A3Com-System-r8-MIB

File: A3Com-System-r8-MIB.mib (117407 bytes)

Imported modules

RFC1155-SMI RFC1213-MIB RFC1286-MIB
RFC-1215 RFC-1212

Imported symbols

enterprises IpAddress Counter
TimeTicks DisplayString MacAddress
TRAP-TYPE OBJECT-TYPE

Defined Types

RowStatus  
INTEGER active(1), notInService(2), notReady(3), createAndGo(4), createAndWait(5), destroy(6)    

A3sysChipEntry  
SEQUENCE    
  a3sysChipSlotIndex INTEGER
  a3sysChipIndex INTEGER
  a3sysChipName DisplayString
  a3sysChipDescr DisplayString

A3sysMemEntry  
SEQUENCE    
  a3sysMemSlotIndex INTEGER
  a3sysMemIndex INTEGER
  a3sysMemType INTEGER
  a3sysMemStartAdd INTEGER
  a3sysMemSize INTEGER

A3sysBrdEntry  
SEQUENCE    
  a3sysSlotIndex INTEGER
  a3sysBrdDescr DisplayString
  a3sysBrdPathCapacity INTEGER
  a3sysBrdOID OBJECT IDENTIFIER
  a3sysBrdReset INTEGER
  a3sysBrdFwVers OBJECT IDENTIFIER

A3sysSNMPCommEntry  
SEQUENCE    
  a3sysSNMPCommString DisplayString Size(1..15)
  a3sysSNMPCommAccess INTEGER
  a3sysSNMPCommTrap INTEGER
  a3sysSNMPCommStatus RowStatus

A3sysSNMPMgrEntry  
SEQUENCE    
  a3sysSNMPMgrCommString DisplayString Size(1..15)
  a3sysSNMPMgrAddress IpAddress
  a3sysSNMPMgrMask IpAddress
  a3sysSNMPMgrStatus RowStatus

A3sysTelnetMgrEntry  
SEQUENCE    
  a3sysTelnetMgrAddress IpAddress
  a3sysTelnetMgrStatus RowStatus

A3sysPasswordEntry  
SEQUENCE    
  a3sysPwStatus INTEGER
  a3sysUserName DisplayString
  a3sysUserLevel INTEGER
  a3sysOldPassword DisplayString
  a3sysNewPassword DisplayString

A3sysUserBootListEntry  
SEQUENCE    
  a3sysUblSource INTEGER
  a3sysUblDevice INTEGER
  a3sysUblFileName DisplayString
  a3sysUblNetFile DisplayString
  a3sysUblSlot INTEGER
  a3sysUblInterface INTEGER
  a3sysUblMaxRetries INTEGER
  a3sysUblConfigFileDevice INTEGER
  a3sysUblConfigFilePath DisplayString
  a3sysUblConfigProt INTEGER
  a3sysUblConfigUserName DisplayString Size(0..20)
  a3sysUblConfigPassword DisplayString Size(0..20)
  a3sysUblConfigAcct DisplayString Size(0..30)
  a3sysUblMacAddress INTEGER
  a3sysUblCanonicalFlag INTEGER
  a3sysUblRemoteProt INTEGER
  a3sysUblBaudRate INTEGER
  a3sysUblClockSource INTEGER
  a3sysUblConnectorType INTEGER
  a3sysUblWanAddress DisplayString Size(0..80)
  a3sysUblClientIpAddr IpAddress
  a3sysUblServerIpAddr IpAddress
  a3sysUblGwIpAddr IpAddress
  a3sysUblConfigFileIpAddr IpAddress
  a3sysUblIpMask IpAddress
  a3sysUblAddressDiscovery INTEGER
  a3sysUblPassword DisplayString

A3sysIioBootEntry  
SEQUENCE    
  a3sysIioBootSlot INTEGER
  a3sysIioBootFileName DisplayString
  a3sysIioBootState INTEGER
  a3sysIioBootTime TimeTicks
  a3sysIioBootImage OBJECT IDENTIFIER

A3sysDfEntry  
SEQUENCE    
  a3sysDfName DisplayString
  a3sysDfDir INTEGER

A3sysIioRecoveryEntry  
SEQUENCE    
  a3sysIioRecoverySlot INTEGER
  a3sysIioRecoveryProcedure INTEGER
  a3sysIioRecoverySelect INTEGER

Defined Values

a3Com 1.3.6.1.4.1.43
OBJECT IDENTIFIER    

brouterMIB 1.3.6.1.4.1.43.2
OBJECT IDENTIFIER    

a3ComSys 1.3.6.1.4.1.43.2.13
OBJECT IDENTIFIER    

a3ComSysID 1.3.6.1.4.1.43.2.13.1
OBJECT IDENTIFIER    

a3ComChip 1.3.6.1.4.1.43.2.13.2
OBJECT IDENTIFIER    

a3ComMem 1.3.6.1.4.1.43.2.13.3
OBJECT IDENTIFIER    

a3ComBrd 1.3.6.1.4.1.43.2.13.4
OBJECT IDENTIFIER    

a3ComAudit 1.3.6.1.4.1.43.2.13.5
OBJECT IDENTIFIER    

a3ComTime 1.3.6.1.4.1.43.2.13.6
OBJECT IDENTIFIER    

a3ComAccCtl 1.3.6.1.4.1.43.2.13.7
OBJECT IDENTIFIER    

a3ComSysMisc 1.3.6.1.4.1.43.2.13.8
OBJECT IDENTIFIER    

a3ComFW 1.3.6.1.4.1.43.2.13.9
OBJECT IDENTIFIER    

a3ComBoot 1.3.6.1.4.1.43.2.13.10
OBJECT IDENTIFIER    

a3ComLastBoot 1.3.6.1.4.1.43.2.13.11
OBJECT IDENTIFIER    

a3ComFileMgmt 1.3.6.1.4.1.43.2.13.12
OBJECT IDENTIFIER    

a3ComFileList 1.3.6.1.4.1.43.2.13.12.9
OBJECT IDENTIFIER    

a3ComFmCksum 1.3.6.1.4.1.43.2.13.12.10
OBJECT IDENTIFIER    

a3ComFileInfo 1.3.6.1.4.1.43.2.13.12.11
OBJECT IDENTIFIER    

a3ComRecovery 1.3.6.1.4.1.43.2.13.13
OBJECT IDENTIFIER    

a3sysVersion 1.3.6.1.4.1.43.2.13.1.1
A text string containing general system information, including the package identifier and the system's software release number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

a3sysPlatformDescr 1.3.6.1.4.1.43.2.13.1.2
A text string describing the physical platform or chassis on which the system is running.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

a3sysPlatformID 1.3.6.1.4.1.43.2.13.1.3
An OID defining the system platform.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OBJECT IDENTIFIER  

a3sysCallerID 1.3.6.1.4.1.43.2.13.1.4
A text string defined by the user. This string can be used by a system running PPP as a unique identification of itself to its peer when communicating over a PPP link.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..31)  

