AC-SS7-MIB

File: AC-SS7-MIB.mib (131212 bytes)

Imported modules

SNMPv2-SMI SNMPv2-TC RFC1155-SMI
SNMP-FRAMEWORK-MIB INET-ADDRESS-MIB SNMPv2-CONF
AUDIOCODES-TYPES-MIB

Imported symbols

OBJECT-TYPE MODULE-IDENTITY TAddress
DisplayString DateAndTime TEXTUAL-CONVENTION
IpAddress Unsigned32 Integer32
enterprises RowStatus SnmpAdminString
InetAddressType InetAddress MODULE-COMPLIANCE
OBJECT-GROUP NOTIFICATION-GROUP audioCodes
acRegistrations acGeneric acProducts
acBoardMibs

Defined Types

AcSS7MTP2AttribEntry  
SEQUENCE    
  acSS7MTP2AttribIndex Unsigned32
  acSS7MTP2AttribIsUsed INTEGER
  acSS7MTP2AttribLinkRate SnmpAdminString
  acSS7MTP2AttribErrorCorectionMethod SnmpAdminString
  acSS7MTP2AttribIacCp Unsigned32
  acSS7MTP2AttribSUERMThreshold Unsigned32
  acSS7MTP2AttribAERMNormalThreshold Unsigned32
  acSS7MTP2AttribAERMEmerglThreshold Unsigned32
  acSS7MTP2AttribSUERMSigUnitDThreshold Unsigned32
  acSS7MTP2AttribOctetCounting Unsigned32
  acSS7MTP2AttribTimerT1 Unsigned32
  acSS7MTP2AttribTimerT2 Unsigned32
  acSS7MTP2AttribTimerT3 Unsigned32
  acSS7MTP2AttribTimerT4Normal Unsigned32
  acSS7MTP2AttribTimerT4Emerg Unsigned32
  acSS7MTP2AttribTimerT5 Unsigned32
  acSS7MTP2AttribTimerT6 Unsigned32
  acSS7MTP2AttribTimerT7 Unsigned32
  acSS7MTP2AttribLSSULength Unsigned32
  acSS7MTP2AttribPcrN2 Unsigned32
  acSS7MTP2AttribRowStatus RowStatus

AcSS7SignalingNodeTimersEntry  
SEQUENCE    
  acSS7SignalingNodeTimersIndex Unsigned32
  acSS7SignalingNodeTimersIsUsed INTEGER
  acSS7SignalingNodeTimersAction INTEGER
  acSS7SignalingNodeTimersActionResult INTEGER
  acSS7SignalingNodeTimersName SnmpAdminString
  acSS7SignalingNodeTimersT6 Unsigned32
  acSS7SignalingNodeTimersT8 Unsigned32
  acSS7SignalingNodeTimersT10 Unsigned32
  acSS7SignalingNodeTimersT11 Unsigned32
  acSS7SignalingNodeTimersT15 Unsigned32
  acSS7SignalingNodeTimersT16 Unsigned32
  acSS7SignalingNodeTimersT18ITU Unsigned32
  acSS7SignalingNodeTimersT19ITU Unsigned32
  acSS7SignalingNodeTimersT20ITU Unsigned32
  acSS7SignalingNodeTimersT21ITU Unsigned32
  acSS7SignalingNodeTimersT24ITU Unsigned32
  acSS7SignalingNodeTimersT22ANSI Unsigned32
  acSS7SignalingNodeTimersT23ANSI Unsigned32
  acSS7SignalingNodeTimersT24ANSI Unsigned32
  acSS7SignalingNodeTimersT25ANSI Unsigned32
  acSS7SignalingNodeTimersT26ANSI Unsigned32
  acSS7SignalingNodeTimersT27ANSI Unsigned32
  acSS7SignalingNodeTimersT28ANSI Unsigned32
  acSS7SignalingNodeTimersT29ANSI Unsigned32
  acSS7SignalingNodeTimersT30ANSI Unsigned32

AcSS7LinkSetTimersEntry  
SEQUENCE    
  acSS7LinkSetTimersIndex Unsigned32
  acSS7LinkSetTimersIsUsed INTEGER
  acSS7LinkSetTimersAction INTEGER
  acSS7LinkSetTimersActionResult INTEGER
  acSS7LinkSetTimersName SnmpAdminString
  acSS7LinkSetTimersT1SLT Unsigned32
  acSS7LinkSetTimersT2SLT Unsigned32
  acSS7LinkSetTimersT1 Unsigned32
  acSS7LinkSetTimersT2 Unsigned32
  acSS7LinkSetTimersT3 Unsigned32
  acSS7LinkSetTimersT4 Unsigned32
  acSS7LinkSetTimersT5 Unsigned32
  acSS7LinkSetTimersT7 Unsigned32
  acSS7LinkSetTimersT12 Unsigned32
  acSS7LinkSetTimersT13 Unsigned32
  acSS7LinkSetTimersT14 Unsigned32
  acSS7LinkSetTimersT17 Unsigned32
  acSS7LinkSetTimersT20ANSI Unsigned32
  acSS7LinkSetTimersT21ANSI Unsigned32
  acSS7LinkSetTimersT22ITU Unsigned32
  acSS7LinkSetTimersT23ITU Unsigned32

AcSS7LinkCommonEntry  
SEQUENCE    
  acSS7LinkCommonIndex Unsigned32
  acSS7LinkCommonRowStatus RowStatus
  acSS7LinkCommonAction INTEGER
  acSS7LinkCommonActionResult INTEGER
  acSS7LinkCommonName SnmpAdminString
  acSS7LinkCommonAdminState INTEGER
  acSS7LinkCommonOperState INTEGER
  acSS7LinkCommonTraceLevel INTEGER
  acSS7LinkCommonL2TypeSelector INTEGER
  acSS7LinkCommonL3TypeSelector INTEGER
  acSS7LinkCommonVariant INTEGER
  acSS7LinkCommonMtcBusy INTEGER
  acSS7LinkCommonRdcyBoardNum INTEGER
  acSS7LinkCommonMonSuFilterRequest INTEGER

AcSS7LinkTDMEntry  
SEQUENCE    
  acSS7LinkTDMTrunkNumber Integer32
  acSS7LinkTDMTimeSlotNumber Unsigned32
  acSS7LinkTDMInhibit INTEGER
  acSS7LinkTDMMtp2Atts INTEGER
  acSS7LinkTDMCongestionLowMark Unsigned32
  acSS7LinkTDMCongestionHighMark Unsigned32
  acSS7LinkTDMBlock INTEGER

AcSS7LinkSigTranEntry  
SEQUENCE    
  acSS7LinkSigTranGroupId Integer32
  acSS7LinkSigTranIfid Integer32

AcSS7LinkATMEntry  
SEQUENCE    
  acSS7LinkATMSAALLinkProfileNum Unsigned32
  acSS7LinkATMSAALLinkType INTEGER
  acSS7LinkATMSAALLinkInterfaceNum Unsigned32
  acSS7LinkATMSAALLinkVPI Unsigned32
  acSS7LinkATMSAALLinkVCI Unsigned32

AcSS7LinkTNLEntry  
SEQUENCE    
  acSS7LinkTNLOtherSideLinkNum Unsigned32
  acSS7LinkTNLAlignmentMode INTEGER
  acSS7LinkTNLCongestionMode INTEGER
  acSS7LinkTNLWaitStartCompTimer Unsigned32
  acSS7LinkTNLOosStartDelayTimer Unsigned32
  acSS7LinkTNLWaitOtherSideInsvTimer Unsigned32

AcSS7SignalingNodeEntry  
SEQUENCE    
  acSS7SignalingNodeIndex Unsigned32
  acSS7SignalingNodeRowStatus RowStatus
  acSS7SignalingNodeAction INTEGER
  acSS7SignalingNodeActionResult INTEGER
  acSS7SignalingNodeName SnmpAdminString
  acSS7SignalingNodeTraceLevel INTEGER
  acSS7SignalingNodeAdminState INTEGER
  acSS7SignalingNodeOperState INTEGER
  acSS7SignalingNodeMtcBusy INTEGER
  acSS7SignalingNodeVariant INTEGER
  acSS7SignalingNodeNwIndicator INTEGER
  acSS7SignalingNodeSpStp INTEGER
  acSS7SignalingNodeTfc INTEGER
  acSS7SignalingNodeOpc Unsigned32
  acSS7SignalingNodeRouteSetCongestionWindow Unsigned32
  acSS7SignalingNodeTimersIdx INTEGER
  acSS7SignalingNodeIsupApp INTEGER
  acSS7SignalingNodeSccpApp INTEGER
  acSS7SignalingNodeBisupApp INTEGER
  acSS7SignalingNodeAlcapApp INTEGER
  acSS7SignalingNodeRdcyOpc Unsigned32
  acSS7SignalingNodeTupApp INTEGER
  acSS7SignalingNodeBiccApp INTEGER

AcSS7LinkSetEntry  
SEQUENCE    
  acSS7LinkSetSNIndex Unsigned32
  acSS7LinkSetLksetIndex Unsigned32
  acSS7LinkSetRowStatus RowStatus
  acSS7LinkSetAction INTEGER
  acSS7LinkSetActionResult INTEGER
  acSS7LinkSetName SnmpAdminString
  acSS7LinkSetAdminState INTEGER
  acSS7LinkSetOperState INTEGER
  acSS7LinkSetMtcBusyState INTEGER
  acSS7LinkSetDPC Unsigned32
  acSS7LinkSetLinksMask Unsigned32
  acSS7LinkSetLinksAltMask Unsigned32
  acSS7LinkSetTimersIdx INTEGER

AcSS7LinkSetLinkEntry  
SEQUENCE    
  acSS7LinkSetLinkSNIndex Unsigned32
  acSS7LinkSetLinkLinksetIndex Unsigned32
  acSS7LinkSetLinkInnerLinkIndex Unsigned32
  acSS7LinkSetLinkRowStatus RowStatus
  acSS7LinkSetLinkAction INTEGER
  acSS7LinkSetLinkActionResult INTEGER
  acSS7LinkSetLinkLinkNo Unsigned32
  acSS7LinkSetLinkLinkSlc Unsigned32

AcSS7RouteSetEntry  
SEQUENCE    
  acSS7RouteSetSNIndex Unsigned32
  acSS7RouteSetIndex Unsigned32
  acSS7RouteSetRowStatus RowStatus
  acSS7RouteSetAction INTEGER
  acSS7RouteSetActionResult INTEGER
  acSS7RouteSetName SnmpAdminString
  acSS7RouteSetAdminState INTEGER
  acSS7RouteSetOperState INTEGER
  acSS7RouteSetDPC Unsigned32
  acSS7RouteSetRouteMask Unsigned32

AcSS7RouteSetRouteEntry  
SEQUENCE    
  acSS7RouteSetRouteSNIndex Unsigned32
  acSS7RouteSetRouteRoutesetIndex Unsigned32
  acSS7RouteSetRouteInnerRouteIndex Unsigned32
  acSS7RouteSetRouteRowStatus RowStatus
  acSS7RouteSetRouteAction INTEGER
  acSS7RouteSetRouteActionResult INTEGER
  acSS7RouteSetRouteLinkSetNo Unsigned32
  acSS7RouteSetRoutePriority Unsigned32

AcSS7APCEntry  
SEQUENCE    
  acSS7APCSNIndex Unsigned32
  acSS7APCIndex Unsigned32
  acSS7APCRowStatus RowStatus
  acSS7APCAction INTEGER
  acSS7APCActionResult INTEGER
  acSS7APCPC Unsigned32
  acSS7APCSNI Unsigned32
  acSS7APCName SnmpAdminString
  acSS7APCMtcBusy INTEGER
  acSS7APCAdminState INTEGER
  acSS7APCOperState INTEGER

AcSS7SigTranIFGroupEntry  
SEQUENCE    
  acSS7SigTranIFGroupIndex Unsigned32
  acSS7SigTranIFGroupRowStatus RowStatus
  acSS7SigTranIFGroupAction INTEGER
  acSS7SigTranIFGroupActionResult Unsigned32
  acSS7SigTranIFGroupId Unsigned32
  acSS7SigTranIFGroupSgMgc INTEGER
  acSS7SigTranIFGroupSignalingLayer INTEGER
  acSS7SigTranIFGroupTrafMode INTEGER
  acSS7SigTranIFGroupRecovTimer Unsigned32
  acSS7SigTranIFGroupAckTimer Unsigned32
  acSS7SigTranIFGroupHBTimer Unsigned32
  acSS7SigTranIFGroupMinAsp Unsigned32
  acSS7SigTranIFGroupBehavior Unsigned32
  acSS7SigTranIFGroupSCTPInst Unsigned32
  acSS7SigTranIFGroupSCTPLocalPort Unsigned32
  acSS7SigTranIFGroupNetwork INTEGER
  acSS7SigTranIFGroupSCTPDestPort Unsigned32
  acSS7SigTranIFGroupDestIp IpAddress
  acSS7SigTranIFGroupSCTPMaxInbStreams Unsigned32
  acSS7SigTranIFGroupSCTPMaxOutbStreams Unsigned32
  acSS7SigTranIFGroupRdcyBoardNum Unsigned32
  acSS7SigTranIFGroupRoutingContextIndex Integer32
  acSS7SigTranIFGroupRoutingContextValue Integer32
  acSS7SigTranIFGroupNetworkAppearance Integer32

