ACD-DESC-MIB
File:
ACD-DESC-MIB.mib (15047 bytes)
Imported modules
Imported symbols
Defined Types
AcdDescConnectorEntry |
|
SEQUENCE |
|
|
|
|
acdDescConnectorID |
Unsigned32 |
|
|
acdDescConnectorName |
DisplayString |
|
|
acdDescConnectorType |
INTEGER |
|
|
acdDescConnectorPoESupport |
TruthValue |
|
AcdDescPwrEntry |
|
SEQUENCE |
|
|
|
|
acdDescPwrID |
Unsigned32 |
|
|
acdDescPwrName |
DisplayString |
|
|
acdDescPwrType |
INTEGER |
|
|
acdDescPwrPresent |
TruthValue |
|
AcdDescTsEntry |
|
SEQUENCE |
|
|
|
|
acdDescTsID |
Unsigned32 |
|
|
acdDescTsCurrentTemp |
Integer32 |
|
|
acdDescTsFirstThres |
Integer32 |
|
|
acdDescTsFisrtThresPass |
TruthValue |
|
|
acdDescTsSecondThres |
Integer32 |
|
|
acdDescTsSecondThresPass |
TruthValue |
|
Defined Values
acdDesc |
1.3.6.1.4.1.22420.1.1 |
The Accedian Networks device Description MIB. |
MODULE-IDENTITY |
|
|
|
acdDescMacBaseAddr |
1.3.6.1.4.1.22420.1.1.2 |
This is the Base of the EtherNID MAC addresses. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
MacAddress |
|
|
acdDescCpuUsageCurrent |
1.3.6.1.4.1.22420.1.1.20 |
Indicates the current percentage of CPU usage. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Gauge32 |
0..100 |
|
acdDescCpuUsageAverage15 |
1.3.6.1.4.1.22420.1.1.21 |
Indicates the average percentage of CPU usage over the last 15 seconds.
This object range from (0..100). |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Gauge32 |
0..100 |
|
acdDescCpuUsageAverage30 |
1.3.6.1.4.1.22420.1.1.22 |
Indicates the average percentage of CPU usage over the last 30 seconds.
This object range from (0..100). |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Gauge32 |
0..100 |
|
acdDescCpuUsageAverage60 |
1.3.6.1.4.1.22420.1.1.23 |
Indicates the average percentage of CPU usage over the last 60 seconds.
This object range from (0..100). |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Gauge32 |
0..100 |
|
acdDescCpuUsageAverage900 |
1.3.6.1.4.1.22420.1.1.24 |
Indicates the average percentage of CPU usage over the last 900
seconds. This object range from (0..100). |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Gauge32 |
0..100 |
|
acdDescConnectorEntry |
1.3.6.1.4.1.22420.1.1.10.1 |
This is the product connector definition. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
AcdDescConnectorEntry |
|
|
acdDescConnectorID |
1.3.6.1.4.1.22420.1.1.10.1.1 |
Unique value for each connector. Starting to one from left to right. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
Unsigned32 |
1..4294967295 |
|
acdDescConnectorType |
1.3.6.1.4.1.22420.1.1.10.1.3 |
Describe the connector type, for instance an RJ-45 or an SFP. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
other(1), rj45(2), rj45S(3), db9(4), bnc(5), fAUI(6), mAUI(7), fiberSC(8), fiberMIC(9), fiberST(10), telco(11), mtrj(12), hssdc(13), fiberLC(14) |
|
acdDescPwrEntry |
1.3.6.1.4.1.22420.1.1.11.1 |
This is the product available power supplies information. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
AcdDescPwrEntry |
|
|
acdDescPwrID |
1.3.6.1.4.1.22420.1.1.11.1.1 |
Unique value for each power supply. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
Unsigned32 |
1..4294967295 |
|
acdDescPwrType |
1.3.6.1.4.1.22420.1.1.11.1.3 |
Describe the Power Supply type. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
pwrplus5volts(1), pwrminus48volts(2) |
|
acdDescPwrPresent |
1.3.6.1.4.1.22420.1.1.11.1.4 |
This is to indicate if the power supply is present or not. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
TruthValue |
|
|
acdDescTsTable |
1.3.6.1.4.1.22420.1.1.12 |
Table of all Teperature Sensors. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
SEQUENCE OF |
|
|
|
|
AcdDescTsEntry |
|
acdDescTsEntry |
1.3.6.1.4.1.22420.1.1.12.1 |
This is the product available Temperature sensor information. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
AcdDescTsEntry |
|
|
acdDescTsID |
1.3.6.1.4.1.22420.1.1.12.1.1 |
Unique value for each Temperature Sensor. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
Unsigned32 |
1..4294967295 |
|
acdDescTsCurrentTemp |
1.3.6.1.4.1.22420.1.1.12.1.2 |
Current temperature in Celsius around the temperature sensor. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
acdDescTsFirstThres |
1.3.6.1.4.1.22420.1.1.12.1.3 |
Temperature value in Celsius to declare this threshold crossed. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
acdDescTsFisrtThresPass |
1.3.6.1.4.1.22420.1.1.12.1.4 |
This is to indicate if the temperature cross the first threshold. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
TruthValue |
|
|
acdDescTsSecondThres |
1.3.6.1.4.1.22420.1.1.12.1.5 |
Temperature value in Celsius to declare this second threshold crossed. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
acdDescTsSecondThresPass |
1.3.6.1.4.1.22420.1.1.12.1.6 |
This is to indicate if the temperature cross the second threshold. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
TruthValue |
|
|
acdPowerLost |
1.3.6.1.4.1.22420.1.1.0.1 |
The SNMP trap that is generated by a unit when it detect a power lost.
It's the equivalent of the 802.3ah dying gasp. |
Status: current |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|
acdDescGenGroup |
1.3.6.1.4.1.22420.1.1.15.1.2.1 |
. |
Status: current |
Access: read-only |
OBJECT-GROUP |
|
|
|
acdDescPwrGroup |
1.3.6.1.4.1.22420.1.1.15.1.2.3 |
. |
Status: current |
Access: read-only |
OBJECT-GROUP |
|
|
|
acdDescTsGroup |
1.3.6.1.4.1.22420.1.1.15.1.2.4 |
. |
Status: current |
Access: read-only |
OBJECT-GROUP |
|
|
|
acdDescNotificationsGroup |
1.3.6.1.4.1.22420.1.1.15.1.2.5 |
Objects for the Notifications group. |
Status: current |
Access: read-only |
NOTIFICATION-GROUP |
|
|
|
acdAlarmCompliance |
1.3.6.1.4.1.22420.1.1.15.1.1.1 |
The compliance statement for support of the ACD-DESC-MIB module. |
Status: current |
Access: read-only |
MODULE-COMPLIANCE |
|
|
|