a3sysChipTable 1.3.6.1.4.1.43.2.13.2.1
This table contains information about the chips that are used in the CPU board of the system.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    A3sysChipEntry

a3sysChipEntry 1.3.6.1.4.1.43.2.13.2.1.1
Each entry in this table contains information about one of the chips installed in the CPU module.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  A3sysChipEntry  

a3sysChipSlotIndex 1.3.6.1.4.1.43.2.13.2.1.1.1
This identifies a specific slot (and hence, a specific board). All the Chips described with this index are located on a single board.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

a3sysChipIndex 1.3.6.1.4.1.43.2.13.2.1.1.2
This identifies a specific chip on the board identified by a3sysChipSlotIndex.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

a3sysChipName 1.3.6.1.4.1.43.2.13.2.1.1.3
This provides a readable name for the chip.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

a3sysChipDescr 1.3.6.1.4.1.43.2.13.2.1.1.4
This provides general information about the chip, including its part number and revision number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

a3sysMemTable 1.3.6.1.4.1.43.2.13.3.1
This table contains information about the system's memory configurations.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    A3sysMemEntry

a3sysMemEntry 1.3.6.1.4.1.43.2.13.3.1.1
Each entry in this table contains information about a specific memory component. The information includes the memory type, its starting address and its size.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  A3sysMemEntry  

a3sysMemSlotIndex 1.3.6.1.4.1.43.2.13.3.1.1.1
This identifies the slot (and hence the board) that supports the memory elements identified by this entry in the table.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

a3sysMemIndex 1.3.6.1.4.1.43.2.13.3.1.1.2
The index into this table. Each memory component is identified by a unique value of this object. This is specific to the board identified by a3sysMemSlotIndex.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

a3sysMemType 1.3.6.1.4.1.43.2.13.3.1.1.3
This object identifies the type of the memory component.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(1), ram-instruction(2), ram-data(3), ram-shared(4), rom-fprom(5), rom-eeprom(6), ram-total(7)  

a3sysMemStartAdd 1.3.6.1.4.1.43.2.13.3.1.1.4
The starting address of the memory component.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

a3sysMemSize 1.3.6.1.4.1.43.2.13.3.1.1.5
The size of the memory component, in bytes.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

a3sysSlotNumber 1.3.6.1.4.1.43.2.13.4.1
The number of slots (empty or not) in the system
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

a3sysBrdTable 1.3.6.1.4.1.43.2.13.4.2
A table that contains information about the IO boards in this system.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    A3sysBrdEntry

a3sysBrdEntry 1.3.6.1.4.1.43.2.13.4.2.1
A list of information for each IO board in the system.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  A3sysBrdEntry  

a3sysSlotIndex 1.3.6.1.4.1.43.2.13.4.2.1.1
The slot number which this board occupies.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

a3sysBrdDescr 1.3.6.1.4.1.43.2.13.4.2.1.2
This contains general information about the Board, including the model type, the serial number, and manufacturing information.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

a3sysBrdPathCapacity 1.3.6.1.4.1.43.2.13.4.2.1.3
The number of physical ports supported by this board.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

a3sysBrdOID 1.3.6.1.4.1.43.2.13.4.2.1.4
The Object Identifier assigned to this Board.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OBJECT IDENTIFIER  

a3sysBrdReset 1.3.6.1.4.1.43.2.13.4.2.1.5
When this object is set to reset(2), the IO board in the slot specified by this instance identifier of this object is reset. If a GET request is sent for the value of this object, other(1) is returned.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER other(1), reset(2)  

a3sysBrdFwVers 1.3.6.1.4.1.43.2.13.4.2.1.6
This object returns the version of the firmware that is running on this network interface board. A list of all the OIDs assigned to 3Com router firmware can be ftp'd from ftp.3com.com.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OBJECT IDENTIFIER  

a3sysAuditTrailType 1.3.6.1.4.1.43.2.13.5.1
This object allows the user to determine the format of the time/date stamp that is included with each audit trail message the system generates. This only applies if there is a Network Control Server for the IBM PC/AT (NCS/AT) or Remote Boot and Configuration Services (RBCS) server on the attached network. Audit trail messages are generated by various network events and are displayed on the NCS or RBCS console.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER local(1), universal(2)  

a3sysLogServerAddress 1.3.6.1.4.1.43.2.13.5.2
The address of the NCS or the RBCS that serves as the log server for the system. The log server receives all of the system's audit trail messages.
Status: deprecated Access: read-write
OBJECT-TYPE    
  IpAddress  

a3sysDate 1.3.6.1.4.1.43.2.13.6.1
The current date and time as reflected by the system clock. The date is displayed via the User interface and Audit Trail Messages as yy/mm/dd hh:mm[:ss]. This same format must be used when setting the Date.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString  

a3sysDSTime 1.3.6.1.4.1.43.2.13.6.2
This parameter specifies the displacement, in minutes, from non-daylight savings time. The a3sysDSTime object, along with the a3sysTimeZone object, allows the system to support Universal time for network communications spanning different time zones.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER -120..120  

a3sysTimeZone 1.3.6.1.4.1.43.2.13.6.3
This object specifies the number of minutes displacement west of Greenwich the system's site is located. A negative number for this parameter indicates how many minutes displacement east of Greenwich the site is located. A positive number indicates the number of minutes west of Greenwich.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER -720..720  

a3sysRemoteAccess 1.3.6.1.4.1.43.2.13.7.1
This object determines whether another device can access this system via REMOTE
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

a3sysTelnetAccess 1.3.6.1.4.1.43.2.13.7.2
This object determines whether another device can access this system via TELNET
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

a3sysConsoleAccess 1.3.6.1.4.1.43.2.13.7.3
This object determines whether another device can access this system via the Console
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

a3sysSNMPAccess 1.3.6.1.4.1.43.2.13.7.4
This object determines whether another device can access this system via SNMP. Note, once SNMP access is disabled, the NMS will no longer be able to access this system via SNMP. If this is set to enabledTraps(1), the system allows SNMP access and will send traps when appropriate. If this is set to enabledNoTraps(2), the system allows SNMP access, but no traps will be sent. If this is set to disabledTraps, the system does not allow SNMP access, but will send traps when appropriate. If this is set to disabledNoTraps(4), the system does not allow SNMP access and does not send any traps.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enabledTraps(1), enabledNoTraps(2), disabledTraps(3), disabledNoTraps(4)  

a3sysSNMPCommTable 1.3.6.1.4.1.43.2.13.7.5
This table contains all the community strings known to the SNMP agent.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    A3sysSNMPCommEntry

a3sysSNMPCommEntry 1.3.6.1.4.1.43.2.13.7.5.1
Each entry in the table contains information about a single community string.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  A3sysSNMPCommEntry  

a3sysSNMPCommString 1.3.6.1.4.1.43.2.13.7.5.1.1
This identifies a specific community string.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(1..15)  

