AC-PM-ATM-MIB

File: AC-PM-ATM-MIB.mib (14660 bytes)

Imported modules

SNMPv2-SMI

Imported symbols

Gauge32 Counter32 OBJECT-TYPE
MODULE-IDENTITY enterprises

Defined Types

AcPMAtmCellTxEntry  
SEQUENCE    
  acPMAtmCellTxInterface INTEGER
  acPMAtmCellTxInterval INTEGER
  acPMAtmCellTxAverage INTEGER
  acPMAtmCellTxMax INTEGER
  acPMAtmCellTxMin INTEGER
  acPMAtmCellTxVolume Counter32
  acPMAtmCellTxTimeBelowLowThreshold INTEGER
  acPMAtmCellTxTimeBetweenThresholds INTEGER
  acPMAtmCellTxTimeAboveHighThreshold INTEGER
  acPMAtmCellTxFullDayAverage INTEGER

AcPMAtmCellRxEntry  
SEQUENCE    
  acPMAtmCellRxInterface INTEGER
  acPMAtmCellRxInterval INTEGER
  acPMAtmCellRxAverage INTEGER
  acPMAtmCellRxMax INTEGER
  acPMAtmCellRxMin INTEGER
  acPMAtmCellRxVolume Counter32
  acPMAtmCellRxTimeBelowLowThreshold INTEGER
  acPMAtmCellRxTimeBetweenThresholds INTEGER
  acPMAtmCellRxTimeAboveHighThreshold INTEGER
  acPMAtmCellRxFullDayAverage INTEGER

AcPMAtmCellDiscardedEntry  
SEQUENCE    
  acPMAtmCellDiscardedInterface INTEGER
  acPMAtmCellDiscardedInterval INTEGER
  acPMAtmCellDiscardedVal Gauge32

Defined Values

audioCodes 1.3.6.1.4.1.5003
OBJECT IDENTIFIER    

acRegistrations 1.3.6.1.4.1.5003.7
OBJECT IDENTIFIER    

acGeneric 1.3.6.1.4.1.5003.8
OBJECT IDENTIFIER    

acProducts 1.3.6.1.4.1.5003.9
OBJECT IDENTIFIER    

acPerformance 1.3.6.1.4.1.5003.10
OBJECT IDENTIFIER    

acPMAtm 1.3.6.1.4.1.5003.10.12
The AC-PM-ATM MIB offers performance monitoring For the ATMrelated elements in Audiocodes' devices. The Configuration sub-tree is for configuring the interval Period length for the entire AC-PM-ATM MIB, and the different tables' thresholds. The Data sub-tree presents the tables of monitored elements. Note - for the entire MIB the value (-1) means the value Asked for is either not supported or currently not relevant (this is for when values asked for are for intervals not yet recorded.
MODULE-IDENTITY    

acPMAtmConfiguration 1.3.6.1.4.1.5003.10.12.1
OBJECT IDENTIFIER    

acPMAtmConfigurationPeriodLength 1.3.6.1.4.1.5003.10.12.1.1
Length of monitoring intervals for entire MIB.Time is in minutes.
OBJECT-TYPE    
  INTEGER 0..894780  

acPMAtmConfigurationResetTotalCounters 1.3.6.1.4.1.5003.10.12.1.2
Total-Counters Reset. To reset the total counters, set the value of this object to resetTotalCounters(2).
OBJECT-TYPE    
  INTEGER resetCountersDone(1), resetTotalCounters(2)  

acPMAtmCellAttributes 1.3.6.1.4.1.5003.10.12.1.31
OBJECT IDENTIFIER    

acPMAtmCellAttributesTxHighThreshold 1.3.6.1.4.1.5003.10.12.1.31.1
High threshold.
OBJECT-TYPE    
  INTEGER 100..3000  

acPMAtmCellAttributesTxLowThreshold 1.3.6.1.4.1.5003.10.12.1.31.2
Low threshold.
OBJECT-TYPE    
  INTEGER 100..3000  

acPMAtmCellAttributesRxHighThreshold 1.3.6.1.4.1.5003.10.12.1.31.3
High threshold.
OBJECT-TYPE    
  INTEGER 100..3000  

acPMAtmCellAttributesRxLowThreshold 1.3.6.1.4.1.5003.10.12.1.31.4
Low threshold.
OBJECT-TYPE    
  INTEGER 100..3000  

acPMAtmData 1.3.6.1.4.1.5003.10.12.2
OBJECT IDENTIFIER    

acPMAtmDataAcPMAtmTimeFromStartOfInterval 1.3.6.1.4.1.5003.10.12.2.1
The time in seconds since the start of the current interval. MIB specific.
OBJECT-TYPE    
  INTEGER 0..2147483647  

acPMAtmCellTxTable 1.3.6.1.4.1.5003.10.12.2.21
Atm interface transmit cells per second.
OBJECT-TYPE    
  SEQUENCE OF  
    AcPMAtmCellTxEntry

acPMAtmCellTxEntry 1.3.6.1.4.1.5003.10.12.2.21.1
Tok_String
OBJECT-TYPE    
  AcPMAtmCellTxEntry  

acPMAtmCellTxInterface 1.3.6.1.4.1.5003.10.12.2.21.1.1
Atm interface 0,1 and 2.
OBJECT-TYPE    
  INTEGER 0..2  

acPMAtmCellTxInterval 1.3.6.1.4.1.5003.10.12.2.21.1.2
Interval index. 0 - current period (incomplete monitoring - mid period). 1 - Last full period. 2 - One before last.
OBJECT-TYPE    
  INTEGER 0..2  

