AC-ANALOG-MIB

File: AC-ANALOG-MIB.mib (41126 bytes)

Imported modules

SNMPv2-SMI SNMPv2-TC RFC1155-SMI
SNMP-FRAMEWORK-MIB AUDIOCODES-TYPES-MIB

Imported symbols

OBJECT-TYPE MODULE-IDENTITY TAddress
DisplayString DateAndTime TEXTUAL-CONVENTION
IpAddress Unsigned32 Integer32
enterprises SnmpAdminString audioCodes
acRegistrations acGeneric acProducts
acBoardMibs

Defined Types

AcAnalogFxoFarEndDisconnectToneEntry  
SEQUENCE    
  acAnalogFxoFarEndDisconnectToneRowStatus Unsigned32
  acAnalogFxoFarEndDisconnectToneAction Unsigned32
  acAnalogFxoFarEndDisconnectToneActionResult Unsigned32
  acAnalogFxoFarEndDisconnectToneIndex Unsigned32
  acAnalogFxoFarEndDisconnectToneType INTEGER

AcAnalogFxsFxoEntry  
SEQUENCE    
  acAnalogFxsFxoIndex Unsigned32
  acAnalogFxsFxoType INTEGER
  acAnalogFxsFxoChipRevNum Unsigned32
  acAnalogFxsFxoHookState INTEGER

AcAnalogFxoLineTestEntry  
SEQUENCE    
  acAnalogFxoLineTestIndex Unsigned32
  acAnalogFxoLineTestActivate INTEGER
  acAnalogFxoLineTestHookState INTEGER
  acAnalogFxoLineTestPolarityStatus INTEGER
  acAnalogFxoLineTestLineConnectionStatus INTEGER
  acAnalogFxoLineTestLineCurrent Integer32
  acAnalogFxoLineTestLineVoltage Integer32
  acAnalogFxoLineTestRingState INTEGER
  acAnalogFxoLineTestLinePolarity INTEGER
  acAnalogFxoLineTestMwiState INTEGER
  acAnalogFxoLineTestLastCurrentDisconnectDuration Unsigned32

AcAnalogFxsLineTestEntry  
SEQUENCE    
  acAnalogFxsLineTestIndex Unsigned32
  acAnalogFxsLineTestActivate INTEGER
  acAnalogFxsLineTestHookState INTEGER
  acAnalogFxsLineTestRingState INTEGER
  acAnalogFxsLineTestPolarityStatus INTEGER
  acAnalogFxsLineTestMessageWaitingIndication INTEGER
  acAnalogFxsLineTestLineCurrentReading Unsigned32
  acAnalogFxsLineTestLineVoltageReading Integer32
  acAnalogFxsLineTestAnalogVoltageReading Unsigned32
  acAnalogFxsLineTestRingVoltageReading Integer32
  acAnalogFxsLineTestLongLineCurrentReading Unsigned32

AcAnalogCommonChannelEntry  
SEQUENCE    
  acAnalogCommonChannelIndex Unsigned32
  acAnalogCommonChannelAction INTEGER

AcAnalogLegsEntry  
SEQUENCE    
  acAnalogLegsLegIndex Unsigned32
  acAnalogLegsCallIndex Unsigned32
  acAnalogLegsAnalogType INTEGER
  acAnalogLegsEchoCanceller INTEGER
  acAnalogLegsHighPassFilter INTEGER
  acAnalogLegsDTMFDetection INTEGER
  acAnalogLegsVoiceVolume Unsigned32
  acAnalogLegsInputGain Unsigned32
  acAnalogLegsLegName SnmpAdminString