AcSS7SigTranIFIDEntry  
SEQUENCE    
  acSS7SigTranIFIDIndex Unsigned32
  acSS7SigTranIFIDRowStatus RowStatus
  acSS7SigTranIFIDAction INTEGER
  acSS7SigTranIFIDActionResult Unsigned32
  acSS7SigTranIFIDValue Unsigned32
  acSS7SigTranIFIDName SnmpAdminString
  acSS7SigTranIFIDOwnerGroup Integer32
  acSS7SigTranIFIDSignalingLayer INTEGER
  acSS7SigTranIFIDNai Integer32
  acSS7SigTranIFIDM3UASpc Unsigned32

AcSS7M3UAStaticRoutingEntry  
SEQUENCE    
  acSS7M3UAStaticRoutingIndex Unsigned32
  acSS7M3UAStaticRoutingRowStatus RowStatus
  acSS7M3UAStaticRoutingAction INTEGER
  acSS7M3UAStaticRoutingActionResult Unsigned32
  acSS7M3UAStaticRoutingOwnerInterfaceGroup Unsigned32
  acSS7M3UAStaticRoutingRC Unsigned32
  acSS7M3UAStaticRoutingDestinationPointCode Unsigned32
  acSS7M3UAStaticRoutingNetworkAppearence Unsigned32
  acSS7M3UAStaticRoutingSeriviceIndicatorList Unsigned32
  acSS7M3UAStaticRoutingOPC1 Unsigned32
  acSS7M3UAStaticRoutingOPC2 Unsigned32
  acSS7M3UAStaticRoutingOPC3 Unsigned32
  acSS7M3UAStaticRoutingOPC4 Unsigned32
  acSS7M3UAStaticRoutingLowerCICValue1 Unsigned32
  acSS7M3UAStaticRoutingUpperCICValue1 Unsigned32
  acSS7M3UAStaticRoutingLowerCICValue2 Unsigned32
  acSS7M3UAStaticRoutingUpperCICValue2 Unsigned32
  acSS7M3UAStaticRoutingLowerCICValue3 Unsigned32
  acSS7M3UAStaticRoutingUpperCICValue3 Unsigned32
  acSS7M3UAStaticRoutingLowerCICValue4 Unsigned32
  acSS7M3UAStaticRoutingUpperCICValue4 Unsigned32

AcSS7SigTranRoutingContextEntry  
SEQUENCE    
  acSS7SigTranRoutingContextIndex Unsigned32
  acSS7SigTranRoutingContextInnerIndex Unsigned32
  acSS7SigTranRoutingContextRowStatus RowStatus
  acSS7SigTranRoutingContextAction INTEGER
  acSS7SigTranRoutingContextActionResult Unsigned32
  acSS7SigTranRoutingContextSnIdx Unsigned32
  acSS7SigTranRoutingContextSpc Integer32
  acSS7SigTranRoutingContextOpc1 Integer32
  acSS7SigTranRoutingContextOpc2 Integer32
  acSS7SigTranRoutingContextOpc3 Integer32
  acSS7SigTranRoutingContextOpc4 Integer32
  acSS7SigTranRoutingContextSi1 Integer32
  acSS7SigTranRoutingContextSi2 Integer32
  acSS7SigTranRoutingContextSi3 Integer32
  acSS7SigTranRoutingContextSi4 Integer32

AcSS7RedundantSNEntry  
SEQUENCE    
  acSS7RedundantSNBoardIndex Unsigned32
  acSS7RedundantSNIndex Unsigned32
  acSS7RedundantSNRowStatus RowStatus
  acSS7RedundantSNAction Unsigned32
  acSS7RedundantSNActionRes Unsigned32
  acSS7RedundantSNBoardIp IpAddress
  acSS7RedundantSNOPC Unsigned32
  acSS7RedundantSNALCAPOPC Unsigned32

Defined Values

acSS7 1.3.6.1.4.1.5003.9.10.12
Tok_String
MODULE-IDENTITY    

acSS7Configuration 1.3.6.1.4.1.5003.9.10.12.1
OBJECT IDENTIFIER    

acSS7MTP2 1.3.6.1.4.1.5003.9.10.12.1.1
OBJECT IDENTIFIER    

acSS7MTP2M3bSlDiscardCongThreshold 1.3.6.1.4.1.5003.9.10.12.1.1.1
This parameter concerns feature that prevents uncontrolled increase of the MTP2 Transmit queue when the upper levels ignores the usual flow control mechanism. Any new SL_TX_MSU_RQ is discarded when the number of msu queued on the TB or RTB overtakes the threshold. Value 0, means that this feature is not activated. Access: Offline. AC INI-Param: SS7M3bSlDiscardCongThreshold
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 0..255  

acSS7MTP2AttribTable 1.3.6.1.4.1.5003.9.10.12.1.1.21
Tok_String
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AcSS7MTP2AttribEntry

acSS7MTP2AttribEntry 1.3.6.1.4.1.5003.9.10.12.1.1.21.1
Tok_String
Status: current Access: not-accessible
OBJECT-TYPE    
  AcSS7MTP2AttribEntry  

acSS7MTP2AttribIndex 1.3.6.1.4.1.5003.9.10.12.1.1.21.1.1
Index Field for line. AC INI-Param: SS7Mtp2Parms_Index
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32 0..3  

acSS7MTP2AttribIsUsed 1.3.6.1.4.1.5003.9.10.12.1.1.21.1.2
Is the row used by alink. If it is the entrow will be read. AC INI-Param: N/A
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER no(0), yes(1)  

acSS7MTP2AttribLinkRate 1.3.6.1.4.1.5003.9.10.12.1.1.21.1.3
Defines the SS7 SLI Link Rate. Choose either: A = 64 kbps D = 56 kbps 0 = 64 kbps. Access: Online. AC INI-Param: SS7Mtp2Parms_LinkRate
Status: current Access: read-create
OBJECT-TYPE    
  SnmpAdminString Size(0..1)  

acSS7MTP2AttribErrorCorectionMethod 1.3.6.1.4.1.5003.9.10.12.1.1.21.1.4
Defines the SLI error correction method. B = Basic P = PCR (Preventive Cyclic Retransmission). Access: Online. AC INI-Param: SS7Mtp2Parms_ErrorCorrectionMethod
Status: current Access: read-create
OBJECT-TYPE    
  SnmpAdminString Size(0..1)  

acSS7MTP2AttribIacCp 1.3.6.1.4.1.5003.9.10.12.1.1.21.1.5
Defines the number of aborted proving attempts before sending an out-of-service to MTP-3. Access: Online. AC INI-Param: SS7Mtp2Parms_IacCp
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32 0..10  

acSS7MTP2AttribSUERMThreshold 1.3.6.1.4.1.5003.9.10.12.1.1.21.1.6
Defines the SS7 SUERM (Signal Unit Error Rate Monitor) T threshold. Access: Online. AC INI-Param: SS7Mtp2Parms_SuermT
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32 0..256  

acSS7MTP2AttribAERMNormalThreshold 1.3.6.1.4.1.5003.9.10.12.1.1.21.1.7
Normal AERM (alignment error rate monitor) threshold [0 to 20]. Access: Online. AC INI-Param: SS7Mtp2Parms_AermTin
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32 0..20  

acSS7MTP2AttribAERMEmerglThreshold 1.3.6.1.4.1.5003.9.10.12.1.1.21.1.8
Emergency AERM (alignment error rate monitor) threshold [0 to 10]. Access: Online. AC INI-Param: SS7Mtp2Parms_AermTie
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32 0..10  

acSS7MTP2AttribSUERMSigUnitDThreshold 1.3.6.1.4.1.5003.9.10.12.1.1.21.1.9
Defines the SS7 Signal Unit error rate monitor D threshold. Access: Online. AC INI-Param: SS7Mtp2Parms_SuermSuD
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32 0..256  

acSS7MTP2AttribOctetCounting 1.3.6.1.4.1.5003.9.10.12.1.1.21.1.10
Defines the SS7 MTP2 Octet received while the OCTET is in counting mode (# of Octets received - N Octets - while in Octet counting mode). Access: Online. AC INI-Param: SS7Mtp2Parms_OctetCounting
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32 0..256  

acSS7MTP2AttribTimerT1 1.3.6.1.4.1.5003.9.10.12.1.1.21.1.11
Defines the SS7 MTP2 T1 alignment ready timer (in msecs). Access: Online. AC INI-Param: SS7Mtp2Parms_T1
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32 0..100000  

acSS7MTP2AttribTimerT2 1.3.6.1.4.1.5003.9.10.12.1.1.21.1.12
Defines the SS7 MTP2 T2 unaligned timer (in msecs). Access: Online. AC INI-Param: SS7Mtp2Parms_T2
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32 0..200000  

acSS7MTP2AttribTimerT3 1.3.6.1.4.1.5003.9.10.12.1.1.21.1.13
Defines the SS7 MTP2 T3 timer aligned. Access: Online. AC INI-Param: SS7Mtp2Parms_T3
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32 0..20000  

acSS7MTP2AttribTimerT4Normal 1.3.6.1.4.1.5003.9.10.12.1.1.21.1.14
Defines the SS7 MTP2 T4n Normal proving period timer. Access: Online. AC INI-Param: SS7Mtp2Parms_T4n
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32 0..15000  

acSS7MTP2AttribTimerT4Emerg 1.3.6.1.4.1.5003.9.10.12.1.1.21.1.15
Defines the SS7 MTP2 T4e Emergency proving period timer (msec). Access: Online. AC INI-Param: SS7Mtp2Parms_T4e
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32 0..5000  

acSS7MTP2AttribTimerT5 1.3.6.1.4.1.5003.9.10.12.1.1.21.1.16
Defines the SS7 MTP2 Sending SIB timer. Access: Online. AC INI-Param: SS7Mtp2Parms_T5
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32 0..2400  

acSS7MTP2AttribTimerT6 1.3.6.1.4.1.5003.9.10.12.1.1.21.1.17
Defines the SS7 MTP2 Remote Congestion timer (in msec). Access: Online. AC INI-Param: SS7Mtp2Parms_T6
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32 0..10000  

acSS7MTP2AttribTimerT7 1.3.6.1.4.1.5003.9.10.12.1.1.21.1.18
Defines the SS7 MTP2 excessive delay of the ack timer (in msec). Access: Online. AC INI-Param: SS7Mtp2Parms_T7
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32 0..5000  

acSS7MTP2AttribLSSULength 1.3.6.1.4.1.5003.9.10.12.1.1.21.1.19
Defines the SS7 MTP2 LSSU length as 1 or 2 (bytes). Access: Online. AC INI-Param: SS7Mtp2Parms_LssuLength
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32 1..2  

acSS7MTP2AttribPcrN2 1.3.6.1.4.1.5003.9.10.12.1.1.21.1.20
This parameter is used to define Preventive Cyclic Retransmission - the number of message signal unit octets available for retransmission (ITU-T Q703 6.4 - Forced retransmission). Access: Online. AC INI-Param: SS7Mtp2Parms_PcrN2
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32 0..512  

acSS7MTP2AttribRowStatus 1.3.6.1.4.1.5003.9.10.12.1.1.21.1.21
ROWSTATUS Field for line. AC INI-Param: N/A
Status: obsolete Access: read-create
OBJECT-TYPE    
  RowStatus  

acSS7Timers 1.3.6.1.4.1.5003.9.10.12.1.2
OBJECT IDENTIFIER    

acSS7SignalingNodeTimersTable 1.3.6.1.4.1.5003.9.10.12.1.2.21
Tok_String
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AcSS7SignalingNodeTimersEntry

acSS7SignalingNodeTimersEntry 1.3.6.1.4.1.5003.9.10.12.1.2.21.1
Tok_String
Status: current Access: not-accessible
OBJECT-TYPE    
  AcSS7SignalingNodeTimersEntry  

acSS7SignalingNodeTimersIndex 1.3.6.1.4.1.5003.9.10.12.1.2.21.1.1
Index Field for line. AC INI-Param: SS7_SNTIMERS_INDEX
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32 0..4  

acSS7SignalingNodeTimersIsUsed 1.3.6.1.4.1.5003.9.10.12.1.2.21.1.2
AC INI-Param: N/A
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER no(0), yes(1)  

acSS7SignalingNodeTimersAction 1.3.6.1.4.1.5003.9.10.12.1.2.21.1.3
management Field for ACTIONS. AC INI-Param: SS7_SNTIMERS_ACTION
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER none(0)  

acSS7SignalingNodeTimersActionResult 1.3.6.1.4.1.5003.9.10.12.1.2.21.1.4
management Field for ACTIONS RESULT. AC INI-Param: SS7_SNTIMERS_ACTION_RESULT
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER succeeded(0), inProgress(1), failed(2)  

