ARRIS-C3-FPD-MIB

File: ARRIS-C3-FPD-MIB.mib (15065 bytes)

Imported modules

SNMPv2-SMI ARRIS-MIB SNMPv2-CONF

Imported symbols

enterprises MODULE-IDENTITY OBJECT-TYPE
Unsigned32 Integer32 cmtsC3
OBJECT-GROUP MODULE-COMPLIANCE

Defined Types

DcxFPDMsgEntry  
SEQUENCE    
  dcxFPDMsgIndex Unsigned32
  dcxFPDMsgString OCTET STRING

Defined Values

cmtsC3FPDMIB 1.3.6.1.4.1.4115.1.4.3.3
This MIB manages the Front Panel Display (FPD) software on the Arris CMTS C3
MODULE-IDENTITY    

dcxFPDObjects 1.3.6.1.4.1.4115.1.4.3.3.1
OBJECT IDENTIFIER    

dcxFPDMsgTable 1.3.6.1.4.1.4115.1.4.3.3.1.1
Table of Front Panel LCD Messages.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    DcxFPDMsgEntry

dcxFPDMsgEntry 1.3.6.1.4.1.4115.1.4.3.3.1.1.1
.
Status: current Access: not-accessible
OBJECT-TYPE    
  DcxFPDMsgEntry  

dcxFPDMsgIndex 1.3.6.1.4.1.4115.1.4.3.3.1.1.1.1
Index used to order the FPD Messages.
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32  

dcxFPDMsgString 1.3.6.1.4.1.4115.1.4.3.3.1.1.1.2
Specifies a string that can be displayed on the front panel.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(0..12)  

dcxFPDControlGroup 1.3.6.1.4.1.4115.1.4.3.3.1.2
OBJECT IDENTIFIER    

dcxFPDAttachedStatus 1.3.6.1.4.1.4115.1.4.3.3.1.2.1
Displays if the front panel display is attached to the Cmts or not.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER attached(1), detached(2)  

dcxFPDPowerStatus1 1.3.6.1.4.1.4115.1.4.3.3.1.2.2
Specifies if the primary power supply is working. This is the rightmost power supply. The following values are possible: on(1) and off(2)
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER on(1), off(2)  

dcxFPDPowerStatus2 1.3.6.1.4.1.4115.1.4.3.3.1.2.3
Specifies if the secondary power supply is working. This is the leftmost power supply(nearest the fan tray). The following values are possible: on(1) and off(2)
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER on(1), off(2)  

dcxFPDTemp1Status 1.3.6.1.4.1.4115.1.4.3.3.1.2.4
Specifies the temperature reading for the sensor on the CPU card closest to the CPU.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

dcxFPDTemp2Status 1.3.6.1.4.1.4115.1.4.3.3.1.2.5
Specifies the temperature reading for the sensor on the CPU card, on the right hand side.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

dcxFPDTemp3Status 1.3.6.1.4.1.4115.1.4.3.3.1.2.6
Specifies the temperature reading for the sensor on the Kanga card under the Roo cards between RX4 and RX5.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

dcxFPDTemp4Status 1.3.6.1.4.1.4115.1.4.3.3.1.2.7
Specifies the temperature reading for the sensor on the Kanga card under the Roo cards between RX2 and RX3.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

dcxFPDFan1Status 1.3.6.1.4.1.4115.1.4.3.3.1.2.8
Specifies the fan status for the fan nearest the front of the box. The following values are possible: Rotating(1) and BadRotating(2). BadRotating is set when the fan is operating outside of dcxFPDFanUpperLimit and dcxFPDFanLowerLimit.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER rotating(1), badRotating(2)  

dcxFPDFan2Status 1.3.6.1.4.1.4115.1.4.3.3.1.2.9
Specifies the fan status for the fan 2nd from the front. The following values are possible: Rotating(1) and BadRotating(2). BadRotating is set when the fan is operating outside of dcxFPDFanUpperLimit and dcxFPDFanLowerLimit.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER rotating(1), badRotating(2)  