Defined Values

acAnalog 1.3.6.1.4.1.5003.9.10.8
Tok_String
MODULE-IDENTITY    

acAnalogConfiguration 1.3.6.1.4.1.5003.9.10.8.1
OBJECT IDENTIFIER    

acAnalogConfig 1.3.6.1.4.1.5003.9.10.8.1.1
OBJECT IDENTIFIER    

acAnalogMisc 1.3.6.1.4.1.5003.9.10.8.1.1.1
OBJECT IDENTIFIER    

acAnalogMiscCurrentDisconnectDuration 1.3.6.1.4.1.5003.9.10.8.1.1.1.1
Defines the current-disconnect duration (in msec). This value is used in generation and detection. Access: Offline. AC INI-Param: CurrentDisconnectDuration
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 200..1500  

acAnalogMiscFlashHookPeriod 1.3.6.1.4.1.5003.9.10.8.1.1.1.2
Defines the flashhook period (in msec) for both analog and IP sides. For the analog side it defines: - The maximal hook-flash detection period (for FXS gateways). A longer signal is considered offhook / onhook event. - The hook-flash generation period (for FXO gateways). For the IP side it defines the flash-hook period that is reported to IP. The valid range is 25 to 1500. The default value is 700 msec. Note: For FXO gateways, a constant of 90 msec must be added to the required hook-flash period. For example, to generate a 450 msec hook-flash, set 'FlashHookPeriod' to 540. . Access: Instant. AC INI-Param: FLASHHOOKPERIOD
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 25..3000  

acAnalogMiscGroundKeyDetection 1.3.6.1.4.1.5003.9.10.8.1.1.1.3
Enables/disables the analog ground key detection. 0 = Disable 1= Enable. Access: Offline. AC INI-Param: GroundKeyDetection
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disable(0), enable(1)  

acAuxiliaryFiles 1.3.6.1.4.1.5003.9.10.8.1.1.2
OBJECT IDENTIFIER    

acAuxiliaryFilesFxsCoefficients 1.3.6.1.4.1.5003.9.10.8.1.1.2.1
Defines the FXS coefficient file name. AC INI-Param: FXSCOEFFILENAME
Status: current Access: read-only
OBJECT-TYPE    
  SnmpAdminString Size(0..47)  

acAuxiliaryFilesFxoCoefficients 1.3.6.1.4.1.5003.9.10.8.1.1.2.2
Defines the FXO coefficient filename. Max. 47 characters. AC INI-Param: FXOCOEFFILENAME
Status: current Access: read-only
OBJECT-TYPE    
  SnmpAdminString Size(0..47)  

acAnalogFxoConfig 1.3.6.1.4.1.5003.9.10.8.1.2
OBJECT IDENTIFIER    

acAnalogFxo 1.3.6.1.4.1.5003.9.10.8.1.2.1
OBJECT IDENTIFIER    

acAnalogFxoFarEndDisconnectType 1.3.6.1.4.1.5003.9.10.8.1.2.1.1
This parameter sets the source for the acEV_FAR_END_DISCONNECTED event (or for the relevant control protocol event). It is a bit field parameter, hence (for example) if both CPT and current disconnect are required, the parameter should be set to 5. FarDisconnect contributor: 1 = CPT 2 = PolarityReversal 4 = CurrentDisconnect 8 = Silence. Access: Offline. AC INI-Param: FARENDDISCONNECTTYPE
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 0..128  

acAnalogFxoCountryCoefficients 1.3.6.1.4.1.5003.9.10.8.1.2.1.2
Allows the user to modify the line characteristic (AC and DC) according to country. Access: Offline. AC INI-Param: CountryCoefficients
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER europe(66), unitedStates(70)  

acAnalogFxoDCRemover 1.3.6.1.4.1.5003.9.10.8.1.2.1.3
Determines whether to enable the analog DC remover in the DAA. One of the following values: 0 = DC remover is disabled 1 = DC remover is enabled. Access: Offline. AC INI-Param: EnableAnalogDCRemover
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disable(0), enable(1)  

acAnalogFxoFarEndDisconnectToneTable 1.3.6.1.4.1.5003.9.10.8.1.2.1.21
Tok_String
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AcAnalogFxoFarEndDisconnectToneEntry

acAnalogFxoFarEndDisconnectToneEntry 1.3.6.1.4.1.5003.9.10.8.1.2.1.21.1
Tok_String
Status: current Access: not-accessible
OBJECT-TYPE    
  AcAnalogFxoFarEndDisconnectToneEntry  