acPMAtmCellTxAverage 1.3.6.1.4.1.5003.10.12.2.21.1.3
Average value within the period time.
OBJECT-TYPE    
  INTEGER -1..2147483647  

acPMAtmCellTxMax 1.3.6.1.4.1.5003.10.12.2.21.1.4
Maximum value within the period time.
OBJECT-TYPE    
  INTEGER -1..2147483647  

acPMAtmCellTxMin 1.3.6.1.4.1.5003.10.12.2.21.1.5
Minimum value within the period time.
OBJECT-TYPE    
  INTEGER -1..2147483647  

acPMAtmCellTxVolume 1.3.6.1.4.1.5003.10.12.2.21.1.6
Activity volume.
OBJECT-TYPE    
  Counter32  

acPMAtmCellTxTimeBelowLowThreshold 1.3.6.1.4.1.5003.10.12.2.21.1.7
Percent of interval time for which gauge is below what was determined as the low threshold.
OBJECT-TYPE    
  INTEGER -1..100  

acPMAtmCellTxTimeBetweenThresholds 1.3.6.1.4.1.5003.10.12.2.21.1.8
Percent of interval time for which gauge is above what was determined as the high threshold.
OBJECT-TYPE    
  INTEGER -1..100  

acPMAtmCellTxTimeAboveHighThreshold 1.3.6.1.4.1.5003.10.12.2.21.1.9
Percent of interval time for which gauge is between what were determined as the low and high thresholds.
OBJECT-TYPE    
  INTEGER -1..100  

acPMAtmCellTxFullDayAverage 1.3.6.1.4.1.5003.10.12.2.21.1.10
The average of full 24 hours.
OBJECT-TYPE    
  INTEGER -1..2147483647  

acPMAtmCellRxTable 1.3.6.1.4.1.5003.10.12.2.22
Atm interface recieve cells per second.
OBJECT-TYPE    
  SEQUENCE OF  
    AcPMAtmCellRxEntry

acPMAtmCellRxEntry 1.3.6.1.4.1.5003.10.12.2.22.1
Tok_String
OBJECT-TYPE    
  AcPMAtmCellRxEntry  

acPMAtmCellRxInterface 1.3.6.1.4.1.5003.10.12.2.22.1.1
Atm interface 0,1 and 2.
OBJECT-TYPE    
  INTEGER 0..2  

acPMAtmCellRxInterval 1.3.6.1.4.1.5003.10.12.2.22.1.2
Interval index. 0 - current period (incomplete monitoring - mid period). 1 - Last full period. 2 - One before last.
OBJECT-TYPE    
  INTEGER 0..2  

acPMAtmCellRxAverage 1.3.6.1.4.1.5003.10.12.2.22.1.3
Average value within the period time.
OBJECT-TYPE    
  INTEGER -1..2147483647  

acPMAtmCellRxMax 1.3.6.1.4.1.5003.10.12.2.22.1.4
Maximum value within the period time.
OBJECT-TYPE    
  INTEGER -1..2147483647  

acPMAtmCellRxMin 1.3.6.1.4.1.5003.10.12.2.22.1.5
Minimum value within the period time.
OBJECT-TYPE    
  INTEGER -1..2147483647  

acPMAtmCellRxVolume 1.3.6.1.4.1.5003.10.12.2.22.1.6
Activity volume.
OBJECT-TYPE    
  Counter32  

acPMAtmCellRxTimeBelowLowThreshold 1.3.6.1.4.1.5003.10.12.2.22.1.7
Percent of interval time for which gauge is below what was determined as the low threshold.
OBJECT-TYPE    
  INTEGER -1..100  

acPMAtmCellRxTimeBetweenThresholds 1.3.6.1.4.1.5003.10.12.2.22.1.8
Percent of interval time for which gauge is above what was determined as the high threshold.
OBJECT-TYPE    
  INTEGER -1..100  

acPMAtmCellRxTimeAboveHighThreshold 1.3.6.1.4.1.5003.10.12.2.22.1.9
Percent of interval time for which gauge is between what were determined as the low and high thresholds.
OBJECT-TYPE    
  INTEGER -1..100  

acPMAtmCellRxFullDayAverage 1.3.6.1.4.1.5003.10.12.2.22.1.10
The average of full 24 hours.
OBJECT-TYPE    
  INTEGER -1..2147483647  

acPMAtmCellDiscardedTable 1.3.6.1.4.1.5003.10.12.2.23
Counts the number of cells discarded in the reporting interval.
OBJECT-TYPE    
  SEQUENCE OF  
    AcPMAtmCellDiscardedEntry

acPMAtmCellDiscardedEntry 1.3.6.1.4.1.5003.10.12.2.23.1
Tok_String
OBJECT-TYPE    
  AcPMAtmCellDiscardedEntry  

acPMAtmCellDiscardedInterface 1.3.6.1.4.1.5003.10.12.2.23.1.1
Atm interface 0,1 and 2.
OBJECT-TYPE    
  INTEGER 0..2  

acPMAtmCellDiscardedInterval 1.3.6.1.4.1.5003.10.12.2.23.1.2
Interval index. 0 - current period (incomplete monitoring - mid period). 1 - Last full period. 2 - One before last.
OBJECT-TYPE    
  INTEGER 0..2  

acPMAtmCellDiscardedVal 1.3.6.1.4.1.5003.10.12.2.23.1.3
Value of gauge or counter.
OBJECT-TYPE    
  Gauge32