ALCATEL-IND1-INLINE-POWER-MIB

File: ALCATEL-IND1-INLINE-POWER-MIB.mib (14189 bytes)

Imported modules

SNMPv2-SMI POWER-ETHERNET-MIB SNMPv2-CONF
ALCATEL-IND1-BASE

Imported symbols

MODULE-IDENTITY OBJECT-TYPE Integer32
NOTIFICATION-TYPE pethPsePortEntry pethMainPseEntry
MODULE-COMPLIANCE OBJECT-GROUP NOTIFICATION-GROUP
softentIND1InLinePower pethTraps

Defined Types

AlaPethPsePortEntry  
SEQUENCE    
  alaPethPsePortPowerMaximum INTEGER
  alaPethPsePortPowerActual INTEGER
  alaPethPsePortPowerStatus INTEGER
  alaPethPsePortPowerClass INTEGER

AlaPethMainPseEntry  
SEQUENCE    
  alaPethMainPseAdminStatus INTEGER
  alaPethMainPseMaxPower Integer32
  alaPethMainPsePriorityDisconnect INTEGER
  alaPethMainPseCapacitorDetect INTEGER
  alaPethMainPsePriority INTEGER
  alaPethMainPseComboPort INTEGER

AlaPethMainEntry  
SEQUENCE    
  alaPethMainIndex Integer32
  alaPethMainPowerRedundancy INTEGER

Defined Values

alcatelIND1INLINEPOWERMIB 1.3.6.1.4.1.6486.801.1.2.1.27.1
This module describes an authoritative enterprise-specific Simple Network Management Protocol (SNMP) Management Information Base (MIB): Propietary InLinePower Extensions MIB definitions The right to make changes in specification and other information contained in this document without prior notice is reserved. No liability shall be assumed for any incidental, indirect, special, or consequential damages whatsoever arising from or related to this document or the information contained herein. Vendors, end-users, and other interested parties are granted non-exclusive license to use this specification in connection with management of the products for which it is intended to be used. Copyright (C) 1995-2007 Alcatel-Lucent ALL RIGHTS RESERVED WORLDWIDE
MODULE-IDENTITY    

alaPethObjects 1.3.6.1.4.1.6486.801.1.2.1.27.1.1
OBJECT IDENTIFIER    

alaPethConformance 1.3.6.1.4.1.6486.801.1.2.1.27.1.2
OBJECT IDENTIFIER    

alaPethMain 1.3.6.1.4.1.6486.801.1.2.1.27.1.3
OBJECT IDENTIFIER    

alaPethPsePortTable 1.3.6.1.4.1.6486.801.1.2.1.27.1.1.1
A table of objects that augments the standard pethPsePortTable entry by adding the alaPethPsePortPowerMaximum object.
OBJECT-TYPE    
  SEQUENCE OF  
    AlaPethPsePortEntry

alaPethPsePortEntry 1.3.6.1.4.1.6486.801.1.2.1.27.1.1.1.1
A set of objects that display and control the power characteristics of a power Ethernet PSE port.
OBJECT-TYPE    
  AlaPethPsePortEntry  

alaPethPsePortPowerMaximum 1.3.6.1.4.1.6486.801.1.2.1.27.1.1.1.1.1
This object controls maximum amount of power per port.
OBJECT-TYPE    
  INTEGER 3000..30000  

alaPethPsePortPowerActual 1.3.6.1.4.1.6486.801.1.2.1.27.1.1.1.1.2
This object contains the actual amount of power used by a port
OBJECT-TYPE    
  INTEGER 0..30000  

alaPethPsePortPowerStatus 1.3.6.1.4.1.6486.801.1.2.1.27.1.1.1.1.3
This object contains the power status of a port
OBJECT-TYPE    
  INTEGER powerOn(1), powerOff(2)  

alaPethPsePortPowerClass 1.3.6.1.4.1.6486.801.1.2.1.27.1.1.1.1.4
This object controls class of poe device attached on a port. class0 - The device can draw PD power from 0.44W to 12.95W and current less than 5.0 mA. class1 - The device can draw PD power from 0.44W to 3.84W and current 10.5 mA. class2 - The device can draw PD power from 3.84W to 6.49W and current 12.95 mA. class3 - The device can draw PD power from 6.49W to 12.95W and current 28 mA. class4 - This class is reserved for future use. class5 - No Powered Device is connected to this POE port, or the port is powered down.
OBJECT-TYPE    
  INTEGER class0(0), class1(1), class2(2), class3(3), class4(4), class5(5)  

alaPethMainPseTable 1.3.6.1.4.1.6486.801.1.2.1.27.1.1.2
This table augments the standard table PethMainPseTable by allowing the admin status for a group to be set to on/off as well as showing the values for the max power for that group.
OBJECT-TYPE    
  SEQUENCE OF  
    AlaPethMainPseEntry