acSS7SignalingNodeTimersName 1.3.6.1.4.1.5003.9.10.12.1.2.21.1.5
String name for SN timer-set. Access: Online. AC INI-Param: SS7_SNTIMERS_NAME
Status: current Access: read-write
OBJECT-TYPE    
  SnmpAdminString Size(0..15)  

acSS7SignalingNodeTimersT6 1.3.6.1.4.1.5003.9.10.12.1.2.21.1.6
Delay to avoid message mis-sequencing on controlled rerouting. Access: Online. AC INI-Param: SS7_SNTIMERS_T6
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 500..2147483647  

acSS7SignalingNodeTimersT8 1.3.6.1.4.1.5003.9.10.12.1.2.21.1.7
Transfer prohibited inhibition timer (transient solution). Access: Online. AC INI-Param: SS7_SNTIMERS_T8
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 500..2147483647  

acSS7SignalingNodeTimersT10 1.3.6.1.4.1.5003.9.10.12.1.2.21.1.8
Waiting to repeat signalling route set test message. Access: Online. AC INI-Param: SS7_SNTIMERS_T10
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 500..2147483647  

acSS7SignalingNodeTimersT11 1.3.6.1.4.1.5003.9.10.12.1.2.21.1.9
Transfer restricted timer. Access: Online. AC INI-Param: SS7_SNTIMERS_T11
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 500..2147483647  

acSS7SignalingNodeTimersT15 1.3.6.1.4.1.5003.9.10.12.1.2.21.1.10
Waiting to start signalling route set congestion test. Access: Online. AC INI-Param: SS7_SNTIMERS_T15
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 500..2147483647  

acSS7SignalingNodeTimersT16 1.3.6.1.4.1.5003.9.10.12.1.2.21.1.11
Waiting for route set congestion status update. Access: Online. AC INI-Param: SS7_SNTIMERS_T16
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 500..2147483647  

acSS7SignalingNodeTimersT18ITU 1.3.6.1.4.1.5003.9.10.12.1.2.21.1.12
Timer within a signalling point whose MTP restarts for supervising link and link set activation as well as the receipt of routing information. Access: Online. AC INI-Param: SS7_SNTIMERS_T18_ITU
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 500..2147483647  

acSS7SignalingNodeTimersT19ITU 1.3.6.1.4.1.5003.9.10.12.1.2.21.1.13
Supervision timer during MTP restart to avoid possible ping-pong of TFP, TFR and TRA messages. Access: Online. AC INI-Param: SS7_SNTIMERS_T19_ITU
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 500..2147483647  

acSS7SignalingNodeTimersT20ITU 1.3.6.1.4.1.5003.9.10.12.1.2.21.1.14
Overall MTP restart timer at the signalling point whose MTP restarts. Access: Online. AC INI-Param: SS7_SNTIMERS_T20_ITU
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 500..2147483647  

acSS7SignalingNodeTimersT21ITU 1.3.6.1.4.1.5003.9.10.12.1.2.21.1.15
Overall MTP restart timer at a signalling point adjacent to one whose MTP restarts. Access: Online. AC INI-Param: SS7_SNTIMERS_T21_ITU
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 500..2147483647  

acSS7SignalingNodeTimersT24ITU 1.3.6.1.4.1.5003.9.10.12.1.2.21.1.16
Stabilising timer after removal of local processor outage, used in LPO latching to RPO (national option). Access: Online. AC INI-Param: SS7_SNTIMERS_T24_ITU
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 500..2147483647  

acSS7SignalingNodeTimersT22ANSI 1.3.6.1.4.1.5003.9.10.12.1.2.21.1.17
Timer at restarting SP waiting for signalling links to bacome available. Access: Online. AC INI-Param: SS7_SNTIMERS_T22_ANSI
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 500..2147483647  

acSS7SignalingNodeTimersT23ANSI 1.3.6.1.4.1.5003.9.10.12.1.2.21.1.18
Timer at restarting SP, started after T22, waiting to receive all traffic restart allowed messages. Access: Online. AC INI-Param: SS7_SNTIMERS_T23_ANSI
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 500..2147483647  

acSS7SignalingNodeTimersT24ANSI 1.3.6.1.4.1.5003.9.10.12.1.2.21.1.19
Timer at restarting SP with transfer function, started after T23, waiting to broadcast all traffic restart allowed messages. Access: Online. AC INI-Param: SS7_SNTIMERS_T24_ANSI
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 500..2147483647  

acSS7SignalingNodeTimersT25ANSI 1.3.6.1.4.1.5003.9.10.12.1.2.21.1.20
Timer at SP adjacent to restarting SP waiting for traffic restart allowed message. Access: Online. AC INI-Param: SS7_SNTIMERS_T25_ANSI
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 500..2147483647  

acSS7SignalingNodeTimersT26ANSI 1.3.6.1.4.1.5003.9.10.12.1.2.21.1.21
Timer at restarting SP waiting to repeat traffic restart waiting message. Access: Online. AC INI-Param: SS7_SNTIMERS_T26_ANSI
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 500..2147483647  

acSS7SignalingNodeTimersT27ANSI 1.3.6.1.4.1.5003.9.10.12.1.2.21.1.22
This parameter is used to define the minimum duration of unavailability for a full restart. Access: Online. AC INI-Param: SS7_SNTIMERS_T27_ANSI
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 500..2147483647  

acSS7SignalingNodeTimersT28ANSI 1.3.6.1.4.1.5003.9.10.12.1.2.21.1.23
Timer at SP adjacent to restarting SP waiting for traffic restart waiting message. Access: Online. AC INI-Param: SS7_SNTIMERS_T28_ANSI
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 500..2147483647  

acSS7SignalingNodeTimersT29ANSI 1.3.6.1.4.1.5003.9.10.12.1.2.21.1.24
Timer started when TRA sent in response to unexpected TRA or TRW. Access: Online. AC INI-Param: SS7_SNTIMERS_T29_ANSI
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 500..2147483647  

acSS7SignalingNodeTimersT30ANSI 1.3.6.1.4.1.5003.9.10.12.1.2.21.1.25
Timer to limit sending of TFPs and TFRs in response to unexpected TRA or TRW. Access: Online. AC INI-Param: SS7_SNTIMERS_T30_ANSI
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 500..2147483647  

acSS7LinkSetTimersTable 1.3.6.1.4.1.5003.9.10.12.1.2.22
Tok_String
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AcSS7LinkSetTimersEntry

acSS7LinkSetTimersEntry 1.3.6.1.4.1.5003.9.10.12.1.2.22.1
Tok_String
Status: current Access: not-accessible
OBJECT-TYPE    
  AcSS7LinkSetTimersEntry  

acSS7LinkSetTimersIndex 1.3.6.1.4.1.5003.9.10.12.1.2.22.1.1
Index Field for line. AC INI-Param: acSS7LKSETTIMERS_PS_PARAMETER_INDEX
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32 0..4  

acSS7LinkSetTimersIsUsed 1.3.6.1.4.1.5003.9.10.12.1.2.22.1.2
AC INI-Param: N/A
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER no(0), yes(1)  

acSS7LinkSetTimersAction 1.3.6.1.4.1.5003.9.10.12.1.2.22.1.3
management Field for ACTIONS. AC INI-Param: SS7_LKSETTIMERS_ACTION
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER none(0)  

acSS7LinkSetTimersActionResult 1.3.6.1.4.1.5003.9.10.12.1.2.22.1.4
management Field for ACTIONS RESULT. AC INI-Param: SS7_LKSETTIMERS_ACTION_RESULT
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER succeeded(0), inProgress(1), failed(2)  

acSS7LinkSetTimersName 1.3.6.1.4.1.5003.9.10.12.1.2.22.1.5
String name for Linkset timer-set. Access: Online. AC INI-Param: SS7_LKSETTIMERS_NAME
Status: current Access: read-write
OBJECT-TYPE    
  SnmpAdminString Size(0..15)  

acSS7LinkSetTimersT1SLT 1.3.6.1.4.1.5003.9.10.12.1.2.22.1.6
Supervision timer for signalling link test acknowledgement message. Access: Online. AC INI-Param: SS7_LKSETTIMERS_T1SLT
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 500..2147483647  

acSS7LinkSetTimersT2SLT 1.3.6.1.4.1.5003.9.10.12.1.2.22.1.7
Interval timer for sending signalling link test messages. Access: Online. AC INI-Param: SS7_LKSETTIMERS_T2SLT
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 500..2147483647  

acSS7LinkSetTimersT1 1.3.6.1.4.1.5003.9.10.12.1.2.22.1.8
Delay to avoid message mis-sequencing on changeover. Access: Online. AC INI-Param: SS7_LKSETTIMERS_T1
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 500..2147483647  

acSS7LinkSetTimersT2 1.3.6.1.4.1.5003.9.10.12.1.2.22.1.9
Waiting for changeover acknowledgement. Access: Online. AC INI-Param: SS7_LKSETTIMERS_T2
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 500..2147483647  

acSS7LinkSetTimersT3 1.3.6.1.4.1.5003.9.10.12.1.2.22.1.10
Time controlled diversion-delay to avoid mis-sequencing on changeback. Access: Online. AC INI-Param: SS7_LKSETTIMERS_T3
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 500..2147483647  

acSS7LinkSetTimersT4 1.3.6.1.4.1.5003.9.10.12.1.2.22.1.11
Waiting for changeback acknowledgement (first attempt). Access: Online. AC INI-Param: SS7_LKSETTIMERS_T4
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 500..2147483647  

acSS7LinkSetTimersT5 1.3.6.1.4.1.5003.9.10.12.1.2.22.1.12
Waiting for changeback acknowledgement (second attempt). Access: Online. AC INI-Param: SS7_LKSETTIMERS_T5
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 500..2147483647  

acSS7LinkSetTimersT7 1.3.6.1.4.1.5003.9.10.12.1.2.22.1.13
Waiting for signalling data link connection acknowledgement. Access: Online. AC INI-Param: SS7_LKSETTIMERS_T7
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 500..2147483647  

acSS7LinkSetTimersT12 1.3.6.1.4.1.5003.9.10.12.1.2.22.1.14
Waiting for uninhibit acknowledgement. Access: Online. AC INI-Param: SS7_LKSETTIMERS_T12
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 500..2147483647  

acSS7LinkSetTimersT13 1.3.6.1.4.1.5003.9.10.12.1.2.22.1.15
Waiting for force uninhibit. Access: Online. AC INI-Param: SS7_LKSETTIMERS_T13
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 500..2147483647  

acSS7LinkSetTimersT14 1.3.6.1.4.1.5003.9.10.12.1.2.22.1.16
Waiting for inhibition acknowledgement. Access: Online. AC INI-Param: SS7_LKSETTIMERS_T14
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 500..2147483647  

acSS7LinkSetTimersT17 1.3.6.1.4.1.5003.9.10.12.1.2.22.1.17
Delay to avoid oscillation of initial alignment failure and link restart. Access: Online. AC INI-Param: SS7_LKSETTIMERS_T17
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 500..2147483647  

acSS7LinkSetTimersT20ANSI 1.3.6.1.4.1.5003.9.10.12.1.2.22.1.18
Local inhibit test timer. Access: Online. AC INI-Param: SS7_LKSETTIMERS_T20_ANSI
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 500..2147483647  

acSS7LinkSetTimersT21ANSI 1.3.6.1.4.1.5003.9.10.12.1.2.22.1.19
Remote inhibit test timer. Access: Online. AC INI-Param: SS7_LKSETTIMERS_T21_ANSI
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 500..2147483647  

acSS7LinkSetTimersT22ITU 1.3.6.1.4.1.5003.9.10.12.1.2.22.1.20
Local inhibit test timer. Access: Online. AC INI-Param: SS7_LKSETTIMERS_T22_ITU
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 500..2147483647  

acSS7LinkSetTimersT23ITU 1.3.6.1.4.1.5003.9.10.12.1.2.22.1.21
Remote inhibit test timer. Access: Online. AC INI-Param: SS7_LKSETTIMERS_T23_ITU
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 500..2147483647  


acSS7LinkCommonTable 1.3.6.1.4.1.5003.9.10.12.1.3.21
Tok_String
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AcSS7LinkCommonEntry

acSS7LinkCommonEntry 1.3.6.1.4.1.5003.9.10.12.1.3.21.1
Tok_String
Status: current Access: not-accessible
OBJECT-TYPE    
  AcSS7LinkCommonEntry  

acSS7LinkCommonIndex 1.3.6.1.4.1.5003.9.10.12.1.3.21.1.1
Index Field for line. AC INI-Param: MAX_SIGNALING_LINKS_PER_CARD
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32 0..63  

acSS7LinkCommonRowStatus 1.3.6.1.4.1.5003.9.10.12.1.3.21.1.2
ROWSTATUS Field for line. AC INI-Param: SS7_LINK_ROWSTATUS
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

acSS7LinkCommonAction 1.3.6.1.4.1.5003.9.10.12.1.3.21.1.3
management Field for ACTIONS. AC INI-Param: SS7_LINK_ACTION
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER none(0), offLine(1), inService(2), activate(3), deActivate(4), inhibit(5), unInhibit(6), lpo(7), lpr(8)  

