A3COM-SWITCHING-SYSTEMS-TOKEN-RING-MIB

File: A3COM-SWITCHING-SYSTEMS-TOKEN-RING-MIB.mib (13856 bytes)

Imported modules

RFC1155-SMI RFC1213-MIB RFC-1212
RFC-1215

Imported symbols

enterprises Counter IpAddress
DisplayString OBJECT-TYPE TRAP-TYPE

Defined Types

A3ComSysTokenRingPortEntry  
SEQUENCE    
  a3ComSysTokenRingPortIndex INTEGER
  a3ComSysTokenRingPortIfIndex INTEGER
  a3ComSysTokenRingPortLabel DisplayString
  a3ComSysTokenRingPortInsertStatus INTEGER
  a3ComSysTokenRingPortType INTEGER
  a3ComSysTokenRingPortMode INTEGER
  a3ComSysTokenRingPortSpeed INTEGER
  a3ComSysTokenRingPortLineErrors Counter
  a3ComSysTokenRingPortBurstErrors Counter
  a3ComSysTokenRingPortACErrors Counter
  a3ComSysTokenRingPortAbortTransErrors Counter
  a3ComSysTokenRingPortInternalErrors Counter
  a3ComSysTokenRingPortLostFrameErrors Counter
  a3ComSysTokenRingPortReceiveCongestionErrors Counter
  a3ComSysTokenRingPortFrameCopiedErrors Counter
  a3ComSysTokenRingPortTokenErrors Counter
  a3ComSysTokenRingPortSoftErrors Counter
  a3ComSysTokenRingPortHardErrors Counter
  a3ComSysTokenRingPortTransmitBeacons Counter
  a3ComSysTokenRingPortLobeWires Counter
  a3ComSysTokenRingPortRemoves Counter
  a3ComSysTokenRingPortSingles Counter
  a3ComSysTokenRingPortFreqErrors Counter
  a3ComSysTokenRingPortRingStatus INTEGER

Defined Values

a3Com 1.3.6.1.4.1.43
OBJECT IDENTIFIER    

switchingSystemsMibs 1.3.6.1.4.1.43.29
OBJECT IDENTIFIER    

a3ComSwitchingSystemsMib 1.3.6.1.4.1.43.29.4
OBJECT IDENTIFIER    

a3ComSysTokenRingPort 1.3.6.1.4.1.43.29.4.13
OBJECT IDENTIFIER    

a3ComSysTokenRingPortCount 1.3.6.1.4.1.43.29.4.13.1
The count of token ring ports managed by this agent.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

a3ComSysTokenRingPortTable 1.3.6.1.4.1.43.29.4.13.2
A list of token ring port entries. A single entry exists in this list for each token ring port managed by this agent.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    A3ComSysTokenRingPortEntry

a3ComSysTokenRingPortEntry 1.3.6.1.4.1.43.29.4.13.2.1
A token ring port entry contains information about a particular token ring port managed by this agent.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  A3ComSysTokenRingPortEntry  

a3ComSysTokenRingPortIndex 1.3.6.1.4.1.43.29.4.13.2.1.1
The index of the token ring port identified by this entry, relative to this agent.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..65535  

a3ComSysTokenRingPortIfIndex 1.3.6.1.4.1.43.29.4.13.2.1.2
The value of the MIB-II ifIndex corresponding to the token ring port identified by this entry.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..65535  

a3ComSysTokenRingPortLabel 1.3.6.1.4.1.43.29.4.13.2.1.3
An ASCII text string describing the token ring port identified by this entry.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..31)  

a3ComSysTokenRingPortInsertStatus 1.3.6.1.4.1.43.29.4.13.2.1.4
The current value of the link status for the token ring port identified by this entry.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER inserted(1), deinserted(2)  

a3ComSysTokenRingPortType 1.3.6.1.4.1.43.29.4.13.2.1.5
Specific port type description for the token ring port identified by this entry.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER rj45(1), other(2)  

a3ComSysTokenRingPortMode 1.3.6.1.4.1.43.29.4.13.2.1.6
The current mode of the port. The default mode (station) is used to connect a hub to the port. Lobe mode is used to direct connect a Token Ring station into the port. This selection can only be made on ports 1 and 2 of the module.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER station(1), lobe(2)  

a3ComSysTokenRingPortSpeed 1.3.6.1.4.1.43.29.4.13.2.1.7
The current speed of the port. The default speed is sixteenMegabit.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER fourMegabit(1), sixteenMegabit(2), sixteenMegabitETR(3)  