a3sysSNMPCommAccess 1.3.6.1.4.1.43.2.13.7.5.1.2
This identifies the level of access allowed for this community string.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER readOnly(1), readWrite(2)  

a3sysSNMPCommTrap 1.3.6.1.4.1.43.2.13.7.5.1.3
This specifies which traps get sent to the managers specified by this community string.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER genericOnly(1), authenOnly(2), allTraps(3), noTraps(4)  

a3sysSNMPCommStatus 1.3.6.1.4.1.43.2.13.7.5.1.4
This object is used to add and delete entries in this table. See the notes describing RowStatus at the beginning of this MIB.
Status: mandatory Access: read-write
OBJECT-TYPE    
  RowStatus  

a3sysSNMPMgrTable 1.3.6.1.4.1.43.2.13.7.6
This table contains the Managers that are allowed to use the community strings identified in a3sysSNMPCommTable. Each Manager is identified by its IP address.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    A3sysSNMPMgrEntry

a3sysSNMPMgrEntry 1.3.6.1.4.1.43.2.13.7.6.1
Each entry identifies a single Manager, community string pair.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  A3sysSNMPMgrEntry  

a3sysSNMPMgrCommString 1.3.6.1.4.1.43.2.13.7.6.1.1
This identifies a specific community string.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(1..15)  

a3sysSNMPMgrAddress 1.3.6.1.4.1.43.2.13.7.6.1.2
This identifies a single Management station that is allowed to use the community string associated with this entry. The set of all entries with same value of a3sysSNMPMgrCommString identifies all the Managers that are allowed to use that community string.
Status: mandatory Access: read-only
OBJECT-TYPE    
  IpAddress  

a3sysSNMPMgrMask 1.3.6.1.4.1.43.2.13.7.6.1.3
This object can be used to mask part of the IP address specified by a3sysSNMPMgrAddress. The use of this mask can then be used to identify a range of addresses that are allowed to use this community string.
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

a3sysSNMPMgrStatus 1.3.6.1.4.1.43.2.13.7.6.1.4
This object is used to add and delete entries in this table. See the notes describing RowStatus at the beginning of this MIB for specific instructions on how to do this.
Status: mandatory Access: read-write
OBJECT-TYPE    
  RowStatus  

a3sysTelnetMgrTable 1.3.6.1.4.1.43.2.13.7.7
This table contains the IP addresses that are allowed to use Telnet to access to the NetBuilder in the TelnetManager table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    A3sysTelnetMgrEntry

a3sysTelnetMgrEntry 1.3.6.1.4.1.43.2.13.7.7.1
Each entry identifies a single Manager, community string pair.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  A3sysTelnetMgrEntry  

a3sysTelnetMgrAddress 1.3.6.1.4.1.43.2.13.7.7.1.1
This identifies a single Management station that is allowed to use the Telnet to manage the NetBuilder. Maximally, six (6) IP addresses can be configured in each NB.
Status: mandatory Access: read-only
OBJECT-TYPE    
  IpAddress  

a3sysTelnetMgrStatus 1.3.6.1.4.1.43.2.13.7.7.1.2
This object is used to add and delete entries in this table. See the notes describing RowStatus at the beginning of this MIB for specific instructions on how to do this.
Status: mandatory Access: read-write
OBJECT-TYPE    
  RowStatus  

a3sysPasswordTable 1.3.6.1.4.1.43.2.13.7.8
This table contains the system's passwords.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    A3sysPasswordEntry

a3sysPasswordEntry 1.3.6.1.4.1.43.2.13.7.8.1
Each entry identifies a single system password.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  A3sysPasswordEntry  

a3sysPwStatus 1.3.6.1.4.1.43.2.13.7.8.1.1
User Status. `invalid' is used to indicate this user is no longer allowed to access this device, and the table entry may subsequently be re-used. Note that the Status of default Users cannot be set to invalid.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

a3sysUserName 1.3.6.1.4.1.43.2.13.7.8.1.2
An ASCII string for the User Name. Empty strings are not allowed. The index column for the User Table. There are two default users defined, 'root' and 'user'.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(1..10)  

a3sysUserLevel 1.3.6.1.4.1.43.2.13.7.8.1.3
User Access Level defining the scope of management allowed for this user. Note that the access level of default Users cannot be changed.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER monitor(1), secureMonitor(2), manager(3), specialist(4), security(5)  

a3sysOldPassword 1.3.6.1.4.1.43.2.13.7.8.1.4
The current password.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

a3sysNewPassword 1.3.6.1.4.1.43.2.13.7.8.1.5
The new password.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString  

a3sysSnmpPasswordCtl 1.3.6.1.4.1.43.2.13.7.9
This object indicates whether this system's passwords can be changed via snmp.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

a3sysNetMapTime 1.3.6.1.4.1.43.2.13.8.1
The number of seconds between broadcasts of the system's address on the attached network. This only applies to 3Com's NETMap protocol. If this object is set to 0, the broadcasting of the system's address is disabled.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..120  

a3sysUIBinary 1.3.6.1.4.1.43.2.13.8.2
If on, the system is allowed to negotiate for binary transmission when a Telnet connection is made.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER on(1), off(2)  

a3sysChangeTimestamp 1.3.6.1.4.1.43.2.13.8.3
This object contains the value of sysUpTime when the most recent change was made to this system, either via the Console, TELNET, or through SNMP.
Status: mandatory Access: read-only
OBJECT-TYPE    
  TimeTicks  

a3sysCpuUtil 1.3.6.1.4.1.43.2.13.8.4
This object provides a measure of the current utilization of the CPU on this system.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..100  

a3sysCpuBrdMacAddr 1.3.6.1.4.1.43.2.13.8.5
The system's MAC address. For those devices whose CPU boards contain a MAC address, this object provides the value of that address (NB2's). For those devices whose CPU boards don't contain a MAC address (NB1's), this provides the MAC address of the first interface.
Status: mandatory Access: read-only
OBJECT-TYPE    
  MacAddress  

a3sysExpMacAddr 1.3.6.1.4.1.43.2.13.8.6
This identifies the MAC address to which the @m symbol is expanded when doing file copies.
Status: mandatory Access: read-only
OBJECT-TYPE    
  MacAddress  

a3sysVportTimestamp 1.3.6.1.4.1.43.2.13.8.7
This specifies the value of sysUpTime when the last virtual port was added or deleted. This object should be used to determine if and when the set of virtual ports supported by this system has changed.
Status: mandatory Access: read-only
OBJECT-TYPE    
  TimeTicks  

a3sysDefDrive 1.3.6.1.4.1.43.2.13.8.8
This object identifies the current default drive for this system.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER driveA(1), driveB(2)  

a3sysDefDriveType 1.3.6.1.4.1.43.2.13.8.9
This object identifies the current default drive type for this system.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER floppy(1), flash(2), unknown(3), noDrive(4)  