acAnalogFxoFarEndDisconnectToneRowStatus 1.3.6.1.4.1.5003.9.10.8.1.2.1.21.1.1
Far End Disconnect table row-status. AC INI-Param: N/A
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 1..1  

acAnalogFxoFarEndDisconnectToneAction 1.3.6.1.4.1.5003.9.10.8.1.2.1.21.1.2
Far End Disconnect table action. AC INI-Param: N/A
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 0..0  

acAnalogFxoFarEndDisconnectToneActionResult 1.3.6.1.4.1.5003.9.10.8.1.2.1.21.1.3
Far End Disconnect table result. AC INI-Param: N/A
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32 0..0  

acAnalogFxoFarEndDisconnectToneIndex 1.3.6.1.4.1.5003.9.10.8.1.2.1.21.1.4
Index for table use. AC INI-Param: N/A
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32 0..4  

acAnalogFxoFarEndDisconnectToneType 1.3.6.1.4.1.5003.9.10.8.1.2.1.21.1.5
Defines which CPT types are detected as far-end disconnect. The CPT type is based on the acTCallProgressToneType enum. This is valid when FarEndDisconnectType allows CPT detection. Range = An array of up to 4 tone types. Access: Offline. AC INI-Param: DISCONNECTTONETYPE
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER acNullTone(0), acDialTone(1), acRingingTone(2), acBusyTone(3), acCongestionTone(4), acSpecialInfoTone(5), acWarningTone(6), acReorderTone(7), acConfirmationTone(8), acWaitingTone(9), acCallProgressCo1Tone(10), acCallProgressCo2Tone(11), acOldMilliwattTone(12), acNewMilliwattTone(13), acMessageWaitingIndicator(14), acStutterDialTone(15), acStutterOffHookWarningTone(16), acWaitingTone1(17), acComfortTone(18), acNAKTone(19), acVacantNumberTone(20), acSpecialConditionTone(21), acDialTone2(22), acOnHoldTone(23), acCallTransferDialTone(24), acCallForwardTone(25), acCreditCardServiceTone(26), acSpecialRecallDialTone(27), acAlertingTone(28), acNetworkCongestionTone(29), acWaitingTone2(30), acWaitingTone3(31), acWaitingTone4(32), acConfEnterTone(33), acConfExitTone(34), acConfLockTone(35), acConfUnlockTone(36), acConfTimeLimitTone(37), acPayphoneRecognitionTone(38), acCallerWaitingTone(39), acCNGFaxTone(40), acPrecConfNotifyType(41), acPresConfNotifyType(42), acPrecPreemptType(43), acPrecRTType(44), acR15reqOfANItone(45), acCo1Tone(200), acCo2Tone(201), acPlayRecordBeepTone(202), acTrunkTestingTestProgressTone(203), acTrunkTestingTestTone(204), acTrunkTestingGuardTone(205), acFSKTrunkTestingTone(206), acGeneralTrunkTestingTone1(207), acGeneralTrunkTestingTone2(208), acGeneralTrunkTestingTone3(209), acSpecialInfoToneFirst(210), acSpecialInfoToneSecond(211), acSpecialInfoToneThird(212), acTTYTone(213), acTT904ContinuityTone(214), acTTMilliwattLossMeasureTone(215), acCarrierDialTone(216), acCarrierAnswerTone(217), acCarrierChargingTone(218), acLongDistanceIndicatorTone(219), acSTUModemFirstTone(298), acSTUModemSecondTone(299)  

acAnalogFxsConfig 1.3.6.1.4.1.5003.9.10.8.1.3
OBJECT IDENTIFIER    

acAnalogFxs 1.3.6.1.4.1.5003.9.10.8.1.3.1
OBJECT IDENTIFIER    

acAnalogFxsPolarityReversalType 1.3.6.1.4.1.5003.9.10.8.1.3.1.1
Sets the type of the polarity reversal signal used for the network far-end answer and disconnect indications. Smooth reversal prevents negative effects as non-required ringing. 0 = Soft reverse polarity 1 = Hard reverse polarity. Access: Offline. AC INI-Param: POLARITYREVERSALTYPE
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER soft(0), hard(1)  