acSS7LinkCommonActionResult 1.3.6.1.4.1.5003.9.10.12.1.3.21.1.4
management Field for ACTIONS RESULT. AC INI-Param: SS7_LINK_ACTION_RESULT
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER succeeded(0), inProgress(1), failed(2)  

acSS7LinkCommonName 1.3.6.1.4.1.5003.9.10.12.1.3.21.1.5
String name for Link paramaters. Access: Online. AC INI-Param: SS7_LINK_NAME
Status: current Access: read-create
OBJECT-TYPE    
  SnmpAdminString Size(0..15)  

acSS7LinkCommonAdminState 1.3.6.1.4.1.5003.9.10.12.1.3.21.1.6
Administrative state of singnalling link. AC INI-Param: SS7_LINK_ADMINISTRATIVE_STATE
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER offLine(0), inService(2)  

acSS7LinkCommonOperState 1.3.6.1.4.1.5003.9.10.12.1.3.21.1.7
Operational state of singnalling link. AC INI-Param: SS7_LINK_OPERATIONAL_STATE
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER offLine(0), busy(1), inService(2)  

acSS7LinkCommonTraceLevel 1.3.6.1.4.1.5003.9.10.12.1.3.21.1.8
Trace level of singnalling link (level 2). Access: Online. AC INI-Param: SS7_LINK_TRACE_LEVEL
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER traceLevel0(0), traceLevel1(1)  

acSS7LinkCommonL2TypeSelector 1.3.6.1.4.1.5003.9.10.12.1.3.21.1.9
Link layer 2 type - defines level 2 media of signaling link. Access: Online. AC INI-Param: SS7_LINK_L2_TYPE
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER nonetype-L2(0), mtp2(1), m2ua-mgc(2), ss7monitoring(4)  

acSS7LinkCommonL3TypeSelector 1.3.6.1.4.1.5003.9.10.12.1.3.21.1.10
Link high layer type - defines level 3 or L2 high layer of signalling link. Access: Online. AC INI-Param: SS7_LINK_L3_TYPE
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER nonetype-L3(0), m2ua-sg(1), mtp3(2), mtp2-tunneling(3), mtp2OverIP(4), ss7monitoring(5)  

acSS7LinkCommonVariant 1.3.6.1.4.1.5003.9.10.12.1.3.21.1.11
Variant (layer 2) of singnalling link (TDM). Access: Online. AC INI-Param: SS7_LINK_LAYER2_VARIANT
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER itu(1), ansi(2), china(3)  

acSS7LinkCommonMtcBusy 1.3.6.1.4.1.5003.9.10.12.1.3.21.1.12
Link local busy indicator - if set, indicates link is busy due to local mtc action. AC INI-Param: SS7_LINK_MTC_BUSY
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER no(0), yes(1)  

acSS7LinkCommonRdcyBoardNum 1.3.6.1.4.1.5003.9.10.12.1.3.21.1.13
Board number in which the link is physically connected. Access: Online. AC INI-Param: SS7_LINK_RDCY_BOARD
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER rdcyBoardNum0(0), rdcyBoardNum1(1), rdcyBoardNum2(2)  

acSS7LinkCommonMonSuFilterRequest 1.3.6.1.4.1.5003.9.10.12.1.3.21.1.14
SS7 Monitoring link SU filter- Defines the type of SU message to filter. 0: Filter all types of SU messages 1: Filter LSSU and FISU messages 2: Filter only FISU messages 3: Do not filter any message. Access: Online. AC INI-Param: SS7_LINK_MON_SU_FILTER
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER filterAll(0), filterLSSUandFISU(1), filterFISU(2), noFilter(3)  

acSS7LinkTDMTable 1.3.6.1.4.1.5003.9.10.12.1.3.22
Tok_String
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AcSS7LinkTDMEntry

acSS7LinkTDMEntry 1.3.6.1.4.1.5003.9.10.12.1.3.22.1
Tok_String
Status: current Access: not-accessible
OBJECT-TYPE    
  AcSS7LinkTDMEntry  

acSS7LinkTDMTrunkNumber 1.3.6.1.4.1.5003.9.10.12.1.3.22.1.1
Trunk number of singnalling link (TDM). Access: Online. AC INI-Param: SS7_LINK_TRUNK_NUMBER
Status: current Access: read-create
OBJECT-TYPE    
  Integer32 -1..84  

acSS7LinkTDMTimeSlotNumber 1.3.6.1.4.1.5003.9.10.12.1.3.22.1.2
Time-Slot number of singnalling link (TDM). Access: Online. AC INI-Param: SS7_LINK_TIMESLOT_NUMBER
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32 1..31  

acSS7LinkTDMInhibit 1.3.6.1.4.1.5003.9.10.12.1.3.22.1.3
Link inhibit indicator - if set, indicates link is inhibited.. AC INI-Param: SS7_LINK_INHIBITION
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER unInhibited(0), inhibited(1)  

acSS7LinkTDMMtp2Atts 1.3.6.1.4.1.5003.9.10.12.1.3.22.1.4
MTP2 attributes of singnalling link (TDM). Access: Online. AC INI-Param: SS7_LINK_MTP2_ATTRIBUTES
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER mtp2Atts0(0), mtp2Atts1(1), mtp2Atts2(2), mtp2Atts3(3)  

acSS7LinkTDMCongestionLowMark 1.3.6.1.4.1.5003.9.10.12.1.3.22.1.5
Link congestion low mark of signalling link (TDM). Access: Online. AC INI-Param: SS7_CONGESTION_LOW_MARK
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32 0..255  

acSS7LinkTDMCongestionHighMark 1.3.6.1.4.1.5003.9.10.12.1.3.22.1.6
Link congestion high mark of signalling link (TDM). Access: Online. AC INI-Param: SS7_CONGESTION_HIGH_MARK
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32 0..255  

acSS7LinkTDMBlock 1.3.6.1.4.1.5003.9.10.12.1.3.22.1.7
Link blocked indicator. AC INI-Param: SS7_LINK_BLOCKED
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER l3linkunblocked(0), l3linklocalblocked(1), l3linkremoteblockde(2), l3linklocalandremotelocked(3)  

acSS7LinkSigTranTable 1.3.6.1.4.1.5003.9.10.12.1.3.23
Tok_String
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AcSS7LinkSigTranEntry

acSS7LinkSigTranEntry 1.3.6.1.4.1.5003.9.10.12.1.3.23.1
Tok_String
Status: current Access: not-accessible
OBJECT-TYPE    
  AcSS7LinkSigTranEntry  

acSS7LinkSigTranGroupId 1.3.6.1.4.1.5003.9.10.12.1.3.23.1.1
Group ID (M2UA) of signaling link. Access: Online. AC INI-Param: SS7_LINK_GROUP_ID
Status: current Access: read-create
OBJECT-TYPE    
  Integer32 -1..65534  

acSS7LinkSigTranIfid 1.3.6.1.4.1.5003.9.10.12.1.3.23.1.2
Interface ID (M2UA) of singnalling link. Access: Online. AC INI-Param: SS7_LINK_M2UA_IF_ID
Status: current Access: read-create
OBJECT-TYPE    
  Integer32 -1..2147483647  

acSS7LinkATMTable 1.3.6.1.4.1.5003.9.10.12.1.3.24
Tok_String
Status: obsolete Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AcSS7LinkATMEntry

acSS7LinkATMEntry 1.3.6.1.4.1.5003.9.10.12.1.3.24.1
Tok_String
Status: obsolete Access: not-accessible
OBJECT-TYPE    
  AcSS7LinkATMEntry  

acSS7LinkATMSAALLinkProfileNum 1.3.6.1.4.1.5003.9.10.12.1.3.24.1.1
ATM SAAL Link profile number. Access: Online. AC INI-Param: ATM_SAAL_LINK_PROFILE_NUM
Status: obsolete Access: read-create
OBJECT-TYPE    
  Unsigned32 0..128  

acSS7LinkATMSAALLinkType 1.3.6.1.4.1.5003.9.10.12.1.3.24.1.2
ATM SAAL link Type PVC/SVC. Access: Online. AC INI-Param: ATM_SAAL_LINK_TYPE
Status: obsolete Access: read-create
OBJECT-TYPE    
  INTEGER aTM-VCC-Type-PVC(0), aTM-VCC-Type-SVC(1)  

acSS7LinkATMSAALLinkInterfaceNum 1.3.6.1.4.1.5003.9.10.12.1.3.24.1.3
ATM SAAL link port num. Access: Online. AC INI-Param: ATM_SAAL_LINK_PORT_NUM
Status: obsolete Access: read-create
OBJECT-TYPE    
  Unsigned32 0..128  

acSS7LinkATMSAALLinkVPI 1.3.6.1.4.1.5003.9.10.12.1.3.24.1.4
ATM SAAL link VPI. Access: Online. AC INI-Param: ATM_SAAL_LINK_VPI
Status: obsolete Access: read-create
OBJECT-TYPE    
  Unsigned32 0..255  

acSS7LinkATMSAALLinkVCI 1.3.6.1.4.1.5003.9.10.12.1.3.24.1.5
ATM SAAL link VCI. Access: Online. AC INI-Param: ATM_SAAL_LINK_VCI
Status: obsolete Access: read-create
OBJECT-TYPE    
  Unsigned32 0..65536  

acSS7LinkTNLTable 1.3.6.1.4.1.5003.9.10.12.1.3.25
Tok_String
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AcSS7LinkTNLEntry

acSS7LinkTNLEntry 1.3.6.1.4.1.5003.9.10.12.1.3.25.1
Tok_String
Status: current Access: not-accessible
OBJECT-TYPE    
  AcSS7LinkTNLEntry  

acSS7LinkTNLOtherSideLinkNum 1.3.6.1.4.1.5003.9.10.12.1.3.25.1.1
MTP2 Tunneling: MGC link number (MTP2 'other side' of signaling link). Access: Online. AC INI-Param: SS7_LINK_TNL_MGC_LINK_NUMBER
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32 0..128  

acSS7LinkTNLAlignmentMode 1.3.6.1.4.1.5003.9.10.12.1.3.25.1.2
MTP2 Tunneling: Alignment mode of signalling links in tunnel. Access: Online. AC INI-Param: SS7_LINK_TNL_ALIGNMENT_MODE
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER normal(0), emergency(1)  

acSS7LinkTNLCongestionMode 1.3.6.1.4.1.5003.9.10.12.1.3.25.1.3
MTP2 Tunneling: Congestion mode of signalling links in tunnel. Access: Online. AC INI-Param: SS7_LINK_TNL_CONGESTION_MODE
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER accept(0), discard(1)  

acSS7LinkTNLWaitStartCompTimer 1.3.6.1.4.1.5003.9.10.12.1.3.25.1.4
MTP2 Tunneling: wait start complete timer. Access: Online. AC INI-Param: SS7_LINK_TNL_WAIT_START_COMPLETE_TIMER
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32 0..2147483647  

acSS7LinkTNLOosStartDelayTimer 1.3.6.1.4.1.5003.9.10.12.1.3.25.1.5
MTP2 Tunneling: OOS start delay timer. Access: Online. AC INI-Param: SS7_LINK_TNL_OOS_START_DELAY_TIMER
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32 0..2147483647  

acSS7LinkTNLWaitOtherSideInsvTimer 1.3.6.1.4.1.5003.9.10.12.1.3.25.1.6
MTP2 Tunneling: wait for other side to be in service timer. Access: Online. AC INI-Param: SS7_LINK_TNL_WAIT_OTHER_SIDE_INSV_TIMER
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32 0..2147483647  

acSS7Nodes 1.3.6.1.4.1.5003.9.10.12.1.4
OBJECT IDENTIFIER    

acSS7SignalingNodeTable 1.3.6.1.4.1.5003.9.10.12.1.4.21
Tok_String
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AcSS7SignalingNodeEntry

acSS7SignalingNodeEntry 1.3.6.1.4.1.5003.9.10.12.1.4.21.1
Tok_String
Status: current Access: not-accessible
OBJECT-TYPE    
  AcSS7SignalingNodeEntry  

acSS7SignalingNodeIndex 1.3.6.1.4.1.5003.9.10.12.1.4.21.1.1
AC INI-Param: SS7_SN_INDEX
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32 0..1  

acSS7SignalingNodeRowStatus 1.3.6.1.4.1.5003.9.10.12.1.4.21.1.2
ROWSTATUS Field for line. AC INI-Param: SS7_SN_ROWSTATUS
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

acSS7SignalingNodeAction 1.3.6.1.4.1.5003.9.10.12.1.4.21.1.3
management Field for ACTIONS. AC INI-Param: SS7_SN_ACTION
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER none(0), stop(1), start(2), inService(3), offLine(4)  

acSS7SignalingNodeActionResult 1.3.6.1.4.1.5003.9.10.12.1.4.21.1.4
management Field for ACTIONS RESULT. AC INI-Param: SS7_SN_ACTION_RESULT
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER succeeded(0), inProgress(1), failed(2)  