a3sysDriveStatus 1.3.6.1.4.1.43.2.13.8.10
This object identifies which disk drives are supported by this system. noDrives(1) means no disk drives are supported. driveA means only drive A is supported. driveB means only drive B is supported, while driveAB(4) means both drives A and B are supported.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noDrives(1), driveA(2), driveB(3), driveAB(4)  

a3sysBogusDhcpSvr 1.3.6.1.4.1.43.2.13.8.11
This object has the IP address of the last seen bogus DHCP or BOOTP server.
Status: mandatory Access: read-only
OBJECT-TYPE    
  IpAddress  

a3sysNb2EepromVers 1.3.6.1.4.1.43.2.13.8.12
This object returns the version number of the EEPROM on a NetBuilderII. Various features are dependent on having the correct version of EEPROM resident on the NetBuilderII.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

a3sysX25Conns 1.3.6.1.4.1.43.2.13.8.13
This object returns the number of active X25 connections currently maintained by the NetBuilder.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

a3sysFwSerBaudCons 1.3.6.1.4.1.43.2.13.9.1
This object sets the baud rate for the console port, which is located on the CEC module's connector/LEDC panel.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER unknown(1), bps110(2), bps300(3), bps600(4), bps1200(5), bps2400(6), bps4800(7), bps9600(8), bps19200(9), bps38400(10), bps57600(11)  

a3sysFwSerBaudAux 1.3.6.1.4.1.43.2.13.9.2
This object sets the baud rate for the auxiliary port, which is located on the CEC module's connector/LEDC panel.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER unknown(1), bps110(2), bps300(3), bps600(4), bps1200(5), bps2400(6), bps4800(7), bps9600(8), bps19200(9)  

a3sysFwSelfTest 1.3.6.1.4.1.43.2.13.9.3
This parameter determines how the system handles self tests when the system is powered on or reset. The system can be configured to skip its self tests, run self tests once, or run self tests continuously (loop).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER skip(1), testOnce(2), other(3), loop(4)  

a3sysReBoot 1.3.6.1.4.1.43.2.13.10.1
This object can be used to reboot the system. If this object is set to stdReboot(2), the system's action is determined by the value of a3sysStartUpAction. If that object has the value monitor(1), the system will go into monitor mode. If that object has the value userListOnce(2) or userListForever(3), the system will attempt to reboot from the sources identified by the User Boot List. If this object is read, the value, other (1), will be returned.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER other(1), stdReboot(2)  

a3sysTestBootTime 1.3.6.1.4.1.43.2.13.10.2
The Test Boot Time indicates the number of seconds after a test reboot the system will automatically reboot. Upon reboot, the system will start up a timer initialized to the value of this object. The object a3sysTestRecoveryTimer contains the real time value of this timer. The timer will automatically start counting down after the system comes up. If this timer expires, the system will automatically reboot using the Primary Boot Source. To cancel the timer, the object a3sysTestRecoveryTimer must be set to zero. This provides a recovery mechanism for a system under test that loses management connectivity.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

a3sysStartUpAction 1.3.6.1.4.1.43.2.13.10.3
This parameter determines the boot source when the system is powered on or reset. If monitor (1) is chosen, the system enters monitor mode immediately. If userListOnce (2) is chosen, the system attempts to boot from primary and secondary sources defined by the User Boot List. (Specifics about the use of the secondary boot source are provided by a3sysBootSources.) This list may identify network boot sources or local floppy sources, or both. If userListForever (3) is chosen, the system will keep trying the sources listed in the User Boot List until one of them is successful. If local(4) is chosen, the system will boot from the local floppy. The name of the file used is identified by the value of a3sysUblFileName for the Primary Boot Source.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER monitor(1), userListOnce(2), userListForever(3), local(4)  

a3sysTestRecoveryTimer 1.3.6.1.4.1.43.2.13.10.4
This object contains the real time value of the Test Recovery Timer. When the system is performing a 'test boot' (ie, a boot when a3sysBootSources equals testWithPrimaryBackup (3)), the system will start a countdown timer initialized to the value of a3sysBootTime. If this timer is allowed to count down to zero, the system will reboot, this time using the primary boot source instead of the test boot source. If the timer is disabled, however, before it counts down (the timer is disabled by setting the value of this object to zero), the system won't reboot and will continue to run the test boot source's software. This timer is part of a comprehensive software update strategy. See the relevant 3Com manuals for more details.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

a3sysDirectedReBoots 1.3.6.1.4.1.43.2.13.10.5
This is a counter that tracks the number of times the system has completed successfully a boot, no matter how the boot was initiated (power-on, front-panel-button reset, command line, or exception).
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

a3sysExceptionReBoots 1.3.6.1.4.1.43.2.13.10.6
This is a counter that tracks the number of times the system has crashed and a reboot sequence is begun by the exception handler. Note, some type of crashes are not able to update this counter due to various hardware lockups. Also note, this counter will be incremented when a user resets the system from the command line (RS). This will not be incremented, however, when the user reboots the system from the command line (RB).
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

a3sysBootDump 1.3.6.1.4.1.43.2.13.10.7
This determines whether or not a memory dump is performed if the system fails due to a software problem. If noDump (1) is selected, the system will not attempt to perform a memory dump. If monitor (2) is selected, the system goes directly into monitor mode and waits for further commands. If localDevice (3) is selected, the system dumps its memory to the local storage device. Since the memory dump will require several floppy disks, the system will prompt the user via the User Interface to change disks. If userList (4) is selected, the system will upload its memory to the source specified in the User Boot List. Only the NetBuilder Remote Office and NetBuilder II support the network(5) option. If this is set, the parameters in entry four (dump) of a3sysUserBootListTable identify the destination.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER noDump(1), monitor(2), localDevice(3), userList(4), network(5)  

a3sysBootSources 1.3.6.1.4.1.43.2.13.10.8
This parameter is used to specify how the entries in this table are used. If this object is set to primary(1), the system will use only the primary boot source when rebooting. (note, this is the entry where a3sysUblSource = primary(1)). If this object is set to primaryAndSecondary(2), the system will attempt to boot first from the primary boot source, and, if that fails (after a3sysUblMaxRetries attemps), the system will try the secondary boot source. If this object has the value testWithPrimaryBackup(3), the system, when rebooting, will perform a test boot using the 'test' boot source. Note, the NetBuilder Remote Office and NetBuilder II use entry 3 in a3sysUserBootListTable as the 'test' boot source (a3sysUblSource = test(3)), while other 3Com routers (NetBuilder Remote, NetBuilder Remote Control, NetBuilder Local, and NetBuilder Remote Access) don't support all 4 rows in a3sysUserBootListTable, and simply use the secondary boot source (a3sysUblSource = secondary(2)) to identify the 'test' boot source. After booting from the 'test' boot source, if the Test Recovery Timer (a3sysTestRecoveryTimer) is allowed to count down to zero, the system will reboot using the primary boot source. (see the reference guide for details about test booting). When in this mode, to prevent the system from rebooting using the primary boot source, the Test Recovery Timer (a3sysTestRecoveryTimer) must be set to zero. Note, this object cannot be set to testWithPrimaryBackup(3) explicitly. Instead, by setting a3sysTestBootTimer to a non-zero value, the system will automatically go into 'Test Boot' mode and this object will be given the value testWithPrimaryBackup(3). If this object has the value secondary(4), the system will use only the secondary boot source when rebooting.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER primary(1), primaryAndSecondary(2), testWithPrimaryBackup(3), secondary(4)  