a3ComSysTokenRingPortLineErrors 1.3.6.1.4.1.43.29.4.13.2.1.8
This counter is incremented when a frame or token is copied or repeated by a station, the E bit is zero in the frame or token and one of the following conditions exists: 1) there is a non-data bit (J or K bit) between the SD and the ED of the frame or token, or 2) there is an FCS error in the frame.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

a3ComSysTokenRingPortBurstErrors 1.3.6.1.4.1.43.29.4.13.2.1.9
This counter is incremented when a station detects the absence of transitions for five half-bit timers (burst-five error).
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

a3ComSysTokenRingPortACErrors 1.3.6.1.4.1.43.29.4.13.2.1.10
This counter is incremented when a station receives an AMP or SMP frame in which A is equal to C is equal to 0, and then receives another SMP frame with A is equal to C is equal to 0 without first receiving an AMP frame. It denotes a station that cannot set the AC bits properly.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

a3ComSysTokenRingPortAbortTransErrors 1.3.6.1.4.1.43.29.4.13.2.1.11
This counter is incremented when a station transmits an abort delimiter while transmitting.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

a3ComSysTokenRingPortInternalErrors 1.3.6.1.4.1.43.29.4.13.2.1.12
This counter is incremented when a station recognizes an internal error.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

a3ComSysTokenRingPortLostFrameErrors 1.3.6.1.4.1.43.29.4.13.2.1.13
This counter is incremented when a station is transmitting and its TRR timer expires. This condition denotes a condition where a transmitting station in strip mode does not receive the trailer of the frame before the TRR timer goes off.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

a3ComSysTokenRingPortReceiveCongestionErrors 1.3.6.1.4.1.43.29.4.13.2.1.14
This counter is incremented when a station recognizes a frame addressed to its specific address, but has no available buffer space indicating that the station is congested.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

a3ComSysTokenRingPortFrameCopiedErrors 1.3.6.1.4.1.43.29.4.13.2.1.15
This counter is incremented when a station recognizes a frame addressed to its specific address and detects that the FS field A bits are set to 1 indicating a possible line hit or duplicate address.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

a3ComSysTokenRingPortTokenErrors 1.3.6.1.4.1.43.29.4.13.2.1.16
This counter is incremented when a station acting as the active monitor recognizes an error condition that needs a token transmitted.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

a3ComSysTokenRingPortSoftErrors 1.3.6.1.4.1.43.29.4.13.2.1.17
The number of Soft Errors the interface has detected. It directly corresponds to the number of Report Error MAC frames that this interface has transmitted. Soft Errors are those which are recoverable by the MAC layer protocols.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

a3ComSysTokenRingPortHardErrors 1.3.6.1.4.1.43.29.4.13.2.1.18
The number of times this interface has detected an immediately recoverable fatal error. It denotes the number of times this interface is either transmitting or receiving beacon MAC frames.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

a3ComSysTokenRingPortTransmitBeacons 1.3.6.1.4.1.43.29.4.13.2.1.19
The number of times this interface has transmitted a beacon frame.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

a3ComSysTokenRingPortLobeWires 1.3.6.1.4.1.43.29.4.13.2.1.20
The number of times the interface has detected an open or short circuit in the lobe data path. The adapter will be closed when this condition occurs.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

a3ComSysTokenRingPortRemoves 1.3.6.1.4.1.43.29.4.13.2.1.21
The number of times the interface has received a Remove Ring Station MAC frame request. When this frame is received the interface will enter the close state.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

a3ComSysTokenRingPortSingles 1.3.6.1.4.1.43.29.4.13.2.1.22
The number of times the interface has sensed that it is the only station on the ring. This will happen if the interface is the first one up on a ring, or if there is a hardware problem.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

a3ComSysTokenRingPortFreqErrors 1.3.6.1.4.1.43.29.4.13.2.1.23
The number of times the interface has detected that the frequency of the incoming signal differs from the expected frequency.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

a3ComSysTokenRingPortRingStatus 1.3.6.1.4.1.43.29.4.13.2.1.24
The current interface status which can be used to diagnose fluctuating problems that can occur on token rings, after a station has successfully been added to the ring. Before an open is completed, this object has the value for the 'no status' condition. This object is useful for debugging problems when the station can not even enter the ring. The object's value is a sum of values, one for each currently applicable condition. The following values are defined for various conditions: 0 = No Problems detected 32 = Ring Recovery 64 = Single Station 256 = Remove Received 512 = reserved 1024 = Auto-Removal Error 2048 = Lobe Wire Fault 4096 = Transmit Beacon 8192 = Soft Error 16384 = Hard Error 32768 = Signal Loss 131072 = no status, open not completed.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER