ACD-ALARM-MIB
File:
ACD-ALARM-MIB.mib (17331 bytes)
Imported modules
Imported symbols
Defined Types
AcdAlarmCfgEntry |
|
SEQUENCE |
|
|
|
|
acdAlarmCfgID |
Unsigned32 |
|
|
acdAlarmCfgNumber |
Unsigned32 |
|
|
acdAlarmCfgDesc |
DisplayString |
|
|
acdAlarmCfgEnable |
TruthValue |
|
|
acdAlarmCfgSeverity |
INTEGER |
|
|
acdAlarmCfgServiceAffecting |
TruthValue |
|
|
acdAlarmCfgExtNumber |
DisplayString |
|
|
acdAlarmCfgConditionType |
DisplayString |
|
|
acdAlarmCfgAMOType |
DisplayString |
|
AcdAlarmStatusEntry |
|
SEQUENCE |
|
|
|
|
acdAlarmStatusID |
Unsigned32 |
|
|
acdAlarmStatusNumber |
Unsigned32 |
|
|
acdAlarmStatusOn |
TruthValue |
|
|
acdAlarmStatusLastChange |
DateAndTime |
|
|
acdAlarmStatusMsg |
DisplayString |
|
Defined Values
acdAlarm |
1.3.6.1.4.1.22420.2.1 |
The alarm Table for this Accedian Networks device. |
MODULE-IDENTITY |
|
|
|
acdAlarmGenThreshOn |
1.3.6.1.4.1.22420.2.1.1 |
This value represents the Alarm On Hysteris. This is the time since the
detection of the On event inside the system versus the report. This is
to avoid storm of notifications. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
Unsigned32 |
500..50000 |
|
acdAlarmGenThreshOff |
1.3.6.1.4.1.22420.2.1.2 |
This value represents the Alarm Off Hysteris. This is the time since the
detection of the Off event inside the system versus the report. This is
to avoid storm of notifications. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
Unsigned32 |
500..50000 |
|
acdAlarmGenLedEnable |
1.3.6.1.4.1.22420.2.1.3 |
This is to Enable the alarms reporting through the LEDs. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
TruthValue |
|
|
acdAlarmGenSyslogEnable |
1.3.6.1.4.1.22420.2.1.4 |
This is to Enable the alarms reporting through the syslog system. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
TruthValue |
|
|
acdAlarmGenSNMPEnable |
1.3.6.1.4.1.22420.2.1.5 |
This is to Enable the alarms reporting through the SNMP agent. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
TruthValue |
|
|
acdAlarmGen8023AHEnable |
1.3.6.1.4.1.22420.2.1.6 |
This is to Enable the alarms reporting through the 802.3AH protocol. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
TruthValue |
|
|
acdAlarmCfgEntry |
1.3.6.1.4.1.22420.2.1.10.1 |
An alarm is an exceptional event that requires user notificaton. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
AcdAlarmCfgEntry |
|
|
acdAlarmCfgID |
1.3.6.1.4.1.22420.2.1.10.1.1 |
Unique value for each alarm. Its value ranges from 1 to
MAXINT (4 bytes). |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Unsigned32 |
|
|
acdAlarmCfgNumber |
1.3.6.1.4.1.22420.2.1.10.1.2 |
Unique number that identifies this alarm. Assigned by the unit. The
alarm identifier is compose of 3 fields, the module number, the instance
number and the error number. The alarm number looks like this:
A.BBB.CC and is expressed in decimal, A is the module number, BBB is
the instance number (1-999) and CC is the error number (1-99). A module
number is assigned for each source of alarm in the system. For example
the port module is set to 1, the SFP module is set to 2, the PAA is set
to 3 and the environmental is set to 8. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Unsigned32 |
|
|
acdAlarmCfgDesc |
1.3.6.1.4.1.22420.2.1.10.1.3 |
This string is to describe the alarm in a readable way, e.g.:
+5Vdc Power supply fail. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(0..128) |
|
acdAlarmCfgEnable |
1.3.6.1.4.1.22420.2.1.10.1.4 |
This is to indicate if the alarm is reported or not. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
TruthValue |
|
|
acdAlarmCfgSeverity |
1.3.6.1.4.1.22420.2.1.10.1.5 |
Accedian Networks classifies alarms into four severity types. These types
and their associated decimal codes are, informational(0), minor(1),
major(2) and critical(3). |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
info(0), minor(1), major(2), critical(3) |
|
acdAlarmCfgServiceAffecting |
1.3.6.1.4.1.22420.2.1.10.1.6 |
This is to indicate if the alarm is service affecting or not. This
value depends on the utilization of the box. For instance in an
application where the monitoring of the traffic is mandatory the link
down event on the monitor port is service affecting. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
TruthValue |
|
|
acdAlarmCfgExtNumber |
1.3.6.1.4.1.22420.2.1.10.1.7 |
Unique number that identifies this alarm. Assigned by the unit. The
alarm identifier is compose of 3 fields, the module number, the instance
number and the error number. The alarm number looks like this:
A.B.C and is expressed in decimal, A is the module number, B is
the instance number and C is the error number. A module number is
assigned for each source of alarm in the system (see Accedian
documentation for more detail). |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(0..16) |
|
acdAlarmCfgAMOType |
1.3.6.1.4.1.22420.2.1.10.1.9 |
This is the Alarm Maintenance Object. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(0..128) |
|
acdAlarmStatusEntry |
1.3.6.1.4.1.22420.2.1.11.1 |
An alarm is an exceptional event that requires user notificaton. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
AcdAlarmStatusEntry |
|
|
acdAlarmStatusID |
1.3.6.1.4.1.22420.2.1.11.1.1 |
Unique value for each alarm. Its value ranges from 1 to
MAXINT (4 bytes). |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Unsigned32 |
|
|
acdAlarmStatusNumber |
1.3.6.1.4.1.22420.2.1.11.1.2 |
Unique number that identifies this alarm. Assigned by the unit. The
alarm identifier is compose of 3 fields, the module number, the instance
number and the error number. The alarm number looks like this:
AAA.BBB.CC and is expressed in decimal, AAA is the module number, BBB is
the instance number (1-999) and CC is the error number (1-99). A module
number is assigned for each source of alarm in the system. For example
the port module is set to 1, the SFP module is set to 2, the PAA is set
to 3 and the environmental is set to 8. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Unsigned32 |
|
|
acdAlarmStatusOn |
1.3.6.1.4.1.22420.2.1.11.1.3 |
This is to indicate if the alarm is On or Off. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
TruthValue |
|
|
acdAlarmStatusLastChange |
1.3.6.1.4.1.22420.2.1.11.1.4 |
This is the time of the last change for this alarm. A value of zero
means that nothing happened to this alarm since the last reboot. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DateAndTime |
|
|
acdAlarmStatusMsg |
1.3.6.1.4.1.22420.2.1.11.1.5 |
This string is to add information why the alarm is reported. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(0..32) |
|
acdAlarmV2 |
1.3.6.1.4.1.22420.2.1.12 |
OBJECT IDENTIFIER |
|
|
|
acdAlarmActiveState |
1.3.6.1.4.1.22420.2.1.12.1 |
The SNMP trap that is generated when an alarm
entry crosses its rising threshold and generates
an event that is configured for sending SNMP
traps. |
Status: current |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|
acdAlarmClearState |
1.3.6.1.4.1.22420.2.1.12.2 |
The SNMP trap that is generated when an alarm
entry crosses its falling threshold and generates
an event that is configured for sending SNMP
traps. |
Status: current |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|
acdAlarmCfgTableLastChangeTid |
1.3.6.1.4.1.22420.2.1.15.4.1 |
This is the transaction ID of the last change of the acdAlarmCfgTable
table. If this value is different since the last read this is indicate
a table change. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Unsigned32 |
|
|
acdAlarmStatusTableLastChangeTid |
1.3.6.1.4.1.22420.2.1.15.4.2 |
This is the transaction ID of the last change of the acdAlarmStatusTable
table. If this value is different since the last read this is indicate
a table change. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Unsigned32 |
|
|
acdAlarmGenGroup |
1.3.6.1.4.1.22420.2.1.15.3.2.1 |
. |
Status: current |
Access: read-only |
OBJECT-GROUP |
|
|
|
acdAlarmCfgGroup |
1.3.6.1.4.1.22420.2.1.15.3.2.2 |
. |
Status: current |
Access: read-only |
OBJECT-GROUP |
|
|
|
acdAlarmStatusGroup |
1.3.6.1.4.1.22420.2.1.15.3.2.3 |
. |
Status: current |
Access: read-only |
OBJECT-GROUP |
|
|
|
acdAlarmNotificationsGroup |
1.3.6.1.4.1.22420.2.1.15.3.2.4 |
Objects for the Notifications group. |
Status: current |
Access: read-only |
NOTIFICATION-GROUP |
|
|
|
acdAlarmTidGroup |
1.3.6.1.4.1.22420.2.1.15.3.2.5 |
List of scalars to monitior changes in tables. |
Status: current |
Access: read-only |
OBJECT-GROUP |
|
|
|
acdAlarmCompliance |
1.3.6.1.4.1.22420.2.1.15.3.1.1 |
The compliance statement for support of the ACD-ALARM-MIB module. |
Status: current |
Access: read-only |
MODULE-COMPLIANCE |
|
|
|