a3sysUserBootListTable 1.3.6.1.4.1.43.2.13.10.9
This table defines a list of boot sources (and for the NetBuilder Remote Office -- memory dump destinations). There are two other parameters that dictate how the contents of this table are used. These parameters are represented by a3sysStartUpAction and a3sysBootSources. a3sysStartUpAction specifies what this system does when it first comes up. If a3sysStartUpAction is set to userListOnce (2), the system will make a single attempt to use the entries in this table to identify how it should boot. If a3sysStartUpAction is set to userListForever (3), the system will make repeated attempts at using the entries in this table. If a3sysStartUpAction indicates that the system is to use this table, the order in which the entries are used is dictated by a3sysBootSources. If a3sysBootSources has the value primary (1), the system will attempt to boot only from the source identified by entry 1 in this table. If a3sysBootSources has the value primaryAndSecondary(2), the system will attempt to boot first from the source identified by entry 1, and, if that source fails, the system will try the source identified by entry 2 (the secondary source). If a3sysBootSources has the value testWithPrimaryBackup(3), the system will perform a test boot using the test boot source. Note, for the NetBuilder Remote Office, this is the third entry (test) in this table. For the NetBuilder II and the NetBuilder I family( NetBuilder Local, NetBuilder Remote, NetBuilder RemoteAccess, and NetBuilder RemoteControl), the test boot source is identified by entry 2 (secondary) in this table. If the test boot source fails (see the Reference Guide for more details on test booting), the system will revert back to the source identified by entry 1 (primary) in this table. The NetBuilder Remote Office supports a fourth entry in this table, which identifies where over the network memory is to be dumped in the case of a system crash. Note, the destination device (a3sysUblDevice) must be set to network (3), in this case. Also note that many of the columns in this row will be irrelevant and won't affect where the memory gets dumped. Note, all entries in this table apply only to future boots. They don't necessarily provide information about previous boots.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    A3sysUserBootListEntry

a3sysUserBootListEntry 1.3.6.1.4.1.43.2.13.10.9.1
Each entry in this table contains a single boot source.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  A3sysUserBootListEntry  

a3sysUblSource 1.3.6.1.4.1.43.2.13.10.9.1.1
This identifies the entry number in this table. Currently, the table is limited to two entries. The first entry is labelled primary(1), the next has the label secondary(2). The NetBuilder RemoteOffice and NetBuilder II (as of sw version 8.0) supports two additional entries. Entry three (test) identifies a separate boot block which is used when doing a test boot. Entry four (dump) identifies where memory is to be dumped. Note, only a subset of the columns in this entry are relevant. Specifically, a3sysUblDevice must have the value network(3) (ie, memory dumps are preformed only over the network by the NBRO).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER primary(1), secondary(2), test(3), dump(4)  

a3sysUblDevice 1.3.6.1.4.1.43.2.13.10.9.1.2
This object identifies the source from which the system attempts to boot. If this object is set to localMediaA(1), the system will attempt to boot from drive A of the local storage media (A is the flash drive for those systems with both flash and floppy drives), using the filename identified by a3sysUblFileName. If this is set to localMediaB(2), the system will boot from drive B. If this object is set to network (3), the system will attempt to boot from a BOOTP/TFTP server attached to the network. The network interface that is used in the booting is identified by both a3sysUblSlot and a3sysUblInterface. The name of the boot file on the remote system is identified by a3sysUblFileName. monitor(4) is no longer supported. If this object has the value other(5), nothing has been specified.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER localMediaA(1), localMediaB(2), network(3), monitor(4), other(5), auto(6)  

a3sysUblFileName 1.3.6.1.4.1.43.2.13.10.9.1.3
This specifies the path and name of the boot file. For example, to specify the file boot.29k in the root directory, this object should have the value 'boot.29k'
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString  

a3sysUblNetFile 1.3.6.1.4.1.43.2.13.10.9.1.4
This object has been deprecated. (use a3sysUblFileName regardless of whether it's local or remote).
Status: deprecated Access: read-write
OBJECT-TYPE    
  DisplayString  

a3sysUblSlot 1.3.6.1.4.1.43.2.13.10.9.1.5
This specifies the physical slot where the IO module from which the system will be booting is installed. This only applies when a3sysUblDevice is set to network(2)
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

a3sysUblInterface 1.3.6.1.4.1.43.2.13.10.9.1.6
This specifies the physical port on the IO module (installed in the slot identified by a3sysUblSlot) that the system will be booting from. This only applies when a3sysUblDevice is set to network(2). If there is only one connector in the module, this object should have the value: interfaceA(2).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER unknown(1), interfaceA(2), interfaceB(3)  

a3sysUblMaxRetries 1.3.6.1.4.1.43.2.13.10.9.1.7
This object determines the number of times the system will try to boot from the source identified by this table entry before going to the next entry.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..255  

a3sysUblConfigFileDevice 1.3.6.1.4.1.43.2.13.10.9.1.8
This specifies the device used to access the configuration files needed by this system. If this object has the value bootDevice(1), the system will look for its configuration files on the same device as its boot files. This device is specified by a3sysUblDevice. If this object has the value network(3), the system will look for its configuration files on the device specified by a3sysUblConfigIpAddr. If this object has the value local(2), the system will look for its configuration files on the local storage media. If this object has the value other(4), nothing has been specified. In all the cases listed above, the path for the configuration files is specified by a3sysUblConfigFilePath.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER bootDevice(1), local(2), network(3), other(4)  

a3sysUblConfigFilePath 1.3.6.1.4.1.43.2.13.10.9.1.9
This object specifies the path to the configuration files needed by this system.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString  

a3sysUblConfigProt 1.3.6.1.4.1.43.2.13.10.9.1.10
This object specifies the protocol to use to get the configuration files if they are stored across the network. Note, this applies only if the value of a3sysUblConfigFileDevice is network(3) or bootDevice(1). If a3sysUblConfigFileDevice has the value bootDevice(1), then the corresponding instance of a3sysUblDevice must be network(2) for this object to have relevance. This object has been changed to read-only in 9.0. The only valid value for this object is ftp(2).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER fap(1), ftp(2), other(3)  

a3sysUblConfigUserName 1.3.6.1.4.1.43.2.13.10.9.1.11
This object indicates the Username to be used by the file service protocol identified the corresponding instance of a3sysUblConfigProt.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..20)  