acSS7SignalingNodeName 1.3.6.1.4.1.5003.9.10.12.1.4.21.1.5
String name for SN Params. Access: Online. AC INI-Param: SS7_SN_NAME
Status: current Access: read-create
OBJECT-TYPE    
  SnmpAdminString Size(0..15)  

acSS7SignalingNodeTraceLevel 1.3.6.1.4.1.5003.9.10.12.1.4.21.1.6
Trace level of singnalling node (level 3). Access: Online. AC INI-Param: SS7_SN_TRACE_LEVEL
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER traceLevel0(0), traceLevel1(1)  

acSS7SignalingNodeAdminState 1.3.6.1.4.1.5003.9.10.12.1.4.21.1.7
Administrative state of singnalling node. AC INI-Param: SS7_SN_ADMINISTRATIVE_STATE
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER offLine(0), inService(2)  

acSS7SignalingNodeOperState 1.3.6.1.4.1.5003.9.10.12.1.4.21.1.8
Operational state of singnalling node. AC INI-Param: SS7_SN_OPERATIONAL_STATE
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER offLine(0), busy(1), inService(2)  

acSS7SignalingNodeMtcBusy 1.3.6.1.4.1.5003.9.10.12.1.4.21.1.9
Manual busy status of singnalling node. AC INI-Param: SS7_SN_MTC_BUSY_STATUS
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER no(0), yes(1)  

acSS7SignalingNodeVariant 1.3.6.1.4.1.5003.9.10.12.1.4.21.1.10
Variant of singnalling node. Access: Online. AC INI-Param: SS7_SN_VARIANT
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER itu(1), ansi(2), china(3)  

acSS7SignalingNodeNwIndicator 1.3.6.1.4.1.5003.9.10.12.1.4.21.1.11
Network Indicator of singnalling node. Access: Online. AC INI-Param: SS7_SN_NI
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER international(0), internationalSpare(1), national(2), nationalSpare(3)  

acSS7SignalingNodeSpStp 1.3.6.1.4.1.5003.9.10.12.1.4.21.1.12
Routing function of singnalling node. Access: Online. AC INI-Param: SS7_SN_SP_STP
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER sp(0), stp(1)  

acSS7SignalingNodeTfc 1.3.6.1.4.1.5003.9.10.12.1.4.21.1.13
TFC function of singnalling node. Access: Online. AC INI-Param: SS7_SN_TFC
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER no(0), yes(1)  

acSS7SignalingNodeOpc 1.3.6.1.4.1.5003.9.10.12.1.4.21.1.14
Origination (local) point-code of singnalling node. Access: Online. AC INI-Param: SS7_SN_OPC
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32 0..2147483647  

acSS7SignalingNodeRouteSetCongestionWindow 1.3.6.1.4.1.5003.9.10.12.1.4.21.1.15
Routeset Congestion Size (messages) of singnalling node. Access: Online. AC INI-Param: SS7_SN_ROUTESET_CONGESTION_WINSIZE
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32 0..255  

acSS7SignalingNodeTimersIdx 1.3.6.1.4.1.5003.9.10.12.1.4.21.1.16
Index of SNTimers table used for this signaling node. Access: Online. AC INI-Param: SS7_SN_TIMERS_INDEX
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER timersIdx0(0), timersIdx1(1), timersIdx2(2), timersIdx3(3), timersIdx4(4)  

acSS7SignalingNodeIsupApp 1.3.6.1.4.1.5003.9.10.12.1.4.21.1.17
Level 4 application that handles ISUP traffic for this singnalling node. Access: Online. AC INI-Param: SS7_SN_ISUP_APP
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER nill(0), ual(4), l4Gen(7)  

acSS7SignalingNodeSccpApp 1.3.6.1.4.1.5003.9.10.12.1.4.21.1.18
Level 4 application that handles SCCP traffic for this singnalling node. Access: Online. AC INI-Param: SS7_SN_SCCP_APP
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER nill(0), ual(4), l4Gen(7)  

acSS7SignalingNodeBisupApp 1.3.6.1.4.1.5003.9.10.12.1.4.21.1.19
Level 4 application that handles BISUP traffic for this singnalling node. Access: Online. AC INI-Param: SS7_SN_BISUP_APP
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER nill(0), ual(4), l4Gen(7)  

acSS7SignalingNodeAlcapApp 1.3.6.1.4.1.5003.9.10.12.1.4.21.1.20
Level 4 application that handles ALCAP traffic for this singnalling node. Access: Online. AC INI-Param: SS7_SN_ALCAP_APP
Status: deprecated Access: read-create
OBJECT-TYPE    
  INTEGER nill(0), ual(4), alcap(5), l4Gen(7)  

acSS7SignalingNodeRdcyOpc 1.3.6.1.4.1.5003.9.10.12.1.4.21.1.21
Internal point-code of singnalling node - in case of SS7 shared point code. AC INI-Param: SS7_SN_RDCY_OPC
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32 0..2147483647  

acSS7SignalingNodeTupApp 1.3.6.1.4.1.5003.9.10.12.1.4.21.1.22
Level 4 application that handles TUP traffic for this signaling node. Access: Online. AC INI-Param: SS7_SN_TUP_APP
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER nill(0), ual(4), l4Gen(7)  

acSS7SignalingNodeBiccApp 1.3.6.1.4.1.5003.9.10.12.1.4.21.1.23
Level 4 application that handles BICC traffic for this signaling node. Access: Online. AC INI-Param: SS7_SN_BICC_APP
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER nil(0), ual(4)  

acSS7LinkSets 1.3.6.1.4.1.5003.9.10.12.1.4.31
OBJECT IDENTIFIER    

acSS7LinkSetTable 1.3.6.1.4.1.5003.9.10.12.1.4.31.21
Tok_String
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AcSS7LinkSetEntry

acSS7LinkSetEntry 1.3.6.1.4.1.5003.9.10.12.1.4.31.21.1
Tok_String
Status: current Access: not-accessible
OBJECT-TYPE    
  AcSS7LinkSetEntry  

acSS7LinkSetSNIndex 1.3.6.1.4.1.5003.9.10.12.1.4.31.21.1.1
First Index Field for line. AC INI-Param: SS7_LINKSET_SN_INDEX
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32 0..1  

acSS7LinkSetLksetIndex 1.3.6.1.4.1.5003.9.10.12.1.4.31.21.1.2
Second Index Field for line. AC INI-Param: SS7_LINKSET_LINKSET_INDEX
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32 0..31  

acSS7LinkSetRowStatus 1.3.6.1.4.1.5003.9.10.12.1.4.31.21.1.3
ROWSTATUS Field for line. AC INI-Param: SS7_LINKSET_ROWSTATUS
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

acSS7LinkSetAction 1.3.6.1.4.1.5003.9.10.12.1.4.31.21.1.4
management Field for ACTIONS. AC INI-Param: SS7_LINKSET_ACTION
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER none(0), offLine(1), inService(2), activate(3), deActivate(4)  

acSS7LinkSetActionResult 1.3.6.1.4.1.5003.9.10.12.1.4.31.21.1.5
management Field for ACTIONS RESULT. AC INI-Param: SS7_SN_ACTION_RESULT
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER succeeded(0), inProgress(1), failed(2)  

acSS7LinkSetName 1.3.6.1.4.1.5003.9.10.12.1.4.31.21.1.6
String name for LINKSET Params. Access: Online. AC INI-Param: SS7_LINKSET_NAME
Status: current Access: read-create
OBJECT-TYPE    
  SnmpAdminString Size(0..15)  

acSS7LinkSetAdminState 1.3.6.1.4.1.5003.9.10.12.1.4.31.21.1.7
Administrative state of singnalling linkset. AC INI-Param: SS7_LINKSET_ADMINISTRATIVE_STATE
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER offLine(0), inService(2)  

acSS7LinkSetOperState 1.3.6.1.4.1.5003.9.10.12.1.4.31.21.1.8
Operational state of singnalling linkset. AC INI-Param: SS7_LINKSET_OPERATIONAL_STATE
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER offLine(0), busy(1), inService(2)  

acSS7LinkSetMtcBusyState 1.3.6.1.4.1.5003.9.10.12.1.4.31.21.1.9
Manual busy status of singnalling linkset. AC INI-Param: SS7_LINKSET_MTC_BUSY_STATUS
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER no(0), yes(1)  

acSS7LinkSetDPC 1.3.6.1.4.1.5003.9.10.12.1.4.31.21.1.10
Destination Point-Code of singnalling linkset. Access: Online. AC INI-Param: SS7_LINKSET_DPC
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32 0..2147483647  

acSS7LinkSetLinksMask 1.3.6.1.4.1.5003.9.10.12.1.4.31.21.1.11
Mask for links within singnalling linkset. Access: Online. AC INI-Param: SS7_LINKSET_MASK
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32 0..255  

acSS7LinkSetLinksAltMask 1.3.6.1.4.1.5003.9.10.12.1.4.31.21.1.12
Alternate mask for links within singnalling linkset. Access: Online. AC INI-Param: SS7_LINKSET_ALTERNATE_MASK
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32 0..255  

acSS7LinkSetTimersIdx 1.3.6.1.4.1.5003.9.10.12.1.4.31.21.1.13
Timers Index of singnalling linkset. Access: Online. AC INI-Param: SS7_LINKSET_TIMERS_INDEX
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER timersIdx0(0), timersIdx1(1), timersIdx2(2), timersIdx3(3), timersIdx4(4)  

acSS7LinkSetLinkTable 1.3.6.1.4.1.5003.9.10.12.1.4.31.22
Tok_String
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AcSS7LinkSetLinkEntry

acSS7LinkSetLinkEntry 1.3.6.1.4.1.5003.9.10.12.1.4.31.22.1
Tok_String
Status: current Access: not-accessible
OBJECT-TYPE    
  AcSS7LinkSetLinkEntry  

acSS7LinkSetLinkSNIndex 1.3.6.1.4.1.5003.9.10.12.1.4.31.22.1.1
First Index Field for line: Signalling Node Number. AC INI-Param: SS7_LINKSETLINK_SN_INDEX
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32 0..1  

acSS7LinkSetLinkLinksetIndex 1.3.6.1.4.1.5003.9.10.12.1.4.31.22.1.2
Second Index Field for line: Signalling Linkset Number. AC INI-Param: SS7_LINKSETLINK_LINKSET_INDEX
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32 0..31  

acSS7LinkSetLinkInnerLinkIndex 1.3.6.1.4.1.5003.9.10.12.1.4.31.22.1.3
Third Index Field for line: Inner Link Index in Signalling Linkset. AC INI-Param: SS7_LINKSETLINK_INNER_LINK_INDEX
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32 0..7  

acSS7LinkSetLinkRowStatus 1.3.6.1.4.1.5003.9.10.12.1.4.31.22.1.4
ROWSTATUS Field for line. AC INI-Param: SS7_LINKSETLINK_ROWSTATUS
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

acSS7LinkSetLinkAction 1.3.6.1.4.1.5003.9.10.12.1.4.31.22.1.5
management Field for ACTIONS. AC INI-Param: SS7_LINKSETLINK_ACTION
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER none(0)  

acSS7LinkSetLinkActionResult 1.3.6.1.4.1.5003.9.10.12.1.4.31.22.1.6
Management field for ACTIONS RESULT. AC INI-Param: SS7_LINKSETLINK_ACTION_RESULT
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER succeeded(0), inProgress(1), failed(2)  

acSS7LinkSetLinkLinkNo 1.3.6.1.4.1.5003.9.10.12.1.4.31.22.1.7
Physical number of signalling link which is part of the Linkset. Access: Online. AC INI-Param: SS7_LINKSETLINK_LINK_NUMBER
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32 0..128  

acSS7LinkSetLinkLinkSlc 1.3.6.1.4.1.5003.9.10.12.1.4.31.22.1.8
SLC number of signaling link which is part of the Linkset. Access: Online. AC INI-Param: SS7_LINKSETLINK_LINK_SLC
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32 0..15  

acSS7RouteSets 1.3.6.1.4.1.5003.9.10.12.1.4.32
OBJECT IDENTIFIER    

acSS7RouteSetTable 1.3.6.1.4.1.5003.9.10.12.1.4.32.21
Tok_String
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AcSS7RouteSetEntry

acSS7RouteSetEntry 1.3.6.1.4.1.5003.9.10.12.1.4.32.21.1
Tok_String
Status: current Access: not-accessible
OBJECT-TYPE    
  AcSS7RouteSetEntry  

acSS7RouteSetSNIndex 1.3.6.1.4.1.5003.9.10.12.1.4.32.21.1.1
First Index Field for line: Signalling Node Number. AC INI-Param: SS7_ROUTESET_SN_INDEX
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32 0..1  

acSS7RouteSetIndex 1.3.6.1.4.1.5003.9.10.12.1.4.32.21.1.2
Second Index Field for line: Signalling Routeset Number. AC INI-Param: SS7_ROUTESET_INDEX
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32 0..29  

acSS7RouteSetRowStatus 1.3.6.1.4.1.5003.9.10.12.1.4.32.21.1.3
ROWSTATUS Field for line. AC INI-Param: SS7_ROUTESET_ROWSTATUS
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

acSS7RouteSetAction 1.3.6.1.4.1.5003.9.10.12.1.4.32.21.1.4
management Field for ACTIONS. AC INI-Param: SS7_ROUTESET_ACTION
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER none(0), offLine(1), inService(2)  

acSS7RouteSetActionResult 1.3.6.1.4.1.5003.9.10.12.1.4.32.21.1.5
management Field for ACTIONS RESULT. AC INI-Param: SS7_ROUTESET_ACTION_RESULT
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER succeeded(0), inProgress(1), failed(2)  

acSS7RouteSetName 1.3.6.1.4.1.5003.9.10.12.1.4.32.21.1.6
String name for ROUTESET Params. Access: Online. AC INI-Param: SS7_ROUTESET_NAME
Status: current Access: read-create
OBJECT-TYPE    
  SnmpAdminString Size(0..15)  

acSS7RouteSetAdminState 1.3.6.1.4.1.5003.9.10.12.1.4.32.21.1.7
Administrative state of signalling route set. AC INI-Param: SS7_ROUTESET_ADMINISTRATIVE_STATE
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER offLine(0), inService(2)  

acSS7RouteSetOperState 1.3.6.1.4.1.5003.9.10.12.1.4.32.21.1.8
Operational state of signalling route set. AC INI-Param: SS7_ROUTESET_OPERATIONAL_STATE
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER offLine(0), busy(1), inService(2)  

acSS7RouteSetDPC 1.3.6.1.4.1.5003.9.10.12.1.4.32.21.1.9
Destination Point-Code of singnalling routesetset. Access: Online. AC INI-Param: SS7_ROUTESET_DPC
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32 0..2147483647  

acSS7RouteSetRouteMask 1.3.6.1.4.1.5003.9.10.12.1.4.32.21.1.10
Mask for route within signaling routeset. Access: Online. AC INI-Param: SS7_ROUTESET_MASK
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32 0..255  

acSS7RouteSetRouteTable 1.3.6.1.4.1.5003.9.10.12.1.4.32.22
Tok_String
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AcSS7RouteSetRouteEntry

acSS7RouteSetRouteEntry 1.3.6.1.4.1.5003.9.10.12.1.4.32.22.1
Tok_String
Status: current Access: not-accessible
OBJECT-TYPE    
  AcSS7RouteSetRouteEntry  

acSS7RouteSetRouteSNIndex 1.3.6.1.4.1.5003.9.10.12.1.4.32.22.1.1
First Index Field for line: Signalling Node Number. AC INI-Param: SS7_ROUTESETROUTE_SN_INDEX
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32 0..1  

acSS7RouteSetRouteRoutesetIndex 1.3.6.1.4.1.5003.9.10.12.1.4.32.22.1.2
Second Index Field for line: Signalling Routeset Number. AC INI-Param: SS7_ROUTESETROUTE_ROUTESET_INDEX
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32 0..29  

acSS7RouteSetRouteInnerRouteIndex 1.3.6.1.4.1.5003.9.10.12.1.4.32.22.1.3
Third Index Field for line: Inner Route Index in Signalling Routeset. AC INI-Param: SS7_ROUTESETROUTE_INNER_ROUTE_INDEX
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32 0..3  

acSS7RouteSetRouteRowStatus 1.3.6.1.4.1.5003.9.10.12.1.4.32.22.1.4
ROWSTATUS Field for line. AC INI-Param: SS7_ROUTESETROUTE_ROWSTATUS
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

acSS7RouteSetRouteAction 1.3.6.1.4.1.5003.9.10.12.1.4.32.22.1.5
management Field for ACTIONS. AC INI-Param: SS7_ROUTESETROUTE_ACTION
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER none(0)  

acSS7RouteSetRouteActionResult 1.3.6.1.4.1.5003.9.10.12.1.4.32.22.1.6
management Field for ACTIONS RESULT. AC INI-Param: SS7_ROUTESETROUTE_ACTION_RESULT
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER succeeded(0), inProgress(1), failed(2)  

acSS7RouteSetRouteLinkSetNo 1.3.6.1.4.1.5003.9.10.12.1.4.32.22.1.7
Number of signalling linkset which is part of the Routeset. Access: Online. AC INI-Param: SS7_ROUTESETROUTE_LINKSET_NUMBER
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32 0..128  

acSS7RouteSetRoutePriority 1.3.6.1.4.1.5003.9.10.12.1.4.32.22.1.8
Priority of route within routeset. Access: Online. AC INI-Param: SS7_ROUTESETROUTE_PRIORITY
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32 0..254  

acSS7AliasPointCode 1.3.6.1.4.1.5003.9.10.12.1.4.33
OBJECT IDENTIFIER    

acSS7APCTable 1.3.6.1.4.1.5003.9.10.12.1.4.33.21
Tok_String
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AcSS7APCEntry

acSS7APCEntry 1.3.6.1.4.1.5003.9.10.12.1.4.33.21.1
Tok_String
Status: current Access: not-accessible
OBJECT-TYPE    
  AcSS7APCEntry  

acSS7APCSNIndex 1.3.6.1.4.1.5003.9.10.12.1.4.33.21.1.1
First Index Field for line: Signaling Node Number. AC INI-Param: SS7_APC_SN_INDEX
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32 0..1  

acSS7APCIndex 1.3.6.1.4.1.5003.9.10.12.1.4.33.21.1.2
Second Index Field for line: Alias PC index. AC INI-Param: SS7_APC_INNER_INDEX
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32 0..1  

acSS7APCRowStatus 1.3.6.1.4.1.5003.9.10.12.1.4.33.21.1.3
ROWSTATUS Field for line. AC INI-Param: SS7_APC_ROWSTATUS
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

acSS7APCAction 1.3.6.1.4.1.5003.9.10.12.1.4.33.21.1.4
Management field for ACTIONS. AC INI-Param: SS7_APC_ACTION
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER none(0), offLine(1), inService(2), activate(3), deActivate(4)  

acSS7APCActionResult 1.3.6.1.4.1.5003.9.10.12.1.4.33.21.1.5
management Field for ACTIONS RESULT. AC INI-Param: SS7_APC_ACTION_RESULT
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER succeeded(0), inProgress(1), failed(2)  

acSS7APCPC 1.3.6.1.4.1.5003.9.10.12.1.4.33.21.1.6
Alias Point-Code of signaling node. Access: Online. AC INI-Param: SS7_APC_PC
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32 0..2147483647  

acSS7APCSNI 1.3.6.1.4.1.5003.9.10.12.1.4.33.21.1.7
SNI (Signaling Network Indicator) of Alias Point-Code. Access: Online. AC INI-Param: SS7_APC_SNI
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32 2..5  

acSS7APCName 1.3.6.1.4.1.5003.9.10.12.1.4.33.21.1.8
String name for Alias PC parameters. Access: Online. AC INI-Param: SS7_ALIAS_PC_NAME
Status: current Access: read-create
OBJECT-TYPE    
  SnmpAdminString Size(0..15)  

acSS7APCMtcBusy 1.3.6.1.4.1.5003.9.10.12.1.4.33.21.1.9
Manual busy status of Alias PC. AC INI-Param: SS7_ALIAS_PC_MTC_BUSY
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER no(0), yes(1)  

acSS7APCAdminState 1.3.6.1.4.1.5003.9.10.12.1.4.33.21.1.10
Administrative state of Alias PC. AC INI-Param: SS7_ALIAS_PC_ADMINISTRATIVE_STATE
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER offLine(0), busy(1), inService(2)  

acSS7APCOperState 1.3.6.1.4.1.5003.9.10.12.1.4.33.21.1.11
Operational state of Alias PC. AC INI-Param: SS7_ALIAS_PC_OPERATIONAL_STATE
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER offLine(0), busy(1), inService(2)  

acSS7SigTran 1.3.6.1.4.1.5003.9.10.12.1.5
OBJECT IDENTIFIER    

acSS7SigTranM3UATrafficBehavior 1.3.6.1.4.1.5003.9.10.12.1.5.1
Defines the M3UA behavior when the SS7 links are up, but there is no association to the soft switch. 0 = NONE (no special behavior) 1 = DEACTIVATE (busy links) 2 = SIPO (LPO links). Access: Offline. AC INI-Param: SS7M3UATrafficBehavior
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER none(0), deactivate(1), sIPO(2)  

acSS7SigTranIFGroupTable 1.3.6.1.4.1.5003.9.10.12.1.5.21
Tok_String
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AcSS7SigTranIFGroupEntry

acSS7SigTranIFGroupEntry 1.3.6.1.4.1.5003.9.10.12.1.5.21.1
Tok_String
Status: current Access: not-accessible
OBJECT-TYPE    
  AcSS7SigTranIFGroupEntry  

acSS7SigTranIFGroupIndex 1.3.6.1.4.1.5003.9.10.12.1.5.21.1.1
Index field for line. AC INI-Param: SS7_SIG_IF_GR_INDEX
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32 0..15  

acSS7SigTranIFGroupRowStatus 1.3.6.1.4.1.5003.9.10.12.1.5.21.1.2
ROWSTATUS field for line. AC INI-Param: SS7_SIG_IF_GR_ROWSTATUS
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

acSS7SigTranIFGroupAction 1.3.6.1.4.1.5003.9.10.12.1.5.21.1.3
Management field for ACTION. AC INI-Param: SS7_SIG_IF_GR_ACTION
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER none(0), activate(1), deActivate(2)  

acSS7SigTranIFGroupActionResult 1.3.6.1.4.1.5003.9.10.12.1.5.21.1.4
Management field for ACTION RESULT. AC INI-Param: SS7_SIG_IF_GR_ACTION_RESULT
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32 0..2147483647  

acSS7SigTranIFGroupId 1.3.6.1.4.1.5003.9.10.12.1.5.21.1.5
SS7 (Signaling System 7) SIGTRAN (Signaling Transport) Interface Group Id. Access: Online. AC INI-Param: SS7_IF_GR_ID
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32 0..65534  

acSS7SigTranIFGroupSgMgc 1.3.6.1.4.1.5003.9.10.12.1.5.21.1.6
Interface Group function - Signaling Gateway (SG) or Media Gateway Controller (MGC). Access: Online. AC INI-Param: SS7_SIG_SG_MGC
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER nat(1), mgc(77), sg(83)  

acSS7SigTranIFGroupSignalingLayer 1.3.6.1.4.1.5003.9.10.12.1.5.21.1.7
UAL type of interface group: 0 = none 1 = iua 2 = m2ua 3 = m3ua 4 = m2tunnel 5 = V5ua 6 = dua 7=isdnTunnel. Access: Online. AC INI-Param: SS7_SIG_LAYER
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER noLayer(0), iua(1), m2ua(2), m3ua(3), m2tunnel(4), dua(6), isdnTunnel(7)  

acSS7SigTranIFGroupTrafMode 1.3.6.1.4.1.5003.9.10.12.1.5.21.1.8
Traffic mode of interface group. Access: Online. AC INI-Param: SS7_SIG_TRAF_MODE
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER override(1), loadShare(2), broadcast(3)  

acSS7SigTranIFGroupRecovTimer 1.3.6.1.4.1.5003.9.10.12.1.5.21.1.9
T(r) - recovery timer (in msecs) of interface group. Access: Online. AC INI-Param: SS7_SIG_T_REC
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32 0..10000000  

acSS7SigTranIFGroupAckTimer 1.3.6.1.4.1.5003.9.10.12.1.5.21.1.10
T(ack) - wait timer for ASP_UP_ACK (in msecs) of interface group. Access: Online. AC INI-Param: SS7_SIG_T_ACK
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32 0..10000000  

acSS7SigTranIFGroupHBTimer 1.3.6.1.4.1.5003.9.10.12.1.5.21.1.11
T(beat) - Heartbeat Timer (in msecs) of interface group. Access: Online. AC INI-Param: SS7_SIG_T_HB
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32 0..10000000  

acSS7SigTranIFGroupMinAsp 1.3.6.1.4.1.5003.9.10.12.1.5.21.1.12
Minimal ASP (Application Server Process) number in interface group(minimum = 1). Access: Online. AC INI-Param: SS7_SIG_MIN_ASP
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32 1..10  

acSS7SigTranIFGroupBehavior 1.3.6.1.4.1.5003.9.10.12.1.5.21.1.13
Behavior bit of interface group. Access: Online. AC INI-Param: SS7_SIG_BEHAVIOUR
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32 0..2147483647  

acSS7SigTranIFGroupSCTPInst 1.3.6.1.4.1.5003.9.10.12.1.5.21.1.14
SCTP (Stream Control Transmission Protocol) instance of interface group. AC INI-Param: SS7_SCTP_INSTANCE
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32 0..65534  

acSS7SigTranIFGroupSCTPLocalPort 1.3.6.1.4.1.5003.9.10.12.1.5.21.1.15
Local SCTP (Stream Control Transmission Protocol) port of interface group. Access: Online. AC INI-Param: SS7_LOCAL_SCTP_PORT
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32 0..2147483647  

acSS7SigTranIFGroupNetwork 1.3.6.1.4.1.5003.9.10.12.1.5.21.1.16
Network variant of interface group. Access: Online. AC INI-Param: SS7_SIG_NETWORK
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER itu(1), ansi(2), china(3)  

acSS7SigTranIFGroupSCTPDestPort 1.3.6.1.4.1.5003.9.10.12.1.5.21.1.17
Destination SCTP (Stream Control Transmission Protocol) port. Access: Online. AC INI-Param: SS7_DEST_SCTP_PORT
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32 0..65534  

acSS7SigTranIFGroupDestIp 1.3.6.1.4.1.5003.9.10.12.1.5.21.1.18
Destination SCTP (Stream Control Transmission Protocol) IP address. Access: Online. AC INI-Param: SS7_DEST_IP
Status: current Access: read-create
OBJECT-TYPE    
  IpAddress  

acSS7SigTranIFGroupSCTPMaxInbStreams 1.3.6.1.4.1.5003.9.10.12.1.5.21.1.19
Maximum inbound streams in interface group. Access: Online. AC INI-Param: SS7_MGC_MX_IN_STREAM
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32 2..65534  

acSS7SigTranIFGroupSCTPMaxOutbStreams 1.3.6.1.4.1.5003.9.10.12.1.5.21.1.20
Number of output streams required in interface group. Access: Online. AC INI-Param: SS7_MGC_NUM_OUT_STREAM
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32 2..65534  

acSS7SigTranIFGroupRdcyBoardNum 1.3.6.1.4.1.5003.9.10.12.1.5.21.1.21
This parameter is used to specify the SIGTRAN (Signaling Transport) group redundancy board number. Access: Online. AC INI-Param: RdcyBoardNum
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32 0..255  

acSS7SigTranIFGroupRoutingContextIndex 1.3.6.1.4.1.5003.9.10.12.1.5.21.1.22
Entry in Routing Context table, that contains the routing context rules for this interface group. Access: Online. AC INI-Param: SS7_SIG_RC_INDEX
Status: current Access: read-create
OBJECT-TYPE    
  Integer32 -1..15  

acSS7SigTranIFGroupRoutingContextValue 1.3.6.1.4.1.5003.9.10.12.1.5.21.1.23
Routing context value for this interface group (AS). Access: Online. AC INI-Param: SS7_SIG_RC_VALUE
Status: current Access: read-create
OBJECT-TYPE    
  Integer32 -1..2147483647  

acSS7SigTranIFGroupNetworkAppearance 1.3.6.1.4.1.5003.9.10.12.1.5.21.1.24
Network Appearance value for this interface group (AS). Access: Online. AC INI-Param: SS7_SIG_NETWORK_APPEARANCE
Status: current Access: read-create
OBJECT-TYPE    
  Integer32 -1..2147483647  

acSS7SigTranIFIDTable 1.3.6.1.4.1.5003.9.10.12.1.5.22
Tok_String
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AcSS7SigTranIFIDEntry

acSS7SigTranIFIDEntry 1.3.6.1.4.1.5003.9.10.12.1.5.22.1
Tok_String
Status: current Access: not-accessible
OBJECT-TYPE    
  AcSS7SigTranIFIDEntry  

acSS7SigTranIFIDIndex 1.3.6.1.4.1.5003.9.10.12.1.5.22.1.1
Index field for line. AC INI-Param: SS7_SIG_IF_ID_INDEX
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32 0..83  

acSS7SigTranIFIDRowStatus 1.3.6.1.4.1.5003.9.10.12.1.5.22.1.2
ROWSTATUS field for line. AC INI-Param: SS7_SIG_IF_ID_ROWSTATUS
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

acSS7SigTranIFIDAction 1.3.6.1.4.1.5003.9.10.12.1.5.22.1.3
Management field for ACTION. AC INI-Param: SS7_SIG_IF_ID_ACTION
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER none(0), activate(1), deActivate(2)  

acSS7SigTranIFIDActionResult 1.3.6.1.4.1.5003.9.10.12.1.5.22.1.4
Management field for ACTION RESULT. AC INI-Param: SS7_SIG_IF_ID_ACTION_RESULT
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32 0..2147483647  

acSS7SigTranIFIDValue 1.3.6.1.4.1.5003.9.10.12.1.5.22.1.5
SS7 (Signaling System 7) SIGTRAN (Signaling Transport) interface ID value. Access: Online. AC INI-Param: SS7_SIG_IF_ID_VALUE
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32 0..2147483647  

acSS7SigTranIFIDName 1.3.6.1.4.1.5003.9.10.12.1.5.22.1.6
SS7 (Signaling System 7) SIGTRAN (Signaling Transport) interface ID name (text string). Access: Online. AC INI-Param: SS7_SIG_IF_ID_NAME
Status: current Access: read-create
OBJECT-TYPE    
  SnmpAdminString Size(0..15)  

acSS7SigTranIFIDOwnerGroup 1.3.6.1.4.1.5003.9.10.12.1.5.22.1.7
Owner group of interface id. Access: Online. AC INI-Param: SS7_SIG_IF_ID_OWNER_GROUP
Status: current Access: read-create
OBJECT-TYPE    
  Integer32 -1..65534  

acSS7SigTranIFIDSignalingLayer 1.3.6.1.4.1.5003.9.10.12.1.5.22.1.8
UAL Type of interface id: 0 = none 1 = iua 2 = m2ua 4 = m2tunnel 5 = V5ua 6 = dua 7=isdnTunnel. Access: Online. AC INI-Param: SS7_SIG_IF_ID_LAYER
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER noLayer(0), iua(1), m2ua(2), m2tunnel(4), dua(6), isdnTunnel(7)  

acSS7SigTranIFIDNai 1.3.6.1.4.1.5003.9.10.12.1.5.22.1.9
NAI of interface id. Access: Online. AC INI-Param: SS7_SIG_IF_ID_NAI
Status: current Access: read-create
OBJECT-TYPE    
  Integer32 -2..124  

acSS7SigTranIFIDM3UASpc 1.3.6.1.4.1.5003.9.10.12.1.5.22.1.10
This parameter is used to specify the SIGTRAN (Signaling Transport) M3UA (M3UA - SS7 MTP3-User Adaptation Layer) SPC. Access: Online. AC INI-Param: SS7_SIG_M3UA_SPC
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32 0..2147483647  

acSS7M3UAStaticRoutingTable 1.3.6.1.4.1.5003.9.10.12.1.5.23
Tok_String
Status: obsolete Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AcSS7M3UAStaticRoutingEntry

acSS7M3UAStaticRoutingEntry 1.3.6.1.4.1.5003.9.10.12.1.5.23.1
Tok_String
Status: obsolete Access: not-accessible
OBJECT-TYPE    
  AcSS7M3UAStaticRoutingEntry  

acSS7M3UAStaticRoutingIndex 1.3.6.1.4.1.5003.9.10.12.1.5.23.1.1
This parameter is used for the Signaling System 7 (SS7) interface ID index, for a line. AC INI-Param: M3UAROUTINGCLIST_Index
Status: obsolete Access: not-accessible
OBJECT-TYPE    
  Unsigned32 0..100  

acSS7M3UAStaticRoutingRowStatus 1.3.6.1.4.1.5003.9.10.12.1.5.23.1.2
This parameter is used for the Signaling System 7 (SS7) interface ID row status, for a line. AC INI-Param: SS7_SIG_IF_ID_ROWSTATUS
Status: obsolete Access: read-create
OBJECT-TYPE    
  RowStatus  

acSS7M3UAStaticRoutingAction 1.3.6.1.4.1.5003.9.10.12.1.5.23.1.3
This parameter is used for Signaling System 7 (SS7) SIGTRAN (Signaling Transport) interface ID management, for actions. AC INI-Param: SS7_SIG_IF_ID_ACTION
Status: obsolete Access: read-create
OBJECT-TYPE    
  INTEGER none(0), activate(1), deActivate(2)  

acSS7M3UAStaticRoutingActionResult 1.3.6.1.4.1.5003.9.10.12.1.5.23.1.4
This parameter is used for Signaling System 7 (SS7) SIGTRAN (Signaling Transport) interface ID management, for an action's results. AC INI-Param: SS7_SIG_IF_ID_ACTION_RESULT
Status: obsolete Access: read-only
OBJECT-TYPE    
  Unsigned32 0..2147483647  

acSS7M3UAStaticRoutingOwnerInterfaceGroup 1.3.6.1.4.1.5003.9.10.12.1.5.23.1.5
Routing Context list - for M3UA use. Access: Online. AC INI-Param: M3UAROUTINGCLIST_OwnerInterfaceGroup
Status: obsolete Access: read-create
OBJECT-TYPE    
  Unsigned32 0..30  

acSS7M3UAStaticRoutingRC 1.3.6.1.4.1.5003.9.10.12.1.5.23.1.6
Routing Context list - for M3UA use. Access: Online. AC INI-Param: M3UAROUTINGCLIST_RoutingContext
Status: obsolete Access: read-create
OBJECT-TYPE    
  Unsigned32 0..16777215  

acSS7M3UAStaticRoutingDestinationPointCode 1.3.6.1.4.1.5003.9.10.12.1.5.23.1.7
Routing Context list - for M3UA use. Access: Online. AC INI-Param: M3UAROUTINGCLIST_DestinationPointCode
Status: obsolete Access: read-create
OBJECT-TYPE    
  Unsigned32 0..16777215  

acSS7M3UAStaticRoutingNetworkAppearence 1.3.6.1.4.1.5003.9.10.12.1.5.23.1.8
Routing Context list - for M3UA use. Access: Online. AC INI-Param: M3UAROUTINGCLIST_NetworkAppearence
Status: obsolete Access: read-create
OBJECT-TYPE    
  Unsigned32 0..16777215  

acSS7M3UAStaticRoutingSeriviceIndicatorList 1.3.6.1.4.1.5003.9.10.12.1.5.23.1.9
Routing Context list - for M3UA use. Access: Online. AC INI-Param: M3UAROUTINGCLIST_SeriviceIndicatorList
Status: obsolete Access: read-create
OBJECT-TYPE    
  Unsigned32 0..65535  

acSS7M3UAStaticRoutingOPC1 1.3.6.1.4.1.5003.9.10.12.1.5.23.1.10
Routing Context list - for M3UA use. Access: Online. AC INI-Param: M3UAROUTINGCLIST_OPC1
Status: obsolete Access: read-create
OBJECT-TYPE    
  Unsigned32 0..16777215  

acSS7M3UAStaticRoutingOPC2 1.3.6.1.4.1.5003.9.10.12.1.5.23.1.11
Routing Context list - for M3UA use. Access: Online. AC INI-Param: M3UAROUTINGCLIST_OPC2
Status: obsolete Access: read-create
OBJECT-TYPE    
  Unsigned32 0..16777215  

acSS7M3UAStaticRoutingOPC3 1.3.6.1.4.1.5003.9.10.12.1.5.23.1.12
Routing Context list - for M3UA use. Access: Online. AC INI-Param: M3UAROUTINGCLIST_OPC3
Status: obsolete Access: read-create
OBJECT-TYPE    
  Unsigned32 0..16777215  

acSS7M3UAStaticRoutingOPC4 1.3.6.1.4.1.5003.9.10.12.1.5.23.1.13
Routing Context list - for M3UA use. Access: Online. AC INI-Param: M3UAROUTINGCLIST_OPC4
Status: obsolete Access: read-create
OBJECT-TYPE    
  Unsigned32 0..16777215  

acSS7M3UAStaticRoutingLowerCICValue1 1.3.6.1.4.1.5003.9.10.12.1.5.23.1.14
Routing Context list - for M3UA use. Access: Online. AC INI-Param: M3UAROUTINGCLIST_LowerCICValue1
Status: obsolete Access: read-create
OBJECT-TYPE    
  Unsigned32 0..65535  

acSS7M3UAStaticRoutingUpperCICValue1 1.3.6.1.4.1.5003.9.10.12.1.5.23.1.15
Routing Context list - for M3UA use. Access: Online. AC INI-Param: M3UAROUTINGCLIST_UpperCICValue1
Status: obsolete Access: read-create
OBJECT-TYPE    
  Unsigned32 0..65535  

acSS7M3UAStaticRoutingLowerCICValue2 1.3.6.1.4.1.5003.9.10.12.1.5.23.1.16
Routing Context list - for M3UA use. Access: Online. AC INI-Param: M3UAROUTINGCLIST_LowerCICValue2
Status: obsolete Access: read-create
OBJECT-TYPE    
  Unsigned32 0..65535  

acSS7M3UAStaticRoutingUpperCICValue2 1.3.6.1.4.1.5003.9.10.12.1.5.23.1.17
Routing Context list - for M3UA use. Access: Online. AC INI-Param: M3UAROUTINGCLIST_UpperCICValue2
Status: obsolete Access: read-create
OBJECT-TYPE    
  Unsigned32 0..65535  

acSS7M3UAStaticRoutingLowerCICValue3 1.3.6.1.4.1.5003.9.10.12.1.5.23.1.18
Routing Context list - for M3UA use. Access: Online. AC INI-Param: M3UAROUTINGCLIST_LowerCICValue3
Status: obsolete Access: read-create
OBJECT-TYPE    
  Unsigned32 0..65535  

acSS7M3UAStaticRoutingUpperCICValue3 1.3.6.1.4.1.5003.9.10.12.1.5.23.1.19
Routing Context list - for M3UA use. Access: Online. AC INI-Param: M3UAROUTINGCLIST_UpperCICValue3
Status: obsolete Access: read-create
OBJECT-TYPE    
  Unsigned32 0..65535  

acSS7M3UAStaticRoutingLowerCICValue4 1.3.6.1.4.1.5003.9.10.12.1.5.23.1.20
Routing Context list - for M3UA use. Access: Online. AC INI-Param: M3UAROUTINGCLIST_LowerCICValue4
Status: obsolete Access: read-create
OBJECT-TYPE    
  Unsigned32 0..65535  

acSS7M3UAStaticRoutingUpperCICValue4 1.3.6.1.4.1.5003.9.10.12.1.5.23.1.21
Routing Context list - for M3UA use. Access: Online. AC INI-Param: M3UAROUTINGCLIST_UpperCICValue4
Status: obsolete Access: read-create
OBJECT-TYPE    
  Unsigned32 0..65535  

acSS7SigTranRoutingContextTable 1.3.6.1.4.1.5003.9.10.12.1.5.24
Tok_String
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AcSS7SigTranRoutingContextEntry

acSS7SigTranRoutingContextEntry 1.3.6.1.4.1.5003.9.10.12.1.5.24.1
Tok_String
Status: current Access: not-accessible
OBJECT-TYPE    
  AcSS7SigTranRoutingContextEntry  

acSS7SigTranRoutingContextIndex 1.3.6.1.4.1.5003.9.10.12.1.5.24.1.1
First index field for line. AC INI-Param: SS7_RC_INDEX
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32 0..31  

acSS7SigTranRoutingContextInnerIndex 1.3.6.1.4.1.5003.9.10.12.1.5.24.1.2
Second index field for line. AC INI-Param: SS7_RC_INNER_INDEX
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32 0..3  

acSS7SigTranRoutingContextRowStatus 1.3.6.1.4.1.5003.9.10.12.1.5.24.1.3
ROWSTATUS field for line. AC INI-Param: SS7_RC_ROW_STATUS
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

acSS7SigTranRoutingContextAction 1.3.6.1.4.1.5003.9.10.12.1.5.24.1.4
Management field for ACTIONS. AC INI-Param: RCAction
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER none(0), activate(1), deActivate(2)  

acSS7SigTranRoutingContextActionResult 1.3.6.1.4.1.5003.9.10.12.1.5.24.1.5
RCActionRes. AC INI-Param: SS7_RC_ACTION_RES
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32 0..2147483647  

acSS7SigTranRoutingContextSnIdx 1.3.6.1.4.1.5003.9.10.12.1.5.24.1.6
This parameter is used to specify the M3UA Routing Context DPC SN-Index. Access: Online. AC INI-Param: SS7_RC_SN_INDEX
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32 0..5  

acSS7SigTranRoutingContextSpc 1.3.6.1.4.1.5003.9.10.12.1.5.24.1.7
This parameter is used to specify the M3UA Routing Context DPC parameter. AC INI-Param: SS7_RC_SPC
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 -1..16777215  

acSS7SigTranRoutingContextOpc1 1.3.6.1.4.1.5003.9.10.12.1.5.24.1.8
This parameter is used to specify the M3UA Routing Context,First element of OPC list. Access: Online. AC INI-Param: SS7_RC_OPC1
Status: current Access: read-create
OBJECT-TYPE    
  Integer32 -1..16777215  

acSS7SigTranRoutingContextOpc2 1.3.6.1.4.1.5003.9.10.12.1.5.24.1.9
This parameter is used to specify the M3UA Routing Context,Second element of OPC list. Access: Online. AC INI-Param: SS7_RC_OPC2
Status: current Access: read-create
OBJECT-TYPE    
  Integer32 -1..16777215  

acSS7SigTranRoutingContextOpc3 1.3.6.1.4.1.5003.9.10.12.1.5.24.1.10
This parameter is used to specify the M3UA Routing Context, Third element of OPC list. Access: Online. AC INI-Param: SS7_RC_OPC3
Status: current Access: read-create
OBJECT-TYPE    
  Integer32 -1..16777215  

acSS7SigTranRoutingContextOpc4 1.3.6.1.4.1.5003.9.10.12.1.5.24.1.11
This parameter is used to specify the M3UA Routing Context, Fourth element of OPC list. Access: Online. AC INI-Param: SS7_RC_OPC4
Status: current Access: read-create
OBJECT-TYPE    
  Integer32 -1..16777215  

acSS7SigTranRoutingContextSi1 1.3.6.1.4.1.5003.9.10.12.1.5.24.1.12
This parameter is used to specify the M3UA Routing Context, First element of SI list. Access: Online. AC INI-Param: SS7_RC_SI1
Status: current Access: read-create
OBJECT-TYPE    
  Integer32 -1..15  

acSS7SigTranRoutingContextSi2 1.3.6.1.4.1.5003.9.10.12.1.5.24.1.13
This parameter is used to specify the M3UA Routing Context, Second element of SI list. Access: Online. AC INI-Param: SS7_RC_SI2
Status: current Access: read-create
OBJECT-TYPE    
  Integer32 -1..15  

acSS7SigTranRoutingContextSi3 1.3.6.1.4.1.5003.9.10.12.1.5.24.1.14
This parameter is used to specify the M3UA Routing Context, Third element of SI list. Access: Online. AC INI-Param: SS7_RC_SI3
Status: current Access: read-create
OBJECT-TYPE    
  Integer32 -1..15  

acSS7SigTranRoutingContextSi4 1.3.6.1.4.1.5003.9.10.12.1.5.24.1.15
This parameter is used to specify the M3UA Routing Context, Fourth element of SI list. Access: Online. AC INI-Param: SS7_RC_SI4
Status: current Access: read-create
OBJECT-TYPE    
  Integer32 -1..15  

acSS7Redundancy 1.3.6.1.4.1.5003.9.10.12.1.6
OBJECT IDENTIFIER    

acSS7RedundancyCrossLinkTransferType 1.3.6.1.4.1.5003.9.10.12.1.6.1
Defines the cross-board connection media type for the MTP3 redundancy feature: 0 = M3BRDCY_CONN_TYPE_NONE 2 = M3BRDCY_CONN_TYPE_TCP. Access: Offline. AC INI-Param: SS7MTP3RdcyTransferType
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER none(0), tcp(2)  

acSS7RedundancyMode 1.3.6.1.4.1.5003.9.10.12.1.6.2
Defines the MTP3 Signaling redundancy mode: 0 = Disabled 1 = Enabled . Access: Offline. AC INI-Param: SS7MTP3RdcyMode
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disable(0), enable(1)  

acSS7RedundancyBoardNum 1.3.6.1.4.1.5003.9.10.12.1.6.3
Defines the board number for the SS7 (Signaling System 7) MTP3 redundancy mode. Each board is allocated a unique number. All boards share a single redundancy table. Access: Offline. AC INI-Param: SS7MTP3RdcyBoardNum
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 0..2  

acSS7RedundancyCrossLinkTraceAll 1.3.6.1.4.1.5003.9.10.12.1.6.4
When set via INI-file, activates trace output for all X-links (only when SS7 redundancy is configured). . Access: Instant. AC INI-Param: SS7M3BRdcyXlinkTraceAll
Status: obsolete Access: read-write
OBJECT-TYPE    
  INTEGER disable(0), enable(1)  

acSS7RedundancyMTP3RdcyTblSyncInterval 1.3.6.1.4.1.5003.9.10.12.1.6.5
Defines the interval between SS7 tables automatic synchronizations, in minutes. 0 = no automatic synchronization is activated. . Access: Instant. AC INI-Param: N/A
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 0..144000  

acSS7RedundancySyncAllBoards 1.3.6.1.4.1.5003.9.10.12.1.6.6
Provide SYNC all boards command. Access: Instant. AC INI-Param: N/A
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER noAction(0), sync(1)  

acSS7RedundancySyncBoard 1.3.6.1.4.1.5003.9.10.12.1.6.7
Provide SYNC between this board and another specific board (parameter is the remote board number). Access: Instant. AC INI-Param: N/A
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 0..2147483647  

acSS7RedundancyKeepAliveWindow 1.3.6.1.4.1.5003.9.10.12.1.6.8
Defines redundancy X-link keep-alive tolerance window. (x-link between boards in Signaling System 7 (SS7) MTP3-User Adaptation Layer redundancy mode). . Access: Offline. AC INI-Param: SS7MTP3RdcyKeepAliveWindow
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 1..15  

acSS7RedundancyKeepAliveInterval 1.3.6.1.4.1.5003.9.10.12.1.6.9
Defines redundancy X-link keep-alive interval in secs. (x-link between boards in Signaling System 7 (SS7) MTP3-User Adaptation Layer redundancy mode). 0 = no keep-alive mechanism is activated. . Access: Offline. AC INI-Param: SS7MTP3RdcyKeepAliveInterval
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 0..100  

acSS7RedundantSNTable 1.3.6.1.4.1.5003.9.10.12.1.6.21
Tok_String
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AcSS7RedundantSNEntry

acSS7RedundantSNEntry 1.3.6.1.4.1.5003.9.10.12.1.6.21.1
Tok_String
Status: current Access: not-accessible
OBJECT-TYPE    
  AcSS7RedundantSNEntry  

acSS7RedundantSNBoardIndex 1.3.6.1.4.1.5003.9.10.12.1.6.21.1.1
First index for a line: board number. AC INI-Param: SS7_RDCYSN_BOARD_INDEX
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32 1..4  

acSS7RedundantSNIndex 1.3.6.1.4.1.5003.9.10.12.1.6.21.1.2
Second index for a line: SN number in the board. AC INI-Param: SS7_RDCYSN_SN_INDEX
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32 0..2  

acSS7RedundantSNRowStatus 1.3.6.1.4.1.5003.9.10.12.1.6.21.1.3
ROWSTATUS field for line. AC INI-Param: SS7_RDCYSN_ROWSTATUS
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

acSS7RedundantSNAction 1.3.6.1.4.1.5003.9.10.12.1.6.21.1.4
Management field for ACTION. AC INI-Param: SS7_RDCYSN_ACTION
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32 0..2147483647  

acSS7RedundantSNActionRes 1.3.6.1.4.1.5003.9.10.12.1.6.21.1.5
Management field for ACTION RESULT. AC INI-Param: SS7_RDCYSN_ACTIONRES
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32 0..2147483647  

acSS7RedundantSNBoardIp 1.3.6.1.4.1.5003.9.10.12.1.6.21.1.6
IP address of the board. Access: Online. AC INI-Param: SS7_RDCYSN_BOARD_IP
Status: current Access: read-create
OBJECT-TYPE    
  IpAddress  

acSS7RedundantSNOPC 1.3.6.1.4.1.5003.9.10.12.1.6.21.1.7
Internal point-code of the SN (Signaling Node). Access: Online. AC INI-Param: SS7_RDCYSN_OPC
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32 0..2147483647  

acSS7RedundantSNALCAPOPC 1.3.6.1.4.1.5003.9.10.12.1.6.21.1.8
Internal point-code of ALCAP instance on a given board. Access: Online. AC INI-Param: SS7_RDCYSN_ALCAP_OPC
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32 0..2147483647  

acSS7Status 1.3.6.1.4.1.5003.9.10.12.2
OBJECT IDENTIFIER    

acSS7Constants 1.3.6.1.4.1.5003.9.10.12.2.1
OBJECT IDENTIFIER    

acSS7ConstantsNumberOfNodes 1.3.6.1.4.1.5003.9.10.12.2.1.1
AC INI-Param: N/A
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32 0..1000  


acSS7ConstantsNumberOfLinkSetsPerSN 1.3.6.1.4.1.5003.9.10.12.2.1.3
AC INI-Param: N/A
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32 0..1000  

acSS7ConstantsNumberOfLinksPerLinkSet 1.3.6.1.4.1.5003.9.10.12.2.1.4
AC INI-Param: N/A
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32 0..1000  

acSS7ConstantsNumberOfRouteSetsPerSN 1.3.6.1.4.1.5003.9.10.12.2.1.5
AC INI-Param: N/A
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32 0..1000  

acSS7ConstantsNumberOfRoutesPerRouteSets 1.3.6.1.4.1.5003.9.10.12.2.1.6
AC INI-Param: N/A
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32 0..1000  

acSS7ConstantsNumberOfNodeTimerSets 1.3.6.1.4.1.5003.9.10.12.2.1.7
AC INI-Param: N/A
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32 0..1000  

acSS7ConstantsNumberOfLinkSetTimerSets 1.3.6.1.4.1.5003.9.10.12.2.1.8
AC INI-Param: N/A
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32 0..1000