acAnalogFxsMeteringType 1.3.6.1.4.1.5003.9.10.8.1.3.1.2
Sets the metering method for charging pulses. 0 = 12 kHz sinusoidal bursts 1 = 16 kHz sinusoidal bursts 2 = Polarity Reversal pulses. Access: Offline. AC INI-Param: METERINGTYPE
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER mt12kHz(0), mt16kHz(1), mtPolarityReversal(2)  

acAnalogFxsLifeLineType 1.3.6.1.4.1.5003.9.10.8.1.3.1.3
Defines the Lifeline phone type. The Lifeline phone is available (for FXS only) on port 4 in MP-104 and MP-108, on port 2 in MP-102, on ports 1-4 in the MP-118, and on port 2 of each analog module in the Mediant 1000. 0 = activate Lifeline phone on power down 1 = activate Lifeline phone on power down or on detection of LAN disconnect 2 = activate Lifeline phone on power down, or on detection of LAN disconnect, or on loss of ping. Access: Offline. AC INI-Param: LIFELINETYPE
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER acLifeLineType-Hardware-Only(0), acLifeLineTypeHardware-And-Link-Detection(1), acLifeLineType-Hardware-And-Link-And-Network-Detection(2)  

acAnalogFxsMinFlashHookTime 1.3.6.1.4.1.5003.9.10.8.1.3.1.4
Sets the minimal time (in msec) for detection of a flash-hook event (for FXS only). The valid range is 25 to 300. The default value is 300 msec. Detection is guaranteed for flash hook periods of at least 60 msec (when setting the minimal time to 25). Flash-hook signals that last a shorter period of time are ignored. Note: It is recommended to reduce the detection time by 50 msec from the desired value (e.g. if you set the value as 200 msec, then enter 150 msec, i.e. 200 minus 50). . Access: Offline. AC INI-Param: MINFLASHHOOKTIME
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 25..300  

acAnalogFxsCallerIDTimingMode 1.3.6.1.4.1.5003.9.10.8.1.3.1.5
Defines the Analog CallerID Timing Mode. 0 = CallerID transferred between first and second rings 1 = CallerID transferred on valid Off ring. Access: Offline. AC INI-Param: ANALOGCALLERIDTIMINGMODE
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disable(0), enable(1)  

acAnalogFxsBellcoreCallerIDTypeOneSubStandard 1.3.6.1.4.1.5003.9.10.8.1.3.1.6
Selects the sub-standard of the Bellcore Caller ID type. 0 = Between_Rings 1 = Not_Ring_Related 2 = Before_Ring_RP_AS. Access: Offline. AC INI-Param: BellcoreCallerIDTypeOneSubStandard
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER bellcore-Between-Rings(0), bellcore-Not-Ring-Related(1), bellcore-Before-Ring-RP-AS(2)  

acAnalogFxsETSICallerIDTypeOneSubStandard 1.3.6.1.4.1.5003.9.10.8.1.3.1.7
Selects the number denoting the ETSI CallerID Type 1 sub-standard. Either: 0 = ETSI_Between_Rings 1 = ETSI_Before_Ring_DT_AS 2 = ETSI_Before_Ring_RP_AS 3 = ETSI_Before_Ring_LR_DT_AS 4 = ETSI_Not_Ring_Related_DT_AS 5 = ETSI_Not_Ring_Related_RP_AS 6 = ETSI_Not_Ring_Related_LR_DT_AS. Access: Offline. AC INI-Param: ETSICallerIDTypeOneSubStandard
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER eTSI-Between-Rings(0), eTSI-Before-Ring-DT-AS(1), eTSI-Before-Ring-RP-AS(2), eTSI-Before-Ring-LR-DT-AS(3), eTSI-Not-Ring-Related-DT-AS(4), eTSI-Not-Ring-Related-RP-AS(5), eTSI-Not-Ring-Related-LR-DT-AS(6)  