a3sysUblConfigPassword 1.3.6.1.4.1.43.2.13.10.9.1.12
This specifies the Password to be used by the file service protocol identified by the corresponding instance of a3sysUblConfigProt. Note, for reasons of security, the value of this object will be hidden. A string of 4 stars (*) will be returned in response to any GET or GETNEXT request.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..20)  

a3sysUblConfigAcct 1.3.6.1.4.1.43.2.13.10.9.1.13
This specifies the Account Name used by the file service protocol. Note, for reasons of security, the value of this object will be hidden. A string of 4 stars (*) will be returned in response to any GET or GETNEXT request.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..30)  

a3sysUblMacAddress 1.3.6.1.4.1.43.2.13.10.9.1.14
The MAC address to be used for booting over the network. This can be configured to use either the MAC address assigned to the CPU module or the MAC address assigned to the I/O module over which the boot is being performed.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER cpu-module(1), io-module(2), other(3)  

a3sysUblCanonicalFlag 1.3.6.1.4.1.43.2.13.10.9.1.15
This controls the format of addresses within ARP packets sent by this system.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER other(1), canonical(2), nonCanonical(3)  

a3sysUblRemoteProt 1.3.6.1.4.1.43.2.13.10.9.1.16
This object specifies which serial link protocol to use if a3sysUblSlot identifies a slot with a High Speed Serial board. If this is set to auto (4), the system will try all supported protocols until the serial line is active. If there is a different kind of board in that slot, the value of this object is ignored.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), ppp(2), frameRelay(3), auto(4)  

a3sysUblBaudRate 1.3.6.1.4.1.43.2.13.10.9.1.17
This object specifies the serial line or Token Ring baud rate. For all other types of ports, this object will be ignored.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER unknown(1), bps9600(2), kbps19(3), kbps38(4), kbps56(5), kbps64(6), kbps128(7), kbps256(8), kbps448(9), kbps1536(10), kbps2048(11), mbps4(12), mbps16(13)  

a3sysUblClockSource 1.3.6.1.4.1.43.2.13.10.9.1.18
This specifies whether to use an internal or external clock source. This applies only to High Speed Serial ports.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER internal(1), external(2), unknown(3)  

a3sysUblConnectorType 1.3.6.1.4.1.43.2.13.10.9.1.19
This object specifies the serial line connector type.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER unknown(1), rs232(2), v35(3)  

a3sysUblWanAddress 1.3.6.1.4.1.43.2.13.10.9.1.20
This specifies a string to initiate a WAN connection. The specified string required is interface and protocol specific. The maximum string length is 80 bytes. Note, this applies only to High Speed Serial ports.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..80)  

a3sysUblClientIpAddr 1.3.6.1.4.1.43.2.13.10.9.1.21
The IP Address of this system used in packets when booting over the network.
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

a3sysUblServerIpAddr 1.3.6.1.4.1.43.2.13.10.9.1.22
The IP address of the Boot Server.
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

a3sysUblGwIpAddr 1.3.6.1.4.1.43.2.13.10.9.1.23
The IP address of the gateway that will forward packets to the Boot Server.
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

a3sysUblConfigFileIpAddr 1.3.6.1.4.1.43.2.13.10.9.1.24
The IP address of the configuration files Server, if needed.
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

a3sysUblIpMask 1.3.6.1.4.1.43.2.13.10.9.1.25
The mask to be applied to the addresses specified above.
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

a3sysUblAddressDiscovery 1.3.6.1.4.1.43.2.13.10.9.1.26
This specifies the address discovery protocol to use for booting from the network. If configAddr(3) is specified, then the configured addresses are used. If nothing has been specified, other(1) is returned.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER other(1), bootp(2), configAddr(3), bootpRarp(4), rarp(5), rarpBootp(6)  

a3sysUblPassword 1.3.6.1.4.1.43.2.13.10.9.1.27
This is needed when booting over a port that uses a protocol that requires a password, e.g, PPP.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..5)  

a3sysIioBootTable 1.3.6.1.4.1.43.2.13.10.10
This table specifies where each IIO card obtains its boot image.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    A3sysIioBootEntry

a3sysIioBootEntry 1.3.6.1.4.1.43.2.13.10.10.1
Each entry in this table corresponds to a specific slot in the NetBuilder chassis. If an IIO board is in that slot, that entry determines where that IIO board obtains its boot image.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  A3sysIioBootEntry  

a3sysIioBootSlot 1.3.6.1.4.1.43.2.13.10.10.1.1
This object specifies the slot into which the IIO board corresponding to this entry is placed.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

a3sysIioBootFileName 1.3.6.1.4.1.43.2.13.10.10.1.2
This object specifies the path and name of the IIO board's boot image. If the value of this object specifies a drive, the path is assumed to start from root. If the value of this object does not specify a drive number, this object specifies the path starting from the config file directory specified by a3sysUblConfigFilePath. In this case, the value of this object must not begin with a slash '/'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString  

a3sysIioBootState 1.3.6.1.4.1.43.2.13.10.10.1.3
This object provides the current state of the IIO card installed in this slot. If there is no IIO card in the slot, this object will have the value empty(1). If the card is up and running, this object will have the value up(2). If the card is booting, this object will have the value booting(3). If the boot has failed, and the card is in the process of recovering from the failed boot, this object will have the value recovering(4). If in the process of recovering, the IIO dumps its image, this object will have the value dumping(5). Note that this is simply a sub-state within the more general recovering state. If after recovering, the IIO card goes into a halted state, this object will have the value halted(6). If the IIO card gets into an unrecoverable state, this object will have the value error(8).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER empty(1), up(2), booting(3), recovering(4), dumping(5), halted(6), selfTestFail(7), error(8)  

a3sysIioBootTime 1.3.6.1.4.1.43.2.13.10.10.1.4
The value of sysUpTime when the IIO board last went into the UP state.
Status: mandatory Access: read-only
OBJECT-TYPE    
  TimeTicks  

a3sysIioBootImage 1.3.6.1.4.1.43.2.13.10.10.1.5
The OID assigned to this version of Iio Software.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OBJECT IDENTIFIER  

a3sysLastBootSource 1.3.6.1.4.1.43.2.13.11.1
This object identifies the source from which the system last booted. The specifics of the boot source can be found from the corresponding User Boot List entry.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER primary(1), secondary(2), monitor(3), test(4)  

a3sysLastBootError 1.3.6.1.4.1.43.2.13.11.2
This object identifies the reason for the most recent boot failure.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER none(1), unknownLocalAddress(2), unknownServerAddress(3), noServerResponse(4), fileTransferFailed(5), imageNotFound(6), imageInvalid(7)  

a3sysLastBootDate 1.3.6.1.4.1.43.2.13.11.3
The date and time as reflected by the system clock at the time the system last rebooted. The date has the format yy/mm/dd hh:mm[:ss].
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