dcxFPDFan3Status 1.3.6.1.4.1.4115.1.4.3.3.1.2.10
Specifies the fan status for the fan 3rd from the front. The following values are possible: Rotating(1) and BadRotating(2). BadRotating is set when the fan is operating outside of dcxFPDFanUpperLimit and dcxFPDFanLowerLimit.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER rotating(1), badRotating(2)  

dcxFPDFan4Status 1.3.6.1.4.1.4115.1.4.3.3.1.2.11
Specifies the fan status for the fan 4th from the front. The following values are possible: Rotating(1) and BadRotating(2). BadRotating is set when the fan is operating outside of dcxFPDFanUpperLimit and dcxFPDFanLowerLimit.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER rotating(1), badRotating(2)  

dcxFPDFan5Status 1.3.6.1.4.1.4115.1.4.3.3.1.2.12
Specifies the fan status for the fan 5th from the front. The following values are possible: Rotating(1) and BadRotating(2). BadRotating is set when the fan is operating outside of dcxFPDFanUpperLimit and dcxFPDFanLowerLimit.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER rotating(1), badRotating(2)  

dcxFPDFan6Status 1.3.6.1.4.1.4115.1.4.3.3.1.2.13
Specifies the fan status for the fan nearest the back of the box The following values are possible: Rotating(1) and BadRotating(2). BadRotating is set when the fan is operating outside of dcxFPDFanUpperLimit and dcxFPDFanLowerLimit.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER rotating(1), badRotating(2)  

dcxFPDFanUpperLimit 1.3.6.1.4.1.4115.1.4.3.3.1.2.14
Specifies the upper fan limit(Upper threshold of expected current draw)
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..255  

dcxFPDFanLowerLimit 1.3.6.1.4.1.4115.1.4.3.3.1.2.15
Specifies the lower fan limit(Lower threshold of expected current draw)
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..255  

dcxFPDLCDContrast 1.3.6.1.4.1.4115.1.4.3.3.1.2.16
Specifies the contrast level for the LCD
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..65535  

dcxFPDLedSetStatus 1.3.6.1.4.1.4115.1.4.3.3.1.2.17
Used to turn on or off a Led on the front panel
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..65535  

dcxFPDHwRevision 1.3.6.1.4.1.4115.1.4.3.3.1.2.18
Specifies the front panel h/w revision
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

dcxFPDSwRevision 1.3.6.1.4.1.4115.1.4.3.3.1.2.19
Specifies the front panel s/w revision
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

dcxFPDTrapGroup 1.3.6.1.4.1.4115.1.4.3.3.1.3
OBJECT IDENTIFIER    

dcxFPDAttached 1.3.6.1.4.1.4115.1.4.3.3.1.3.1
Front Panel Display has been attached.
Status: current Access: read-only
NOTIFICATION-TYPE    

dcxFPDDetached 1.3.6.1.4.1.4115.1.4.3.3.1.3.2
Front Panel Display has been detached.
Status: current Access: read-only
NOTIFICATION-TYPE    

dcxFPDFan1Fail 1.3.6.1.4.1.4115.1.4.3.3.1.3.3
Fan nearest the front of the box failed
Status: current Access: read-only
NOTIFICATION-TYPE    

dcxFPDFan1FailClr 1.3.6.1.4.1.4115.1.4.3.3.1.3.4
Fan nearest the front of the box is working
Status: current Access: read-only
NOTIFICATION-TYPE    

dcxFPDFan2Fail 1.3.6.1.4.1.4115.1.4.3.3.1.3.5
Fan 2nd from the front failed
Status: current Access: read-only
NOTIFICATION-TYPE    

dcxFPDFan2FailClr 1.3.6.1.4.1.4115.1.4.3.3.1.3.6
Fan 2nd from the front is working
Status: current Access: read-only
NOTIFICATION-TYPE    

dcxFPDFan3Fail 1.3.6.1.4.1.4115.1.4.3.3.1.3.7
Fan 3rd from the front failed
Status: current Access: read-only
NOTIFICATION-TYPE    