acAnalogFxsETSIVMWITypeOneStandard 1.3.6.1.4.1.5003.9.10.8.1.3.1.8
Selects the number denoting the ETSI VMWI Type 1 Standard. Choose: 0 = ETSI_VMWI_Between_Rings 1 = ETSI_VMWI_Before_Ring_DT_AS 2 = ETSI_VMWI_Before_Ring_RP_AS 3 = ETSI_VMWI_Before_Ring_LR_DT_AS 4 = ETSI_VMWI_Not_Ring_Related_DT_AS 5 = ETSI_VMWI_Not_Ring_Related_RP_AS 6 = ETSI_VMWI_Not_Ring_Related_LR_DT_AS. Access: Offline. AC INI-Param: ETSIVMWITypeOneStandard
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER eTSI-VMWI-Between-Rings(0), eTSI-VMWI-Before-Ring-DT-AS(1), eTSI-VMWI-Before-Ring-RP-AS(2), eTSI-VMWI-Before-Ring-LR-DT-AS(3), eTSI-VMWI-Not-Ring-Related-DT-AS(4), eTSI-VMWI-Not-Ring-Related-RP-AS(5), eTSI-VMWI-Not-Ring-Related-LR-DT-AS(6)  

acAnalogFxsBellcoreVMWITypeOneStandard 1.3.6.1.4.1.5003.9.10.8.1.3.1.9
Use this parameter to select the Bellcore VMWI standard. 0 - Between_Rings 1 - Not_Ring_Related. Access: Offline. AC INI-Param: BellcoreVMWITypeOneStandard
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER bellcore-VMWI-Between-Rings(0), bellcore-VMWI-Not-Ring-Related(1)  

acAnalogFxsDisableAutoCalibration 1.3.6.1.4.1.5003.9.10.8.1.3.1.10
Determines whether to enable the analog Autocalibration in the DAA. One of the following values: 0 = Auto calibration is enabled 1 = Auto calibration is disabled. Access: Offline. AC INI-Param: DisableAnalogAutoCalibration
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32  

acAnalogFxsExternalLifeLinePorts 1.3.6.1.4.1.5003.9.10.8.1.3.1.11
Set the amount of FXS ports which will be connected to an external life line and will be disabled (max value is half of the FXS ports). Access: Offline. AC INI-Param: ExternalLifeLinePorts
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 0..24  

acAnalogFxsCountryCoefficients 1.3.6.1.4.1.5003.9.10.8.1.3.1.12
Allows the user to modify the line characteristic (AC and DC) according to country. Access: Offline. AC INI-Param: FXSCountryCoefficients
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER europe(66), unitedStates(70)  

acAnalogFxsTTXVoltageLevel 1.3.6.1.4.1.5003.9.10.8.1.3.1.13
Sets the TTX pulses voltage level. 0 = 0Vrms sinusoidal bursts 1 = 0.5Vrms sinusoidal bursts 2 = 1Vrms sinusoidal bursts -1 = notAvailable. Access: Offline. AC INI-Param: AnalogTTXVoltageLevel
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notAvailable(-1), ttxVoltageLevel0V(0), ttxVoltageLevel05(1), ttxVoltageLevel1V(2)  

acAnalogStatus 1.3.6.1.4.1.5003.9.10.8.2
OBJECT IDENTIFIER    

acAnalogStatusMisc 1.3.6.1.4.1.5003.9.10.8.2.1
OBJECT IDENTIFIER    

acAnalogStatusMiscFxsOrFxo 1.3.6.1.4.1.5003.9.10.8.2.1.1
Board is Fxs Or Fxo (For all devices except MP118). For MP118 - see acAnalogFxsFxoType for a line specific status. AC INI-Param: N/A
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER fXO(0), fXS(1)  

acAnalogStatusMiscBoardTemperature 1.3.6.1.4.1.5003.9.10.8.2.1.2
Temperature of the board in degrees Celsius, should not go higher then 60!. AC INI-Param: N/A
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32 0..100  