a3sysLbConfigFileIpAddr 1.3.6.1.4.1.43.2.13.11.4
The IP address of the configuration file server used during the most recent boot. Note, even if the configuration files were obtained locally, an address may have been configured. This is the address used when performing all ftp PUT and GET operations.
Status: mandatory Access: read-only
OBJECT-TYPE    
  IpAddress  

a3sysLbGwIpAddr 1.3.6.1.4.1.43.2.13.11.5
The IP address of the gateway that was used to forward packets to the boot server or configuration file server during the last boot.
Status: mandatory Access: read-only
OBJECT-TYPE    
  IpAddress  

a3sysLbIpMask 1.3.6.1.4.1.43.2.13.11.6
The IP subnet mask configured during the last boot.
Status: mandatory Access: read-only
OBJECT-TYPE    
  IpAddress  

a3sysLbConfigDevice 1.3.6.1.4.1.43.2.13.11.7
The config file device used during the last boot.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER bootDevice(1), local(2), network(3), other(4)  

a3sysLbConfigFilePath 1.3.6.1.4.1.43.2.13.11.8
The config file path used during the last boot.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

a3sysLbConfigUserName 1.3.6.1.4.1.43.2.13.11.9
If the config files were obtained from a file server during the last boot, this object contains the user name used during the ftp transfer of those files.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..20)  

a3sysFmOperation 1.3.6.1.4.1.43.2.13.12.1
This object is used to initiate a file management operation. When set to copy(2), the system will get the file from the Source device (identified by a3sysFmSourceIpAddr and a3sysFmSourceFile) and copy it to the Target device (identified by a3sysFmTargetIpAddr and a3sysFmTargetFile). Note, both the Source and Target devices cannot be remote systems. At least one must be the local system. All information about the file and the server is taken from the values of the other objects in this group. To avoid unnecessary errors, the relevant objects in this group should be examined and their values validated before setting this object to copy(2). Currently, the do(3) enumeration is not supported. If this object is set to delete(4), the system will delete a single file on the local storage device. The file is identified by a3sysFmTargetFile. For software release 6.2, the rename(5) enumeration is not supported. This is supported, however, by release 7.0. If this object is directory(6), the system will list the file in the directory identified by a3sysFmTargetFile. The resulting list can be obtained by examining a3sysDfTable. For software release 6.2, enumerations 7 through 9 are not supported. Enumeration 7 and 9 are supported by release 7.0. If this object is set to abortCopy(10), the system will abort any file copy process in progress. If this object is set to makeDir(11), the system will create a directory off the root directory. The name of this directory is specified by a3sysFmTargetFile. If this object is set to rmDir(12), the system will remove the directory identified by a3sysFmTargetFile. If this object is set to getFileInfo(13), the system will retrieve information about the file identified by a3sysFmTargetFile and return that information via the a3ComFileInfo group. (ie, examine the contents of that group after this object is set to getFileInfo(13)). If this object is set to ftpGet(14), the system will retrieve the file identified by a3sysFmSourceFile. It will retrieve the file from the device from which the configuration files were originally obtained. That device can be identified by a3sysLbConfigFileIpAddr. Note, even if the config files were obtained locally, a valid IP address may have been configured. That is the device used for future ftp operations. If a path is not specified, the file will be taken from the configuration file directory. The config file directory cay be identified by a3sysLbConfigFilePath. If a relative path is specified, and the configuration files were originally obtained (ie, at last boot) from the network, the path is interpreted relative to the configuration file directory. If a relative path is specified and the configuration files were originally obtained locally, the path is interpreted relative to the login directory. Absolute paths are allowed. Once obtained, the file will be placed in the location identified by a3sysFmTargetFile. Note, this must be on one of the local storage devices. If this object is set to ftpPut(15), the system will place the file identified by a3sysFmSourceFile and place it on the device from which the config files were obtained originally. The path and filename of the placed file is identified by a3sysFmTargetFile. As with ftpGet(14), if a relative path is specified, and the configuration files were originally obtained from the network, the path is interpreted relative to the configuration file directory. If a relative path is specified and the configuration files were originally obtained locally, the path is interpreted relative to the login directory. Absolut paths are allowed. Note, the source file must be on one of the local storage devices. If this object is read, other(1) will be returned.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER other(1), copy(2), do(3), delete(4), rename(5), directory(6), format(7), copySystem(8), checksum(9), abortCopy(10), makeDir(11), rmDir(12), getFileInfo(13), ftpGet(14), ftpPut(15), cleanFlash(16)  

a3sysFmSourceIpAddr 1.3.6.1.4.1.43.2.13.12.2
This object specifies the IP address of the Source device from which files are obtained. If this is set to zero's, the local storage device is assumed.
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

a3sysFmSourceFile 1.3.6.1.4.1.43.2.13.12.3
This specifies the path and name of a source file. For example, if the action specified by a3sysFmOperation is copy(2) or rename(5), this identifies the path and name of the file to be copied or renamed. If there is no leading path string, the source file will be accessed from the root directory. For devices with multiple disk drives, the drive will be identified by appending a prefix to the path. For example, a:/path/name
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString  

a3sysFmTargetIpAddr 1.3.6.1.4.1.43.2.13.12.4
This object specifies the IP address of the target device to which files are copied, renamed, etc.
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

a3sysFmTargetFile 1.3.6.1.4.1.43.2.13.12.5
This specifies the path and name of the target file on the target system. (The filename may contain the string '@M' which will be expanded to the system MAC address. Alternatively, the filename may contain the string '@m' which will be expanded to the last six characters of the system MAC address. This provides a mechanism for a remote system to generate system specific filenames automatically.) If there is no leading path string, the file will be accessed from the root directory. For devices with multiple disk drives, the drive will be identified by appending a prefix to the path. For example, a:/path/name. If the action specified by a3sysFmOperation is copy(2), this identifies where, on the target system (identified by a3sysFmTargetIpAddr) the file is to be placed and the name to give it. If the action specified by a3sysFmOperation is delete(4), this identifies the path and name of the local file which is to be deleted. If the action specified by a3sysFmOperation is directory(6), this identifies the full path of the directory that is to be listed.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString  

a3sysFmStatus 1.3.6.1.4.1.43.2.13.12.6
This identifies the current status of the file management operation. This applies to the following operations: copy(2), and directory(6). If there is an operation in progress, this object will have the value inProgress(2). Otherwise inactive(1) will be returned.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER inactive(1), inProgress(2)  

a3sysFmTimeStamp 1.3.6.1.4.1.43.2.13.12.7
This specifies the value of sysUpTime when the most recent file management operation was initiated.
Status: mandatory Access: read-only
OBJECT-TYPE    
  TimeTicks  