dcxFPDFan3FailClr 1.3.6.1.4.1.4115.1.4.3.3.1.3.8
Fan 3rd from the front is working
Status: current Access: read-only
NOTIFICATION-TYPE    

dcxFPDFan4Fail 1.3.6.1.4.1.4115.1.4.3.3.1.3.9
Fan 4th from the front failed
Status: current Access: read-only
NOTIFICATION-TYPE    

dcxFPDFan4FailClr 1.3.6.1.4.1.4115.1.4.3.3.1.3.10
Fan 4th from the front is working
Status: current Access: read-only
NOTIFICATION-TYPE    

dcxFPDFan5Fail 1.3.6.1.4.1.4115.1.4.3.3.1.3.11
Fan 5th from the front failed
Status: current Access: read-only
NOTIFICATION-TYPE    

dcxFPDFan5FailClr 1.3.6.1.4.1.4115.1.4.3.3.1.3.12
Fan 5th from the front is working
Status: current Access: read-only
NOTIFICATION-TYPE    

dcxFPDFan6Fail 1.3.6.1.4.1.4115.1.4.3.3.1.3.13
Fan nearest the back of the box failed
Status: current Access: read-only
NOTIFICATION-TYPE    

dcxFPDFan6FailClr 1.3.6.1.4.1.4115.1.4.3.3.1.3.14
Fan nearest the back of the box is working
Status: current Access: read-only
NOTIFICATION-TYPE    

dcxFPDPwr1Fail 1.3.6.1.4.1.4115.1.4.3.3.1.3.15
Rightmost power supply failed
Status: current Access: read-only
NOTIFICATION-TYPE    

dcxFPDPwr1FailClr 1.3.6.1.4.1.4115.1.4.3.3.1.3.16
Rightmost power supply is working
Status: current Access: read-only
NOTIFICATION-TYPE    

dcxFPDPwr2Fail 1.3.6.1.4.1.4115.1.4.3.3.1.3.17
Leftmost power supply failed
Status: current Access: read-only
NOTIFICATION-TYPE    

dcxFPDPwr2FailClr 1.3.6.1.4.1.4115.1.4.3.3.1.3.18
Leftmost power supply is working
Status: current Access: read-only
NOTIFICATION-TYPE    

dcxFPDTempOkay 1.3.6.1.4.1.4115.1.4.3.3.1.3.19
System temperature is OK
Status: current Access: read-only
NOTIFICATION-TYPE    

dcxFPDTempBad 1.3.6.1.4.1.4115.1.4.3.3.1.3.20
System temperature is too hot!
Status: current Access: read-only
NOTIFICATION-TYPE    

dcxFPDTempCritical 1.3.6.1.4.1.4115.1.4.3.3.1.3.21
System temperature is critical!!!, CMTS will shut itself down!!!!
Status: current Access: read-only
NOTIFICATION-TYPE    

dcxFPDConformance 1.3.6.1.4.1.4115.1.4.3.3.1.4
OBJECT IDENTIFIER    

dcxFPDCompliances 1.3.6.1.4.1.4115.1.4.3.3.1.4.1
OBJECT IDENTIFIER    

dcxFPDGroups 1.3.6.1.4.1.4115.1.4.3.3.1.4.2
OBJECT IDENTIFIER    

dcxFPDCompliance 1.3.6.1.4.1.4115.1.4.3.3.1.4.1.1
The compliance statement for devices that implement Arris C3 compliant FPD features
Status: current Access: read-only
MODULE-COMPLIANCE    

dcxFPDMsgGroup 1.3.6.1.4.1.4115.1.4.3.3.1.4.2.1
Arris C3 FPD message group
Status: current Access: read-only
OBJECT-GROUP    

dcxFPDControlConfGroup 1.3.6.1.4.1.4115.1.4.3.3.1.4.2.2
Arris C3 FPD Control group
Status: current Access: read-only
OBJECT-GROUP