1.4.1.47196.4.1.1.3.9.1.2.1.1.11
It indicates the PD requested power value for the Mode A pairset in units of 0.1 W.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..499  

arubaWiredLldpXdot3RemPDRequestedPowerValueB 1.3.6.1.4.1.47196.4.1.1.3.9.1.2.1.1.12
It indicates the PD requested power value for the Mode B pairset in units of 0.1 W.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..499  

arubaWiredLldpXdot3RemPSEAllocatedPowerValue 1.3.6.1.4.1.47196.4.1.1.3.9.1.2.1.1.13
It indicates the PSE allocated power value received from the remote system. For a PSE, it is the PSE allocated power value that was echoed back by the remote PD, in units of 0.1 W.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..999  

arubaWiredLldpXdot3RemPSEAllocatedPowerValueA 1.3.6.1.4.1.47196.4.1.1.3.9.1.2.1.1.14
It indicates the PSE allocated power value for the Alternative A pairset received from the remote system. For a PSE, it is the PSE allocated power value for the Alternative A pairset that was echoed back by the remote PD, in units of 0.1 W.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..499  

arubaWiredLldpXdot3RemPSEAllocatedPowerValueB 1.3.6.1.4.1.47196.4.1.1.3.9.1.2.1.1.15
It indicates the PSE allocated power value for the Alternative B pairset received from the remote system. For a PSE, it is the PSE allocated power value for the Alternative A pairset that was echoed back by the remote PD, in units of 0.1 W.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..499  

arubaWiredLldpXdot3RemPDPoweredStatus 1.3.6.1.4.1.47196.4.1.1.3.9.1.2.1.1.16
This field indicates the existing powered configuration of the PD and thus indicate that the PD is using the 'PD requested power value' field or is using the 'PD requested power value Mode A' field and the 'PD requested power value Mode B' field. For a PSE the contents of this attribute are undefined.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER singlesigPD(1), twoPdualsigPD(2), fourPdualsigPD(3)  

arubaWiredLldpXdot3RemPowerClassExtA 1.3.6.1.4.1.47196.4.1.1.3.9.1.2.1.1.17
For a dual-signature PD, a read-only value that indicates the currently assigned Class for Mode A by the remote 4-pair PSE. For a single-signature PD, or a dual-signature PD connected to a 2-pair only PSE, a read-only value set to 'singlesig' by the remote PSE. For a PSE connected to a dualsignature PD, a read-only value that indicates the requested Class for Mode A during Physical Layer classification by the remote PD. For a PSE connected to a single-signature PD, a read-only value set to 'singlesig' by the remote PD
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER singlesig(1), class1(2), class2(3), class3(4), class4(5), class5(6)  

arubaWiredLldpXdot3RemPowerClassExtB 1.3.6.1.4.1.47196.4.1.1.3.9.1.2.1.1.18
For a dual-signature PD, a read-only value that indicates the currently assigned Class for Mode A by the remote 4-pair PSE. For a single-signature PD, or a dual-signature PD connected to a 2-pair only PSE, a read-only value set to 'singlesig' by the remote PSE. For a PSE connected to a dualsignature PD, a read-only value that indicates the requested Class for Mode B during Physical Layer classification by the remote PD. For a PSE connected to a single-signature PD, a read-only value set to 'singlesig' by the remote PD.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER singlesig(1), class1(2), class2(3), class3(4), class4(5), class5(6)  

arubaWiredLldpXdot3RemPowerClassExt 1.3.6.1.4.1.47196.4.1.1.3.9.1.2.1.1.19
For a single-signature PD or a dual-signature PD connected to a 2-pair only PSE, a read-only value that indicates the currently assigned Class by the remote PSE. For a dual- signature PD connected to a 4-pair capable PSE, a read-only value set to 'dualsig' by the remote PSE. For a PSE connected to a single-signature PD, a read-only value that indicates the requested Class during Physical Layer classification by the remote PD. For a PSE connected to a dual-signature PD, a readonly value set to 'dualsig' by the remote PD.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER dualsig(1), class1(2), class2(3), class3(4), class4(5), class5(6), class6(7), class7(8), class8(9)  

arubaWiredLldpXdot3RemPowerTypeExt 1.3.6.1.4.1.47196.4.1.1.3.9.1.2.1.1.20
This field indicates if the remote system is a Type 3 or Type 4 PSE or PD, and in the case of a Type 3 or Type 4 PD, if it is a single-signature PD or dual-signature PD
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER type3PSE(1), type4PSE(2), type3singlesigPD(3), type3dualsigPD(4), type4singlesigPD(5), type4dualsigPD(6)  

arubaWiredLldpXdot3RemPDLoad 1.3.6.1.4.1.47196.4.1.1.3.9.1.2.1.1.21
The truth value used to indicate whether the load of the remote dual-signature PD is electrically isolated. For a PD this attribute is set to FALSE
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

arubaWiredLldpXdot3RemPD4PID 1.3.6.1.4.1.47196.4.1.1.3.9.1.2.1.1.22
The truth value used to indicate whether the remote PD system supports powering of both PD Modes
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

arubaWiredLldpXdot3RemPSEMaxAvailPower 1.3.6.1.4.1.47196.4.1.1.3.9.1.2.1.1.23
It indicates the remote PSE maximum available power value in units of 0.1 W.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..999  

arubaWiredLldpXdot3RemAutoclassRequest 1.3.6.1.4.1.47196.4.1.1.3.9.1.2.1.1.24
It indicates whether the remote PD system is requesting an Autoclass measurement
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

arubaWiredLldpXdot3RemPowerDownRequest 1.3.6.1.4.1.47196.4.1.1.3.9.1.2.1.1.25
It indicates that the remote PD system is requesting a power down when the value is 0x1D
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

arubaWiredLldpXdot3RemPowerDownTime 1.3.6.1.4.1.47196.4.1.1.3.9.1.2.1.1.26
It indicates the number of seconds the remote PD requests to stay powered off. A value of zero indicates an indefinite amount of time.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

arubaWiredLldpConformance 1.3.6.1.4.1.47196.4.1.1.3.9.2
OBJECT IDENTIFIER    

arubaWiredLldpCompliances 1.3.6.1.4.1.47196.4.1.1.3.9.2.1
OBJECT IDENTIFIER    

arubaWiredLldpGroups 1.3.6.1.4.1.47196.4.1.1.3.9.2.2
OBJECT IDENTIFIER    

arubaWiredLldpXdot3Compliance 1.3.6.1.4.1.47196.4.1.1.3.9.2.1.1
The compliance statement for LLDP implementation.
Status: current Access: read-only
MODULE-COMPLIANCE    

arubaWiredLldpXdot3LocSysGroup 1.3.6.1.4.1.47196.4.1.1.3.9.2.2.1
The collection of objects which are used to represent LLDP 802.3 organizational extension for POEP Local Device Information. This group is mandatory for agents which implement the LLDP 802.3 organizational extension for POEP.
Status: current Access: read-only
OBJECT-GROUP    

arubaWiredLldpXdot3RemSysGroup 1.3.6.1.4.1.47196.4.1.1.3.9.2.2.2
The collection of objects which are used to represent LLDP 802.3 organizational extension for POEP Remote Device Information. This group is mandatory for agents which implement the LLDP 802.3 organizational extension for POEP.
Status: current Access: read-only
OBJECT-GROUP