alaPethMainPseEntry 1.3.6.1.4.1.6486.801.1.2.1.27.1.1.2.1
A set of objects that display and control the Main power of a PSE.
OBJECT-TYPE    
  AlaPethMainPseEntry  

alaPethMainPseAdminStatus 1.3.6.1.4.1.6486.801.1.2.1.27.1.1.2.1.1
The object is used to set the status of the main PSE to ON or OFF.
OBJECT-TYPE    
  INTEGER on(1), off(2)  

alaPethMainPseMaxPower 1.3.6.1.4.1.6486.801.1.2.1.27.1.1.2.1.2
The maximum amount of power allowed for main PSE.
OBJECT-TYPE    
  Integer32 36..800  

alaPethMainPsePriorityDisconnect 1.3.6.1.4.1.6486.801.1.2.1.27.1.1.2.1.3
The object is used to set the priority disconnect of the main PSE to Enabled or Disable.
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

alaPethMainPseCapacitorDetect 1.3.6.1.4.1.6486.801.1.2.1.27.1.1.2.1.4
The object is used to enable or disable the PowerDsine Capacitor detection method.
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

alaPethMainPsePriority 1.3.6.1.4.1.6486.801.1.2.1.27.1.1.2.1.5
The object is set the power down priority for the slot
OBJECT-TYPE    
  INTEGER critical(1), high(2), low(3)  

alaPethMainPseComboPort 1.3.6.1.4.1.6486.801.1.2.1.27.1.1.2.1.6
The object is used to set the combo port option of the main PSE to Enable or Disable.
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

alaPethCompliances 1.3.6.1.4.1.6486.801.1.2.1.27.1.2.1
OBJECT IDENTIFIER    

alaPethGroups 1.3.6.1.4.1.6486.801.1.2.1.27.1.2.2
OBJECT IDENTIFIER    

alaPethCompliance 1.3.6.1.4.1.6486.801.1.2.1.27.1.2.1.1
The pethMainPseGroup is mandatory for systems which implement main power supply within a PSE Device.
MODULE-COMPLIANCE    

alaPethPseCompliance 1.3.6.1.4.1.6486.801.1.2.1.27.1.2.1.2
Describes the requirements for conformance to the PSE
MODULE-COMPLIANCE    

alaPethPsePortGroup 1.3.6.1.4.1.6486.801.1.2.1.27.1.2.2.1
The pethPsePortGroup is mandatory for systems which implement PSE ports.
OBJECT-GROUP    

alaPethMainPseGroup 1.3.6.1.4.1.6486.801.1.2.1.27.1.2.2.2
Main PSE Objects.
OBJECT-GROUP    

alaPethMainTable 1.3.6.1.4.1.6486.801.1.2.1.27.1.3.1
A table of objects that augments the standard pethPsePortTable entry by adding the alaPethPsePortPowerMaximum object.
OBJECT-TYPE    
  SEQUENCE OF  
    AlaPethMainEntry

alaPethMainEntry 1.3.6.1.4.1.6486.801.1.2.1.27.1.3.1.1
A set of objects that display and control the power characteristics of a power Ethernet PSE port.
OBJECT-TYPE    
  AlaPethMainEntry  

alaPethMainIndex 1.3.6.1.4.1.6486.801.1.2.1.27.1.3.1.1.1
This variable uniquely identifies the group to which power Ethernet PSE is connected.Group means (box in the stack, module in a rack) and the value 1 MUST be used for non-modular devices
OBJECT-TYPE    
  Integer32 1..2147483647  

alaPethMainPowerRedundancy 1.3.6.1.4.1.6486.801.1.2.1.27.1.3.1.1.2
This object controls power supply redundancy.
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

alaPethNotificationObjects 1.3.6.1.4.1.6486.801.1.2.1.27.1.1.3
OBJECT IDENTIFIER    

pethSourceSlot 1.3.6.1.4.1.6486.801.1.2.1.27.1.1.3.1
Slot number of generating entity.
OBJECT-TYPE    
  INTEGER 1..64  

pethSourcePort 1.3.6.1.4.1.6486.801.1.2.1.27.1.1.3.2
Port number of generating entity.
OBJECT-TYPE    
  INTEGER 1..48  

pethPwrSupplyConflict 1.3.6.1.4.1.6486.801.1.3.2.17.0.1
Power supply type conflict trap.
NOTIFICATION-TYPE    

pethPwrSupplyNotSupported 1.3.6.1.4.1.6486.801.1.3.2.17.0.2
Power supply not supported trap.
NOTIFICATION-TYPE    

pethTrapsGroup 1.3.6.1.4.1.6486.801.1.2.1.27.1.2.2.3
Notifications for PETH MIB
NOTIFICATION-GROUP    

alaPethTrapObjGroup 1.3.6.1.4.1.6486.801.1.2.1.27.1.2.2.4
Collection of Objects used by PETH Notifications.
OBJECT-GROUP