a3sysFmError 1.3.6.1.4.1.43.2.13.12.8
This object identifies the results of the most recent attempt at a file operation. If no file operations have been attempted since the system was initialized, this object will have the value none(1). If the last operation was successful, this object will have the value successful(2). If the last operation could not be initiated because there was another operation in progress, this object will have the value inProgress (3). If the source IP Address is invalid, this object will have the value badSourceAddr(4). If the source file name contains a syntax error, this object will have the value badSourceFile(5). If the target IP Address is invalid, this object will have the value badTargetAddr(6). If there was a syntax error in the identification of the target file (a3sysFmTargetFile), this object will have the value badTargetFile(7). If the remote server does not respond, this object will have the value noResponse(8). If either the source file or target file could not be found, this object will have the value noFile(9). If there is no space on the destination system this object will have the value noSpace(10). If the destination file location is write protected, this object will have the value noPermission(11). If there is an error encountered while writing the file to its destination, this object will have the value writeError(12). If the transfer took too much time and exceeded its limits, this object will have the value timeout(13). If the verify operation failed, this object will have the value badChecksum(14). If the operation requested is not supported by this platform or software version, this object will have the value badOperation(15). If the opereration was aborted by a user, this object will have the value aborted(16). If no drive is indicated in either the source or target files, and the default drive is not local (this will be the case when the system obtained its config files over the network the last time it booted), this object will have the value badDefaultDrv(18). This object will have the value other(17) if an error occured that is not listed here.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER none(1), successful(2), inProgress(3), badSourceAddr(4), badSourceFile(5), badTargetAddr(6), badTargetFile(7), noResponse(8), noFile(9), noSpace(10), noPermission(11), writeError(12), timeout(13), badChecksum(14), badOperation(15), aborted(16), other(17), badDefaultDrv(18), badTargetPort(19)  

a3sysDfTime 1.3.6.1.4.1.43.2.13.12.9.1
This object specifies the value of sysUpTime when the list of files on the system disk was last updated. This list is updated by setting a3sysFmOperation to directory(6).
Status: mandatory Access: read-only
OBJECT-TYPE    
  TimeTicks  

a3sysDfPath 1.3.6.1.4.1.43.2.13.12.9.2
This object identifies the directory path under which the files listed in a3sysDfTable were obtained. Where necessary, this object also identifies the disk drive where the files are stored.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

a3sysDfTable 1.3.6.1.4.1.43.2.13.12.9.3
This table contains a listing of all the files in a specific directory on one of the systems disks. The directory and disk are identified by a3sysDfPath. Each entry in this table contains information about a single file.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    A3sysDfEntry

a3sysDfEntry 1.3.6.1.4.1.43.2.13.12.9.3.1
Each entry in this table describes a single disk file.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  A3sysDfEntry  

a3sysDfName 1.3.6.1.4.1.43.2.13.12.9.3.1.1
This contains the name of a single file on the disk.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

a3sysDfDir 1.3.6.1.4.1.43.2.13.12.9.3.1.2
This specifies whether the file identified by the corresponding instance of a3sysDfName is a regular file or a directory.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER file(1), directory(2)  

a3ComDfTotalSpace 1.3.6.1.4.1.43.2.13.12.9.4
The total size (in bytes) of the drive identified by a3sysDfPath
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

a3ComDfAvailableSpace 1.3.6.1.4.1.43.2.13.12.9.5
The available space (in bytes) of the drive identified by a3sysDfPath.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

a3sysFmCksum 1.3.6.1.4.1.43.2.13.12.10.1
This object specifies the results of a ccitt crc16 cyclic redundancy check performed on the file specified by a3sysTargetFile. The value of a3sysTargetFile at the time this crc was performed is provided by a3sysFmCksumFile.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

a3sysFmCksumFile 1.3.6.1.4.1.43.2.13.12.10.2
This object specifies the file upon which the last ccitt crc16 cyclic redundancy check was performed. The results of this operation are specified by a3sysFmCksum.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

a3sysFmCksumTime 1.3.6.1.4.1.43.2.13.12.10.3
This object specifies the value of sysUpTime when the last ccitt crc16 cyclic redundancy check was performed. The results of this operation are specified by a3sysFmCksum.
Status: mandatory Access: read-only
OBJECT-TYPE    
  TimeTicks  

a3sysFiName 1.3.6.1.4.1.43.2.13.12.11.1
This object specifies the name of the file to which the rest of this group refers.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

a3sysFiDate 1.3.6.1.4.1.43.2.13.12.11.2
This object specifies the date when the file (specified by a3sysFiName was last updated. The format of the date is yy/mm/dd hh:min:sec.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

a3sysFiTimeStamp 1.3.6.1.4.1.43.2.13.12.11.3
This object specifies the value of sysUpTime when this group of objects was last updated. To update this group, set a3sysFmTargetFile to the desired file, and set a3sysFmOperation to getFileInfo(13).
Status: mandatory Access: read-only
OBJECT-TYPE    
  TimeTicks  

a3sysFmSize 1.3.6.1.4.1.43.2.13.12.11.4
This object specifies the size of the file (specified by a3sysFiName) in bytes.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

a3sysIioRecoveryTable 1.3.6.1.4.1.43.2.13.13.1
This table specifies the recovery procedure for each Intelligent IO board in the system. This also specifies the recovery procedure for the CEC card. Note, the eeprom version must be 5 or greater for this table to operate properly.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    A3sysIioRecoveryEntry

a3sysIioRecoveryEntry 1.3.6.1.4.1.43.2.13.13.1.1
Each entry in this table corresponds to a specific slot in the NetBuilder chassis. If an IIO board is in that slot, that entry determines the action taken by that IIO board in the event it crashes. There is also an entry in this table for the CEC board.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  A3sysIioRecoveryEntry  

a3sysIioRecoverySlot 1.3.6.1.4.1.43.2.13.13.1.1.1
This object specifies the slot into which the IIO (or CEC) board corresponding to this entry is placed.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..8  

a3sysIioRecoveryProcedure 1.3.6.1.4.1.43.2.13.13.1.1.2
The value of this object determines the action taken if the IIO (or CEC) crashes. If the value of this object is selectiveDumpAndReboot (5), the value of a3sysIioRecoverySelect determines which IIO (or CEC) boards will dump and reboot in the event that this IIO board crashes.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER halt(1), haltSystem(2), reboot(3), rebootSystem(4), dumpAndReboot(5), selectiveDumpAndReboot(6)  

a3sysIioRecoverySelect 1.3.6.1.4.1.43.2.13.13.1.1.3
This object specifies the IIO or CEC boards that will dump and reboot in the event this IIO or CEC board crashes. This object is relevant only if the value of a3sysIioRecoveryProcedure is selectiveDumpAndReboot (6). The boards are specified by their slot. Each slot is represented by a single bit in the value of this object. If that bit is set (to 1), then that board will dump and reboot. Slot 0 is used to identify the CEC board, and corresponds to the least significant bit in this object. Slot 1 is used to identify the IIO board in that slot and corresponds to the next significant bit in this object. The identification of all other boards follows this convention.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

a3BogusDhcpSvr 100
A a3BogusDhcpSvr trap signifies that an unauthorized DHCP or BOOTP server has been detected on the network.
TRAP-TYPE