ACD-ALARM-MIB

File: ACD-ALARM-MIB.mib (17331 bytes)

Imported modules

SNMPv2-SMI SNMPv2-TC SNMPv2-CONF
SNMPv2-MIB ACCEDIAN-SMI

Imported symbols

MODULE-IDENTITY OBJECT-TYPE NOTIFICATION-TYPE
Unsigned32 DisplayString TruthValue
DateAndTime MODULE-COMPLIANCE OBJECT-GROUP
NOTIFICATION-GROUP sysName acdMibs

Defined Types

AcdAlarmCfgEntry  
SEQUENCE    
  acdAlarmCfgID Unsigned32
  acdAlarmCfgNumber Unsigned32
  acdAlarmCfgDesc DisplayString
  acdAlarmCfgEnable TruthValue
  acdAlarmCfgSeverity INTEGER
  acdAlarmCfgServiceAffecting TruthValue
  acdAlarmCfgExtNumber DisplayString
  acdAlarmCfgConditionType DisplayString
  acdAlarmCfgAMOType DisplayString

AcdAlarmStatusEntry  
SEQUENCE    
  acdAlarmStatusID Unsigned32
  acdAlarmStatusNumber Unsigned32
  acdAlarmStatusOn TruthValue
  acdAlarmStatusLastChange DateAndTime
  acdAlarmStatusMsg DisplayString

Defined Values

acdAlarm 1.3.6.1.4.1.22420.2.1
The alarm Table for this Accedian Networks device.
MODULE-IDENTITY    

acdAlarmMIBObjects 1.3.6.1.4.1.22420.2.1.15
OBJECT IDENTIFIER    

acdAlarmConfig 1.3.6.1.4.1.22420.2.1.15.1
OBJECT IDENTIFIER    

acdAlarmStatus 1.3.6.1.4.1.22420.2.1.15.2
OBJECT IDENTIFIER    

acdAlarmConformance 1.3.6.1.4.1.22420.2.1.15.3
OBJECT IDENTIFIER    

acdAlarmTableTid 1.3.6.1.4.1.22420.2.1.15.4
OBJECT IDENTIFIER    

acdAlarmGenThreshOn 1.3.6.1.4.1.22420.2.1.1
This value represents the Alarm On Hysteris. This is the time since the detection of the On event inside the system versus the report. This is to avoid storm of notifications.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 500..50000  

acdAlarmGenThreshOff 1.3.6.1.4.1.22420.2.1.2
This value represents the Alarm Off Hysteris. This is the time since the detection of the Off event inside the system versus the report. This is to avoid storm of notifications.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 500..50000  

acdAlarmGenLedEnable 1.3.6.1.4.1.22420.2.1.3
This is to Enable the alarms reporting through the LEDs.
Status: current Access: read-write
OBJECT-TYPE    
  TruthValue  

acdAlarmGenSyslogEnable 1.3.6.1.4.1.22420.2.1.4
This is to Enable the alarms reporting through the syslog system.
Status: current Access: read-write
OBJECT-TYPE    
  TruthValue  

acdAlarmGenSNMPEnable 1.3.6.1.4.1.22420.2.1.5
This is to Enable the alarms reporting through the SNMP agent.
Status: current Access: read-write
OBJECT-TYPE    
  TruthValue  

acdAlarmGen8023AHEnable 1.3.6.1.4.1.22420.2.1.6
This is to Enable the alarms reporting through the 802.3AH protocol.
Status: current Access: read-write
OBJECT-TYPE    
  TruthValue  

acdAlarmCfgTable 1.3.6.1.4.1.22420.2.1.10
Table of all alarms.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AcdAlarmCfgEntry

acdAlarmCfgEntry 1.3.6.1.4.1.22420.2.1.10.1
An alarm is an exceptional event that requires user notificaton.
Status: current Access: not-accessible
OBJECT-TYPE    
  AcdAlarmCfgEntry  

acdAlarmCfgID 1.3.6.1.4.1.22420.2.1.10.1.1
Unique value for each alarm. Its value ranges from 1 to MAXINT (4 bytes).
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

acdAlarmCfgNumber 1.3.6.1.4.1.22420.2.1.10.1.2
Unique number that identifies this alarm. Assigned by the unit. The alarm identifier is compose of 3 fields, the module number, the instance number and the error number. The alarm number looks like this: A.BBB.CC and is expressed in decimal, A is the module number, BBB is the instance number (1-999) and CC is the error number (1-99). A module number is assigned for each source of alarm in the system. For example the port module is set to 1, the SFP module is set to 2, the PAA is set to 3 and the environmental is set to 8.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

acdAlarmCfgDesc 1.3.6.1.4.1.22420.2.1.10.1.3
This string is to describe the alarm in a readable way, e.g.: +5Vdc Power supply fail.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..128)  

acdAlarmCfgEnable 1.3.6.1.4.1.22420.2.1.10.1.4
This is to indicate if the alarm is reported or not.
Status: current Access: read-write
OBJECT-TYPE    
  TruthValue  

acdAlarmCfgSeverity 1.3.6.1.4.1.22420.2.1.10.1.5
Accedian Networks classifies alarms into four severity types. These types and their associated decimal codes are, informational(0), minor(1), major(2) and critical(3).
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER info(0), minor(1), major(2), critical(3)  