acAnalogStatusMiscAnalogChannelsCount 1.3.6.1.4.1.5003.9.10.8.2.1.3
Number of the Analog channels in the board. AC INI-Param: N/A
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32 0..5000  

acAnalogFxsFxo 1.3.6.1.4.1.5003.9.10.8.2.20
OBJECT IDENTIFIER    

acAnalogFxsFxoTable 1.3.6.1.4.1.5003.9.10.8.2.20.1
Tok_String
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AcAnalogFxsFxoEntry

acAnalogFxsFxoEntry 1.3.6.1.4.1.5003.9.10.8.2.20.1.1
Tok_String
Status: current Access: not-accessible
OBJECT-TYPE    
  AcAnalogFxsFxoEntry  

acAnalogFxsFxoIndex 1.3.6.1.4.1.5003.9.10.8.2.20.1.1.1
Index for table use. AC INI-Param: N/A
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32 0..24  

acAnalogFxsFxoType 1.3.6.1.4.1.5003.9.10.8.2.20.1.1.2
Line is Fxs Or Fxo. AC INI-Param: N/A
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER fXO(0), fXS(1)  

acAnalogFxsFxoChipRevNum 1.3.6.1.4.1.5003.9.10.8.2.20.1.1.3
Fxs/Fxo's Chip revision number. AC INI-Param: N/A
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32 0..2147483647  

acAnalogFxsFxoHookState 1.3.6.1.4.1.5003.9.10.8.2.20.1.1.4
The hook state of the analog line. AC INI-Param: N/A
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER onHookState(1), offHookState(2)  

acAnalogAction 1.3.6.1.4.1.5003.9.10.8.3
OBJECT IDENTIFIER    

acAnalogFxoAction 1.3.6.1.4.1.5003.9.10.8.3.1
OBJECT IDENTIFIER    

acAnalogFxoLineTestTable 1.3.6.1.4.1.5003.9.10.8.3.1.1
Tok_String
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AcAnalogFxoLineTestEntry

acAnalogFxoLineTestEntry 1.3.6.1.4.1.5003.9.10.8.3.1.1.1
Tok_String
Status: current Access: not-accessible
OBJECT-TYPE    
  AcAnalogFxoLineTestEntry  

acAnalogFxoLineTestIndex 1.3.6.1.4.1.5003.9.10.8.3.1.1.1.1
Index for table use. AC INI-Param: N/A
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32 0..24  

acAnalogFxoLineTestActivate 1.3.6.1.4.1.5003.9.10.8.3.1.1.1.2
Activate line testing in an FXO analog line according to a given line-index. AC INI-Param: N/A
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER noTestActivated(0), runLineTest(1), lineTestDone(2), testFailed(3)  

acAnalogFxoLineTestHookState 1.3.6.1.4.1.5003.9.10.8.3.1.1.1.3
The hook state of the analog line. AC INI-Param: N/A
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER onHookState(1), offHookState(2)  

acAnalogFxoLineTestPolarityStatus 1.3.6.1.4.1.5003.9.10.8.3.1.1.1.4
The line's polarity state. AC INI-Param: N/A
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER normalPolarity(1), reversePolarity(2), notAvailable(3)  

acAnalogFxoLineTestLineConnectionStatus 1.3.6.1.4.1.5003.9.10.8.3.1.1.1.5
The connection's status of the line. AC INI-Param: N/A
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER lineDisconnected(1), lineConnected(2)  

acAnalogFxoLineTestLineCurrent 1.3.6.1.4.1.5003.9.10.8.3.1.1.1.6
The line's current [ma]. AC INI-Param: N/A
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 -1..24  

acAnalogFxoLineTestLineVoltage 1.3.6.1.4.1.5003.9.10.8.3.1.1.1.7
The line's voltage [V]. AC INI-Param: N/A
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 -128..128  