acdAlarmCfgServiceAffecting 1.3.6.1.4.1.22420.2.1.10.1.6
This is to indicate if the alarm is service affecting or not. This value depends on the utilization of the box. For instance in an application where the monitoring of the traffic is mandatory the link down event on the monitor port is service affecting.
Status: current Access: read-write
OBJECT-TYPE    
  TruthValue  

acdAlarmCfgExtNumber 1.3.6.1.4.1.22420.2.1.10.1.7
Unique number that identifies this alarm. Assigned by the unit. The alarm identifier is compose of 3 fields, the module number, the instance number and the error number. The alarm number looks like this: A.B.C and is expressed in decimal, A is the module number, B is the instance number and C is the error number. A module number is assigned for each source of alarm in the system (see Accedian documentation for more detail).
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..16)  

acdAlarmCfgConditionType 1.3.6.1.4.1.22420.2.1.10.1.8
This is the type of alarm condition.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..32)  

acdAlarmCfgAMOType 1.3.6.1.4.1.22420.2.1.10.1.9
This is the Alarm Maintenance Object.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..128)  

acdAlarmStatusTable 1.3.6.1.4.1.22420.2.1.11
Table of all alarms
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AcdAlarmStatusEntry

acdAlarmStatusEntry 1.3.6.1.4.1.22420.2.1.11.1
An alarm is an exceptional event that requires user notificaton.
Status: current Access: not-accessible
OBJECT-TYPE    
  AcdAlarmStatusEntry  

acdAlarmStatusID 1.3.6.1.4.1.22420.2.1.11.1.1
Unique value for each alarm. Its value ranges from 1 to MAXINT (4 bytes).
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

acdAlarmStatusNumber 1.3.6.1.4.1.22420.2.1.11.1.2
Unique number that identifies this alarm. Assigned by the unit. The alarm identifier is compose of 3 fields, the module number, the instance number and the error number. The alarm number looks like this: AAA.BBB.CC and is expressed in decimal, AAA is the module number, BBB is the instance number (1-999) and CC is the error number (1-99). A module number is assigned for each source of alarm in the system. For example the port module is set to 1, the SFP module is set to 2, the PAA is set to 3 and the environmental is set to 8.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

acdAlarmStatusOn 1.3.6.1.4.1.22420.2.1.11.1.3
This is to indicate if the alarm is On or Off.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

acdAlarmStatusLastChange 1.3.6.1.4.1.22420.2.1.11.1.4
This is the time of the last change for this alarm. A value of zero means that nothing happened to this alarm since the last reboot.
Status: current Access: read-only
OBJECT-TYPE    
  DateAndTime  

acdAlarmStatusMsg 1.3.6.1.4.1.22420.2.1.11.1.5
This string is to add information why the alarm is reported.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..32)  

acdAlarmV2 1.3.6.1.4.1.22420.2.1.12
OBJECT IDENTIFIER    

acdAlarmActiveState 1.3.6.1.4.1.22420.2.1.12.1
The SNMP trap that is generated when an alarm entry crosses its rising threshold and generates an event that is configured for sending SNMP traps.
Status: current Access: read-only
NOTIFICATION-TYPE    

acdAlarmClearState 1.3.6.1.4.1.22420.2.1.12.2
The SNMP trap that is generated when an alarm entry crosses its falling threshold and generates an event that is configured for sending SNMP traps.
Status: current Access: read-only
NOTIFICATION-TYPE    

acdAlarmCfgTableLastChangeTid 1.3.6.1.4.1.22420.2.1.15.4.1
This is the transaction ID of the last change of the acdAlarmCfgTable table. If this value is different since the last read this is indicate a table change.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

acdAlarmStatusTableLastChangeTid 1.3.6.1.4.1.22420.2.1.15.4.2
This is the transaction ID of the last change of the acdAlarmStatusTable table. If this value is different since the last read this is indicate a table change.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

acdAlarmCompliances 1.3.6.1.4.1.22420.2.1.15.3.1
OBJECT IDENTIFIER    

acdAlarmGroups 1.3.6.1.4.1.22420.2.1.15.3.2
OBJECT IDENTIFIER    

acdAlarmGenGroup 1.3.6.1.4.1.22420.2.1.15.3.2.1
.
Status: current Access: read-only
OBJECT-GROUP    

acdAlarmCfgGroup 1.3.6.1.4.1.22420.2.1.15.3.2.2
.
Status: current Access: read-only
OBJECT-GROUP    

acdAlarmStatusGroup 1.3.6.1.4.1.22420.2.1.15.3.2.3
.
Status: current Access: read-only
OBJECT-GROUP    

acdAlarmNotificationsGroup 1.3.6.1.4.1.22420.2.1.15.3.2.4
Objects for the Notifications group.
Status: current Access: read-only
NOTIFICATION-GROUP    

acdAlarmTidGroup 1.3.6.1.4.1.22420.2.1.15.3.2.5
List of scalars to monitior changes in tables.
Status: current Access: read-only
OBJECT-GROUP    

acdAlarmCompliance 1.3.6.1.4.1.22420.2.1.15.3.1.1
The compliance statement for support of the ACD-ALARM-MIB module.
Status: current Access: read-only
MODULE-COMPLIANCE