acAnalogFxoLineTestRingState 1.3.6.1.4.1.5003.9.10.8.3.1.1.1.8
The Ring's State. AC INI-Param: N/A
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER off(1), on(2)  

acAnalogFxoLineTestLinePolarity 1.3.6.1.4.1.5003.9.10.8.3.1.1.1.9
The line's polarity state. AC INI-Param: N/A
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER positive(1), negative(2)  

acAnalogFxoLineTestMwiState 1.3.6.1.4.1.5003.9.10.8.3.1.1.1.10
Mwi's state. AC INI-Param: N/A
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER off(1), on(2)  

acAnalogFxoLineTestLastCurrentDisconnectDuration 1.3.6.1.4.1.5003.9.10.8.3.1.1.1.11
Last current disconnect duration in msec. AC INI-Param: N/A
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32 0..2147483647  

acAnalogFxsAction 1.3.6.1.4.1.5003.9.10.8.3.2
OBJECT IDENTIFIER    

acAnalogFxsLineTestTable 1.3.6.1.4.1.5003.9.10.8.3.2.1
Tok_String
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AcAnalogFxsLineTestEntry

acAnalogFxsLineTestEntry 1.3.6.1.4.1.5003.9.10.8.3.2.1.1
Tok_String
Status: current Access: not-accessible
OBJECT-TYPE    
  AcAnalogFxsLineTestEntry  

acAnalogFxsLineTestIndex 1.3.6.1.4.1.5003.9.10.8.3.2.1.1.1
Index for table use. AC INI-Param: N/A
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32 0..24  

acAnalogFxsLineTestActivate 1.3.6.1.4.1.5003.9.10.8.3.2.1.1.2
Activate line testing in a FXS analog line according to a given line-index. AC INI-Param: N/A
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER noTestActivated(0), runLineTest(1), lineTestDone(2), testFailed(3)  

acAnalogFxsLineTestHookState 1.3.6.1.4.1.5003.9.10.8.3.2.1.1.3
The hook state of the analog line. AC INI-Param: N/A
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER onHookState(1), offHookState(2)  

acAnalogFxsLineTestRingState 1.3.6.1.4.1.5003.9.10.8.3.2.1.1.4
Line's ring state. AC INI-Param: N/A
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER offRingState(1), onRingState(2)  

acAnalogFxsLineTestPolarityStatus 1.3.6.1.4.1.5003.9.10.8.3.2.1.1.5
Line's reversal-polarity. AC INI-Param: N/A
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER normalPolarity(1), reversePolarity(2)  

acAnalogFxsLineTestMessageWaitingIndication 1.3.6.1.4.1.5003.9.10.8.3.2.1.1.6
Line's messgae waiting indication state. AC INI-Param: N/A
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER noWaitingMessage(1), waitingMessage(2)  

acAnalogFxsLineTestLineCurrentReading 1.3.6.1.4.1.5003.9.10.8.3.2.1.1.7
The Line current reading in 10ua units. This test is supported only in line no. 0. Not supported on MP500. In case of MP124 this test is supported in all ports except ports 2 and 3. AC INI-Param: N/A
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32 0..3000  

acAnalogFxsLineTestLineVoltageReading 1.3.6.1.4.1.5003.9.10.8.3.2.1.1.8
The Line voltage reading in 10mV units. In case of MP124 the Line voltage reading in 1V units. This test is supported only in line no. 0. Not supported on MP500. In case of MP124 this test is supported in all ports except ports 2 and 3. AC INI-Param: N/A
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 -6000..6000  

acAnalogFxsLineTestAnalogVoltageReading 1.3.6.1.4.1.5003.9.10.8.3.2.1.1.9
The current analog voltage reading in 10mV units. his test is supported only in line no. 0. Not supported on MP500. In case of MP124 this test is supported in all ports except ports 2 and 3. AC INI-Param: N/A
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32 300..340  

acAnalogFxsLineTestRingVoltageReading 1.3.6.1.4.1.5003.9.10.8.3.2.1.1.10
The current ring voltage reading in 10mV units. This test is supported only in line no. 0. Not supported on MP500. In case of MP124 this test is supported in all ports except ports 2 and 3. AC INI-Param: N/A
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 -13000..13000  

acAnalogFxsLineTestLongLineCurrentReading 1.3.6.1.4.1.5003.9.10.8.3.2.1.1.11
The current long line reading in 10ua units. This test is supported only in line no. 0. Not supported on MP500. In case of MP124 this test is supported in all ports except ports 2 and 3. AC INI-Param: N/A
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32 0..4000  

acAnalogCommonAction 1.3.6.1.4.1.5003.9.10.8.3.3
OBJECT IDENTIFIER    

acAnalogCommonChannelTable 1.3.6.1.4.1.5003.9.10.8.3.3.1
Table for common channels operations.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AcAnalogCommonChannelEntry

acAnalogCommonChannelEntry 1.3.6.1.4.1.5003.9.10.8.3.3.1.1
Tok_String
Status: current Access: not-accessible
OBJECT-TYPE    
  AcAnalogCommonChannelEntry  

acAnalogCommonChannelIndex 1.3.6.1.4.1.5003.9.10.8.3.3.1.1.1
Index for table use, the current channel. AC INI-Param: N/A
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32 0..5000  

acAnalogCommonChannelAction 1.3.6.1.4.1.5003.9.10.8.3.3.1.1.2
An action to make on the current channel, The Reset action is for Analog channels only. AC INI-Param: N/A
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER noAction(0), reset(1)  

acAnalogLegs 1.3.6.1.4.1.5003.9.10.8.2.21
OBJECT IDENTIFIER    

acAnalogLegsTable 1.3.6.1.4.1.5003.9.10.8.2.21.1
Tok_String
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AcAnalogLegsEntry

acAnalogLegsEntry 1.3.6.1.4.1.5003.9.10.8.2.21.1.1
Tok_String
Status: current Access: not-accessible
OBJECT-TYPE    
  AcAnalogLegsEntry  

acAnalogLegsLegIndex 1.3.6.1.4.1.5003.9.10.8.2.21.1.1.1
Decribes The Digital EndPoint In A Call. AC INI-Param: N/A
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32 0..5000  

acAnalogLegsCallIndex 1.3.6.1.4.1.5003.9.10.8.2.21.1.1.2
Decribes The Call which The Rtp EndPoint Participant In It. AC INI-Param: N/A
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32 0..5000  

acAnalogLegsAnalogType 1.3.6.1.4.1.5003.9.10.8.2.21.1.1.3
Describs whether the board is FXS or FXO. AC INI-Param: N/A
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER fxs(1), fxo(2)  

acAnalogLegsEchoCanceller 1.3.6.1.4.1.5003.9.10.8.2.21.1.1.4
Enables or Disables the Echo Canceller. AC INI-Param: N/A
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER disable(0), enable(1)  

acAnalogLegsHighPassFilter 1.3.6.1.4.1.5003.9.10.8.2.21.1.1.5
Enables or Disables theHigh Pass Filter. AC INI-Param: N/A
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER disable(0), enable(1)  

acAnalogLegsDTMFDetection 1.3.6.1.4.1.5003.9.10.8.2.21.1.1.6
Enables or Disables the DTMF Detection. AC INI-Param: N/A
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER disable(0), enable(1)  

acAnalogLegsVoiceVolume 1.3.6.1.4.1.5003.9.10.8.2.21.1.1.7
Describs the volume of the voice in dB. AC INI-Param: N/A
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32 0..20000  

acAnalogLegsInputGain 1.3.6.1.4.1.5003.9.10.8.2.21.1.1.8
Describes the Input Gain on the leg in dB. AC INI-Param: N/A
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32 0..20000  

acAnalogLegsLegName 1.3.6.1.4.1.5003.9.10.8.2.21.1.1.9
Describes the Leg Name as in the Control Protocol. AC INI-Param: N/A
Status: current Access: read-only
OBJECT-TYPE    
  SnmpAdminString Size(0..64)